This document is a Surface Surveillance Systems Inspection Report for an ASDE-3 radar system located at Houston's IAH Remote Tower, conducted on 04/07/2022. The comprehensive inspection aimed to assess the potential life extension of the antenna and tower, identifying several critical maintenance recommendations including replacing the hatch support arm, repainting the tower, replacing the flex waveguide, repairing the belly pan, addressing hoist and elevator maintenance, and installing cable clamps. The inspection utilized a color-coded deficiency assessment system (green, yellow, red) to categorize issues across 12 different system components, with recommendations focusing on preserving the system's operational integrity and extending its service life.

The related federal contract opportunity (Solicitation Number 6973GH-25-R-00115) is a competitive solicitation by the Federal Aviation Administration for QP-2 Paint Contractors to prepare, remove, and repaint the existing ASDE Tower and Shelters at Houston, TX. The solicitation is 100% set-aside for Small Businesses, with a firm fixed-price contract anticipated. Key dates include a site visit on April 3, 2025, questions due by April 9, 2025, and proposal submissions due by April 15, 2025, at 5:00 PM Central Time. Proposals will be evaluated based on the lowest priced quote that is fully responsive and responsible.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Surface Surveillance Systems Inspection Report 1

Surface Surveillance Systems

Inspection Report (ASDE)

Site Name: IAH Remote

Survey Date: 04/07/2022

Radar Information

System ASDE-3

Site ID IAH Remote Tower

Tower Height 140ft

Shipping Address

Physical Site Address

Latitude 29.982396

Longitude -95.363775

Asset Serial Numbers:

Detection Equipment

Set N008

Pedestal Assembly M001

Antenna Assembly M001

Drive Motor

Slipring 216-R03

Rotary Joint 1846

Antenna

PERSONNEL INFORMATION

Lead Technician / Engineer

Randy Mitchell Phone # 405.514.5470 E-mail don.randy.mitchell@faa.gov

Assessment Technician

Ronnie Medlinger Phone # E-mail ronnie.ctr.medlinger@faa.gov

Site Escort Rodney Edgin Phone # 281.784.7623 E-mail rodney.a.edgin@faa.gov

SSC Manager Jennifer Lemmon Phone # 281.209.8604 E-mail jennifer.l.lemmon@faa.gov

Surface Surveillance Systems Assessment Report 2

Introduction

The PMO desires to extend the life of ASDE antennas up to 10 years until a new antenna is approved and installed, and extend the life of the ASDE towers up to 20 years to support the new antennas.

This ASDE inspection project is an input to the PMO to aid their decision-making regarding what tasks need to be performed at each site to meet these desires.

The inspection project includes a hands-on inspection of the physical condition and functionality or serviceability of site assets including the tower, antenna system, and shelter buildings to determine whether the standards and tolerances for operations are being maintained. When the existing condition, functionality or serviceability are determined to be out of required standards and tolerances a corrective action has been provided to facilitate repairs.

Recommendations

1. Order and replace hatch support arm for the top gate access to the maintenance platform.

2. Repaint tower.

3. Replace flex waveguide on bottom side of the rotary joint.

4. Repair or replace belly pan. If a replacement part is available, then it can be ordered and replaced. If no replacement parts are available, then the part can be cleaned, and the groove repaired using epoxy resin. Pan is also missing more than half its latches; the latches will have to be ordered and installed.

5. Contact hoist company for maintenance to the hoist. Replace if necessary.

6. Have elevator inspected by a certified company.

7. During installation of coaxial cables on tower the installation contractor did not use any cable clamps or cable supports. Recommend that clamps are purchased and installed using 20 each size 7/8’’ cable clamps and 20 each size ½’’ cable clamps plus hardware to attach clamps to tower structure.

Surface Surveillance Systems Assessment Report 3

Assessment Deficiency Report

• Green: Minor issues noted due to non-compliance with a current standard.

• Yellow: Moderate issues identified that should be corrected when possible, but is not an immediate concern.

• Red: Critical issues identified that may affect personnel safety, cause a system outage, or damage to equipment. These issues require immediate attention.

Critical Moderate Minor No Issues Not

Inspected

1. Tower

2. Concrete Foundation

3. Tower Painting and Galvanization

4. Shelters

5. Waveguide

6. Lightning Protection System

7. Main Bearing / Drive System

8. Rotary Joint

9. Antenna Junction Box Enclosures

10. Antenna / Rotodome / Radome

11. Hoist / Davit Crane

12. Elevator

A full summary and site specific notation can be referenced in the following sections of this report for more detail on each observation recorded.

Surface Surveillance Systems Assessment Report 4

SECTION 1

Tower

Yes No Comments

1.1 Are there any signs of distress or failure to the

air terminal?

1.2 down conductor?

1.3 hardware?

1.4 mounting hardware?

1.5 obstruction tower lights?

