Summary
This is an Asbestos Abatement Scope of Work document prepared by Environmental Technical Solutions (ETS) for the Auraria Higher Education Center (AHEC) regarding Phase II window abatement at the West Classroom Building located at 1050 10th Street Mall, Denver, Colorado 80204. The project involves the removal of approximately 384 square feet of trace asbestos-containing drywall systems with friable asbestos-containing joint compound to facilitate window replacement across four window types located throughout the building's first and second floors. The General Abatement Contractor (GAC) will deploy four separate crews working simultaneously in four different building areas to meet the general contractor's schedule. The project is scheduled to commence on May 16, 2026, and must be completed by June 12, 2026, with work hours available Monday through Sunday from 6:00 a.m. to 6:00 p.m. Prior inspections conducted by Clear Consulting in July 2024 identified drywall systems containing friable joint compounds with an estimated 2-3% chrysotile asbestos content, while subsequent sampling by ETS in January and February 2025 determined that window caulking and glazing bulk samples contained no detectable asbestos.
The scope requires unit pricing for removal of window caulking, window glazing, and trace asbestos-containing drywall systems, as well as secondary containment construction rates and labor costs broken down by worker, supervisor, and project manager hourly rates. All work must comply with Colorado Department of Public Health and Environment Regulation #8, OSHA 29 CFR 1926.1101, and EPA 40 CFR 61 Subpart M standards. The GAC is responsible for all regulatory notifications, including NESHAP notification to CDPHE, though a formal abatement permit is not anticipated. Environmental containment requirements include negative pressure ventilation maintained at minimum -0.02 inches of water column with a minimum four air exchanges per hour, one-chamber decontamination units within secondary containments, and three-chamber remote decontamination units. All asbestos waste must be double-bagged in 6 mil polyethylene bags with appropriate OSHA warning labels and disposed of at EPA-approved landfills. Final air clearance monitoring using Phase Contrast Microscopy must be conducted by a CDPHE-certified Air Monitoring Specialist, and all critical barriers must remain in place for a minimum of six hours following final visual inspection to allow for general contractor verification before dismantling.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2432 S. Downing Street, Denver, Colorado 80210 ● 303.722.2973 ● Fax: 303.722.2974
ASBESTOS ABATEMENT SCOPE OF WORK
AURARIA CAMPUS WEST CLASSROOM BUILDING
1050 10TH STREET MALL
DENVER, COLORADO 80204
(2026 PROJECT B PHASE II WINDOW ABATEMENT)
PREPARED FOR:
AURARIA HIGHER EDUCATION CENTER
1156 7TH AVENUE
MARCH 16, 2026
PROJECT NUMBER E25.104
Table of Contents
1.0 BACKGROUND
2.0 SCOPE OF WORK
3.0 SPECIAL CONDITIONS
3.1 Regulatory Notification and Variances
3.2 Building Occupancy Status
3.3 Site Security
3.4 Field Changes
4.0 PROJECT DESIGN
4.1 Standards & Primacy of Rules
4.2 Site Access
4.3 Equipment Staging Areas
4.4 Utilities Service
4.5 Decontamination Facilities
4.6 Load Out Facilities
4.7 Critical Barriers
4.8 Negative Pressure Ventilation
4.9 Containment Construction
4.10 Pre-Cleaning Activities
4.11 Asbestos Removal
4.12 Waste Removal
4.13 Final Clean Criteria
4.14 Final Air Clearance Monitoring
4.15 Routine Air Monitoring
4.16 Electrical Hazards Control
4.17 Emergency Egress and Fire Protection
4.18 Respiratory Protection
4.19 Documentation Submittal
Appendix A – Window Removal Table with Drywall Removal Locations and Quantities
Appendix B – Typical Window Layout Photo Log
Appendix C – Abatement Phase Drawings
Appendix D – Clear Consulting West Classroom Pre-Renovation Building Inspection for
Suspect Asbestos-Containing Materials, Window Unit Replacement Project Report, Dated
December 11, 2024
Appendix E – ETS’ West Classroom Building Limited Asbestos-Containing Material
Inspection Report, dated February 11, 2025
AHEC 2026 Project B Phase II Window Abatement March 16, 2026
ETS Project No. E25.104 Page 1
1.0 Background
Between July 2, 2024, and July 10, 2024, Clear Consulting performed limited asbestos building inspection services at the Auraria Campus West Classroom Building located at
1050 10th Street Mall, Denver, Colorado 80204. Clear Consulting identified drywall systems with friable asbestos containing joint compound that will need to be abated to facilitate the 2026 window replacement project or Project C.
Clear Consulting identified drywall systems with friable asbestos containing joint compound throughout the building. Composite drywall system bulk samples had analytical composite results of less than 1% asbestos content. The friable joint compounds contained an estimated 2-3% Chrysotile asbestos.
See Clear Consulting West Classroom Pre-Renovation Building Inspection for Suspect
Asbestos-Containing Materials, Window Unit Replacement Project Report, dated
December 11, 2024, in Appendix D for details.
On January 31, 2025, and February 6, 2025, Environmental Technical Solutions (ETS) performed limited bulk sampling of suspect asbestos containing window caulking and glazing identified throughout the building. Both the window caulking and glazing bulk samples collected were none detected for asbestos. See ETS’ West Classroom Building
Limited Asbestos-Containing Material Inspection Report, dated February 11, 2025, within Appendix E for details.
ETS will provide the building owner with project oversight and asbestos Air Monitoring
Specialist (AMS) services throughout abatement activities including final visual inspection and background air sampling within each containment work area.
2.0 Asbestos Scope of Work
1. Remove approximately 384 square feet of trace asbestos containing drywall systems with friable asbestos containing joint compound to facilitate window demolition.
Drywall will be removed in a straight line using manual removal methods or a mechanical means with a dustless shroud and a HEPA vacuum attached to the shroud inlet. Following removal, a light encapsulate will be applied using a spray bottle to the drywall edges. See the window removal table with window types, drywall removal locations, and quantities in Appendix A for details.
Type 1 Window Locations: The General Abatement Contractor (GAC) shall remove the MDF particle board at the window head and the associated vertical metal partition plate. No drywall is to be removed.
Type 2 Window Locations: The GAC shall remove approximately 6 inches of drywall at the vertical window jambs back to the interior partition wall.
Type 3 Stairwell Window Locations: The GAC shall remove approximately 4 inches of drywall at the vertical jambs.
ETS Project No. E25.104 Page 2
Type 4 Window Locations: The GAC shall remove approximately 12” of drywall at the locations where the wall returns at a 45-degree angle toward the windowsill.
See the Typical Window Layout Photo Log in Appendix B for details.
The window subcontractor will have 4 separate crews working in 4 different areas of the building at one time. Therefore, multiple abatement crews will be needed to meet the General Contractor’s schedule. See the abatement phase drawings within
Appendix C for details.
