About this file

This document is a Lead-Based Paint (LBP) Inventory Report for Facility Number 4, an Aircraft Maintenance facility located at JBSA Randolph. The report comprehensively documents multiple work orders from 2011-2013 revealing lead-based paint presence in various areas including hangar doors, concrete walls, I-beams, and interior spaces like breakrooms and offices.

The report emphasizes strict OSHA 29 CFR 1926.62 compliance requirements, mandating that any paint disturbance (sanding, grinding, blasting, drilling, welding) must be performed exclusively by a certified lead abatement team. A subsequent 2025 entry confirms ongoing lead-based paint monitoring, specifically noting gray I-beams at the facility are positive for lead-based paint, with a work order (WT# 1508471) for installing two 5-ton hoists requiring certified lead abatement procedures. The facility is owned by 12 MSG/CE, has a manned status, and contains one floor with zero recorded square footage.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JBSA LBP Inventory Print Report

Lead Based Paint Detected:

Acft Maintenance

Square Footage: 0

Number of Floors: 1

None.dwg

Drawing File Name:

Facility Status: Manned

4.jpg Photo File Name

Date Constructed: 0

Facility Number: Facility Name:4 ACFT MAINTENANCE

Facility Owner: 12 MSG/CE

Facility Type:

Facility Address: BASE

Facility Summary Report:

A=North, B=East, C=South, D=West

05/16/2013 - Work order 11273 - Inspect Hangar Doors for Safety and operational purposes - All Hangar 4 Doors are positive for LBP. If paint is to be disturbed, it must be done by a certified lead firm. This includes sanding, grinding, blasting, paint removal welding operations and any other disturbance by physical or mechanical means.

4/29/2013 - Workorder 11267 - install 400 Volt, 115 Hz to power six T-38 aircraft at 6 different spots - All concrete walls are Positive for LBP at OSHA levels of any amount. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project.

All work must be done by a Lead Certified Firm. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater. A negative determination will be required for this project by a certified Lead Firm before anyone other than a Lead certified worker can disturb the existing paint by any chemical or abrasive means.

06/12/2012 - workorder 10934 - Renovate Breakroom and Offices - The breakroom mini blinds and the Post Dock Door Casing is positive for LBP. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater.

08/15/2011, WO#10498 - Paint hangar Doors inside and Out - Exterior and Interior Hangar Doors are Positive for LBP. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. The OSHA requirement for these rules applies for any amount of LBP.

8/1/11, WO# 10449 Upgrade NIPERNET, Concrete walls in hangar are positive for LBP. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR

1926.62 rules will apply for this project. The OSHA requirement for these rules applies for any amount of LBP.

Facility Site: JBSA Randolph

ViewFacility Comments:

Facility Comments:

LBP Report File Name(s):

2013-05-15_11267_Converters.p

602 4/2/2025 0.5Hanger N/A Top I-Beam Metal Gray Intact Positiv

603 4/2/2025 0.6Hanger N/A Top I-Beam Metal Gray Intact Positiv

Date User Comment

4/3/2025 JJP WT# 1508471 Install two 5 ton hoist. Gray I-beams are positive for lead-based paint. Any disturbance to these materials needs to be performed by a certified lead abatement team.