Attachment 0001 - Bldg 148 FATA AS-BUILT SET_2024 31 dtd May 2024.pdf

PDF 14 MB Posted

Attached to
RFQ: Purchase and Installation of Exhaust System for Bldg. 148 Dining Facility at Fort Allen
Solicitation number
W912LR26QA041
Issued by

About this file

This document is an as-built drawing set for repairs to Building #148 Dining Facility at Fort Allen in Juana Diaz, Puerto Rico, prepared by the Puerto Rico Army National Guard and dated May 31, 2024.

The project encompasses comprehensive renovation of an existing dining facility with addition of a new annex. Scope includes demolition of selected interior and exterior elements, construction of a new annex with foundation and structural roof systems, and complete mechanical, electrical, plumbing, and fire protection systems. The architectural design provides multiple functional spaces including dining areas for officers and enlisted personnel, food preparation and storage areas with walk-in coolers and freezer units, scullery, hand wash areas, mechanical rooms, restrooms, storage, and support spaces. The structural work involves concrete foundation systems with reinforced concrete block walls, metal roof construction with appropriate drainage and vent systems, and new window and door installations with schedules. The mechanical systems include a direct expansion air handling unit serving variable air volume boxes for zone control, exhaust and supply fans with ductwork, and condensing units for refrigeration. Electrical work incorporates a new 400-ampere panelboard connected to existing service, branch circuits for equipment, lighting systems throughout, and fire alarm detection with manual pull stations and audible/visual alarm devices. Plumbing includes floor drains, fixture connections, roof vent pipes, and clean-out access points. The drawing set consists of 40 sheets organized by discipline with detailed plans, sections, elevations, schedules, and specifications for construction and installation.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PUERTO RICO ARMY NATIONAL GUARD

REPAIRS TO BUILDING #148 DINING FACILITY

FORT ALLEN JUANA DIAZ P.R

AS BUILT SET

COVER SHEET

DRAWING INDEX

SERIES

P

DRAWING NUMBER

P-1

DRAWING NUMBER

EP ELECTRICAL

DRAWING NUMBER

EP001

EP101

EP102

EP501

01 40

GI001

DESCRIPTION

SCHEDULE AND LEGENDS

ELECTRICAL FLOOR PLAN

ELECTRICAL ROOF PLAN

ELECTRICAL DETAILS

DESCRIPTION

DESCRIPTION

PROPOSED PLUMBING FLOOR PLAN

TI

TL

E

SH

EE

T

D

R

AW

IN

G

IN

D

EX

AS-BUILT SET

DATED: 31 May 2024

SERIES

GI

DRAWING NUMBER

GI001

CIVIL

DRAWING NUMBER

C

C-1

C-2A

C-3

A ARCHITECTURAL

DRAWING NUMBER

A-1

A-2

A-3

A-4

SB STRUCTURAL

DRAWING NUMBER

SB101

SB102

DESCRIPTION

ROOF OPENINGS PLANS

STRUCTURAL DETAILS

DESCRIPTION

DEMOLITION PLAN

DEMOLITION ELEVATIONS

PROPOSED FLOOR PLAN

REFLECTED CEILING PLAN

DESCRIPTION

PROPOSAL SITE PLAN

SERVICE AREA ENLARGED & DETAILS

SITE DETAILS

DESCRIPTION

TITLE SHEET & DRAWING INDEX

A-5 NEW ANNEX ROOF PLAN & DETAILS

A-6 PROPOSED EQUIPMENT LAYOUT

A-7 PROPOSED ELEVATIONS

A-8 PROPOSED SECTIONS

A-9 ENLARGED DETAILS

A-10 WINDOW & DOOR SCHEDULE

S-1 NEW ANNEX FOUNDATION & STRUCTURAL ROOF PLAN

S-2 FOUNDATION & ROOF STRUCTURAL DETAILS

S-3 STRUCTURAL NOTES & TYPICAL DETAILS

SD-1 SERVICE AREA METAL SHEET, ELEVATION & DETAIL

P-1 PROPOSED PLUMBING FLOOR PLAN

PLUMBING

MECHANICALMH

MH001

MH101

MH101-1

MH101-2

MH102

MH401

MH501

MH601

MH602

MH603

HVAC GENERAL SIMBOLS, NOTES AND ABBREVIATIONS

FIRST FLOOR PLAN HVAC LAYOUT

HVAC SUPPLY AIR DISTRIBUTION

HVAC RETURN AND EXHAUST AIR DISTRIBUTION

ROOF PLAN HVAC LAYOUT

HVAC DUCTWORK SECTION

HVAC DETAILS

HVAC SCHEDULES

HVAC CONTROLS

HVAC CONTROLS

E-3 LEGEND, SCHEDULE & NOTES

E-2 POWER FLOOR PLAN

E-1 LUMINARIES FLOOR PLAN

DRAWING NUMBER DESCRIPTION

FIRE PROTECTIONF

F-1 FIRE ALARM FLOOR PLAN

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

AutoCAD SHX Text

AS SHOWN

POOL

BUILDING

BLDG. 147G

BLDG. 147

PROJECT LIMIT

BUILDING

BLDG. 146

NEW ANNEX

BLDG. 148

EXISTING BUILDING 148

MAIN

ENTRANCE

DRIVEWAY

PROJECT LIMIT

T O S H E E R A V E . S T R R E T # 3

N PROPOSAL SITE PLAN IMPORTANT NOTES:

PR

O

JE

C

T

LI

M

IT

PR

OJE

CT

L

IM

IT

AS-BUILT SET

DATED: 31 May 2024

02 40 C-1

AutoCAD SHX Text

EXISTING SIDEWALK TO REMAIN

AutoCAD SHX Text

EXISTING SIDEWALK TO REMAIN

AutoCAD SHX Text

EXISTING SIDEWALK TO REMAIN

EXISTING SIDEWALK TO REMAIN

PLAN VIEW COLUMN PLAN VIEW COLUMN PLAN VIEW COLUMN PLAN VIEW COLUMN

FOOTING DETAIL FOOTING DETAIL FOOTING DETAIL FOOTING DETAIL

CONCRETE FLOOR DETAIL FOUNDATION FOUNDATION

AS-BUILT SET

DATED: 31 May 2024

03 40 C-2A

CONCRETE SIDEWALK DETAIL

CONCRETE SIDEWALK DETAIL

AS-BUILT SET

DATED: 31 May 2024

04 40 C-3

GENERATOR

OFFICERS DINING AREA

DINING AREA

MECH. ROOM LOBBY

OFFICE SERVING AREA

DISH DROP OFF/

WASTE DISPOSAL

WALK IN COOLER

OFFICE

AREA

MAIN

ENTRANCE

FOOD PREP.

FOOD STORAGE DISH

WASHING

AREA

WALK IN FREEZER

WALK IN

COOLER

MECH.

ROOM

DEMOLITION NOTES: NOTES:

DEMOLITION PLAN

N

DEMOLITION LEGEND:

MITIGATION NOTES:

C O

N C

. S

LA

B

ST

O

R

AG

E

JA

N

IT

O

R

M

EN

R

ES

TR

O

O M

ST

O

R

AG

E

W O

M

EN

R

ES

TR

O

O M

ST

O

R

AG

E

R

ES

TR

O

O M

C O

O

LE

R

AS-BUILT SET

DATED: 31 May 2024

05 40 A-1

AutoCAD SHX Text

AutoCAD SHX Text

REMOVED EXISTING FIRE PANEL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DOOR TO BE REUSED.

AutoCAD SHX Text

AutoCAD SHX Text

(NOT IN CONTRACT)

(NOT IN CONTRACT)

SOUTH ELEVATION

EAST ELEVATION

WEST ELEVATION

ELEVATIONS DEMOLITION NOTES:

NOTES:

NORTH ELEVATION ELEVATION DETAIL

AS-BUILT SET

DATED: 31 May 2024

06 40 A-2

AutoCAD SHX Text

(REPAIRED BY OWNER)

(NOT IN CONTRACT)

SCULLERY

MEN

RESTROOM

OFFICERS DINING AREA

WOMEN

RESTROOM

DINING AREA

HAND WASH AREA

WALK IN COOLER

HALLWAY

MECH.

ROOM LOBBY

SERVING AREA OFFICE

AREA

STORAGE

ENTRANCE

ELEC.

ROOM

WALK IN FREEZER

MECH.

ROOM

SERVICE

ENTRANCE

FOOD STORAGE FOOD PREP.

WATER

HEATER/

SOFTENER

STO.

RESTROOM

SERVICE

AREA

PROPOSED FLOOR PLAN

N

LEGEND:

AS-BUILT SET

DATED: 31 May 2024

07 40 A-3

AutoCAD SHX Text

EXISTING WALL EXTENDED TO THE CEILING WITH GYPSUM BOARD AND METAL FRAME

AutoCAD SHX Text NEW HOLLOW METAL DOOR SINGLE DOOR INSTALLED, 3' X 6'-8" WITH FRAME, LOCKSET, HARDWARE & THRESHOLD WITH NOTES 1,2,3,4,5,6, AutoCAD SHX Text

EXISTING WALL EXTENDED TO THE CEILING WITH CMU 6"

AutoCAD SHX Text

DRIVEWAY BUILT WITH REINFORCED STEEL #4 @ 10" AND 5" DEEP

AutoCAD SHX Text

SS.WH.

AutoCAD SHX Text

SS.DW.

AutoCAD SHX Text

PP-3

EXISTING SIDEWALK TO REMAIN

MEN WOMEN

RESTROOM RESTROOM

SCULLERY

OFFICERS

DINING AREA

HAND WASH AREA

DINING AREA

MECH. ROOM WALK IN COOLER

HALLWAY

LOBBY SERVING AREA

OFFICE

AREA

WALK IN FREEZER

ENTRANCE STORAGE

MECH.

ROOM FOOD STORAGE EXISTING FOOD PREP.

SERVICE

ENTRANCE

WATER

HEATER/

SOFTENER

STO. REST.

LEGEND: NOTES:

REFLECTED CEILING PLAN

N

AS-BUILT SET

DATED: 31 May 2024

ELEC.

ROOM

08 40 A-4

AutoCAD SHX Text 9'-0" A.F.F.

AutoCAD SHX Text 9'-0" A.F.F.

AutoCAD SHX Text 9'-0" A.F.F.

AutoCAD SHX Text

EXISTING CEILING TILES

AutoCAD SHX Text

NEW CEILING TILES

AutoCAD SHX Text

NEW CEILING TILES

AutoCAD SHX Text

NEW CEILING TILES

AutoCAD SHX Text

NEW CEILING TILES

AutoCAD SHX Text

EXISTING CEILING TILES

AutoCAD SHX Text 2' x 2' - RECESSED FLUORESCENT FIXTURE

PP-3

ROOF SCOPE OF WORK:

ROOF DRAIN NOTE:

ROOF VENT PIPE (VTR)

TYPICAL CONCRETE SPLASH BLOCK DETAIL

NEW ANNEX ROOF PLAN RAIN LEADER DETAIL

EX

IS

TI

N

G R

O O

F

BU

IL

D

IN

G

AS-BUILT SET

DATED: 31 May 2024

09 40 A-5

SCULLERY

OFFICERS DINING AREA

DINING AREA

HAND WASH AREA

WALK IN COOLER

MECH.

ROOM LOBBY

OFFICE

AREA

HALLWAY

SERVING AREA

STORAGE

ENTRANCE

ELECTRICAL

ROOM

FOOD PREP.

WALK IN FREEZER

MECH.

