ASHE 20-1063_PH-2_CCEB_REV02 MDT.xlsx

XLSX spreadsheet 76 KB Posted

Attached to
ASHE 20-1063 RPR MEDIUM VOLTAGE SUBSTATIONS MULTI, PHASE II Federal contract opportunity
Solicitation number
FA568221R0009
Issued by
Department of the Air Force United States Air Forces in Europe - Air Forces Africa

About this file

This document is a pre-solicitation notice for project ASHE 20-1063 to repair medium voltage substations at Aviano Air Base in Italy, Phase 2 - Revision 2. The work includes replacement of protection relays, batteries, battery chargers, and other electrical components across various substations. The estimated value of construction is between $500,000 to $1,000,000. Offerors must have a current System for Award Management registration and Special Occupational Authorization certification in category OG11 at time of proposal submission and award. The performance will require completion of the project on a lump sum basis. The solicitation is expected to be issued in June 2021.

View the file

Other files for this federal contract opportunity

Other files attached to ASHE 20-1063 RPR MEDIUM VOLTAGE SUBSTATIONS MULTI, PHASE II, newest first.
File Type Posted
Solicitation - FA568221R0009.pdf PDF
2009_31st_RPR_MV_SUBS_PSC.pdf PDF
ASHE 20-1063_PH-2_TECH-SPECS_REV02.pdf PDF
ASHE 20-1063_PH-2_Rev1_DRAWINGS.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASHE 20-1063 , PHASE 2

GOVERNMENT COST ESTIMATE BREAKDOWN
CONTRACTORADDRESS
CONTRACT FOR (Work to be performed)PROPOSED TOTAL CONTRACT PRICE
RPR MEDIUM VOLTAGE SUBSTATIONS, MULTI (DSN) - AVIANO A.B., ITALY
PURCHASE REQUEST NUMBERPROJECT NUMBERWORK LOCATION
ASHE 20-1063 (PHASE 2 - Rev#2)ALL AREAS, AVIANO AIR BASE, ITALY
MATERIAL COSTSLABOR COSTS
LINE NO.ITEMUNIT OF MEASUREQUANTITYUNITTOTALMANHOURS MANDAYSAVERAGE RATETOTALOTHER DIRECT COSTSLINE TOTAL
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
A.REPAIR WORKS / Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni
Ie Electrical Demolition - Ia Demolizioni Impianti Elettrici
1REMOVAL AND DISPOSAL OF THE 20 kV PROTECTION RELAY
Rimozione e smaltimento di relè di protezione 20 kVIT. No. Art. n.1.01LS/AC
1REMOVAL AND DISPOSAL OF EMERGENCY RECTIFIER 230Vac / 24Vdc, WITH LEAD ACID BATTERIES
Rimozione e smaltimento di raddrizzatore di emergenza 230Vac / 24Vcc, con batterie al piombo acidoIT. No. Art. n.2.01Ea/No
2REMOVAL AND DISPOSAL OF Ni-Cd BATTERY PACKAGE, SUB F37
Rimozione e smaltimento di batterie Ni-Cd, cabina F37IT. No. Art. n.2.02Ea/No
Total Electrical Demolitions - Totale Demolizioni Elettriche