Unit Pricing
1. Supply unit rate to remove one linear foot of non-friable asbestos containing window caulking.
2. Supply unit rate to remove one linear foot of non-friable asbestos containing window glazing.
3. Supply unit rate to remove one square foot of non-friable trace asbestos containing drywall system.
4. Supply unit rate to construct one 5’ x 5’ secondary containment.
5. Provide Worker hourly rate.
6. Provide Supervisor hourly rate.
7. Provide Project Manager hourly rate.
3.0 Special Conditions
3.1 Regulatory Notification and Variances
The GAC will make all mandatory notifications to Federal and State entities regulating their work as required by applicable rules, regulations, and standards. This includes, but is not limited, to the National Emission Standards for Hazardous Air Pollutants
(NESHAP) notification (notice provided to the Colorado Department of Public Health and Environment (CDPHE) with permit application).
The GAC is responsible for quantifying amounts of ACM to be reported on the
CDPHE Notification Form and submitting any variances necessary to properly complete the project. If applicable, the GAC to supply an asbestos abatement project design including a drawing with the decontamination unit, load out and negative air machine locations of each work area. It is anticipated that this project will not require a CDPHE asbestos abatement permit or notification.
ETS Project No. E25.104 Page 3
3.2 Facility Occupancy Status
This building will remain occupied during the scheduled work activities. All areas designated for abatement shall be unoccupied for the duration of abatement operations.
The GAC shall maintain all work areas and equipment storage areas in a clean, orderly, and dust-free condition at all times.
3.3 Site Security
Access to the work area shall be strictly regulated. Entry to the regulated area is by permission only to authorized personnel. The perimeter of the work area shall be monitored at all times during abatement by a competent person. Only asbestos certified/licensed personnel employed by the GAC or federal and state regulatory agency personnel will be allowed access to the work area.
3.4 Field Changes
Minor modifications to the project design or scope of work by CDPHE or the Project
Designer are allowed. Minor changes include but are not limited to, relocation of decontamination facility and waste load-out.
4.0 Project Design
4.1 Standards and Primacy of Rules
The following standards will be adopted as they pertain to asbestos abatement. In any instance where adopted standards are in conflict with each other, the most stringent shall apply.
1) Colorado Department of Public Health and Environment Regulation #8
2) 29 CFR 1926.1101, the OSHA Construction Industry Asbestos Standard
3) 40 CFR 61 Subpart M, EPA’s NESHAP Asbestos Standard
4) NIOSH/OSHA/USCG/EPA –“Occupational; Safety & Health Guidance
Manual for Hazardous Waste Site Activities”, Section 8-20; Heat Stress and
Other Physiological Factors.
5) All other applicable laws, rules, and regulations, including but not limited to those relating to:
6) Workers’ Compensation Insurance;
7) Liability Insurance
8) All contract specifications and documentation
4.2 Site Access
The project is anticipated to start May 16th, 2026, and must be completed by June 12th, 2026. The GAC has access to the building for the purpose of abatement Monday through
Sunday from 6:00am to 6:00pm.
ETS Project No. E25.104 Page 4
4.3 Equipment Staging Areas
The GAC shall schedule pick-up and delivery of equipment, supplies and waste dumpsters. Waste containers should not impede the flow of pedestrian and vehicular traffic.
4.4 Utilities Service
Electrical power and water will be supplied by the building owner. The GAC to provide temporary electrical panels if needed. The GAC will also provide a licensed electrician to connect building power to temporary panels.
4.5 Decontamination Facilities
At a minimum a direct one-chamber decontamination unit is to be constructed for trace asbestos containing drywall system abatement operations inside a secondary containment.
Additionally, a remote three-chamber decontamination unit will be set up adjacent to the work areas for the duration of the project. The decontamination facility will be constructed and prepared in accordance with CDPHE Regulation 8, Part B- Asbestos.
The decontamination facility is to be maintained in a clean and orderly condition throughout the duration of the project.
4.6 Load Out Facilities
All load-out and disposal procedures shall be in accordance with CDPHE Regulation 8, Part
B- Asbestos. At a minimum each secondary containment work area will require a one-chamber waste load-out.
4.7 Critical Barriers
All penetrations of the structure will be sealed with critical barriers. All critical barriers will be constructed in accordance with CDPHE Regulation 8 Part B- Asbestos. Personnel constructing the containment or installing/removing critical barriers will be in proper personal protective equipment (PPE) such as but not limited to respirators and Tyvek suits or similar.
4.8 Negative Pressure Ventilation
Each work area will be placed under negative pressure. The negative pressure device
(NPD) is to be vented to the exterior of the building. The exterior negative pressure exhaust opening will be secured using a hard barrier if necessary. Negative pressure shall be maintained at a minimum of -0.02 inches of water column as verified by a portable monometer device and visible confirmation of negative air flow using a smoke tube device. The negative air system shall exchange the volume of air inside the containment area a minimum of four (4) times per hour.
ETS Project No. E25.104 Page 5
4.9 Containment Construction
Each secondary containment utilized for the removal of trace asbestos containing drywall systems will include at a minimum a one-chamber decontamination unit/waste load-out at each entrance to the containment. Each secondary containment for the asbestos removal shall be constructed in accordance with CDPHE Regulation 8, Part B-Asbestos and
OSHA 29 CFR 1926.1101 Asbestos Construction Standard. Each containment will require a pre-abatement visual inspection prior to the start of any removal activities. The
GAC will make every attempt to minimize the number of containments utilized for this project and will combine multiple rooms into a single secondary containment when feasible.
4.10 Pre-Cleaning Activities
The GAC shall perform pre-cleaning activities according to CDPHE, Regulation 8, Part
B- Asbestos. Personnel pre-cleaning will be in proper personal protective equipment
(PPE) such as but not limited to respirators and Tyvek suits or similar.
4.11 Asbestos Removal
Following approval of work area preparations by the Environmental Consultant/Project
Designer, the GAC may begin abatement activities. ACM removal will be performed in accordance with CDPHE Regulation 8, Part B – Asbestos.
Trace asbestos containing drywall systems with friable asbestos containing joint compound at a minimum will be removed within a secondary containment which will include a one-chamber decontamination unit/waste load out. OSHA 29 CFR 1926.1101
Asbestos Construction Standard will be followed during drywall removal activities.
The window subcontractor will have 4 separate crews working in 4 different areas of the building at one time. Therefore, multiple abatement crews will be needed to meet the
General Contractor’s schedule.
If previously unidentified non-friable asbestos containing window glazing or caulking are added to the scope of work during construction at a minimum will be removed according to CDPHE, Regulation 8, Part B- Asbestos, III.S.4 Abatement of Non-friable Asbestos
Containing Materials within a regulated work area.
