Appendix F - HazMat Survey.pdf
PDF 4 MB Posted
- Solicitation number
- FA301625Q0221
About this file
This document is an Asbestos Bulk Analysis Report prepared by Environmental Hazards Services for the United States Air Force Base. The report details asbestos testing conducted on multiple samples from Building 230 at Randolph Air Force Base in Texas, with laboratory analysis performed on March 9-10, 2017. Multiple material samples were collected from various locations including pipe insulation, wall surfaces, floor tiles, and window glazing across different rooms such as the shop, storage areas, mechanical spaces, and restrooms.
The laboratory results consistently showed "No Asbestos Detected" (NAD) for most samples, with a few notable exceptions. Specifically, floor tile mastics were identified as containing 6% Chrysotile asbestos, and the sink undercoating was positive for 3% Chrysotile asbestos. The samples were analyzed using EPA Method 600/R-93/116 and 600/M4-82-020, with the laboratory recommending further analysis by Transmission Electron Microscopy (TEM) for materials containing less than 10% asbestos. The report is part of a complete renovation project for Building 230, and all materials were carefully documented with detailed descriptions of composition, color, and texture.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Bulk Analysis Report
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
United States Air Force Base 03/22/2017
45-6537
03/27/2017
17-03-02982
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
905_Install Monitor; 12866_Conf, 856_Wall_230_Drive Thru; JBSA Randolph TX
Laboratory Results Fax Number:
210-652-3685
902 CES/CEAN 1651 5th St., West Randolph AFB, TX 78150
03/25/2017
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
White Paint-Like;
Powdery; Granular; Brown Fibrous; Inhomogeneous
17-03-02982-001 905-WLSH-004-
B-001
25% Cellulose 2% Fibrous Glass 73% Non-Fibrous
NAD
White Granular;
Homogeneous
17-03-02982-002 905-WLJ-004-B-
100% Non-FibrousNAD
White Paint-Like;
Powdery; Brown Fibrous;
Inhomogeneous
17-03-02982-003 905-WLSH-005-
B-001
25% Cellulose 2% Fibrous Glass 73% Non-Fibrous
NAD
White Paint-Like;
Powdery; Brown Fibrous;
Inhomogeneous
17-03-02982-004 905-WLSH-005-
B-002
25% Cellulose 2% Fibrous Glass 73% Non-Fibrous
NAD
White Paint-Like;
Powdery; Inhomogeneous
17-03-02982-005 905-WLSH-005-
B-003
8% Cellulose 92% Non-Fibrous
NAD
1 of 3Page
03/27/2017
12873_-Remove Wall - Sheetrock and float mud/joint compound is NAD, No Asbestos Detected
All reports combined are for the complete renovation of B230
1150049179C Work Orders
White Paint-Like;
Granular; Inhomogeneous
17-03-02982-006 905-WLJ-005-B-
100% Non-FibrousNAD
White Paint-Like;
Granular; Inhomogeneous
17-03-02982-007 905-WLJ-005-B-
100% Non-FibrousNAD
White Paint-Like;
Granular; Inhomogeneous
17-03-02982-008 905-WLJ-005-B-
100% Non-FibrousNAD
Beige Powdery; Brown Fibrous; Inhomogeneous
17-03-02982-009 856-WLSH-001-
B-001
30% Cellulose 2% Fibrous Glass 68% Non-Fibrous
NAD
White Paint-Like;
Granular; Inhomogeneous
17-03-02982-010 856-WLJ-001-B-
100% Non-FibrousNAD
Beige Powdery; Brown Fibrous; Inhomogeneous
17-03-02982-011 856-WLSH-002-
B-001
30% Cellulose 2% Fibrous Glass 68% Non-Fibrous
NAD
White Paint-Like;
Granular; Inhomogeneous
17-03-02982-012 856-WLJ-002-B-
100% Non-FibrousNAD
Pink Brown;
Homogeneous
17-03-02982-013 230-WGLZ-001-
B-0041
100% Non-FibrousNAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-6537 17-03-02982
905_Install Monitor; 12866_Conf, 856_Wall_230_Drive Thru; JBSA Randolph TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
2 of 3Page
1150049179C Underline
Underline
Pink Brown;
Homogeneous
17-03-02982-014 230-WGLZ-001-
B-0042
100% Non-FibrousNAD
Pink Brown;
Homogeneous
17-03-02982-015 230-WGLZ-001-
B-0043
100% Non-FibrousNAD
Missy Kanode
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Sami Hosn
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
88-M22011-4
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0 VELAP 460172. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-6537 17-03-02982
905_Install Monitor; 12866_Conf, 856_Wall_230_Drive Thru; JBSA Randolph TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
3 of 3Page
Lab Order ID: 1218324
Project: 3_11130; 208_80167; 230_11142;
379_11148;
Date Received: 11/8/2012
Date Reported: 11/8/2012
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: Edward Vogel Analysis ID: 1218324PLM
Customer: 902 CES/CEAN 1651 5th Street West Randolph AFB, TX 78150
3-WGLZ-0011-
B-001
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_1
100% Other
None Detected
3-WGLZ-0011-
B-002
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_2
100% Other
None Detected
3-WGLZ-0011-
B-003
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_3
100% Other
None Detected
3-WGLZ-0011-
B-004
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_4
100% Other
None Detected
3-WGLZ-0011-
B-005
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_5
100% Other
None Detected
3-WGLZ-0011-
B-006
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_6
100% Other
None Detected
208-WLSH-
004-B-001
Room 35; sheetrock; west White Non Fibrous Heterogeneous
Crushed1218324PLM_7
2% Cellulose 98% Other
None Detected
208-WLSH-
