Attachment 0003 DWG 19-48-4116-20PA1002 dated Dec 2019.pdf
PDF 424 KB Posted
- Attached to
- Wood Packaging Components
- Solicitation number
- W519TC-26-Q-A101
About this file
This is a basic procedure drawing for unitization of boxed ammunition and components on 4-way entry pallets, issued by the U.S. Army Materiel Command under Project FSA 146-75, Drawing 19-48-4116, with the most current revision (No. 14) dated December 2019.
The drawing establishes standardized procedures and material specifications for assembling ammunition unit loads on MIL-DTL-15011 4-way entry pallets (Style 1, 1A, or 1B). Key specifications include pallet gross weight targets of 2,464 pounds optimum with a 4,000-pound maximum, unit load dimensions not exceeding 44" length by 54" width for standard pallets (with variations for different pallet styles), and maximum overall height of 54" including pallet. Material requirements encompass preservative and heat-treated lumber conforming to TM 743-200-1 and ASTM D6199 (Group IV only for pallet construction), ASTM D3953 steel strapping (3/4" or 1-1/4" flat strapping, Type 1, Heavy Duty, Grade 2, with .035", .031", or .029" thickness options), ASTM D3953 Class H strap seals, and ASTM F1667 staples. The document specifies procedures for typical unitization with load straps, horizontal straps, and tiedown straps positioned through pallet slots or deck, along with detailed provisions for less-than-full-layer unit loads using filler assemblies, empty boxes, or light boxes with specific positioning constraints and marking requirements per DAC Drawing ACV00561. General notes address box alignment tolerances (±1/2"), strap tensioning requirements, inspection and maintenance protocols, wirebound box reinforcement, wood preservative treatment per ARDEC Drawing 13064136, and ISPM-15 heat treatment certification. The drawing references applicable appendices that provide specific configurations, unitization specifications, and tabular data for individual ammunition items or item categories.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPROVED, COMBAT CAPABILITIES DEVELOPMENT
COMMAND ARMAMENTS CENTER
APPROVED, U.S. ARMY JOINT MUNITIONS COMMAND
APPROVED BY ORDER OF COMMANDING GENERAL,
U.S. ARMY MATERIEL COMMAND
U.S. ARMY DEFENSE AMMUNITION CENTER
INDEX
ITEM PAGE(S)
GENERAL NOTES AND MATERIAL SPECIFICATIONS - - - - - - - - - - - - - 2-4
TYPICAL UNITIZATION PROCEDURES - - - - - - - - - - - - - - - - - - 5-6
LESS-THAN-FULL-LAYER UNIT LOADS - - - - - - - - - - - - - - - - - - 7
DETAILS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8
TYPICAL FILLER ASSEMBLIES - - - - - - - - - - - - - - - - - - - - - 9
WALLS.DAVID.MIC
HAEL.1154540543
Digitally signed by
WALLS.DAVID.MICHAEL.115454
Date: 2020.03.05 07:12:31 -06'00'
WARD.GINA.
M.1369379808
Digitally signed by
WARD.GINA.M.1369379808
Date: 2020.03.05 08:50:30 -06'00'
FIEFFER.LAUR
A.A.1230375727
Digitally signed by
FIEFFER.LAURA.A.1230375727
Date: 2019.12.31 08:02:11 -06'00'
SMITH.THERESA.
ANN.1009147639
Digitally signed by
SMITH.THERESA.ANN.1009147
Date: 2020.03.05 11:24:41 -06'00'
FELICIANO.AD
IN.1259200373
Digitally signed by
FELICIANO.ADIN.1259200373
Date: 2020.01.09 13:58:00 -06'00'
THOMAS.CARL.ANT
HONY.1104621372
Digitally signed by
THOMAS.CARL.ANTHONY.11046
21372 Date: 2020.01.23 06:47:00 -06'00'
PROJECT FSA 146-75 DRAWING 19-48-4116
GENERAL NOTES
A. THIS DOCUMENT HAS BEEN PREPARED AND ISSUED IN ACCORDANCE WITH AR
740-1 AND AUGMENTS TM 743-200-1 (CHAPTER 5) AND CONFORMS TO MIL-STD-
1660.
B. APPROVED SPECIFICATIONS, COVERING THE ASSEMBLAGE AND UNITIZATION OF
BOX-PACKED AMMUNITION INTO UNIT LOADS, ARE SET FORTH IN THIS DRAWING.
THIS DRAWING WILL BE CONSIDERED THE BASIC DOCUMENT FOR THE UNITIZA-
TION OF AMMUNITION ITEMS PACKED IN BOXES, EXCEPT FOR SOME RESTRICT-
ED ITEMS, SUCH AS WP FILLED AMMUNITION. THIS DOCUMENT INCLUDES MA-
TERIAL SPECIFICATIONS AND UNITIZING STANDARDS APPLICABLE TO UNITIZA-
TION, PLUS INFORMATION RELATIVE TO TYPICAL POSITIONING OF BOXES ON A
PALLET AND INSTALLATION OF UNITIZING STEEL STRAPPING. FOR TYPICAL
UNITIZATION PROCEDURES SEE PAGES 5 AND 6. ADDITIONALLY, PROCEDURES
FOR LESS-THAN-FULL-LAYER UNIT LOADS ARE DELINEATED ON PAGE 7.
C. APPENDICES PERTAINING TO THIS BASIC DOCUMENT WILL BE ISSUED SEPA-
RATELY. ALL APPENDICES, HOWEVER, ARE A PART OF THIS BASIC PROCEDURE
DRAWING. EACH APPENDIX WILL COVER THE APPROVED CONFIGURATION FOR
A UNIT LOAD, THE SPECIFIC UNITIZATION SPECIFICATIONS AND THE PERTINENT
TABULAR DATA FOR ONE ITEM OF AMMUNITION OR FOR A CATEGORY OF AM-
MUNITION ITEMS.
D. GENERALLY, UNIT LOADS SHOWN IN THE APPENDICES WILL CONFORM TO THE
STANDARDS LISTED BELOW.
1. GROSS WEIGHTS OF PALLETIZED UNIT LOADS ARE BASED ON AN OPTIMUM
WEIGHT OF 2,464 POUNDS, DUE TO MATERIAL HANDLING EQUIPMENT CON-
SIDERATIONS. UNLESS SPECIFICALLY RESTRICTED BY ANOTHER AUTHORI-
TATIVE DOCUMENT, THE MAXIMUM GROSS WEIGHT OF AMMUNITION UNIT
LOADS IS 4,000 POUNDS.
2. UNIT LOADS SHOULD NOT EXCEED 44" IN LENGTH BY 54" IN WIDTH FOR
STYLE 1 (40" X 48") PALLETS, 39" IN LENGTH BY 51-1/2" IN WIDTH FOR STYLE
1A (35" X 45-1/2") PALLETS, OR 44" IN LENGTH BY 59" IN WIDTH FOR STYLE 1B
(42" X 53") PALLETS. UNIT LOAD HEIGHT, INCLUDING PALLET HEIGHT,
SHOULD NOT EXCEED 54". ANY OR ALL OF THE STATED DIMENSIONS FOR
THE LENGTH, WIDTH OR HEIGHT OF A UNIT LOAD, HOWEVER, CAN BE IN-
CREASED OR DECREASED, DEPENDING UPON PECULIARITIES OF THE COM-
MODITY BEING UNITIZED AND IDENTIFIABLE FACTORS THAT INFLUENCE TO-
TAL COST EFFECTIVENESS THROUGHOUT THE AMMUNITION LOGISTICS SYS-
TEM.
3. THE UNIT LOAD SHOULD EITHER BE FLUSH WITH OR SLIGHTLY OVERHANG
THE PALLET ON ALL FOUR SIDES. OVERHANG IS DEFINED AS THE DISTANCE
THAT THE AMMUNITION ITEM PACKAGE(S) EXTENDS BEYOND THE EDGE OF
THE PALLET. WHEN THE EDGE OF THE AMMUNITION ITEM PACKAGE(S) DOES
NOT REACH THE EDGE OF THE PALLET, SPACER ASSEMBLIES OR BATTENS
WILL BE POSITIONED WITHIN THE UNIT LOAD IN ACCORDANCE WITH SPECIFI-
CATIONS OF THE APPLICABLE APPENDIX AND AS TYPICALLY SHOWN ON
PAGE 6. SEE GENERAL NOTE "V" ON PAGE 3.
(CONTINUED AT RIGHT)
MATERIAL SPECIFICATIONS
PALLET - - - - - - -: MIL SPEC MIL-DTL-15011; 4-WAY ENTRY, STYLE 1,
1A OR 1B, TYPE I, CLASS 1, PRESERVATIVE AND
HEAT TREATED.