ROOM

FOOD STORAGE

RESTROOM

WATER HEATER/

SOFTENER STORAGE

EQUIPMENT SCHEDULE

PROPOSED EQUIPMENT LAYOUT

N

NOTES:

AS-BUILT SET

DATED: 31 May 2024

10 40 A-6

AutoCAD SHX Text

SS.WH.

AutoCAD SHX Text

SS.DW.

PP-3

SOUTH ELEVATION

EAST ELEVATION

WEST ELEVATION

LEGEND:

NOTES:

NORTH ELEVATION ELEVATION DETAIL

AS-BUILT SET

DATED: 31 May 2024

11 40 A-7

AutoCAD SHX Text L

AutoCAD SHX Text

EXSITING METAL STAIR, SCRAPPED AND PAINTED

AutoCAD SHX Text

GLASS MULLIONS DIVISOR ELIMINATED AND FROSTED GLASS FILM INSTALLED

AutoCAD SHX Text

OPENING FILLED WITH CMU, CEMENT PLASTER AND PAINTED

OPEN TO BEYOND

LEGEND:

NOTES:

SERVICE

ENTRANCE

SECTION AA

LEGEND:

SECTION BB

AS-BUILT SET

DATED: 31 May 2024

12 40 A-8

AutoCAD SHX Text

NEW WALL, DENGLASS

AutoCAD SHX Text

NEW WALL, DENGLASS

AutoCAD SHX Text

OPEN TO BEYOND

FIRE CONTROL PANEL

HAND WASH AREA

SERVING AREA

ELEVATION 1

DETAIL 2:ELEVATION 1

DETAIL 3: CEMENT BOARD WALL

NOTES:

ELEVATION 2 DETAIL 2: ELEVATION 2 AS-BUILT SET

DATED: 31 May 2024

13 40 A-9

OPEN TO BEYOND

S T O R E F R O N T S & W I N D O W S C H E D U L E WINDOW NOTES

WINDOW ELEVATION

F I N I S H S C H E D U L E GENERAL NOTES:

PAINT NOTES:

DOOR ELEVATION

D O O R S C H E D U L E

TYPICAL DOOR JAMB DETAILS

LOCKSET SCHEDULE

F I N I S H L E G E N D

TYPICAL THRESHOLD DETAIL

WALL

NOTES:

CEILING

FLOOR

AS-BUILT SET

DATED: 31 May 2024

W

IN

D O

W

D O

O R

S C

H

ED

U

LE

14 40 A-10

AutoCAD SHX Text 4'-10

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HOLLOW METAL

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 6'-8"

AutoCAD SHX Text

SINGLE DOOR, WITH FRAME, LOCKSET, HARDWARE & THRESHOLD

AutoCAD SHX Text 1,2,3,4,5,6

AutoCAD SHX Text

EXISTING DOOR WAS RE-USED

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text

EXISTING DOOR WAS RE-USED

AutoCAD SHX Text

THREE (3)

AutoCAD SHX Text 6'-3

AutoCAD SHX Text

FIXED GLASS WINDOW

AutoCAD SHX Text 4'-9"

4'-9"

SERVICE

ENTRANCE

ROOF

EF-06

NEW

SB101

SB101

EF-08

NEW

EF-07

NEW

SF-07

NEW

SF-08

NEW

CU-01

SB101

SB101

3'-3"

1'-2"

4'-11"

5'-1"

5'-2"

'-3

0' -1

1"

3' -3

9'-8"

'-7

2'-8" 5'-4" 5'-5"

'-8

3'-5" 5'-1" 5'-1" 3'-5" 4'-5" 5'-8"

'-4

'-7

EXISTING

BEAM

BELOW

EXISTING

BEAM

BELOW

A

SB102

C

SB102

B

SB102

D

SB102

F

SB102

E

SB102

14'-73 8"

5' -9

7 16

CURB TO CONCRETE ANCHORS

UNIT

SIZE

TOTAL AMOUNT OF

ANCHOR BOLTS REQUIRED ANCHOR BOLTS DIAMETER

EF-06

EF-07

EF-08

8"

SF-07

SF-08

CU-01

8"

8"

8"

8"

2"

NOTES:

1. INSTALL 4 STEEL WIRE ROPE TIE DOWN PER UNIT 3

8" DIA.

2. ATTACH EQUIPMENT TO CURB AS PER MANUFACTURER

INDICATIONS.

3. NOTE GROUT:

UTILIZE HIGH EARLY STRENGTH PREMIXED NON-SHRINK

GROUT. APPLY SIKADUR 32 BONDING AGENT ON INTRFACE

BETWEEN EXISTING CONCRETE AND NEW MORTAR.

* 3

8" KWIK BOLT TZ EMBEDMENT DEPTH 2"

INSTALLER TO

SEAL AS

REQUIREDROOF CURB

M

IN

M

IN

2 7 8"

MIN.

8" KWIK BOLTS

2'-11 2"

'-1

1 2"

1'-111 2"

'-1

2"

2'-71 2"

'-7

1 2"

3'-71 2"

'-0

1 8"

1'-31 2"

'-3

1 2"

EXHAUST VENTILATOR

ABOVE. FOR DETAILS

SEE MECHANICAL DWGS.

SUPPLY PACKAGE

VENTILATOR. FOR

DETAILS SEE

MECHANICAL DWGS.

R O

O F

O

PE

N

IN

G

EXHAUST VENTILATOR

ABOVE. FOR DETAILS

SEE MECHANICAL DWGS.

'-2

10'-1"

SUPPLY PACKAGE

VENTILATOR. FOR

DETAILS SEE

MECHANICAL DWGS.

EXHAUST VENTILATOR

ABOVE. FOR DETAILS

SEE MECHANICAL DWGS.

REQUIRED OPENING

FOR EQUIPMENT

LIMIT OF SELECTIVE

DEMOLITION. DEMOLISH

CONCRETE ONLY. LEAVE

REBAR INTACT.

EXISTING REBAR

CUT EXIST. REBAR AT

CENTERLINE OF OPENING

NEW PERIMETER REBAR.

EXISTING REBAR

FINISH PERIMETER

OPENING WITH GROUT

SEE NOTE 1

4"

G

SB101

G

SB101

G

SB101

H

SB101

4"

4"

EX

H

AU

ST

V

EN

T.

BA

SE

'-0

EX

H

AU

ST

V

EN

T.

C

U R

B

'-8

'-7

1 2"

VE

N

TI

LA

TO

R

B

AS

E

4"

'-8

1 8"

VE

N

TI

LA

TO

R

C U

R B

R O

O F

O

PE

N

IN

G

ROOF OPENINGROOF OPENING

R O

O F

O

PE

N

IN

G

'-6

EX

H

AU

ST

V

EN

T.

BA

SE

'-2

EX

H

AU

ST

V

EN

T.

C U

R B

ROOF OPENING

4"

4"

R O

O F

O

PE

N

IN

G

ROOF OPENING

'-4

VE

N

TI

LA

TO

R B

AS

E

'-0

VE

N

TI

LA

TO

R C

U R

B

R O

O F

O

PE

N

IN

G

ROOF OPENING

1'-8"

EXHAUST VENT.BASE

'-4

EX

H

AU

ST

V

EN

T.

C U

R B

SEE SECTION H

BELOW

REQUIRED OPENING

FOR EQUIPMENT

LIMIT OF SELECTIVE DEMOLITION. DEMOLISH

CONCRETE ONLY. LEAVE REBAR INTACT.

CUT EXIST. REBAR AT CENTERLINE

NEW PERIMETER

REBAR

FILL WITH GROUT AND

PRODUCT SEE NOTE 1

4" 4" OPENING VARIES

N

R O

O F

O

PE

N

IN

G S

PL

AN

SCALE:

PARTIAL ROOF OPENINGS PLAN

3/16"=1'-0"

SCALE:

SECTIONG

3"=1'-0"SB101

SCALE:

DETAIL2

3/4"=1'-0"

EF-08 EXHAUST VENTILATOR FAN AND

SF-08 SUPPLY PACKAGE VENTILATOR

SB101

SCALE:

DETAIL3

3/4"=1'-0"

EF-06 EXHAUST VENTILATOR FAN

SB101

SCALE:

DETAIL1

3/4"=1'-0"

EF-07 EXHAUST VENTILATOR FAN AND

SF-07 SUPPLY PACKAGE VENTILATOR

SB101

SCALE:

DETAIL4

1/2"=1'-0"

CU-01

SB101

SCALE:

TYPICAL OPENING CONSTRUCTION DETAIL

3/4"=1'-0"

SCALE:

SECTIONH

1 1/2"=1'-0"SB101

6"

6"

18’’

1’

AS-BUILT SET

DATED: 31 May 2024

2020-01-14 3/16"=1'-0"

15 40

SB101

AutoCAD SHX Text

AND BEND AT 90°

AutoCAD SHX Text

OF OPENING AND BEND AT 90°

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CU

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

1. Colocar angular ¼" en acero (con

AutoCAD SHX Text protección de corrosión) con una

AutoCAD SHX Text dimensión de 4" X 4". se colocarán tres

AutoCAD SHX Text angulares de cada lado.

AutoCAD SHX Text

2. Colocar threaded rod (stainless steel) de

AutoCAD SHX Text ½"

AutoCAD SHX Text de diametro que traspase la base de la

AutoCAD SHX Text condensadora. Con sus arandelas y tuercas

AutoCAD SHX Text en stainless steel. Aplicar threadlocker (de

AutoCAD SHX Text alta resistencia ) en los rod.

AutoCAD SHX Text

3. Colocar threaded rod (stainless steel) ½"

AutoCAD SHX Text de diametro que traspase el suelo un

AutoCAD SHX Text mínimo de dos pulgadas. Aplicar

AutoCAD SHX Text threadlocker (de alta resistencia ) en los rod.

AutoCAD SHX Text

4. Colocar el "vibration isolation pad" de

AutoCAD SHX Text minimo ¼" de grosor, que cubra 18"

AutoCAD SHX Text debajo del marco de soporte de la maquina

AutoCAD SHX Text he incluya el angular. El pad debe tolerar

AutoCAD SHX Text más de 900 libras en cada punto .

AutoCAD SHX Text

5. Colocar threaded rood con epoxy.

Instrucciones

2'-8" 5'-4" 5'-5"

(2)HILTI ANCHOR

BOLTS

EXISTING

CONC.

BEAM

EXISTING

CONC.

SLAB

8" Ø BOLT, NUT

AND WASHER

(2)HILTI ANCHOR

BOLTS

W8x10

ROOF OPENING

HSS 3x3x1/4x3"(TYP.)NON-SHRINK GROUT(TYP.) PL 6x6x1

4" (TYP.) 3

16"

TYP.

5'-2"

EXISTING

CONC.

BEAM

16"

TYP.

W8x10

L 4x4x 3 8"x5"

(2)HILTI ANCHOR

BOLTS

8" Ø BOLT, NUT

AND WASHER

2'-8"

8" Ø BOLT, NUT

AND WASHER

W8x10

ROOF OPENING PL 6x1

4" (TYP.)

LENGTH VARIES

L 4x4x 3 8"x5"

3'-4"

PL 6x1

" (TYP.)

LENGTH VARIES

HSS 3x3x1/4x3"(TYP.)

16"

TYP.

W8x10

HSS 3x3x1/4x3"(TYP.)

W8x10

8" Ø BOLT, NUT

AND WASHER

NON-SHRINK

GROUT(TYP.)

NON-SHRINK

GROUT(TYP.)

EXISTING CONC.

SLAB

EXISTING

CONC.

SLAB

EXISTING

CONC.

BEAM

4'-1"

EXISTING CONC.

BEAM

(2)HILTI ANCHOR

BOLTS

HSS 3x3x1/4x3"(TYP.)

