Atch 1 - Salient Characteristics_VM Compressor_final.pdf

PDF 192 KB Posted

Attached to
Vehicle Maintenance Air Compressor Federal contract opportunity
Solicitation number
W50S6W25Q0008
Issued by
Department of the Army National Guard

About this file

The document is a Salient Characteristics specification for a Vehicle Maintenance Air Compressor system for the Department of the Army National Guard. The system requirements include a rotary screw air compressor with a flow rate of 75 cfm at 160 psig, 20 hp drive motor, 92-gallon compressed air receiver, and specific electrical and dimensional specifications. Additional requirements cover an air filter, vertical accessory tank, and comprehensive installation work involving removing existing iron airline and replacing it with non-corrosive aluminum airline throughout Building 3217.

Installation details specify the deployment of 7 hose reels, manifolds for various work areas, and specific configurations for the main VM bay, tire shop, and refueling bay. The system must include training, be installed and certified by a technician prior to training, and include system shipment to the receiving location. The document includes a Commercial Availability Certification, indicating that all specified characteristics are available in the commercial marketplace, and is part of Solicitation Number W50S6W25Q0008 for a Vehicle Maintenance Air Compressor, with a site visit scheduled for 6 August 2025.

View the file

Other files for this federal contract opportunity

Other files attached to Vehicle Maintenance Air Compressor, newest first.
File Type Posted
W50S6W25Q0008 Questions and Answers 15 Aug 25.docx DOCX document
3217 SEPT09 LAYOUT.pdf PDF
3217 Floor Plan with Equipment Locations.pdf PDF
3217 SEPT09 POWER.pdf PDF
Air Compressor RFQ_22 Jul 25.docx DOCX document
Atch 2 - Statement of Work Air Compressor_final.docx DOCX document
Air Compressor RFQ_22 Jul 25.docx DOCX document
Atch 3 - Visitor Information_blank.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

The air compressor system must meet the minimum criteria below:

• Air Compressor

▪ Rotary screw compressor

▪ Flow rate 75 cfm or greater at 160 psig

▪ Drive motor rated capacity at 20.0 hp or greater

▪ Sound pressure level 70 dB(A) or lower

▪ Underslung compressed air receiver 92 gallons or larger

▪ Electrical Supply 208/230/460V / 3 / 60Hz

▪ Must be enclosed in a single housing

▪ Dimensions of 36in W X 60in D X 96in H or smaller

▪ Automatic condensation drain

▪ Control cabinet must be dust and water-resistant

• Air Filter

▪ Flow rate of 75 CFM or higher

▪ Operating Pressure of 230 psig / 30 psig or better

▪ Automatic condensation drain

▪ Dimensions 10in W X 10in D X 20 in H or smaller

▪ Differential pressure gauge

• Vertical Accessory Tank

▪ Contain 240 gallons or greater

▪ Vertical configuration

▪ Sustain 200 PSI or greater

• Installation Items

▪ Use of non-corrosive “Smart Pipe +” for all hard mounted plumbing

▪ Installation of 7 hose reels 100ft long or longer

▪ Provide manifolds to all work areas not accessible with hose reels

▪ Leak test

▪ Scissor lift rental

• Installation Work (See Statement of Work)

▪ Installation must include removal of existing iron airline and replacement with non-corrosive aluminum airline throughout building 3217. Existing non-corrosive copper lines can be reused as needed.

▪ Branches to be ¾”

▪ Main VM bay to have a total of (4) above head mounted hose reels

▪ Add one dedicated drop/line for 4 post lift in the main VM bay

▪ Add manifold for tire shop to include hardline for reel and (2) two port manifolds. Install 1 hose reel on wall above hard point.

▪ Demo existing iron line in Refueling Bay and replace with two hose reels suspended from ceiling

▪ Branch lines to be ¾” (Refueling Bay)

▪ Refueling Bay will receive (2) hose reels, one on each side of vehicles as positioned in the bay

▪ Provide training

▪ System must be installed/started by installing technician and certified at location prior to training

▪ Shipment of system to receiving location must be included

Commercial Availability Certification:

I have evaluated the commercial marketplace and determined that all the salient characteristics documented below are available in products/services offered in the commercial marketplace.

Signature Technical Point of Contact Or Contracting Officer Representative (COR):

X

Technical Point of Contact (TPOC)

Contracting Officer:

X

Contracting Officer (KO)

2025-07-22T11:12:16-0400
IM.BO.SUN.1363746299

File details come from the government source that posted it. Updated .