Atch 3 San Luis-Alamosa HQ REV 1 Replacement Pages Plans.pdf
PDF 1 MB Posted
- Attached to
- CO-SAN LUIS VALLEY COMPLEX HQ OFC BLDG Federal contract opportunity
- Solicitation number
- 140F0620R0025
About this file
This solicitation is for the construction of the San Luis Valley Complex HQ-Visitor Center building at Alamosa National Wildlife Refuge. Work includes construction of a 4,221 square foot facility to serve as the new headquarters for Alamosa NWR and other associated Fish and Wildlife Service functions in the San Luis Valley area. Additional work comprises construction of a parking lot, sidewalks, access road, a new domestic water supply well system and enclosure, liquid propane and garbage dumpster enclosures, and an exterior mounded leach field/septic system and electrical power supply system. The estimated value of the contract is between $1 million and $5 million. The solicitation will be offered as a total small business set-aside. The point of contact is the Contracting Officer Tim Officer at the Department of the Interior Fish and Wildlife Service.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Atch 9 FWS San Luis-Alamosa Welcome Center-HQ - Geotechnical Report_0002.pdf | ||
| Sol_140F0620R0025_Amd_0002.pdf | ||
| Sol_140F0620R0025_Amd_0001.pdf | ||
| Atch 1 San Luis-Alamosa HQ Specifications.pdf | ||
| Atch 2 San Luis-Alamosa HQ Plans.pdf | ||
| Atch 5 san Luis-Alamosa HQ Submittal Schedule.pdf | ||
| Atch 4 San Luis-Alamosa HQ Finish Board.pdf | ||
| Atch 8 San Luis Valley HQ Complex Bid Schedule.xlsx | XLSX spreadsheet | |
| Atch 7 San Luis Valley Alamosa HQ Past Perf Quest.doc | DOC document | |
| Sol_140F0620R0025.pdf | ||
| Atch 6 San Luis Valley Alamosa HQ DBA Wage Det.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET # SHEET NAME
C001 COVER
C002 CIVIL NOTES AND LEGEND
C101 HORIZONTAL CONTROL
C201 CIVIL SITE PLAN
C202 SITE DETAILS
C203 SITE DETAILS
C301 GRADING PLAN
C401 OVERALL UTILITY PLAN
C402 ENLARGED UTILITY PLAN
C403 WATER WELL DETAILS
C404 OWTS DESIGN REPORT
C405 OWTS SPECIFICATIONS
C406 OWTS DETAILS
C407 OWTS DETAILS
C501 EROSION CONTROL PLAN
C502 EROSION CONTROL NOTES
C503 EROSION CONTROL DETAILS
L101 LANDSCAPE PLAN - OVERALL
L201 LANDSCAPE PLAN - ENLARGEMENT
L301 LANDSCAPE DETAILS & NOTES
A001 ARCHITECTURAL NOTES
A100 ARCHITECTURAL SITE PLAN
A101 FIRST FLOOR PLAN
A102 FLOOR FINISH PLAN
A103 ROOF PLAN
A104 REFLECTED CEILING PLAN
A201 EXTERIOR ELEVATIONS
A202 EXTERIOR ELEVATIONS
A301 BUILDING SECTIONS
A401 ENLARGED PLANS
A402 ENLARGED PLANS/DETAILS/SIGNAGE
A501 ARCHITECTURAL DETAILS
A601 ARCHITECTURAL SCHEDULES
S101 STRUCTURAL GENERAL NOTES
S201 FOUNDATION PLAN
S202 ROOF FRAMING PLAN
S301 STRUCTURAL SECTIONS AND DETAILS
M001 MECHANICAL COVER
M002 MECHANICAL SCHEDULES
M003 MECHANICAL SCHEDULES
M101 FIRST FLOOR MECHANICAL HVAC PLAN
M102 FIRST FLOOR MECHANICAL PIPING PLAN
M103 FIRST FLOOR MECHANICAL ROOF PLAN
M104 MECHANICAL ZONE PLAN
M201 MECHANICAL SECTIONS AND ENLARGED PLANS
M301 MECHANICAL DETAILS
M302 MECHANICAL DETAILS
M303 MECHANICAL DETAILS
E001 ELECTRICAL COVER SHEET
E002 ELECTRICAL SCHEDULES
E101 FIRST FLOOR ELECTRICAL POWER AND SPECIAL SYSTEMS PLAN
E102 FIRST FLOOR ELECTRICAL LIGHTING PLAN
E301 ELECTRICAL DETAILS
ES101 ELECTRICAL SITE PLAN
P001 PLUMBING COVER
P101 FIRST FLOOR DOMESTIC WASTE AND VENT PIPE
P102 FIRST FLOOR DOMESTIC WATER AND GAS PLAN
P103 PLUMBING ROOF PLAN
P301 PLUMBING DETAILS
P302 PLUMBING DETAILS
N
I
C
H O
L
A
S
J
A
ME
S
W
E
S
T P
H
A
L
P
R
O
F
E
S
S
I
O
N
AL
E
N
G
I
N
E
E
R
49619
C
O
L
O
R
A
D
O L
I C
E
N
S
E
D
04/30/2020
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
3IN USFS BC 1963 (ELEV=7532.836)
AutoCAD SHX Text
IRON PIPE.. POSS SW S8 (ELEV=7532.313)
AutoCAD SHX Text
RC1 14840
AutoCAD SHX Text
CLIFF
AutoCAD SHX Text
SILVER
AutoCAD SHX Text
ALAMOSA
AutoCAD SHX Text
ANTONITO
AutoCAD SHX Text
LA JARA
AutoCAD SHX Text
ROMEO
AutoCAD SHX Text
CAPULIN
AutoCAD SHX Text
MONTE
AutoCAD SHX Text
VISTA
AutoCAD SHX Text
SANFORD
AutoCAD SHX Text
MANASSA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MOSCA
AutoCAD SHX Text
MOFFAT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ALAMOSA N.W.R.
AutoCAD SHX Text
HEADQUARTERS SITE
AutoCAD SHX Text
FORT
AutoCAD SHX Text
GARLAND
AutoCAD SHX Text
VIGIL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CITY
AutoCAD SHX Text
COLORADO
AutoCAD SHX Text
RED
AutoCAD SHX Text
WING
AutoCAD SHX Text
AutoCAD SHX Text
WALSENBURG
AutoCAD SHX Text
HOOKER
AutoCAD SHX Text
RC3 S1/4 S8 BLM 1981 (ELEV=7529.735)
AutoCAD SHX Text
RC1 14840 (ELEV 7530.328)
AutoCAD SHX Text
FISH AND WILDLIFE SERVICE
AutoCAD SHX Text
UNITED STATES DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
REGION 6 ENGINEERING - DENVER, COLORADO
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET 1 OF
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
VICINITY MAP
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
OR
AutoCAD SHX Text
RI
AutoCAD SHX Text
ME
AutoCAD SHX Text
RT
AutoCAD SHX Text
PA
AutoCAD SHX Text
DE
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text
NT
AutoCAD SHX Text
TE
AutoCAD SHX Text
IN
AutoCAD SHX Text E
AutoCAD SHX Text
TH
AutoCAD SHX Text
FISH AND WILDLIFE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text U.S.
AutoCAD SHX Text
U.S. FISH & WILDLIFE SERVICE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
FISH AND WILDLIFE
AutoCAD SHX Text
TH
AutoCAD SHX Text
ME
AutoCAD SHX Text
RT
AutoCAD SHX Text
PA
AutoCAD SHX Text
DE
AutoCAD SHX Text
NT
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text
OR
AutoCAD SHX Text
RI
AutoCAD SHX Text
TE
AutoCAD SHX Text
IN
AutoCAD SHX Text E
AutoCAD SHX Text U.S.
AutoCAD SHX Text
APPROVAL SIGNATURES
AutoCAD SHX Text
ANY PRINT ACCOMPANYING THIS INVITATION TO BID MAY BE A REDUCED
AutoCAD SHX Text
REPRODUCTION OF THE WORKING DRAWINGS. IF LINE BELOW DOES NOT
AutoCAD SHX Text
MEASURE SIX INCHES IN LENGTH, THE INDICATED SCALES ARE TO BE
AutoCAD SHX Text
ADJUSTED ACCORDINGLY.
AutoCAD SHX Text
%%UNOTE TO BIDDERS:%%
AutoCAD SHX Text
REGIONAL ENGINEER
AutoCAD SHX Text
ASS'T. REGIONAL DIR.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROGRAM SUPERVISOR
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
CULTURAL RESOURCES
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ALAMOSA
AutoCAD SHX Text
NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
ALAMOSA COUNTY
AutoCAD SHX Text
COLORADO
AutoCAD SHX Text
NEW OFFICE BUILDING
AutoCAD SHX Text
COVER
AutoCAD SHX Text
NW
AutoCAD SHX Text
KR
AutoCAD SHX Text
BD
AutoCAD SHX Text 2020.04.30
AutoCAD SHX Text
6R-CO-626-19-017
AutoCAD SHX Text
AutoCAD SHX Text
ALAMOSA NATIONAL WILDLIFE REFUGE
AutoCAD SHX Text
PROJECT NO. 19-017
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
EL RANCHO LANE
AutoCAD SHX Text
COUNTY ROAD 8 SOUTH
AutoCAD SHX Text
NEW REFUGE HEADQUARTERS
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
AutoCAD SHX Text 05-27-20
AutoCAD SHX Text
ADD ARSENIC FILTER SYSTEM
AutoCAD SHX Text
ACE
T
T
T
T
T
T
A A
B B
M201
GF
RZ
RZ
RZ
RZ
SS
CU
CU
M201
ET
OFFICE
CONFERENCE
EVIDENCE
STORAGE
OFFICE
ADMIN OFFICE
SERVER/ELECT
ROOM
VESTIBULE
MECHANICAL
BREAK ROOM
CORRIDOR
OPEN OFFICE
EXHIBITS
TOILET 2
TOILET 1
STAFF R.R.
AGF
3/4"ø CD
OFFICE
12 OFFICE
OFFICE
RECEPT
STORAGE
5/8"ø RS 3/8"ø RL
7/8"ø RS 3/8"ø RL
HWP
AS
1 1/2"ø HWR
1 1/2"ø HWS
B
3/4"ø HWS
3/4"ø HWR 3/4"ø HWS
3/4"ø HWR
/4 ø H
W S
/4 ø H
W S
3/4"ø HWR
1"ø HWR
1"ø HWS
SEE 1/M302 FOR
HYDRONIC PIPING SCHEMATIC
ACE JOB 19BL5047
2040 HARNISH BLVD.
BILLINGS, MT 59102
406-245-0136
DESIGNED DRAWN CHECKED DATE DRAWING NO. SHEET
SUB-SHEETALAMOSA NWR
DESCRIPTIONNO.
1 ARSENIC FILTER SYSTEM 05-27-20
6R-CO-626-19-017
NEW OFFICE BUILDING
FIRST FLOOR MECHANICAL PIPING PLAN
2020.04.30A.S.T.M. T.M.
M102
N
3/16" = 1'-0"M102
1 FIRST FLOOR MECHANICAL PIPING PLAN
MECHANICAL KEYNOTES
1 SEE 6/M301 FOR SPLIT SYSTEM REFRIGERANT PIPING DETAIL.
2 PROVIDE 3-WAY CONTROL VALVE MANIFOLD CONNECTION.
3 CONDENSING UNIT MOUNTED ON GRADE. PROVIDE 4" CONCRETE PAD BY G.C.
4 SEE 1/M303 FOR DX COIL CONNECTION DETAIL.
5 ELECTRIC HEAT FOR WELL HOUSE BY E.C.
6 SEE M104 FOR RADIANT ZONE PLAN. PROVIDE RADIANT FLOOR SLAB HEAT FROM
MANIFOLD TO SERVE ZONE IDENTIFIED.