The GAC will ensure that the work area is properly wetted or misted during abatement of
ACMs. The use of an airless sprayer will be used continuously to mist the work area. At the end of each shift the GAC shall ensure that all waste has been properly containerized prior to leaving the site.
ETS Project No. E25.104 Page 6
4.12 Asbestos Waste Removal
All ACM waste must be double-bagged in 6 mil polyethylene bags labeled with the appropriate OSHA warning label for asbestos and must also bear the generator label as required by EPA’s 40 CFR 61 Subpart M NESHAP Standard.
Containerizing and transport of asbestos wastes shall be in accordance with applicable regulations. It is the GAC responsibility to arrange for delivery and pickup of waste containers without impeding the flow of pedestrian and vehicular traffic. All waste load out activities shall be performed prior to 8:00AM, Monday through Friday. Waste load out activities performed on Saturday and Sunday may occur at any time, unless otherwise directed by the Owner or General Contractor.
The GAC will arrange for proper disposal of all waste materials at a landfill approved by the EPA to accept friable and non-friable asbestos waste. GAC employees are required to utilize protective coveralls and respirators when handling ACM waste that is double-bagged.
4.13 Final Clean/ Final Visual Inspection Criteria
All interior surfaces of the work areas will be free of visible dust and debris. Following completion of final cleaning, an encapsulant shall also be applied to any exposed edges of drywall where cuts were performed prior to final visual inspection. Each work area must pass a final visual inspection by a CDPHE certified AMS leaving only critical barriers in place.
4.14 Final Air Clearance Monitoring
Sample collection and analysis for background air monitoring within each containment work area following abatement shall be in accordance with CDPHE Regulation 8, Part B-
Asbestos and shall use Phase Contrast Microscopy (PCM).
Upon written notification that air monitoring levels are acceptable, the AMS shall authorize the GAC to remove critical barriers. Each secondary containment shall remain in place for a minimum of 6 hours following the final visual inspection and background air sampling to allow the General Contractor sufficient time to inspect and confirm that all work has been completed accurately and in accordance with the project specifications prior to dismantling the containment.
4.15 Personal Exposure Air Monitoring
The GAC shall be responsible for conducting personal exposure air monitoring as applicable in accordance with OSHA 29 CFR 1926.1101 Asbestos Construction
Standard.
ETS Project No. E25.104 Page 7
4.16 Electrical Hazards Control
All electrical power utilized during the project will be on ground fault circuit interrupters
(GFCI) whose power source is located outside the work area.
4.17 Emergency Egress and Fire Protection
A. Egress Points
1. The GAC shall develop an emergency egress plan and inform personnel of such plan.
B. Fire Protection Plan
1. No items capable of initiating or sustaining combustion (lighters, matches, torches, etc.) will be allowed in containment.
2. The use of flammable liquids is not permitted.
3. Any electricity utilized must be on Ground Fault Circuit Interrupters (GFCI).
4. A minimum of one, 2A:10B:C rated fire extinguishers will be maintained on-site. There must be available at least one 2A:10B:C rated fire extinguisher within a maximum travel distance of 50 feet from any point in the work area.
5. Workers will be trained in the use of fire extinguishers, emergency egress plans, basic fire safety, and emergency reporting procedures prior to work beginning.
6. All emergency exits will be labeled as such with tools available for breaching poly and keys in door locks where necessary.
7. The Contractor must implement an emergency action and fire prevention plan in accordance with 29 CFR 1910.38 Employee emergency plans and fire prevention plans.
C. Fall Protection Plan
1. The GAC shall comply with all applicable OSHA regulations, including but not limited to 29 CFR 1926 Subpart M – Fall Protection.
2. Fall protection shall be provided by the GAC for all employees exposed to falls of 6 feet or greater to a lower level during stairwell abatement activities.
3. Temporary guardrail systems meeting OSHA strength and height requirements (top rail 42 inches ± 3 inches and capable of withstanding 200 pounds of force).
It is anticipated that the GAC will need scaffolding and proper fall protection for the stairwell window removal.
ETS Project No. E25.104 Page 8
4.18 Respiratory Protection
The GAC personnel shall provide proper respiratory protection with NIOSH approved HEPA filters during all pre-clean, removal and waste load out procedures.
The GAC shall provide proof of medical fitness to wear respiratory protection and current fit testing documentation for all employees.
4.19 Document Submittal
Following de-mobilization, the GAC shall provide the following submittals to the
Owner:
✓ Copies of all regulatory inspections, orders, citations, or other correspondence related to this project.
✓ Daily logs
✓ GAC certifications and worker certifications
✓ Copies of all asbestos waste shipment manifests.
Following de-mobilization, Environmental Technical Solutions, LLC shall provide the following submittals to the Owner:
✓ Copies of all required visual inspections, air and/or bulk sampling results.
Prepared by:
Mike Pozzi
Project Designer s
Appendix A – Window Removal Table with Drywall Removal Locations and Quantities
Room Window Type Window Dimensions Drywall Quantity Removed SF
Additional Notes Window Types
162V Type 2 14' 11"x7' (x2) 5
1. Remove MDF particle board from header (no drywall), remove metal vertical partition plate from sides
P100JJ Type 2 4' 8"x7' (x2) 5
2. Remove drywall interior partition wall to window frame
162U Type 2 9' 11"x 7' 5
3. Remove 4” of drywall from the side of the window
162T Type 2 9' 11"x 7' 5
4. At angled corners remove 12” of drywall to window
162S Type 2 13' 6"x7' 5 162R Type 2 11' 5"x7' 5 162Q Type 2 9' 2"x 7' 5 162P Type 2 7'x 11"x 7' 5 162N Type 2 11' 7"x 7' 5 162M Type 2 14' 2"x7' 5 162L Type 2 9' 8"x 7' 5 156 Type 2 29' 10"x7' 5 152 Type 2 29' 9"x 7' 5 151 Type 2 29' 9"x 7' 5 150 Type 2 29' 9"x7 5 133F Type 2 16' 4" x 7' 5 133E Type 2 9' 10"x7' 5 133D Type 2 14' 10"x7' 5 133C Type 2 14' 9"x7 5 136S Type 2 14' 11" x 3' 11" 5 136R Type 2 9' 8"x 3' 11" 5 136Q Type 2 14' 9"x 3' 11" 5 139P Type 2 9' 9" x 3' 11" 5