LUMBER - - - - - - -: SEE TM 743-200-1 (DUNNAGE LUMBER) AND VOLUNTARY
PRODUCT STANDARD PS 20 FOR FILLER ASSEMBLIES.
ASTM D 6199; CLASS 2, GROUP II, III, OR IV,
PRESERVATIVE AND HEAT TREATED FOR OTHER DUNNAGE
ASSEMBLIES. NOTE: ONLY GROUP IV LUMBER IN AC-
CORDANCE WITH ASTM D6199 WILL BE ACCEPTABLE FOR
THE CONSTRUCTION OF THE PALLET. SEE GENERAL
NOTES "AA" ON PAGE 3 AND “JJ” ON PAGE 4.
NAILS - - - - - - -: ASTM F1667; COMMON STEEL NAIL (NLCMS OR
NLCMMS). ALT: UNDERLAYMENT NAIL (NLUL), PAL-
LET NAIL (NLPL), OR COOLER NAIL (NLCL) OF SAME
SIZE. SEE GENERAL NOTE "GG" ON PAGE 4.
PLYWOOD - - - - - -: COMMERCIAL ITEM DESCRIPTION A-A-55057, INDUS-
TRIAL PLYWOOD, INTERIOR WITH EXTERIOR GLUE,
GRADE C-D. IF SPECIFIED GRADE IS NOT AVAILA-
BLE, A BETTER INTERIOR OR AN EXTERIOR GRADE MAY
BE SUBSTITUTED.
STRAPPING, STEEL - -: ASTM D3953; FLAT STRAPPING, TYPE 1, HEAVY DUTY,
FINISH B (GRADE 2), SIZE 3/4" X .035" OR .031"
OR .029”. ALTERNATIVE SIZE 1-1/4" X .035" OR
.031" OR .029”. NOTE: IF EDGES DO NOT MEET
THE PREECE TEST FOR GRADE 2, ANY BRITE OR SLIT
EDGES MUST HAVE FINISH A OVERLAY APPLIED.
SEAL, STRAP - - - -: ASTM D3953; CLASS H, FINISH B (GRADE 2), DOUBLE
NOTCH TYPE, STYLE I, II, III, OR IV. ALTERNA-
TIVE SEAL FINISH: SIGNODE OR DELTA PAINTED
SEALS MAY BE USED AS AN ALTERNATIVE IF ALL SUR-
FACES ARE PAINTED. GRITTED BACKING IS NOT PER-
MITTED.
STAPLE, STRAP - - -: ASTM F1667; STFCS-189, STFCS-198, STFCS-207, OR
STFCS-216, 15/16" OR 1" CROWN WIDTH X 3/4" LEG
LENGTH FOR 3/4" STRAPPING OR STFCS-224,
1-17/32" CROWN WIDTH X 3/4" LEG LENGTH FOR
1-1/4" STRAPPING. SEE GENERAL NOTE “P” ON PAGE
3.
(GENERAL NOTES CONTINUED)
4. AN AMMUNITION BOX (EXTERIOR PACK) WILL NOT CONTAIN MORE THAN ONE
LOT OF AMMUNITION PER BOX. UNIT LOADS WILL NOT CONTAIN MORE THAN
TWO LOTS PER UNIT LOAD, EXCEPT WHERE REQUIRED FOR BALLISTIC SAM-
PLE SHIPMENT OR FOR TROOP USE AT POST, CAMP OR STATION. SEE GEN-
ERAL NOTE "R" ON PAGE 3, AND GENERAL NOTE "DD" ON PAGE 4 FOR ADDI-
TIONAL GUIDANCE.
5. LESS-THAN-FULL BOXES OF AN AMMUNITION ITEM (LIGHT BOXES) ARE LIM-
ITED TO ONLY ONE LIGHT BOX PER ITEM LOT. A UNIT LOAD WILL NOT CON-
TAIN MORE THAN ONE LIGHT BOX PER ITEM LOT ON A PALLET. ADDITIONAL
REQUIREMENTS ARE SPECIFIED IN THE "PROVISIONS FOR LESS-THAN-FULL-
LAYER UNIT LOADS" ON PAGE 7.
6. A UNIT LOAD, SUCH AS THE LAST UNIT LOAD FOR AN AMMUNITION LOT, CAN
BE ASSEMBLED WITH LESS LAYERS THAN SPECIFIED FOR THE BASIC UNIT
LOAD. THE UNIT LOAD CAN ALSO BE ASSEMBLED WITH A PARTIAL TOP LAY-
ER PROVIDING IT IS TO BE SHIPPED WITHIN CONUS TO A DEPOT, DEPOT AC-
TIVITY, POST, CAMP, OR STATION. FOR OCONUS OR FOREIGN MILITARY
SALES (FMS) SHIPMENTS, HOWEVER, THE UNIT LOAD MUST NOT BE ASSEM-
BLED WITH A PARTIAL LAYER. EMPTY BOXES OR FILLER ASSEMBLIES WILL
BE USED TO ACHIEVE FULL-LAYER CONFIGURATION. FOR ADDITIONAL GUID-
ANCE, SEE GENERAL NOTE "F" AND THE "LESS-THAN-FULL LAYER UNIT
LOADS" PROCEDURES ON PAGE 7.
E. ANY REQUEST FOR DEVIATION FROM THE STANDARDS DESCRIBED IN GENERAL
NOTE “D” OR FROM THE PROCEDURES DELINEATED IN AN APPENDIX MUST BE
DIRECTED TO THE COMMANDER, COMBAT CAPABILITIES DEVELOPMENT COM-
MAND ARMAMENTS CENTER, ATTN: CFDD-ACE-LTP, ROCK ISLAND, IL 61299-7300,
FOR SPECIFIC APPROVAL. FOR EXAMPLE, SPECIFIC APPROVAL MUST BE OB-
TAINED FOR UNITIZATION OF AN ITEM WHEN PACKED IN BOXES WHICH ARE DIF-
FERENT IN SIZE THAN THOSE SHOWN IN THE APPENDIX FOR THAT ITEM, EVEN
THOUGH THE UNIT LOAD MAY COMPLY WITH THE STANDARDS DESCRIBED IN
GENERAL NOTE “D”.
F. EXCEPT AS OTHERWISE STATED WITHIN GENERAL NOTE "D.6" ABOVE, UNIT
LOADS MUST ONLY BE MADE UP WITH FULL LAYERS. FOR REDUCED QUANTI-
TIES, HOWEVER, ONE OR MORE FULL LAYERS MAY BE OMITTED, AND/OR A FULL
LAYER MAY CONSIST OF BOXED ITEMS AND A FILLER ASSEMBLY OR AN EMPTY
BOX(ES). SEE THE PROVISIONS FOR "LESS-THAN-FULL-LAYER UNIT LOADS" ON
PAGE 7. ONLY ONE UNIT LOAD HAVING A REDUCED QUANTITY OF ITEMS
SHOULD BE PERMITTED PER LOT OF THAT ITEM. EACH LAYER OF BOXES WILL
BE POSITIONED SO AS TO BE CENTERED LENGTHWISE AND WIDTHWISE ON THE
DECK OF THE PALLET. CARE SHALL BE TAKEN TO INSURE THAT THE BOXES ARE
EVENLY ALIGNED HORIZONTALLY AND VERTICALLY SO THAT THE SIDES AND
ENDS OF THE UNIT LOAD DO NOT EXCEED A 1/2" TOLERANCE, RELATIVE TO THE
PALLET DECK. SEE THE “ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS”
DETAILS ON PAGE 8. ALSO, SEE GENERAL NOTE "W" ON PAGE 3 AND THE TYPI-
CAL FILLER ASSEMBLIES ON PAGE 9.
G. GENERALLY, WHEN UNITIZING BOXES WITH TOP CLEATS, BOXES WILL BE POSI-
TIONED ON THE UNIT LOAD WITH CLEATS UPWARD. IF BOXES ARE OF THE
HINGED-TOP TYPE, THE OUTSIDE BOXES IN THE TOP LAYER WILL BE POSI-
TIONED SO THAT THE HINGES WILL BE INWARD. CAUTION: ROCKETS AND
ROCKET MOTORS IN A PROPULSIVE STATE WILL BE POSITIONED IN THE UNIT
LOAD WITH ALL NOSE ENDS IN ONE DIRECTION. UNIT LOAD STRAPS, IN THESE
INSTANCES, MAY PASS OVER HINGES OF BOXES. ALSO, SEE GENERAL NOTE
"BB" ON PAGE 3.
H. A PLUS-OR-MINUS 1/4" IS ALLOWED ON OVERALL DIMENSIONS OF A FILLER AS-
SEMBLY, SPACER ASSEMBLY OR ANY OTHER DUNNAGE ASSEMBLY. HOWEVER,
SIMILAR PIECES IN AN ASSEMBLY MUST BE WITHIN 1/8" OF THE SAME DIMEN-
SION.
