This document is the AACC Signage & Wayfinding Guidelines manual for Anne Arundel Community College, providing comprehensive specifications for the design, fabrication, and installation of signage and wayfinding systems across the institution's campus. The guidelines cover multiple sign categories including room identification signs (RM), directory and directional signs (D), informational and prohibitive signs (IP), donor and award recognition signs (DA), identity signs (ID), and campus wayfinding signage (C). The manual establishes standardized specifications for sign materials, colors, vinyl finishes, typefaces, logos, symbols, dimensions, mounting methods, and installation heights to ensure consistency and accessibility across all campus signage. The guidelines reference ADA compliance requirements, including raised braille Grade II and proper lighting specifications, and provide detailed technical drawings at various scales showing front, side, plan, and elevation views for each sign type with precise measurements and component specifications.

The document specifies materials including acrylic panels in various thicknesses, aluminum components with specific paint finishes, vinyl graphics in designated colors (referencing Pantone and Avery products), and mounting hardware such as VHB tape, screws, and brackets. Color standards are defined using Akzo Nobel paint codes and Pantone matches, with metallic silver, white, teal, and black as primary colors. Typeface selections vary by application, with exterior signage utilizing Neue Frutiger World and Knockout HTF fonts and interior signage using Futura and Ringside Condensed fonts. The guidelines establish mounting heights at 60 inches above finished floor for most interior signage and provide alternative mounting configurations for various architectural conditions including doors with sidelights, double doors, and wall surfaces. The manual serves as the authoritative design standard for all signage work at AACC and would be essential reference documentation for contractors responding to the related campus wayfinding message updates project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

v.4.2 | September 29, 2025

AACC Signage & Wayfinding Guidelines

General

Anne Arundel Community College Signage Guidelines — 2

TABLE OF CONTENTSAACC_Sign_manual_2024 TOC

19/29/2025

Sign Code Description Page Sign Code Description Pages

RM - Room Signs DA - Donor/Award Signs RM.B2 Room ID w/2 Inserts 9 DA.A1 Exterior Building Donor Recognition 54 RM.B2c Cubical ID w/2 Inserts 10 DA.A2 Interior Building Donor Recognition 55 RM.B3 Room ID w/3 Inserts 12 DA.B Department Suite / Feature Space Donor Recognition 56 RM.B4 Room ID w/4 Inserts 13 DA.C Interior Room/ Small Feature Space Donor Recognition 57 RM.B5 Room ID w/5 Inserts 14 DA.D Room Donorship Recognition 58 RM.B6 Room ID w/6 Inserts 15 DA.E LEED Award 59 RM.E Room ID 16 RM.F Insert Holder - Letter 18 ID - Identity Signs RM.F2 Insert Holder - Half Letter 19 ID.A Building ID 61 RM.H Room ID - Numeral Only (4 Numeral Max) 20 ID.B Suite/Department ID 62 RM.H2 Room ID - Numeral Only (≥ 5 Numerals) 21 ID.C Interior Dimensional Letters ID 63 RM.IU Restroom ID - Unisex 22 RM.IM Restroom ID - Men 23 C - Campus Wayfinding RM.IW Restroom ID - Women 24 C.MID-1 Primary Entry Monument 64 RM.M Emergency Control Room ID 25 C.MID-2 Secondary Entry Monument 66 RM.N Stair ID 27 C.PID-R Project ID - Retrofit 69 RM.N2 Egress Stair ID - Interior stairwell 28 C.PID-2R Project ID - Retrofit 71 RM.O Authorized Personnel Only ID 30 C.CM-R Campus Map Directory - Retrofit 73 RM.P ADA Exit ID 31 C.CM-2 Campus Map Directory 76 RM.P2 NO EXIT 33 C.LVD-R Vehicular Directional - Retrofit 78

C.LVD Vehicular Directional 80 D - Directory/Directional Signs C.SD-R Directional - Retrofit 84 D.J30 Building Directory - 30 inserts 35 C.SD Directional 86 D.J15 Level Directory/Directional - 15 inserts 36 C.SD-2R Directional - Retrofit 89 D.J10 Level Directory/Directional - 10 inserts 37 C.BID Building ID - Freestanding 92 D.K Blade ID Sign 38 C.BID-2 Building ID - Wall Mounted 93 D.L Wall Mounted Directional - 1 Line 40 C.SPD-R Single Post Directional - Retrofit 95 D.L2 Wall Mounted Directional - 2 Line 41 C.SPD Single Post Directional 97 D.L3 Wall Mounted Directional - 3 Line 42 C.SPD-2 Single Post Directional 100 D.LD Overhead Directional/Destination ID - 1 Destination 43 C.SM Smoke Free Campus Sign 102 D.LD2 Overhead Directional/Destination ID - 2 Destination 44 C.P Parking ID 105 D.CM Wall Mounted Campus Map 45 C.P2 Parking ID 106

C.RP Reserved Parking 107 IP - Informational/Prohibitive/Policy Signs IP Exterior Info Plaque 46 IP-2 Exterior Info Plaque 47 IP.E Exterior Feature Info / Donorship Recognition 48 IP.V Informational - Vertical (Security Monitoring) 50 IP.H Informational - Horizontal (AACC Wireless Zone) 51 IP.S1 No Smoking/Vaping - Decal 52 IP.S2 No Smoking/Vaping - Stanchion Sign 53

Anne Arundel Community College Signage Guidelines — 3

COLORS AND MATERIALS

C-01

COLORS CODE

AND SWATCH

MATCH COLOR

Akzo Nobel White Semi Gloss Grip Guard 2-part Urethane Enamel

C-02

Akzo Nobel 461-E6 Semi Gloss Grip Guard 2-part Urethane Enamel

C-03

Akzo Nobel 464-G5 Semi Gloss Grip Guard 2-part Urethane Enamel

C-04

Match to Pantone

PMS 186 C

C-05

Match to Pantone Black

C-06

VINYL CODE

AND SWATCH

MATCH COLOR

Pantone PMS Coated 7474 C

C-07

Pantone PMS Coated 5523 C

V-01

VINYL CODE

AND SWATCH

MATCH COLOR

Avery Vinyl Reflective White A7801-R

V-02

Avery Vinyl Dark Teal

SC 900-730-O

V-03

Avery Vinyl Nautical Blue

SC 900-650-O

V-04

Avery Vinyl Sunflower Yellow

SC 900-240-O

V-05

Avery Vinyl Black Matte

Anne Arundel Community College Signage Guidelines — 4

LOGOS & SYMBOLS - EXTERIOR SIGNS

ARROWS ATHLETIC LOGOS

GLYPHS

PROJECT LOGO

Campus Information Accessibility Bus Stop Restroom Food Service Book Store

Primary Mark Tertiary Mark

Public Safety & Police No Smoking No Smoking/Vaping EV Charging Station

Anne Arundel Community College Signage Guidelines — 5

LOGOS & SYMBOLS - INTERIOR SIGNS

Restroom - Women Restroom - Men Restroom - UnisexRestroom - Mylar Inserts & Blade Directionals

