ATT 6 - 675-103 - 2017 Orlando VAMC ACM Report Compressed FINAL.pdf

PDF 19 MB Posted

Attached to
Y1DZ--675-103 Create Cardiovascular Center Minor Construction - Lake Nona, FL VAMC
Solicitation number
36C77625B0030
Issued by

About this file

This document is an Asbestos Survey Report for the Orlando VA Medical Center Lake Nona Campus, conducted by MECX, Inc. in September 2017. The comprehensive survey covered 10 buildings constructed in 2015, including a clinic, hospital, warehouse, main entry, central energy plant, service entry, domicile, chapel, community living center, and simulation learning center, with a total approximate area of 2,302,383 square feet.

The survey, performed by licensed asbestos consultants, collected approximately 450 representative bulk samples from accessible interior spaces, following EPA and OSHA regulatory requirements. Notably, the roofs and mechanical systems were excluded from sampling, and materials must be assumed asbestos-containing until tested. Despite the thorough investigation, the report emphasizes that hidden suspect materials may exist in inaccessible areas such as above ceilings and in wall cavities. Ultimately, no asbestos-containing materials (ACM) were identified in the samples collected from any of the buildings during this survey.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS SURVEY REPORT

Buildings: 1, 2, 5, 6, 7, 8, 9, 10, 11, 13, Interstitial of 1 & 2

Orlando VA Medical Center Lake Nona Campus Orlando, FL 32827

MECX Project Number: 1244.020C.02

Prepared for:

Department of Veterans Affairs

Orlando VA Medical Center 13800 Veterans Way

Orlando, FL 32827 Order No. VA248-17-P-2230

Matthew Haak

TDSHS 10-5791

13 September 2017

ASBESTOS SURVEY REPORVEY REPORT

ORLANDO VAMC, LAKE NONA CAMPUS

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

TABLE OF CONTENTS

Section Page

1.0 INTRODUCTION

1.1 REGULATORY REQUIREMENTS

1.2 SURVEY BUILDINGS

2.0 SCOPE OF WORK

2.1 METHODOLOGY

2.2 SAMPLING STRATEGY

Surfacing Materials Thermal Systems Insulation Miscellaneous Materials Non-Suspect ACM Condition Classification

2.3 SURVEY DESCRIPTION

3.0 FINDINGS PER BUILDING

3.1 BUILDING 1, CLINIC

Building 1 - Suspect Asbestos-Containing Materials Building 1 - Samples Reported as Asbestos-Containing

3.2 BUILDINGS 2 AND 5, HOSPITAL AND WAREHOUSE

Buildings 2 and 5 - Suspect Asbestos-Containing Materials Building 2 and 5 - Samples Reported as Asbestos-Containing

3.3 BUILDING 6, MAIN ENTRY

Building 6 - Suspect Asbestos-Containing Materials Building 6, Samples Reported as Asbestos-Containing

3.4 BUILDING 7, CENTRAL ENERGY PLANT

Building 7- Suspect Asbestos-Containing Materials Building 7 - Samples Reported as Asbestos-Containing

3.5 BUILDING 8, SERVICE ENTRY

Building 8 - Suspect Asbestos-Containing Materials Building 8 - Samples Reported as Asbestos-Containing

3.6 BUILDING 9, DOMICILE

Building 9 - Suspect Asbestos-Containing Materials Building 9 - Samples Reported as Asbestos-Containing

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.7 BUILDING 10, CHAPEL

Building 10 - Suspect Asbestos-Containing Materials

3.8 BUILDING 11, COMMUNITY LIVING CENTER

Building 11 - Suspect Asbestos-Containing Materials Building 11 - Samples Reported as Asbestos-Containing

3.9 BUILDING 13, SIM LEARNING

Building 13 - Suspect Asbestos-Containing Materials Building 13 - Samples Reported as Asbestos-Containing

4.0 CONCLUSIONS AND RECOMMENDATIONS

5.0 LIMITATIONS

APPENDICES

A – Asbestos Summary Table B – Laboratory Results C – MECX’s Project Team Certifications D – Photo Log

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

ACRONYMS

A Asbestos- Containing Building Materials (ACBM) · 3 asbestos-containing material (RACM) · 3 asbestos-containing materials (ACMs) · 1