TOTAL PART I / Totale Parte I

PART IV - ELECTRICAL WORK / Parte IV - Lavori Elettrici
REPLACEMENT OF 20 kV RELAYS
REPLACEMENT OF THE EXISTING OUT-OF-SERVICE RELAYS LOCATED ON THE 20 KV SWITCHBOARDS OF THE AVIANO A.B. SUBSTATIONS. THE REPLACEMENT INCLUDES FURNISHING AND INSTALLATION OF EACH DEVICE AND ITS ASSOCIATED AUXILIARY COMPONENTS, MODULES, CARDS, WIRING CONNECTION, THRESHOLDS SETTINGS, INSTRUMENTAL TESTS, COMMISSIONING, TO GUARANTEE THE FULLY RESTAURATION OF THE PROTECTION.
Sostituzione dei relè fuori-servizio dei quadri 20 kV nelle cabine della Base Aerea di Aviano. La sostituzione include la fornitura e la sostituzione di ogni dispositivo e relativi componenti associati, moduli, schede, cablaggi, tarature, test strumentali, messa in servizio, per garantire il completo ristoro delle protezioni.3
AREA "F"
3SUBSTATION F2 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F2 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.01EA/NO
4SUBSTATION F2 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F2 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.02EA/NO
5SUBSTATION F4A - REPLACEMENT RELAY S.E. model SEPAM 20 type S20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F4A - Sostituzione relè S.E. modello SEPAM 20 tipo S20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.03EA/NO
6SUBSTATION F4A - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F4A - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.04EA/NO
7SUBSTATION F6 - REPLACEMENT RELAY S.E. model SEPAM 20 type S20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F6 - Sostituzione relè S.E. modello SEPAM 20 tipo S20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.05EA/NO
8SUBSTATION F6 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F6 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.06EA/NO
9SUBSTATION F7 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F7 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.07EA/NO
10SUBSTATION F7 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F7 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.08EA/NO
11SUBSTATION F8 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F8 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.09EA/NO
12SUBSTATION F8 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F8 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.10EA/NO
13SUBSTATION F9 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F9 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.11EA/NO
14SUBSTATION F9 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F9 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.12EA/NO
15SUBSTATION F10 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F10 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.13EA/NO
16SUBSTATION F10 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F10 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.14EA/NO
17SUBSTATION F11 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F11 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.15EA/NO
18SUBSTATION F12 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F12 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.16EA/NO
19SUBSTATION F12 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F12 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.17EA/NO
20SUBSTATION F12A - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F12A - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.18EA/NO
21SUBSTATION F12A - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F12A - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.19EA/NO
22SUBSTATION F13 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F13 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.20EA/NO
23SUBSTATION F13 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F13 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.21EA/NO
24SUBSTATION F14 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F14 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.22EA/NO
25SUBSTATION F14 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F14 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.23EA/NO
26SUBSTATION F15 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F15 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.24EA/NO
27SUBSTATION F15 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F15 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.25EA/NO
28SUBSTATION F16 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F16 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.26EA/NO
29SUBSTATION F16 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F16 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.27EA/NO
30SUBSTATION F17 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F17 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.28EA/NO
31SUBSTATION F17 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F17 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.29EA/NO
32SUBSTATION F18 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F18 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.30EA/NO
33SUBSTATION F18 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F18 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.31EA/NO
34SUBSTATION F19 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F19 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.32EA/NO
35SUBSTATION F19 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F19 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.33EA/NO
36SUBSTATION F20 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F20 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.34EA/NO
37SUBSTATION F20 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F20 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.35EA/NO
38SUBSTATION F21 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F21 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.36EA/NO
39SUBSTATION F21 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F21 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.37EA/NO
40SUBSTATION F22 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F22 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.38EA/NO
41SUBSTATION F22 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F22 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.39EA/NO
42SUBSTATION F23 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F23 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.40EA/NO