Mylar Inserts Only

Blade Signs Only Oversized Arrow for Single Destination Blade Signs Only

Directional Signs Straight, Then Turn U-turn

Authorized Personnel Only Stairs Security Monitoring

ARROWS

GLYPHS

PROJECT LOGOS

Anne Arundel Community College Signage Guidelines — 6

TYPEFACES - EXTERIOR SIGNS

Measure Cap Height

T-01

T-02

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Neue Frutiger World - Bold

EXTERIOR WAYFINDING

EXTERIOR BUILDING LETTERING AND DONOR NAME LETTERING

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Neue Frutiger World - Regular

T-03 ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Helvetica LT Pro Black Condensed

T-04 ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Knockout HTF30 Juniorwelterweight

T-05 ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Knockout HTF50 JUNIORWELTERWEIGHT

Anne Arundel Community College Signage Guidelines — 7

TYPEFACES - INTERIOR SIGNS

Measure Cap Height

T-06

T-07

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Futura BT Cond Medium - Condensed Medium

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Futura PT Cond - Bold

T-08 ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Futura PT Cond - Extra Bold

T-09 ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890!@#$%&* Ringside Condensed - Bold

INTERIOR WAYFINDING

INTERIOR DONOR NAME LETTERING

RM - Room Signs

Anne Arundel Community College Signage Guidelines — 8

RM SIGNS

TYPICAL MOUNTING

TYPICAL MOUNTING @ DOOR

Scale: 3/8” = 1’-0”

MOUNTING W/ NO ROOM ON

EITHER SIDE OF DOOR

Scale: 3/8” = 1’-0”

MOUNTING @ DOOR W/ SETBACK

Scale: 3/8” = 1’-0”

TYPICAL MOUNTING

@ DOOR W/SIDELIGHT

Scale: 3/8” = 1’-0”

TYPICAL MOUNTING

@ DOUBLE DOORS

Scale: 3/8” = 1’-0” NOTE: Mount sign of hardware side of double doors If hardware is on both doors, then place sign on either side of door prioritizing visibility

Robert Clark grgre

Director

Robert Clark grgre

Director

Robert Clark grgre

Director

" A

.F.

F.

to to p of th e hi gh es t l in e of b ra ill e

" A

.F.

F.

to to p of th e hi gh es t l in e of b ra ill e

3"

3"

3"

3"

" A

.F.

F.

to to p of th e hi gh es t l in e of b ra ill e

CL

EQ. EQ.

Anne Arundel Community College Signage Guidelines — 9

SIDE

RM.B2

Room ID w/2 Inserts

FRONT

Scale: Half Size

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

Single occupant o�ce, Classroom, or O�ce Suite:

• 1st line insert: Occupant Name, Class Type (“Math Lab”), or Department Name

• 2nd line insert: (indented) Title, NA, or Hours

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. 7/8”h visible window for 1”h slot opening with 15/16”h x 8-1/2”w mylar printed clear insert with black copy

5. Mount to wall with VHB tape

Robert Clark

Director

2 3

8 1/2"

9"

1/2"

5"

1 /

2"

1 / 2"

5 /

8" 1"

1 / 8"

1" 1 /

4"

8 1/2"

5 / 8"

1 1 /4

1/8" 1/16"

3/8"

5"

7 / 8"

7 / 8"

5 / 8"

7 /

1"

Anne Arundel Community College Signage Guidelines — 10

RM.B2c Cubicle ID w/2 Inserts Mounted to Cubicle Partition

FRONT

Scale: Half Size

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

Single occupant cubicle:

• 1st line insert: Occupant Name, Class Type (“Math Lab”), or Department Name

• 2nd line insert: (indented) Title, NA, or Hours

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. 7/8”h visible window for 1”h slot opening with 15/16”h x 8-1/2”w mylar printed clear insert with black copy

5. Break-form bent alum. cubical mounting bracket w/metallic silver paint finish attached to back face of sign w/ VHB tape

Robert Clark

Director

2 3 15

8 1/2" 1/2"

5" 1 /

2"

5 /

8" 1"

1 / 8"

1" 1 /

4"

8 1/2"

5 / 8"

1 1 /4

3/8"

5"

3" Mounting Bracket

9"

1 /

2"

5 / 8"

7 /

Anne Arundel Community College Signage Guidelines — 11

RM.B2c Cubicle ID w/2 Inserts Mounted to Cubicle Partition

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. 7/8”H visible window for 1”H slot opening with 15/16”h x 8-1/2” mylar printed clear insert with black copy

5. Break-form bent alum. cubical mounting bracket w/metallic silver paint finish attached to back face of sign w/ VHB tape

SIDE

Scale: Half Size

IMAGE REFERENCE

1/8" 1/16"

2"

3"

Anne Arundel Community College Signage Guidelines — 12

SIDE

RM.B3

Room ID w/3 Inserts

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

Single occupant o�ce, or O�ce Suite:

• 1st line insert: Occupant Name, or O�ce Suite

• 2nd line insert: (indented) Title, Extended department name

• 3rd line insert: (indented) Department name, Hours

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. 7/8”h visible window for 1”h slot opening with 15/16”h x 8-1/2”w mylar printed clear insert with black copy

5. Mount to wall with VHB tape

FRONT

Scale: Half Size

Vickie Cone

Distance Learning and

Information Resource Librarian

2 3 1

8 1/2" 1/2"

1 /

8" 1 /

2"

5 /

8" 1"

1" 1"

8 1/2"

5 / 8"

1 1 /4

1 / 8"

1 / 4"

1/8" 1/16"

3/8"

9"

7 / 8"

7 / 8"

7 / 8"

1 /

8"6 5 /

8" 5 / 8"

7 /

Anne Arundel Community College Signage Guidelines — 13

SIDE

RM.B4

Room ID w/4 Inserts

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

Double occupant o�ce:

• 1st line insert: Occupant Name

• 2nd line insert: (indented) Title

• 3rd line insert: Occupant Name

• 4th line insert: (indented) Title

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. 7/8”h visible window for 1”h slot opening with 15/16”h x 8-1/2”w mylar printed clear insert with black copy

5. Mount to wall with VHB tape

FRONT

Scale: Half Size

323 / 322A Robert Clark

Director

Robert Clark Director

2 3 1

8 1/2" 1/2"

1 /

4" 1 /

2"

5 /

8" 1"

1" 1"

1"

8 1/2"

5 / 8"

1 1 /8

1 / 8"

1 / 4"

1/8" 1/16"

3/8"

9"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

1 /

4"7 3 /

4"

5 / 8"

7 /

Anne Arundel Community College Signage Guidelines — 14

SIDE

RM.B5

Room ID w/5 Inserts

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

Multi occupant o�ce or classroom:

• Any Combination of Occupant Name, Occupant Title, Class Type, Department Name, or Hours where multiple lines of messages are needed.