Removed SF
Additional Notes Window Types
136N Type 2 9' 9" x 3' 11" 5
1. Remove MDF particle board from header (no drywall), remove metal vertical partition plate from sides.
136L Type 2 24' 9"x 3' 11" 5
2. Remove drywall interior partition wall to window frame
136K Type 2 9' 8"x 3' 11" 5
3. Remove 4” of drywall from the side of the window
136J Type 2 9' 8"x 3' 11" 5
4. At angled corners remove 12” of drywall to window
136H Type 2 9' 8"x 3' 11" 5 136G Type 2 9' 8"x 3' 11" 5 136F Type 2 9' 8"x 3' 11" 5 143 Type 2 24' 9"x 3' 11" 5 145 Type 2 39' 10"x 3'11" 5 147 Type 2 25'x3'11" 5 268 Type 2 20'x3' 11" 5 266D Type 2 14' 10"x 3'11" 5 266D1 Type 2 4'8" x 3' 11" 5 266C Type 2 14' 7" x 3' 11" 5 262 Type 2 29' 11"x 3' 11" 5 254K Type 2 9' 5" x 3' 11" 5 254J Type 2 9' 5" x 3' 11" 5 254H Type 2 9' 5" x 3' 11" 5 254G Type 2 9' 5" x 3' 11" 5 254F Type 2 9' 5" x 3' 11" 5 254E Type 2 9' 5" x 3' 11" 5 254D Type 2 9' 5" x 3' 11" 5 254C Type 2 14' 11"x 3' 11" 5
Removed SF
Additional Notes Window Types
254B Type 2 9' 5" x 3' 11" 5
1. Remove MDF particle board from header (no drywall), remove metal vertical partition plate from sides.
254A Type 2 9' 5" x 3' 11" 5
2. Remove drywall interior partition wall to window frame
236K Type 2 14' 11" x 3' 11" 5
3. Remove 4” of drywall from the side of the window
236J Type 2 and Type 4 9' 1" x 3' 11" 6
Southeast corner 45 angle, northeast corner normal drywall removal needed
4. At angled corners remove 12” of drywall to window
236 Type 2 and Type 4 9' 1" x 3' 11" 6
Northwest corner 45 angle, northeast corner normal drywall removal needed
236H Type 2 9' 10"x3'11" 5 236G Type 2 9' 10"x3'11" 5 236F Type 2 9' 10"x3'11" 5 236E Type 2 13'10" x3'11" 5 232 Type 2 19' 11"x 3' 11" 5 229 Type 2 and Type 4 8' 2" x 3' 11" 6 NE window has the 45 degree 230 Type 2 7' 3" x 3' 11" 5 233 Type 2 30'2" 3 ' 11" 5 234 Type 2 14'11"x 3' 11" 5 235 Type 2 14'11"x 3' 11" 5 237 Type 2 and Type 4 19' 11"x 3' 11" 5 238 Type 2 and Type 4 27' 11"x 3' 11" 6
S200A Type 2 and Type 3 13'x 3' 11" type 2, 14' 11"x 7' Type 3 7
240D Type 1 and Type 2 60' 7" x 3'11" 3 Southwest wall has drywall
Removed SF
Additional Notes Window Types
240E Type 1 16' 8" x 3' 11" 0
1. Remove MDF particle board from header (no drywall), remove metal vertical partition plate from sides.
240G2 Type 1 10'x 3'11" 0
2. Remove drywall interior partition wall to window frame
240G2A Type 1 10'x 3'11" 0
3. Remove 4” of drywall from the side of the window
240G Type 1 15' x3' 11" 0
4. At angled corners remove 12” of drywall to window
242L Type 1 15' x3' 11" 0 242M Type 1 15' x3' 11" 0 242P Type 1 15' x3' 11" 0 242S Type 1 30' x 3' 11" 0 242T Type 1 10' x 3' 11" 0 242W Type 1 10' x 3' 11" 0 242Y Type 1 10' x 3' 11" 0 242Z Type 1 14' 9" x 3' 11" 0 244A Type 2 25' x 3' 11" 5 247K Type 2 10' x 3' 11" 5 247J Type 2 10' x 3' 11" 5 247H Type 2 10' x 3' 11" 5 247G Type 2 10' x 3' 11" 5 247F Type 2 10' x 3' 11" 5 247E Type 2 10' x 3' 11" 5 247E Type 2 10' x 3' 11" 5 247D Type 2 10' x 3' 11" 5
Removed SF
Additional Notes Window Types
247C Type 2 10' x 3' 11" 5
1. Remove MDF particle board from header (no drywall), remove metal vertical partition plate from sides.
247B Type 2 14' 3' 11" 5
2. Remove drywall interior partition wall to window frame
Total Removal (SF) 384
3. Remove 4” of drywall from the side of the window
4. At angled corners remove 12” of drywall to window
Appendix B – Typical Window Layout Photo Log
TYPICAL WINDOW PHOTO LOG
Auraria Campus West Classroom Building, 1050 10th Street Mall, Denver, CO 80204
Type 1 - Remove MDF particle board (noted above) from header (no drywall), remove metal vertical partition plate from sides
Type 1 - Remove MDF particle board from header (no drywall), remove metal vertical partition plate from sides (noted above)
Type 2 – Remove drywall interior partition wall to window frame
Type 3 - Remove 4” of drywall from the side of the window
Type 4 – At angled corners remove 12” of drywall to window
Appendix C – Abatement Phase Drawings
132A
132B
132C 132D 132E
132F
132G
133C 133D
133E
133F
P100AA
P100JP100M
154155
P100N
P100P
C100C
C100A
V100B
V100A
S100A
L100A
C100B
145A P100CC
109 SF
979 SF
202 SF
434 SF
91 SF
110 SF
37 SF
562 SF
357 SF
258 SF
483 SF
484 SF
1065 SF
582 SF
P100EE
45 SF
113 SF 114 SF
162 SF
164 SF
165 SF
108 SF
51 SF
236 SF288 SF
30 SF
47 SF
2553 SF
2785 SF93 SF
643 SF
185 SF
684 SF
484 SF
484 SF
320 SF
1055 SF
160B
160A
483 SF
160C
160D
12 SF
95 SF
133H
598 SF
159 SF
C133
133B
94 SF
133G
82 SF
282 SF
C132
132H
133A
85 SF
132J
79 SF
487 SF
162X
162V
162W
P100JJ
162U 162T 162S 162R 162Q 162P
162A 162B
162C 162D 162E 162F 162G 162H
162N 162M 162L
162K
162J
156 152 151
P100HH
136E
136F
136G 136H 136J
136C
136B
136K
136L
136A
136W
136V
136U
136T
136S
136R136Q
136P136N
136D
823 SF
926 SF
48 SF
170 SF
103 SF 109 SF
108 SF
221 SF
165 SF
1128 SF
101 SF
93 SF
126 SF
191 SF
141 SF
93 SF
142 SF
116 SF116 SF
115 SF
114 SF
114 SF
110 SF
109 SF
873 SF
864 SF
875 SF
158 SF
26 SF
137 SF 137 SF
191 SF 162 SF