D Department of Veterans Affairs (VA) · 1

E Environmental Protection Agency (EPA) · 1 EPA Asbestos Model Accreditation Plan (MAP) · 1

H heating, ventilation and air conditioning (HVAC) · 2 homogeneous area (HA) · 4 homogeneous areas (HA) · 5

L Loflin Environmental Services, Inc. (Loflin) · 3

N National Emissions Standards for Hazardous Air Pollutants (NESHAP) · 1 National Institute of Standards and Technology (NIST) · 3 National Voluntary Laboratory Accreditation Program (NVLAP) · 3

O Occupational Safety and Health Administration (OSHA) · 1

P polarized light microscopy (PLM) · 3

T Texas Department of State Health Services (TDSHS) · 1 the EPA Asbestos Hazard Emergency Response Act (AHERA) · 1 thermal system insulation (TSI) · 2

U United States (U.S.) · 1

V VA Medical Center (VAMC) · 1

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

1.0 INTRODUCTION

MECX, Inc. (MECX) performed a survey for asbestos-containing materials (ACMs) at ten buildings within the Department of Veterans Affairs (VA), Orlando VA Medical Center (VAMC), Lake Nona Campus located at 13800 Veterans Way, Orlando, FL 32827 (Site).

1.1 REGULATORY REQUIREMENTS

MECX performed the survey in order to meet requirements that are compliant with the United States (U.S.)

Environmental Protection Agency (EPA) Asbestos Hazard Emergency Response Act (AHERA) regulations (40 CFR 763), National Emissions Standards for Hazardous Air Pollutants (NESHAP) regulations (40 CFR 61, Subpart M), and the Occupational Safety and Health Administration (OSHA) Asbestos Standards (29 CFR

1910.1001 and 29 CFR 1926.1101).

MECX licensed asbestos consultants Mr. Matthew Haak (TDSHS License 10-5791) and Mr. James Murray (TDSHS License 10-5776), are Texas Department of State Health Services (TDSHS) licensed Asbestos Consultants. TDSHS licensing and training meet the U.S. EPA Asbestos Model Accreditation Plan (MAP) requirements. Training for asbestos professionals is required under the EPA Asbestos MAP which EPA issued under the Asbestos Hazard Emergency Response Act of 1986 (AHERA). The MAP requires the use of trained and accredited asbestos professionals when conducting asbestos inspections or designing or conducting response actions at schools and public and commercial buildings. It provides guidance to states on the minimum training requirements for accrediting asbestos professionals. State training programs must be at least as stringent as the MAP. The MAP established five required training disciplines:

Worker, Contractor/supervisor, Inspector, Management planner, and Project designer

As licensed Asbestos Consultants, MECX’s representatives are accredited to perform the functions of the five disciplines identified above.

MECX completed the survey between the dates of July 17, 2017 – July 19,2017.

1.2 SURVEY BUILDINGS

The following buildings as specified by representatives of the Orlando VAMC were included in this survey:

Building No. Building Use Year Built

Number of Floors

Approximate Square Feet (sf)

1 Clinic 2015 5 527,916 2 Hospital 2015 5 487,871 5 Warehouse 2015 1 56,081 6 Main Entry 2015 1 894

7 CPE 2015 1 41,900

8 Service Entry 2015 1 304

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

Building No. Building Use Year Built

Number of Floors

Approximate Square Feet (sf)

9 Domicile 2015 4 41,154 10 Chapel 2015 1 2,851

11 CLC 2015 1 117,426

13 Sim Learn 2015 1 45,000

Buildings 1 & 2 Interstitial Space 2015 1 880,000

As directed by the OVAMC, the building roofs and mechanical systems ( i.e., include heating, ventilation and air conditioning (HVAC) duct seam, patching & penetration tar and thermal system insulation (TSI)) on the roof were excluded from the survey. Therefore, MECX did not sample the roofing materials or other materials on the roofs and these materials must be assumed to be asbestos containing until such time they have been tested and shown otherwise.

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

2.0 SCOPE OF WORK

The objective of this survey, as defined by the OVAMC, was to collect representative samples of suspect friable and non-friable ACMs located in the interior and exterior building spaces, excluding roofs. In addition to collection samples for asbestos analyses, MECX also assessed the condition and quantity of the suspect materials.