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. 7/8”h visible window for 1”h slot opening with 15/16”h x 8-1/2”w mylar printed clear insert with black copy

5. Mount to wall with VHB tape

FRONT

Scale: Half Size

Reference Work Room Circulation Workroom Technical Services Interlibrary Loans

2 3 1

8 1/2" 1/2"

3 /

8" 1 /

2"

5 /

8" 1"

1" 1"

1" 1"

8 1/2"

5 / 8"

1 1 /4

1 / 8"

1 / 4"

1/8" 1/16"

3/8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

3 /

8"

9"

7 /

8"

5 / 8"

Anne Arundel Community College Signage Guidelines — 15

SIDE

RM.B6

Room ID w/6 Inserts

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

Multi occupant o�ce or classroom:

• Any Combination of Occupant Name, Occupant Title, Class Type, Department Name, or Hours where multiple lines of messages are needed.

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. 7/8”h visible window for 1”h slot opening with 15/16”h x 8-1/2”w mylar printed clear insert with black copy

5. Mount to wall with VHB tape

FRONT

Scale: Half Size

Reference Work Room Circulation Workroom Technical Services Interlibrary Loans

2 3 1

8 1/2" 1/2"

1 /

2" 1 /

2"

5 /

8" 1"

1" 1"

1" 1"

1"

8 1/2"

5 / 8"

1 1 /4

1 / 8"

1 / 4"

1/8" 1/16"

3/8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

7 / 8"

1 /

2"

9"

5 /

Anne Arundel Community College Signage Guidelines — 16

SIDE

RM.E

Room ID

FRONT

Scale: Half Size

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

For rooms with permanent room usage.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers and message

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

220A

VENDING

2 3 1

8 1/2" 1/2"

5" 1 /

2"

8 1/2"

1 1 /4

1/8" 1/16"

3/8"

5"

5 / 8"

9"

1 /

Anne Arundel Community College Signage Guidelines — 17

RM.E

Room ID - Typical Layouts

TYPICAL LAYOUTS

Scale: 3” = 1’-0”

220A

VENDING

ELECTRICAL ROOM

MECHANICAL ROOM

TELECOM ROOM

ELEVATOR MACHINE ROOM

CHECK IN AT MAIN ENTRY

Anne Arundel Community College Signage Guidelines — 18

SIDE

RM.F

Insert Holder - Letter

FRONT

Scale: 1:3

Usage

For use when a printed letter insert is needed to display information related to classes and events. Typical at all classrooms.

Notes

1. 1/16” thick matte clear acrylic panel with 1/4” masked and painted black boarder to conceal adhesion to back panel.

2. .030“ thick vinyl filler to create window slot for custom 8.5” x 11“ paper insert

3. 1/8” thick acrylic backer panel with black paint finish

4. Inset finger groove on front panel NOTE: Thumb groove can be located on the most accessible side depending on architectural condition

5. Mount to wall with VHB tape

6. Mount top edge of sign flush to bottom edge of room sign and align right justified to room sign

TYPICAL

LOCATION

Scale: 1 1/2” = 1’

Robert Clark

Director

GUEST

LECTURE SERIES

TIMES:

8 AM - 9 AM

10 AM - 11 AM

NOON - 1 PM

2 PM - 3 PM

4 PM - 5 PM

MONDAY - THURSDAY

A

LI

G N9"

1 /

2"

1"

1/4" 1/4"

1 / 4"

1 / 4"

1/16" .030"

1/8"

Anne Arundel Community College Signage Guidelines — 19

RM.F2

Insert Holder - Half Letter

FRONT

Scale: 1:3

TYPICAL

LOCATION

Scale: 1 1/2” = 1’

LOCATION

@ DOUBLE

OCCUPANCY

OFFICE

Scale: 1 1/2” = 1’

Usage

For use when a printed half letter insert is needed to display information related to classes and events. Install two (stacked) at each double occupancy faculty o�ces for printed schedules.

Notes

1. 1/16” thick matte clear acrylic panel with 1/4” masked and painted black boarder to conceal adhesion to back panel.

2. .030“ thick vinyl filler to create window slot for custom 8.5” x 5.5“ paper insert

3. 1/8” thick acrylic backer panel with black paint finish

4. Inset finger groove on front panel NOTE: Thumb groove can be located on the most accessible side depending on architectural condition

5. Mount to wall with VHB tape

6. Mount top edge of sign flush to bottom edge of room sign and align right justified to room sign

SIDE

Robert Clark

Director

323 / 322A Robert Clark

Director

Robert Clark Director

Testing in Progress

PLEASE BE CONSIDERATE

1"

A

LI

G N

A

LI

G N

9"

6"

1/4"

1 / 4"

1 / 4"

1/4"

1/16"

Anne Arundel Community College Signage Guidelines — 20

SIDE

RM.H

Room ID - Numeral Only (4 Numeral Max)

FRONT

Scale: Half Size

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

This sign type is typically installed at closets, storage rooms, custodial rooms.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

302A

1/8" 1/16"

3/8"

3"

4"

3"

1/4"

4" 1/4"

3 / 4"

1 /

4"

4 1/4"

1 3 /8

Anne Arundel Community College Signage Guidelines — 21

SIDE

RM.H2

Room ID - Numeral Only (≥ 5 Numerals)

FRONT

Scale: Half Size

Usage

Room signs identify rooms and provided essential information about the rooms function, aiding navigation.

They can indicate room names, functions, occupancy status, and can some instances provide directional guidance.

This sign type is typically installed at closets, storage rooms, custodial rooms.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

2002L

2 1 1/8" 1/16"

3/8"

3"

1/4"

8 1/2" 1/4"

3 / 4"

3"

8 1/2"

8 3/4"

1 /

4"

1 3

Anne Arundel Community College Signage Guidelines — 22

RM.IU

Restroom ID - Unisex

Usage

Restroom signs indicate the location of restrooms, ensuring accessibility and safety for everyone.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers, message, glyph and rule.

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

SIDEFRONT

Scale: Half Size

UNISE X

1/8" 1/16"

1/2"

5 / 8"

5 / 8"

1 / 8"

1 /

2"

6 1/2"

6" 1/2"

6"

1 /

1 / 2"

9"

Anne Arundel Community College Signage Guidelines — 23

RM.IM

Restroom ID - Men

Usage

Restroom signs indicate the location of restrooms, ensuring accessibility and safety for everyone.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers, message, glyph and rule.

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

SIDEFRONT

Scale: Half Size

MEN

1/8" 1/16"

1/2"

5 / 8"

5 / 8"

1 /

2" 1 /

8"

1 /

2"

6 1/2"

6" 1/2"

6"

1 / 2"

Anne Arundel Community College Signage Guidelines — 24

RM.IW

Restroom ID - Women

Usage

Restroom signs indicate the location of restrooms, ensuring accessibility and safety for everyone.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers, message, glyph and rule.