167 SF
148 SF
137 SF 94 SF
95 SF
88 SF 83 SF
88 SF 88 SF
118 SF
16 SF
117 SF
183 SF
165 SF113 SF131 SF
141 SF
130 SF
160 SF140 SF
153A 153B
153C
295 SF
C162
C136
642 SF
852 SF
119 SF
124 SF
121 SF131 SF
62 SF
177 SF
103 SF
R100D
284 SF
R100C
328 SF
P100K
42 SF
P100L
79 SF
Abatement Phasing
2026 AHEC West Classroom Window Project
West Classroom 1050 10th Street, Denver, Colorado 80204
Figure 1-1
2432 S. Downing Street Denver, CO 80210 303.722.2973 ets-us.net
Date: 02/26/2026 1st floor
6/3/26 - 6/5/26 5/27/26 - 6/2/26 5/19/26 - 5/26/26 5/16/26 - 5/18/26
5/16/26 - 5/18/265/19/26 - 5/26/265/27/26 - 6/2/26
GAC Crew 1
GAC Crew 2
247A
247B
247C 247D
247E
247F
247G
247K
247H
247J
P200N
S200AA
C200AA
CLASSROOM
TO
CENTRAL
P200K
P200W
244A
247M
127 SF
724 SF
8 SF
10 SF
418 SF
562 SF
583 SF
132 SF
110 SF
14 SF
312 SF
311 SF
416 SF
1429 SF
420 SF
462 SF
20 SF
1000 SF
1113 SF
379 SF
595 SF
379 SF
630 SF
133 SF117 SF
209 SF
791 SF
BUILDING
TO
ARTS
BUILDING
TO
ARTS
C200BB
1546 SF
247L
247N 247P
139 SF
139 SF
138 SF
157 SF
123 SF
126 SF
110 SF
109 SF
123 SF
247Q
22 SF
632 SF
266D
266D1
266C
266B
266A
262A
254L
254K 254J 254G 254F 254E
254M 254N
254P 254Q 254R 254S 254T
254U
254V
254A254B 254C
254D
236N236M
236L
236K
236J
236H
236G
236F
236B2
236A1
236E
236D
236C
113 SF
117 SF 117 SF
105 SF 110 SF
119 SF 124 SF
125 SF 125 SF
127 SF
101 SF
185 SF
158 SF
158 SF
146 SF
533 SF
342 SF
141 SF
152 SF
118 SF118 SF
178 SF
117 SF
118 SF117 SF117 SF
894 SF
13 SF
142 SF
150 SF
158 SF
104 SF
336 SF
31 SF
C236B
256 SF
C
A
S
F
70 SF
152 SF
152 SF
70 SF
151 SF
165 SF
100 SF
142 SF
C254
C247
560 SF
556 SF
236A
236A2
70 SF
236B1
70 SF
82 SF
240E
282 SF
240F
160 SF
240B
55 SF
240A
138 SF
240A1
55 SF
240D
1837 SF
240C
1842 SF
S200BB
99 SF
C
S
F
C200DD
1980 SF
254H
117 SF
254W
26 SF
223 SF
P200L
P J
59 SF
4880 SF
339 SF
S
F
121 SF
205 SF
R200CR200D
379 SF
295 SF
242DD
242FF
242Z
252 SF
242Y
166 SF
242W
165 SF
242T
509 SF
242S
509 SF
242P
251 SF
242M
251 SF
242L
165 SF
240G
303 SF
240G2A
70 SF
240G2
163 SF
242K
76 SF
242N
94 SF
242J
84 SF
242A
91 SF
242H
76 SF
242G
104 SF
242Q
241 SF
242R
242 SF
242U
242 SF
242V
240 SF
242BB
73 SF
242X
94 SF
242F1
94 SF
242CC
73 SF
240H
533 SF
242E
153 SF
242D
143 SF
242B
104 SF
242A
104 SF
V242F1
74 SF
124 SF
242HH
240 SF
242GG
242 SF
242F
855 SF
242EE
256 SF
242AA
108 SF
V242F2
71 SF
C242A
697 SF
C D
S
F
242C
323 SF
C B
S
F
C242C
1221 SF
P200G
34 SF
P200M
240G1
41 SF
Figure 1-2
Date: 02/26/2026 2nd floor
2432 S. Downing Street Denver, CO 80210 303.722.2973 ets-us.net
5/26/26 - 5/29/26 5/16/26 - 5/18/26
6/1/26 - 6/5/266/8/26 - 6/12/26
Fall Protection Plan Required
Abatement Phasing
2026 AHEC West Classroom Window Project
West Classroom 1050 10th Street, Denver, Colorado 80204
5/16/26 - 5/18/265/19/26 - 5/26/265/27/26 - 6/3/26
5/19/26 - 5/22/26
GAC Crew 3
GAC Crew 4
Appendix D – Clear Consulting West Classroom Pre-Renovation Building Inspection for
Suspect Asbestos-Containing Materials, Window Unit Replacement Project Report, Dated
PRE-RENOVATION BUILDING INSPECTION
FOR
SUSPECT ASBESTOS-CONTAINING MATERIALS
WINDOW UNIT REPLACEMENTS PROJECT
WEST CLASSROOM
AURARIA CAMPUS
1050 10TH STREET MALL
Prepared for:
Auraria Higher Education Center Facilities Services
1156 7th Street Denver, Colorado 80217
Prepared by:
Clear Consulting, LLC 37159 Pheasant Run
Elizabeth, Colorado 80107
TABLE OF CONTENTS
SECTION PAGE
1.0 Project Scope of Work 1
2.0 Project Personnel 3
3.0 Regulatory Review – Asbestos-Containing Materials 3
4.0 Identified Asbestos-Containing Materials 4
5.0 Identified Non-Asbestos-Containing Materials 4
6.0 Identified Materials Containing “Trace” Amounts of Asbestos 9
7.0 Drywall Materials with ACM Joint Compound – Composite Analysis 9
8.0 Conclusions and Recommendations 13
9.0 Building Inspector Attestation and Signature 13
EXHIBIT A:
Suspect Asbestos-Containing Materials – Bulk Sample Log
EXHIBIT B:
Building Floor Plans
• Floor Plan No. 1: Floor 1
Approximate Bulk Sample Locations
• Floor Plan No. 2: Floor 2 Approximate Bulk Sample Locations
• Floor Plan No. 3: Floor 1 Areas/Locations of Identified ACM
• Floor Plan No. 4: Floor 2 Areas/Locations of Identified ACM
EXHIBIT C:
Analytical Laboratory Reports - Polarized Light Microscopy
EXHIBIT D: Consulting Firm and Personnel Certifications
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
1.0 PROJECT SCOPE OF WORK
Pre-renovation inspections of the West Classroom Building (WC-1139) located on the Auraria Higher Education Center (AHEC) campus were conducted from Tuesday, July 2, 2024 through Wednesday, July 10, 2024 by Clear Consulting, LLC for suspect asbestos-containing materials (ACM) that will potentially be impacted by the scheduled replacement of window units located on Floors 1 and 2 and storefront/exterior door units located on Floor 1. The purpose of the inspections was to locate and sample suspect materials associated with the specific areas of the building to be impacted in order to compile an inventory of identified ACMs.
