About this file
This is a site plan drawing for the MBTA Quincy Adams Security System Enhancement project located at the Quincy Adams MBTA Garage Site in Quincy, Massachusetts. The drawing details the installation of temporary office and restroom trailers at the garage facility, with the primary security enhancement scope marked in red and blue. The project includes the installation of five AXIS P4707-PLVE cameras equipped with T94N02D pendant kits positioned at various locations around the trailer perimeter—three cameras on the rear with pendant kits and pendant mounts, and two cameras on the front with pendant kits and wall mounts. The security system enhancement also requires the replacement of an existing rackmounted security network switch ("MBTA-QAS-SES-1S1-SW-01-82.16") with an Extreme ISW-24W-4X (24-port) switch, coordinated with MBTA Signal & Systems Engineering & Maintenance (S&EM) for configuration. The project includes extensive conduit routing specifications, with rigid galvanized steel (RGS) conduit sized at minimum 3/4 inch and Category 6 (CAT6) cable runs ranging from 1 to 7 cables depending on conduit location and size, penetrating through concrete walls and into the existing Security Equipment Structure (SES) enclosure via 1.25-inch RGS conduit.
The drawing specifies that all camera heights shall match existing devices on the garage ground level, and contractors are required to field verify the exact routing of proposed conduit prior to installation. The scope of work is limited to items shown in red and blue, with all other linework considered out of scope for security purposes. Coordination is required with MBTA S&EM and the trailer tenant regarding exact cable penetration locations and conduit transitions around structural beams. The project includes infrastructure modifications such as removal of wheel barriers as needed for trailer installation, relocation of bolted chairs and trash cans, maintenance of existing handicapped parking spaces and access aisles, and installation of jersey barriers for trailer tie-down with fencing and gating at the utility zone.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REMOVE WHEEL BARRIERS AS
REQ'D FOR TRAILER INSTALL
OFFICE TRAILER;
BOD: TRIUMPH 12X64
OFFICE TRAILER
RESTROOM TRAILER,
TO BE PROCURED BY MBTA.
BOD: THE THRONE DEPOT
ADA/3-STATION RESTROOM TRAILERJERSEY BARRIERS
JERSEY BARRIER FOR
TRAILER TIE-DOWN
FENCE W/ GATE
AT UTILITY ZONE
MAINTAIN EXISTING HC PARKING SPACES, ACCESS AISLES, CURB
CUTS & WHEEL BARRIERS, TYP AT ALL HC SPACES THIS ZONE
COORDINATE CONDUIT PENETRATION
SEALING AT EXISTING CONSTRUCTION,
REFER TO E-DWG & T-DWG
RELOCATE BOLTED CHAIRS &
TRASH CANS AS REQ'D
MASSACHUSETTS PORT AUTHORITY
EAST BOSTON, MASSACHUSETTS 02128
PROJECT LOCATION:
MPA CONTRACT NO.: LOCATION CODE:
PROJECT SUBMISSION PHASE:
REGISTRATION STAMP:
KEY PLAN:
PRIMARY:
CONSULTANT:
PROJECT NUMBER AND TITLE:
SHEET TITLE:
DISCIPLINE:
DRAWN
BY:
CHECKED BY: APPROVED BY:
DATE:SCALE:
SHEET NUMBER:
DESIGNED
BY:
AS NOTED
L1630-D1 2700
PROJECT
NORTH
CARDINAL
NORTH
C:\Users\mcgee\Documents\24043_Quincy Adams_Temporary Terminal_Trailers_R24_mcgeeGKEPS.rvt 4/15/2026 10:04:20 AM
BURGIN PKWY & CENTRE ST, QUINCY,
MA, 02169
PROGRESS DRAWINGS
24043
TRAILERS AT QUINCY ADAMS MBTA
GARAGE
SITE PLAN
04/15/26
A1.10 1" = 30'-0"1
SITE PLAN
REV.
