Attachment 0002 - Tables (1-3).xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- M68 Optic Close Combat Sight Reflex
- Solicitation number
- W912CH24R0086
- Issued by
-
Department of the Army
About this file
This file contains three quality assurance and inspection tables for the M68 Optic Close Combat Sight Reflex (NSN 1240-01-576-6134), establishing the testing and conformance requirements for this military optical device.
Table I specifies attributes sampling inspection procedures based on lot size, ranging from 2-8 units requiring 100% inspection to 281-500 units requiring a sample size of 32 with acceptance on zero defects and rejection on one or more. Table II details the First Article Test requirements, mandating 100% conformance testing across 34 examination categories including magnification, clear aperture, dot angular spot size, parallax, illuminance, adjustment repeatability, power source, hue, height above bore, external coatings, sealing, radioactive material content, optical quality, lens/dust cover, operability, shock, vibration, temperature, humidity, NBC decontamination, corrosion resistance, fungus, chemical resistance, sand and dust, thermal shock, live fire, drop requirements, weight, marking, laser spectacles compatibility, and image intensifier compatibility. Test responsibilities are divided between the contractor and government, with government conducting critical environmental and ballistic tests including live fire and drop testing. Table III establishes Quality Conformance Inspection requirements with 16 major defect categories (numbered 101-116) tested at Level 1 or per Note 2 specifications, and 2 minor defect categories (numbered 201-202), all employing Level I or Level II sampling inspection. The major defects address optical performance, adjustment quality, sealing, environmental durability, and radioactive material compliance, while minor defects focus on materials verification and weight specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912CH24R0086-0001.pdf | ||
| Attachment 0008 - TACOM Opsec Plan.pdf | ||
| Attachment 0005 - Past Performance Questionnaire.docx | DOCX document | |
| Attachment 0004 - Pricing Worksheet.xlsx | XLSX spreadsheet | |
| Attachment 0006 - Past Performance Matrix.xlsx | XLSX spreadsheet | |
| Attachment 0001 - CUI 2024.pdf | ||
| Attachment 0007 - Use of Existing Government-Furnished Property.xlsx | XLSX spreadsheet | |
| Attachment 0003 - First Article Test Waiver Worksheet.pdf | ||
| Exhibit A - Contract Data Requirements List (CDRL) A001 - A006.pdf | ||
| W912CH24R0086.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table I
| TABLE I- ATTRIBUTES SAMPLING INSPECTION-AR PD 115 | |||||
| SIGHT, REFLEX WITH MOUNT, M68 | |||||
| INSPECTION LEVELS | |||||
| LOT SIZE | I | II | |||
| 2 to 8 | * | 5 | |||
| 9 to 15 | * | 5 | |||
| 16 to 25 | * | 5 | |||
| 26 to 50 | 32 | 5 | |||
| 51 to 90 | 32 | 3 | |||
| 91 to 150 | 32 | 13 | |||
| 151 to 280 | 32 | 20 | |||
| 281 to 500 | 32 | 20 | |||
| Numbers under inspection levels indicatate sample size; astricks(*) indicate one | |||||
| hundred percent inspection. If sample size exceeds lot size, perform one hundred | |||||
| percent inspection. Accept on zero and reject on one or more for all inspection levels |
Table II
| TABLE II- FIRST ARTICLE TEST-AR PD 115 | ||||
| SIGHT, REFLEX WITH MOUNT, M68 | ||||
| CLASSIFICATION EXAMINATION OR TEST | CONFORMANCE REQUIREMENT CRITERIA | PARAGRAPH | RESPONSIBILITY | |
| Contractor(1) | ||||
| Magnification | 100% | C.6.1 | Contractor(1) | |