2.1 METHODOLOGY

The survey consisted of inspections of reasonably accessible building components to identify suspect ACM.

MECX’s collected samples of suspect ACM in accordance with the U.S. EPA Model Accreditation Plan specified in the AHERA.

MECX placed samples in polyethylene bags with unique identification numbers and then transported the samples under chain-of-custody to Loflin Environmental Services, Inc. (Loflin), in Houston, Texas. Loflin is a licensed asbestos laboratory and a participating member in the National Institute of Standards and Technology (NIST) administered by the National Voluntary Laboratory Accreditation Program (NVLAP). Loflin analyzed bulk samples for asbestos content using polarized light microscopy (PLM), in accordance with U.S.

EPA Analytical Method EPA/600/R-93/116.

The U.S. EPA defines an ACM as material that contains greater than one percent asbestos by PLM analysis (NESHAP 40 CFR Part 61, Subpart M). When the bulk samples contained more than one layer, the laboratory analyzed each layer of the sample.

Suspect samples containing less than or equal to 1% asbestos are not considered ACM by regulatory definition. If lab analysis found that samples were asbestos-containing, then the corresponding material has to potential to be considered a regulated asbestos-containing material (RACM), according the EPA’s NESHAP regulation for renovations and demolitions (reference 40 CFR Part 61).

MECX classified suspect ACMs as either friable or non-friable. A summary of these two classifications is presented below.

Friable ACMs contain more than 1% asbestos and, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. Friable ACMs are considered RACM and, therefore, subject to U.S. EPA regulations.

Non-friable ACMs contain more than 1% asbestos and cannot be crushed with hand pressure. Non-friable ACMs are categorized as either Category I or Category II materials.

o Category I - non-friable asbestos-containing packings, gaskets, resilient floor covering, and/or asphalt roofing products.

o Category II - non-friable ACMs that are not Category I.

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

2.2 SAMPLING STRATEGY

MECX employed the sampling strategy summarized below.

Surfacing Materials MECX collected bulk samples of surfacing materials in a randomly distributed manner. The samples were representative of each homogeneous area (HA). For suspect ACM, MECX collected the following quantity of samples per HA:

HA 1, 000 sf: at least three bulk samples 1,000 sf at least five bulk samples HA > 5,000 sf: at least seven bulk samples.

Thermal Systems Insulation MECX collected at least three bulk samples of thermal systems insulation in a randomly distributed manner.

The samples were representative of each HA. For suspect ACM, MECX collected the following quantity of samples per HA:

Patched thermal system insulation: at least one bulk sample 6 linear feet or sf

Insulated mechanical systems (i.e., cementitious material on joints and valves): at least 3 bulk samples

Miscellaneous Materials MECX collected at least three representative bulk samples of each miscellaneous material (i.e., ceiling tile, floor tile, floor tile mastic, etc.) in a manner sufficient to determine if a material was ACM.

Non-Suspect ACM MECX did not collect samples from HA where it was documented that a material was not ACM.

Condition Classification MECX classified ACM as food, fair or poor condition, as described below.

Good - material which is intact and absent noticeable damage Fair - material with small/minor amounts of localized damage (generally less than 10% of the area) Poor - material with a large amount of damage (generally greater than 10% of the surface area).

2.3 SURVEY DESCRIPTION

MECX collected approximately 450 representative bulk samples of accessible interior suspect ACMs. Suspect ACMs may exist in inaccessible or hidden areas of the structure that were not observed or inspected during this investigation.

MECX also performed a limited survey of building exteriors, excluding the roofs. The estimated quantities of ACM made by MECX should be verified prior to removal, if any.

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.0 FINDINGS PER BUILDING

3.1 BUILDING 1, CLINIC

Building 1 - Suspect Asbestos-Containing Materials

MECX identified the following homogeneous areas (HA) within Building 1 and collected bulk samples of these materials for asbestos content.