43SUBSTATION F23 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F23 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.41EA/NO
44SUBSTATION F24 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F24 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.42EA/NO
45SUBSTATION F24 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F24 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.43EA/NO
46SUBSTATION F24A - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F24A - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.44EA/NO
47SUBSTATION F24A - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F24A - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.45EA/NO
48SUBSTATION F25 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F25 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.46EA/NO
49SUBSTATION F25 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F25 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.47EA/NO
50SUBSTATION F26 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F26 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.48EA/NO
51SUBSTATION F26 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F26 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.49EA/NO
52SUBSTATION F27 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F27 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.50EA/NO
53SUBSTATION F27 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F27 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.51EA/NO
54SUBSTATION F28 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F28 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.52EA/NO
55SUBSTATION F28 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F28 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.53EA/NO
56SUBSTATION F29 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F29 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.54EA/NO
57SUBSTATION F29 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F29 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.55EA/NO
58SUBSTATION F31 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F31 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.56EA/NO
59SUBSTATION F31 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F31 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.57EA/NO
60SUBSTATION F32 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F32 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.58EA/NO
61SUBSTATION F32 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F32 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.59EA/NO
62SUBSTATION F33 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F33 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.60EA/NO
63SUBSTATION F33 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F33 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.61EA/NO
64SUBSTATION F35 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F35 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.62EA/NO
65SUBSTATION F35 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F35 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.63EA/NO
66SUBSTATION F38 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F38 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.64EA/NO
67SUBSTATION F39 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F39 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.65EA/NO
68SUBSTATION F39 - REPLACEMENT RELAY S.E. model SEPAM 20 type S20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F39 - Sostituzione relè S.E. modello SEPAM 20 tipo S20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.66EA/NO
69SUBSTATION F39 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F39 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.67EA/NO
70SUBSTATION F42 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F42 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.68EA/NO
71SUBSTATION F42 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica F42 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.69EA/NO
AREA "A1"
72SUBSTATION 151 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 151 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.70EA/NO
73SUBSTATION 151 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 151 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.71EA/NO
74SUBSTATION 177 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 177 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.72EA/NO
AREA "A2"
72SUBSTATION 246 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 246 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.73EA/NO
73SUBSTATION 246 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 246 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.74EA/NO
AREA "C"
74SUBSTATION 420 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 420 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.75EA/NO
75SUBSTATION 420 - REPLACEMENT RELAY S.E. model SEPAM 20 type T20 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 420 - Sostituzione relè S.E. modello SEPAM 20 tipo T20 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.76EA/NO
AREA "E"
76SUBSTATION 604 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 604 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.77EA/NO
AREA "G"
77SUBSTATION 15703 - REPLACEMENT RELAY S.E. model SEPAM 40 type S42 e I/O module MES 114. Thresholds settings, instrumental test, commissioning.
Cabina elettrica 15703 - Sostituzione relè S.E. modello SEPAM 40 tipo S42 e modulo I/O MES 114. Impostazione soglie, test strumentale, messa in servizio.IT. No. Art. n.3.78EA/NO
SPARE
78SPARE RELAY - FURNISHING OF A SEPAM 40 type S42 RELAY AND DELIVER TO THE AVIANO A.B. PERSONNEL.
Rele' di riserva - Fornitura di un relè S.E. modello SEPAM 40 tipo S42 e consegna al personale della Base Aerea di Aviano.IT. No. Art. n.3.79EA/NO
79SPARE RELAY - FURNISHING OF A SEPAM 20 type T20 RELAY AND DELIVER TO THE AVIANO A.B. PERSONNEL.
Rele' di riserva - Fornitura di un relè S.E. modello SEPAM 20 tipo T20 e consegna al personale della Base Aerea di Aviano.IT. No. Art. n.3.80EA/NO
LOGICAL BLOCKS AND SELECTIVITY INSTRUMENTAL TESTS
LOOP LOGICAL BLOCKS AND SELECTIVITY INSTRUMENTAL TESTS, TO VERIFY THE OPERATIVITY OF THE SYSTEM LOGIC-SELECTIVITY AFTER THE REPLACEMENT OF THE RELAYS ON LOOP. INCLUDED FINAL REPORT WITH ALL THE RESULTS.