J. DIMENSIONAL LUMBER SPECIFIED THROUGHOUT THIS PROCEDURAL DRAWING
IS OF NOMINAL SIZE UNLESS OTHERWISE SPECIFIED. FOR EXAMPLE, 1" X 4" MA-
TERIAL IS ACTUALLY 3/4" THICK BY 3-1/2" WIDE AND 2" X 4" MATERIAL IS ACTUAL-
LY 1-1/2" THICK BY 3-1/2" WIDE.
K. IN ORDER TO OBTAIN COMPACT (SOUND) UNITS, ALL STRAPS SHALL BE LOCAT-
ED IN PROPER ALIGNMENT AND TENSIONED UNTIL THEY CUT INTO THE EDGE OF
THE BOXES AND/OR THE PALLET DECK. AFTER TENSIONING, EACH STRAP WILL
BE SECURED USING ONE SEAL AND TWO PAIR OF NOTCHES PER SEAL. SEE
"ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS" DETAILS ON PAGE 8.
SEALS MAY BE LOCATED ON A SIDE OR ON THE TOP OF THE UNIT, AS REQUIRED
BY OPERATIONAL NECESSITY. ALSO, SEE GENERAL NOTE "HH" ON PAGE 4 FOR
ACCEPTABLE SEALLESS OR CLIPLESS TOOL INFORMATION.
L. WHEN APPLYING ANY STRAP, CARE MUST BE EXERCISED TO ASSURE THAT THE
END OF THE STRAP ON THE UNDERSIDE OF THE JOINT EXTENDS AT LEAST 6"
BEYOND THE SEAL. THIS EXTRA MINIMUM LENGTH OF THE STRAP IS REQUIRED
TO PERMIT SUBSEQUENT TIGHTENING OF LOOSENED STRAPPING. RETENSION-
ING CAN BE ACCOMPLISHED WITHOUT REPLACING STRAPPING OR SPLICING
STRAPPING THROUGH THE USE OF A MANUAL OR PNEUMATIC FEEDWHEEL
TYPE TENSIONING TOOL AND THE APPLICATION OF ONE ADDITIONAL SEAL. SEE
"STRAP RETENSIONING TAB" VIEW ON PAGE 5.
(CONTINUED ON PAGE 3)
PROJECT FSA 146-75DRAWING 19-48-4116
(GENERAL NOTES CONTINUED FROM PAGE 2)
M. DETERMINATION OF LENGTH OF STRAPPING. THE FOLLOWING DEFINITIONS
APPLY:
L = LENGTH OF STRAP REQUIRED IN INCHES
A = LENGTH OF UNIT IN INCHES
W = WIDTH OF UNIT IN INCHES
H = HEIGHT OF UNIT, INCLUDING PALLET, IN INCHES
1. THE LENGTH OF A LOAD STRAP REQUIRED FOR A SPECIFIC UNIT, WHERE
THE STRAP PASSES THROUGH THE STRAP SLOT OR ABOVE THE PALLET
DECK, WILL BE DETERMINED BY USING THE FOLLOWING FORMULA:
L = 2W + 2H + 2".
2. THE LENGTH OF A HORIZONTAL STRAP REQUIRED FOR A SPECIFIC UNIT,
WHERE THE STRAP ENCIRCLES THE UNIT LOAD, WILL BE DETERMINED BY
USING THE FOLLOWING FORMULA: L = 2A + 2W + 12".
3. THE LENGTH OF A TIEDOWN STRAP REQUIRED FOR A SPECIFIC UNIT,
WHERE THE STRAP PASSES UNDER THE PALLET DECK, WILL BE DETER-
MINED BY USING THE FOLLOWING FORMULA: L = 2A + 2H + 2".
N. PALLET UNIT LOADS SHALL BE INSPECTED FOR TORN, DETERIORATED OR
LOOSENED STRAPPING PRIOR TO SHIPPING.
1. TORN OR BROKEN STRAPS SHOULD BE REPLACED BY CONTRACTORS,
BUT MAY BE REPAIRED AT THE DEPOT/FIELD LEVEL BY SPLICING IN A
MANNER SIMILAR TO THAT DESCRIBED IN “N.4(B)” BELOW.
2. DETERIORATION DUE TO A MINOR AMOUNT OF RUST WILL NOT NECES-
SARILY BE CAUSE FOR REPLACING A STRAP. HOWEVER, AN EXTENSIVELY
RUSTED/SCALED/PITTED STRAP IS CAUSE FOR REPLACING THE STRAP.
3. A DAMAGED OR DEFECTIVE SEAL IS SUFFICIENT CAUSE FOR REPLACE-
MENT OF THE SEAL.
4. LOOSE STRAPS SHOULD BE CHECKED FOR DEGREE OF LOOSENESS BY
POSITIONING THE HOOK OF A SCALE (COMMONLY KNOWN AS A FISH
SCALE) BEHIND THE STRAPS NEAR THE MIDPOINT AT THE TOP OR SIDE OF
THE UNIT LOAD. PULL THE SCALE UNTIL A READING OF 20 POUNDS IS OB-
TAINED. THE DISTANCE BETWEEN THE BOX AND THE STRAP MUST NOT
EXCEED 1-1/2". IF MEASUREMENT EXCEEDS 1-1/2", THE STRAP MUST BE
TIGHTENED OR REPLACED. SEE PAGE 5 FOR GUIDANCE. TIGHTENING
CAN BE ACCOMPLISHED BY EITHER OF TWO METHODS.
(A) A STRAP TENSIONING TOOL CAN BE USED IF THE STRAP HAS AT
LEAST A 6" LONG TAB AT THE SEAL. SEE GENERAL NOTE "L" ON PAGE
2.
(B) AN 18" OR LONGER STRAP CAN BE USED AS A SPLICE PIECE. CUT THE
LOOSE STRAP ON BOTH SIDES OF THE ORIGINAL SEAL AND DISCARD
THE CUT OUT SECTION. OVERLAP ONE END OF THE STRAP SPLICE
PIECE TO ONE END OF THE ORIGINAL STRAPPING SO AS TO PRO-
TRUDE SLIGHTLY BEYOND THE END OF THE SEAL TO BE USED. POSI-
TION AND SECURE SEAL TO OVERLAPPED SECTION WITH TWO PAIR
OF NOTCHES. USING A STRAPPING TOOL, TENSION AND SEAL THE
LENGTHENED STRAP. THE STRAP SPLICE PIECE MAY BE CUT FROM
NEW STRAP OR USED STRAP, PROVIDED IT IS AT LEAST OF AS GOOD
A QUALITY AS THE STRAP TO WHICH IT IS BEING SECURED. NOTE:
ONLY ONE SPLICE PER STRAP IS ALLOWED ON UNIT LOADS OF AM-
MUNITION.
5. CAUTION: WHEN A STRAP IS REPLACED/SPLICED OR RETENSIONED, AND
THE OTHER STRAPS ON A UNIT LOAD ARE NOT, CARE MUST BE EXER-
CISED TO INSURE THAT THE TENSION ON THE AFFECTED STRAP IS NEAR-
LY THE SAME AS THAT OF THE OTHER STRAPS.
O. AMMUNITION UNITIZED PRIOR TO DISTRIBUTION OF THIS DRAWING OR OF AN
APPENDIX THERETO, NEED NOT BE REUNITIZED SOLELY TO CONFORM TO
THE STANDARDS SPECIFIED HEREIN OR TO THE METHOD SHOWN IN AN AUG-
MENTING APPENDIX. HOWEVER, BOX AND STRAP ALIGNMENT MUST CON-
FORM TO THE TOLERANCE STANDARDS SPECIFIED ON PAGE 8 OF THIS
DRAWING BEFORE A UNIT IS ACCEPTABLE FOR SHIPMENT. ALSO, THE CON-
DITION OF THE UNITIZING STRAPPING ON A UNIT LOAD MUST COMPLY WITH
THE CRITERIA OF GENERAL NOTE "N" ABOVE.
P. ROOFING NAILS IN ACCORDANCE WITH ASTM F1667 NL RF R-02Z MAY BE
USED AS AN ALTERNATE TO STAPLES FOR SECURING STEEL STRAPS TO
BOARDS. NAILS MUST BE APPLIED NEXT TO THE STRAPPING SUCH THAT THE
NAIL HEADS OVERLAP THE STRAPPING. APPLY TWO NAILS IN PAIRS (TO RE-
PLACE ONE STAPLE) ON EITHER SIDE OF THE STRAP, WITH THE SECOND NAIL
APPLIED APPROXIMATELY 180 DEGREES FROM THE FIRST NAIL.