16"

TYP.NON-SHRINK

GROUT(TYP.)

EXISTING

CONC.

SLAB

W8x10 W8x10

3'-41 2" 5'-1" 5'-1"

(2)HILTI ANCHOR

BOLTS EXISTING CONC.

BEAM

EXISTING CONC.

SLAB

8" Ø BOLT, NUT

AND WASHER

(2)HILTI ANCHOR

BOLTS

W8x10

ROOF OPENING

HSS 3x3x1/4x3"(TYP.)

NON-SHRINK

GROUT(TYP.) PL 6x6x1

4" (TYP.) 3

16"

TYP.

PL 6x1

4" (TYP.)

LENGTH

VARIES

EXISTING CONC.

BEAM

EXISTING CONC.

SLAB

PL 6x6x1

4" (TYP.)NON-SHRINK

GROUT(TYP.)

ROOF OPENING5

8" Ø BOLT, NUT

AND WASHER

3'-5" 4'-5" 5'-8" 7" 7"

PL 6x1

4" (TYP.)

LENGTH VARIES

PL 6x1

4" (TYP.)

LENGTH VARIES

PL 6x1

4" (TYP.)

LENGTH

VARIES

7" 7"

NOTES:

1. STOP APPLY RED-OXIDE PRIMER ON ALL STEEL SURFACES.

INSPECT AND REPAINT ANY DAMAGED SURFACE DURING

INSTALLATION PROCESS.

3" 3"

6x1

4" STEEL PLATE, LENGTH VARIES.

THIS BASE PLATE APPLIES ONLY

BELOW ROOF SLAB

VARIES

1" 4"

1" 4" 1"

6x6x1

2" STEEL PLATE.

THIS BASE PLATE

APPLIES ONLY ABOVE

ROOF SLAB & BEAMS

4"

16"

TYP.

L 4x4x5x3 8"

PROVIDE (2) HOLES

TO ANCHOR BOLTS

TO EXIST. WALL

SB102

N

SCALE:

SECTIONA

3/4"=1'-0"SB101 SCALE:

SECTIONC

3/4"=1'-0"SB101

SCALE:

SECTIOND

3/4"=1'-0"SB101

SCALE:

SECTIONB

3/4"=1'-0"SB101

SCALE:

SECTIONE

3/4"=1'-0"SB101

SCALE:

SECTIONF

3/4"=1'-0"SB101

SCALE:

TYPICAL BASE PLATES DETAILS

1 1/2"=1'-0"

AS-BUILT SET

DATED: 29 May 2024

S T

R U

C T

U R

A L

D E

T A

IL

S

AS-BUILT SET

DATED: 31 May 2024

NEW ANNEX FOUNDATION PLAN NEW ANNEX STRUCTURAL ROOF PLAN

N N

LEGEND:

17 40 S-1

A A

PLAN

SECTION A-A SECTION B-B

FOUNDATION FOUNDATION FOUNDATION FOUNDATION

A A

PLAN

SECTION A-A SECTION B-B

FOUNDATION FOUNDATION FOUNDATION FOUNDATION

FOUNDATION BEAM SECTION BEAM SECTION BEAM SECTION BEAM SECTION FLASHING DETAIL

B B

B B

18 40 S-2

STRUCTURAL NOTES

RING TIE DETAILS

REINFORCED CONCRETE BLOCK WALL DETAIL

TYPICAL CMU ANCHORAGE

AT INTERSECTION WALL

TYPICAL CMU ANCHORAGE

AT CORNER WALL

TYPICAL REINFORCEMENT DETAIL AT OPENINGS

TYPICAL REINFORCEMENT

AT 8" CMU WALL

TYPICAL REINFORCEMENT

AT 6" CMU WALL

AS-BUILT SET

DATED: 31 May 2024

19 40 S-3

NEW METAL FACE &GATE AT EAST ELEVATION

SCALE: 3/8"=1'-0"

NEW METAL FACE & GATE AT WEST ELEVATION

SCALE: 3/8"=1'-0"

METAL CANE & PADLOCK DETAIL

SCALE: 3/4"=1'-0"

KEY-NOTE LEGEND:

1 1

1 2

1 2 1

SD-2

SD-2

SD-2

SD-2

2 6

4' -0

2"

1' -1

0"

1'-0"

3' -0

3 8" 9"

8"

4 1/2" 7"

8"

2"

SD-2

6'-0 1/4" 2"

2'-11 1/4" 2"

18'-0 3/4" 5'-10 1/2"

2' -0

2'

-0

2' -0

1'

-9

1. METAL SHEET PANEL.

2. 2" x 2" METAL TUBE.

3. 2"x2" METAL POST

4. METAL CANE.

5. PADLOCK

6. 1" x 1" METAL TUBE.

7' -8

1"

7' -9

6'-0 1/4" 6'-0 1/4" 2'-11 1/4"

AS-BUILT SET

DATED: 31 May 2024

20 40

SD-1

SE

R

VI

C

E

AR

EA

M

ET

AL

S H

EE

T

EL

EV

AT

IO

N S

AN

D

D

ET

AI

L

P-2

P-2

P-1 P-1

P-1 P-1

P-5

P-5

P-2

P-2

P-7

P-8

NEW

F.D.

NEW

F.D.1

NEW

F.D.2

FC0.-4

3" F.D.

P-6

FC0.-2

FD.-1 FC0.-3

NEW

F.D.1

ENTRANCE FD.-2

P-4

LEGEND:

P-2

F.C.O.-1

FD.-2

P-3 P-3 P-1

FC0.-1 F.C.O.-1

SERVICE

AREA

NOTES:

NEW

F.D.2

PROPOSED PLUMBING FLOOR PLAN

N

AS-BUILT SET

DATED: 31 May 2024

21 40 P-1

AutoCAD SHX Text 2.5"

2.5"

PLUMBING NOTES: BATHROOM FIXTURES SCHEDULE

PLUMBING SYMBOLS:

WALL MOUNTED HOSE BIBB ROOF VENT PIPE THROUGH SLAB

PLUMBING ABBREVIATIONS:

TYPICAL CLEAN-OUT FLUSH W/ FLOOR OR GRADE TYPICAL FLOOR DRAIN W/ P-TRAP

AS-BUILT SET

DATED: 31 May 2024

22 40 P-2

AutoCAD SHX Text (N.I.C.)

AutoCAD SHX Text (N.I.C.)

AutoCAD SHX Text (N.I.C.)

AutoCAD SHX Text (N.I.C.)

AutoCAD SHX Text (N.I.C.)

AutoCAD SHX Text (N.I.C.)

(N.I.C.)

LUMINARIES FLOOR PLAN

N

AS-BUILT SET

DATED: 31 May 2024

23 40 E-1

AutoCAD SHX Text

SS.WH.

AutoCAD SHX Text

SS.DW.

AutoCAD SHX Text

PP-3

AutoCAD SHX Text

SS-AHU1

AutoCAD SHX Text

VFD

AC COMM. BOXES

POWER FLOOR PLAN

AS-BUILT SET

DATED: 31 May 2024

24 40 E-2

ELECTRICAL SYMBOLS LEGEND:

DATED: 31 May 2024

25 40 E-3

HEAVY DUTY SAFETY SWITCH. SEE SCHEDULE FOR DETAILS. MOUNT TOP OF SWITCH AT

5'-0" A.F.F. CONTRACTOR SHALL PROVIDE ALL REQUIRED MOUNTING HARDWARE.

SINGLE POLE SWITCH, 20A, 120/277V. WITH PLASTIC COVER PLATE.

HOMERUN TO PANELBOARD. NUMBER OF CIRCUITS INDICATED BY NUMBER OF ARROWS.

NUMBERS AND LETTERS INDICATE CIRCUITS NUMBER AS PER PANEL SCHEDULE.

LEGEND:

NEW PANELBOARD 6'-6" A.F.F. SEE SCHEDULE FOR DETAILS.

NOTES:

1. NEW PANEL PP-3 WILL BE CONNECTED TO PANEL MDP (EXISTING)

WITH 2 SETS OF 4 #250 KCMIL AND 1 #1/0 IN A 3" EMT CONDUIT EACH

SET.

2. CONTRACTOR SHALL PROVIDE A 3P, 400A, 65 KAIC CIRCUIT BREAKER AT

PANEL MDP-1.

3. ALL INDOOR ELECTRICAL CONDUITS SHALL BE EMT (NOT EXPOSED TO PHYSICAL

DAMAGE).

4. ALL OUTDOOR ELECTRICAL CONDUITS SHALL BE RGS.

N

EXISTING PANELBOARD TO REMAIN.

E

S C

H E

D U

LE

S

A N

D L

E G

E N

D

M, RAMOS

M. FLORES

2020-01-14 NTS

AS-BUILT SET

DATED: 31 May 2024

J. PRATS

26 40

EP001

E

LE

C T

R

IC

A L

FL

O

O R

P

LA

N

EAEA

EF-01

AHU-01

EF-02

EF-04 EF-03

MECH.

ROOM VAV-05

RA

SASASASASA

SA

SA

SA

SA

SA

SA

TO LT

SWITCH

TO LT

SWITCH

TO LT

SWITCH

VAV-02

VAV-03

VAV-04

VAV-06

TO PP-3 #20

VAV-01

PP-3

TO PP-3

#2,4,6

MDP-1

E

N

F14

LAPTOP

AREA

VFD SS#4

NEW COMMUNICATION

CONDUIT 3/4"

CNTROL &

COMMUNICATION BOX

27 40

EP101

AutoCAD SHX Text

SS.WH.

SS.DW.

SERVICE

ENTRANCE

SERVICE

AREA

ROOF

EF-06

NEW

EF-08

NEW

EF-07

NEW

SF-07

TO PP-3

#14,16,18

SS-1

SS-3

SS-2

SS-4

SF-08

NEWCU-01

SS-6

TO PP-3.

#9,11,13

TO PP-3

#3,5,7

TO PP-3

#8,10,12

TO PP-3

#15,17,19

TO PP-3 #1

SS-7

N

E

LE

C T

R

IC

A L

R O

O F

P

LA

N

AS-BUILT SET

DATED: 31 May 2024

NEW FREEZER &

REFRIGERATOR

CONDENSING UNITS

8' -6

4'-6"

6' -9

5'-10"

5' -5

3'-7"

NEW

28 40

EP102

M. RAMOS

M.FLORES

J. PRATS

CONDUIT, TYP MINERAL WOOL

(FIRMLY PACKED)

FIRESTOP SEALANT

(3/8") MAX

9.52mm

JUNCTION BOX

(SIZE AS REQUIRED)

SPRING

NUT, TYP

INTEGRAL GALVANIZED

LIPPED STEEL MOUNTING

CHANNEL, TYP.

ROOF SLAB,

TYP. STEEL EXPANSION

ANCHOR, TYP

GENERAL NOTES:

LENGTH AS REQUIRED

LOCKING SQUARE

WASHER & LOCKNUT

WASHER &

LOCKNUT

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

TO EQUIPMENT

1 1/2" x 1 1/2" CHANNEL

SAFETY SWITCH

3" 6"

1/4" WELD

6" 3"

AS REQUIRED

SWITCH

6"3" 3"

AP

PR

O X.