Test strumentale dei blocchi logici e della selettività dell'anello di meia tensione, per accertare l'operatività della selettivià logica del sistema dopo la sostituzione dei relè sull'anello. Inclusa report finale completo di ogni risultato.

80Area "A1-A2" logical blocks test and selectivity test on the MV loopIT. No. Art. n.4.01LS/AC
81Area "F" logical blocks test and selectivity test on the MV loopIT. No. Art. n.4.02LS/AC
REPLACEMENT OF BATTERIES AND BATTERIES-CHARGERS
REPLACEMENT OF THE EXISTING RECTIFIER WITH NEW ONE, SINGLE-BRANCH TYPE, INPUT 230Vac, OUTPUT 24Vdc 40 Amps, 90 minutes AUTONOMY, 12 YEARS EXPECTED-LIFE Pb (VRLA) BATTERIES. INCLUDED RECONNECTION OF THE EXISTING IN & OUT CIRCUITS.
Sostituzione raddrizzatore esistente con nuovo, singolo ramo, ingresso 230Vca, uscita 24Vcc 40 Amp, autonomia 90 minuti, batterie Pb ermetico (VRLA) con vita attesa 12 anni. Compreso ricablaggio circuiti.IT. No. Art. n.5
82Area "F" - SUBSTATION F26B (bldg 921)IT. No. Art. n.5.01EA/NO
83Area "F" - SUBSTATION F40 "ARMY" (bldg 14357)IT. No. Art. n.5.02EA/NO
84Area "1" - SUBSTATION 151IT. No. Art. n.5.03EA/NO
85Area "1" - SUBSTATION 165IT. No. Art. n.5.04EA/NO
86Area "1" - SUBSTATION 177IT. No. Art. n.5.05EA/NO
87Area "1" - SUBSTATION 1204IT. No. Art. n.5.06EA/NO
88Area "1" - SUBSTATION 15100 (17004)IT. No. Art. n.5.07EA/NO
89Area "2" - SUBSTATION 246IT. No. Art. n.5.08EA/NO
90Area "2" - SUBSTATION 263IT. No. Art. n.5.09EA/NO
91Area "C" - SUBSTATION 420IT. No. Art. n.5.10EA/NO
92Area "E" - SUBSTATION 604IT. No. Art. n.5.11EA/NO
93Area "G" - SUBSTATION 15703IT. No. Art. n.5.12EA/NO
BATTERIES AND BATTERIES-CHARGES "SPD" PANEL
EMERGENCY POWER SUPPLY EQUIPMENT SPD PANEL. FURNISHING AND INSTALLATION OF POWER SUPPLY EQUIPMENT PANEL FOR THE PROTECTION OF THE EQUIPMENT AGAINST SURGES.
Quadro scaricatori per il sistema di alimentazione di emergenza. Fornitura ed installazione di quadro per la protezione contro le sovratensioni del sistema di alimentazione di emergenza.IT. No. Art. n.6
94Area "F" - SUBSTATION F26B (bldg 921)IT. No. Art. n.6.01LS/AC
95Area "F" - SUBSTATION F40 "ARMY" (bldg 14357)IT. No. Art. n.6.02LS/AC
96Area "1" - SUBSTATION 151IT. No. Art. n.6.03LS/AC
97Area "1" - SUBSTATION 165IT. No. Art. n.6.04LS/AC
98Area "1" - SUBSTATION 177IT. No. Art. n.6.05LS/AC
99Area "1" - SUBSTATION 12104IT. No. Art. n.6.06LS/AC
100Area "1" - SUBSTATION 15100IT. No. Art. n.6.07LS/AC
101Area "2" - SUBSTATION 246IT. No. Art. n.6.08LS/AC
102Area "2" - SUBSTATION 263IT. No. Art. n.6.09LS/AC
103Area "C" - SUBSTATION 420IT. No. Art. n.6.10LS/AC
104Area "E" - SUBSTATION 604IT. No. Art. n.6.11LS/AC
105Area "G" - SUBSTATION 15703IT. No. Art. n.6.12LS/AC
LOW VOLTAGE PROTECTION RELAYS FUNCTIONING CHECKS