Q. UNIT LOAD MARKING WILL BE ACCOMPLISHED IN ACCORDANCE WITH DAC
DRAWING ACV00561, UNIT LOAD MARKING FOR SHIPMENT AND STORAGE,
AMMUNITION AND EXPLOSIVES.
R. IF THE REQUISITION QUANTITY IN SUPPORT OF AN AMMUNITION SHIPMENT IS
LESS THAN A FULL LAYER QUANTITY OF BOXES FOR A UNIT LOAD, THE BOXES
NEED NOT BE PALLETIZED FOR SHIPMENT. THE BOXES MAY BE PALLETIZED,
HOWEVER, FOR ENHANCED HANDLING, CLASSIFIED/SENSITIVE ITEM CONSID-
ERATIONS, ETC., BUT DO NOT REQUIRE FILLER ASSEMBLIES TO COMPLETELY
FILL OUT THE PALLET. NOTE THAT THE METHOD FOR BRACING AND STAYING
ON THE LOOSE OR PALLETIZED BOXES MUST COMPLY WITH THE METHODS
SPECIFIED WITHIN THE APPLICABLE 19-48 SERIES OUTLOADING PROCEDURAL
DRAWING.
(CONTINUED AT RIGHT)
(GENERAL NOTES CONTINUED)
S. OUTLOADING AND STORAGE OF PALLET UNITS SHALL BE ACCOMPLISHED IN
ACCORDANCE WITH APPLICABLE PROCEDURAL DRAWINGS AS IDENTIFIED IN
THE APPENDICES FOR SPECIFIC UNITS. THESE DRAWINGS ARE AVAILABLE
AT HTTPS://WWW.DAU.EDU/COP/AMMO/PAGES/DEFAULT.ASPX. CONTACT THE
DEFENSE AMMUNITION CENTER AT THE ABOVE WEB ADDRESS IF SPECIFIC
STORAGE AND OUTLOADING DRAWINGS ARE NOT IDENTIFIED WITHIN A PAR-
TICULAR APPENDIX.
T. CONVERSION TO METRIC EQUIVALENTS: DIMENSIONS WITHIN THIS DOCU-
MENT ARE EXPRESSED IN INCHES, AND WEIGHTS ARE EXPRESSED IN
POUNDS. WHEN NECESSARY, THE METRIC EQUIVALENTS MAY BE COMPUTED
ON THE BASIS OF ONE INCH EQUALS 25.4MM AND ONE POUND EQUALS 0.454
KG.
U. WHEN ASSEMBLING A COMPLETE PALLET UNIT, CARE SHALL BE TAKEN TO
INSURE THAT THE AMMUNITION ITEM PACKAGES AND DUNNAGE ASSEMBLIES,
AS APPLICABLE, ARE EVENLY ALIGNED SO THAT THE SIDES AND ENDS OF
THE PALLET UNIT DO NOT EXCEED A 1/2" TOLERANCE, RELATIVE TO THE PAL-
LET. SEE THE "ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS" DETAILS
ON PAGE 8.
V. A SPACER ASSEMBLY WILL BE DESIGNED SO THAT BOXES ON EACH SIDE OF
A VOID WITHIN A UNIT LOAD WILL BE BRACED AS STRONGLY AS IF THE VOID
WAS OCCUPIED BY THE BOXES THAT MAKE UP THE UNIT LOAD. ALSO, A
SPACER ASSEMBLY WILL BE DESIGNED IN A MANNER THAT WILL PREVENT
DAMAGE TO ADJACENT BOXES. GENERALLY, VERTICAL PIECES OF AN AS-
SEMBLY WILL BE INSTALLED AT THE OUTER EDGES OF A UNIT LOAD AND AT
LOCATIONS TO BE CENTERED ON ALL VERTICAL JOINTS BETWEEN ADJACENT
STACKS. ADDITIONALLY, AS GENERAL GUIDANCE, HORIZONTAL PIECES OF
AN ASSEMBLY WILL BE INSTALLED AT THE TOP AND BOTTOM OF THE TOP
AND BOTTOM LAYERS, RESPECTIVELY, AND AT LOCATIONS TO BE CENTERED
ON ALL HORIZONTAL JOINTS BETWEEN LAYERS. WHEN A SPACER ASSEMBLY
IS REQUIRED TO BE USED WITHIN A UNIT LOAD, THE CONSTRUCTION SPECI-
FICATIONS AND DETAIL WILL BE PROVIDED WITHIN THE APPLICABLE APPEN-
DIX FOR THE ITEM TO BE UNITIZED.
W. FILLER ASSEMBLIES ARE DESIGNED SO AS TO PROVIDE LATERAL AND LONGI-
TUDINAL BRACING WITHIN THE UNIT LOAD EQUIVALENT TO OR GREATER
THAN THE STRENGTH OF THE BOX(ES) BEING OMITTED FROM A LAYER.
WHEN A FILLER ASSEMBLY IS REQUIRED TO BE USED WITHIN A UNIT LOAD,
THE CONSTRUCTION SPECIFICATIONS AND DETAILS WILL BE PROVIDED IN
THE APPLICABLE APPENDIX FOR THE ITEM TO BE UNITIZED. SEE THE TYPI-
CAL FILLER ASSEMBLIES ON PAGE 9.
X. WHEN UNITIZING ITEMS PACKED IN WIREBOUND BOXES, AN END CLEAT OF A
BOX MAY BREAK OR BECOME DEFORMED TO AN UNACCEPTABLE DEGREE
DUE TO STRAP TENSIONING. IN THE INITIAL ASSEMBLY OF A UNIT LOAD AT A
FACILITY, SUCH AS A MANUFACTURING PLANT, A BOX WITH A BROKEN OR
BADLY DEFORMED END CLEAT WILL BE REPLACED AND THE UNIT RE-
STRAPPED AS REQUIRED. IF IT IS IMPOSSIBLE TO INSTALL A UNITIZING
STRAP NEAR A BOX END CLEAT, A 1" X 3" FILLER BLOCK MAY BE PLACED UN-
DER A STRAP TO PROVIDE ADDITIONAL STRENGTH FOR THE BOX. THE FILLER
BLOCK LENGTH WILL BE CUT-TO-FIT BETWEEN OPPOSITE CLEATS, AND IT
WILL BE SECURED TO THE STRAP WITH TWO STAPLES. DUNNAGE GRADE OR
A BETTER GRADE LUMBER CAN BE USED FOR FILLER BLOCKS. IF DURING
HANDLING, OUTLOADING OR STORAGE OPERATIONS A UNIT LOAD IS FOUND
WITH A BOX WHICH HAS A BROKEN OR DEFORMED END CLEAT AND A RE-
PLACEMENT BOX IS NOT AVAILABLE OR IT IS DEEMED IMPRACTICAL TO RE-
PLACE THE BOX, AN ACCEPTABLE "FIX" CAN BE ACCOMPLISHED BY USING A
FILLER BLOCK AS SPECIFIED ABOVE. INSERT A BLOCK BETWEEN CLEATS AT
THE BREAK OR DEFORMATION. RETENSION EXISTING STRAPPING IF POSSI-
BLE OR INSTALL NEW STRAPPING AS REQUIRED. SEE THE "SPECIAL REIN-
FORCEMENT FOR WIREBOUND BOXES" DETAIL ON PAGE 5.
Y. WHEN UNITIZING ITEMS PACKED IN WIREBOUND BOXES, ALLOWABLE OVER-
HANG FOR THE BOXES IS AS FOLLOWS: WIREBOUND BOXES CONTAINING
RECTANGULAR METAL CONTAINERS AS INNER PACKS CAN OVERHANG THE
PALLET AS SPECIFIED IN GENERAL NOTE "D" ON PAGE 2. WIREBOUND BOXES
WITH INNER PACKS OTHER THAN RECTANGULAR METAL CONTAINERS WILL
NOT OVERHANG THE PALLET IN EXCESS OF ONE-HALF THE THICKNESS OF
THE BATTENS OR END CLEATS OF THE BOX, UNLESS SUPPORTED BY DUN-
NAGE MATERIAL FASTENED TO THE PALLET DECK, OR AS SPECIFIED WITH A
SEPARATELY ISSUED APPENDIX.
Z. DIMENSIONS GIVEN FOR DUNNAGE ASSEMBLIES WILL BE FIELD CHECKED
PRIOR TO THEIR ASSEMBLY. THIS GUIDANCE MUST BE APPLIED PRIOR TO
BEGINNING A PALLETIZING OPERATION. ALSO, DUE TO VARIATIONS OF
PACKAGE DIMENSIONS, ADJUSTMENTS MAY BE REQUIRED AS TO THE LOCA-
TION OF CERTAIN PIECES ON DUNNAGE ASSEMBLIES. THESE ASSEMBLIES
SHALL NOT PROTRUDE PAST THE TOP AND/OR SIDES OF THE BOXES.