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

SIDEFRONT

Scale: Half Size

WOMEN

1/8" 1/16"

1/2"

5 / 8"

5 / 8"

1 /

2" 1 /

8"

1 /

2"

6 1/2"

6" 1/2"

6"

1 / 2"

Anne Arundel Community College Signage Guidelines — 25

RM.M

Emergency Control Room ID

Usage

Emergency Control Room ID signs clearly and easily identify the location of the emergency control rooms to ensure rapid and e�ective emergency response.

Notes

1. 1/8” thick acrylic panel with direct-to-surface printed graphics

2. Mount to wall with VHB tape

SIDEFRONT

Scale: Half Size

1/8"

6"

8 1/2"

Anne Arundel Community College Signage Guidelines — 26

RM.M

Emergency Control Room ID

TYPICAL LAYOUTS

Scale: 1:3

TYPICAL MOUNTING @ DOOR

Scale: 3/8” = 1’-0”

TYPICAL STAND ALONG MOUNTING

Scale: 3/8” = 1’-0”

Robert Clark grgre

Director

1 / 2"

" A

.F.

F.

A

LI

G N

Anne Arundel Community College Signage Guidelines — 27

SIDE

RM.N

Stair ID

FRONT

Scale: Half Size

Usage

Stair ID signs provide clear and consistent information about egress stairwells, particularly for emergency responders and building occupants, aiding in navigation and safe evacuation during emergencies.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers, messages and glyph

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

RM.N sign shall be mounted on both sides of stairway door for stairwells that connect 3 or less levels.

If the egress stairway connects more than three levels, a RM.N shall be mounted on the exterior side of door and a RM.N2 shall be mounted on the interior landing of the stairwell.

STAIR A

LEVEL 1

2 3 1

8 1/2" 1/2"

5" 1 /

2"

8 1/2"

1/8" 1/16"

3/8"

5"

7 /

7 /

1" 1 7

/8

1"

9"

Anne Arundel Community College Signage Guidelines — 28

RM.N2

Egress Stair ID - Interior stairwell

FRONT

Scale: 3” = 1’

SIDE

Usage

Stair ID signs provide clear and consistent information about egress stairwells, particularly for emergency responders and building occupants, aiding in navigation and safe evacuation during emergencies.

Notes

1. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers and messages

2. ADA compliant grade II raised braille

3. Mount to wall with VHB tape and silicone

Stair egress signs are required within interior of egress stairways that connect more than three levels 2

LEVEL

NO ROOF ACCESS

LEVELS 1-4

EXIT ON LEVEL 1

STAIR A

1'-0"

1'- 6"

1/8"

1" 5"

1 1 /2

Anne Arundel Community College Signage Guidelines — 29

RM.N2

Egress Stair ID - Interior stairwell ICC Code Reference

TYPICAL MOUNTING @ DOOR

Scale: 3/8” = 1’-0”

TYPICAL MOUNTING @ STAIR LANDING

Scale: 3/8” = 1’-0”

L E V EL

N O R O O F AC C E S S

L E V EL S 1 - 4

E X I T O N L E V EL 1

S TA IR A

L E V EL

N O R O O F AC C E S S

L E V EL S 1 - 4

E X I T O N L E V EL 1

S TA IR A

" A

.F.

F.

" A

EQ. EQ.

1023.9 Stairway identification signs.

A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than three stories designating the floor level, the terminus of the top and bottom of the interior exit stairway and ramp and the identification of the stairway or ramp. The signage shall state the story of and direction to the exit discharge, and the availability of roof access from the interior exit stairway and ramp for the fire department. The sign shall be located 5 feet (1524 mm) above the floor landing in a position that is readily visible when the doors are in the open and closed positions. In addition to the stairway identification sign, a floor-level sign in visual characters, raised characters and braille complying with ICC A117.1 shall be located at each floor-level landing adjacent to the door leading from the interior exit stairway and ramp into the corridor to identify the floor level.

1023.9.1 Signage requirements.

Stairway identification signs shall comply with all of the following requirements:

1. The signs shall be a minimum size of 18 inches (457 mm) by 12 inches (305 mm).

2. The letters designating the identification of the interior exit stairway and ramp shall be not less than 11/2 inches (38 mm) in height.

3. The number designating the floor level shall be not less than 5 inches (127

mm) in height and located in the center of the sign.

4. Other lettering and numbers shall be not less than 1 inch (25 mm) in height.

5. Characters and their background shall have a non-glare finish. Characters shall contrast with their background, with either light characters on a dark background or dark characters on a light background.

6. Where signs required by Section 1023.9 are installed in the interior exit stairways and ramps of buildings subject to Section 1025, the signs shall be made of the same materials as required by Section 1025.4.

Anne Arundel Community College Signage Guidelines — 30

SIDE

RM.O

Authorized Personnel Only ID

FRONT

Scale: Half Size

Usage

The primary purpose of an "Authorized Personnel Only" sign is to restrict access to a specific area to individuals who are authorized to be there, ensuring safety and security.

This sign type is typically installed at all Telecom Rooms and areas designated as restricted access.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers, messages and glyph

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

5. Red 1/16” raised ADA compliant glyph

AUTHORIZED

PERSONNEL

ONLY

2 5

1/8" 1/16"

3/8"

6" 1/2"

1/2" 6"

1 1 /2

3 /

4"

6" 1 /

2"

6"

6 1/2"

Anne Arundel Community College Signage Guidelines — 31

SIDE

RM.P

ADA Exit ID

FRONT

Scale: Half Size

Usage

ADA exit signs provide clear and accessible directions to emergency exits, ensuring that individuals with disabilities can safely evacuate a building during an emergency.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant numbers and messages

3. ADA compliant grade II raised braille

4. Mount to wall with VHB tape

EXIT

ONLY

1/8" 1/16"

3/8"

6" 1/2"

1/2" 6"

6"

6"

1 1 /4

1 / 2"

1 /

6 1/2"

Anne Arundel Community College Signage Guidelines — 32

RM-P

ADA Exit ID

TYPICAL LAYOUTS

Scale: 1:3

EXIT

EXIT

ROUTE

EXIT

ONLY

Anne Arundel Community College Signage Guidelines — 33

SIDE

RM.P2

NO EXIT

FRONT

Scale: Half Size

Usage

A “No Exit” sign indicates that a door, pathway, or area is not an exit route and should not be used as such, especially during an emergency evacuation.