1. HVAC Duct Insulation Sealant White

2. Chilled Water Insulation Sealant

3. Gray Metal HVAC Duct Seam Sealant

4. Ceiling Tile 2'x2' Beveled Edge

5. HVAC Foil Duct Insulation Sealant

6. Fire Stop Red

7. Pink Fire Sealant

8. Vinyl Floor Tile 18"x18"Beige/Green

9. Vinyl Floor Tile 18"x18"Bamboo

10. Hot Water Insulation Sealant

11. Joint Compound

12. Penetration Packing Gray

13. Roof Drain Insulation Sealant

14. Spray Applied Fire Proofing

15. Vinyl Floor Wood Pattern

16. Wall Texture

17. Cove Base

Building 1 - Samples Reported as Asbestos-Containing

ACM was not reported in the samples collected from Building 1. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas such as above ceilings and in wall cavities.

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.2 BUILDINGS 2 AND 5, HOSPITAL AND WAREHOUSE

Buildings 2 and 5 - Suspect Asbestos-Containing Materials

MECX identified the following HA within Buildings 2 and 5 and collected bulk samples of these materials for asbestos content.

1. Chilled Water Insulation Sealant

2. Ceiling Tile, 2'x2'

3. HVAC Duct Insulation Sealant

4. Foil HVAC Insulated Duct Sealant

5. Red Fire Stop

6. Purple Vinyl, 24"x24"

7. Beige Vinyl, 24"x24"

8. Gray HVAC Duct Seam Sealant

9. Hot Water Insulation Sealant

10. Joint Compound

11. Penetration Packing Gray

12. Roof Drain Insulation Sealant

13. Spray Applied Beige Fire Proofing

14. Steam Insulation Sealant

15. Sheet Vinyl Flooring, Blue

16. Vinyl Flooring Wood Pattern

17. Water Proofing Sealant Pink

18. Vinyl Cove Base Mastic

Building 2 and 5 - Samples Reported as Asbestos-Containing

ACM was not reported in the samples collected from Buildings 2 and 5. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas such as above ceilings and in wall cavities.

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.3 BUILDING 6, MAIN ENTRY

Building 6 - Suspect Asbestos-Containing Materials

MECX identified the following HA within Building 6 and collected bulk samples of these materials for asbestos content.

1. Joint Compound

2. Wall Texture

Building 6, Samples Reported as Asbestos-Containing

ACM was not reported in the samples collected from Building 6. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.4 BUILDING 7, CENTRAL ENERGY PLANT

Building 7- Suspect Asbestos-Containing Materials

MECX identified the following HA within Building 7 and collected bulk samples of these materials for asbestos content.

1. 18"x18" Pale Orange Vinyl Floor Tile

2. Chilled Water Insulation Sealant

3. Ceiling Tile

4. Duct Insulation Sealant

5. White

6. Fire Stop

7. Gray HVAC Duct Mastic

8. Heating Water Insulation

9. Joint Compound

Building 7 - Samples Reported as Asbestos-Containing

ACM was not reported in the samples collected from Building 7. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.5 BUILDING 8, SERVICE ENTRY

Building 8 - Suspect Asbestos-Containing Materials

MECX identified the following HA within Building 8 and collected bulk samples of these materials for asbestos content.

1. Joint Compound

2. Metal HVAC Duct Seam Sealant

3. Roof Drain

Building 8 - Samples Reported as Asbestos-Containing ACM was not reported in the samples collected from Building 8. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.6 BUILDING 9, DOMICILE

Building 9 - Suspect Asbestos-Containing Materials

MECX identified the following HA within Building 9 and collected bulk samples of these materials for asbestos content.

1. Chilled Water Line Insulation Sealant

2. Ceiling Tile

3. Domestic Cold Water Insulation Sealant

4. Domestic Hot Water Insulation Sealant

5. Duct Insulation Sealant

6. Foil HVAC Duct Insulation Sealant

7. Red Fire Stop

8. Floor Tile Beige Vinyl 18" Striated

9. Floor Tile

10. Metal HVAC Duct Sealant

11. Hot Water Insulation Sealant

12. Joint Compound

13. Penetration Packing Pink

14. Steam Line Insulation Sealant

15. Blue Sheet Vinyl

16. Vinyl Flooring Wood Patterns

17. Wall Texture

Building 9 - Samples Reported as Asbestos-Containing

ACM was not reported in the samples collected from Building 9. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.7 BUILDING 10, CHAPEL

Building 10 - Suspect Asbestos-Containing Materials

MECX identified the following HA within Building 10 and collected bulk samples of these materials for asbestos content.