4' -6

AS

R

EQ

U

IR

ED

(MINIMUM) (MINIMUM)

SCALE:

DETAIL1

NOT TO SCALE

ROOF SLAB PENETRATION

EP501 SCALE:

DETAIL1

NOT TO SCALE

CONDUIT TRAPEZE MOUNTING

EP501 SCALE:

DETAIL1

NOT TO SCALE

SAFETY SWITCH MOUNTING

EP501

1 2

6' -6

14"

"MDP-1 PP-3

SCALE:

ELECTRICAL RISER DIAGRAM

NOT TO SCALE

EXISTING MDP-1 PANEL 120/240V, 3P, 4W, 800A,

65 KAIC.

NEW PP-3 PANEL 120/208V, 3P, 4W, 400A, 22 KAIC

IN A NEMA 1 ENCLOSURE.

4#250 KCMIL THWN AND 1#1/0 THW-600V IN A 3"

EMT CONDUIT.

ELECTRICAL RISER DIAGRAM LEGEND:

9.52mm (3/8") MIN

GALVANIZED

THREADED ROD,

TYP.

REFER TO PLANS FOR

QUANTITY & SIZE OF

CONDUITS

CONDUIT

CLAMP. SIZE

AS REQUIRED

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

1. INTEGRAL GALVANIZED LIPPED STEEL

MOUNTING CHANNEL LONGER THAN 915mm (36")

SHALL BE INSTALLED WITH A CENTER SUPPORT

ROD.

2. FASTEN THREADED ROD TO STRUCTURE BY

APPROVED METHOD PER SPECIFICATION 26 05 33,

RACEWAY AND BOXES FOR ELECTRICAL

SYSTEMS. FIELD VERIFY EXACT CONDITIONS.

3. FOR TRAPEZE INSTALLATIONS IN SEISMIC

AREAS REFER TO SPECIFICATION SECTION

260529 - HANGERS AND SUPPORTS FOR

ELECTRICAL SYSTEMS.

1/2" x 3/4"

CHANNEL

LIQUIDTIGHT

FLEXIBLE

CONDUIT

1/2"Ø EXPANSION BOLTS

FLOOR OR ROOF LEVEL

1'-6" x 1'-0" x 1/4"

STAINLESS

STEEL PLATE

1/2"Ø

EXPANSION

BOLTS

FINISHED FLOOR

AS-BUILT SET

DATED: 31 May 2024

EL

EC

TR

IC

A L

D

ET

A

IL

S

29 40

EP501

G

EN

ER

AL

S

YM

BO

LS

, N O

TE

S

AN

D

A

BB

R

EV

IA

TI

O N

S

HVAC ABBREVIATIONS: HVAC SYMBOLS:

ACC

AD

AFF

ADJ

ACU

AHU

AP

AUX

BD

BDD

BFP

BHP

BOD

BOP

BTU

BTUH

CC

CD-"X"

CG-"X"

CH

CHWS

CHWR

CLG

CL

CR

CFM

CMU

COND

CONN

CP

CT

CTWS

CTWR

CU

CU FT

DET

DH

DIA

DIAG

DN

DIM

DL

DPT

DWG

EA

EFF

EP

EF

ER

EG

ET

EH

EXH

EXIST.

AIR COOLED CONDENSER

ACCESS DOOR

ADJUSTABLE

ABOVE FINISHED FLOOR

AIR CONDITIONING UNIT

AIR HANDLING UNIT

ACCESS PANEL

AUXILIARY

BYPASS DAMPER

BACKDRAFT DAMPER

BACK FLOW PREVENTER

BRAKE HORSEPOWER

BOTTOM OF DUCT

BOTTOM OF PIPE

BRITISH THERMAL UNIT

BTU PER HOUR

COOLING COIL

CEILING GRILLE

CEILING DIFFUSER

"X"=THROW DIRECTIONS NUMBERS

CHILLER

CHILLED WATER SUPPLY

CHILLED WATER RETURN

CEILING

CENTER LINE

CEILING REGISTER

CUBIC FEET PER MINUTE

CONCRETE MASONRY UNIT

CONDENSATE

CONNECTION

CONTROL PANEL

COOLING TOWER

COOLING TOWER WATER RETURN

COOLING TOWER WATER SUPPLY

CONDENSING UNIT

CUBIC FEET

DETAIL

DEHUMIDIFIER

DIAMETER

DIAGRAM

DIMENSION

DOWN

DOOR LOUVER

DIFFERENTIAL PRESSURE

TRANSMITTER/SWITCH

DRAWING

EXHAUST AIR

EFFICIENCY

ELECTRIC-PNEUMATIC SWITCH

EXHAUST AIR FAN

EXHAUST REGISTER

EXHAUST GRILLE

EXPANSION TANK

ELECTRICAL HEATER

EXHAUST

EXISTING

NC

N.I.C

No.

NS

NO

N.T.S

OA

OAL

OBD

OC

OPER

OPNG

P

PE

PH

PLN

PL

QTY

NORMALLY CLOSED (FAIL SAFE CLOSED)

NOT IN CONTRACT

NUMBER

NORMALLY OPEN (FAIL SAFE OPEN)

NATIONAL STANDARD

NOT TO SCALE

OUTSIDE AIR

OUTSIDE AIR LOUVER

OPPOSED BLADE DAMPER

ON CENTER

OPERATING

OPENING

PUMP

PNEUMATIC-ELECTRIC SWITCH

PHASE

PLENUM

PLATE

QUANTITY

LBS

LD

LG

LIQ

LL

LR

MAN

MATL

MAX

MBH

MCC

MD

MFR

MIN

MOD

GA

GALV

GPM

GV

HL

HOA

HP

HZ

IH

IN

GALLONS PER MINUTE

GAUGE

GALVANIZED

GRAVITY RELIEF VENT

HIGH LIMIT

HAND-0FF-AUTOMATIC SWITCH

HORSE POWER

HERTZ

AIR INTAKE HOOD

INCHES

POUNDS

LINEAR DIFFUSER

LONG

LIQUID

LOW LIMIT

LONG RADIUS

MANUAL

MATERIAL

MAXIMUM

1000 BTU PER HOUR

ELBOW WITH TURNING VANES

MOTOR CONTROL CENTER

MOTORIZED DAMPER

MANUFACTURER

MINIMUM

MODEL

TEMP

TG

TIP

TOC

TOD

TOP

TOS

TP

TYP

UH

U.O.N

V

VAV

VD

V.V

W/

W/O

WCC

WG

WS

WT

TEMPERATURE

TRANSFER GRILLE

TIE-IN POINT

TOP OF CONCRETE

TOP OF DUCT

TOP OF PIPE

TOP OF STEEL

TOTAL PRESSURE

TYPICAL

UNIT HEATER

UNLESS OTHERWISE NOTED

VOLTS

VARIABLE AIR VOLUME

VOLUME DAMPER

VARIABLE AIR VOLUME BOX

WITH

WITHOUT

WATER COOLED CONDENSER

WATER GAUGE

WALL SUPPORT

WEIGHT

CODES:

1. PR BUILDING CODE 2018

2. NG PAM 415.12

3. NGB-DG 415-5

4. VCF 4-010-01

5. NFPA 70

F

FAI

FC

FD

FLEX.

FOB

FOT

FSD

FUT

DEGREES FAHRENHEIT

FRESH AIR INTAKE

FAN COIL UNIT

FIRE DAMPER

FLEXIBLE

FLAT ON BOTTOM

FLAT ON TOP

COMBINATION FIRE/SMOKE DAMPER

FUTURE

R

RA

REF

RF

RG

RH

RHC

RHWR

RHWS

RL

RM

RPBP

RPM

RR

PRV

SA

SCH

SE

SF

SHT

SL

SOL

SPD

SQ HD

SP

SPECS

SR

SS

STD

STT

RADIUS

REFERENCE

RETURN AIR

D/L

RETURN AIR FAN

RETURN AIR GRILLE

RADIANT HEATER

REHEAT COIL

REFRIGERANT (LIQUID) LINE

REHEAT WATER RETURN

REHEAT WATER SUPPLY

ROOM

REDUCED PRESSURE BACKFLOW

REVOLUTIONS PER MINUTE

RETURN AIR REGISTER

PREVENTER

SD

SUPPLY AIR

SCHEDULE

SMOKE EXHAUST

SUPPLY FAN

SHEET

SUCTION LINE

SOLENOID VALVE

SPLITTER DAMPER

SQUARE HEAD

STATIC PRESSURE

SPECIFICATIONS

SUPPLY REGISTER

STAINLESS STEEL

STANDARD

SOUND TRAP, SOUND ATTENUATOR

24"x12"

DAMPER - MOTOR OPERATED

VARIABLE AIR VOLUME BOX

MOD

DAMPER - MOTORIZED VORTEX

DAMPER OPERATOR-MANUAL OVERRIDE

BRANCH CONNECTION-SUPPLY & RETURN

SPLITTER DAMPER W/ ADJUSTING ROD

T

DIRECTION OF FLOW

8. THE CONTRACTOR SHALL TAKE EVERY PRECAUTION IN ORDER TO MINIMIZE OR

DUCT - ACOUSTIC LINER

T

DUCT SIZE - FIRST DIMENSION

IS FOR SIDE SHOWN

DUCT - SUPPLY AIR

DUCT - EXHAUST OR RETURN AIR

DUCT - OUTSIDE AIR

DUCT - FLEXIBLE

DUCT - FLEXIBLE CONNECTION

DUCT - TRANSITION

SIZE SR

CFM

H

LS

FS

THERMOSTAT, REMOTE BULB

HUMIDISTAT

AIR FLOW SWITCH

LIMIT SWITCH

ELIMINATE THE TRANSMISSION OF NOISE OR VIBRATION FROM THE EQUIPMENT.

PIPING SYSTEM OR DUCT SYSTEM TO THE CONDITIONING SPACE.

SPECIFICATION AND/OR MANUFACTURER MODEL OR CATALOG NUMBER.

9. ALL EQUIPMENT, MATERIALS AND ACCESSORIES SHALL BE AS PER THE INDICATED.

10. UNLESS OTHERWISE NOTED IN DRAWINGS AND/OR SPECIFICATIONS ALL

EQUIPMENT AND ACCESSORIES SHALL BE FURNISHED AND INSTALLED BY THE

11. UNLESS OTHERWISE NOTED FOR ALL EQUIPMENT OUTSIDE BUILDING AND ON

LARGER CONCRETE SLABS OUTSIDE BUILDING, A 4-INCH THICK CONCRETE

CONTRACTOR.

HOUSEKEEPING PAD SHALL BE PROVIDED.

12. COORDINATE ROOF OPENING LOCATIONS FOR

MECHANICAL AND ELECTRICAL CONNECTIONS.

13. COORDINATION DURING THE CONSTRUCTION PHASE: STRUCTURAL, ELECTRICAL

AND MECHANICAL CONTRACTORS MUST COORDINATE THEIR WORK IN ORDER TO

PROVIDE THE REQUIRED CLEARANCES AND RIGHT OF WAYS FOR EACH OF THE

TRADES.

14. DESIGN WAS DONE BASED ON THE INTERNATIONAL CODES. CONTRACTOR MUST

PERFORM CONSTRUCTION AND INSTALLATIONS COMPLYING WITH THE CODES, STANDARDS

AND REGULATIONS INDICATED IN THE FOLLOWING 2018 INTERNATIONAL BUILDING CODE AND

INTERNATIONAL MECHANICAL CODE,

15. INSULATE ALL SUCTION REFRIGERANT PIPING WITH ARMAFLEX OR SIMILAR INSULATION.

16. INSULATE ALL CONDENSATE PIPING WITH INSULATION.

17. DUCT CONSTRUCTION AND INSTALLATION SHALL BE FLAT ON BOTTOM .

18. COORDINATE LOCATION OF BMS CENTRAL MONITORING AND CONTROL STATION WITH

FACILITIES PERSONNEL.

