Att 7 - 10.MP.104.pdf
PDF 2 MB Posted
- Solicitation number
- 36C77625R0084
About this file
This document is a detailed HVAC piping plan drawing for Level 4 of the Replacement Medical Center Facility at Eastern Colorado Health Care System in Aurora, Colorado. The technical drawing shows an extensive network of heating, cooling, and water pipes with various pipe sizes ranging from 3/4" to 6", including chilled water supply and return lines (CWS/CWR), hot water supply and return lines (HWS/HWR), and chilled/hot water pipes. The drawing includes numerous room identifications, such as offices, exam rooms, corridors, and technical spaces, with specific location codes like 10-04-B8-07 for an exam room, and provides a comprehensive view of the mechanical infrastructure for the building's fourth level, with a scale of 1 1/8" = 1'-0" and a north-oriented layout.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Att 14- Phase I Tech Questions responses - 554-21-700P2 CO.pdf | ||
| S06- 36C77625R0084 0001.pdf | ||
| Att 10 - Limitations on Subcontracting - Construction.docx | DOCX document | |
| Att 6- 10.MP.103.pdf | ||
| Att 5 - 10.MP.102.pdf | ||
| Att 4- 10.MH.104.pdf | ||
| Att 2- 10.MH.102.pdf | ||
| Att 11 - Division Cost Breakdown.xlsx | XLSX spreadsheet | |
| Att 3- 10.MH.103.pdf | ||
| Att 1- SOW 554-21-700P2 EHRM Infra Upgrades.pdf | ||
| Att 12- Service Rates - Adams County 09.15.25.pdf | ||
| Att 9 - PPQ.docx | DOCX document | |
| Att 13- DBA Rates - Adams County - 09.15.25.pdf | ||
| Att 8 - PEQ.docx | DOCX document | |
| 36C77625R0084.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
DN
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
M A
IN
T
A
C C
E S
S
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
M A
IN
T
A
C C
E S
S
M A
IN
T
A
C C
E S
S
M A
IN
T
A
C C
E S
S
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
M A
IN
T
A
C C
E S
S
MAINT.
ACCESS
MAINT.
ACCESS
MAINT.
ACCESS
M A
IN
T
A
C C
E S
S
MAINT.
ACCESS
MAINT.
ACCESS
M A
IN
T
A
C C
E S
S
M A
IN
T
A
C C
E S
S
MAINT.
ACCESS
M A
IN
T
A
C C
E S
S
M
AIN
T.
AC
C
ESS
MAINT.
ACCESS
10-HWCUH7
10-HWCUH8 10-WCHP16
10-WCHP17
10-WCHP18
10-WCHP20
10-WCHP19
1 1/4" CWS
1 1/4" CWR
1 1/4" CWS
1 1/4" CWR
5" CHS
5" CHR
1 1/4" CWR
1 1/4" CWS
1" CWR
1" CWS
1" CHR
1" CHS
1" CWS1" CWR
1 1/4" CHS
1 1/4" CHR
2" HWS
2" HWR
2" HWR
2" HWR
2" HWS
3/4" CWR
3/4" CWS
2" HWR2" HWS
6" CHS
1" CHS
1 1/4" CHR 1 1/4" CHS
2" HWS 2" HWR
2" HWS
2" HWR
2" HWS
2" HWR
1 1/4" CHS
1 1/4" CHR
10 - FP2 - 4.3
10 - FP2 - 4.2
10 - FP2 - 4.1
10 - FP2 - 4.4
10 - FP2 - 4.5