Notes

1. 1/8” thick red acrylic panel with white 1/16” raised ADA compliant numbers and messages

2. ADA compliant grade II raised braille

3. Mount to wall with VHB tape

NO

EXIT

1/8" 1/16"

3/8"

6"

6"

1 3

D - Directory/Directional Signs

Anne Arundel Community College Signage Guidelines — 34

D WALL DIRECTORY / DIRECTIONAL SIGNS

TYPICAL MOUNTING

TYPICAL MOUNTING D.J30

Scale: 3/8” = 1’-0”

TYPICAL MOUNTING D.J15

Scale: 3/8” = 1’-0”

TYPICAL MOUNTING D.J10

Scale: 3/8” = 1’-0”

FOURTH FLOOR

Rooms 400 - 418 Computer Lab 404 Restrooms 405/407 Classrooms 406 - 410 Response Center 414 Rooms 419 - 426 Conference Room 419 IDEA Lab 422 IDEA Lab O�ces 426 Production Studios 423 Computer Lab 423 Conference Room 423 Break Room 423 Huddle Room 423

FOURTH FLOOR

Rooms 400 - 418 Computer Lab 404 Restrooms 405/407 Classrooms 406 - 410 Response Center 414 Rooms 419 - 426 Conference Room 419 IDEA Lab 422 IDEA Lab O�ces 426 Production Studios 423

" A

.F.

F.

CL

" A

.F.

F.

CL

" A

.F.

Anne Arundel Community College Signage Guidelines — 35

D.J30 Building Directory - 30 (MAX) insert

Usage

Building directory signs guide individuals to specific classrooms, o�ces, departments, and other key destinations within a building to reduce confusion and minimize the time spent searching for destinations.

This sign type is typically placed within an entry lobby, an interior space near a building entry, an interior connection between two buildings or a ground level elevator.

Notes

1. 1/2” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel

3. Direct-to-surface printed black messages

4. Black accent bar

5. Recessed slots with printed mylar message inserts

6. Mount to wall with screws, drywall anchors and chrome finished screw caps

SIDEFRONT

Scale: 1 1/2” = 1’

CADE Center for Fine Arts

FIRST FLOOR

SECOND FLOOR

Rooms 102 -130 Restrooms Classrooms 102 Response Center 104

Conference Room 201 IDEA Lab 204 IDEA Lab O�ces 205 Production Studios 205 Computer Lab 208 Conference Room 210 Break Room 223 Huddle Room 224

Conference Room 301 IDEA Lab 304 IDEA Lab O�ces 305 Production Studios 305 Computer Lab 308 Conference Room 310

THIRD FLOOR

1"

1"

1 / 4"

2"

1"

1"

1"

1 3 /4

2 1/2"

2'-6" 1/16" 1/8" 1/2"

4' -2

1 / 4"

5 / 8"

3 / 4"

2 3

Anne Arundel Community College Signage Guidelines — 36

D.J15 Level Directory/Directional - 15 inserts

Usage

Level directory signs guide individuals to specific classrooms, o�ces, departments, and other key destinations within a given floor to reduce confusion and minimize the time spent searching for destinations.

This sign type is typically placed near elevators or landings from open stair connections between floors.

Notes

1. 1/2” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel

3. Direct-to-surface printed black messages

4. Black accent bar

5. Recessed slots with printed mylar message inserts

6. Mount to wall with screws, drywall anchors and chrome finished screw caps

FRONT

Scale: 1 1/2” = 1’

SIDE

FOURTH FLOOR

Rooms 400 - 418 Computer Lab 404 Restrooms 405/407 Classrooms 406 - 410 Response Center 414 Rooms 419 - 426 Conference Room 419 IDEA Lab 422 IDEA Lab O�ces 426 Production Studios 423 Computer Lab 423 Conference Room 423 Break Room 423 Huddle Room 423

2 3 1'-10" 1"

1"

1 / 4"

1 1 /2

2"

1"

/1

6" 1"

2 1/2" 1"

3' -2

1 3 /4

1/16" 1/8" 1/2"

Anne Arundel Community College Signage Guidelines — 37

D.J10 Level Directory/Directional - 10 inserts

Usage

Level directory signs guide individuals to specific classrooms, o�ces, departments, and other key destinations within a given floor to reduce confusion and minimize the time spent searching for destinations.

This sign type is typically placed near elevators or landings from open stair connections between floors.

Notes

1. 1/2” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel

3. Direct-to-surface printed black messages

4. Black accent bar

5. Recessed slots with printed mylar message inserts

6. Mount to wall with screws, drywall anchors and chrome finished screw caps

FRONT

Scale: 1 1/2” = 1’

SIDE

FOURTH FLOOR

Rooms 400 - 418 Computer Lab 404 Restrooms 405/407 Classrooms 406 - 410 Response Center 414 Rooms 419 - 426 Conference Room 419 IDEA Lab 422 IDEA Lab O�ces 426 Production Studios 423

2 3 1'-10" 1"

2' -5

1 / 4"

1"

1 / 4"

1 1 /2

2"

1"

/1

6" 1"

2 1/2" 1"

1 3 /4

1/16" 1/8" 1/2"

Anne Arundel Community College Signage Guidelines — 38

D.K Blade ID Sign

Usage

Blade signs are used is to increase visibility of destinations in corridors by projecting outward and perpendicular to the flow of tra�c. They are designed to be easily seen by individuals guiding them to a major destination.

Notes

1. 1/4” thick black acrylic panel

2. 1/8” thick alum. panel with metallic silver paint finish

3. Matte black vinyl messages

4. Mount to wall with 1”x 1”alum. “L” brackets with metallic silver paint finish, screws, drywall anchors and metallic finished screw caps

SIDE A

Scale: 3” = 1’

PLAN

Scale: 3” = 1’

SIDE B

Scale: 3” = 1’

ELEVATORS ELEVATORS

14 2 3

1"

1"

1 / 8"

1 / 4"

1'- 1 1

/2

1 / 2"

1'- 1 1

/2

11"

10 1/2"

1 3 /4

1 / 2"

10"

1/2"

Anne Arundel Community College Signage Guidelines — 39

D.K Blade ID Sign

TYPICAL MOUNTING HEIGHT

Scale: 3/8” = 1’

TYPICAL LAYOUTS

Scale: 1 1/2” = 1’

W A

LL

M

O U

N T

W A

LL

M

O U

N T

PRODUCTION

STUDIOS

PRODUCTION

STUDIOS

RESTROOMSRESTROOMS

A B

A B

W A

LL

M

O U

N T

ELEVATORS ELEVATORS

A B

" A

Anne Arundel Community College Signage Guidelines — 40

D.L Wall Mounted Directional 1 Line

Usage

Wall Mounted Directional signs guide individuals to specific classrooms, o�ces, departments, by room number, similar to an address system.

This sign type is typically placed at decision points along interior corridors.