SUPLLY DIFFUSER

U/C

FD

3 HR FD

G

VD

AIR FLOW SUPPLY

AIR FLOW EXHAUST/RETURN

AIR FLOW THROUGH UNDERCUT DOOR

AIR FLOW THROUGH DOOR LOUVER

DAMPER - FIRE 3 HR RATED

DAMPER - FIRE 1HR RATED

DAMPER - MANUAL VOLUME

DAMPER - GRAVITY OPERATED

M FAN - CENTRIFUGAL

RISE OR DROP (IN RESPECT

TO AIR FLOW)

TRANSITION - RECTANGULAR TO ROUND

ROUND DUCT UP

ROUND DUCT DOWN

REDUCER (CONCENTRIC)

CAPPED DUCT

3. SECTIONS OF DUCT SHALL BE TESTED FOR LEAKAGE AT THE

4. DUCT WORK SUPPORTS SHALL COMPLY WITH SMACNA RECOMMENDATIONS

5. NO ELBOW SHALL BE MADE WITH AN INSIDE RADIUS OF LESS THAN

FOR TYPE OF DUCT CONSTRUCTION.

INDICATED PRESSURE CLASS.

THE WIDTH OF THE DUCT. SHALL ANY TURN BE NECESSARY WITH

INSIDE RADIUS LESS THAN 3/4 DEPTH OF THE DUCT, THEY MUST

BE FITTED WITH DOUBLE THICKNESS MULTIPLE VANES.

6. HVAC DUCT MATERIALS SHALL BE GALVANIZED STEEL, UNLESS

OTHERWISE INDICATED. EVS OR FUME HOOD EXHAUST DUCTWORK

SHALL BE CHEMICAL CORROSION RESISTANT.

7. THE MECHANICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL ELECTRICAL

EXHAUST/RETURN REGISTER

THERMOSTAT

CONTROLS, SAFETY SWITCHES AND ACCESSORIES NOT INDICATED IN THE

ELECTRICAL DRAWINGS AND NECESSARY FOR THE PROPER OPERATION OF THE

EQUIPMENT IN ACCORDANCE WITH THE MECHANICAL EQUIPMENTS

MANUFACTURERS RECOMMENDATIONS AND THE NATIONAL ELECTRIC CODE.

GENERAL NOTES

1. DUCTWORK FOR THE VENTILATION SYSTEMS SHALL BE MANUFACTURED AND

2. DUCTS SHALL BE RECTANGULAR OR ROUND AS INDICATED IN THE

ASSOCIATION, INC. SMACNA (LATEST EDITION).

INSTALLED IN ACCORDANCE WITH THE DUCT CONSTRUCTION STANDARDS

OF THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL

DRAWINGS.

GENERAL NOTES

1. THIS IS A GENERAL ABBREVIATION LIST. SOME

ABBREVIATIONS MAY NOT BE USED IN THIS PROJECT.

AS-BUILT SET

DATED: 31 May 2024

30 40

MH001

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

" X

EF-01 EF-02

EF-04 EF-03EF-05

OFFICERS DINING AREA

LOBBY

WOMEN

RESTROOM

MEN

RESTROOM

MECH.

ROOM

FOOD PREP.

STO.

RESTROOM

WALK IN FREEZER

WALK IN COOLER

SCULLERY

MECH.

GENERATOR

OFFICE

AREA

STORAGE

ELEC.

ROOM

DINING AREA

ENTRANCE

WATER

HEATER/

SOFTENER

HALLWAY

SERVICE

ENTRANCE

SERVICE

AREA

VAV-02

VAV-04

VAV-05

VAV-06

EF-08

EF-07

SF-07

EA

MK'UP

VAV-07

20" X 18"

12"x12" EA DUCT

UP TO EF-06 AT

ROOF

CD-1 12"Ø

305 CFM SA

CD-1 12"Ø

305 CFM SA

EG-1 14"x12"

600 CFM EA

"x

6"

RG-1 10"Ø

220 CFM RA

12"x6"

"x

44"x22"

"x

"FOOD

STORAGE

RG-3 48" X 30"

4344 CFM RA

44"x22"

36"x18"

RG-2 14"x12"

504 CFM RA

CD-1 12"Ø

405 CFM SA

CD-1 12"Ø

405 CFM SA

CD-1 12"Ø

405 CFM SA

CD-1 12"Ø

405 CFM SA

CD-3 10"Ø

230 CFM SA

CD-4 10"Ø

240 CFM SA

CD-1 12"Ø

440 CFM SA

CD-1 12"Ø

445 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 2'-0"

280 CFM SA

LSD-2

4 SLOTS 3/4" x 4'-0"

560 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

O AL-1 78"x12"

1,587 C

FM

O A

LRD-2

6 SLOTS 3/4" x 8'-0"

2,560 CFM RA

LRD-1

4 SLOTS 3/4" x 8'-0"

1,505 CFM RA

HAND

WASH

AREA

VAV-01

"x

"x

SERVING

AREA

"x

AHU-01

SF-08

CD-1 12"Ø

405 CFM SA

LSD-3

8 SLOTS 1" x 10'-0"

3520 CFM SA

LSD-3

8 SLOTS 1" x 10'-0"

3520 CFM SA

18" X 16"

"x

"x

12" X 18"

20" X 28"

20" X 18" 16" X 14" 10" X 8"24" X 20"

"x

"x

14" X 12" 12" X 10"

" X

0"

12" X 6"

10" X 8"

12" X 10" 12" X 6"

18" X 10" 14" X 10"

" X

16" X 6"16"x16"

22" X 16"26" X 20" 22" X 16"

28" X 26"

"x

"x

12" X 10"

"x

"x

EG-3 18-3/4" X 13-3/4"

313 CFM EA

EG-3 18-3/4" X 13-3/4"

313 CFM EA

EG-3 18-3/4" X 13-3/4"

313 CFM EA

EG-3 18.75" X 13.75"

313 CFM EA

EG-3 18.75" X 13.75"

313 CFM EA

16"x10"

"x

"x

EAL-1 EAL-1

EAL-1 EAL-1 EAL-1

3HRFD

3HRFD 3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD 3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD 3HRFD

3HRFD

26"x10"

"x

"x

"x

"x

VAV-03

T

T

T

T

T

T

TVAV-02

VAV-01

VAV-04

VAV-07

VAV-03

VAV-06

VAV-05

SLOPE

12" x 18"

ACCESS HATCH

18" X 16"

ACCESS HATCH

14" X 12"

MH401

B

MH401

A

"x

22" X 16"

" X

"3HRFD

DUCT UP 45º

N

FI

R

ST

F

LO

O

R P

LA

N

H

VA

C L

AY

O

U T

NOTE:

FOR AS-BUILT, REFER TO

INDIVIDUAL DRAWINGS OF

SUPPLY AND RETURN SYSTEMS

ON NEXT PAGES

AS-BUILT SET

DATED: 31 May 2024

LSD-1

4 SLOTS 3/4" x 4'-0"

560 CFM SA

LSD-1

4 SLOTS 3/4" x 4'-0"

560 CFM SA

"x

31 40

MH101

AutoCAD SHX Text

SS.WH.

AutoCAD SHX Text

SS.DW.

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

FOOD PREP.

OFFICE

HALLWAY

VAV-02

VAV-03

VAV-04

VAV-05

VAV-06

EF-08

CD-1 12"Ø

305 CFM SA

CD-1 12"Ø

305 CFM SA

12"x6"

44"x22"

44"x22"

CD-1 12"Ø

405 CFM SA

CD-1 12"Ø

405 CFM SA

CD-1 12"Ø

405 CFM SA

CD-1 12"Ø

405 CFM SA

CD-3 10"Ø

230 CFM SACD-4 10"Ø

240 CFM SA

CD-1 12"Ø

440 CFM SA

CD-1 12"Ø

445 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 8'-0"

1120 CFM SA

LSD-1

4 SLOTS 3/4" x 2'-0"

280 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

LSD-2

6 SLOTS 3/4" x 4'-0"

840 CFM SA

LSD-1

4 SLOTS 3/4" x 4'-0"

560 CFM SA

LSD-1

4 SLOTS 3/4" x 4'-0"

560 CFM SA

O AL-1 78"x12"

1,587 C

FM

O A

HAND

WASH

AREA

26"x10"

VAV-01

"x

"x

"x

"x

AHU-01

CD-1 12"Ø

405 CFM SA

"x

"x

12" X 18"

20" X 28"

20" X 18" 16" X 14" 10" X 8"24" X 20"

"x

14" X 12" 12" X 10"

" X

0"

12" X 6"

10" X 8"

12" X 10" 12" X 6"

18" X 10" 14" X 10"

" X

16" X 6"

26" X 20"

12" X 10"

"x

"x

"x

"x

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

3HRFD

"x

T

T

T

T

T

T

TVAV-02

VAV-01

VAV-04

VAV-07

VAV-03

VAV-06

VAV-05

MH101-1

MH101-1

MH101-1

MH101-1

MH101-1

MH101-1

MH101-1

MH101-1

MH401

B

MH401

A

" X

VAV-07

16"x16"

16"x10"

"x

" X

3HRFD

DUCT UP 45º

P U

E R

T O

R

I C

A

M Y

T

I O

N

L

G U

A R

D

R E

P A

IR

S

T O

B U

IL

D

IN

G

D

IN

IN

G F

A C

IL

IT

Y F

O R

T A

LL

E

N J

U A

N A

D

IA

Z

P U

E R

T

IC

O

MH101-1

N

H

VA

C S

U

PP

LY

A

IR

D

IS

TR

IB

U

TI

O

N

SPINNING FITTING W/ MANUAL

DAMPERS AND FLEXIBLE

DUCTS OF 8".

SPINNING FITTING W/ MANUAL

DAMPERS AND FLEXIBLE

DUCTS OF 8".

AS-BUILT SET

DATED: 31 May 2024

CD-1 12"Ø

AutoCAD SHX Text

SS.WH.

SS.DW.

DATED: 31 May 2024 MH101-2

H

VA

C R

ET

U

R N

A N

D E

XH

AU

ST

A

IR

D

IS

TR

IB

U

TI

O

N

AutoCAD SHX Text

EF-01

AutoCAD SHX Text

EF-02

AutoCAD SHX Text

EF-04

AutoCAD SHX Text

EF-03

AutoCAD SHX Text

STO.

