Asbestos Materials Bldg 5 and 122.pdf

PDF 307 KB Posted

Attached to
491/20209. MAA; Caro Center - Various Building Demolitions
Solicitation number
RFQ - 171 - 230000000136
Issued by
Tuscola County, Capac Village, Michigan

About this file

This document is a report on the hazardous materials present in Buildings 5 and 122 related to a state and local contract opportunity in Michigan. The contract opportunity is for the demolition of various buildings at the Caro Center in Tuscola County and the Village of Capac. The report identifies the types and quantities of asbestos-containing materials (ACMs) and other hazardous materials found in the two buildings, including magnesium silicate piping, fire doors, debris, insulation, floor tiles, and other building materials. The quantities of these hazardous materials are provided for each building. This information is likely intended to be used in the scope of work or project description for the demolition contract.

The report does not include details on the pricing terms, set asides, incumbents, funding requirements, or other salient commercial information related to the contract opportunity. It focuses solely on the technical details of the hazardous materials present in the buildings to be demolished.

View the file

Other files

File Type Posted
Specification 20209 - Division 0 and 1.pdf PDF
Drawing Set 4.pdf PDF
Addendum 2 20209.pdf PDF
Division 1 - Section 013000.pdf PDF
Additional Materials to be Added.pdf PDF
Addendum 1 20209.pdf PDF
Sidewalk and Roadway Demo Limits.pdf PDF
Drawing Set 1.pdf PDF
Caro Center Basement Water Test Results.pdf PDF
Drawing Set 2.pdf PDF
Advertisement 20209.pdf PDF
Drawing Set 3.pdf PDF
Sign in Sheet.pdf PDF
Specification 20209 - Division 2 and 31.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos Materials

Building No. 5 - Psych

Hazardous Materials Number

Hazardous Materials Name Quantity ACM

HA-1 Magnesium Silicate Piping 952 LF Yes HA-2 MCI on Mag Piping 158 EA Yes HA-4 Fire Doors 60 EA Yes HA-6 ACM Debris on Ground 1,572 SF Yes HA-7 MCI of Fiberglass Piping 81 EA Yes HA-9 MCI on Woolfelt Piping 11 EA Yes HA-10 Burnham Boiler (1986) 1 EA Assumed HA-11 Hot Water Storage Tank 132 SF Yes HA-12 Thermal Brick in Chimney 840 SF Assumed HA-14 Aircell Pipe Insulation 142 SF Yes HA-15 Electrical Panels 6 EA Assumed HA-20 Sink Undercoating, Black 4 EA Yes HA-25 9” x 9” Floor Tile, Tan 443 SF Yes HA-28 12” x 12” Floor Tile, Red 16 SF Yes HA-29 12” x 12” Floor Tile, Dark Red 304 SF Yes

HA-30

Wood Paneling Glue 24 SF Yes

HA-31 9” x 9” Floor Tile, Dark Brown 42 SF Yes HA-35 Toilet Gaskets 9 EA Assumed HA-38 12" x 12" Floor Tile, White 257 SF Yes HA-39 9" x 9" Floor Tile, Gray 92 SF Yes HA-40 9" x 9" Floor Tile, Dark Brown 144 SF Yes HA-50 Pipe Gaskets and Flanges 50 EA Assumed

Building No. 122 - Grounds

Hazardous Materials Number

Hazardous Materials Name Quantity ACM

HA-1 Fire Door 5 EA Assumed HA-7 Toilet Gasket 1 EA Assumed HA-8 Heat Shield 1 SF Yes HA-9 Water Heater 1 EA Assumed HA-11 12” x 12” Floor Tile, White 180 SF Yes HA-13 Roof Sealant 4 SF Assumed