AA. ALL WOODEN DUNNAGE USED IN UNIT LOADS SHALL BE TREATED WITH EI-
THER TYPE I OR TYPE III WOOD PRESERVATIVE, IN ACCORDANCE WITH
ARDEC DRAWING 13064136. IF THE DUNNAGE CONSISTS OF MORE THAN ONE
COMPONENT, IT MUST BE ASSEMBLED PRIOR TO TREATMENT. PRESERVATIVE
MARKING SHALL BE APPLIED TO AT LEAST ONE LOCATION ON THE ASSEMBLY
OR COMPONENT IN ACCORDANCE WITH PARAGRAPH 3.3.6 OF ARDEC DRAW-
ING 13064136.
BB. WHEN UNITIZING BOXES WITH TOP CLEATS AND THE BOXES ARE POSITIONED
ON THEIR SIDES, THE BOXES LOCATED IN THE OUTER STACKS MUST HAVE
THE TOP CLEATS TURNED INWARD, EXCEPT AS OTHERWISE SPECIFIED IN
DAC DRAWING ACV00561.
(CONTINUED ON PAGE 4)
(GENERAL NOTES CONTINUED FROM PAGE 3)
CC. WHERE 3/4" UNITIZING STEEL STRAPPING IS SPECIFIED FOR USE BY AN APPEN-
DIX THAT AUGMENTS THIS DRAWING, 1-1/4" STRAPPING MAY BE SUBSTITUTED
FOR THE 3/4" STRAPPING, PROVIDED THAT TWO BASIC REQUIREMENTS ARE
SATISFIED. ALL OF THE SPECIFICATION CRITERIA SET FORTH UNDER THE "MA-
TERIAL SPECIFICATIONS" FOR THE 3/4" STRAPPING AND STRAP SEALS WILL BE
USED FOR THE 1-1/4" STRAPPING AND SEALS, EXCEPT FOR THE SIZE CRITERION.
APPROVAL TO USE THE ALTERNATIVE MATERIALS MUST BE ACQUIRED IN AC-
CORDANCE WITH THE GUIDANCE SET FORTH BY GENERAL NOTE "E" ON PAGE 2
PRIOR TO USING THE 1-1/4" STRAPPING AND SEALS. NOTICE: REQUESTS TO
USE SUBSTITUTE MATERIALS MUST BE HANDLED ON A CASE BY CASE BASIS. AN
APPROVAL TO USE 1-1/4" MATERIALS IS NOT A BLANKET APPROVAL TO ALL AP-
PENDICES.
DD. GENERAL NOTE "D.4" ON PAGE 2 SPECIFIES THAT NO MORE THAN TWO LOTS OF
AMMUNITION WILL BE CONTAINED ON A PALLET UNLESS IN SUPPORT OF BALLIS-
TIC SAMPLE SHIPMENT OR TROOP USE AT POST, CAMP, OR STATION. THIS IS
INTENDED TO BE APPLIED TO PALLETIZING OPERATIONS BEING PERFORMED AT
A LOAD, ASSEMBLE AND PACK PLANT OR TO MAJOR MAINTENANCE OPERATIONS
BEING PERFORMED AT AN AMMUNITION DEPOT WHEN THE QUANTITY OF BOXES
COMPRISING A LOT IS GREAT ENOUGH TO CONSTRUCT MORE THAN ONE PALLET
UNIT. NOTICE: MULTIPLE (MORE THAN TWO) LOTS ARE PERMITTED TO BE PAL-
LETIZED TOGETHER AS A UNIT LOAD WHEN A SINGLE LOT QUANTITY IS INSUFFI-
CIENT TO COMPLETE ONE FULL-SIZE OR REDUCED-LAYER (TO SATISFY A SMALL-
QUANTITY SHIPMENT) UNIT LOAD. ADDITIONALLY, MULTIPLE LOTS ON A PALLET
MAY CONSIST OF ONE OR MORE NSNS, PROVIDED ALL ITEMS ARE COMPATIBLE
AND THEY ARE BEING SHIPPED TO A SINGLE CONUS POST, CAMP OR STATION.
PALLETS CONTAINING MULTIPLE NSNS WILL NOT BE SHIPPED TO CONUS OR
OCONUS DEPOTS. MULTIPLE NSN PALLET UNITS WILL HAVE STEEL STRAPPING
APPLIED SIMILAR TO PALLET STRAPPING GUIDANCE CONTAINED IN THE APPLI-
CABLE ITEM APPENDIX. ALL ITEM BOXES ON THE PALLET MUST BE RESTRAINED
IN SUCH A MANNER TO PROVIDE A SAFE, SECURE, AND COMPACT PALLET UNIT
FOR SHIPMENT. MULTIPLE LOT/NSN UNIT LOADS WILL BE MARKED IN ACCORD-
ANCE WITH DAC DRAWING ACV00561.
EE. TWO METHODS ARE APPROVED FOR DETERMINING THE AVERAGE WEIGHT THAT
IS TO BE SHOWN ON PALLETIZED UNITS OF AMMUNITION THAT ARE BEING PRO-
DUCED AT LOAD, ASSEMBLE AND PACK PLANTS.
1. PREFERRED METHOD: RANDOMLY SELECT FIVE UNIT LOADS FROM THE
CURRENT MONTH'S PRODUCTION. WEIGH EACH UNIT LOAD. THE CALCU-
LATED AVERAGE WEIGHT OF THE FIVE UNIT LOADS (TOTAL WEIGHT OF THE
FIVE UNIT LOADS DIVIDED BY FIVE) WILL BE USED AS THE UNIT LOAD WEIGHT
FOR WHICHEVER IS LESS, EITHER A 60-DAY PERIOD OR UNTIL A DIMENSION-
AL OR CONFIGURATION CHANGE IS MADE TO THE UNIT LOAD.
2. ALTERNATIVE METHOD: RANDOMLY SELECT AND WEIGH FIVE GROUPS OF
UNIT LOAD COMPONENTS (PALLET, STRAPPING, SEALS, SPACER ASSEM-
BLIES, BATTENS, ETC.) FROM THE CURRENT MONTH'S PRODUCTION AND
ADDING TO IT THE WEIGHT OF THE LOADED BOXES TO BE PLACED ON THE
PALLET. THE WEIGHT OF THE LOADED BOXES WILL BE DETERMINED BY US-
ING THE FOLLOWING PROCEDURES:
(A) WEIGH FIVE LOADED BOXES INDIVIDUALLY AND RECORD THE TOTAL
WEIGHT.
(B) WEIGH THREE INDIVIDUAL GROUPS OF FIVE LOADED BOXES EACH AND
RECORD EACH GROUP WEIGHT.
(C) WEIGH THREE INDIVIDUAL GROUPS OF TEN LOADED BOXES EACH AND
RECORD EACH GROUP WEIGHT.
(D) TOTAL ALL RECORDED WEIGHTS AND DIVIDE BY 50. THE RESULT IS THE
APPROVED LOADED BOX GROSS WEIGHT.
THE APPROVED LOADED BOX GROSS WEIGHT WILL THEN BE MULTIPLIED BY THE
QUANTITY OF BOXES TO BE PLACED ON THE PALLET AND ADDED TO EACH
GROUP OF UNIT LOAD COMPONENTS. THE CALCULATED AVERAGE WEIGHT OF
THE FIVE UNIT LOAD GROUPS (TOTAL WEIGHT OF THE FIVE UNIT LOAD GROUPS
DIVIDED BY FIVE) WILL BE USED AS THE UNIT LOAD WEIGHT FOR WHICHEVER IS
LESS, EITHER A 60-DAY PERIOD OR UNTIL A DIMENSIONAL OR CONFIGURATION
CHANGE IS MADE TO THE UNIT LOAD.
FF. WHEN UN PERFORMANCE ORIENTED PACKAGING (POP) MARKING IS REQUIRED
ON BOXES, THIS MARKING WILL SHOW IN AT LEAST ONE PLACE ON THE UNIT-
IZED LOADS.
GG. COOLER NAILS MAY BE SUBSTITUTED FOR THE COMMON NAILS AS SPECIFIED
WITHIN EACH APPENDIX BY APPLYING THE FOLLOWING GUIDANCE. THE NUM-
BER OF COOLER NAILS TO BE USED WILL BE THE NUMBER OF COMMON NAILS
MULTIPLIED BY 1.2 AND ROUNDED UP TO THE NEXT WHOLE NUMBER. THE SIZE
OF THE COOLER NAILS TO BE USED WILL BE THE SAME AS SPECIFIED FOR THE
COMMON NAILS (4d, 6d, 10d, ETC.) BUT WILL CONFORM TO THE SIZE AND
WEIGHT TOLERANCES SPECIFIED WITHIN ASTM F1667 FOR COOLER NAILS.