The inspection was conducted for Auraria Higher Education Center (AHEC) and the building is located on the AHEC Campus at 1050 10th Street Mall in Denver, Colorado.
1.1 INSPECTION FOR SUSPECT ASBESTOS-CONTAINING MATERIALS (ACM)
During the inspection conducted by Clear Consulting, LLC, the following suspect ACMs were identified by homogeneous areas of presence for the collection of bulk samples:
• Drywall walls – non-textured with joint compound (31 homogeneous areas)
• Interior window stool adhesive (1 homogeneous area)
For the identification of ACM, a sampling scheme was utilized that employed the selection of sample locations for suspect materials on a random basis and the quantity of samples collected were in compliance with the requirements of the U.S. Environmental Protection Agency (USEPA) Asbestos Hazard Emergency Response Act (AHERA), 40 CFR 763, Subpart E, as required by Colorado Air Quality Control Commission (AQCC), Regulation No. 8 for the inspection of school and commercial buildings.
Each bulk sample collected has an identification number that begins with the following acronym sequence:
• WC-1139-
This acronym sequence is followed by the room/area number identifying the location of the sample collection.
This room/area number is followed by another acronym describing each suspect material, followed by a sequential homogeneous area number (if applicable), and last by a sequential individual sample number.
• CDW = non-textured drywall with joint compound
• WSA = interior window stool adhesive
The thirty-one (31) homogeneous areas of non-textured drywall with joint compound (CDW) located throughout the exterior perimeter walls and associated with window/storefront/exterior door unit locations on Floors 1 and 2 of the building were separated and identified as follows:
• CDW 01-01 to 01-07 - Floor 2 – exterior perimeter drywall walls – pink/tan drywall w/ off-white compound
• CDW 01-08 to 01-14 – Floor 1 – exterior perimeter drywall walls - pink/tan drywall w/ off-white compound
• CDW 02: Floor 2 – 266D - south drywall partition wall – tan/grey drywall with white compound
• CDW 03: Floor 2 – 254K – south drywall partition wall – tan/off-white drywall with cream compound
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
• CDW 04: Floor 2 – 254H/254J – south drywall partition walls – tan/grey/ drywall with cream compound
• CDW 05: Floor 2 – 254C/254D – south drywall partition walls – tan/grey drywall with cream compound
• CDW 06: Floor 2 – 229/236 - drywall infill at columns – tan/off-white drywall with off-white compound
• CDW 07: Floor 2 – 238 - drywall infill at columns – tan/off-white drywall with off-white compound
• CDW 08: Floor 2 – 254B/254K – drywall infill at windows – grey/tan drywall with cream compound
• CDW 09: Floor 1 – 147 – south drywall partition wall – tan/off-white drywall with white compound
• CDW 10: Floor 1 – 136H/136J – drywall partition wall – tan/off-white drywall with off-white compound
• CDW 11: Floor 1 – 147 – drywall infill at column – tan/off-white drywall with off-white compound
• CDW 12: Floor 1 – P100JJ - drywall partition walls – tan/grey drywall with cream compound
• CDW 13: Floor 1 – 162N/162P - drywall partition wall – tan/off-white drywall with cream compound
• CDW 14: Floor 1 – 136G/136L - drywall partition walls – tan/off-white drywall with off-white compound
• CDW 15: Floor 1 – 132F/136R - drywall partition walls – white/tan drywall with cream compound
• CDW 16: Floor 1 – 150 - drywall infill at column – tan/off-white drywall with cream compound
• CDW 17: Floor 1 – 152/156 - drywall partition walls – grey/tan drywall with cream compound
• CDW 18: Floor 1 – 136G/K/R - drywall partition walls - pink/tan drywall with off-white compound
• CDW 19: Floor 1 – 132D/133F - drywall infill at windows – white/grey/tan drywall with white compound
• CDW 20: Floor 1 – 152/156 - drywall infill at columns – grey/tan drywall with white compound
• CDW 21: Floor 1 – 162L/P/T - drywall infill at columns – off-white/tan drywall with white compound
• CDW 22: Floor 2 – 236E/236H - drywall partition walls – off-white/tan drywall with off-white compound
• CDW 23: Floor 2 – 237 – east drywall partition wall - grey/tan drywall with white compound
• CDW 24: Floor 2 – 240C/240D – exterior perimeter/lower wall – grey/tan drywall with white compound
Note: building area completely renovated/reconfigured – original 244A/259 and south to Suite 239
• CDW 25: Floor 2 – 242L/242T - drywall partition walls – grey/tan drywall with white compound
• Note: building area completely renovated/reconfigured – original 244A/259 and south to Suite 239
• CDW 26: Floor 2 – 247G/247H - drywall partition walls – pink/tan drywall w/white/off-white compound
• CDW 27: Floor 2 – 266C/268 – drywall infill at windows - pink/tan drywall w/white/off-white compound
• CDW 28: Floor 2 – 254B/254K - drywall infill at windows – pink/tan/off-white drywall w/white compound
• CDW 29: Floor 2 – 236E/236G – drywall infill at windows – off-white/tan drywall with white compound
• CDW 30: Floor 2 – 229/233 - drywall partition walls - pink/tan drywall with white compound
• CDW 31: Floor 2 – 247J/247K - drywall partition wall - pink/tan drywall with white compound
The one (1) homogeneous area of interior window stool adhesive (WSA) located under metal window stool covers was identified as follows:
• WSA 01: Floor 1 – 145/151 – window stool cover adhesive – brown resinous material
Bulk samples of the suspect materials encountered were collected and each sample was assigned a unique identification number. Bulk samples were collected by an EPA/State of Colorado certified building inspector.
All samples were submitted to Eurofins Reservoirs Environmental, Inc. (ERE), a third-party independent laboratory. ERE is accredited through the National Voluntary Laboratory Accreditation Program (NVLAP) as required by USEPA. Bulk samples were analyzed by Polarized Light Microscopy (PLM) in general compliance with guidelines established by 40 CFR 763, Subpart E. Asbestos concentrations were visually estimated and/or point counted and reported by percent for each layer of the sample.
The specific information regarding the identified ACM is presented in Section 4.0 of this report.