FUNCTIONING CHECKS FOR LOW VOLTAGE (LV) CIRCUIT BREAKER PROTECTION RELAYS.
Esecuzione delle verifiche funzionali degli relè di bassa tensione.IT. No. Art. n.7
106Area "F" - SUBSTATION F1IT. No. Art. n.7.01LS/AC
107Area "F" - SUBSTATION F2IT. No. Art. n.7.02LS/AC
108Area "F" - SUBSTATION F3IT. No. Art. n.7.03LS/AC
109Area "F" - SUBSTATION F4AIT. No. Art. n.7.04LS/AC
110Area "F" - SUBSTATION F5IT. No. Art. n.7.05LS/AC
111Area "F" - SUBSTATION F6IT. No. Art. n.7.06LS/AC
112Area "F" - SUBSTATION F7IT. No. Art. n.7.07LS/AC
113Area "F" - SUBSTATION F8IT. No. Art. n.7.08LS/AC
114Area "F" - SUBSTATION F9IT. No. Art. n.7.09LS/AC
115Area "F" - SUBSTATION F10IT. No. Art. n.7.10LS/AC
116Area "F" - SUBSTATION F11IT. No. Art. n.7.11LS/AC
117Area "F" - SUBSTATION F12IT. No. Art. n.7.12LS/AC
118Area "F" - SUBSTATION F12AIT. No. Art. n.7.13LS/AC
119Area "F" - SUBSTATION F13IT. No. Art. n.7.14LS/AC
120Area "F" - SUBSTATION F14IT. No. Art. n.7.15LS/AC
121Area "F" - SUBSTATION F15IT. No. Art. n.7.16LS/AC
122Area "F" - SUBSTATION F16IT. No. Art. n.7.17LS/AC
123Area "F" - SUBSTATION F17IT. No. Art. n.7.18LS/AC
124Area "F" - SUBSTATION F18IT. No. Art. n.7.19LS/AC
125Area "F" - SUBSTATION F19IT. No. Art. n.7.20LS/AC
126Area "F" - SUBSTATION F20IT. No. Art. n.7.21LS/AC
127Area "F" - SUBSTATION F21IT. No. Art. n.7.22LS/AC
128Area "F" - SUBSTATION F22IT. No. Art. n.7.23LS/AC
129Area "F" - SUBSTATION F23IT. No. Art. n.7.24LS/AC
130Area "F" - SUBSTATION F24IT. No. Art. n.7.25LS/AC
131Area "F" - SUBSTATION F24AIT. No. Art. n.7.26LS/AC
132Area "F" - SUBSTATION F25IT. No. Art. n.7.27LS/AC
133Area "F" - SUBSTATION F26IT. No. Art. n.7.28LS/AC
134Area "F" - SUBSTATION F26BIT. No. Art. n.7.29LS/AC
135Area "F" - SUBSTATION F27IT. No. Art. n.7.30LS/AC
136Area "F" - SUBSTATION F28IT. No. Art. n.7.31LS/AC
137Area "F" - SUBSTATION F29IT. No. Art. n.7.32LS/AC
138Area "F" - SUBSTATION F30IT. No. Art. n.7.33LS/AC
139Area "F" - SUBSTATION F31IT. No. Art. n.7.34LS/AC
140Area "F" - SUBSTATION F32IT. No. Art. n.7.35LS/AC
141Area "F" - SUBSTATION F33IT. No. Art. n.7.36LS/AC
142Area "F" - SUBSTATION F34IT. No. Art. n.7.37LS/AC
143Area "F" - SUBSTATION F35IT. No. Art. n.7.38LS/AC
144Area "F" - SUBSTATION F36IT. No. Art. n.7.39LS/AC
145Area "F" - SUBSTATION F37IT. No. Art. n.7.40LS/AC
146Area "F" - SUBSTATION F38IT. No. Art. n.7.41LS/AC
147Area "F" - SUBSTATION F39IT. No. Art. n.7.42LS/AC
148Area "F" - SUBSTATION F40IT. No. Art. n.7.43LS/AC
149Area "F" - SUBSTATION F42IT. No. Art. n.7.44LS/AC
150Area "A1" - SUBSTATION 151IT. No. Art. n.7.45LS/AC
151Area "A1" - SUBSTATION 165IT. No. Art. n.7.46LS/AC
152Area "A1" - SUBSTATION 177IT. No. Art. n.7.47LS/AC
153Area "A1" - SUBSTATION 1204IT. No. Art. n.7.48LS/AC
154Area "A1" - SUBSTATION 15100 (17004)IT. No. Art. n.7.49LS/AC