HH. REFER TO DAC DRAWING ACV00617 FOR APPROVED SOURCES FOR SEALLESS
(CLIPLESS) SEALING TOOL. THESE APPROVED SEALING TOOLS CAN BE USED IN
PLACE OF SEALS CURRENTLY SPECIFIED IN THE "MATERIAL SPECIFICATIONS"
ON PAGE 2.
JJ. ALL NON-MANUFACTURED WOOD USED IN THE UNIT LOAD WILL BE HEAT TREAT-
ED AND MARKED TO SHOW CONFORMANCE TO THE INTERNATIONAL PLANT
PROTECTION CONVENTION STANDARD (IPPC), ISPM-15. SEE DAC DRAWING
ACV00831 FOR ISPM-15 CERTIFICATION MARKING AND PLACEMENT DETAILS.
FILLER BLOCK, 1" X 3" BY CUT-TO- FIT
BETWEEN OPPOSITE END-CLEATS OF BOX.
POSITION UNDER STRAP.
INDICATES A
HORIZONTAL STRAP
INDICATES
WIREBOUND BOX
INDICATES BROKEN
END-CLEAT
STAPLE STRAP TO FILLER
BLOCK W/2 STAPLES.
INDICATES A TIEDOWN OR LOAD
STRAP THAT CANNOT BE INSTALLED
AT THE PREFERRED LOCATION.
INDICATES A PREFERRED
LOCATION FOR ALL UNIT-
IZING STRAPS (NEAR A
CLEAT WHICH IS PARALLEL
TO THE STRAP).
FILLER BLOCK FOR
HORIZONTAL STRAP
SPECIAL REINFORCEMENT FOR WIREBOUND BOXES
SEE GENERAL NOTE “X” ON PAGE 3.
INDICATES BROKEN
END-CLEAT
OTHER STRAP END
ON TOP SIDE
STEEL STRAPPING
STRAP RETENSIONING
TAB. SIX INCH MINIMUM
LENGTH TAB ON END
OF UNDERNEATH STRAP.
STRAP SEAL
UNITIZATION NOTES
○1 POSITION BOXES SO THEY ARE CENTERED LENGTHWISE AND WIDTHWISE ON
THE PALLET DECK. IF BOXES ARE OF THE HINGED-TOP TYPE, THE OUTSIDE
BOXES IN THE TOP LAYER WILL BE POSITIONED SO THAT THE HINGES WILL BE
INWARD. SEE GENERAL NOTE "G" ON PAGE 2.
○2 LOAD STRAP, 3/4" X .035" OR .031" OR .029” BY LENGTH TO SUIT STEEL STRAP-
PING (AS REQD). MAY BE INSTALLED THROUGH THE STRAP SLOT OF A PALLET
OR PRE-POSITIONED ON THE PALLET DECK PRIOR TO PLACING BOXES ON THE
PALLET. SEE GENERAL NOTES "K" AND "L" ON PAGE 2, AND "M" ON PAGE 3.
STRAPS SHALL NOT BE PLACED UNDER THE STRINGER BOARDS.
○3 HORIZONTAL STRAP, 3/4" X .035" OR .031" OR .029” BY LENGTH TO SUIT STEEL
STRAPPING (AS REQD). INSTALL STRAP TO ENCIRCLE A LAYER OF BOXES ON
THE PALLET AS SHOWN. SEE GENERAL NOTES "K" AND "L" ON PAGE 2, AND "M"
ON PAGE 3.
○4 TIEDOWN STRAP, 3/4" X .035" OR .031" OR .029” BY LENGTH TO SUIT STEEL
STRAPPING (AS REQD). INSTALL EACH STRAP TO PASS UNDER THE DECK
BOARDS OR DECK/STRINGER BOARDS OF THE PALLET AS SHOWN. SEE GEN-
ERAL NOTES "K" AND "L" ON PAGE 2, AND "M" ON PAGE 3.
○5 SEAL FOR 3/4" STRAPPING (AS REQD, 1 PER STRAP). CRIMP EACH SEAL WITH
TWO PAIR OF NOTCHES. SEE GENERAL NOTE "K" ON PAGE 2.
STRAP RETENSIONING TAB
SEE GENERAL NOTE “L” ON PAGE 2.
TYPICAL PALLET UNIT
UNIT WIDTH
UNIT LENGTH
35 1/2"
4-WAY ENTRY
PALLET
TYPICAL PALLET UNIT WITH ONE SPACER ASSEMBLY
THIS VIEW DEPICTS THE APPLICATION OF A TYPICAL SPACER ASSEMBLY, POSITIONED LENGTHWISE IN THE UNIT LOAD, TO ENLARGE THE UNIT WIDTH TO SLIGHTLY OVERHANG OR TO MATCH THE WIDTH DIMENSION OF THE PALLET DECK.
SIMILARLY, TO ENLARGE THE UNIT LENGTH, A SPACER ASSEMBLY WOULD BE POSITIONED WIDTHWISE IN THE LOAD. SEE
GENERAL NOTES "D.3" ON PAGE 2 AND "V" ON PAGE 3.
INDICATES CENTER STACKS WITHIN THE
UNIT LENGTH FOR POSITIONING ONE OR
MORE FILLER ASSEMBLIES WHEN REQUIRED. INDICATES A TYPICAL
SPACER ASSEMBLY
INDICATES HORIZONTAL STRAP
INDICATES TIEDOWN STRAP
4-WAY ENTRY PALLET
UNIT HEIGHT
UNIT WIDTH
UNIT LENGTH
TYPICAL PALLET UNIT WITH THREE SPACER ASSEMBLIES
THIS VIEW DEPICTS THE APPLICATION OF THREE TYPICAL SPACER ASSEMBLIES TO ENLARGE BOTH THE WIDTH AND THE LENGTH OF THE UNIT LOAD TO PROVIDE A SLIGHT OVERHANG ON THE PALLET OR TO MATCH THE WIDTH AND/OR LENGTH DIMENSIONS OF THE PALLET DECK. SEE GENERAL NOTES "D.3" ON PAGE 2 AND "V" ON PAGE 3.
INDICATES TYPICAL
SPACER ASSEMBLIES
C S C S CO OS O GO O O SS SQC S C S CG O OS O GO O O SS SQ
INDICATES TIEDOWN STRAP
INDICATES HORIZONTAL STRAP
4-WAY ENTRY PALLET
UNIT HEIGHT
UNIT WIDTH
UNIT LENGTH
PROVISIONS FOR LESS-THAN-FULL-LAYER LOADS
1. THE FOLLOWING PROVISIONS SET FORTH THE SPECIFICATIONS THAT MUST BE
FOLLOWED IF A FILLER TYPE ASSEMBLY IS USED TO ACHIEVE A FULL-LAYER
PALLET UNIT.
A. FILLERS ARE DESIGNED FOR USE IN THE PLACE OF ONE OR MORE BOXES
OF A UNIT. FILLER ASSEMBLY DETAILS WILL BE DEPICTED IN THE APPENDIX
APPLICABLE TO THE SPECIFIC ITEM TO BE UNITIZED. SEE GENERAL NOTE
"W" ON PAGE 3 AND THE TYPICAL FILLER ASSEMBLY DETAILS ON PAGE 9.
B. FILLERS WILL BE POSITIONED IN THE TOP LAYER OR LAYERS OF THE CEN-
TER STACK OR STACKS WITHIN THE UNIT LENGTH OF A UNIT LOAD AS
SHOWN IN THE TWO "TYPICAL APPLICATIONS OF FILLER" VIEWS ABOVE AND
REFERENCED IN PALLET UNIT DETAILS ON PAGE 6. FILLERS CAN ALSO BE
POSITIONED IN THE TOP LAYER OR LAYERS OF THE CENTER STACK OR
STACKS WITHIN THE UNIT WIDTH OF A UNIT LOAD WHEN THE QUANTITY OF
FILLERS POSITIONED WITHIN THE UNIT LENGTH IS INSUFFICIENT TO SATIS-
FY THE OMITTED-BOX QUANTITY REQUIREMENTS.