AutoCAD SHX Text

EF-08

AutoCAD SHX Text

EF-07

AutoCAD SHX Text

SF-07

AutoCAD SHX Text 20" X 18"

AutoCAD SHX Text 12"x12" EA DUCT

AutoCAD SHX Text

UP TO

AutoCAD SHX Text

EF-06

AutoCAD SHX Text

AT

AutoCAD SHX Text

ROOF

AutoCAD SHX Text EG-1 14"x12"

AutoCAD SHX Text

600 CFM EA

AutoCAD SHX Text 12"x6"

AutoCAD SHX Text

RG-1 10"Ø

AutoCAD SHX Text

220 CFM RA

AutoCAD SHX Text 12"x6"

AutoCAD SHX Text 40"x16"

AutoCAD SHX Text

4344 CFM RA

AutoCAD SHX Text 36"x18"

AutoCAD SHX Text RG-2 14"x12"

AutoCAD SHX Text

504 CFM RA

AutoCAD SHX Text OAL-1 78"x12"

AutoCAD SHX Text

1,587 CFM OA

AutoCAD SHX Text

LRD-2

AutoCAD SHX Text 6 SLOTS 3/4" x 8'-0"

AutoCAD SHX Text

2,560 CFM RA

AutoCAD SHX Text

LRD-1

AutoCAD SHX Text 4 SLOTS 3/4" x 8'-0"

AutoCAD SHX Text

1,505 CFM RA

AutoCAD SHX Text 26"x10"

AutoCAD SHX Text 26"x10"

AutoCAD SHX Text 26"x10"

AutoCAD SHX Text 30"x18"

AutoCAD SHX Text

AHU-01

AutoCAD SHX Text

SF-08

AutoCAD SHX Text

LSD-3

AutoCAD SHX Text 8 SLOTS 1" x 10'-0"

AutoCAD SHX Text

3520 CFM SA

AutoCAD SHX Text

LSD-3

AutoCAD SHX Text 8 SLOTS 1" x 10'-0"

AutoCAD SHX Text

3520 CFM SA

AutoCAD SHX Text 18" X 16"

AutoCAD SHX Text 14" X 8"

AutoCAD SHX Text 28" X 26"

AutoCAD SHX Text

EG-3 18-3/4" X 13-3/4"

AutoCAD SHX Text

313 CFM EA

AutoCAD SHX Text

EG-3 18-3/4" X 13-3/4"

AutoCAD SHX Text

313 CFM EA

AutoCAD SHX Text

EG-3 18-3/4" X 13-3/4"

AutoCAD SHX Text

313 CFM EA

AutoCAD SHX Text

EG-3 18.75" X 13.75"

AutoCAD SHX Text

313 CFM EA

AutoCAD SHX Text

EAL-1

AutoCAD SHX Text

EAL-1

AutoCAD SHX Text

EAL-1

AutoCAD SHX Text

3HRFD

AutoCAD SHX Text

3HRFD

AutoCAD SHX Text

3HRFD

AutoCAD SHX Text

3HRFD

AutoCAD SHX Text

3HRFD

AutoCAD SHX Text

KH-01

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

3HRFD

AutoCAD SHX Text 34"x12"

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

ACCESS HATCH

AutoCAD SHX Text 18" X 16"

AutoCAD SHX Text

ACCESS HATCH

AutoCAD SHX Text

AutoCAD SHX Text

MH101-2

AutoCAD SHX Text

AutoCAD SHX Text

MH101-2

AutoCAD SHX Text

AutoCAD SHX Text

MH101-2

AutoCAD SHX Text

AutoCAD SHX Text

MH101-2

AutoCAD SHX Text

AutoCAD SHX Text

MH101-2

AutoCAD SHX Text

MH401

AutoCAD SHX Text B

AutoCAD SHX Text

MH401

AutoCAD SHX Text A

AutoCAD SHX Text DUCT WORK, CONNECTION AND RELOCATIO OF THE EXISTING HOOD WERE DELETED FROM THIS JOB

AutoCAD SHX Text DUCT WORK, DIFFUSER AND CONNECTION TO THE EXISTING HOOD WERE DELETED FROM THIS JOB

AutoCAD SHX Text

SS.WH.

AutoCAD SHX Text

SS.DW.

AutoCAD SHX Text

A. VARGAS

J. RUIZ

MH102

4034AS-BUILT SET

DATED: 31 May 2024

R O

O F

PL

AN

H

VA

C L

AY

O

U T

AutoCAD SHX Text

SERVICE

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

SERVICE

AutoCAD SHX Text

AREA

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

EF-06

AutoCAD SHX Text

NEW

AutoCAD SHX Text

EF-08

AutoCAD SHX Text

NEW

AutoCAD SHX Text

EF-07

AutoCAD SHX Text

NEW

AutoCAD SHX Text

SF-07

AutoCAD SHX Text

NEW

AutoCAD SHX Text

CU-01

AutoCAD SHX Text

OA

AutoCAD SHX Text

AutoCAD SHX Text

CFM

AutoCAD SHX Text

EA

AutoCAD SHX Text

SF-08

AutoCAD SHX Text

NEW

AutoCAD SHX Text

OA

AutoCAD SHX Text

AutoCAD SHX Text

CFM

AutoCAD SHX Text

EA

AutoCAD SHX Text

AutoCAD SHX Text

CFM

AutoCAD SHX Text

EA

AutoCAD SHX Text

AutoCAD SHX Text

CFM

AutoCAD SHX Text

SA

AutoCAD SHX Text

AutoCAD SHX Text

CFM

AutoCAD SHX Text

SA

AutoCAD SHX Text

REFRIGERANT LINES

AutoCAD SHX Text

DOWN TO AHU-01

AutoCAD SHX Text N

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

AutoCAD SHX Text

AS SHOWN

NEW FREEZER & REFRIGERATOR CONDENSING UNITS

MH401

H

VA

C D

U C

TW

O

R K

SE

C

TI

O

N

1-1/2" INSULATION

CEILING

CEILING

LAMPS

SUPPLY CEILING DIFFUSER1-1/2" INSULATION

SECTIONA

SECTIONB

ROOF OPENING TO

EXHAUST FAN AND SUPPLY FAN

1'-6"

1' -0

'-4

8"

2'-2"

2'-2"

'-5

8"

9' -3

8"

2' -0

2'-0"

1' -0

1'-2"

'-6

2"

'-0

2"

9' -9

2"

9' -0

AS-BUILT SET

DATED: 31 May 2024

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text

HAND WASH

AutoCAD SHX Text

HVAC DUCT

AutoCAD SHX Text

MH401

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text

SERVING AREA

AutoCAD SHX Text

HVAC DUCT

AutoCAD SHX Text

MH401

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

RECTANGULAR TO ROUND

TRANSITION

RECTANGULAR SUPPLY DUCT

UPSTREAM

STRAIGHT ROUND DUCT

4 DIA. (MIN. 2'-0")

FASTEN AND SEAL CONNECTION

VAV UNIT

CLINCH

CONNECTION

AI

R

F

LO

W

FASTEN AND SEAL

CONNECTION

ACOUSTICAL DUCT

LINING OR SOUND

ABSORBER AS

REQUIRED

MAIN

DUCT

NOTES:

1. THE OPERATION OF VARIABLE VOLUME TERMINAL UNITS ARE AFFECTED BY EXCESSIVE

TURBULENCE ON THE ENTERING SIDE OF EACH TERMINAL UNIT THEREFORE. TERMINAL

UNITS MUST NOT BE INSTALLED TOO CLOSE TO MAIN DUCTS, ELBOWS AND FITTINGS.

2. WHEN MINIMUM UPSTREAM STRAIGHT DUCT CONNECTION TO TERMINAL AS INDICATED

ABOVE CANNOT BE MAINTAINED, PROVIDE ORIFICE PLATE. STRAIGHTENING VANES OR

OTHER OTHER DEVICE AS RECOMMENDED BY TERMINAL UNT MANUFACTURER AND

SUBMIT TO ENGINEER FOR REVIEW PRIOR TO INSTALLATION.

3. MANUFACTURER OF TERMINAL UNIT SHALL PROVIDE CONTROLS ON LEFT OR RIGHT SIDE

AS REQUIRED BY FIELD CONDITIONS.

4. ARRANGE ACCESS TO PERMIT EASY FIELD BALANCE AND MAINTENANCE OF TERMINAL

UNIT

SCALE:

DETAIL9

NOT TO SCALE

VARIABLE AIR VOLUME

INSTALLATION

MH501

SMALL DOUBLE VANE

/11

UP TO 18"

AIR FLOW

1"R

"8 o90

2"R

AIR TURNED VANES

DOUBLE THICKNESS

SHEET METAL

90 ELBOW

DUCT

SHEET METAL

AIR FLOW

19" & 0VER

AIR FLOW

LARGE DOUBLE VANE

2 1/4"

4" R.

2" R.

o

DOUBLE THICKNESS

AIR FLOW

AIR TURNED VANES

SHEET METAL

DUCT

SHEET METAL

90 ELBOW

MAIN DUCT

LOCKING COLLAR

SPLITTER ROD

DAMPER

SPLITTER

AIR

FLOW

BRANCH DUCT

SECURE SAFING TO DUCT

CEILING

DIFFUSER

6"MIN.

FLOW

AIR

45°

"M

IN

IM

U M

6"M

IN 45°

OPPOSITE

BLADES DAMPER

SUPPLY AIR DUCT ACOUSTIC

LINED OR INSULATED AS

SCHEDULED

OPPOSED BLADE DAMPER,

INSTALL AS PER DIFFUSER

MANUFACTURER'S

RECOMMENDATIONS

DUCT DROP ACOUSTIC LINED

OR INSULATED AS

SCHEDULED

DUCT SEALANT

ALL AROUND

MAIN DUCT - ACOUSTIC

LINED OR INSULATED AS

SCHEDULED DOUBLE THICKNESS

VANES

POURED

CONCRETE OR

CMU WALL

RECTANGULAR

OR ROUND

DUCTWORK

SHEETMETAL SAFING ALL

AROUND (MIN 22 GA) TO

MATCH DUCTWORK

MATERIAL

DUCT EXTERIOR

INSULATION

NOTE: INTERIOR WALLS

REQUIRE SAFING ON ONE

SIDE ONLY ON CONCEALED

DUCTS AND ON BOTH SIDES

OF WALL ON EXPOSED

DUCTS

SHEETMETAL

DUCT

45 DEGREE ENTRY Ø = 45°

AT CORNERS

CLOSE OPENING

L=1/4" W, 4" MIN.

Ø

L

W

SCALE:

DETAIL1

NOT TO SCALE

CEILING DIFFUSER

MH501 SCALE:

DETAIL2

NOT TO SCALE

TYPICAL DAMPER

MH501 SCALE:

DETAIL3

NOT TO SCALE

SPLITTER DAMPER

MH501

SCALE:

DETAIL7

NOT TO SCALE

DUST PENETRATION NON-RATED WALLS

MH501

SCALE:

DETAIL12

NOT TO SCALE

BRANCH CONNECTION

MH501

VA

R

IE

S

C O

O R

D . I

N F

IE

LD

ANGLE SUPPORT

CONCRETE SLABEXPANSION

SELF-DRILLING

3/8" Ø

ALL THREADED ROD

SCALE:

DETAIL6

NOT TO SCALE

DUCTWORK SUPPORT

MH501

SI

ZE

V

AR

IE

S

(S

EE

D W

G S)

M

IN

2'

-0

SIZE VARIES

(SEE DWGS)

GALVANIZED

STEEL DUCT

(SEE SPECS)

BELLMOUTH

CONNECTION

WITH DAMPER

GYB.

FLEX DUCT CONN.

WITH METAL CLAMPS

HIGH CAPACITY

HEPA DIFFUSER

ACOUSTIC OR

GYP. CEILING

(SEE SPECS)

1-1/2" INSULATION

(SEE SPECS.)

SIZE VARIES

(SEE DWGS)

(S

EE

D W

G S)

SI

ZE

V

AR

IE

S

BELLMOUTH

CONNECTION WITH

DAMPER GYB.

FLEX DUCT CONN. WITH

METAL CLAMPS (THERMAFLEX

M-KC OR APPROVED EQUAL)

ACOUSTIC OR

GYP. CEILING (SEE

SPECS)

HIGH CAPACITY

ULPA DIFFUSER

1-1/2" INSULATION

(SEE SPECS.)

GALVANIZED

STEEL DUCT (SEE

SPECS)

SCALE:

DETAIL8

NOT TO SCALE

DIFFUSER FLEXIBLE CONNECTION

MH501

ISAT "ABHW" SEISMIC

BRACKET, ICBO #PFC 5566

OR APPROVED EQUAL.

THREADED ROD

SINGLE CHANNEL

TRAPEZE SUPPORT.

SINGLE CHANNEL DUCT

TOP REINFORCEMENT.

#10 SHEET METAL

SCREWS MAX. 12"O.C.