155Area "A2" - SUBSTATION 246IT. No. Art. n.7.50LS/AC
156Area "A2" - SUBSTATION 263IT. No. Art. n.7.51LS/AC
157Area "C" - SUBSTATION 420IT. No. Art. n.7.52LS/AC
158Area "E" - SUBSTATION 604IT. No. Art. n.7.53LS/AC
159Area "G" - SUBSTATION 15703IT. No. Art. n.7.54LS/AC
MV RELAYS VERIFICATION AND TEST
VERIFICATION AND TEST OF THE MV RELAYS NOT INCLUDED IN THE SUBSTATIONS LIST OF THE ARTICLE #3.
Esecuzione delle verifiche dei relè 20 kV non inclusi nell'elenco delle cabine dell'articolo n°3.IT. No. Art. n.8
160Area "F", substation F1IT. No. Art. n.8.01LS/AC
161Area "F", substation F3IT. No. Art. n.8.02LS/AC
162Area "F", substation F5IT. No. Art. n.8.03LS/AC
163Area "F", substation F26BIT. No. Art. n.8.04LS/AC
164Area "F", substation F30IT. No. Art. n.8.05LS/AC
165Area "F", substation F36IT. No. Art. n.8.06LS/AC
166Area "F", substation F37IT. No. Art. n.8.07LS/AC
167Area "F", substation F40IT. No. Art. n.8.08LS/AC
168Area "A1", substation 165IT. No. Art. n.8.09LS/AC
169Area "A1", substation 1204IT. No. Art. n.8.10LS/AC
170Area "A1", substation 15100 (17004)IT. No. Art. n.8.11LS/AC
171Area "A2", substation 263IT. No. Art. n.8.12LS/AC
LV RELAYS REPLACEMENT
REPLACEMENT OF LV VOLTAGE PROTECTION RELAYS AND BREAKERS THAT ARE NOT LONGER OPERATIVE.
Sostituzione dei relè di bassa tensione e degli interruttori che non sono più funzionanti.IT. No. Art. n.9
172Area "F", substation F4AIT. No. Art. n.9.01Ea/NO
173Area "F", substation F5IT. No. Art. n.9.02Ea/NO
174Area "F", substation F20IT. No. Art. n.9.03Ea/NO
175Area "F", substation F22IT. No. Art. n.9.04Ea/NO
176Area "F", substation F23IT. No. Art. n.9.05Ea/NO
177Area "F", substation F24IT. No. Art. n.9.06Ea/NO
178Area "F", substation F28IT. No. Art. n.9.07Ea/NO
179Area "F", substation F39IT. No. Art. n.9.08Ea/NO
180Area "F", substation F42IT. No. Art. n.9.09Ea/NO
181Area "F", substation F42IT. No. Art. n.9.10Ea/NO
182Area "F", substation F42IT. No. Art. n.9.11Ea/NO
183Area "A1", substation 165IT. No. Art. n.9.12Ea/NO
184Area "A1", substation 165IT. No. Art. n.9.13Ea/NO
185Area "A1", substation 177IT. No. Art. n.9.14Ea/NO
186Area "A1", substation 1204IT. No. Art. n.9.15Ea/NO
187Area "A1", substation 1204IT. No. Art. n.9.16Ea/NO
188Area "A1", substation 15100 (17004)IT. No. Art. n.9.17Ea/NO
189Area "A2", substation 246IT. No. Art. n.9.18Ea/NO
190Area "A2", substation 246IT. No. Art. n.9.19Ea/NO
191Area "A2", substation 246IT. No. Art. n.9.20Ea/NO
192Area "A2", substation 246IT. No. Art. n.9.21Ea/NO
193Area "A2", substation 246IT. No. Art. n.9.22Ea/NO
194Area "C, substation 420IT. No. Art. n.9.23Ea/NO
195Area "E", substation 604IT. No. Art. n.9.24Ea/NO
196Area "G", substation 15703IT. No. Art. n.9.25Ea/NO
