Attachment 0002 - Tables (1-3).xlsx

XLSX spreadsheet 14 KB Posted

Attached to
M68 Optic Close Combat Sight Reflex
Solicitation number
W912CH24R0086
Issued by

About this file

This file contains three quality assurance and inspection tables for the M68 Optic Close Combat Sight Reflex (NSN 1240-01-576-6134), establishing the testing and conformance requirements for this military optical device.

Table I specifies attributes sampling inspection procedures based on lot size, ranging from 2-8 units requiring 100% inspection to 281-500 units requiring a sample size of 32 with acceptance on zero defects and rejection on one or more. Table II details the First Article Test requirements, mandating 100% conformance testing across 34 examination categories including magnification, clear aperture, dot angular spot size, parallax, illuminance, adjustment repeatability, power source, hue, height above bore, external coatings, sealing, radioactive material content, optical quality, lens/dust cover, operability, shock, vibration, temperature, humidity, NBC decontamination, corrosion resistance, fungus, chemical resistance, sand and dust, thermal shock, live fire, drop requirements, weight, marking, laser spectacles compatibility, and image intensifier compatibility. Test responsibilities are divided between the contractor and government, with government conducting critical environmental and ballistic tests including live fire and drop testing. Table III establishes Quality Conformance Inspection requirements with 16 major defect categories (numbered 101-116) tested at Level 1 or per Note 2 specifications, and 2 minor defect categories (numbered 201-202), all employing Level I or Level II sampling inspection. The major defects address optical performance, adjustment quality, sealing, environmental durability, and radioactive material compliance, while minor defects focus on materials verification and weight specifications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table I

TABLE I- ATTRIBUTES SAMPLING INSPECTION-AR PD 115
SIGHT, REFLEX WITH MOUNT, M68
INSPECTION LEVELS
LOT SIZEIII
2 to 8*5
9 to 15*5
16 to 25*5
26 to 50325
51 to 90323
91 to 1503213
151 to 2803220
281 to 5003220
Numbers under inspection levels indicatate sample size; astricks(*) indicate one
hundred percent inspection. If sample size exceeds lot size, perform one hundred
percent inspection. Accept on zero and reject on one or more for all inspection levels

Table II

TABLE II- FIRST ARTICLE TEST-AR PD 115
SIGHT, REFLEX WITH MOUNT, M68
CLASSIFICATION EXAMINATION OR TESTCONFORMANCE REQUIREMENT CRITERIAPARAGRAPHRESPONSIBILITY
Contractor(1)
Magnification100%C.6.1Contractor(1)
Clear apeture100%C.6.1.2Contractor(1)
Dot angular spot size100%C.6.1.4Contractor(1)
parallax100%C.6.1.5Contractor(1)
Illuminance100%C.6.2Contractor(1)
Azimuth and elevation adjustment100%C.6.3Contractor(1)
Adjustment repeatability100%C.6.4Contractor(1)
Power Source100%C.5.1/C.6.5.6/C.6.5Contractor(1)
Hue100%C.6.6Contractor(1)
Signature100%C.6.7Contractor(1)
height Above Bore100%C.6.8Government
External Coatings100%C.7.1Contractor(1) (COC)
Sealing100%C.7.1.1Contractor(1)
Radioactive material content100%C.7.2Contractor(1)
Cleanliness and optical quality100%C.7.3Contractor(1)
Materials and construction100%C.7.4Contractor(1)(COC)
Lens/Dust Cover100%C.7.5Contractor(1)
Operability100%C.8.1Government
Attachment100%C.9.1Contractor(1)
Reattachment line of sight retention100%C.9.1.2Contractor(1)
Shock100%C.10.1.1Contractor(1)
Vibration100%C.10.1.2Contractor(1)
Temperature100%C.10.1.3Contractor(1)
Humidity100%C.10.1.4Contractor(1)
NBC Decontamination100%C.10.1.5Government (Field procedure)
Corrosion Resistance100%C.10.1.6Government (MIL-STD-810)
Fungus100%C.10.1.7Contractor
Chemical resistance100%C.10.1.8Contractor
Sand and dust100%C.10.1.9Government (MIL-STD-810)
Thermal Shock100%C.10.1.10Contractor(1)
Live Fire100%C.11.1Government
Drop Requirement100%C.11.1Government
Weight100%C.9.1.5Contractor
Radioactive material content100%C.7.2Contractor(1)
Contamination Limits100%C.10.1.5Contractor(1)
Marking100%C.7.6Contractor(1)
Laser Spectacles Compatibility100%C.12.1Government
Image Intensifier Compatibility100%C.6.2/C.6.6/C.6.7Government

Table III

TABLE III- QUALITY CONFORMANCE INSPECTION- AR PD 115
SIGHT, REFLEX WITH MOUNT, ,68
CLASSIFICATIONEXAMINATION OR TESTCONFORMANCE REQUIREMENT CRITERIAPARAGRAPHRESPONSIBILITY
MAJOR
101Dot angular spot sizeLevel 1C.6.1.4Contractor(1)
102ParallaxLevel 1C.6.1.5Contractor(1)
103IlluminationLevel 1C.6.2Contractor(1)
104Azimuth & elevation adjustmentLevel 1C.6.3Contractor(1)
105Adjustment repeatabilityLevel 1C.6.4Contractor(1)
106HueLevel 1C.6.6Contractor(1)
107Cleanliness & optical qualityLevel 1C.7.3Contractor(1)- Visual
108Reattachment line of sight retentionLevel 1C.9.1.2Contractor(1)
109Radioactive material contentLevel 1C.7.2Government (COC)
110Power sourceNote 2C.5.1/C.6.5.6/C.6.5Contractor(1)
111SealingNote 2C.7.1.1Contractor(1)
112ShockNote 2C.10.1.1Contractor(1)
113VibrationNote 2C.10.1.2Contractor(1)
114TemperatureNote 2C.10.1.3Contractor(1)
115HumidityNote 2C.10.1.3Contractor(1)
116Corrosion resistanceNote 2C.10.1.6Contractor(1)
MINOR
201Materials and constructionLevel IIC.7.4Contractor(1)-Visual
202WeightLevel IIC.9.1.5Contractor(1)

File details come from the government source that posted it. Updated .