NO. DATE DESCRIPTION BY
DRAFT
trifonp Rectangle trifonp Line trifonp Line trifonp Line trifonp Line trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Arrow trifonp Typewritten Text
WS
trifonp Rectangle trifonp Callout
EXISTING SES ENCLOSURE.
REPLACE EXISTING RACKMOUNTED SECURITY NETWORK SWITCH "MBTA-QAS-SES-1S1-SW-01-82.16"
WITH EXTREME ISW-24W-4X (24-PORT).
COORDINATE WITH MBTA S&EM FOR SWITCH CONFIGURATION.
trifonp Rectangle trifonp Line trifonp Rectangle trifonp Line trifonp Line trifonp Line trifonp Rectangle trifonp Rectangle trifonp Rectangle trifonp Rectangle trifonp PolyLine trifonp Line trifonp Callout
PENETRATE CONDUIT INTO TRAILER WITH (1) CAT6 FOR WORKSTATION
COORDINATE EXACT LOCATION WITH MBTA S&EM AND TRAILER TENANT
trifonp Line trifonp Rectangle trifonp Callout
AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND PENDANT
(RECOMMEND T91B50)
"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER REAR-SOUTH END-DUAL-VIEW1 AND VIEW2"
trifonp Callout
3/4" RGS WITH (1) CAT6
trifonp Callout
3/4" RGS WITH (2) CAT6
trifonp Callout
(4) CAT6 IN 1" RGS
trifonp Callout
(1) CAT6 IN 3/4" RGS
trifonp Callout
(2) CAT6 IN 3/4" RGS
trifonp Callout
DISCUSS TRANSITION AROUND STRUCTURAL BEAM
trifonp Callout
CORE THROUGH CONCRETE WALL ADJACENT TO EXISTING CONDUITS.
DROP DOWN AND PENETRATE EXISTING SES ENCLOSURE WITH 1.25" RGS CONDUIT
trifonp Typewritten Text
SECURITY NOTES:
1. SECURITY SCOPE IS SHOWN IN RED AND BLUE. OTHER LINEWORK SHALL BE CONSIDERED OUT OF SCOPE FOR SECURITY.
2. CAMERA HEIGHT SHALL MATCH EXISTING DEVICES ON GARAGE GROUND LEVEL.
3. PROPOSED CONDUIT ROUTING IS SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING.
4. ALL CONDUIT SHALL BE RGS SIZED 3/4" MINIMUM.
trifonp Rectangle trifonp Ellipse trifonp Ellipse trifonp Rectangle trifonp Arrow trifonp Arrow trifonp Line trifonp Rectangle trifonp Line trifonp PolyLine trifonp Callout
(6) CAT6 IN 1.25" RGS
trifonp Callout
(7) CAT6 IN 1.25" RGS
trifonp Rectangle trifonp Callout
AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND PENDANT
(RECOMMEND T91B50)
"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER REAR-MID-DUAL-VIEW1 AND VIEW2"
trifonp Callout
AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND PENDANT
(RECOMMEND T91B50)
"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER REAR-NORTH END-DUAL-VIEW1 AND VIEW2"
trifonp Callout
AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND WALL MOUNT
(RECOMMEND T91D61)
"QAS-GARAGE L1-EAST SIDE-TRAILER FRONT-NORTH END-DUAL-VIEW1 AND VIEW2"
trifonp Callout
3/4" RGS WITH (3) CAT6
trifonp Callout
AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND WALL MOUNT
(RECOMMEND T91D61)
"QAS-GARAGE L1-EAST SIDE-TRAILER FRONT-MID-DUAL-VIEW1 AND VIEW2"
trifonp Callout
AXIS P4707-PLVE WITH T94N02D PENDANT KIT AND WALL MOUNT
(RECOMMEND T91D61)
"QAS-GARAGE L1-NORTHEAST SIDE-TRAILER FRONT-SOUTH END-DUAL-VIEW1 AND VIEW2"
File details come from the government source that posted it. Updated .