2. EMPTY BOXES, PREFERABLY "REJECTS", CAN BE USED AS FILLERS INSTEAD OF
WOODEN DUNNAGE ASSEMBLIES INDICATED ABOVE, TO ACHIEVE A FULL-
LAYER PALLET UNIT. HOWEVER, EMPTY BOXES WILL BE USED ONLY IN THE
TOP LAYER OF A PALLET UNIT AND POSITIONED AT ANY OF THE FOUR COR-
NERS OF THE LAYER (NOT IN THE MIDDLE OF THE LAYER). NOT MORE THAN
FOUR EMPTY BOXES MAY BE USED IN A UNIT LOAD. WHEN EMPTY BOXES ARE
USED TO FILL OUT A LAYER, THE EMPTY BOXES WILL BE PAINTED AND MARKED
AS SPECIFIED IN DAC DRAWING ACV00561 AND ARDEC DRAWING 12982865.
FOR HYDRA-70 CONFIGURATION ONLY, PAINT AND MARK AS SPECIFIED IN
AMCOM DRAWING 13643712. SEE NOTE 6 BELOW.
3. IF EMPTY WOODEN BOXES ARE USED AS FILLERS, WOOD REINFORCING
BLOCKS OF 2" THICK MATERIAL BY LENGTHS REQUIRED, MAY BE POSITIONED
INSIDE THE BOXES TO PREVENT THEM FROM CRUSHING OR COLLAPSING
WHEN UNITIZING STRAPS ARE TENSIONED. TO HOLD THE BLOCKS IN PLACE,
DRIVE 6d NAILS THROUGH THE BOX AND INTO THE ENDS OF THE REINFORCING
BLOCKS. SEE THE "TYPICAL INSTALLATION OF REINFORCING BLOCKS IN AN
EMPTY BOX" DETAIL ON THIS PAGE.
4. IF EMPTY WIREBOUND BOXES ARE TO BE USED AS FILLERS, ONLY THOSE HAV-
ING EMPTY RECTANGULAR METAL CONTAINERS AS INNER PACKS CAN BE
USED. FILLER ASSEMBLIES MUST BE USED IN PLACE OF WIREBOUND BOXES
TO SATISFY LESS-THAN-FULL-LAYER LOAD REQUIREMENTS WHEN THE INNER
PACKS OF THE WIREBOUND BOXES DO NOT CONSIST OF RECTANGULAR MET-
AL CONTAINERS.
5. LESS THAN FULL BOXES OF AMMUNITION (LIGHT BOXES) WILL BE PAINTED AND
MARKED AS SPECIFIED IN ARDEC DRAWINGS 8796522 OR 12982865. LIGHT
BOXES WILL ONLY BE PLACED IN THE TOP LAYER OF A UNIT AND LOCATED AT
ANY OF THE FOUR CORNERS OF THE LAYER (NOT IN THE MIDDLE OF THE LAY-
ER). NOT MORE THAN TWO LIGHT BOXES (ONE PER LOT) WILL BE PLACED IN A
UNIT LOAD. FOR HYDRA-70 CONFIGURATION ONLY, PAINT AND MARK AS SPEC-
IFIED IN DRAWING 13643712. SEE NOTE 6 BELOW.
6. TO SATISFY THE REQUIREMENTS FOR A FULL-LAYER UNIT, IT IS PERMISSIBLE
TO USE A COMBINATION OF EMPTY AND LIGHT BOXES IN THE TOP LAYER.
HOWEVER, IF A TOTAL OF FOUR EMPTY AND LIGHT BOXES DOES NOT PROVIDE
FOR A FULL LAYER, ONE OR MORE FILLER ASSEMBLIES MUST BE USED IN THE
MIDDLE OF THE LAYER TO INSURE COMPLIANCE WITH THE LIMITATIONS SPECI-
FIED IN NOTES 2 AND/OR 5 ABOVE.
7. EACH PALLET UNIT LOAD CONTAINING EMPTY AND/OR LIGHT BOXES WILL HAVE
A WEATHER RESISTANT PLACARD OR TAG PREPARED AND APPLIED TO THE
UNIT LOAD AS STATED IN DAC DRAWING ACV00561.
(CONTINUED ON PAGE 8)
LESS-THAN-FULL-LAYER UNIT LOADS
TYPICAL INSTALLATION OF REINFORCING
BLOCKS IN AN EMPTY BOX
(UNITIZING STRAPS HAVE BEEN OMITTED FROM THE DETAIL
ABOVE FOR CLARITY PURPOSES).
USE OF EMPTY/LIGHT BOXES TO ACHIEVE A
FULL LAYER
(UNITIZING STRAPS HAVE BEEN OMITTED FROM THE DETAIL
ABOVE FOR CLARITY PURPOSES).
TYPICAL APPLICATION OF FILLER
(ONE BOX OMITTED)
TYPICAL APPLICATION OF FILLER
(THREE BOXES OMITTED)
TYPICAL FILLER ASSEMBLY
OR ASSEMBLIES FOR THREE
OMITTED BOXES.
TYPICAL FILLER ASSEMBLY
FOR ONE OMITTED BOX.
INDICATES CENTER
STACKS OF UNIT
WIDTH
INDICATES CENTER
STACK OF UNIT
LENGTH
EMPTY/LIGHT
BOXES
TYPICAL LOCATION OF
WEATHER RESISTANT
PLACARD.
VERTICAL
REINFORCING
BLOCK
HORIZONTAL
REINFORCING
BLOCK
(PROVISIONS FOR LESS-THAN-FULL-LAYER LOADS CONTINUED FROM PAGE 7)
8. EXCEPTION TO THE RULE: THIS EXCEPTION ADDRESSES THE USE OF A FILLER ASSEMBLY OR FILLER ASSEMBLIES
WITHIN A UNIT LOAD TO CONSTRUCT A COMPLETE-LAYER UNIT LOAD. THE SPECIFICATIONS DELINEATED WITHIN THIS DRAWING ARE BASED ON UNIT LOADS THAT CONTAIN SEVERAL AMMUNITION PACKS WHICH ARE ARRANGED IN MULTIPLE LAYERS AND MULTIPLE STACKS ON A PALLET BASE. FOR THESE TYPES OF UNIT LOADS A FILLER OR FILLERS ARE TO BE PLACED AS SPECIFIED ELSEWHERE HEREIN, IN THE TOP LAYER OR LAYERS OF MIDDLE STACKS (NOT IN A CORNER STACK). THERE ARE, HOWEVER, MANY PALLET UNITS THAT ONLY CONTAIN ONE LAYER OF AMMUNITION PACKS, OR PALLET UNITS WHERE THE PACKS ARE ARRANGED IN ONLY TWO OR FOUR STACKS ON A PALLET BASE. THE USE OF A FILLER OR FILLERS IN THESE TYPES OF PALLET UNITS IS PERMITTED;
HOWEVER, THE METHODS FOR FILLER APPLICATION WILL HAVE TO DEVIATE FROM THE BASIC RULES SPECIFIED ELSEWHERE WITHIN THIS DRAWING. THIS IS ALSO THE CASE WHEN ONLY ONE PALLET UNIT OF A SPECIFIC COM- MODITY IS BEING PREPARED AND THE PALLET UNIT BEING CONSTRUCTED WILL ONLY HAVE THREE OR FEWER PACKS, WHERE NORMALLY SEVERAL PACKS ARE REQUIRED TO FILL OUT A LAYER. BASICALLY, THE PERMITTED DEVIATION FROM THE BASIC RULES GOVERNING PLACEMENT OF FILLER OR FILLERS IN A UNIT LOAD CONSISTS OF PLACING A FILLER OR FILLERS IN ONE OR MORE OF THE CORNER STACKS OF A PALLET UNIT. IF AN EMPTY "ORANGE" PACK OR PACKS ARE AVAILABLE TO FILL OUT A LAYER ON A PALLET UNIT, THE EMPTY PACK OR PACKS SHOULD BE USED IN A CORNER STACK LOCATION INSTEAD OF A FILLER ASSEMBLY. ANOTHER DEVIATION FROM THE BASIC RULES AS THEY APPLY TO USE OF FILLER ASSEMBLIES IS ALSO PERMITTED. THIS DEVIATION IS ASSO- CIATED WITH SINGLE-LAYER UNIT LOADS, AND PERMITS THE USE OF FILLER ASSEMBLIES WITH TWO UNIT LOADS RATHER THAN WITHIN JUST ONE, TO ACHIEVE SOUND AND EFFECTIVE UNIT LOADS. SPECIFIC GUIDANCE RELA- TIVE TO THE USE OF THIS LATTER DEVIATION IS SET FORTH IN APPLICABLE INDIVIDUAL APPENDICES THAT AUG-
MENT THIS BASIC PROCEDURES DRAWING.
ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS
UNIT LENGTH VIEW UNIT WIDTH VIEW
UNIT TOP VIEW
SPECIAL NOTES:
1. DIMENSIONS APPLICABLE TO ALLOWABLE TOLERANCES ARE EXPRESSED IN
INCHES AND IDENTIFIED BY LETTERS AS FOLLOWS.