1.6 exterior lighting fixtures?

1.7 Is there a need to replace the exterior lighting

fixtures with LED light bulbs?

1.8 conduits?

1.9 Is there a need to replace the conduits with PVC

coated rigid steel conduits?

1.10 grate hatch / lifting support piston arm?

Needs new piston arm

1.11 steel junction box?

1.12 Is there a need to replace the current junction

box with a stainless steel junction box?

1.13 safety interlocks?

Notes: The Top gate access to Maintenance platform needs the hatch support arm replaced. A replacement will need to be ordered and installed.

Surface Surveillance Systems Assessment Report 5

SECTION 2

Concrete Foundation

Yes No Comments

2.1 Have grout pads underneath base plates

deteriorated or otherwise require maintenance?

2.2 Does the foundation have excess spalling, cracking, or surface erosion?

2.3 Does the foundation appear to have been repaired

in the past?

2.4 Are there any other signs of distress or failure?

Explain.

Notes:

SECTION 3

Tower Painting and Galvanization

Yes No

3.1 Is the tower painted?

3.2 If painted, is the paint peeling?

3.3 If painted, based on visual observation, what is the approximate percentage of surface area on the tower that needs to be re-painted?

100%

3.4 Is the tower hot dipped galvanized?

3.5 Are there bird feces or other foreign substances present on the tower? If applicable, describe extent, severity, and whether work will be affected.

Notes: The paint is faded and thin in areas so that you can see the galvanized metal. Tower is painted in orange / white sections.

Surface Surveillance Systems Assessment Report 6

SECTION 4

Shelters

Yes No Comments

4.1 Base of Tower Equipment Shelter

a. Are there signs of distress or failure to the space heater?

b. Are there signs of distress or failure to the ventilation hood or screen?

c. Is there a need to replace the ventilation screen with a steel bug weave screen?

d. Are there signs of distress or failure to the door frames?

4.2 Second Level Equipment Shelter

4.3 Below Antenna Equipment Shelter

e. Are there signs of distress or failure to the safety interlocks?

4.4 Engine Generator Shelter

e. Are there any signs of corrosion on the fuel tanks?

f. Are there signs of distress or failure to the transformer or the protective bollards?

Surface Surveillance Systems Assessment Report 7

SECTION 5

Waveguide

Yes No Comments

5.1 mounting brackets/hardware?

5.2 Is there any damage to the waveguide?

Rubber piece under the rotary joint is weather cracking.

5.3 Are there any signs of corrosion? (fading, peeling, cracked) Flex rubber pieces are weather cracking.

5.4 Are there any issues with the operation of the

pressurize system?

5.5 Are there any issues with the joint weld condition?

(corroded/cracked)

5.6 Compressor cycle time (on – on)

Notes: The flex waveguide section that attaches to bottom of Rotary Joint should be replaced. This section of waveguide will have to be ordered and installed.

SECTION 6

Lightning Protection System

Yes No Comments

6.1 Does the system show signs of being in less than

generally good repair?

6.2 Are there loose connections that might result in

high-resistance joints?

6.3 Has any part of the system been weakened by

corrosion?

6.4 Have any of the conductors or grounding electrodes

been severed?

6.5 Are any conductors or system components

fastened insecurely to its mounting surfaces?

6.6 Are any conductors or system components subject

to accidental displacement?

6.7

Have any modifications been made or appurtenances added that require additional bonding to the system?

6.8 Is there any visual hardware damage?

Surface Surveillance Systems Assessment Report 8

SECTION 7

Main Bearing / Drive System

Yes No Comments

7.1 Drive – Start drive independently from a stall

a. Is there excessive noise or vibration?

b. Are there any signs of corrosion? (fading, peeling, cracked)

c. Are there any signs of distress or failure?

d. Are there any observed oil leaks (ASDE-X)

7.2 following: (ASDE-3)

a. Intermediate Shaft

b. Main Bearing

c. Tensioner

d. 50mm Belt

e. 85mm Belt

f. Slip Clutch

7.3 Notate date of last replacement for the following:

(ASDE-3)

a. Intermediate Shaft

b. Main Bearing

c. Tensioner

d. 50mm Belt

e. 85mm Belt

f. Slip Clutch

7.4 Workspace height below drives in ft. (ASDE-3) 3ft

7.5 Are there any issues with the accessibility of the

workspace? (ASDE-3)

Notes: The Belly Pan / Drive cover has broken latches and a groove from loose or broken drive belts. If available a new cover should be ordered, if not available then the groove can be fixed using epoxy and new latches can be ordered and installed.

Surface Surveillance Systems Assessment Report 9

SECTION 8

Rotary Joint

Yes No Comments

8.1 Install date of rotary joint

8.2 Performance data VSWR

8.3 Is there excessive noise?

8.4 Are there any signs of corrosion? (fading, peeling, cracked)

8.5 Are there signs of distress or failure to the rotary

joint?