| Clear apeture | 100% | C.6.1.2 | Contractor(1) | |
| Dot angular spot size | 100% | C.6.1.4 | Contractor(1) | |
| parallax | 100% | C.6.1.5 | Contractor(1) | |
| Illuminance | 100% | C.6.2 | Contractor(1) | |
| Azimuth and elevation adjustment | 100% | C.6.3 | Contractor(1) | |
| Adjustment repeatability | 100% | C.6.4 | Contractor(1) | |
| Power Source | 100% | C.5.1/C.6.5.6/C.6.5 | Contractor(1) | |
| Hue | 100% | C.6.6 | Contractor(1) | |
| Signature | 100% | C.6.7 | Contractor(1) | |
| height Above Bore | 100% | C.6.8 | Government | |
| External Coatings | 100% | C.7.1 | Contractor(1) (COC) | |
| Sealing | 100% | C.7.1.1 | Contractor(1) | |
| Radioactive material content | 100% | C.7.2 | Contractor(1) | |
| Cleanliness and optical quality | 100% | C.7.3 | Contractor(1) | |
| Materials and construction | 100% | C.7.4 | Contractor(1)(COC) | |
| Lens/Dust Cover | 100% | C.7.5 | Contractor(1) | |
| Operability | 100% | C.8.1 | Government | |
| Attachment | 100% | C.9.1 | Contractor(1) | |
| Reattachment line of sight retention | 100% | C.9.1.2 | Contractor(1) | |
| Shock | 100% | C.10.1.1 | Contractor(1) | |
| Vibration | 100% | C.10.1.2 | Contractor(1) | |
| Temperature | 100% | C.10.1.3 | Contractor(1) | |
| Humidity | 100% | C.10.1.4 | Contractor(1) | |
| NBC Decontamination | 100% | C.10.1.5 | Government (Field procedure) | |
| Corrosion Resistance | 100% | C.10.1.6 | Government (MIL-STD-810) | |
| Fungus | 100% | C.10.1.7 | Contractor | |
| Chemical resistance | 100% | C.10.1.8 | Contractor | |
| Sand and dust | 100% | C.10.1.9 | Government (MIL-STD-810) | |
| Thermal Shock | 100% | C.10.1.10 | Contractor(1) | |
| Live Fire | 100% | C.11.1 | Government | |
| Drop Requirement | 100% | C.11.1 | Government | |
| Weight | 100% | C.9.1.5 | Contractor | |
| Radioactive material content | 100% | C.7.2 | Contractor(1) | |
| Contamination Limits | 100% | C.10.1.5 | Contractor(1) | |
| Marking | 100% | C.7.6 | Contractor(1) | |
| Laser Spectacles Compatibility | 100% | C.12.1 | Government | |
| Image Intensifier Compatibility | 100% | C.6.2/C.6.6/C.6.7 | Government |
Table III
| TABLE III- QUALITY CONFORMANCE INSPECTION- AR PD 115 | ||||
| SIGHT, REFLEX WITH MOUNT, ,68 | ||||
| CLASSIFICATION | EXAMINATION OR TEST | CONFORMANCE REQUIREMENT CRITERIA | PARAGRAPH | RESPONSIBILITY |
| MAJOR | ||||
| 101 | Dot angular spot size | Level 1 | C.6.1.4 | Contractor(1) |
| 102 | Parallax | Level 1 | C.6.1.5 | Contractor(1) |
| 103 | Illumination | Level 1 | C.6.2 | Contractor(1) |
| 104 | Azimuth & elevation adjustment | Level 1 | C.6.3 | Contractor(1) |
| 105 | Adjustment repeatability | Level 1 | C.6.4 | Contractor(1) |
| 106 | Hue | Level 1 | C.6.6 | Contractor(1) |
| 107 | Cleanliness & optical quality | Level 1 | C.7.3 | Contractor(1)- Visual |
| 108 | Reattachment line of sight retention | Level 1 | C.9.1.2 | Contractor(1) |
| 109 | Radioactive material content | Level 1 | C.7.2 | Government (COC) |
| 110 | Power source | Note 2 | C.5.1/C.6.5.6/C.6.5 | Contractor(1) |
| 111 | Sealing | Note 2 | C.7.1.1 | Contractor(1) |
| 112 | Shock | Note 2 | C.10.1.1 | Contractor(1) |
| 113 | Vibration | Note 2 | C.10.1.2 | Contractor(1) |
| 114 | Temperature | Note 2 | C.10.1.3 | Contractor(1) |
| 115 | Humidity | Note 2 | C.10.1.3 | Contractor(1) |
| 116 | Corrosion resistance | Note 2 | C.10.1.6 | Contractor(1) |
| MINOR | ||||
| 201 | Materials and construction | Level II | C.7.4 | Contractor(1)-Visual |
| 202 | Weight | Level II | C.9.1.5 | Contractor(1) |
File details come from the government source that posted it. Updated .