ARFQ DEP25-71 PIPE GATE DETAILS (1).pdf

PDF 282 KB Posted

Attached to
OSR Southern Maintenance - Open End
Solicitation number
ARFQ 0313 DEP2500000071 2
Issued by
Calhoun County, West Virginia

About this file

This is a technical specification document for ARFQ DEP25-71, detailing the design and construction requirements for a welded pipe gate system. The specification outlines a comprehensive gate assembly constructed primarily from Schedule 40 steel pipe, featuring an 18-foot overall length with a 2-inch inside diameter main pipe gate and a 6-inch inside diameter installation chamber. The gate design includes specific components such as a lock box assembly, hinge pins constructed from 1.5-inch inside diameter line pipe, grease fittings at each hinge point, and hardened steel reinforcement plates measuring 1/4-inch thickness. The lock box mechanism is engineered to accommodate up to four locks through designated 1/2-inch by 1.5-inch slots, with all pipe ends to be welded closed and the lock box circumference fully welded to the pipe gate. Installation requirements specify that the 6-inch diameter pipe area must be excavated to allow gate placement, then backfilled and compacted after installation.

The specification provides detailed dimensional requirements for all components, including precise measurements for slot dimensions, weld points, and spacing intervals. All steel materials must meet Schedule 40 specifications, and all welded construction must be executed to create a secure, functional gate system suitable for industrial or municipal applications. The document indicates the gate assembly is fabricated using welded construction methodology throughout, with particular attention to hinge durability through dedicated lubrication points. No pricing, funding sources, incumbents, or contract term information is provided in this technical specification document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCK BOX DETAIL

(SEE DETAIL)2" I.D. PIPE, WELDED

PIPE GATE, 18-FOOT DETAIL

(Typical both sides)

2" I.D. LINE PIPE

LOCK BOX

GREASE FITTINGS SHALL BE INSTALLED AT EACH HINGE POINT.

ALL ENDS OF PIPE SHALL BE WELDED CLOSED.

ALL STEEL PIPE SHALL BE SCHEDULE 40.

NOTES:

1 1/2" I.D. LINE PIPE

ON INSIDE, WELDED

ON ENDS

TO BE USED AS

HINGE PINS

(TYPICAL BOTH SIDES)

6" I.D. PIPE, WELDED

AREA TO BE EXCAVATED TO ALLOW

FOR INSTALLATION OF GATE, BACKFILLED

AND COMPACTED.

(Typical both sides)

1 3/4" x 1" SLOT

GATE PIPE

1/4"

THICK

HARDENED

STEEL

3"

1" 1/2"

(FRONT)

WELD

ENTIRE

CIRCUMFERENCE

OF LOCK

BOX TO

PIPE

GATE PIPE

WELD

POINT

3"

12"

5 1/8"

1"

1 1/2"

1/2"

1/4"

THICK

HARDENED

STEEL

(WELDED CONSTRUCTION)

1/4" STEEL PLATE

(SIDE)

LOCK

3" PIPE

12"

1/2" x 1 1/2"

SLOT TAB

NOTE: CAPABLE OF UTILIZING UP TO 4 LOCKS

3"

PIPE

3 1/2"

2 1/2"

1/2" 1/2"

1/

2"

1/

2"

PIPE G

ATE 18'

R

EQ

. O R

P.O . N o.

D

EPXXXXX

AutoCAD SHX Text %%P3'-1"

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

AutoCAD SHX Text 4'-11"

AutoCAD SHX Text 4'-9"

AutoCAD SHX Text 9'

AutoCAD SHX Text 1'

AutoCAD SHX Text 8"

AutoCAD SHX Text 18'

AutoCAD SHX Text 3'

Sheets and Views
8.5x11