8.6 Are there signs of distress or failure to the cabling

and waveguide on the top side of the rotary joint?

8.7

Are there signs of distress or failure to the cabling and waveguide on the bottom side of the rotary joint?

SECTION 9

Antenna Junction Box Enclosures

Yes No Comments

9.1 Junction box orientation

9.2 Are there any issues with the condition of the

box?

9.3 Are there any issues with the operation of the

safety switch?

9.4 Are there signs of distress or failure to the wiring, relays, or contactors inside the box?

9.5 Are there signs of distress or failure to the conduit

& cabling from the junction box to the drives?

9.6 Are there any signs of corrosion? (fading, peeling, cracked)

9.7 Are there signs of distress or failure to the

mounting hardware?

9.8 Are there any signs of water intrusion?

9.9 Are there any signs that the penetrations of the

box are not weathertight?

Surface Surveillance Systems Assessment Report 10

SECTION 10

Antenna / Rotodome / Radome

Yes No Comments

10.1 Antenna Type (ASDE-3, ASDE-X Terma, or ASDE-X

Easat)

ASDE-3

10.2 Antenna Structure (riser, special mounting, etc.)

10.3 Antenna

a. Notate date of last repair

b. Are there any signs of corrosion (fading, peeling, cracked)

c. Are there any signs of distress or failure to the wiring?

d. Are there any signs of distress or failure to the electrical connections?

10.4 Rotodome (if applicable)

a. Are there any issues with the paint or laminate condition?

Painted 4/7/22

b. Are there any signs of corrosion on the threshold door?

c. Are there any signs of distress or failure to the wiring?

d. Are there any signs of distress or failure to the waveguide?

e. Are there any signs of distress or failure to the fans/heaters?

f. Are there any signs of distress or failure to the flashing at the rotodome base?

10.5 Radome (if applicable)

a. Are there any observed cracks in the caulking?

b. Does the paint appear to be faded?

c. Do any panels appear to be damaged?

Surface Surveillance Systems Assessment Report 11

SECTION 11

Hoist / Davit Crane

Yes No Comments

11.1 Is there a hoist or a Davit crane present? (If so, specify type) Chain Hoist

11.2 If present, are there any signs of distress or failure

to the following:

a. Chain Rusted

b. Hook Rusted

c. Cable

11.3 If present, are there any safety concerns? Hoist is heavily corroded

11.4 Are there any signs of corrosion to the

chain/hook/cable? (fading, peeling, cracked) Rusted

11.5 Are there any signs of corrosion to the pendant?

(fading, peeling, cracked)

Notes: A Hoist Company should be contacted to perform inspection and maintenance on the Hoist or replace if required.

SECTION 12

Elevator

Yes No Comments

12.1 Is the elevator operational?

Needs to be inspected by an elevator company.

12.2 following:

a. Rail

b. Mounting Hardware

c. Motor

d. Safety Interlocks

12.3 Is the emergency egress ladder present?

Notes: The Elevator is operational, but the site has tagged it out for use by the Site Technicians until it can be inspected by Elevator Company. Will need to contact a vendor and have it inspected.

Surface Surveillance Systems Assessment Report 12

SECTION 13

PHOTO CHECKLIST

Capture each photo in accordance with the sequence and description provided Comments

Site 1 Full tower and compound (site)

2 Looking at site from the North/A Face

3 Looking at site from the East/ B Face

4 Looking at site from the South/ C Face

5 Looking at site from the West/ D Face

Structure 6 Leg A from outside looking up (indicate with magic marker each leg)

7 Leg B from outside looking up (indicate with magic marker each leg)

8 Leg C from outside looking up (indicate with magic marker each leg)

9 Leg D from outside looking up (indicate with magic marker each leg)

10 Tower foundation @ the base of leg A

11 Tower foundation @ the base of leg B

12 Tower foundation @ the base of leg C

13 Tower foundation @ the base of leg D

14 Base of tower shelter

15 Second Level Shelter

16 Below antenna shelter

17 Equipment shelter

18 Drive assembly

19 Rotary Joint

20 Antenna Junction Box

21 Antenna Front

22 Hoist

23 Elevator

Deficiencies List pictures of deficiency observed

Hole work into belly pan

Belly pan missing clips

Surface Surveillance Systems Assessment Report 13

SECTION 14

REFERENCE IMAGES

Insert pictures from site in order of picture checklist

Full tower and compound (site)

Surface Surveillance Systems Assessment Report 14

Looking at site from the North / A Face

Looking at site from the West / D Face

Drive Assembly

Hoist

Surface Surveillance Systems Assessment Report 15

Elevator

Top of lower shelter

Hole worn into belly pan

Belly pan missing clips

Surface Surveillance Systems Assessment Report 16

Surface Surveillance Systems Assessment Report 17