45°MAX.

ISAT "RCHW" SEISMIC

OR APPROVED EQUAL.

BRACKET, ICBO #PFC 5566

THREADED ROD

SECTION THRU HVAC DUCT

CONCRETE SLAB

EXPANSION

SELF-DRILLING

SCALE:

DETAIL4

NOT TO SCALE

ELBOW CONSTRUCTION

MH501

SCALE:

DETAIL10

NOT TO SCALE

TYPICAL DUCT SEISMIC RESTRAINT

2-WAY TRANSVERSE RIGID BRACING

MH501

"M

IN

.PREFABRICATED CURB AND

COUNTERFLASHING BY HVAC

CONTRACTOR

FLASHING BY G.C.

DUCTWORK - SEE PLAN

BACKDRAFT DAMPER

EXHAUST FAN

ROOF LEVEL

CONCRETE SLAB

SCALE:

DETAIL11

NOT TO SCALE

ROOF EXHAUST FAN INSTALLATION

MH501

AHU

TSP 1"

W

IT

H E

Q U

IP

M

EN

T

C O

O R

D . O

N F

IE

LD

MIN=FAN

2" DIA. PVC PIPE

SLOPE

6" DIA. FUNNEL

FINISH FLOOR

AHU CONDENSATE

ACCESS DRAIN FOR

FITTING CONNECTION

COORD. WITH EQUIPMENT

SCALE:

DETAIL5

NOT TO SCALE

CONDENSATE "P" TRAP AND

FUNNEL INSTALLATION

MH501

ELEVATION

CONCRETE SLAB

EXPANSION

SELF-DRILLING

BLADE LOCK

FUSIBLE LINK

FIRE RATED FLOOR

VERTICAL

WELD FIRE

DAMPER FRAME

TO SLEEVE

1 1/2" X 1 1/2" 1/8" ANGLE

IRON ALL AROUND DUCT,

WELD TO SLEEVE &

INSTALL TIGHT TO WALL

CONSTRUCTION.

BREAKAWAY TYPE

SLIP JOINT DUCT

CONNECTION

STAINLESS STEEL

NEGATOR CLOSURE

SPRING.

PACK VOID WITH 1/4"

MIN. TO 1/2" MAX.

NON-ASBESTOS

TYPE CAULKING.

#1Ø GAUGE BLACK

IRON SLEEVE ALL

AROUND

SCALE:

DETAIL13

NOT TO SCALE

FIRE DAMPER 3HR RATED

MH501

MH501

H

VA

C D

ET

AI

LS

AS-BUILT SET

DATED: 31 May 2024

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

H

VA

C S

C H

ED

U

LE

S

D I R E C T E X P A N S I O N A I R H A N D L I N G U N I T S C H E D U L E

A I R S I D E

C O O L I N G C O I L

ENTERING LEAVING P.D.

INCH

WB.°FDB.°FWB.°FDB.°F

F/A

CFM

RETURN

CFMCFM

TOTAL

TYPEAREA SERVEDUNIT No.

TYPE (IN.

T.S.P.

W.G.)

PH.

VOLTSR.P.M.HP.

MOTOR

LOCATION

MOTOR

HZ.

F A N O P T I O N A L E Q U I P.

MIXING

BOX BOX

FILTER COMB.

F/M BOX

PRE

FILTER

EFF.

FINAL

FILTER

EFF.

SIMILAR TO REMARKS

TOTAL

CAPACITY

(MBH)

SENS.

CAPACITY

(MBH)

COIL

TYPE

FACE

AREA

EVAP.

TEMP.°F

ROWS

FPF

C O I L

W.G.

DESIGNATION TYPE FACE SIZEC F M REMARKSFINISH SIMILAR TO

AIR TERMINAL SCHEDULE

UNIT No. AREA SERVED TYPE FUNCTION CFM RPM.

TIP

SPEED

F.P.M.

S.P.

INCH

DRIVE SONES

HP R.P.M. VOLTS TYPEPH

HZ.

M O T O R

ACCESORIES SIMILAR TO REMARKS

F A N A N D V E N T I L A T O R S C H E D U L E

CLASS

PRESS

DUCTWORK CONSTRUCTION SCHEDULE

DC-DISCHARGE

AHU-SUPPLY/RETURN

DUCT SECTION

DC-SUCTION

GENERAL EXHAUST

TRANSVERSE

MATERIAL

CONSTRUCTION

CLASS

SEAL

CLASS CL

LEAKAGE

TEST

LEAK

JOINTS REMARKS

+4/-4

-22

+22

GALV. STEEL

GALV. STEEL

GALV. STEEL

-2 GALV. STEEL A

A

A

A

YES

YES

YES

YES

DUCTMATE OR

TDC

DUCTMATE OR

TDC

WELDED

WELDED

BASIS OF DESING-MANUFACTURER'S DATAMAXIMUM

SERVING

VARIABLE VOLUME BOX SCHEDULE

REMARK'S

MARK

IDENTIFICATION

CFM BOX

SIZE INLET (IN) NOISE CRITERIA BASIS

AIR RADIATED

CONTROL

VALVE

2 WAYOUTLET (IN)RM. #

P.D.

(IN.WG)

AT.MAX.CFM

SIMILAR TO

TEMP.°F

SUCTION

HZ.

PH.

COMPRESSORS WATER COOLED CONDENSERCONDENSER-FANS

AIR COOLED

TEMP.°F

SUCTION VOLTS.KW.CAPACITYQTY

SERVICEUNIT No.

HP.

MOTOR VOLTS.QTY HZ.

PH.

FACTOR

FOULING

FT. WG.

P.D.

TEMP.°F

COND. EWT.°F LWT,°F GPM

SIMILAR TO REMARKS

CONDENSING UNIT SCHEDULE

VAV-01 01,04 1910 PRICE SDV5

VAV-02 02 1680

VAV-03

VAV-04

VAV-05

VAV-06

VAV-07

09,11,18

16" X 15" 21

.54

.55

.64

.54

.21

.22

.35

AHU-01 BLDG.#148 AHU-01 10660 5760 - 82 73.5 54.97 54.83 .77 669.21 315.05 - 24.41 6

14 - 2.54 8.2 10 1800 208 - - - - CARRIER- 28ME ANTI CORROSION TREATMENT

CU-01 AHU-01 1 674.8 45 59.60 208 3

60 - 4 - 208 3

N/A N/A N/A N/A N/A N/A CARRIER 38APD

.016 - .095 METALAIRE 5750 SERIES 4- WAY CEILING DIFFUSERCD-1 395-470

.025-034 METALAIRE 4- WAY CEILING DIFFUSERCD-2

.080 METALAIRELRD-2

.037 METALAIRE CC5-1 -RG-1

.037 CC5-1 -RG-2 METALAIRE

275-325

320CFMFT

327-392

554-665

CONSTRUCTION

ALUMINUM

MATERIAL

ALUMINUM

ALUMINUM

ALUMINUM

ALUMINUM

P.D.

IN W.G

24" X 24"

24" X 24"

13" X 13"

17" X 15"

DAMPER

WHITE OBD

EF-01

EF-02

EF-03

EF-04

EF-06

EF-07

MEN BATHROOM

WOMEN BATHROOM

RESTROOM

STORAGE

SCULLERY

SERVING AREA

CEILING BLOWER EXHAUST 313

.75

1.5

13.4

.33

SF-07 SERVING AREA 1920 1269 3322 1.5 - 24 1.5 1725 208 3

EXHAUST

EXHAUST

EXHAUST

EXHAUST

EXHAUST

SUPPLY

CENTRIFUGAL

ROOF

CENTRIFUGAL

ROOF ODP-SE

ODP-PE

ODP-PE

ROOF CURB COOK ACRU-B

VCR-XP

ROOF CURB KSP-B

COOK

COOK

.50

.50

5.5

5.5

.15 115 -

- COOK

COOK GEMINI 200-700 SERIES

CEILING BLOWER 115 1

ANTI CORROSION TREATMENT,

HURRICANE RATED.

RIGHT

SIDE

BHP

FORWARD

CURVED

PRICE SDV5

PRICE SDV5

PRICE SDV5

PRICE SDV5

PRICE SDV5

PRICE SDV5

14" X 12-1/2"

24" X 18"

12" X 8"

12" X 10"

12" X 10"

16" X 15"

22 5 1725 208 3 60 ODP-PE ROOF CURB VCR-HPCOOKEF-08 FOO PREP 8800 958 7524 1.5 -EXHAUSTCENTRIFUGAL

ROOF

KITCHEN SUPPLY

PACKAGED

SF-08 FOOD PREP 7040 793 4152 1.5 - 31 5 1725 208 3

SUPPLY ODP-PE ROOF CURB KSP-BCOOKKITCHEN SUPPLY

PACKAGED

ALUMINUM WALL CAP

WCA-2

ALUMINUM WALL CAP

WCA-2

GEMINI 200-700 SERIES

NECK SIZE

12"Ø

10"Ø WHITE

WHITE

WHITE

WHITE

OBD

5750 SERIES

.037 COOK SG-12 FRAME AT A 40 DEGREE ANGLEEG-1

.500 SG-12 FRAME AT A 40 DEGREE ANGLEEG-2 COOK

SEE IN DWGS

SEE IN DWGS

ALUMINUM

ALUMINUM

17" X 15"

13-1/2" x 13-1/2" 12" X 12"

WHITE

WHITE

6675R SERIES

METALAIRECD-3 ALUMINUM WHITE OBD24" X 24" 10"Ø 5750 SERIES

METALAIRECD-4 ALUMINUM WHITE OBD24" X 24" 10"Ø 5750 SERIES

.129 METALAIRELSD-1 140 CFMFT ALUMINUM WHITE OBDSEE IN DWGS SEE IN DWGS 6675 SERIES

.129 METALAIRELSD-2 210 CFMFT ALUMINUM WHITE OBD 6675 SERIES

.080 METALAIRELRD-1 200 CFMFT ALUMINUM WHITE - 6675R SERIES

275-325 .025-034

275-325 .025-034

FUNCTION

SUPPLY

SUPPLY

SUPPLY

SUPPLY

SUPPLY

SUPPLY LINEAR

DIFFUSER

LINEAR

DIFFUSER

SEE IN DWGS SEE IN DWGS

4 SLOT 3/4"

6 SLOT 3/4"

RETURN

RETURN

LINEAR

DIFFUSER

LINEAR

DIFFUSER

SEE IN DWGS SEE IN DWGS

SEE IN DWGS SEE IN DWGS

RETURN RETURN

GRILL

RETURN RETURN

GRILL

CEILING

DIFFUSER

2- WAY CEILING DIFFUSER

3- WAY CEILING DIFFUSER

CEILING

DIFFUSER

CEILING

DIFFUSER

CEILING

DIFFUSER

4 SLOT 3/4"

6 SLOT 3/4"

10" X 10"

14" X 12"

EXHAUST

EXHAUST

EXHAUST

GRILL

EXHAUST

GRILL

14" X 12"

EXHAUST EXHAUST

GRILL

SEE IN DWGS 18-3/4" x 13-3/4" 16-3/8"X11-3/8" .500 ALUMINUM WHITE

COOK GEMINI ALUMINUM

GRILLEEG-3 -

.08 METALAIRELRD-3 560CFMFT ALUMINUM WHITE - 6610R SERIESRETURN LINEAR

DIFFUSER SEE IN DWGS SEE IN DWGS 8 SLOT 1"

ROOF CURB

MH601

INTAKE OUT SIDE

AIR

SEE IN DWGS SEE IN DWGS SEE IN DWGS .20 ALUMINUM MILL - RUSKIN EME420MDOAL-1 HIRRICANE RATED, ANTI CORROSION TREATMENT, BIRDSCREEN

.037 CC5-1 -RG-3 METALAIRE3840-4800 ALUMINUM49-3/4" X 31-3/4" WHITE -RETURN RETURN

GRILL

ALUMINUM

48" X 30"48" X 30"

CEILING BLOWER

CEILING BLOWER

313 1600 2644 60.50 - 5.5 - COOK115 1 ALUMINUM WALL CAP

WCA-2

GEMINI 200-700 SERIES

313 1600 2644 60.50 - 5.5 - COOK115 1 ALUMINUM WALL CAP

WCA-2

GEMINI 200-700 SERIES

.15

.15

.15

.129 METALAIRELSD-3 360 CFMFT ALUMINUM WHITE OBD 6675 SERIESSUPPLY LINEAR

DIFFUSER SEE IN DWGS SEE IN DWGS 8 SLOT 1"

EAL-1

EXHAUST AIR LOUVER

EXHAUST LOUVER 18" X 18".