7 3/4" CONDENSATE DRAIN FROM SS-1 TO FLOOR SINK. SEE PLUMBING DRAWINGS FOR
FLOOR SINK LOCATION.
8 TEMPERATURE CONTROLS PANEL. 120V BY E.C.
9 SEE 3/M301 FOR BOILER DETAIL.
MECHANICAL GENERAL NOTES
A MECHANICAL CONTRACTOR SHALL CUT ALL FLOORS, WALLS, CEILINGS, AND ROOF AS
REQUIRED TO PERFORM THE WORK DEPICTED IN THESE CONTRACT DOCUMENTS AND
SPECIFICATIONS. GENERAL CONTRACTOR SHALL PATCH ALL ASSOCIATED FLOORS,
WALLS, CEILINGS, AND ROOF AS REQUIRED TO THE SATISFACTION OF THE
ARCHITECT/ENGINEER.
B COORDINATE EXACT LOCATION OF DIFFUSERS AND GRILLES WITH REFLECTED CEILING
PLAN AND LIGHTING LAYOUT.
C FLEX DUCT RUN OUTS SHALL BE LIMITED TO 5'-0".
D COORDINATE HVAC AND PLUMBING EQUIPMENT WITH ALL OTHER TRADES AS
REQUIRED.
E DUCT PENETRATIONS THROUGH ROOF TO BE COORDINATED WITH JOIST LAYOUT.
F ALL DUCTS ABOVE CORRIDOR AREAS TO BE MINIMUM 24 GAUGE SHEET METAL.
G PROVIDE FLUSH CUP CONCEALED OPERATORS ON ALL HAND DAMPERS LOCATED ABOVE
HARD CEILINGS.
H LINE ALL SUPPLY AND RETURN DUCTS WITH 1" A.L. WITHIN 10' OF FURNACE/ERV.
I ALL DUCT DIMENSIONS SHOWN ON PLANS ARE CLEAR INTERIOR DIMENSIONS.
J MOUNT THERMOSTATS AT 48" A.F.F.
K VERIFY EXACT LOCATION OF T-STATS WITH ARCHITECT PRIOR TO INSTALLATION.
L PROVIDE VANES ON ALL DUCT ELBOWS GREATER THAN 30°.
M ALL SUPPLY, RETURN, AND EXHAUST DUCT TAKE-OFFS SHALL BE HIGH EFFICIENCY.
N SEAL ALL MECHANICAL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES WITH A UL
LISTED FIRE RATED SYSTEM.
O PROVIDE DUCT ACCESS DOORS FOR INSPECTING AND SERVICING ALL LOUVERS AND
MOTORIZED DAMPERS.
P ALL BRANCH DUCTS TO INDIVIDUAL SUPPLY/RETURN/EXHAUST GRILLES OR REGISTERS
TO BE PROVIDED WITH A MANUAL BALANCING DAMPER.
Q ALL VALVES SHALL BE BALL VALVES.
R LOCATE ALL VALVES ABOVE ACCESSIBLE CEILING SPACE OR PROVIDE ACCESS PANELS IN
CEILINGS FOR VALVE ACCESS. ACCESS PANELS SHALL BE RATED WHERE LOCATED IN A
RATED ASSEMBLY.
35604
P R O F
E S
S IO NA L EN
G
IN
E R
E
C
K
IP
A . WEED
A
O L
O
RA
DO LIC EN
S E D
2020.04.30
3 4
M201
GF
ERV
HWP
AS
ET
12"x10" x1
RZ
RZ
3/4"ø HWR
1"ø HWS
AGF
3"ø
3"ø
3/8"ø RL
7/8"ø RS
1 1/2"ø HWR1"ø HWR
1 1/2"ø HWS 1 1/2"ø HWS
L
14"x8" x8 x1
12"x10"
/4 ø H
W S
3/4"ø HWS
3/4"ø HWS
DL-1
B
ECONOMIZER FRESH
AIR INTAKE
FROM GRAVITY
VENTILATOR
EXHAUST
LOUVER
FURNACE
SUPPLY
FURNACE
RETURN
FRESH AIR
DUCT
EXHAUST
FROM
SPACE
FRESH AIR
TO ERV
FINISHED FLOOR
0' - 0"
CEILING
9' - 0"
MECHANICAL
EXHIBITS
GV
ERV
B
GF
3/8"ø RL
10"x12"
12"x12" 3"ø
16"x20"
8"ø8"ø
16"x16"
DL-2
RG-1
RG-1
EG-1
DL-1
18"x18" x2 x1
RZ
3/4"ø HWR
3/4"ø HWS
T.C. PANEL
AS
MOTORIZED
DAMPER
L
ET
FINISHED FLOOR
0' - 0"
CEILING
9' - 0"
A B
SOLAR TUBE
COLD ATTIC SPACE
MECHANICAL SOFFIT
DL-1
14"x14"
7"x10"
16"x16"
6"x6"
1"ø
3/4"ø
OFFICE
CORRIDOR
ADMIN OFFICE
GF
GV
20"x16"
18"x18"
20"x20"
20"x16"
12"x10"
12"x12" 20"x16"
ERV
ECONOMIZER MIXING BOX
GAS-FIRED
FURNACE
WALL MOUNTED
BOILER
MOTORIZED DAMPER
ACE JOB 19BL5047
2040 HARNISH BLVD.
BILLINGS, MT 59102
406-245-0136
DESIGNED DRAWN CHECKED DATE DRAWING NO. SHEET
SUB-SHEETALAMOSA NWR
DESCRIPTIONNO.
1 ARSENIC FILTER SYSTEM 05-27-20
6R-CO-626-19-017
NEW OFFICE BUILDING
MECHANICAL SECTIONS AND ENLARGED
PLANS
2020.04.30A.S.T.M. T.M.
M201
N
1/2" = 1'-0"M201
1 ENLARGED MECHANICAL ROOM PLAN
1/4" = 1'-0"M201
3 HVAC SECTION
1/4" = 1'-0"M201
4 HVAC SECTION
NOT TO SCALE
MECHANICAL ROOM HVAC ISOMETRIC
35604
P R O F
E S
S IO NA L EN
G
IN
E R
E
C
K
IP
A . WEED
A
O L
O
RA
DO LIC EN
S E D
PLUMBING SYMBOLS LEGEND
PIPING FITTINGS, VALVES & SPECIALTIES
DOMESTIC PIPING TYPES
GENERAL PIPING
MISCELLANEOUS/MECHANICAL PIPING TYPES
VTR
M
M or or or or or or or or or or or or
FT
P1P-1
GLOBE VALVE
3-WAY (ELECTRIC)
THIS IS A STANDARDIZED SYMBOLS LEGEND, ALL SYMBOLS SHOWN MAY
NOT APPEAR ON OR WITHIN THIS SET OF CONTRACT DOCUMENTS.
VENT THRU ROOF
STRAINER W/ BLOW-OFF
3-WAY (PNEU. MTR.)
3-WAY (PNEUMATIC)
PRESSURE GAUGE
TEMP. GAUGE
SENSOR (TEMP./FLOW)
FLEX. CONNECTION
SOLENOID GATE VALVE
WALL HYDRANT OR HOSE BIBB
FLOAT VALVE
BALANCING VALVE
DRAIN
PLUG VALVE
CHECK VALVE
STRAINER
PRESS. REDUCING
2-WAY (ELECTRIC)
2-WAY (PNEU. MTR.)
2-WAY (SOLENOID)
PNEUMATIC MOTOR
ANGLE VALVE
PLUMBING FIXTURE
FIXT. NUMBER - SEE SCHED.
GATE VALVE
BALL VALVE
CROSS IN HORIZ. RUN
90° AND 45° ELBOWS
END CAP CONNECTION
BELL AND SPIGOT UNION FITTING
BRANCH TEE TURNED UP
BRANCH TEE TURNED DN.
DIRECTION OF FLOW
ELBOW TURNED DN.
TEE TURNED DN.
DROP IN HORIZ. RUN
TEE TURNED UP
ELBOW TURNED UP
REDUCER FITTING
TEE IN HORIZ. RUN
BRANCH TEE W/ OFFSET
PUMP
FIRE EXTINGUISHER
FIRE SPRINKLER HEAD
DISCONNECTION
P.O.D.C. - POINT OF
P.O.C. - POINT OF
CONNECTION
DOMESTIC COLD WATER
DOMESTIC HOT WATER
CONDENSATE DRAIN
BUTTERFLY VALVE
SANITARY WASTE
VENT
LIQUID PETROLEUM GASLPG
CD
HW
CW
V
SAN
or STRAINER
ACE JOB 19BL5047
2040 HARNISH BLVD.
BILLINGS, MT 59102
406-245-0136
DESIGNED DRAWN CHECKED DATE DRAWING NO. SHEET
SUB-SHEETALAMOSA NWR
DESCRIPTIONNO.
1 ARSENIC FILTER SYSTEM 05-27-20
6R-CO-626-19-017
NEW OFFICE BUILDING
PLUMBING COVER
2020.04.30G.H.T.M. T.M.
P001
WC-1 WATER CLOSET AMERICAN STANDARD CADET #270AA.001 VITREOUS CHINA -- 1/2" -- 4" 2" --
12" ROUGH-IN. PROVIDE W/ BEMIS 1655SSCT HEAVY DUTY OPEN FRONT SEAT LESS
COVER.
S-1 SINLGE COMPARTMENT SINK ELKAY D12522-4 STAINLESS STEEL
AMERICAN STANDARD
MONTERREY #7501.170, WITH
R.O. FAUCET "KINGSTON"
MODEL KS3190
1/2" 1/2" 2" 2" X
PROVIDE SINK WITH 4 HOLE CONFIGURATION, CENTER DRAIN IN BOTH BOWLS,
ASSE 1070 COMPLIANT THERMOSTATIC MIXING VALVE, INSULATE HW, CW, &
STOPS AS REQ'D. INSTALL TO CONFORM TO ALL A.N.S.I. & A.D.A. REQUIRMENTS.
PROVIDE FAUCET WITH 1.5 GPM AERATOR, PROVIDE FAUCET WITH #372H WRIST
BLADE HANDLES.
MS-1 MOP SINK FIAT MSB 2424 MOLDED-STONE MOEN COMMERCIAL #8124 3/4" 3/4" 3" 2" --
SERVICE SINK FAUCET SHALL HAVE VACUUM BREAKER, CHECKS, SERVICE STOPS,
PAIL HOOK, TOP WALL BRACE & LEVER HANDLES, PROVIDE WITH FIAT HOSE &
BRACKET #832-AA, MOP HANGER #830AA & WALL GUARDS MSG2424
LAV-1 WALL MOUNTED LAVATORY AMERICAN STANDARD LUCERNE #0356.015 VITREOUS CHINA MOEN COMMERCIAL #9922 1/2" 1/2" 2" 2" X
PROVIDE ASSE 1070 COMPLIANT THERMOSTATIC MIXING VALVE, INSULATE HW,
CW, SAN, & STOPS. INSTALL TO CONFORM TO ALL A.N.S.I. & A.D.A.
REQUIRMENTS. PROVIDE FAUCET WITH 0.5 GPM AERATOR & COMMERCIAL CHAIR
TYPE CARRIERS FOR ALL LAVS.
HB-1 HOSE BIBB WOODFORD 67 CHROME "T" HANDLE KEY 3/4" -- -- -- -- FREEZELESS, BACKFLOW PROTECTED HOSE BIBB. SEE 2/P301.
FS-1 FLOOR SINK J.R. SMITH 3140Y-13 NICKEL BRONZE -- -- -- 3" 2" -- PROVIDE WITH TRAP PRIMER CONNECTION, 3/4 GRATE.