1. Joint Compound

2. Foiled HVAC Duct Insulation Sealant

3. Vinyl Flooring Wood Pattern

4. Ceiling Tile

3.7.2 Building 10 - Samples Reported as Asbestos-Containing

ACM was not reported in the samples collected from Building 10. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.8 BUILDING 11, COMMUNITY LIVING CENTER

Building 11 - Suspect Asbestos-Containing Materials MECX identified the following HA within Building 11 and collected bulk samples of these materials for asbestos content.

1. Vinyl Flooring Wood Pattern

2. Steam Line Insulation Sealant

3. Duct Insulation Sealant

4. Chilled Water Insulation Sealant

5. Hot Water Insulation Sealant

6. Ceiling Tile

7. Wall Plaster Finish

8. Floor Tile Beige Gray

9. Wall Plaster

10. Joint Compound

11. Foil Duct Insulation Sealant

Building 11 - Samples Reported as Asbestos-Containing ACM was not reported in the samples collected from Building 11. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

3.9 BUILDING 13, SIM LEARNING

Building 13 - Suspect Asbestos-Containing Materials

MECX identified the following HA within Building 13 and collected bulk samples of these materials for asbestos content.

1. Yellow Carpet Mastic

2. Ceiling Tile 2'x2' Smooth No Bevel

3. Duct Insulation Sealant

4. Beige HVAC Duct Seam Sealant

5. Expansion Tank Insulation Sealant

6. Foil HVAC Duct Insulation

7. Gray HVAC Duct Sealant

8. Hot Water Insulation Sealant

9. Joint Compound

10. Spray Applied Fire Proofing

11. Steam Line Insulation Sealant

12. Gray Mottled Sheet Vinyl Flooring

13. Vinyl Floor Wood Pattern

Building 13 - Samples Reported as Asbestos-Containing

ACM was not reported in the samples collected from Building 13. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

4.0 CONCLUSIONS AND RECOMMENDATIONS

MECX did not identify ACM during this survey.

This survey reports presents findings of observable and readily accessible materials assessed/sampled. This report does not guarantee that additional ACM is not present (i.e., concealed spaces).

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

5.0 LIMITATIONS

MECX warrants that the findings contained herein have been prepared with the level of skill exercised by experienced and knowledgeable environmental consultants who are appropriately licensed or otherwise trained to perform assessments pursuant to the scope of work required on this project.

The work that was performed during this investigation was done at the request of the VA and was non-destructive.

Materials may exist in inaccessible or hidden areas of the facility that were not observed or inspected during this investigation. Hidden materials may include, but are not limited to: TSI covered with metal jacketing, gasket material at pipe connections between flanges, vent pipe or duct insulation within wall cavities, vinyl floor tile or sheet flooring beneath sub-floors or overlays, spray-on acoustic texture hidden by door jams or covered with drywall.

The analytical results pertain to only the samples analyzed and may not reflect the actual composition of the entire homogeneous area. MECX assumes no responsibility for any subsequent use or interpretations of these analytical results. Prior to the removal of any asbestos containing materials, if any, a licensed abatement contractor should verify the quantities if removal is planned.

This report must not be used to claim product endorsement by NVLAP or any other state or federal government agency.

The quantification of the asbestos-containing materials are estimates made at the time of sampling. The quantities are estimates only and should be verified by the contractors bidding the project to determine exact square footage’s and the accessibility of the specific materials.

The opinions and conclusions presented here are based on field investigation, and observations made in the field, and are consistent with practices and actions of consulting professionals in the asbestos and industrial hygiene field.

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

APPENDIX A

Asbestos Summary Table

13 SEPTEMBER 2017

C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx

APPENDIX B

Laboratory Reports for Asbestos & Chain of Custody

Additional Constituents

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271793 JC-01 WHITE, POWDERY

NONHOM

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, POWDERY

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

L271794 JC-02 WHITE, POWDERY

HOMOGENEOUS

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

L271795 JC-03 WHITE, POWDERY

NONHOM

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, POWDERY

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, CHALKY

(SHEET ROCK)

NONE DETECTED 3% CELLULOSE

2% GLASS FIBERS

OTHER

L271796 JC-04 WHITE, POWDERY

NONHOM

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, CHALKY

(SHEET ROCK)