Notes

1. 1/2” thick acrylic sign panel w/ black paint finish

2. 1/8” thick acrylic sign panel w/ metallic silver paint finish

3. Matte black vinyl messages

4. Pin-mount with minimal gap to wall surface

FRONT

Scale: 3” = 1’

SIDE

Scale: 3” = 1’

TYPICAL MOUNTING

Scale: 3/8” = 1’-0”

Rooms 304-329

1 2 3

Rooms 304-329

1"

1" 1 7

/8

1/4" 1/2"

1'-9"

1'-9" 1"

1" 3"

1 1 /8

1 3

/4

6"

6"

1 /

2"

" A

F

Anne Arundel Community College Signage Guidelines — 41

D.L2 Wall Mounted Directional 2 Line

Usage

Wall Mounted Directional signs guide individuals to specific classrooms, o�ces, departments, by room number, similar to an address system.

This sign type is typically placed at decision points along interior corridors.

Notes

1. 1/2” thick acrylic sign panel w/ black paint finish

2. 1/8” thick acrylic sign panel w/ metallic silver paint finish

3. Matte black vinyl messages

4. Pin-mount with minimal gap to wall surface

FRONT

Scale: 3” = 1’

SIDE

Scale: 3” = 1’

TYPICAL MOUNTING

Scale: 3/8” = 1’-0”

Rooms 148-160 Rooms 190-172

1 2 3

Rooms 148-160 Rooms 190-172

8" 1"

1" 1 7

/8

1/4" 1/2"

1'-9"

8"

1 1 /8

1 3

/4

3 /

4"

1'-9" 1"

1" 3"

5 / 8"

3 / 4"

" A

F

Anne Arundel Community College Signage Guidelines — 42

D.L3 Wall Mounted Directional 3 Line

Usage

Wall Mounted Directional signs guide individuals to specific classrooms, o�ces, departments, by room number, similar to an address system.

This sign type is typically placed at decision points along interior corridors.

Notes

1. 1/2” thick acrylic sign panel w/ black paint finish

2. 1/8” thick acrylic sign panel w/ metallic silver paint finish

3. Matte black vinyl messages

4. Pin-mount with minimal gap to wall surface

FRONT

Scale: 3” = 1’

SIDE

Scale: 3” = 1’TYPICAL MOUNTING

Scale: 3/8” = 1’-0”

Rooms 216-212 Rooms 218-220 Rooms 231-236

1 2 3

Rooms 216-212 Rooms 218-220 Rooms 231-236

1"

1" 1 7

/8

1/4" 1/2"

1 1 /8

1 3

/4

1'-9" 1"

1" 3"

5 / 8"

3 / 4"

1'-9"

" A

.F.

F

"8"

Anne Arundel Community College Signage Guidelines — 43

D.LD

Overhead Directional/Destination ID- 1 Destination

Usage

An overhead directional sign guides individuals to their destinations, particularly in large or complex open spaces, by providing clear and easily visible directions.

Notes

1. 1/2” thick black acrylic backer panel

2. Bracket screws into black panel and is covered white acrylic panel

3. White 1/4” thick acrylic adhered to black panel with VHB tape

4. Matte black vinyl messages

5. 1" x 1" x 1/8" thick alum. angle mounting bracket with white paint finish

6. Recessed 1/8" area in backer for bracket

7. Mechanically fasten mounting bracket to ceiling with toggle bolts

NOTE: For long messages, sign width should only be wide enough to accommodated messages. Verify the sign width will fit within the intended space and verify the sign will leave a minimum clearance of 6’-8” from bottom of sign to finished floor before fabrication.

FRONT

Scale: 1 1/2” = 1’

SIDE

Half Scale

BACK

Scale: 1 1/2” = 1’

LECTURE HALL

LECTURE HALL

1 / 4"

4" 1 /

2"

1/4" 1/2"

1 / 4"

2'-6" (Varies)

2"5 1/2"

2" 5 1/2"

2"

Anne Arundel Community College Signage Guidelines — 44

D.LD2

Overhead Directional/Destination ID- 2 Destinations

Usage

An overhead directional sign guides individuals to their destinations, particularly in large or complex open spaces, by providing clear and easily visible directions.

Notes

1. 1/2” thick black acrylic backer panel

2. Bracket screws into black panel and is covered white acrylic panel

3. White 1/4” thick acrylic adhered to black panel with VHB tape

4. Matte black vinyl messages

5. 1" x 1" x 1/8" thick alum. angle mounting bracket with white paint finish

6. Recessed 1/8" area in backer for bracket

7. Mechanically fasten mounting bracket to ceiling with toggle bolts

NOTE: For long messages, sign width should only be wide enough to accommodated messages. Verify the sign width will fit within the intended space and verify the sign will leave a minimum clearance of 6’-8” from bottom of sign to finished floor before fabrication.

FRONT & BACK

Scale: 1 1/2” = 1’

SIDE

Half Scale

DESTINATIONDESTINATION

1 / 4"

4" 1 /

2"

1/4" 1/2"

2" 2" 2" 2"

2"

4'-4" (Varies)

1 /

2"

4"

Anne Arundel Community College Signage Guidelines — 45

SIDE

D.CM

Wall Mounted Campus Map

FRONT

Scale: 1:3

Usage

Campus maps help individuals understand their current location within the entire campus and how di erent areas relate to each other.

This sign type is typically placed within an entry lobby, an interior space near a building entry, an interior connection between two buildings.

Notes

1. 1/16” thick matte clear acrylic panel with 1/4” masked and painted black boarder to conceal adhesion to back panel.

2. .030“ thick vinyl filler to create window slot for custom 8.5” x 11“ paper insert

3. 1/8” thick acrylic backer panel with black paint finish

4. Inset finger groove on front panel NOTE: Thumb groove can be located on the most accessible side depending on architectural condition

5. 1/8” thick metallic silver acrylic panel with black 1/16” raised ADA compliant messages

6. Mount to wall with VHB tape

7. Digitally printed letter size paper campus map insert (AACC prints and inserts map internally)

CAMPUS MAP

1"

9"

1 /

2"

1 / 4"

3 /

4"

1 / 2"

7 / 8"

3 / 8"

1 1 /4

8 1/2"

1/4"

1 1 /4

1/8"

1/16"

IP - Informational/Prohibitive/Policy Signs

Anne Arundel Community College Signage Guidelines — 46

IP

Exterior Info Plaque

FRONT

Scale: 1 1/2” = 1’-0”

Usage

Informational signs serve to provide guidance, directions, and details about a place, or situation. They inform people about the purpose of an area, provide directions, give instructions, or warn of potential hazards.

Notes

1. Painted .080” thick aluminum panel

2. Vinyl messages and glyphs

3. Install sign to wall surface with tamper resistance countersunk screws painted to match sign panel and silicon

Please Ring Bell for Service

Monday - Friday 8am - 4pm

V-01

C-03

C-02

18"

3" 1 7

⁄8" 3"

1 1 ⁄4"

1 ⁄4

Anne Arundel Community College Signage Guidelines — 47

IP-2

Exterior Info Plaque

Usage

Informational signs serve to provide guidance, directions, and details about a place, or situation. They inform people about the purpose of an area, provide directions, give instructions, or warn of potential hazards.

Notes

1. Painted .080” thick aluminum panel

2. Vinyl messages and glyphs

3. Install sign to wall surface with tamper resistance countersunk screws painted to match sign panel and silicon

FRONT

Scale: 3” = 1’-0”

Restricted Area

Authorized Personnel Only

V-01

C-03

C-02

12"

2" 1 1

⁄4" 2"

1" 1 3

⁄8"

Anne Arundel Community College Signage Guidelines — 48

IP.E

Exterior Feature Info / Donorship Recognition

Usage

This sign can highlight exterior campus features and/or provide donorship recognition to acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

These signs are typically located near exterior features such at public art, outdoor common spaces or landscaping features.

Notes

1. 1/4” thick sign panel with paint finish on all exposed faces and returns

2. 2” dia. alum. post with paint finish

3. Concrete footer as engineered

4. Direct-to-surface printed or silk-screened graphics

5. 8” x 8” x 1/4” alum. mounting plate with paint finish welded to post

6. Attach sign panel to mounting plate with tamper resistance countersunk screws from below and paint to match post and mounting plate

FRONT

Scale: 3/4” = 1’-0”

SIDE

Scale: 3/4” = 1’-0”

Tamper resistant countersunk hardware

2"

3' -0

8" 1/4"

45°

2' -7

Anne Arundel Community College Signage Guidelines — 49

IP.E

Exterior Feature Info / Donorship Recognition

Usage

This sign can highlight exterior campus features and/or provide donorship recognition to acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

These signs are typically located near exterior features such at public art, outdoor common spaces or landscaping features.

Notes

1. 1/4” thick sign panel with paint finish on all exposed faces and returns

2. 2” dia. alum. post with paint finish

3. Concrete footer as engineered

4. Direct-to-surface printed or silk-screened graphics

5. 8” x 8” x 1/4” alum. mounting plate with paint finish welded to post

6. Attach sign panel to mounting plate with tamper resistance countersunk screws from below and paint to match post and mounting plate

PANEL DETAIL

Scale: 3” = 1’-0”

Micro Bio-Retention Meadow Grasses Pervious Paving Systems

BAY FRIENDLY, GREEN FEATURES

Landscapes and hardscapes at the Anne Arundel Community College Health and Life Sciences Building are designed to manage and reduce water pollution downstream. Bay friendly, green infrastructure o�ers a multitude of benefits beyond water quality including carbon sequestration, habitat creation and reduction of urban heat island e�ect.

These planters are designed to collect and filter excess rainwater. They are filled with plants native to low-lying areas in our region and absorb and filter rainwater. The root systems of these plants, along with the special soil mix below them, filter pollution from the water as it soaks into the ground before entering local streams and the Chesapeake Bay.

Upland meadow plantings border the bio-retention areas to provide an additional filtering layer and help to absorb and slow down the water before it enters the bio-retention areas. Meadow grasses help manage storm water runo� and provide additional habitat area.

Major walkways at the Health and Life Sciences Building are paved with pervious pavers. These pavers are separated by aggregate-filled joints and placed over a bed of stones and aggregate. Water is able to infiltrate through the joints in the pavers and is stored in the void spaces in the stones and aggregates underneath the paver surface, where it is then filtered and absorbed back into the ground.

17 1/2"

Anne Arundel Community College Signage Guidelines — 50

IP.V

Informational - Vertical (Security Monitoring)

Usage

Informational signs serve to provide guidance, directions, and details about a place, or situation. They inform people about the purpose of an area, provide directions, give instructions, or warn of potential hazards.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel

3. Direct-to-surface printed black messages and graphics

4. Mount to wall with VHB tape

FRONT

Scale: 3” = 1’-0”

1'- 6"

1 / 2"

1'-0" 1/2"

1 /

4" 5 /

8" 1 1

/4

1 / 2"

1'-

1 /

1'-0 1/2"

Anne Arundel Community College Signage Guidelines — 51

IP.H

Informational - Horizontal (AACC Wireless Zone)

Usage

Informational signs serve to provide guidance, directions, and details about a place, or situation. They inform people about the purpose of an area, provide directions, give instructions, or warn of potential hazards.

Notes

1. 1/8” thick black acrylic panel

2. 1/8” thick metallic silver acrylic panel

3. Direct-to-surface printed black messages and graphics

4. Mount to wall with VHB tape

FRONT

Scale: 3” = 1’-0”

1 /

8" 1 /

2" 3 /

4"

1'- 0"

1 / 2"

1'-6" 1/2"

1 1 /8

1'-

1 /

1'-6 1/2"

Anne Arundel Community College Signage Guidelines — 52

IP.S1

No Smoking/Vaping - Decal

Usage

No Smoking/Vaping signs clearly communicate that smoking and vaping are prohibited.

Notes

1. Digitally printed graphic on decal vinyl

2. When mounting to glass, install on second surface

FRONT

Scale: Half Size

Anne Arundel Community College Signage Guidelines — 53

IP.S2

No Smoking/Vaping - Stanchion Sign

Usage

This sign can highlight exterior campus features and/or provide donorship recognition to acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

These signs are typically located near exterior features such at public art, outdoor common spaces or landscaping features.

Notes

1. 1/4” thick sign panel with paint finish on all exposed faces and returns

2. Direct-to-surface printed or silk-screened graphics

3. Mount to existing stanchion

FRONT

Scale: 3/4” = 1’-0”

PANEL DETAIL

Scale: 3” = 1’-0”

13"

DA - Donor/Award Signs

Anne Arundel Community College Signage Guidelines — 54

DA.A1

Exterior Building Donor Recognition

Usage

Exterior donor recognition letters acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

These signs are strategically placed near entrances and along walkways to be easily visible to both pedestrians and motorists.

Notes

1. See Sign type ID.A for building ID details

2. Donor ID: 1/2” thick flat cut gloss black acrylic letters

3. Pin-mount to wall surface w/ minimal stando� and silicon adhesive

NOTE: As architectural conditions vary, the placement and sizing of lettering shall be approved by Strategic Communications and Facilities Planning & Construction to ensure the design compliments the architectural condition before fabrication.

FRONT

Scale: 1” = 1’

SIDE

Scale: 1” = 1’

ELEVATION

Scale: 1/8” = 1’

D O N O R R E C O G N I T I O N

NOTE: Maintain scale relationship and spacing between donor letters and building ID letters

" m in

” m ax

1/ 2" m in

” m ax

1/2"

Va rie s

Anne Arundel Community College Signage Guidelines — 55

DA.A2

Interior Building Donor Recognition

Usage

Donor recognition signs acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

Furthermore, these signs often highlight the impact of the donation potentially inspiring others to contribute.

These signs or features are typically located in prominent, high-tra c common areas where they are easily visible and accessible to visitors.

Notes

1. 1/4" horizontal grain brushed aluminum with satin clear coat finish

2. Etched and filled black text and rule

3. Chemically etched donor portrait

4. Pin-mount flush to wall surface

FRONT

Scale: 1 1/2” = 1’

1 3 2

ELEVATION

Scale: 1/2” = 1’

CL

" A

.F.

F.

2'-0"

1'-

Anne Arundel Community College Signage Guidelines — 56

DA.B

Department Suite / Feature Space Donor Recognition

Usage

Department Suite and feature space donor recognition signs acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

Furthermore, these signs can also provide identity for suites and featured spaces to help individuals easily find them.

These signs are typically located in prominent department suite entries or reception as well as amenity spaces such as theaters and other common spaces.

Notes

1. 1” thick fabricated brushed alum. letters

2. Pin-mount flush to wall surface

NOTE: As architectural conditions vary, the placement and sizing of lettering shall be approved by Strategic Communications and Facilities Planning & Construction to ensure the design compliments the architectural condition before fabrication.

THE SMITH FAMILY

EMERGENCY MEDICAL

SERVICES SUITE

ELEVATION

Scale: 1/2” = 1’

SIDE

Scale: 1/2” = 1’

FRONT

Scale: 1/2” = 1’ EXAMPLE REFERENCE

CL

" A

.F.

F.

1 /

4"

1 / 2"

1 /

2"

CLEQ. EQ.

6"

Anne Arundel Community College Signage Guidelines — 57

DA.C

Interior Room/ Small Feature Space Donor Recognition

Usage

Department Suite and feature space donor recognition signs acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

These signs are typically located in within the interior of smaller amenity or common spaces

Notes

1. Glass panel with silk-screened or direct-to-surface digitally printed graphics

2. Brushed silver mounting stando�

FRONT

Scale: 1 1/2” = 1’

SIDE

Scale: 1 1/2” = 1’

1 2

ELEVATION

Scale: 1/2” = 1’

CL

" A

.F.

F.

2'-0"

1'-

1 / 2"

3/8"

EXAMPLE REFERENCE

Anne Arundel Community College Signage Guidelines — 58

DA.D

Room Donorship Recognition

Usage

Room donorship recognition signs acknowledge and express gratitude to individuals, organizations, or groups who have contributed to AACC campus projects.

These signs are typically located above room ID signs.

Notes

1. 1/8” thick black acrylic panel

2. 1/16” thick metallic silver acrylic panel

3. Direct-to-surface printed black messages

4. Metallic silver vinyl messages

5. Mount to wall with VHB tape

6. Mount above room sign TYPICAL

LOCATION

Scale: 1 1/2” = 1’

SIDEFRONT

Scale: 1:3

Robert Clark

Director

1 3 2

CL1/2" 8 1/2"

1 / 2"

7" 9"

1/16" 1/8"9"

9 /

5 /

5 /

Anne Arundel Community College Signage Guidelines — 59

DA.E

LEED Award

Usage

A LEED award is to publicly recognize and showcase that a building or project has achieved LEED certification demonstrating AACC’s commitment to sustainability.

These awards are typically located within the main lobby of a highlighted LEED feature of a LEED certified building.

Notes

1. AACC supplied medallion plaque, 8” diameter

2. Brushed silver mounting stando�s

3. Clear acrylic panel with direct-to-surface digitally printed graphics

NOTE: Printed graphics vary per project

FRONT

Scale: 1” = 1’

SIDE

Scale: 1” = 1’

Energy efficiency strategies used throughout the Health and Life Science Building result in a 35% energy savings compared to a code compliant building, preventing nearly 470,000 pounds of greenhouse gases from being emitted. It would take 277 acres of forest to sequester that amount of carbon.

The Health and Life Science Building site previously housed an administration building and a pool house. Those structures were demolished and 97% of the demolition material was diverted from landfills and sent to recycling centers.

Electric vehicle charging stations and priority parking for fuel-efficient vehicles are provided in the parking lots that serve the Health and Life Science Building, reducing pollution by promoting alternatives to conventionally fueled automobiles.

The planting beds around the Health and Life Science Building include over

1.3 acres of native landscaping that provides habitat and promotes biodiversity, without the need for mowing, permanent irrigation, fertilizers, or pesticides. The site around the Health and Life Science Building provides over

1.75 acres of open space that encourages interaction with the environment and the campus community.

The Health and Life Science Building has reduced the building water usage by over 42% by installing low flow plumbing fixtures. These fixtures include low flow lavatories, urinals, and toilets, which save on water use and reduce sewage treatment needs. Exterior water use is reduced by providing drought-tolerant plants that do not require irrigation.

The Health and Life Science Building includes several strategies to promote occupant comfort and well-being by improving indoor air quality. The interior receives 30% more fresh air than a typical building; and building entrances are designed to prevent dirt and particulates from entering the building.

Materials inside the Health and Life Science Building were selected to minimize the use of harmful substances, and to promote human health. Over 25% of the materials used in the Health and Life Science Building came from responsible sources, including products with a high recycled content, salvaged materials, and FSC-certified wood. Some of these materials include the structural steel, drywall, ceilings, flooring, and metal siding.

HEALTH AND

LIFE SCIENCES

BUILDING

MATERIALS AND

RESOURCES

WATER

EFFICIENCY

SUSTAINABLE

SITES

INDOOR

ENVIRONMENTAL

QUALITY

ENERGY AND

ATMOSPHERE

LOCATION AND

TRANSPORTATION

4'-5"

3'-3 7/8"

1'- 4"

1 /

2" 3'

-6

Anne Arundel Community College Signage Guidelines — 60

DA.E

LEED Award

Notes

1. Verify all measurements on site before fabrication

2. AACC to supply LEED text content and plaque

3. Verify award location with AACC

FRONT

Scale: 1/2” = 1’

CL

CL

EQ. EQ.

" A

ID - Identity Signs

Anne Arundel Community College Signage Guidelines — 61

ID.A

Building ID

Usage

Usage

Building ID signs identify buildings and confirm destinations within a campus.

They help students, faculty, sta�, and visitors easily locate specific buildings and navigate the campus e�ciently.

These signs are strategically placed near entrances and along walkways to be easily visible to both pedestrians and motorists.

Notes

1. 1/2” thick flat cut gloss black acrylic letters

2. Pin-mount to wall surface w/ minimal stando� and silicon adhesive

NOTE: As architectural conditions vary, the placement and sizing of lettering shall be approved by Strategic Communications and Facilities Planning & Construction to ensure the design compliments the architectural condition before fabrication.

ELEVATION (FOR EXAMPLE ONLY)

Not to Scale

FRONT

Scale: 1” = 1’

SIDE

Scale: 1” = 1’

" m in

” m ax

Anne Arundel Community College Signage Guidelines — 62

A D M

IS

S

IO

N S

A D M

IS

S

IO

N S

A D M I S S I O N S

A D M

IS

S

IO

N S

ID.B

Suite/…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .