This Statement of Work (SOW) outlines requirements for a Fire Station Alerting System at Fairchild Air Force Base, covering two geographically separated fire stations (Building 3 - Main Fire Station and Building 1314 - Station 2). The contractor must design, build, and install a complete alerting system that includes station control units, public address systems, speakers, amplifiers, LED lighting, and mobile device capabilities.

The system requirements include: 240W amplifiers with 6 inputs each, 60 ceiling speakers, 8 exterior horn speakers, 3 high bay speakers, 5 wall mounted box speakers, phone line crash detection, digital voice dispatching capabilities, door control for 14 doors, FirstNet cellular backup, integration with CAD systems, and a mobile app with mapping and turn-by-turn navigation. The work must be completed within 300 days after contract award, with normal hours of operation being 0700-1630 Monday through Friday. The contractor must provide 8 hours of training over 2 days for approximately 10 attendees per session. Security requirements include personnel background checks and escorted access on the installation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

FOR

Fire Station Alerting System

January 2025

FA462025QA921 - Fire Station Alerting System Attach. 1 - Statement of Work (SOW)

Statement of Work (SOW) For

Fire Station Alerting System

Fairchild AFB, WA

1. BACKGROUND: Fairchild AFB Fire and Emergency Services (FAFB FES) requires an updated fire station alerting system to replace existing systems that are end-of-life. Replacement System shall cover 2 geographically separated fire stations.

2. SCOPE OF WORK: The contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and non-personal services necessary to design, build, & install a fire station alerting system as described below. Contractor shall field verify items outlined in 4.1 are sufficient to meet the requirements of the contract. The contractor shall perform to the standards in this contract

3. OBJECTIVES: The contractor will provide a full station alerting system at B3 (Main Fire Station) and B1314 (Station 2) on Fairchild Air Force Base.

4. REQUIREMENTS:

Provide all equipment Meet all work stated in this Statement of Work Meet timelines stated in this Statement of Work Must remove and dispose of all old equipment off site Validate the system performance after installation Provide a minimum 8 hours of training over a 2-day period (4 hours each day) after system initialization while installation technician is on site.

Provide standard commercial warranty for repair and replacement of system components

4.1 NEW STATION ALERTING SYSTEM REQUIREMENTS:

Provide all necessary supplies to include wiring.

Provide any network switches, routers, or server racks required for system to operate Provide Station Public Address System for B3 and B1314. System must be configurable to allow for shutting off zones at night. System shall provide intelligible voice communication throughout 100% of both facilities and exterior within 25 feet.

Provide Qty (2) 240W Amplifiers (1 per station) capable of a minimum of 6 inputs each. Inputs consist of radios and telephone interfaces

Provide Qty (60) round ceiling speakers. B3 (Qty 49) and B 1314 (Qty 11) Provide Qty (8) exterior horn type speakers. B3 (Qty 5) and B 1314 (Qty 3).

Provide Qty (3) high bay speakers (B3) Provide Qty (5) wall mounted box speakers B3.

Provide for both stations a phone detector that detects the Crash Line ringing and projects the audio Provide Qty (2) station control units capable of digital voice dispatching and text to speech readout of job information. System must be configurable with ramping sound level tones Must be capable of transmitting digital voice dispatch across radio talk-group via donor Motorola

APX 7500 consolette radio.

Must have the ability to control station LED lighting and doors. B3 (12 Doors) and B1314 (2 doors)

Must have ability to show response information on station monitors B3 (Qty 2) and B1314 (Qty

1) to include countdown timers, maps, and emergency data.

Provide quantity of 6 – commercial off-the-shelf 6-foot 120v powered multi-colored LED Light Strips with wireless connectivity to station alerting control system. Qty (5) for B3 and Qty (1) for B1314

Provide quantity of 70 – recessed color changing LED lights to include required equipment for connecting to the station alerting control system. Qty (55) for B3 and Qty (15) for B1314

Provide comprehensive mobile device app that includes mapping, turn-by-turn navigation, incident information, and internal messaging.

Mobile device app must be adaptable so that each firefighter is only alerted when on duty and for the apparatus the firefighter is riding on that day.