10 - FP2 - 4.6
10 -2 - 4.7
10 - FP2 - 4.8
10 - FP2 - 4.9
10 - FP2 - 4.10 10 -2 - 4.11
10 - FP1 - 4.1
10 - FP1 - 4.2
10 - FP1 - 4.3
10 - FP1 - 4.4
10 - FP1 - 4.5
10 - FP1 - 4.6
10 - FP1 - 4.7
10 - FP1 - 4.8
10 - FP1 - 4.9
10 - FP1 - 4.10
10 - FP1 - 4.11
10 - FP1 - 4.12
10 - FP1 - 4.1310 - FP1 - 4.14
10 - FP1 - 4.15
10 - FP1 - 4.16
10 - FP1 - 4.17
10 - FP2 - 4.12
10 - FP2 - 4.13
10 - FP2 - 4.14
10 - FP2 - 4.15
2" HWS
10 - TU2 - 4.7
10 - TU2 - 4.8
10 - TU2 - 4.9
10 - TU2 - 4.6
10 - TU2 - 4.5
10 - TU2 - 4.1
10 - TU2 - 4.2
10 - TU2 - 4.3
T U
.4
10 - TU2 - 4.13
10 - TU1 - 4.16 10 - TU1 - 4.14
10 - TU1 - 4.1510 - TU1 - 4.17
10 - TU1 - 4.13 10 - TU1 - 4.11
10 - TU1 - 4.12
10 - TU1 - 4.10
10 - TU1 - 4.9
10 - TU1 - 4.8
10 - TU1 - 4.7
10 - TU1 - 4.6
10 - TU1 - 4.5
10 - TU1 - 4.2
10 - TU1 - 4.3
10 - TU1 - 4.4
10 - TU2 - 4.11
10 - TU2 - 4.10
10 - TU2 - 4.12
10 - TU1 - 4.1
T T T
T
T
T
T
T
T
TT
T
T
T
T
T T
T
T T T
T T T T T T T
T
T T
T
T
T
T
T
T
T
TTT
TT
T
T
T T
TT
T
T
T
T
T
T
T
T
T
T
T
T
T T T
T
T
T
2" HWS
1"
6" CHR
2" LPC
3" LPS
1 1/2" LPC
1" LPS
3/4" LPC
3" LPS
1 1/2" LPC
5" CHR
5" CHS
1 1/2" LPC
3" LPS 1" LPS
3/4" LPC
5" CHS
5" CHR
1" CHR
HWS/R UP
TO HWUH
1 1/4" CWS
1 1/4" CWR
1.1
2.5
11.5
A
A.1
B
B.1
B.5
B.7
C
C.9
D
E
10-SE11
ELEV
10-ST3
STAIR
A4-216
TELECOM
10-04-C3-04
A4-221
ELEC
10-04-C6-02
A4-343
TELECOM
10-04-C8-06 A4-329
ELEC
10-04-C10-02
A4-104
LOBBY
10-04-B6-02
A4-100
VEST
10-04-C6-03
10-04-C3-05
COMMUNICATIONS
10-04-C8-05
COMMUNICATIONS
A4-223
FEMALE PUBLIC
TLT
10-04-C5-03
10-04-C8-07
EQUIP STOR
A4-334
HAC
10-04-C7-02
A4-243
STAFF TLT
10-04-B3-12
A4-326
STAFF LOUNGE
10-04-C11-02A4-227
MALE PUBLIC TLT
10-04-C5-01
A4-276
OFFICE
10-04-A2-01 A4-256
CONF
10-04-A5-02
A4-278
OFFICE
10-04-A1-02
A4-253
MDG/CC1
10-04-A1-01
A4-241
STAFF TLT
10-04-B3-13
A4-250
SECR/WAIT
10-04-B2-01
A4-251
MDOS/CC1
10-04-B1-02
A4-249
MDSS/CC1
10-04-B1-03
10-04-B3-09
OFFICE
A4-245
SGN
10-04-B1-05
A4-247
OFFICE
10-04-B1-04
A4-274
NCOIC/RMO/
CSS/SUP1
10-04-A2-02
A4-272
OIC RMO
10-04-A2-03
10-04-B2-02
TECH
10-04-B2-03
TECH
10-04-B2-04
TECH
A4-273
TECH
10-04-B2-05
10-04-B2-06
TECH
A4-238
OFFICE
10-04-B3-10
10-04-B2-08
COPY/FAX
ALCOVE
A4-239
10-04-B3-14
10-04-B3-15
10-04-C3-01
TECH 10-04-C3-02
TECH
A4-214
FILE
10-04-C3-06
A4-101
WAIT
10-04-C6-05
A4-106
RECEPT
10-04-B6-01
A4-350
EXAM
10-04-B8-07
A4-352
EXAM
10-04-B8-08 A4-354
EXAM
10-04-B8-09
A4-357
EXAM
10-04-B9-10
A4-356
EXAM
10-04-B9-05
A4-358
EXAM
10-04-B9-06 A4-360
EXAM
10-04-B9-07
A4-362
EXAM
10-04-B10-06
A4-355
EXAM
10-04-B9-09
A4-345
EXAM
10-04-B7-04
A4-345A
ISOLATION TLT
10-04-B7-05
