Attach__No__1B_-_Rpt_PWQTRP_HJ0083.pdf
PDF 443 KB Posted
- Attached to
- Environmental Services Contract Federal contract opportunity
- Solicitation number
- 140D0422R0077
View the file
Other files for this federal contract opportunity
Show all 50
Environmental Services Contract has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Process Waste Questionaire Technical Response Package (PWQTRP)
Waste Process Code: HJ0083 Page 1 of 3
Information Submitted By Waste Generator for PWQ#
Generator Tracking#: 22-068-003 Generator PWQ Name: Expired 03GY330CAT Curing Colution Co
Priority Routine
GeneratorComments:
Environmental Coordinator: Michael Mau
Created By: Rebecca Fafard
Udated By
Recertified By:
Generation Quantity: 1.00 Quarter
Generation Process: Expired 03GY330CAT Curing Colution Component by PPG Aerospace
Per
Chemical Physical Characteristics:
Solid: Sludge:
Gas: Aerosol: No PCB Concentration: N/A
Layers (liquids only): Single Phase
Is waste generated from cleanup, or from dilution of PCBs with an original concentration of 50 ppm or greater? No
Liquid: 100.00%
If yes, original concentration: (ppm)
Color: Odor Description: FlashPoint (if liquid): 136
SpecificGravity (if Liquid): Viscosity(of liquid): Med
PH if aqueous): N/A Is material pumpable? No
Is material explosive? No
Does material react violently with water or create toxic or flammable vapors when in contact with water? No
Does waste contain halogens? No
Does waste contain over 50% debris (manufactured object, plant or animal matter, or natural geological material) exceeding 60 mm partical size? No Does waste contain asbestos? No
Does waste contain medical sharps or infection material (biomedical waste)? No
Pints
Waste Process Code: HJ0083 Page 2 of 3
WASTE COMPOSITION
TCLP TOXICITY CHARACTERISTICS
HAZARD DETERMINATION: Regulated as a hazardous waste
OTHER REGULATORY DETERMINATION: None
SAMPLING AND ANALYSIS REQUIREMENT:
THE WASTE EVALUATION IS BASED UPON THE ABOVE WASTE DESCRIPTION. IF THE GENERATOR
CANNOT VERIFY THAT THE WASTE MATCHES THIS DESCRIPTION, ANALYSES SHOULD BE CONDUCTED FOR THE FOLLOWING PARAMETERS: FLASH POINT, TCLP METALS AND ORGANICS LESS PESTICIDES, UHC METALS
PACKAGING:
1. 5 GAL. CONTAINER - UN1A2/Y1.4/100 (MINIMUM PERFORMANCE STANDARDS OR BETTER) 2.
30/14 GAL. CONTAINER - UN1H2/Y1.4/100 (MINIMUM PERFORMANCE STANDARDS OR BETTER) 3. 55
GAL. CONTAINER - UN1A2/Y1.4/140 (MINIMUM PERFORMANCE STANDARDS OR BETTER)
Constituent Lower % Upper %
Hexamethylene diisocyant 50 75 ethyl 3-ethoxypropionate 10 20 n-butyl acetate 1 5 solvent naphtha 1 5
1,2,4-trimethylbenzene 1.4 hexamethylene di-isocyana 1
Waste Process Code: HJ0083 Page 3 of 3
DOT MARKING LABEL: Hazardous Waste (WM8)
DOT PRIMARY HAZARD: Flammable Liquid, 3 (HMSL6S)
DOT SUBSIDIARY HAZARD #1 Not Required
DOT SUBSIDIARY HAZARD #2 Not Required
DOT ADDITIONAL LABEL #1 Not Required
DOT ADDITIONAL LABEL #2
DOT PSN and UN/NA#: UN1263, Waste paint, RQ (D006, D007)
EPA Codes
Comments
GENERATOR SHOULD PLACE SMALL CONTAINERS DIRECTLY INTO A DRUM. DO NOT POUR CONTENTS OF SMALL
CONTAINERS INTO DRUM.
Date PWQ/TRP Published: 3/9/2022Mike HodgesPWQ evaluated By:
Container Marking Requirements
Date TRP Modified: 1/6/2017 10:41:19 AM
WPC2 EPA
HJ0083 D001
HJ0083 D005
HJ0083 D006
HJ0083 D007
HJ0083 D008
HJ0083 D018
HJ0083 D019
HJ0083 D035
File details come from the government source that posted it. Updated .