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
2.0 PROJECT PERSONNEL
The following representatives of Clear Consulting, LLC, certified as Building Inspectors as required by Colorado Department of Public Health and Environment (CDPHE), Air Pollution Control Division (APCD), conducted the building inspections for suspect ACMs at the West Classroom Building:
Clear Consulting, LLC: ACF No. 14902
Name of Building Inspector: H. Kim Thiel
State of Colorado Certification No.: 668
Name of Building Inspector: Frank Hulce
State of Colorado Certification No.: 1849
Name of Building Inspector: Jayson Windle
State of Colorado Certification No.: 4266
3.0 REGULATORY REVIEW – ASBESTOS-CONTAINING MATERIALS
USEPA and Colorado Department of Public Health and Environment (CDPHE) regulate all building materials that contain greater than 1% asbestos as determined by polarized light microscopy (PLM) analysis. The Occupational Health and Safety Administration (OSHA) regulates any building materials containing greater than 1% asbestos as well as smaller amounts of asbestos (“trace” amounts of 1% or less but greater than 0%) that may result in an airborne asbestos exposure due to physical disturbance.
USEPA and CDPHE Regulation No. 8, Part B, requires that suspect ACM in buildings built prior to 1988 be assumed to be asbestos-containing or an inspection be conducted by an EPA-accredited/CDPHE-certified asbestos building inspector. CDPHE, Regulation No. 8, Part B, requires an asbestos inspection in compliance with the AHERA protocol be conducted prior to demolition or renovation activities that could disturb ACM.
The USEPA and CDPHE require all friable ACMs be removed prior to renovation or demolition and any non-friable ACMs that may be rendered friable by those same activities.
In some circumstances, “point count” analysis is required for bulk samples previously identified by PLM. Point counting is a more detailed method of analysis than standard PLM. Federal and state agencies define ACM as materials containing greater than 1% asbestos. The NESHAP regulation requires that if standard PLM analysis determines that a sample contains less than 10% asbestos, the material must be considered asbestos-containing or be point counted.
CDPHE Regulation No. 8 (Section III.A.1.c.) requires that if the asbestos content of a sample of friable asbestos is estimated to be 1% asbestos or less, but greater than 0%, by a method other than point counting, the determination shall be repeated using the point counting technique with PLM and if the result obtained is different from the PLM result, the point count result must be used.
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
4.0 IDENTIFIED ASBESTOS-CONTAINING MATERIALS
• No encountered suspect materials sampled were identified as ACM.
4.1 LOCATIONS AND QUANTIFICATION OF IDENTIFIED ASBESTOS-CONTAINING MATERIALS
The following summary itemizes the locations of the identified ACM.
• No encountered suspect materials sampled were identified as ACM.
5.0 IDENTIFIED NON-ASBESTOS-CONTAINING MATERIALS
The following suspect materials were sampled, analyzed, and identified as non-asbestos-containing materials:
• Drywall walls – non-textured with joint compound (19 homogeneous areas)
• Interior window stool adhesive (1 homogeneous area)
5.1 LOCATIONS AND QUANTIFICATION OF IDENTIFIED NON-ASBESTOS CONTAINING MATERIALS
The following samples of suspect material were collected during the current inspection and were identified as non-ACM:
Note: Due to the assumption that all drywall partition walls adjacent or perpendicular to exterior perimeter walls, drywall infills at columns, and drywall infills at window units are OSHA drywall (Refer to Section 8) based upon the visual homogeneity of these materials, the approximate quantities of the following identified non-ACM, non-textured drywall walls are irrelevant but reported as approximate below.
Identified Non-ACM Description Location Approximate Quantity
Non-Textured Drywall (CDW 02) – 1 H.A. Floor 2
266D Partition Wall
800 Sq. Ft.
Non-Textured Drywall (CDW 03) – 1 H.A. Floor 2
254K South Partition Wall
300 Sq. Ft.
Non-Textured Drywall (CDW 04) – 1 H.A. Floor 2
Suite 254 (Partial) Partition Walls
1,500 Sq. Ft.
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
Non-Textured Drywall (CDW 05) – 1 H.A. Floor 2
Suite 254 (Partial)
1,500 Sq. Ft.
Non-Textured Drywall (CDW 08) – 1 H.A. Floor 2
Suite 254 Window Recesses
200 Sq. Ft.
Non-Textured Drywall (CDW 09) – 1 H.A. Floor 1
South Partition Wall
850 Sq. Ft.
Non-Textured Drywall (CDW 12) – 1 H.A. Floor 1
P100JJ
450 Sq. Ft.
Non-Textured Drywall (CDW 17) – 1 H.A. Floor 1
150/151/152/156
3,200 Sq. Ft.
Non-Textured Drywall (CDW 20) – 1 H.A. Floor 1
150/151/152/156 Drywall Column Infills
60 Sq. Ft.
Non-Textured Drywall (CDW 21) – 1 H.A. Floor 1
Suite 162 Column/Window Infills
300 Sq. Ft.
Non-Textured Drywall (CDW 23) – 1 H.A. Floor 2
East Drywall Partition Wall
600 Sq. Ft.
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
Non-Textured Drywall (CDW 24) – 1 H.A. Floor 2
Southwest Remodeled Area Exterior Perimeter
Lower Walls
1,800 Sq. Ft.
Non-Textured Drywall (CDW 25) – 1 H.A. Floor 2
Southwest Remodeled Area Drywall Partition Walls
15,000 Sq. Ft.
Non-Textured Drywall (CDW 26) – 1 H.A. Floor 2
Suite 247 (Partial)
2,800 Sq. Ft.
Non-Textured Drywall (CDW 27) – 1 H.A. Floor 2
268/Suite 266 Drywall Window Recesses
60 Sq. Ft.
Non-Textured Drywall (CDW 28) – 1 H.A. Floor 2
Suite 254
Non-Textured Drywall (CDW 29) – 1 H.A. Floor 2
Suite 236
50 Sq. Ft.
Non-Textured Drywall (CDW 30) – 1 H.A. Floor 2
229 through 237
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
Non-Textured Drywall (CDW 31) – 1 H.A. Floor 2
Suite 247
100 Sq. Ft.
Window Stool Adhesive (WSA 01) – 1 H.A. Floors 1 and 2
Window Stool Metal Caps Unknown
5.2 CLASSIFICATION AND PHYSICAL ASSESSMENT OF NON-ACM
Identified Non-ACM Description Classification Physical Assessment
Non-Textured Drywall (CDW 02) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 03) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 04) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 05) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 08) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 09) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 12) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 17) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 20) – 1 H.A. Miscellaneous – Non-Friable Good Condition
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
Non-Textured Drywall (CDW 21) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 23) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 24) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 25) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 26) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 27) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 28) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 29) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 30) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 31) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Window Stool Adhesive (WSA 01) – 1 H.A. Miscellaneous – Non-Friable Good Condition
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
6.0 IDENTIFIED MATERIALS CONTAINING “TRACE” AMOUNTS OF ASBESTOS
Suspect materials can yield results indicating “trace” amounts of asbestos (1% or less but greater than 0%).
