This is a site plan drawing for the MBTA Quincy Adams Security System Enhancement project located at the Quincy Adams MBTA Garage Site in Quincy, Massachusetts. The drawing details the installation of temporary office and restroom trailers at the garage facility, with the primary security enhancement scope marked in red and blue. The project includes the installation of five AXIS P4707-PLVE cameras equipped with T94N02D pendant kits positioned at various locations around the trailer perimeter—three cameras on the rear with pendant kits and pendant mounts, and two cameras on the front with pendant kits and wall mounts. The security system enhancement also requires the replacement of an existing rackmounted security network switch ("MBTA-QAS-SES-1S1-SW-01-82.16") with an Extreme ISW-24W-4X (24-port) switch, coordinated with MBTA Signal & Systems Engineering & Maintenance (S&EM) for configuration. The project includes extensive conduit routing specifications, with rigid galvanized steel (RGS) conduit sized at minimum 3/4 inch and Category 6 (CAT6) cable runs ranging from 1 to 7 cables depending on conduit location and size, penetrating through concrete walls and into the existing Security Equipment Structure (SES) enclosure via 1.25-inch RGS conduit.

The drawing specifies that all camera heights shall match existing devices on the garage ground level, and contractors are required to field verify the exact routing of proposed conduit prior to installation. The scope of work is limited to items shown in red and blue, with all other linework considered out of scope for security purposes. Coordination is required with MBTA S&EM and the trailer tenant regarding exact cable penetration locations and conduit transitions around structural beams. The project includes infrastructure modifications such as removal of wheel barriers as needed for trailer installation, relocation of bolted chairs and trash cans, maintenance of existing handicapped parking spaces and access aisles, and installation of jersey barriers for trailer tie-down with fencing and gating at the utility zone.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REMOVE WHEEL BARRIERS AS

REQ'D FOR TRAILER INSTALL

OFFICE TRAILER;

BOD: TRIUMPH 12X64

OFFICE TRAILER

RESTROOM TRAILER,

TO BE PROCURED BY MBTA.

BOD: THE THRONE DEPOT

ADA/3-STATION RESTROOM TRAILERJERSEY BARRIERS

JERSEY BARRIER FOR

TRAILER TIE-DOWN

FENCE W/ GATE

AT UTILITY ZONE

MAINTAIN EXISTING HC PARKING SPACES, ACCESS AISLES, CURB

CUTS & WHEEL BARRIERS, TYP AT ALL HC SPACES THIS ZONE

COORDINATE CONDUIT PENETRATION

SEALING AT EXISTING CONSTRUCTION,

REFER TO E-DWG & T-DWG

RELOCATE BOLTED CHAIRS &

TRASH CANS AS REQ'D

MASSACHUSETTS PORT AUTHORITY

EAST BOSTON, MASSACHUSETTS 02128

PROJECT LOCATION:

MPA CONTRACT NO.: LOCATION CODE:

PROJECT SUBMISSION PHASE:

REGISTRATION STAMP:

KEY PLAN:

PRIMARY:

CONSULTANT:

PROJECT NUMBER AND TITLE:

SHEET TITLE:

DISCIPLINE:

DRAWN

BY:

CHECKED BY: APPROVED BY:

DATE:SCALE:

SHEET NUMBER:

DESIGNED

BY:

AS NOTED

L1630-D1 2700

PROJECT

NORTH

CARDINAL

NORTH

C:\Users\mcgee\Documents\24043_Quincy Adams_Temporary Terminal_Trailers_R24_mcgeeGKEPS.rvt 4/15/2026 10:04:20 AM

BURGIN PKWY & CENTRE ST, QUINCY,

MA, 02169

PROGRESS DRAWINGS

24043

TRAILERS AT QUINCY ADAMS MBTA

GARAGE

SITE PLAN

04/15/26

A1.10 1" = 30'-0"1

SITE PLAN

REV.

NO. DATE DESCRIPTION BY

DRAFT

trifonp Rectangle trifonp Line trifonp Line trifonp Line trifonp Line trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Typewritten Text

WS

trifonp Rectangle trifonp Callout

EXISTING SES ENCLOSURE.

REPLACE EXISTING RACKMOUNTED SECURITY NETWORK SWITCH "MBTA-QAS-SES-1S1-SW-01-82.16"

WITH EXTREME ISW-24W-4X (24-PORT).

COORDINATE WITH MBTA S&EM FOR SWITCH CONFIGURATION.

trifonp Rectangle trifonp Line trifonp Rectangle trifonp Line trifonp Line trifonp Line trifonp Rectangle trifonp Rectangle trifonp Rectangle trifonp Rectangle trifonp PolyLine trifonp Line trifonp Callout

PENETRATE CONDUIT INTO TRAILER WITH (1) CAT6 FOR WORKSTATION

COORDINATE EXACT LOCATION WITH MBTA S&EM AND TRAILER TENANT

trifonp Line trifonp Rectangle trifonp Callout

AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND PENDANT

(RECOMMEND T91B50)

"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER REAR-SOUTH END-DUAL-VIEW1 AND VIEW2"

trifonp Callout

3/4" RGS WITH (1) CAT6

trifonp Callout

3/4" RGS WITH (2) CAT6

trifonp Callout

(4) CAT6 IN 1" RGS

trifonp Callout

(1) CAT6 IN 3/4" RGS

trifonp Callout

(2) CAT6 IN 3/4" RGS

trifonp Callout

DISCUSS TRANSITION AROUND STRUCTURAL BEAM

trifonp Callout

CORE THROUGH CONCRETE WALL ADJACENT TO EXISTING CONDUITS.

DROP DOWN AND PENETRATE EXISTING SES ENCLOSURE WITH 1.25" RGS CONDUIT

trifonp Typewritten Text

SECURITY NOTES:

1. SECURITY SCOPE IS SHOWN IN RED AND BLUE. OTHER LINEWORK SHALL BE CONSIDERED OUT OF SCOPE FOR SECURITY.

2. CAMERA HEIGHT SHALL MATCH EXISTING DEVICES ON GARAGE GROUND LEVEL.

3. PROPOSED CONDUIT ROUTING IS SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING.

4. ALL CONDUIT SHALL BE RGS SIZED 3/4" MINIMUM.

trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Arrow trifonp Arrow trifonp Line trifonp Rectangle trifonp Line trifonp PolyLine trifonp Callout

(6) CAT6 IN 1.25" RGS

trifonp Callout

(7) CAT6 IN 1.25" RGS

trifonp Rectangle trifonp Callout

AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND PENDANT

(RECOMMEND T91B50)

"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER REAR-MID-DUAL-VIEW1 AND VIEW2"

trifonp Callout

AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND PENDANT

(RECOMMEND T91B50)

"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER REAR-NORTH END-DUAL-VIEW1 AND VIEW2"

trifonp Callout

AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND WALL MOUNT

(RECOMMEND T91D61)

"QAS-GARAGE L1-EAST SIDE-TRAILER FRONT-NORTH END-DUAL-VIEW1 AND VIEW2"

trifonp Callout

3/4" RGS WITH (3) CAT6

trifonp Callout

AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND WALL MOUNT

(RECOMMEND T91D61)

"QAS-GARAGE L1-EAST SIDE-TRAILER FRONT-MID-DUAL-VIEW1 AND VIEW2"

trifonp Callout

AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND WALL MOUNT

(RECOMMEND T91D61)

"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER FRONT-SOUTH END-DUAL-VIEW1 AND VIEW2"