A4-353
EXAM
10-04-B8-12 A4-349
PATIENT TLT
10-04-B8-10
A4-253A
STAFF TLT
10-04-B1-01
A4-346
EXAM
10-04-B7-02 A4-348
EXAM
10-04-B7-03
A4-332
TREATMENT
10-04-B11-07
A4-330
PROCEDURE
10-04-C11-01
10-04-B3-08
OFFICE
A4-209
OFFICE
10-04-C4-06
A4-391
OFFICE
10-04-B11-06
A4-218
COPY/FAX
10-04-C3-03
A4-265
GPM1
10-04-B3-07
A4-261
HCI/UM
10-04-B4-04
A4-263
HCI/UM
10-04-B4-01
A4-374
MED TECH
10-04-B8-02 10-04-B8-03
MED TECH
10-04-B9-03
MED TECH 10-04-B10-01
MED TECH
A4-390
MED TECH
10-04-B11-03
10-04-B11-01
MED TECH
10-04-B8-01
OFFICE
10-04-B8-04
OFFICE
A4-384
OFFICE
10-04-B10-02
A4-324
FAMILY HEALTH
10-04-C11-06
A4-322
NURSE OIC1
10-04-C11-05
10-04-B10-03
OFFICE
10-04-B11-02
OFFICE
10-04-B11-04
OFFICE
10-04-C11-03
PAT LOCKERS
A4-376
OFFICE
10-04-B8-05 A4-378
OFFICE
10-04-B8-06
A4-380
OFFICE
10-04-B9-01
A4-382
OFFICE
10-04-B9-02
A4-386
OFFICE
10-04-B10-04 A4-388
OFFICE
10-04-B10-05
A4-213
STAFF LOUNGE
10-04-C3-07
A4-364
CLEAN UTIL
10-04-B10-07
A4-366
STERILE
10-04-B10-08
A4-365
EQUIP STOR
10-04-B10-11
A4-351
SAT LAB
10-04-B8-11
A4-328
SOILED UTIL
10-04-C11-04
A4-331
W.C. ALCOVE
10-04-B10-12
A4-370
RECEP/OFFICE
10-04-B7-01
A4-303
RECEPT
10-04-C8-10A4-301
WAIT
10-04-C7-09
A4-303A
PAT RECORDS
10-04-C8-12 A4-313
OFFICE
10-04-C10-08
A4-311
OFFICE
10-04-C10-07
A4-304
INTAKE/
TRIAGE/TEST
10-04-C8-09
A4-302
INTAKE/
TRIAGE/TEST
10-04-C8-08
A4-309
OFFICE
10-04-C9-14
A4-307
OFFICE
10-04-C9-13
10-04-C8-11
OUTREACH
NURSE
A4-317
SOCIAL WORKER
10-04-C11-08 A4-315
SOCIAL WORKER
10-04-C11-07
A4-310
CADAC OFFICE
10-04-C9-11
A4-305
COPY/FAX
10-04-C8-13
A4-336
NCOIC MHS
10-04-C7-03
A4-327
STAFF TLT
10-04-C10-04
A4-321
STAFF TLT
10-04-C10-05
10-04-C9-07
TECH OFFICE
10-04-C9-04
TECH OFFICE
10-04-C9-02
TECH OFFICE
A4-306
TECH OFFICE
10-04-C9-03
10-04-C9-06
TECH OFFICE
10-04-C9-05
TECH OFFICE 10-04-C9-08
TECH OFFICE
A4-312
GROUP THERAPY
10-04-C10-03
A4-319
COMP TESTING
10-04-C11-09
A4-338
RECEP
10-04-C7-05
A4-340
FITTING/DISPENSING
10-04-C8-01
A4-338A
VISUAL/FUNDUS
CAMERA
10-04-C7-04
A4-103
PHARMACIST
OFFICE
10-04-C7-08
A4-102
POS PHARMACY
10-04-C6-07
A4-220
COPY/FAX
10-04-B2-09
A4-262
NCOIC TOPA
10-04-A4-02
A4-264
OIC TOPA
10-04-A4-01
10-04-B4-07
TECH OFFICE
A4-236
TECH OFFICE
10-04-B4-03
10-04-B4-02
TECH OFFICE
A4-232
TECH OFFICE
10-04-B4-08
A4-258
OFFICE
10-04-A5-01
A4-260
OFFICE
10-04-A4-03
10-04-B5-09
RECORDS
WINDOW
A4-235
RECORDS STOR
10-04-B4-11
10-04-B5-08
TECH OFFICE
A4-257
MEB
10-04-B5-01
A4-255
MEB
10-04-B5-04
A4-259
BCAC
10-04-B4-06
10-04-B5-13
TECH OFFICE
10-04-B5-12
TECH OFFICE
A4-231
TECH OFFICE
10-04-B5-11
A4-234
OFFICE
10-04-B4-05
A4-105
RECEPT
10-04-B5-06
10-04-B5-02
TECH OFFICE
A4-230
TECH OFFICE
10-04-B5-03
A4-203
INFO/NCOIC
10-04-C4-09
10-04-C5-13
OFFICE
10-04-C5-12
OFFICE
10-04-C5-11
OFFICE
10-04-C5-08
CUSTOMER
SERVICE DESK
A4-201A
COMPUTER RM
10-04-C5-05
10-04-C4-10
MEDIA
A4-201
UPS
10-04-C5-07
A4-206
EQUIP STOR
10-04-C4-03
10-04-C5-06
WORK
A4-240
OFFICE
10-04-B3-06
A4-217
CLASSROOM
10-04-C2-01
10-04-B3-01
OFFICE
10-04-B3-02
OFFICE
10-04-B3-03
OFFICE
A4-269
OFFICE
10-04-B3-04
A4-205
FACILITY MGMT
10-04-C4-08
10-04-C4-07
FACILITY MGMT
A4-339
EYE LANE
10-04-C8-04
A4-337
EYE LANE
10-04-C7-06
A4-ST1
EX STAIR 1
10-04-C4-01
A4-237
VEST
10-04-B4-10
A4-225
HAC
10-04-C5-02 10-04-C4-02
SHAFT
AE-V01
ELEV
10-04-C6-01
AE-V03
ELEV
10-04-C6-04
10-04-C9-01
SHAFT
A4-S01
EX ELEV 4
10-04-C10-01
A4-ST2
EX STAIR 2
10-04-B10-09
10-04-A3-03
ARMY/NAVY
LIASON
A4-266
ARMY/NAVY
LIASON
10-04-A3-04
A4-268
OFFICE
10-04-A3-02
A4-270
CODER
10-04-A3-01
A4-267
AUDITOR
10-04-B3-05
A4-207
OFFICE
10-04-C4-05
A4-228
TECH
10-04-B5-05
10-04-B5-10
TECH OFFICE
10-04-C5-10
OFFICE
A4-359
STOR
10-04-B9-11
A4-308
CASE MANAGER
10-04-C9-10
A4-C11
CORRIDOR
10-04-C9-12
A4-C15
CORRIDOR
10-04-C10-06
A4-C08
CORRIDOR
10-04-A4-04
A4-C17
CORRIDOR
10-04-B9-08
A4-C19
CORRIDOR
10-04-B9-04
A4-C10
CORRIDOR
10-04-C7-07
A4-C13
CORRIDOR
10-04-C8-03
A4-C05
CORRIDOR
10-04-B4-09
A4-C01
CORRIDOR
10-04-C4-04
A4-C06
CORRIDOR
10-04-B3-11
A4-C03
CORRIDOR
10-04-C2-02
A4-C07
CORRIDOR
10-04-B2-07
A4-C09
CORRIDOR
10-04-A2-04
A4-C12
CORRIDOR
10-04-C7-01
A4-363
ELEV VEST
10-04-B10-10
10-04-C9-09
VEST
A4-C14
CORRIDOR
10-04-C8-02
10-04-C6-08
VEST
10-04-C5-09
HALL
10-04-C5-04
VEST
10-04-B5-07
HALL
10-04-B11-05
HALL
A4-393
STORAGE
10-04-11.5B.7-01
A4-392
LOBBY
10-04-12B.1-01
A4-C16
CORRIDOR
10-04-C11-10
A4-C20
CORRIDOR
10-04-B11-08 10-04-B8-13
CORRIDOR
A4-C18
CORRIDOR
10-04-B7-06
10-04-B10-13
CORRIDOR
A4-C02
CORRIDOR
10-04-C3-08
10-04-B5-14
CORRIDOR
HVAC PIPING FLAG NOTES:
TERMINATE 1 1/4" CHS/R WITH VALVE AND CAP WITHIN 3' OF
WCHP FOR FUTURE CHILLED WATER FAN COIL UNIT (IFO
PACKAGE AFTER ENERGY CENTER IS ON-LINE).
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
IB
S
IB
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E o n e e ig h th i n c h o n e f o o t
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
Professional Seal
/9
/2
:1 :3
P
M F
R
C
-I N
C \D e n v e r
V A
\1 -C
B S
\R e v it \M
H -C
B S
-S h e e ts ru s s .e c k s te in K
U T
U Y
.r v t
10.MP.104
LEVEL 4 HVAC PIPING PLAN
CLINIC BUILDING (SOUTH)
07/15/2011
1/8" = 1'-0"1
LEVEL 4 HVAC PIPING PLAN
NORTH
0' 4' 8' 16' 32'