004-B-002
Room 35; sheetrock; west White Non Fibrous Heterogeneous
Crushed1218324PLM_8
3% Cellulose 97% Other
None Detected
Nathaniel Durham, MS or Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Bart Huber (18)
1150049179C Typewritten Text Lighting Survey - All ceiling planks are None Detect ffor Asbestos Containing Materials
1150049179C Typewritten Text
1150049179C Typewritten Text
1150049179C Typewritten Text
Certification
379_11148;
Date Received: 11/8/2012
Date Reported: 11/8/2012
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: Edward Vogel Analysis ID: 1218324PLM
Customer: 902 CES/CEAN 1651 5th Street West Randolph AFB, TX 78150
230-CLPK-
001-B-001
Shop; ceiling plank White Non Fibrous Homogeneous
Crushed1218324PLM_9
100% Other
None Detected
230-CLPK-
001-B-002
Shop; ceiling plank White Non Fibrous Homogeneous
Crushed1218324PLM_10
100% Other
None Detected
230-CLPK-
001-B-003
Shop; ceiling plank White Non Fibrous Homogeneous
Crushed1218324PLM_11
100% Other
None Detected
379-WLSH-
001-B-001
Room 17; sheetrock; south White Non Fibrous Heterogeneous
Crushed1218324PLM_12
2% Cellulose 98% Other
None Detected
379-WLSH-
001-B-002
Room 17; sheetrock; south White Non Fibrous Heterogeneous
Crushed1218324PLM_13
2% Cellulose 98% Other
None Detected
379-WLSH-
001-B-003
Room 17; sheetrock; south White Non Fibrous Heterogeneous
Crushed1218324PLM_14
3% Cellulose 97% Other
None Detected
379-WLJ-001-
B-004 - A
Room 17; flot mud/joint compound; south joint compound
White Non Fibrous Homogeneous
Crushed1218324PLM_15
100% Other
None Detected
379-WLJ-001-
B-004 - B
Room 17; flot mud/joint compound; south mastic
Brown Non Fibrous Homogeneous
Dissolved1218324PLM_18
100% Other
None Detected
Nathaniel Durham, MS or Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
379_11148;
Date Received: 11/8/2012
Date Reported: 11/8/2012
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: Edward Vogel Analysis ID: 1218324PLM
Customer: 902 CES/CEAN 1651 5th Street West Randolph AFB, TX 78150
661-WLPL-
002-B-001 - A
Room 4; wall plaster/CMU brick; west single layer plaster
White Non Fibrous Heterogeneous
Crushed1218324PLM_16
100% Other
None Detected
661-WLPL-
002-B-001 - B
Room 4; wall plaster/CMU brick; west brick
Red Non Fibrous Homogeneous
Crushed1218324PLM_17
100% Other
None Detected
Nathaniel Durham, MS or Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Randolph AFB Asbestos Inventory
Facility Type
Facility Site: BASE
Unknown
Square Footage: 27254Number of Floors: 1
B230.tifDrawing File Name:
Facility Status Manned
230.jpgPhoto File Name
Date Constructed: 1931
Facility Number: Facility Name:230 ACFT COR CON
Facility Owner: 12 MSG/CE
Facility Address: 211159 ACFT COR CON Asbestos:
Facility Summary Report:
11/09/2012 - Workorder 11142, Light Survey requested. All Ceiling planks are NAD, (No Asbestos Detected).
All bulbs are sodium vapor in the shop area and fluorescent in the spray booth areas. Both types contain mercury contaminants and if removed must be disposed of at Bldg 37 as universal waste. If removed by contractor, they must be handled as Recylable materials or Hazardous Waste. If recycled, a copy of the bill of lading or a manifest will be completed and provided to Base Environmental indicating total lbs recycled. If handled as Hazardous Waste, a completed manifest except for Generator signature will be provided to Base Environmental. Only Base Environmental has authority to sign as generator of materials.
This authority will not be delegated to the contractor..
12 May 10, 2GWLAN ProjectArea of penetration is NAD for Asbestos
Asbestos Containing Material (ACM) Results: Dimension:
AsbestosHSA DescriptionHSA Type Sample # Year ID Location(s) Floor Floor Area:
Sample Area:
Original Sample IDSample ID
0NAD, Non-Fibrous 100%
2012 1
Off White; Brittle;ChalkyCeiling Plank 1 SF
Shop 01 SF230-CLPK-001-B-001
0NAD, Non-Fibrous 100%
2012 1
Off White; Brittle;ChalkyCeiling Plank 2 SF
Shop 01 SF230-CLPK-001-B-002
0NAD, Non-Fibrous 100%
2012 1
Off White; Brittle;ChalkyCeiling Plank 3 SF
Shop 01 SF230-CLPK-001-B-003
Lead Based Paint Detected:
AcFft Maintenance
Randolph AFB LBP Inventory
Square Footage: 9614
Number of Floors: 1
None.tif
Drawing File Name:
Facility Status Manned
230.jpg
Photo File Name
Date Constructed: 1931
Facility Number: Facility Name:230 Corrosion Control
Facility Owner: 902 CES
Facility Type
Facility Address: BASE
Facility Summary Report:
11/9/2012 - Workorder 11142 - Request for Lighting Survey - All light fixtures are Negative for LBP
12/13/2012 - Recommend Approval. -Workorder 80091 - Paint Spray Booths - Even though the spray booths are positive for Lead Based Paint materials,The Corrosion Control shop has the repiratory equipment to prevent potential Lead exposure to their workers. If there are any paint chips , paint dust etc, double bag material and dispose of at the Hazardous Waste building 37.
11/21/2011 - Evaluate area for Lead Based Paint CITS Project - area for installation of subpanel is Positive for LBP. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater. A negative determination will be required for this project by a certified Lead Firm
09/20/2011 Workorder 80077, Self Help. Construct Changing Room for workers. All areas are Positive for Lead Based Paint.