GRAVITY EXHAUST COMBINATION.

LOUVER DAMPER 6" EXTRUDED.

ALUMINUM DRAINABLE.

ALUMINUM BLADES5

8" X .040".

ALUMINUM SCREEN.

ALUMINUM BACKDRAFT DAMPER COMBINED IN

COMMON FRAME.

45 % FREE AREA.

FINISH TO BE SELECTED BYARCHITECT.

SIMILAR TO RUSKIN - ELBD375E

REMARKS:

1. EXHAUST AND MAKE UP AIR FANS SHALL BE

CONTROLLED WITH THE LIGHT SWITCH OF THE

KITCHEN HOOD THEY SERVE. PROVIDE REQUIRED

ELECTRICAL CONNECTIONS.

2. ANTI CORROSION TREATMENT.

3. HURRICANE RATED.

4. BIRDSCREEN.

1,2

1,2

1,2

1,2

2,3,4

2,3

2,3

2,3

2,3

AS-BUILT SET

DATED: 31 May 2024

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BACnet MS/TP

SITE NETWORK

ARCHITECTURE

BUILDING MANAGEMENT SYSTEM

EC-B0S-8

CONTROLLER / SERVER

MEMORY EXPANSION MEMORY

WEB USER INTERFACE ADD-ON

DUAL PORT RS-485

POWER MODULE

DRIVER FOR MS/TP BACnet

EC-BOS-6 W/

EC-NPM-256

EC-NPB-2X-485

EC-WPM-US

EC-DIR-MSTP

EC-UI-SAX

MOUSE

WORK STATION

KEYBOARD

MONITOR

ETHERNET

TABLETSMART PHONE

EXHAUST FANS 01,02,03,04,05,06,07,08

D

IS

TE

C

H C

O N

TR

O

LS

AHU-1

EC

B

-X X

AHU-1

BACnetECB-VAVS

CONTROLS

DISTECH

DISTECH

CONTROLS CONTROLS

DISTECH

DISTECH

CONTROLS

ECB-VAVS BACnet

AHU-1 AHU-1

BACnetECB-VAVS

CONTROLS

DISTECH

DISTECH

CONTROLSCONTROLS

DISTECH

DISTECH

CONTROLS

ECB-VAVS BACnet

AHU-1 AHU-1

BACnetECB-VAVS

CONTROLS

DISTECH

DISTECH

CONTROLS

AHU-1

BACnetECB-VAVS

CONTROLS

DISTECH

DISTECH

CONTROLSCONTROLS

DISTECH

DISTECH

CONTROLS

ECB-VAVS BACnet

AHU-1

VAV-05 VAV-06 VAV-07VAV-03 VAV-04VAV-02VAV-01

D

IS

TE

C

H C

O N

TR

O

LS

EC

B

-X X

COMMUNICATION WIRES

FROM PREVIOUS BACnet VAV DDC CONTROLLER

ROOM TEMPERATURE SENSOR

COMMUNICATION WIRES

TO NEXT BACnet VAV DDC CONTROLLER

DISTECH-CONTROLS ; MODEL: ECB-VAVS

BACnet VAV CONTROLLER

VELOCITY PROBE

MODEL: EC-VUE

DISTECH-CONTROLS

CONTROL TRANSFORMER

120 VAC / 24VAC

DISTECH-CONTROLS

CONTRACTOR

120 VAC BY ELECTRICAL

GROUND

NEUTRAL

LINE

VAV DDC CONTROLLER CONTROL DIAGRAM

TYPICAL FOR ROOM TEMPERATURE CONTROL APPLICATION

NOTE: INTERLOCK WITH

AHU'S SCHEDULE

SATUSDI

M

CONTACTOR

120 Vac

EXHAUST FANS CONTROLS SCHEMATIC

CS-01 CURRENT SWITCHES ACIA/MCS

SIMILAR TODESCRIPTIONDESIGNATION

BILL OF MATERIAL

BC-1 BACnet CONTROLLER ECB-XXX DISTECH-CONTROLS

BC-XX

DISTECH CONTROLS

CONTROL

TRANSFORMER

TERMINALSBREAKER

CIRCUIT

FANS 1,2 & 3 LOCAL CONTROL PANEL

START/STOPDO

EXHAUST FANS 01,02,03,04,05,06,07,08

H O A

SUPPLY FANS 07,08

SIMILAR TO:

SUPPLY FANS 07,08

SIMILAR TO:

SIMILAR TO:

MH602

H

VA

C C

O N

TR

O

LS

AS-BUILT SET

DATED: 31 May 2024

NOTE:

EF-06 WILL BE THE ONLY FAN TO BE

CONTROLLED BY THE HVAC CONTROL SYSTEM

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

AI

DTS-02

COIL

AI

DI

DO

AO

BC-XX

AIR HANDLING UNITS 01 CONTROL DIAGRAM

120 VAC

TO FIRE ALARM

SD-01

DI

FROM UNITS EQUIPMENT

INPUTS AND OUTPUTS

AI

LH

DPT-01 DTS-01

AI

D

SPEED CONTROL

STATUS

AO

DI

VFD

M

DO START/STOP

X

AIR

OUTSIDE

FILTERS

RETURN

AIR

DTS-03AI

COOLING

SYSTEM

BC-XX

DISTECH CONTROLS

CONTROL

TRANSFORMER

TERMINALSBREAKER

CIRCUIT

AHU-1 & 3 LOCAL CONTROL PANEL

2 SD-01 DUCT SMOKE DETECTOR SYSTEM SENSORD4120

2 CO2-01 & 02 CARBON DIOXIDE SENSORS KELEKCD

BAPIDTS-031

2 DTS-01 & 02 DUCT TEMPERATURE SENSORS- 12 INCHES BAPIBA/10K3-D12-WP

BILL OF MATERIAL

DUCT TEMPERATURE SENSORS- 8 INCHES BA/10K3-D8WP

BELIMONMX24-SRMODULATING DAMPER ACTUATORDA-01, 02 & 032

SUPPLY

AIR

AI CO2-02

AI CO2-01

AO

AO

616 DWYERDIFFERENTIAL PRESSURE TRANSMITTERDPT-01 & 022

1 BC-1 BACnet CONTROLLER- 12UI/12UO ECB-300 DISTECH-CONTROLS

TO CONDENSING UNIT

L

DPT-02

AI

H

DA

DA

1 VFD-01

1 VFD-03

SD-01

DI

TO FIRE ALARM

SYSTEM

AHU

1. THE BMS SHOULD START / STOP THE UNIT BASE ON A DAILY

SCHEDULE.

2. CONTROL BMS WILL MONITOR SUPPLY, RETURN AND MIX

TEMPERATURE SENSORS. A CARBON DIOXIDE SENSORS

FOR OUTSIDE AND RETURN AIR, STATIC PRESSURE

SENSOR, SMOKE DETECTOR, FILTER AND FAN STATUS.

3. VARIABLE FREQUENCY DRIVE WILL INCREASE OR

DECREASE HZ IN ORDER TO REACH DESIRE STATIC

PRESSURE SETPOINT. THE VFD WILL DECREASE UNTIL A

SPECIFIC HERTZ THAT WILL BE DETERMINE BY BALANCE

CONTRACTOR.

4. A SMOKE DETECTOR INSTALLED AT THE SUPPLY DUCT WILL

SHUTDOWN THE UNIT IN CASE OF ACTIVATION.

5. A SUPPLY TEMPERATURE SENSOR WILL MONITOR THE UNIT

TO ASSURE 55 °F.

6. CARBON DIOXIDE SENSOR INSTALLED AT THE RETURN

DUCT WILL MONITOR PPM AND COMPARE IT WITH OUTSIDE

CARBON DIOXIDE PPM. IF THE CO2 SENSOR FROM THE

RETURN IS HIGHER THAN 1,000 PPM AND 250 PPM FROM

OUTSIDE CO2 A CONTROL DAMPER AT THE FRESH AIR WILL

MODULATE TO OPEN AN A CONTROL DAMPER AT THE

RETURN WILL MODULATE TO CLOSE.

7. A DIFFERENTIAL PRESSURE TRANSMITTER WILL BE

INSTALLED TO MONITOR FILTER CONDITION.

EXHAUST FANS

1. THE BMS WILL START THE FANS EVERY TIME THE SYSTEM DETECT AN

AIR HANDLING UNIT RUN STATUS.

2. FANS WILL STOP WHEN THE BMS IDENTIFY THAT ALL UNITS HAS A

STOP STATUS.

3. CONTROL BMS WILL MONITOR FANS STATUS.

4. KITCHEN EXHAUST & SUPPLY FANS WILL BE CONTROL BYLOCAL

SWITCH @ KITCHEN HOOD .

VAV'S

1. CONTROLS VAV'S WILL BE INDIVIDUALLY PROGRAMMED BASED ON

THE DESIGN AIR FLOW (CFM)

2. A ZONE SENSOR WILL MONITOR ROOM TEMPERATURE AND MODULATE

THE BOX TO ASSURE THE 72 °F

3. CONTROL BMS WILL MONITOR BOX POSITION, CFM, MAX AND MIN.,

TEMPERATURE AND SETPOINT.

SEQUENCE OF OPERATION:

VARIABLE FREQUENCY DRIVE 7.5 HP 480/60/3

FOR AHU-1

VARIABLE FREQUENCY DRIVE 1 HP 208/3/60

FOR AHU-3

208 V FOR AHU-1

MH603

H

VA

C C

O N

TR

O

LS

AS-BUILT SET

DATED: 29 May 2024

QTY DESIGNATION DESCRIPTION SIMILAR TO

AutoCAD SHX Text

A. VARGAS

AutoCAD SHX Text

J. RUIZ

AutoCAD SHX Text 2020-01-14

FI

E

AL

AR

M

F

LO

O R

P

LA

N

LOBBY

WOMEN

RESTROOM

MEN

RESTROOM

MECH. ROOM

EXISTING FOOD PREP.

STO. REST.

WALK IN FREEZER

WALK IN COOLER

SCULLERY

MECH.

ROOM FOOD STORAGE

STORAGE

ELECTRICAL

ROOM

DINING AREA

ENTRANCE

WATER

HEATER/

SOFTENER

SERVICE

ENTRANCE

HAND WASH AREA

OFFICE

AREASERVING AREA

OFFICERS

DINING AREA

HALLWAY

FIRE ALARM FLOOR PLAN

LEGEND:

AS-BUILT SET

DATED: 31 May 2024 �� ��

F��

AutoCAD SHX Text 2020-01-14

Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model
Sheets and Views
Model

File details come from the government source that posted it. Updated .