System must be capable of FirstNet compatible cellular backup connectivity System must be able to accommodate 5 different emergency incident types LED lighting must be capable of 5 different colors and display a different color based on the emergency type.

Must have ability to integrate hydrant location data, as well as installation map layers into to mapping.

All components must be supported with an Uninterruptible Power Supply Must have redundant encrypted data transfer Must provide configurable Inputs/Outputs to open and close 14 garage doors, 2 building doors and a parking lot gate. (All wiring from doors/gate to the input/output device will be provided by government.)

Any remote access to unit from internet should be initiated through physical access from unit.

Must provide method of alert verification by dispatcher.

Must provide ability for dispatcher to initiate alerts through web-based system.

Must have the ability to integrate and receive response information from external CAD systems Contractor shall provide a minimum of 8-hrs of system training over a 2-day period (4 hours each day). Each training session will consist of approximately 10 attendees. The contractor shall provide training to include but not limited to basic system operation, set-up, system capabilities, and system configuration of all functions.

5. PARTS LIST:

Part Number Item Quantity General Purpose Input/Output (GPIO) Bay Door Controls 4 Station Control Unit (Text to speech, Heart smart ramping tones, color changing lights 2

12 U Server rack 2 GPIO Day/Night mode, Turnout Timer Control 2 Turnout timer 3 Station Board 2

LED Strip Light 6

Recessed Light 70

Uninterruptible Power Supply 2

240W Amplifier 2

Round Ceiling Speakers 60

Horn Speaker 8

Bay Speakers 3 Box Speakers 5

Radio Control Unit 1

6. GOVERNMENT FURNISHED EQUIPMENT AND SERVICES: The government shall furnish site access and electrical power. In the event of an emergency, dial 911.

7. SECURITY REQUIREMENTS: All personnel employed by the Contractor in the performance of this contract, or any representative of the Contractor entering the government installation, shall abide by all Fairchild Air Force Base security regulations. Personnel performing the work requested will be escorted for the duration on the installation. Individuals must be able to pass a background check that will be conducted prior to entry of the installation. Individuals performing the work will be required to provide their full name, DOB, SSN, driver’s license issuing state and license number to gain access to the installation.

8. PLACE OF PERFORMANCE: Building 3, Fire Station #1 1001 Boston Ave and Building 1314, Fire Station 2, 721 W Artillery Way, Fairchild AFB, WA

9. PERIOD OF PERFORMANCE: Project shall not exceed 300 days after contract award.

10. HOURS OF OPERATION: Hours of operation are 0700-1630 Monday through Friday, excluding Federal Holidays and any other designated down day. Work can be done at other than the normal hours of operation with the approval of the Contracting Officer. The contractor shall coordinate in advance all hours of work and any service interruptions with 92 CES/CEF point of contact.

11. APPENDICES:

Appendix A: Building 3 Floor Plan Appendix B: Building 1314 Floor Plan

P R O J E C T

N U M B E R

P R O J E C T

N A M E

S H E E T

N A M E

Sheet reference number

Sheet of

D E P A R T M E N T

O F

T H E

A I R

F O R C E

C

IV

IL

E

N G

IN

EE

R S

Q C

.E .N

.M .E

FA

IR

C

H

IL

D A

.F .B

W

A

D e s i g n e d b y

D w n b y

C h k b y

P l o t

S c a l e

F i l e

N a m e

D a t e

D r a w i n g

N u m b e r

D e s c r i p t i o n

S y m b o l

A p p r o v e d

D a t e

S y m b o l

D e s c r i p t i o n

A p p r o v e d

D a t e

M A S

TE

R F

LO

O

R P

LA

N

FL

O

O R

(G

EO

B A S E)

(E A

IN

IT

IA

L

N

TS

D A

TE

U P D A T E D

P E R

E N T E R

P R O J

I N I T I A L

A B C D E F G H

25QA921 Statement of Work (SOW).pdf
Appendix A - Buildling 3 Floor Plan.pdf
Appendix B - Buildling 1314 Floor Plan.pdf

File details come from the government source that posted it. Updated .