However, as long as all holes are drilled wet with respiratory equipment on, the Self Help is approved. This shop has the proper equipment to conduct this type of work and Mr. Seagraves has been briefed.
8/2/11, WO#10449 Upgrade NIPERNET areas tested are negative for LBP.
15 Feb 11, Workorder 10055, Install Conduit. The areas that are Positive are above the area of proposed installation. The negative areas are the exact location of conduit installation.
230Lead Based Paint Samples for Facility Sample Date Room Side Quadrant Component Substrate Color Condition Pb PbErr Result
11 11/7/2012 0 0Shop Bay Middle Light Fixtures Metal Green Intact Negativ
1150049179C Typewritten Text
1150049179C Typewritten Text
Typewritten Text
Lab Order ID: 1302181
Project: 230_80173, 235_80177, 598_P3989, 100_11176
Date Received: 2/12/2013
Date Reported: 2/12/2013
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: Edward Vogel Analysis ID: 1302181PLM
Customer: 902 CES/CEAN 1651 5th Street West Randolph AFB, TX 78150
230-WGLZ-
001-B-001
Shop; window glazing; North Gray Non Fibrous Heterogeneous
Crushed1302181PLM_1
100% Other
None Detected
230-WGLZ-
001-B-002
Shop; window glazing; North Pink, Gray Non Fibrous Heterogeneous
Crushed1302181PLM_2
100% Other
None Detected
230-WGLZ-
001-B-003
Shop; window glazing; North Gray Non Fibrous Heterogeneous
Crushed1302181PLM_3
100% Other
None Detected
100-FLVCT-
002-B-001 - A
Rm 312; floor tiles and mastic tile
Brown Non Fibrous Heterogeneous
Dissolved1302181PLM_4
8% Chrysotile 92% Other
100-FLVCT-
002-B-001 - B
Rm 312; floor tiles and mastic mastic
Black Non Fibrous Heterogeneous
Dissolved1302181PLM_15
5% Chrysotile 95% Other
100-FLVCT-
002-B-002 - A
Rm 312; floor tiles and mastic tile
1302181PLM_5
Not Analyzed
100-FLVCT-
002-B-002 - B
Rm 312; floor tiles and mastic mastic
1302181PLM_16
Not Analyzed
100-FLVCT-
002-B-003 - A
Rm 312; floor tiles and mastic tile
1302181PLM_6
Not Analyzed
Nathaniel Durham, MS or Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Ired Gulley (17)
1150049179C Typewritten Text
1150049179C Typewritten Text
1150049179C Typewritten Text
1150049179C Typewritten Text
1150049179C Typewritten Text
1150049179C Typewritten Text
1150049179C Typewritten Text Work order 80173_ Remove paint from windows - All window glazing is NAD, No Asbestos Detected
1150049179C Underline
100_11176
Date Received: 2/12/2013
Date Reported: 2/12/2013
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: Edward Vogel Analysis ID: 1302181PLM
Customer: 902 CES/CEAN 1651 5th Street West Randolph AFB, TX 78150
100-FLVCT-
002-B-003 - B
Rm 312; floor tiles and mastic mastic
1302181PLM_17
Not Analyzed
100-WLJ-003-
B-001
Rm. Military justice; float mud; joint compound; West
White Non Fibrous Heterogeneous
Teased1302181PLM_7
100% Other
None Detected
100-WLSH-
003-B-002
Rm. Military justice;
sheetrock; West
White Non Fibrous Heterogeneous
Teased1302181PLM_8
100% Other
None Detected
598-HMAS-
001-B-001
Rm. Community; HDUCT mastic
White, Brown Fibrous Heterogeneous
Dissolved1302181PLM_9
20% Cellulose 80% Other
None Detected
598-CLLI-001-
B-002
Rm. Community; ceiling tile;
medium fissure; pinholes
White Fibrous Heterogeneous
Teased1302181PLM_10
40% 40%
Cellulose Fiber Glass
10% 10%
Perlite Other
None Detected
40-PWRP-001-
B-001
Tool area; pipe wrap; North White Fibrous Heterogeneous
Teased1302181PLM_11
80% Cellulose 20% Other
None Detected
235-WLJ-001-
B-001
Rm 13; float mud/joint compound; North
White Non Fibrous Heterogeneous
Teased1302181PLM_12
100% Other
None Detected
235-WLSH-
001-B-002
Rm 13; sheetrock; North White Fibrous Heterogeneous
Teased1302181PLM_13
5% Cellulose 95% Other
None Detected
Nathaniel Durham, MS or Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Ired Gulley (17)
100_11176
Date Received: 2/12/2013
Date Reported: 2/12/2013
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: Edward Vogel Analysis ID: 1302181PLM
Customer: 902 CES/CEAN 1651 5th Street West Randolph AFB, TX 78150
235-WLSH-
002-B-001
Rm 19; sheetrock; North White Fibrous Heterogeneous
Teased1302181PLM_14
8% Cellulose 92% Other
None Detected
Nathaniel Durham, MS or Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Scientific Analytical Institute 4604 DUNDAS Dr. GREENSBORO, NC 27407
Phone: 336.292.3888 Fax: 336.292.3313 www.sailab.comlab@sailab.com
Lab Use Only ; . ) Lab Order ill : 3r2J.=1 g ~ Client Code: ____ ___
Company Contact Information
I
Company: 902 CES/CEAN Contact: Edward VogelJ
Address: 1651 5th Street West Phone [gJ: 210-652-4668
JBSA Randolph IX Fax [gJ: 210-652-3685
Email 0: edward.vogel@us.af.mil e_vogel@att.net