197Area "G", substation 15703IT. No. Art. n.9.26Ea/NO
MV MEASURE VOLTAGE TRANSFORMER REPLACEMENT
REPLACEMENT OF MV MEASURE VOLTAGE TRANSFORMER.
Sostituzione di trasformatore di tensione di misura, lato MTIT. No. Art. n.10
198Area "F", substation F4AIT. No. Art. n.10.01Ea/NO
199Area "F", substation F24AIT. No. Art. n.10.02Ea/NO
MV FUSES REPLACEMENT
REPLACEMENT OF MV FUSES.
Sostituzione di fusibili lato MTIT. No. Art. n.11
200Area "F", substation F8IT. No. Art. n.11.01Ea/NO
201Area "F", substation F37IT. No. Art. n.11.02Ea/NO
TEMPERATURE CONTROL UNIT FOR MV/LV TRANSFORMERS
REPLACEMENT OF THE EXISTING OUT-OF-SERVICE TEMPERATURE CONTROL UNITS FOR MV/LV CAST-RESIN TRANSFORMERS.
Sostituzione di centraline di controllo temperatura non funzionanti, idonee per trasformatori in resina.IT. No. Art. n.12
202Area "F", substation F3IT. No. Art. n.12.01Ea/NO
203Area "F", substation F19IT. No. Art. n.12.02Ea/NO
204Area "F", substation F25IT. No. Art. n.12.03Ea/NO
205Area "F", substation F39IT. No. Art. n.12.04Ea/NO
DOCUMENTATION AND DRAWINGS
206DRAWINGS AND DOCUMENTATIONS OF THE NEW AND EXISTING SYSTEM, DIVIDED PER SINGLE SUBSTATION.
Disegni e documenti degli impianti nuovi ed esistenti, divisi per ciascuna cabina.IT. No. Art. n.13LS/AC
LAPTOP AND PROGRAMMING SOFTWARE
207FURNISHING OF A LAPTOP WITH WITH INSTALLED SOFTWARE FOR THE PROGRAMMING OF THE RELAYS. INCLUDED TRAINING ON THE USE OF THE SOFTWARE.
Fornitura di un computer portatile con installati i software di programmazione dei relè. Inclusa formazione sull'uso dei software.IT. No. Art. n.14LS/AC
ORDINARY MAINTENANCE OF FUNCTIONING BATTERY CHARGERS
208ORDINARY MAINTENANCE OF #43 FUNCTIONING EMERGENCY POWER SUPPLY EQUIPMENT, INCLUDED LIQUID REFILLING OF THE Ni-Cd BATTERIES.
Manutenzione ordinaria di n°43 sistemi alimentazione di emergenza funzionanti, compreso il rabbocco del liquido delle batterie Ni-Cd.IT. No. Art. n.15LS/AC
"e-distribuzione" FEES
209RELEVANT FEES PAYMENT TO “e-distribuzione” TO SWITCH THE POINT OF DELIVERY, AND COORDINATION TO SCHEDULE AND ORGANIZE THE ACTIVITY.
Oneri e rapporti con "e-distribuzione" per commutare il punto di consegna.IT. No. Art. n.16LS/AC
DECLARATION OF COMPLIANCE "DI.DA."
ISSUED OF THE DECLARATION OF COMPLIANCE "DI.DA." FOR THE SUBSTATIONS SUBJECTED TO THE REPLACEMENT OF THE GENERAL PROTECTION SYSTEM (SPG).
Emissione della Dichiarazione di Adeguatezza "DI.DA." per le cabine soggette alla sostituzione del Sistema Protezione Generale (SPG).IT. No. Art. n.17
210Area "F", substation F12AIT. No. Art. n.17.01LS/AC
211Area "A2", substation #246IT. No. Art. n.17.02LS/AC
212Area "C", substation #420IT. No. Art. n.17.03LS/AC
213Area "E", substation #604IT. No. Art. n.17.04LS/AC
214Area "G", substation #15703IT. No. Art. n.17.05LS/AC