These materials are not regulated as ACM but require removal methods to comply with the exposure limits stipulated by the OSHA Construction Standard for Asbestos (29 CFR 1926.1101) with regard to their disturbance and/or removal:
• No encountered suspect materials sampled were identified with “trace” amounts of asbestos.
6.1 LOCATIONS AND QUANTIFICATION OF IDENTIFIED “TRACE” MATERIALS
6.2 CLASSIFICATION AND PHYSICAL ASSESSMENT OF “TRACE” MATERIALS
6.3 POINT COUNT ANALYSES OF “TRACE” MATERIALS
7.0 DRYWALL MATERIALS WITH ACM JOINT COMPOUND – COMPOSITE ANALYSIS
Drywall materials without applied texture containing asbestos in amounts greater than 1% in only the joint compound component of the drywall system may be subjected to “composite” analysis. This procedure as conducted by the Polarized Light Microscopy (PLM) analytical laboratory considers the percentage of the entire drywall system bulk sample that is asbestos-containing joint compound as compared to the rest of the bulk sample and, accordingly, yields a “composite” result indicating the percentage of asbestos within the entire drywall system bulk sample.
Composite analysis is only permissible for drywall systems that are non-textured and composite results yielding an asbestos content of 1% or less renders the abatement/demolition of the drywall system to a status of “OSHA” drywall. These materials may therefore be removed/demolished employing limited engineering controls and by utilizing removal methods that meet the requirements for protecting employees/personnel from airborne asbestos fibers through compliance with the exposure limits stipulated by the OSHA Construction Standard for Asbestos (29 CFR 1926.1101) regarding the disturbance and/or removal of asbestos-containing materials.
• Drywall walls – non-textured with joint compound (12) homogeneous areas)
Note: Due to the assumption that all drywall partition walls adjacent or perpendicular to exterior perimeter walls are OSHA drywall (Refer to Section 8) based upon the visual homogeneity of these materials, the approximate quantities of the following identified non-ACM, non-textured drywall walls are irrelevant but reported as approximate below.
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
7.1 LOCATIONS AND QUANTIFICATION OF OSHA DRYWALL MATERIALS
Identified OSHA Drywall Description Location Approximate Quantity
Non-Textured Drywall (CDW 01) – 1 H.A. Floors 1 and 2
Exterior Perimeter Walls 15,000 Sq. Ft.
Non-Textured Drywall (CDW 06) – 1 H.A. Floor 2
Southeast Section
100 Sq. Ft.
Non-Textured Drywall (CDW 07) – 1 H.A. Floor 2
50 Sq. Ft.
Non-Textured Drywall (CDW 10) – 1 H.A. Floor 1
Suite 136 (Partial)
1,200 Sq. Ft.
Non-Textured Drywall (CDW 11) – 1 H.A. Floor 1
30 Sq. Ft.
Non-Textured Drywall (CDW 13) – 1 H.A. Floor 1
162N/162P
240 Sq. Ft.
Non-Textured Drywall (CDW 14) – 1 H.A. Floor 1
Suite 136 (Partial)
Non-Textured Drywall (CDW 15) – 1 H.A. Suites 132/133 (Partial)
1,100 Sq. Ft.
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
Non-Textured Drywall (CDW 16) – 1 H.A. Floor 1
80 Sq. Ft.
Non-Textured Drywall (CDW 18) – 1 H.A. Floor 1
Suite 136 (Partial)
Non-Textured Drywall (CDW 19) – 1 H.A. Floor 1
Suites 132/133
1,100 Sq. Ft.
Non-Textured Drywall (CDW 22) – 1 H.A. Floor 2
Suite 236 (Partial)
1,400 Sq. Ft.
CLASSIFICATION AND PHYSICAL ASSESSMENT OF OSHA DRYWALL MATERIAL
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 01) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 06) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 07) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 10) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 11) – 1 H.A. Miscellaneous – Non-Friable Good Condition
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
Non-Textured Drywall (CDW 13) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 14) – 1 H.A. Miscellaneous – Non-Friable Good Condition Identified Non-ACM Description Classification Physical Assessment
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 15) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 16) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 18) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Identified OSHA Drywall Description Classification Physical Assessment
Non-Textured Drywall (CDW 19) – 1 H.A. Miscellaneous – Non-Friable Good Condition
Non-Textured Drywall (CDW 22) – 1 H.A. Miscellaneous – Non-Friable Good Condition
7.3 COMPOSITE ANALYSIS OF OSHA DRYWALL
• Non-Textured Drywall Walls (CDW 01) – Composite Analysis = 0.23%
• Non-Textured Drywall Walls (CDW 06) – Composite Analysis = 0.74%
• Non-Textured Drywall Walls (CDW 07) – Composite Analysis = 0.18%
• Non-Textured Drywall Walls (CDW 10) – Composite Analysis = 0.06%
• Non-Textured Drywall Walls (CDW 11) – Composite Analysis = 0.19%
• Non-Textured Drywall Walls (CDW 13) – Composite Analysis = 0.12%
• Non-Textured Drywall Walls (CDW 14) – Composite Analysis = 0.27%
• Non-Textured Drywall Walls (CDW 15) – Composite Analysis = 0.16%
• Non-Textured Drywall Walls (CDW 16) – Composite Analysis = 0.10%
• Non-Textured Drywall Walls (CDW 18) – Composite Analysis = 0.06%
• Non-Textured Drywall Walls (CDW 19) – Composite Analysis = 0.13%
• Non-Textured Drywall Walls (CDW 22) – Composite Analysis = 0.20%
AURARIA HIGHER EDUCATION CENTER WEST CLASSROOM
PRE-RENOVATION BUILDING INSPECTION DECEMBER 11, 2024
8.0 CONCLUSIONS AND RECOMMENDATIONS
• The identified ACM in the form of joint compound associated with twelve (12) drywall window recesses, concrete column recesses, and partition walls attached (adjacent or perpendicular) to or in contact with window/storefront/exterior door unit frames have been subjected to composite analyses thereby rendering them non-regulated by U.S. Environmental Protection Agency (EPA) and Colorado Department of Public Health and Environment (CDPHE). However, all materials identified with less than 1% but greater than 0% asbestos content are regulated by U.S. Occupational Safety and Health Administration (OSHA) due to the potential exposure to airborne asbestos fibers upon physical disturbance, such as demolition. As such, unprotected construction/demolition personnel should not conduct physical impact-causing activities on these less than 1% but greater than 0% asbestos content materials and it is therefore recommended that these drywall components should be demolished/removed by a CDPHE-licensed GAC to facilitate the removal of the window unit frames by the GC. Any resultant generated waste materials may be disposed as general construction waste.
Note: There are a total of thirty-one (31) homogenous…