Billing/Invoice Information Turn Around Times Company: II 90 Min. 0 48 Hours 0 Contact: II 3 Hours 0 72 Hours 0 Address: 6 Hours 0 96 Hours 0 r 12 Hours 0 120 Hours 0 I 24 Hours [gJ 144+Hours 0
PO Number:
Project NameINumber: 230 80173,235 80177,598 P3989,100 11176
Lead Test Types
PLM EPA 600/R-93/116
Positive stop as indicated
[gJ [gJ
PLM Point Count D
PCM NIOSH 7400 0
TEMAHERA 0
TEM Levelll 0
TEM NIOSH 7402 0
TEM Bulk Qualitative 0 TEM Bulk Chatfield 10 TEM Bulk Quantitative 10 TEM Wipe ASTM JD6480-99 0 TEM Microvac ASTM D5755-02 0
I TEM Water EPA 100.2 0 I Other: AAS 0
SampJelD# Description/Location Volume/Area Comments
230-WGLZ-001-B
Shop; Window Glazing; North Positive Stop 1
230-WGLZ-001-B
Shop; Window Glazing; North
230·WGLZ-001-B
Shop; Window Glazing; North
1OO-F LVCT-002
B-001 rm 312; ; Floor Tiles and mastic /\/ Positive Stop 1
1'OO-FLVCT-002
B-002 rm 312; ; Floor Tiles and mastic ;~ "
1OO-FLVCT-002
B-003 rm 312; ; Floor Tiles and mastic ..tPZ ' "
100-WLJ-003-B
, 001
Rm. Military Justice; Float Mud; Joint Compound; ·fi West I
100-WLSH-003-B
Rm. Military Justice; Sheetrock; West
•I
Relinquished by Daterrime
Edward Vogel 211 1113 1500
Received by
Total # of Samples _ 14_
Daterrime
I {) ~ ~O
Page __ 1_ of_)__ Scientific Analytical Institute A-F-010 mailto:www.sailab.comlab@sailab.com
Lab Use Only Scientific Analytical Institute Lab Order ill: ______302-L Pomona Dr. Greensboro, Ne 27407 CHent Code: ______Phone: 336.292.3888 Fax: 336.292.3313 www.sailab.comlab@sailab.com
SampleID# DescriptionlLocation Volume! Area Comments
598-HMAS-001-B
Rm . Community; HDUCT Mastic
I I
598-CLLI-001-B-002 Rm . Community;Ceiling Tile ; Medium Fissure;
Pinholes
40-PWRP-0011-B
Tool Area; Pipe Wrap; North
235-WLJ-001-'B-001 Rm 13; Float Mud/Joint Compound; North
235-WLSH-001-B
Rm 13; Sheetrock; North
235-WLSH-002-B
Rm 19; Sheetrock; South
I
I
I
I .
I I
I
Facility Site: BASE
Maintenance
Square Footage: 27254Number of Floors: 1
B230.tifDrawing File Name:
Facility Status Manned
230.jpgPhoto File Name
Date Constructed: 1931
Facility Number: Facility Name:230 ACFT COR CON
Facility Owner: 12 MSG/CE
Facility Address: 211159 ACFT COR CON Asbestos:
Facility Summary Report:
03/04/2013 - Workorder 80173 - Remove all paint from Windows - All window Glazing is NAD, No Asbestos Detected
11/09/2012 - Workorder 11142, Light Survey requested. All Ceiling planks are NAD, (No Asbestos Detected).
All bulbs are sodium vapor in the shop area and fluorescent in the spray booth areas. Both types contain mercury contaminants and if removed must be disposed of at Bldg 37 as universal waste. If removed by contractor, they must be handled as Recylable materials or Hazardous Waste. If recycled, a copy of the bill of lading or a manifest will be completed and provided to Base Environmental indicating total lbs recycled. If handled as Hazardous Waste, a completed manifest except for Generator signature will be provided to Base Environmental. Only Base Environmental has authority to sign as generator of materials.
This authority will not be delegated to the contractor..
12 May 10, 2GWLAN ProjectArea of penetration is NAD for Asbestos
Asbestos Containing Material (ACM) Results: Dimension:
AsbestosHSA DescriptionHSA Type Sample # Year ID Location(s) Floor Floor Area:
Sample Area:
Original Sample IDSample ID
0No Sample Results
2013 1
Off WhiteCementitiousWindow Glazing None SF
Shop 01 SF230-WGLZ-001-B-003
0NAD, Non-Fibrous 100%
2013 1
Off White; Grray; CementitiousWindow Glazing 1 LF
Shop 01 SF230-WGLZ-001-B-001
0NAD, Non-Fibrous 100%
2013 1
Off White; Tan; Red;CementitiousWindow Glazing 2 LF
Shop 01 SF230-WGLZ-001-B-002
Randolph AFB LBP Inventory
Square Footage: 9614
Number of Floors: 1
None.tif
Drawing File Name:
Facility Status Manned
230.jpg
Photo File Name
Date Constructed: 1931
Facility Number: Facility Name:230 Corrosion Control
Facility Owner: 902 CES
Facility Type
Facility Address: BASE
Facility Summary Report:
03/04/2013 - Workorder 80173 - Remove all paintfrom Shop Windows - All window metal components are Positive for LBP. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. All work must be done by a Lead Certified Firm. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater.
/9/2012 - Workorder 11142 - Request for Lighting Survey - All light fixtures are Negative for LBP
12/13/2012 - Recommend Approval. -Workorder 80091 - Paint Spray Booths - Even though the spray booths are positive for Lead Based Paint materials,The Corrosion Control shop has the repiratory equipment to prevent potential Lead exposure to their workers. If there are any paint chips , paint dust etc, double bag material and dispose of at the Hazardous Waste building 37.