Total electrical - Totale Elettrico

TOTAL PART IV / Totale Parte IV

REPAIR WORKS SUMMARY / Riepilogo Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS
PART IV - ELECTRICAL WORK
TOTAL PRICE / Costo Totale0.000.000.000.00

OR US DOLLARS (RATE 1$ = 0,8978€)

Total Summary / Riepilogo Complessivo
A.REPAIR WORKS / Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS
PART IV - ELECTRICAL WORK
SUB TOTAL A / Subtotale A

TOTAL PRICE / Costo Totale

OR US DOLLARS (RATE FY21 1$ = 0,8978€)

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY Sheet &P of &N

GRAND TOTAL

ASHE 20-1063 - REPAIR MV SUBSTATIONS, MULTI - PHASE 2 REV020.8978
INSTRUCTIONS FOR COMPLETING AF FORM 3052

TOTAL MATERIAL COSTS € 0.00 $ 0.00

TOTAL LABOR COSTS € 0.00 $ 0.00

TOTAL OTHER DIRECT COSTS € 0.00 $ 0.00

TOTAL DIRECT COSTS € 0.00 $ 0.00

OVERHEAD % € 0.00 $ 0.00

€ 0.00 $ 0.00

PROFIT % € 0.00 $ 0.00

TOTAL PRICE € 0.00 $ 0.00

DATE FIRM NAME

TITLE BY

INSTRUCTIONS TO OFFERORS

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY

Col 1 Item. Description of materials required, work to be done, special equipment needed, etc. Breakdown should be in sufficient detail to permit itemizing of all direct costs.

Col 2 Unit of Measure. Description of the unit in which each item is to be estimated (examples - square yards-SY, cubic yards-CY, square feet- SF, linear feet-LF, board feet-BF, each-EA,, pound-LB).

Col 3 Quantity. Contractor's estimated of quantity required in terms of unit of measure (column 2). Item and units of measure will be furnished by the Government. Quantity estimates will be furnished by the Government only when it is anticipated that a unit price contract will be issued. Otherwise, the contractor is responsible for determining quantity estimates.

Col 4 and 5 Material Costs. Enter unit cost (Col 4) of material to be supplied and total cost (Col 5) for item listed in column 1.

Col 6, 7 and 8 Labor Costs. Enter in col 6 the estimated number of manhours or mandays needed to perform the work listed in column 1. Enter in col 7 the average rate per manhour (manday) and in col 8 the total labor cost.

Col 9 Other Direct Costs. Enter estimated costs of special equipment and other items (listed in column 1), which are special to the contract and of significant dollar value.

Col 10 Line. Self-explanatory.

Note: In addition to other totals entered on various pages, the grand total of column 10, plus overhead and profit will be shown on the last page as follows:

1. The purpose of this form is to provide a standard format by which the offeror submits to the Government a summary of incurred and estimated costs, (and attached supporting information) suitable for detailed review and analysis. Prior to the award of a contract resulting from this proposal, the offeror shall, under the conditions stated in ASPR 3-807.3, be required to submit a certificate of current cost or pricing data (see ASPR 3-807.3 and 3-807.4).

2. In addition to the specific information required by this form, the offeror is experted, in good faith, to incorporate in and submit with this form any additional data, supporting schedules, or substation which are reasonably required for the conduct of an appropriate review and analysis in the light of the specific facts of this procurement. For effective negotiations, it is essential that there be a clean understanding of:

a. The existing, verifiable data.

b. The judgmental factors applied in projecting from know data to the estimate, and

c. The contingencies used by the offeror in his proposed price.

In short, the offeror's estimating process itself needs to be disclosed.

3. When attachment of supporting cost or pricing data to this form is impracticable, the data will be described (with schedules as appropriate) and made available to the contracting officer or his authorized representative upon request.

4. By submission of this proposal the offeror grants to the contracting officer, or his authorized representative, the right to examine, for the purpose of verifying the cost or pricing data submitted, those books, records, documents and other supporting data which will permit adequate evaluation of such cost or pricing data, along with the computations and projections used therein. This right may be exercised in connection with any negotiations prior to contract award.

File details come from the government source that posted it. Updated .