FD-1 FLOOR DRAIN SIOUX CHEIF 832-25D-NR-V DURA COATED CAST IRON BODY POLISHED NICKEL BRONZE TOP -- -- 2" 2" --
PROVIDE WITH SHIM KIT #832-S3, PROVIDE WITH TRAP PRIMER CONNECTION. SEE
1/P301 FOR DETAIL.
EWC-1 ELECTRIC WATER COOLER ELKAY EZS8WSLK STAINLESS STEEL BOTTLE FILLER EZWSR 1/2" -- 2" 2" --
WATER COOLER WITH BOTTLE FILLING STATION. MOUNT TO CONFORM TO ALL
A.N.S.I. & A.D.A. REQUIRMENTS.
CW HW SAN VENT
A.S.S.E.
1070 TMV
PLAN CODE ITEM MANUF. MODEL NUMBER MATERIAL & FINISH TRIM
ROUGH-IN SIZE
REMARKS
PLUMBING FIXTURE SCHEDULE
DWH-1 RINNAI RUR98I 199 183 92% 9.8 GPM LPG 120V/205W 18.3" X 10.1" X 31.2" SEE NOTES
PLAN CODE MANUF.
MODEL
NUMBER
MBH INPUT @ SEA
LEVEL
MBH OUTPUT @ SEA
LEVEL
THERMAL EFF.
MAXIMUM FLOW
RATE
FUEL SOURCE ELECTRICAL PHYSICAL SIZE REMARKS
DOMESTIC HOT WATER HEATER SCHEDULE
PET-1 WATTS PLT-5 5.0 2.1 1.26 40 5.5
PLAN CODE MANUF.
MODEL
NUMBER
SYSTEMS VOLUME
(GALS)
TOTAL VOLUME
(GALS)
ACCEPTABLE
VOLUME (GALS)
PRECHARGE
PRESSURE (PSIG)
WEIGHT (LBS)
POTABLE WATER EXPANSION TANK SCHEDULE
NOTES;
1. PROVIDE ALL FIXTURES WITH APPROPRIATE COMMERCIAL CARRIERS, CAST P-TRAPS, GRID STRAINERS, QUARTER TURN BALL STOPS AND MIXING VALVES FOR A COMPLETE INSTALLATION. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING
HEIGHTS.
2. VERIFY FLOOR FINISH THICKNESS BEFORE SETTING ANY FIXTURE.
3. ALL LAVATORIES AND SINKS TO BE PROVIDED WITH THERMOSTATIC MIXING VALVES TO TEMPER HOT WATER TO 110°F, MIXING VALVE SHALL CONFORM TO ASSE 1070.
4. PROVIDE FLUSH MOUNTED LOCKABLE ACCESS PANELS AS NEEDED FOR PLUMBING ACCESSORY ACCESS. COORDINATE LOCATION WITH ARCHITECT AND G.C. PRIOR TO ACCESSORY AND ACCESS DOOR INSTALLATION. REFER TO
ARCHITECTURAL SPECIFICATIONS FOR ACCESS DOOR REQUIREMENTS.
NOTES;
1. INTAKE AND VENTING SHALL BE OF THE SEALED-COMBUSTION DIRECT-VENT METHOD. FOLLOW MANUFACTURER'S INSTALLATION GUIDELINES.
2. PROVIDE AND INSTALL A GAS SHUT-OFF VALVE AND 6" DIRT LEG ON THE GAS LINE SERVING THE WATER HEATER, SEE 5/P301.
3. REFER TO DETAIL 4/P302 FOR ADDITIONAL INSTALLATION REQUIREMENTS.
4. PROVIDE WITH CONDENSATE NEUTRALIZER. INSTALL ON CONDENSATE DRAIN LINE FOR WATER HEATER (DWH-1).
5. WATER HEATER PROVIDED WITH INTEGRATED RECIRCULATION PUMP.
NOTES;
1. REFER TO DETAIL 4/P302 FOR EXPANSION TANK LOCATION.
2. EXPANSION TANK AND ALL ASSOCIATED COMPONENTS SHALL BE CERTIFIED
FOR POTABLE WATER USE.
PLUMING CONTRACTOR TO PROVIDE FIRE STOPPING OF ALL PLUMBING
PENETRATIONS THROUGH RATED WALLS
ALL FLOOR DRAINS AND FLOOR SINKS SHALL BE INSTALLED FLUSH WITH
THE FINISHED FLOOR. FLOOR SINKS SHALL BE UTILIZED AS INDIRECT
DRAINS AND AREA DRAINS.
ALL NEW PIPING, FITTINGS, VALVES AND FIXTURES FOR DOMESTIC
WATER SERVICE SHALL COMPLY WITH THE REDUCTION OF LEAD IN
DRINKING WATER ACT OF 2011 WHICH IS BEING ENFORCED AS OF 4
JANUARY 2014.
GENERAL PLUMBING NOTES
V.T.R VENT THROUGH ROOF TMV THERMOSTATIC MIXING VALVE
DWV
DOMESTIC WASTE &
VENT
H2O WATER
G.C. GENERAL CONTRACTOR # NUMBER
F.C.O. FLOOR CLEAN OUT W.C.O. WALL CLEAN OUT
DWG DRAWING W/ WITH
C.O.T.G. CLEAN OUT TO GRADE TYP TYPICAL
BFP BACKFLOW PREVENTER PLBG P.C. PLUMBING CONTRACTOR
BFF BELOW FINISHED FLOOR
MECH
M.C.