A = UNIT LENGTH
B = PALLET LENGTH
C = UNIT WIDTH
D = PALLET WIDTH
E = LENGTHWISE OVERHANG = (A-B) / 2 WITH A PLUS OR MINUS 1/2" TOLER-
ANCE FOR EACH LAYER AND FOR EACH STACK
F = ALLOWABLE UNIT LENGTH = "A" PLUS 1/2" MAXIMUM
G = WIDTHWISE OVERHANG = (C-D) / 2 WITH A PLUS OR MINUS 1/2" TOLER-
ANCE FOR EACH LAYER AND FOR EACH STACK
H = ALLOWABLE UNIT WIDTH = "C" PLUS 1/2" MAXIMUM
J = UNIT HEIGHT
K = VERTICAL STRAP ALIGNMENT = J / 40 = MAXIMUM INCHES FROM TRUE
ALIGNMENT (E.G., IF J = 50", K = 50” / 40" = 1-1/4" MAX)
L = TRANSVERSE STRAP ALIGNMENT = C / 40 = MAXIMUM INCHES FROM TRUE
ALIGNMENT (E.G., IF C = 55", L = 55” / 40" = 1-3/8" MAX)
2. BOX ALIGNMENT TOLERANCES APPLY TO EACH LAYER AND TO EACH STACK
RELATIVE TO THE PALLET DECK. SEE GENERAL NOTE "F" ON PAGE 2 AND "U"
ON PAGE 3.
3. STRAPPING TOLERANCES APPLY TO ALL STRAPS AND TO ALL SURFACES
WHICH EACH STRAP ENCOMPASSES, I. E., TOP, BOTTOM, AND BOTH SIDES.
F
A
B E
INDICATES
STRAP
J
H
C
J
DG
C
F
D
GEINDICATES PALLET
(PHANTOM)
L
INDICATES BOX
INDICATES STRAP
K
SPECIAL NOTES:
1. TYPICAL FILLER ASSEMBLIES “A” AND “B” ARE TYPICAL OF THE ASSEMBLIES
USED TO REPLACE CLEATED WOODEN BOXES, AND TYPICAL FILLER ASSEM-
BLIES “C” AND “D” ARE TYPICAL OF THE ASSEMBLIES USED TO REPLACE
WIREBOUND BOXES. THE DECISION OF WHICH FILLER ASSEMBLY TO USE
WILL BE BASED UPON MATERIAL AVAILABILITY AND CONSTRUCTION ECONOM-
ICS.
2. FILLER ASSEMBLIES MUST BE ASSEMBLED WITHIN ALLOWABLE TOLERANCES.
SEE GENERAL NOTE "H" ON PAGE 2.
3. SEE THE APPLICABLE APPENDIX TO DETERMINE THE RECOMMENDED FILLER
ASSEMBLY FOR A PARTICULAR ITEM. SEE GENERAL NOTE "W" ON PAGE 3.
TYPICAL FILLER ASSEMBLY D
SEE SPECIAL NOTES BELOW.
TYPICAL FILLER ASSEMBLY C
TYPICAL FILLER ASSEMBLY A
TYPICAL FILLER ASSEMBLY B
INDICATES 1" X 4"
DUNNAGE LUMBER
INDICATES 2"
DUNNAGE LUMBER
INDICATES APPROPRIATELY
SIZED NAILS (AS REQD)
BOX LENGTH
BOX HEIGHT
BOX WIDTH
1"
BOX LENGTH
INDICATES 1" X 4"
DUNNAGE LUMBER
BOX WIDTH
INDICATES 2"
DUNNAGE LUMBER
INDICATES APPROPRIATELY
SIZED NAILS (AS REQD)
1"
BOX HEIGHT
BOX LENGTH BOX WIDTH
INDICATES 1" X 4"
DUNNAGE LUMBER
INDICATES 2"
DUNNAGE LUMBER INDICATES APPROPRIATELY
SIZED NAILS (AS REQD)
BOX WIDTHBOX LENGTH
BOX HEIGHT
INDICATES APPROPRIATELY
SIZED NAILS (AS REQD) INDICATES 2"
DUNNAGE LUMBER
REVISIONS
REVISION NO. 1, DATED OCTOBER 1983, CONSISTS OF:
1. ADDING NOTES TO COVER UNITIZATION OF WIREBOUND BOXES.
2. UPDATING NOTES AND PROCEDURES TO CONFORM TO CURRENT STANDARD.
REVISION NO. 2, DATED JUNE 1985, CONSISTS OF:
CHANGING GENERAL NOTE “AA” TO CONFORM TO CURRENT STANDARDS.
REVISION NO. 3, DATED DECEMBER 1986, CONSISTS OF:
ADDING PAGE 8 (FILLER ASSEMBLIES).
REVISION NO. 4, DATED FEBRUARY 1989, CONSISTS OF:
UPDATING GENERAL NOTES.
REVISION NO. 5, DATED MARCH 1996, CONSISTS OF:
UPDATING GENERAL NOTES.
REVISION NO. 6, DATED JUNE 2000, CONSISTS OF:
1. UPDATING MATERIAL SPECIFICATIONS AND RELATED GENERAL NOTES.
2. ADDING DAC WEB SITE INFORMATION.
3. ADDING THE CLIPLESS SEAL NOTE.
REVISION NO. 7, DATED SEPTEMBER 2001, CONSISTS OF:
UPDATING GENERAL NOTE “E” AND ADDING GENERAL NOTE “JJ”.
REVISION NO. 8, DATED JUNE 2003, CONSISTS OF CHANGES PER ECPS R2K3000 AND R2K3010 INCLUD-
ING:
1. UPDATING STRAPPING, WOOD AND STAPLE SPECIFICATIONS.
2. UPDATING GENERAL NOTE “JJ”.
REVISION NO. 9, DATED AUGUST 2005, CONSISTS OF:
1. UPDATING GENERAL NOTES.
2. REMOVING STRAP CUTTER NOTE (GENERAL NOTE “P”) AND REFERENCES AND REPLACING IT WITH
ROOFING NAIL NOTE.
REVISION NO. 10, DATED AUGUST 2006, CONSISTS OF:
1. UPDATING GENERAL NOTE “JJ”.
2. ADDING PLYWOOD MATERIAL SPECIFICATION.
REVISION NO. 11, DATED JULY 2008, CONSISTS OF CHANGES PER ECPS R07K3013 (1-2), R08K2045 (3), AND R08K3007 (4) INCLUDING:
1. UPDATING STEEL STRAPPING SPECIFICATION TO INCLUDE .029” THICKNESS STRAPPING.
2. DELETING REFERENCE TO TANALITH E OR TANALITH E3492 FROM GENERAL NOTE “AA”.
3. DELETING CONFIGURATION MANAGEMENT STATEMENT.
4. UPDATING STAPLE SPECIFICATION TO ALLOW STFCS-198 OR -216 STAPLE.
REVISION NO. 12, DATED DECEMBER 2011, CONSISTS OF CHANGES PER ECP R11K3001 INCLUDING:
1. UPDATING DRAWING FORMAT.
2. UPDATING OFFICE SYMBOL ON COVER PAGE AND IN GENERAL NOTE “E”.
3. CORRECTING MISSPELLING IN GENERAL NOTE “P”.
4. UPDATING GENERAL NOTE “S” TO REMOVE REFERENCE TO DRAWING INDEX, AMC 19-48-75-5.
5. CHANGING MIL-B-2427 TO MIL-DTL-2427 IN GENERAL NOTE “AA”.
6. REWORDING GENERAL NOTE “JJ” WITH NEW REFERENCE TO DAC DRAWING ACV00831.
7. UPDATING STRAP THICKNESS IN UNITIZATION NOTES 2, 3, AND 4 ON PAGE 5.
REVISION NO. 13, DATED JANUARY 2017, CONSISTS OF CHANGES PER ECP MI-R0891 (2) INCLUDING:
1. UPDATING DRAWING FORMAT.
2. CHANGING MIL-P-15011 TO MIL-DTL-15011 IN THE PALLET MATERIAL SPECIFICATIONS.
3. DELETING REFERENCE TO GENERAL NOTE “JJ” (HEAT TREATMENT) FROM PALLET SPECIFICATION.
4. UPDATING GENERAL NOTE “AA” (PRESERVATIVE TREATMENT) TO INCORPORATE NEW ARDEC
DRAWING.
REVISION NO. 14, DATED DECEMBER 2019, CONSISTS OF CHANGES PER ECP MI-P1690R2A1 NOR 79 IN-
CLUDING:
UPDATING NOTES 2 AND 5 ON PAGE 7 TO INCLUDE PAINT AND MARK INFORMATION FOR HYDRA-70.
File details come from the government source that posted it. Updated .