11/21/2011 - Evaluate area for Lead Based Paint CITS Project - area for installation of subpanel is Positive for LBP. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater. A negative determination will be required for this project by a certified Lead Firm
09/20/2011 Workorder 80077, Self Help. Construct Changing Room for workers. All areas are Positive for Lead Based Paint.
However, as long as all holes are drilled wet with respiratory equipment on, the Self Help is approved. This shop has the proper equipment to conduct this type of work and Mr. Seagraves has been briefed.
8/2/11, WO#10449 Upgrade NIPERNET areas tested are negative for LBP.
15 Feb 11, Workorder 10055, Install Conduit. The areas that are Positive are above the area of proposed installation. The negative areas are the exact location of conduit installation.
230Lead Based Paint Samples for Facility Sample Date Room Side Quadrant Component Substrate Color Condition Pb PbErr Result
22 2/11/2013 4.58 1.03Exterior B Lower Window Parting Board Metal Off White Intact Positiv
11 2/11/2013 1.42 0.35Exterior D Lower Window Mullion Metal Off White Intact Positiv
12 2/11/2013 1.61 0.28Exterior D Lower Window Mullion Metal Off White Intact Positiv
13 2/11/2013 1.14 0.18Exterior D Lower Window Mullion Metal Off White Intact Positiv
14 2/11/2013 1.55 0.27Exterior B Lower Window Mullion Metal Off White Intact Positiv
15 2/11/2013 1.53 0.56Exterior B Lower Window Mullion Metal Off White Intact Positiv
16 2/11/2013 2.75 0.4Exterior B Lower Window Mullion Metal Off White Intact Positiv
17 2/11/2013 1.62 0.35Exterior B Lower Window Mullion Metal Off White Intact Positiv
18 2/11/2013 2.71 0.7Exterior B Lower Window Mullion Metal Off White Intact Positiv
19 2/11/2013 0.03 0.06Exterior B Lower Window Pane Glass Off White Intact Negativ
230Lead Based Paint Samples for Facility Sample Date Room Side Quadrant Component Substrate Color Condition Pb PbErr Result
10 2/11/2013 0 0Exterior D Lower Window Glass Off White Intact negativ
21 2/11/2013 0 0Exterior B Lower Window Pane Glass Off White Intact Negativ
33 2/11/2013 0.48 0.14Interior B Lower Window Mullion Metal Off White Intact Positiv
23 2/11/2013 3.19 0.63Exterior B Lower Window Parting Board Metal Off White Intact Positiv
24 2/11/2013 0.09 0.02Interior B Lower Window Casing Metal Off White Intact Positiv
25 2/11/2013 0.2 0.06Interior B Lower Window Casing Metal Off White Intact Positiv
26 2/11/2013 1.63 0.47Interior Breakroom B Lower Window Casing Metal Off White Intact Positiv
27 2/11/2013 3.32 0.74Interior B Lower Window Casing Metal Off White Intact Positiv
28 2/11/2013 0 0Interior B Lower Window Pane Glass Off White Intact Negativ
29 2/11/2013 0 0Interior B Lower Window Pane Glass Off White Intact Negativ
30 2/11/2013 0 0Interior B Lower Window Mullion Metal Off White Intact Negativ
31 2/11/2013 0 0Interior B Lower Window Mullion Metal Off White Intact Negativ
32 2/11/2013 0.4 0.03Interior B Lower Window Mullion Metal Off White Intact Positiv
20 2/11/2013 0 0Exterior B Lower Window Pane Glass Off White Intact Negativ
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
12782_230_RenovationProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 502 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 1704937_PLM
Date Amended: 3/15/2017
Date Reported: 3/10/2017
Date Received: 3/9/2017
Lab Order ID: 1704937
None Detected
230-PINS-
001-B-001 - A
Pipe Insulation; Black; Gran;
Storage mastic
Black Non Fibrous Homogeneous
Dissolved1704937PLM_1
Other 100%
None Detected
230-PINS-
001-B-001 - B
Pipe Insulation; Black; Gran;
Storage foam glass
Black Non Fibrous Homogeneous
Crushed1704937PLM_41
Other 100%
None Detected
230-PINS-
001-B-002 - A
Pipe Insulation; Black; Gran;
Storage wrap/mastic
White, Black Fibrous Heterogeneous
Dissolved, Ashed1704937PLM_2
Cellulose Fiber Glass
Other 30% 10%
60%
None Detected
230-PINS-
001-B-002 - B
Pipe Insulation; Black; Gran;
Storage foam glass
Black Non Fibrous Homogeneous
Crushed1704937PLM_42
Other 100%
None Detected
230-PINS-
001-B-003 - A
Pipe Insulation; Black; Gran;
Storage mastic
Black Non Fibrous Homogeneous
Dissolved1704937PLM_3
Other 100%
None Detected
230-PINS-
001-B-003 - B
Pipe Insulation; Black; Gran;
Storage foam glass
Black Non Fibrous Homogeneous
Crushed1704937PLM_43
Other 100%
None Detected
230-
WLMAS-
001-B-004
Yellow/Tan Adhesive;
Restroom
Tan Non Fibrous Homogeneous
Ashed1704937PLM_4
Other 100%
None Detected
230-
WLMAS-
001-B-005
Yellow/Tan Adhesive;
Restroom
Tan Non Fibrous Homogeneous
Ashed1704937PLM_5
Other 100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Megan Javonovich (54)
P-F-002 r15 1/15/2018
All floor mastics under Vinyl Floor tiles are Positive for Asbestos Containing materials The sink undercoating is Positive for Asbestos Containing materials
EPA Method: 600/R-93/116 and 600/M4-82-020