MECHANICAL
APPROX APPROXIMATE
MFG
MANUF
MANUFACTURER
AFF ABOVE FINISHED FLOOR M.C. MECHANICAL CONTRACTOR
PLUMBING ABBREVIATIONS
TOTAL -- 385 MBH
GF-1 GAS FURNACE 100 MBH
B-1 BOILER 85 MBH
DWH-1
DOMESTIC HOT
WATER HEATER
199 MBH
TAG DESCRIPTION
ITEM
INPUT DEMAND DEMAND UNITS
PROPANE FUEL LOAD SUMMARY
V-1 ALGAS TORREX TX25 1100 MBH 220 3.3 KW 1 19" x 19" x 54" SEE 7/P301
PLAN CODE MANUF. MODEL CAPACITY VOLT POWER PH SIZE (L X W X H) REMARKS
ELECTRIC PROPANE VAPORIZER
NOTES;
1. PROVIDE WITH VALVE AND STRAINER KIT, WALL MOUNTING KIT.
2. VAPORIZER TO BE DESIGNED FOR INSTALLATION ON OR NEAR PROPANE TANK, EXPLOSION PROOF ENCLOSURE.
RO-1
RO SYSTEMS
INTERNATIONAL
COM250S 4 275 GPD 40-80 PSI DOMESTIC DRINKING WATER
PROVIDE AND INSTALL ALL COMPONENTS FOR A COMPLETE AND OPERATIONAL SYSTEM PER THE
MANUFACTURER'S REQUIREMENTS. SYSTEM TO BE INSTALLED IN MECH #4, ROUTE R.O. LINE TO
BREAK ROOM #10, FAUCET TO BE INSTALLED IN THE 4th HOLE OF SINK S-1. PROVIDE RO-1 WITH
10" 5 MICRON SEDIMENT PRE-FILTER CARON FILTER. PROVIDE WITH 1/2 HP, 120V PUMP. UNIT TO
BE SKID MOUNTED FOR WALL MOUNTING.
PLAN CODE MANUF. MODEL NUMBER FILTRATION STAGES PRODUCTION VOLUME
FEED WATER
PRESSURE
SYSTEM NOTES
REVERSE OSMOSIS SYSTEM SCHEDULE
NOTES;
1. PROPANE DELIVERY PRESSURE 11" W.C.
2. DISTANCE TO MOST REMOTE FIXTURE APPROX. 30' FROM REGULATOR TO
DWH-1
P302 PLUMBING DETAILS
P301 PLUMBING DETAILS
P103 PLUMBING ROOF PLAN
P102 FIRST FLOOR DOMESTIC WATER AND GAS PLAN
P101 FIRST FLOOR DOMESTIC WASTE AND VENT PLAN
P001 PLUMBING COVER
PLUMBING SHEET LIST
35604
P R O F
E S
S IO NA L E
N G
IN
E R
E
C
K
IP
A . WEED
A
O L
O
RA
DO LIC EN
S E D
2020.04.30 WF-1,2 METSORB HMRG 1 7-12 GRAMS/KG HMRG 16”D x 65”H SEE WATER RISER DETAIL P302/3 FOR CONNECTION DETAIL
PLAN CODE MANUF. MODEL NUMBER FILTRATION STAGES ADSORPTIVE CAPACITY PHYSICAL SIZE NOTES
ARSENIC TREATMENT FILTER
NOTES;
1. FEATURING PATENTED NSF 61 VALIDATED TITANIUM DIOXIDE ADSORBENT MEDIA FOR THE EFFICIENT REDUCTION OF BOTH ARSENIC III & V. REMOVES LEAD, CADMIUM, COPPER, URANIUM, MERCURY AND OTHER HEAVY METALS
2. NON-HAZARDOUS DISPOSAL OF MEDIA AS SOLID WASTE - MEDIA PASSES EPA TCLP (TOXICITY CHARACTERISTIC LEACH PROCEDURE). HIGHER ADSORBENT CAPACITY THAN GFO (GRANULAR FERRIC OXIDE) & GFH (GRANULAR FERRIC HYDROXIDE)
3. NSF CERTIFIED FILTER TANK WITH ONE PIECE SEAMLESS POLYESTER CONSTRUCTION FOR LONG LIFE. HEAVY DUTY COMMERCIAL NSF CERTIFIED 1-1/2" AUTOMATIC BACKWASH CONTROL VALVE WITH BUILT-IN RELAYS AND CONTROL
4. TIME-TESTED, HYDRAULICALLY BALANCED PISTON SEAL AND SPACERS, PROVIDING YEARS OF SERVICE. NON-CORROSIVE HIGH-TECH MATERIAL CONSTRUCTION
5. USER FRIENDLY LCD DISPLAY, SHOWING TIME OF DAY, REGENERATION MODE, AND GALLONS REMAINING. PROPRIETARY LEGACY VIEW BLUETOOTH ENABLED 5900-BT ELECTRONIC CONTROL VALVE FOR ADVANCED WATER USAGE & FLOW MONITORING
6. PRECISE MONITORING OF WATER USAGE ALLOWS YOU TO CHANGE OUT ARSENIC MEDIA AFTER A PREDETERMINED NUMBER OF GALLONS HAS PASSED THROUGH SYSTEM!
7. LOW BACKWASH FLOW RATE, USES VERY LITTLE WASTE WATER COMPARED TO OTHER SYSTEMS. BACKWASH CAN BE SET FOR ONLY ONCE EVERY 2 WEEKS.
8. IF IRON OR MANGANESE IS PRESENT, REDUCE IRON TO LESS THAN 0.3 PPM AND REDUCE MANGANESE TO LESS THAN 0.04 PPM WITH A PRO-OX IRON FILTER SYSTEM.
A A
B B
P302
WC-1
WC-1
LAV-1
LAV-1EWC-1
LAV-1
S-1
WC-1
P302
DWH
P102
HB-1
HB-1
HB-1
RO SYSTEM
/4 ø C
W
3/4"ø CW
1"ø CW 3/4"ø HW
3/4"ø HW
/4 ø C
W
/4 ø C
W
1/2"ø CW
/2
"ø H
W
3/4"ø CW
"ø
C W
/2
"ø H
W
/2 ø C
W
3/4"ø HW 3/4"ø HW
1"ø CW
3/4"ø CW
"ø
L P G
3/4"ø HW
3/4"ø HW
1/2"ø HW
OFFICE
OFFICE
OFFICE
CONFERENCE
EVIDENCE
STORAGE
OFFICE
ADMIN OFFICE
SERVER/ELECT
ROOM
VESTIBULE
MECHANICAL
BREAK ROOM
CORRIDOR
OPEN OFFICE
EXHIBITS
TOILET 2
TOILET 1
STAFF R.R.
2 3
4 5
3/8"ø RO
3/8"ø RO 3/8"ø RO
3/4"ø LPG
1 1/2"ø CW
OFFICE
P302
GF
DWH
3/8"ø RO
3/4"ø CW
3/8"ø RO 1/2"ø CW
/4
"ø H
W
1 1/2"ø CW
"ø
C W
3/4"ø HW
3/4"ø HW
1"ø CW
/4
"ø H
W
/4
"ø L
P G
/4
"ø H
W
/4 ø C
W
1"ø LPG
1/2"ø LPG1/2"ø LPG
18 9
RO
"ø
L P G
ET
B
AGF
1/2"ø LPG
/2 ø C
W
SS
1 1/2"ø CW
1 1/2"ø CW
/2
"ø H
W
MS-1
3/8"ø RO
WF
WF
ACE JOB 19BL5047
2040 HARNISH BLVD.
BILLINGS, MT 59102
406-245-0136
DESIGNED DRAWN CHECKED DATE DRAWING NO. SHEET
SUB-SHEETALAMOSA NWR
DESCRIPTIONNO.
1 ARSENIC FILTER SYSTEM 05-27-20
6R-CO-626-19-017
NEW OFFICE BUILDING
FIRST FLOOR DOMESTIC WATER AND GAS
PLAN
2020.04.30G.H.T.M. T.M.
P102
N
3/16" = 1'-0"P102
1 FIRST FLOOR PLUMBING DOMESTIC WATER PLAN
PLUMBING GENERAL NOTES
A PLUMBING CONTRACTOR SHALL CUT ALL FLOORS, WALLS, CEILINGS, AND ROOF AS
REQUIRED TO PERFORM THE WORK DEPICTED IN THESE CONTRACT DOCUMENTS AND
SPECIFICATIONS. GENERAL CONTRACTOR SHALL PATCH ALL ASSOCIATED FLOORS,
WALLS, CEILINGS, AND ROOF AS REQUIRED TO THE SATISFACTION OF THE
ARCHITECT/ENGINEER.
B COORDINATE HVAC AND PLUMBING EQUIPMENT WITH ALL OTHER TRADES AS
REQUIRED.
C REFERENCE ARCHITECTURAL PLANS FOR EXACT FIXTURE LOCATIONS.
D ALL VALVES LESS THAN 2" SHALL BE BALL VALVES UNLESS OTHERWISE NOTED.
E COORDINATE UNDERSLAB PIPING WITH FOOTINGS AND STEM WALLS.
F INSULATION ON ALL DOMESTIC COLD WATER PIPING SHALL BE PROVIDED WITH A
CONTINUOUS VAPOR BARRIER. OVERSIZE HANGERS FOR INSULATION SO NO
PENETRATION OF THE VAPOR BARRIER OCCURS. PROVIDE INSERTS AND SADDLES AS
REQUIRED TO PREVENT INSULATION DAMAGE FROM SUPPORTS.
G NO DOMESTIC WATER PIPING SHALL BE ROUTED IN ANY EXTERIOR WALLS.
H PROVIDE ALL FLOOR DRAINS AND FLOOR SINKS WITH TRAP PRIMERS. PROVIDE WALL
ACCESS PANEL FOR TRAP PRIMER ACCESS AS REQUIRED. ACCESS PANELS SHALL BE RATED
WHERE REQUIRED.
I ALL UNDERFLOOR VENT SHALL BE MINIMUM 2".
J ALL UNDERFLOOR COPPER SHALL BE TYPE "K" SEAMLESS OR PEX.
K PROVIDE CLEANOUTS ON ALL LINES SERVING SINKS AND URINALS, SEE 4/P301.
PLUMBING KEYNOTES
1 ROUTE 3/4” CW/HW DOWN TO SERVE MOP SINK.
2 ROUTE 1/2” CW/HW DOWN TO SERVE BACK-TO-BACK LAVATORIES.
3 ROUTE 3/4” CW DOWN TO SERVE HOSE BIBB, INSTALL SHUT-OFF VALVE IN AN
ACCESSIBLE LOCATION.
4 ROUTE 1/2” CW/HW DOWN TO SERVE SINK/LAVATORY.
5 ROUTE 1/2” CW DOWN TO SERVE WATER CLOSET.
6 ROUTE 1/2” CW DOWN TO SERVE ELECTRIC WATER COOLER
7 ROUTE 1/2” CW DOWN TO SERVE BACK-TO-BACK WATER CLOSETS.
8 ROUTE 3/4” LPG DOWN TO SERVE DOMESTIC WATER HEATER, 4/P302 FOR CONNECTION
DETAIL.
9 ROUTE 3/4” CW/HW DOWN TO SERVE DOMESTIC WATER HEATER, 4/P302 FOR
CONNECTION DETAIL.
10 ROUTE 1/2” LPG TO SERVE MECHANICAL EQUIPMENT, SEE 5/P301. FOR CONNECTION
DETAIL.
11 ROUTE 1/2” LPG DOWN TO SERVE BOILER, SEE 5/P301 FOR CONNECTION DETAIL.
12 RO SYSTEM TO BE ELEVATED ABOVE MOP SINK MS-1 ON CONTRACTOR PROVIDED SHELF
7’ FROM FLOOR.
13 ROUTE 1 1/2” CW TO BUILDING FOR WATER SERVICE. SEE CIVIL SITE PLAN FOR WATER
MAIN SIZES AND COUNTINUATION. WATER SERVICE TO BE INSTALLED 72” BELOW
FINISHED GRADE.
14 ROUTE 10 PSI LPG SERVICE FROM TANK UP TO 10 PSI TO 11” W.C. PRV, THEN ROUTE
INTO BUILDING, SEE DETAIL 7/P301. SEE CIVIL SITE PLAN FOR LPG CONTINUATION.
15 DOMESTIC WATER RISER, SEE 3/P302.
16 ROUTE 3/4” HOT WATER “LOOP” OUT TO FIXTURES AND BACK TO WATER HEATER.
17 ROUTE 3/8” RO LINE DOWN TO RO FAUCET AT S-1.
18 CONTRACTOR PROVIDED 12”X12” PLUMBING ACCESS PANEL, SEE ARCHITECTURAL PLANS
FOR DETAILS.
NOT TO SCALE
ENLARGED MECHANICAL ROOM
35604
P R O F
E S
S IO NA L E
N G
IN
E R
E
C
K
IP
A . WEED
A
O L
O
RA
DO LIC EN
S E D
2020.04.30
NOTES:
1) SEAL ALL PENETRATIONS AND CRACKS/JOINTS IN CONCRETE FLOOR WITH
POLYURETHANE (NO SILICONE CAULKS) SEALANT/CAULK. THIS SHALL INCLUDE
SEWER PIPE, CONDUIT, AND OTHER PENETRATIONS INCLUDING SLAB JOINTS,
POUR JOINTS, FLOOR/WALL JOINTS, ETC. USE BACKER ROD WHEN APPLYING
CAULK IN LARGE CRACKS.
2) PROVIDE 4 - 6 INCHES OF ASTM SIZE #5 AGGREGATE OR EQUIVALENT UNDER
ENTIRE SLAB.
3) INSTALL SYSTEM PER DETAILS ON THIS SHEET.
4) REFERENCE EPA "RADON PREVENTION IN THE DESIGN OF CONSTRUCTION OF
SCHOOLS AND OTHER LARGE BUILDINGS" DOCUMENT DATED 6/1994.
NOTE:
GEOTEXTILE FABRIC IS TO PREVENT FINE PARTICLES
MIXING WITH AGGREGATE AND VAPOR RETARDER
TO PREVENT WET CONCRETE FROM FILLING LAYER.
EF
14'-0"
8"
FOR FLOOR SLAB OVER RADON PIT: COORDINATE
LOCATION/SIZE OR REBAR W/ STRUCTURAL
ENGINEER AND GENERAL CONTRACTOR
1 1/2" x 18 GA. TYPE B
GALVANIZED METAL DECK
THICKENED CONCRETE SLAB
CONCRETE SLAB
STACK VENTED
THROUGH ROOF
SEALANT
4" SUCTION PIPE
PIPE SLEEVE (OPTIONAL)
4" MINIMUM CLEAN COARSE AGGREGATE
ASTM SIZE #5 OR EQUIVALENT UNDER ENTIRE
BUILDING
GEOTEXTILE FABRIC, BY G.C.
POURED CONCRETE BASE (4")
EXPANDED METAL ON ALL 4 SIDES
WELDED TO ANGLE SUPPORTS
ANGLE 2x2x1/4" VERTICAL
AT EACH CORNER
ANGLE 2x2x1/4" CONT. T&B
AROUND PERIMETER OF PIT
ANGLE 2x2x1/4" AROUND
PERIMETER TOP/BOTTOM
1 1/2" x 18 GA. TYPE B
GALVANIZED METAL DECK
ANGLE 2x2x1/4" CONT. T&B
AROUND PERIMETER OF PIT
ACTIVE SOIL
DEPRESSURIZATION
SYSTEM
ROOF
FLASH WEATHER TIGHT
4" SCHEDULE
40 PVC
POSITIVE
PRESSURE IN
SPACE
POLYURETHANE
CAULK
NEGATIVE PRESSURE
RADON SUCTION PIT
VAPOR RETARDER, BY G.C.
POLYURETHANE
CAULK
SYSTEM SCHEMATICRADON SUCTION PIT CONSTRUCTION
Level 1
0' - 0"
PET-1
MS-1
CHECK VALVE
BALL
VALVE
TYP.
DOMESTIC WATER
HEATER
POTABLE
WATER
EXPANSION
TANK
DRAIN VALVE
CONDENSATE
NEUTRALIZER
THERMOMETER
3/4"ø HW 3/4"ø LPG
3/4"ø HW
3/4"ø CW
3/4"ø CD
1/2"ø CD
DIRT LEG
3/8"ø CD
UBBIMK
POLYPROPYLENE
CONCENTRIC
VENT
DWH
RO
SHUT-OFF BALL
VALVE, TYP.
STRAINER
1 1/2" CW
TO SYSTEM
WF
WF
FS-1
UNION, TYP.
RADON SUCTION PIT
DWH
RO
4"ø SAN
4"ø V
COORD. SEWER ELEVATION TO
BE BELOW RADON SUCTION PIT.
FS-1
FD-1
FS-1
MS-1
Level 1
0' - 0"
Roof
9' - 0"
A B
3/8"ø RO
1"ø CW
3/4"ø HW 3/4"ø HW
16"x16"
14"x14"
4"ø SAN
6"x6"
CONFERENCE
CORRIDOR
OFFICE
SOLAR TUBE
ACE JOB 19BL5047
2040 HARNISH BLVD.
BILLINGS, MT 59102
406-245-0136
DESIGNED DRAWN CHECKED DATE DRAWING NO. SHEET
SUB-SHEETALAMOSA NWR
DESCRIPTIONNO.
1 ARSENIC FILTER SYSTEM 05-27-20
6R-CO-626-19-017
NEW OFFICE BUILDING
PLUMBING DETAILS
2020.04.30G.H.T.M. T.M.
P302
NOT TO SCALE
RADON COLLECTION SYSTEM DETAIL
NOT TO SCALE
DWH - PIPING DETAIL SECTION
NOT TO SCALE
DOMESTIC WATER RISER
NOT TO SCALE
MECHANICAL ROOM - ISOMETRIC
NOT TO SCALE
LATERAL SECTION
35604
P R O F
E S
S IO NA L E
N G
IN
E R
E
C
K
IP
A . WEED
A
O L
O
RA
DO LIC EN
S E D
File details come from the government source that posted it. Updated .