NONE DETECTED 3% CELLULOSE

2% GLASS FIBERS

OTHER

L271797 JC-05 WHITE, POWDERY

HOMOGENEOUS

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Laboratory Manager

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271798 JC-06 WHITE, POWDERY

HOMOGENEOUS

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

L271799 JC-07 WHITE, POWDERY

HOMOGENEOUS

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

L271800 JC-08 WHITE, POWDERY

NONHOM

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, CHALKY

(SHEET ROCK)

NONE DETECTED 3% CELLULOSE

2% GLASS FIBERS

OTHER

L271801 JC-09 WHITE, POWDERY

NONHOM

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, POWDERY

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, CHALKY

(SHEET ROCK)

NONE DETECTED 3% CELLULOSE

2% GLASS FIBERS

OTHER

L271802 JC-10 WHITE, POWDERY

NONHOM

(JOINT COMPOUND)

NONE DETECTED CALCITE, QUARTZ, MICA,

OTHER

WHITE, CHALKY

(SHEET ROCK)

NONE DETECTED 3% CELLULOSE

2% GLASS FIBERS

OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271803 WV2-01 WHITE, GUMMY

HOMOGENEOUS

(COVE BASE MASTIC)

NONE DETECTED OTHER

L271804 WV2-02 WHITE, GUMMY

HOMOGENEOUS

(COVE BASE MASTIC)

NONE DETECTED OTHER

L271805 WV2-03 WHITE, GUMMY

HOMOGENEOUS

(COVE BASE MASTIC)

NONE DETECTED OTHER

L271806 WV2-04 WHITE, GUMMY

HOMOGENEOUS

(COVE BASE MASTIC)

NONE DETECTED OTHER

L271807 FT1-01 PINK, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

WHITE, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271808 FT1-02 TAN, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

BEIGE, GUMMY

(MASTIC)

NONE DETECTED OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271809 FT1-03 BEIGE, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

YELLOW, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271810 FT1-04 BEIGE, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

YELLOW, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271811 FT1-05 BEIGE, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

YELLOW, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271812 FT1-06 BEIGE, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

YELLOW, GUMMY

(MASTIC)

NONE DETECTED OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271813 FT2-01 TAN, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

WHITE, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271814 FT2-02 PINK, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

WHITE, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271815 FT2-03 PINK, ELASTIC

NONHOM

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

WHITE, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271816 FT2-04 PINK, ELASTIC

HOMOGENEOUS

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

L271817 FT2-05 TAN, ELASTIC

HOMOGENEOUS

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

L271818 FT2-06 GRAY, ELASTIC

HOMOGENEOUS

(FLOOR TILE)

NONE DETECTED VINYL, OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271819 WV1-01 YELLOW, GUMMY

HOMOGENEOUS

(COVE BASE MASTIC)

NONE DETECTED CALCITE, OTHER

L271820 WV1-02 YELLOW, GUMMY

HOMOGENEOUS

(COVE BASE MASTIC)

NONE DETECTED CALCITE, OTHER

L271821 WV1-03 YELLOW, GUMMY

HOMOGENEOUS

(COVE BASE MASTIC)

NONE DETECTED CALCITE, OTHER

L271822 SV1-01 BLUE, ELASTIC

NONHOM

(SHEET VINYL)

NONE DETECTED VINYL, OTHER

CLEAR, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271823 SV1-02 BLUE, ELASTIC

NONHOM

(SHEET VINYL)

NONE DETECTED VINYL, OTHER

CLEAR, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271824 SV1-03 BLUE, ELASTIC

NONHOM

(SHEET VINYL)

NONE DETECTED VINYL, OTHER

CLEAR, GUMMY

(MASTIC)

NONE DETECTED OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271825 SV1-04 BLUE, ELASTIC

NONHOM

(SHEET VINYL)

NONE DETECTED VINYL, OTHER

CLEAR, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271826 SV1-05 GRAY, ELASTIC

HOMOGENEOUS

(SHEET VINYL)

NONE DETECTED 5% GLASS FIBERS

VINYL, OTHER

L271827 WF-01 BROWN, ELASTIC

HOMOGENEOUS

(VINYL FLOORING)

NONE DETECTED VINYL, OTHER

L271828 WF-02 BROWN, ELASTIC

HOMOGENEOUS

(VINYL FLOORING)

NONE DETECTED VINYL, OTHER

L271829 WF-03 BROWN, ELASTIC

HOMOGENEOUS

(VINYL FLOORING)

NONE DETECTED VINYL, OTHER

L271830 WF-04 BROWN, ELASTIC

HOMOGENEOUS

(VINYL FLOORING)

NONE DETECTED VINYL, OTHER

L271831 WF-05 BROWN, ELASTIC

HOMOGENEOUS

(VINYL FLOORING)

NONE DETECTED VINYL, OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271832 WF-06 BROWN, ELASTIC

NONHOM

(VINYL FLOORING)

NONE DETECTED VINYL, OTHER

CLEAR, GUMMY

(MASTIC)

NONE DETECTED OTHER

L271833 CT1-01 WHITE, FIBROUS

HOMOGENEOUS

(CEILING TILE)

NONE DETECTED 85% MINERAL WOOL

OTHER

L271834 CT1-02 WHITE, FIBROUS

HOMOGENEOUS

(CEILING TILE)

NONE DETECTED 85% MINERAL WOOL

OTHER

L271835 CT1-03 WHITE, FIBROUS

HOMOGENEOUS

(CEILING TILE)

NONE DETECTED 85% MINERAL WOOL

OTHER

L271836 CT1-04 WHITE, FIBROUS

HOMOGENEOUS

(CEILING TILE)

NONE DETECTED 85% MINERAL WOOL

OTHER

L271837 CT1-05 WHITE, FIBROUS

HOMOGENEOUS

(CEILING TILE)

NONE DETECTED 85% MINERAL WOOL

OTHER

L271838 CT1-06 WHITE, FIBROUS

HOMOGENEOUS

(CEILING TILE)

NONE DETECTED 85% MINERAL WOOL

OTHER

L271839 CT1-07 WHITE, FIBROUS

HOMOGENEOUS

(CEILING TILE)

NONE DETECTED 85% MINERAL WOOL

OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271840 SAFP-01 WHITE, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271841 SAFP-02 WHITE, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271842 SAFP-03 GREEN, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271843 SAFP-04 WHITE, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271844 SAFP-05 WHITE, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271845 SAFP-06 WHITE, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271846 SAFP-07 WHITE, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271847 SAFP-08 WHITE, FIBROUS

HOMOGENEOUS

(FIREPROOFING)

NONE DETECTED 45% CELLULOSE

CALCITE, VERMICULITE

L271848 RDS-01 WHITE, GUMMY

HOMOGENEOUS

(ROOF DRAIN

SEALANT)

NONE DETECTED 3% WOLLASTONITE

OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271849 RDS-02 WHITE, GUMMY

HOMOGENEOUS

(ROOF DRAIN

SEALANT)

NONE DETECTED 3% WOLLASTONITE

OTHER

L271850 RDS-03 WHITE, GUMMY

HOMOGENEOUS

(ROOF DRAIN

SEALANT)

NONE DETECTED 3% WOLLASTONITE

OTHER

L271851 GDM-01 GRAY, GUMMY

HOMOGENEOUS

(DUCT MASTIC)

NONE DETECTED 3% SYNTHETICS

CALCITE, OTHER

L271852 GDM-02 GRAY, GUMMY

HOMOGENEOUS

(DUCT MASTIC)

NONE DETECTED 3% SYNTHETICS

CALCITE, OTHER

L271853 GDM-03 GRAY, GUMMY

HOMOGENEOUS

(DUCT MASTIC)

NONE DETECTED 3% SYNTHETICS

CALCITE, OTHER

L271854 GDM-04 GRAY, GUMMY

HOMOGENEOUS

(DUCT MASTIC)

NONE DETECTED 3% SYNTHETICS

CALCITE, OTHER

L271855 FS-01 PINK, GUMMY

HOMOGENEOUS

(FIRESTOP)

NONE DETECTED 2% POLYETHYLENE

OTHER

L271856 FS-02 PINK, GUMMY

HOMOGENEOUS

(FIRESTOP)

NONE DETECTED 2% POLYETHYLENE

OTHER

L271857 FS-03 RED, GUMMY

HOMOGENEOUS

(FIRESTOP)

NONE DETECTED 2% GLASS FIBERS

OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271858 FS-04 PINK, GUMMY

HOMOGENEOUS

(FIRESTOP)

NONE DETECTED 2% POLYETHYLENE

OTHER

L271859 FS-05 PINK, GUMMY

HOMOGENEOUS

(FIRESTOP)

NONE DETECTED 2% POLYETHYLENE

OTHER

L271860 DIS-01 WHITE, GUMMY

HOMOGENEOUS

(DUCT INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271861 DIS-02 WHITE, GUMMY

HOMOGENEOUS

(DUCT INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271862 DIS-03 WHITE, GUMMY

HOMOGENEOUS

(DUCT INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271863 DIS-04 WHITE, GUMMY

HOMOGENEOUS

(DUCT INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271864 DIS-05 WHITE, GUMMY

HOMOGENEOUS

(DUCT INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271865 FDIS-01 WHITE, GUMMY

HOMOGENEOUS

(FOIL INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271866 FDIS-02 WHITE, GUMMY

HOMOGENEOUS

(FOIL INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271867 FDIS-03 WHITE, GUMMY

HOMOGENEOUS

(FOIL INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271868 FDIS-04 WHITE, GUMMY

HOMOGENEOUS

(FOIL INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271869 FDIS-05 WHITE, GUMMY

HOMOGENEOUS

(FOIL INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271870 FDIS-06 WHITE, GUMMY

HOMOGENEOUS

(FOIL INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271871 FDIS-07 WHITE, GUMMY

HOMOGENEOUS

(FOIL INSUL.

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271872 HWS-01 WHITE, GUMMY

HOMOGENEOUS

(HTG WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271873 HWS-02 WHITE, GUMMY

HOMOGENEOUS

(HTG WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271874 HWS-03 WHITE, GUMMY

HOMOGENEOUS

(HTG WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271875 HWS-04 WHITE, GUMMY

HOMOGENEOUS

(HTG WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271876 HWS-05 WHITE, GUMMY

HOMOGENEOUS

(HTG WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271877 HWS-06 WHITE, GUMMY

HOMOGENEOUS

(HTG WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271878 HWS-07 WHITE, GUMMY

HOMOGENEOUS

(HTG WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271879 CHWS

-01

WHITE, GUMMY

HOMOGENEOUS

(CH WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271880 CHWS

-02

WHITE, GUMMY

HOMOGENEOUS

(CH WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271881 CHWS

-03

WHITE, GUMMY

HOMOGENEOUS

(CH WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271882 CHWS

-04

WHITE, GUMMY

HOMOGENEOUS

(CH WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

5% GLASS FIBERS

OTHER

L271883 CHWS

-05

WHITE, GUMMY

HOMOGENEOUS

(CH WATER

SEALANT)

NONE DETECTED 5% WOLLASTONITE

5% GLASS FIBERS

OTHER

L271884 CHWS

-06

WHITE, CRUMBLY

HOMOGENEOUS

(CH WATER

SEALANT)

NONE DETECTED CALCITE, OTHER

*Asbestos-containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993.

Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Analysis results on this test report pertain only to those materials tested.

Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1% or none detected. This report may not be reproduced, except in full, without written approval by LES

Date Received: 07/31/2017 Date Analyzed: 08/01/2017

Lab Number

Field Number

Sample Description (Components)

Sample Location

Asbestos Detected

Loflin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006

(713) 521-3300 Fax (713)523-0829

Report of Bulk Sample Analysis For Asbestos Identification

Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994

Client: MECx, INC.

Client Address: 8864 INTERCHANGE DRIVE, HOUSTON, TX 77054 Project No: 750-17-02I Project Name: VA MEDICAL CENTER, ORLANDO; HOSPITAL

L271885 CHWS

-07

WHITE, CRUMBLY

HOMOGENEOUS

(CH WATER

SEALANT)

NONE DETECTED CALCITE, OTHER

L271886 ST-01 WHITE, GUMMY

HOMOGENEOUS

(STEAM SEALANT)

NONE DETECTED 5% WOLLASTONITE

OTHER

L271887 ST-02 WHITE, GUMMY

HOMOGENEOUS

(STEAM SEALANT)

NONE DETECTED 5% CELLULOSE

OTHER

L271888…

This is the start of the file's text. The full file is on GovTribe.