12782_230_RenovationProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 502 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 1704937_PLM
Date Amended: 3/15/2017
Date Reported: 3/10/2017
Date Received: 3/9/2017
Lab Order ID: 1704937
None Detected
230-
WLMAS-
001-B-006
Yellow/Tan Adhesive;
Restroom
Tan Non Fibrous Homogeneous
Ashed1704937PLM_6
Other 100%
3% Chrysotile
230-
SINKUNC-
001-B-007
Black; Gran; Restroom Black Non Fibrous Homogeneous
Dissolved1704937PLM_7
Other 97%
Not Analyzed
230-
SINKUNC-
001-B-008
Black; Gran; Restroom
1704937PLM_8
Not Analyzed
230-
SINKUNC-
001-B-009
Black; Gran; Restroom
1704937PLM_9
None Detected
230-WLSH-
001-B-0010
Off White; Chalky; Storage 2 White Non Fibrous Homogeneous
Crushed1704937PLM_10
Cellulose Other 10% 90%
None Detected
230-WLSH-
001-B-0011
Off White; Chalky; Storage White Non Fibrous Homogeneous
Crushed1704937PLM_11
Cellulose Other 10% 90%
None Detected
230-WLSH-
001-B-0012
Off White; Chalky; Storage White Non Fibrous Homogeneous
Crushed1704937PLM_12
Cellulose Other 10% 90%
None Detected
230-WLPL-
001-B-0013
Gray Cementitious; Other debris; Storage 2
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_13
Other Quartz
60% 40%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Megan Javonovich (54)
P-F-002 r15 1/15/2018
EPA Method: 600/R-93/116 and 600/M4-82-020
12782_230_RenovationProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 502 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 1704937_PLM
Date Amended: 3/15/2017
Date Reported: 3/10/2017
Date Received: 3/9/2017
Lab Order ID: 1704937
None Detected
230-WLPL-
001-B-0014
Gray Cementitious; Other debris; Storage 2
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_14
Other Quartz
60% 40%
None Detected
230-WLPL-
001-B-0015
Gray Cementitious; Other debris; Storage 2
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_15
Other Quartz
60% 40%
None Detected
230-CLPL-
001-B-0016
Off White; Gran gray;
Cementitious;Storage 2
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_16
Other Quartz
60% 40%
None Detected
230-CLPL-
001-B-0017
- A
Off White; Gran gray;
Cementitious;Storage 2 pink layer
Pink Non Fibrous Homogeneous
Crushed, Teased1704937PLM_17
Other 100%
None Detected
230-CLPL-
001-B-0017
- B
Off White; Gran gray;
Cementitious;Storage 2 grey layer
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_44
Other Quartz
60% 40%
None Detected
230-CLPL-
001-B-0018
Off White; Gran gray;
Cementitious;Storage 2
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_18
Other Quartz
60% 40%
None Detected
230-FLVCT-
001-B-0019
- A
Floor Tiles and mastics;Supply grey tile
Gray Non Fibrous Homogeneous
Dissolved1704937PLM_19
Other 100%
6% Chrysotile
230-FLVCT-
001-B-0019
- B
Floor Tiles and mastics;Supply mastic 1
Black Non Fibrous Homogeneous
Dissolved1704937PLM_45
Other 94%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
12782_230_RenovationProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 502 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 1704937_PLM
Date Amended: 3/15/2017
Date Reported: 3/10/2017
Date Received: 3/9/2017
Lab Order ID: 1704937
None Detected
230-FLVCT-
001-B-0019
- C
Floor Tiles and mastics;Supply white tile
White Non Fibrous Homogeneous
Dissolved1704937PLM_46
Other 100%
6% Chrysotile
230-FLVCT-
001-B-0019
- D
Floor Tiles and mastics;Supply mastic 2
Black Non Fibrous Homogeneous
Dissolved1704937PLM_47
Other 94%
None Detected
230-FLVCT-
001-B-0020
- A
Floor Tiles and mastics;Supply grey tile
Gray Non Fibrous Homogeneous
Dissolved1704937PLM_20
Other 100%
Not Analyzed
230-FLVCT-
001-B-0020
- B
Floor Tiles and mastics;Supply mastic 1
1704937PLM_48
None Detected
230-FLVCT-
001-B-0020
- C
Floor Tiles and mastics;Supply white tile
White Non Fibrous Homogeneous
Dissolved1704937PLM_49
Other 100%
Not Analyzed
230-FLVCT-
001-B-0020
- D
Floor Tiles and mastics;Supply mastic 2
1704937PLM_50
None Detected
230-FLVCT-
001-B-0021
- A
Floor Tiles and mastics;Supply grey tile
Gray Non Fibrous Homogeneous
Dissolved1704937PLM_21
Other 100%
Not Analyzed
230-FLVCT-
001-B-0021
- B
Floor Tiles and mastics;Supply mastic 1
1704937PLM_51
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
12782_230_RenovationProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 502 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 1704937_PLM
Date Amended: 3/15/2017
Date Reported: 3/10/2017
Date Received: 3/9/2017
Lab Order ID: 1704937
None Detected
230-FLVCT-
001-B-0021
- C
Floor Tiles and mastics;Supply white tile
White Non Fibrous Homogeneous
Dissolved1704937PLM_52
Other 100%
Not Analyzed
230-FLVCT-
001-B-0021
- D
Floor Tiles and mastics;Supply mastic 2
1704937PLM_53
None Detected
230-CLGL-
001-B-0022
Off White; Brown Fibers;
Office
Tan Fibrous Homogeneous
Ashed1704937PLM_22
Cellulose Other 95% 5%
None Detected
230-CLGL-
001-B-0023
Off White; Brown Fibers;
Office
Tan Fibrous Homogeneous
Ashed1704937PLM_23
Cellulose Other 95% 5%
None Detected
230-CLGL-
001-B-0024
Off White; Brown Fibers;
Office
Tan Fibrous Homogeneous
Ashed1704937PLM_24
Cellulose Other 95% 5%
None Detected
230-CLGL-
001-B-0025
White; Gray; Fibrous; Laser Gray Fibrous Homogeneous
Ashed1704937PLM_25
Cellulose Fiber Glass
Perlite Other
40% 30%
20% 10%
None Detected
230-CLSH-
001-B-0026
Off White Chalky; Office drywall & paint only
White Non Fibrous Homogeneous
Crushed1704937PLM_26
Cellulose Fiber Glass
Other 10% 5%
85%
None Detected
230-CLSH-
001-B-0027
Off White Chalky; Supply 2 drywall: none detect; joint compnd: none detect
White Non Fibrous Heterogeneous
Crushed1704937PLM_27
Cellulose Fiber Glass
Other 5% 3%
92%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
12782_230_RenovationProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 502 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 1704937_PLM
Date Amended: 3/15/2017
Date Reported: 3/10/2017
Date Received: 3/9/2017
Lab Order ID: 1704937
None Detected
230-CLSH-
001-B-0028
Off White Chalky; Supply 1 drywall only
White, Pink Non Fibrous Homogeneous
Crushed1704937PLM_28
Cellulose Fiber Glass
Other 10% 5%
85%
None Detected
230-CLTX-
001-B-0029
Off White; gran; Supply 1 White, Tan Non Fibrous Heterogeneous
Crushed1704937PLM_29
Other Vermiculite
70% 30%
None Detected
230-CLTX-
001-B-0030
Off White; gran; Supply 2 White, Tan Non Fibrous Heterogeneous
Crushed1704937PLM_30
Other Vermiculite
80% 20%
None Detected
230-WLPL-
001-B-0031
Gray; Cementitious;
Mechanical
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_31
Other Quartz
70% 30%
None Detected
230-WLPL-
001-B-0032
Gray; Cementitious;
Mechanical
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_32
Other Quartz
70% 30%
None Detected
230-WLPL-
001-B-0033
Gray; Cementitious;
Mechanical
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_33
Other Quartz
70% 30%
None Detected
230-PINS-
001-B-0034
White Jacket; Yellow Insulation; Mechanical wrap on fiberglass
White, Silver Fibrous Heterogeneous
Ashed1704937PLM_34
Cellulose Fiber Glass
Other 60% 10%
30%
None Detected
230-PINS-
001-B-0035
White Jacket; Yellow Insulation; Mechanical wrap on fiberglass
White, Silver Fibrous Heterogeneous
Ashed1704937PLM_35
Cellulose Fiber Glass
Other 60% 10%
30%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
12782_230_RenovationProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 502 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 1704937_PLM
Date Amended: 3/15/2017
Date Reported: 3/10/2017
Date Received: 3/9/2017
Lab Order ID: 1704937
None Detected
230-PINS-
001-B-0036
White Jacket; Yellow Insulation; Mechanical wrap on fiberglass
White, Silver Fibrous Heterogeneous
Ashed1704937PLM_36
Cellulose Fiber Glass
Other 60% 10%
30%
None Detected
230-WLJ-
001-B-0037
Off White; Chalky;
joint compound only
White Non Fibrous Homogeneous
Crushed1704937PLM_37
Other 100%
None Detected
230-WLJ-
001-B-0038
- A
Off White; Chalky;
drywall; no joint compound
White Non Fibrous Homogeneous
Crushed1704937PLM_38
Cellulose Other 10% 90%
None Detected
230-WLJ-
001-B-0038
- B
Off White; Chalky;
cementitious material
Gray Non Fibrous Heterogeneous
Crushed1704937PLM_54
Other Quartz
70% 30%
None Detected
230-WLJ-
001-B-0039
Off White; Chalky;
drywall only
White Non Fibrous Homogeneous
Crushed1704937PLM_39
Cellulose Other 10% 90%
None Detected
230-WGLZ-
001-B-0040
Gray; Cementitious; Restroom Gray Non Fibrous Homogeneous
Crushed1704937PLM_40
Other 100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
1'['- Atl",, --r Lab Order ID: -11_-'.(1CtT1~.Ll::::J:..:J...L.
Client Code: _ ______
Relinquished by Dateffime Edward L. Vogel
03108/2017 1600
Received by
Accepted
Dateffime
A-F.(II7EXP~
o
Scientific Analytical Institute Lab Use Ollly 4604 Dundas Dr. Greensboro, Ne 27407liMI Phone: 336.292.3888 Fax: 336.292.3313
Company Omtact Information I Contact: Edward Vogel .
Address: 1651 5th Street West
Company: 502 CES/CEIE Phone DlI: 210·652-3605
FaxD:
Email Q/j: edward.vogel@us.afrr il
J Billingllnvoice Information Turn Around Times
90 Min.Company: Same 48 Hours D
Contact:
D
3 Hours D 72 Hours D
Address: 6 Hours 96 Hours D
12 Hours D
D
120 Hours 0 144+Houn; D24 Hours []I www.sailab.comlab@saifab.com
Asbestos Test Types
PLM EPA 600/R-93/ 116 (PLM) 0 _.. . ' - - - . - -- - --.. -- -----_.--- .
Positive slOp []I
PLM Point Count 4QO (PT4) D
PLM Poinl Count 1000 (PTM) D
PCM NIOSH 7400-A Rules (PCM) D
B Rules (PCB) 0 TWA (PTA) 0
TEM AHERA (AHEJ D
TEM Levell! (Ll!) D
TEM NIOSH 7402 (TNI) D
TEM Bulk Qualitative (TBl) D
TEM Bulk Chatfield (TBS) D
TEM Su lk Quantitative (TBQ) D
TEM Wipe ASTM D6480-05 D
TEM Mjerovae ASTM 05755-09 D
TEM Wate; EPA 100.2 (TWI) D
Other. D
PO Number:
Project Name!Number: 12782_230~Renovation
Sam~leID # .
230-PDNS-001-B-001
Description/Location Pipe Tnswation; Black; Gran; Storage
Volume! Area Comments
Positive Stop
Positive Stop
Positive SLOp
POSitive Stop
230-PINS-OO I-B-002
230-PDNS-00 I-B-003
230-WLMAS-001-B-004
230-WLMAS-OOI -B-OOS
230-WLMAS-OOI -B-006
230-SfNKUNC-ooI-B-OC
230-SINKUNC-00I-B-0 8
230-SINKUNC-OOI -B-OO
230-WLSH-00I-B-00IO
Pipe Insulalion; Black; Gran; Storage
Pipe rnsulation; Blade; Gran; Storage
YellowlTan Adhesive, Restroom
Yellow/Tan Adhesive; Restroom
Yellow/Tan Adhesive; Restroom
Black; Gran; Restroom
Black; Gran; Restroom
Black; Gran; Restroom
Off White; Chalky; Storage 2
I
230-WLSH-001-B-00Il Off White; Chalky; Storage
Total # of Samples 40_
)BSA Randolph TX 78150
F~r., V""-' mailto:www.sailab.comlab@saifab.com mailto:edward.vogel@us.afrr www.saifab.comfab@saifab.com
Lab Use Only• 1'/ D/W :;:1.1Scientific Analytical Institute Lab Order ID: \ l - \ - \ "":
" -~ 4604 Dundas Dr. Greensboro, He 27407 Client Code: ____~_Phone: 336.292.3888 Fax: 336.292.3313
Volume!Area CommentsSample ID # i)escription/Location 230-WLSH-00I-B-0012 Off White; Chalky, Storage
GrayCementitiolL<;; Other debris: Storage 2 Positive Stop 230-WLPL-OOI -B-OOlJ
"Gray Cementitious; Other debris; Storage 2230-WLPL-OOI-B-OO 14
"Gray Cementitious; Other debris; Storage 2230-WLPL-00I-B-00IS
Off White; Gran gray. Cernentitious;Storage 2 Positive Stop 2JO-CLPL-OOI-B-OO 16
OffWhhe; Gran gray; Cemeutitious;Storage 2 230-CLPL-00 I-B-0017 "
"Off White; Gran gray. Cementitious;$[orage 2230-CLPL-001 -B-0018
Floor Tiles and mastics;$upply 2 Positive Stop230-FLVCT -001-B-0019
-Floor Tiles and mastics;Supply 2230-FLVCT-00I-B-0020
"Floor Tiles and masticsj$upply I230-FL vcr-001-B-0021
Off White; Brown Fibers; Office230-CLGL-001-B-0022 Positive Stop
"OffWhire; Brown Fibers; Office 230-CLGL-001-B-0023
-Off White; Brown Fibers; Office
2J0-CLGL-00I - B-0025
230-CLGL-001-B-0024
White; Gray; Fibrous; Laser
230-CLSH-00 1-B-0026 off White Chalky; Office Positive Stop
230-CLSH -00 1-8-0027 OffWhite Chalky; Office
Off White Chalky; Office "230-CLSH -00 1-B-0028
230-CLTX-001-B-0029 Off White; gran; Supply I
230-CL TX-001-B-0030 OffWhitej gran; Supply 2
Gray; Cementilions; Mechanical230-WLPL-00I -B-0031 Positive Stop
Gray; CemenUtlous; Mechanical "230-WLPL-OOI-B-OO32
"230-WLPL-00I -B-00J3 Gray; Cementitious; Mechanical
230-PINS-OO1-B-0034 White Jacket; Yellow Insulation; Mechanical Positive Sl~
230-PINS-001 -B-0035 White Jacket; YeUow Insulation; Mechanical
230- PINS-001-8-0036 White Jacket; Yellow InsuIaUooi Mechanical
230-WL)-001-B-0037 Off While; Chalky; Laser Positive Stop
Off Whil e; Chalky; Storage 2
230-WL)-001-B-0039
230-WLJ-001-B-0038
Off While; Chalky;Slorage 2 - 230-WGLZ-00I-B-0040 Gray; Cementitious; Restroom
Page _2 of 2 AT-Ol7 W : I'T-'r-IT mailto:www.saifab.comfab@saifab.com
379_11148;
Date Received: 11/8/2012
Date Reported: 11/8/2012
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: Edward Vogel Analysis ID: 1218324PLM
Customer: 902 CES/CEAN 1651 5th Street West Randolph AFB, TX 78150
3-WGLZ-0011-
B-001
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_1
100% Other
None Detected
3-WGLZ-0011-
B-002
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_2
100% Other
None Detected
3-WGLZ-0011-
B-003
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_3
100% Other
None Detected
3-WGLZ-0011-
B-004
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_4
100% Other
None Detected
3-WGLZ-0011-
B-005
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_5
100% Other
None Detected
3-WGLZ-0011-
B-006
Hangar doors south; window glazing
White Non Fibrous Homogeneous
Crushed1218324PLM_6
100% Other
None Detected
208-WLSH-
004-B-001
Room 35; sheetrock; west White Non Fibrous Heterogeneous
Crushed1218324PLM_7
2% Cellulose 98% Other
None Detected
208-WLSH-
004-B-002
Room 35; sheetrock; west White Non Fibrous Heterogeneous
Crushed1218324PLM_8
3% Cellulose 97% Other
None Detected
Nathaniel…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .