APPENDIX A-DETAILED SIMULATION LAB REQUIREMENTS.xlsx
XLSX spreadsheet 23 KB Posted
- Attached to
- 9280-25-R-IFBD-00060
- Solicitation number
- 3160007383
- Issued by
- Greene County, Mississippi
About this file
This document is Appendix A - Detailed Simulation Lab Requirements, outlining technical specifications for a comprehensive simulation lab software and hardware solution, likely for a medical training institution or healthcare education program. The requirements detail a robust system for managing medical simulation training across multiple rooms and floors, with specific focus on recording, tracking, assessing, and evaluating simulation scenarios. The solution must support eight simulation rooms and two OSCE-style rooms, with three control rooms and four debriefing rooms, fully integrating with Laerdal medical simulation products and requiring compatibility with existing hardware like Windows-based PCs and flat-screen televisions.
The proposed solution mandates a cloud-based, secure platform with extensive technical requirements including 4K camera support, real-time video synchronization, LMS integration with Canvas, mobile app availability, and comprehensive security features. Critical technical specifications include role-based access control, data encryption, privacy law compliance, ISO and accessibility standards, and the ability to track individual student usage with detailed metrics. The system must provide professional installation, comprehensive training for faculty and staff, ongoing support during business hours, and the capability to manage medical device data capture, including EKG, ultrasound, and electronic medical records (EMR). The solution requires seamless integration, scalability, and the ability to support current and future medical simulation training needs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| APPENDIX B-SIMULATION LAB EQUIPMENT LIST.docx | DOCX document | |
| RFP-COLLEGE OF NURSING AND HEALTH PROFESSIONS SIMULATION CENTER SYSTEM UPGRADE FINAL.pdf | ||
| USM RFP 25-54 LEGAL AD.pdf | ||
| download.pdf | ||
| APPENDIX C-SIMULATION EQUIPMENT EXCEL DOCUMENT.xlsx | XLSX spreadsheet | |
| APPENDIX D- CNHP SIMULATION CENTER SYSTEM UPGRADE COST WORKSHEET.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Identifier | Req/Opt | Requirements and Functions | Yes/No | Details |
| Functionality and Compatibility | ||||
| 1 | R | Must be able to effectively manage, record, debrief, and assess simulation training and medical exams on-site. | ||
| 2 | R | Must be able to effectively manage, record, debrief, and assess simulation training and medical exams in-situ. | ||
| 3 | R | Must be flexible or scalable and able to manage: | ||
| -One room | ||||
| -Many rooms | ||||
| -One floor | ||||
| -Many floors | ||||
| 4 | R | The software must maintain a detailed historical log of log in, recording, playback, and administrative changes. | ||
| 5 | O | Should be captured in a single, reliable, and secure web-based interface. | ||
| 6 | R | Must create data metrics that can be used to: | ||
| -Give Feedback | ||||
| -Debrief | ||||
| -Track Progress | ||||
| 7 | O | Data should be able to adjust to fit program level needs on an individual and cohort level consistent with training needs. | ||
| 8 | R | Must automatically track usage and outcomes to include hours spent in simulation center. | ||
| 9 | R | Must track individual student usage with a clock-in and clock-out feature, allowing students to record their time in and out of the simulation center to monitor overall hours, and support comprehensive data collection | ||
| 10 | R | Must have scalable software that is able to be expanded when additional functionalities are needed with minimal disruption to usage or activities. | ||
| 11 | O | Should include customizable: | ||
| -Roles | ||||
| -Scenarios | ||||
| -Permissions | ||||
| 12 | R | Must support medical device capture to include: | ||
| -EKG | ||||
| -Ultrasound | ||||
| -EMR | ||||
| 13 | R | Must combine psycho-motor skills practice with digital assessment and evaluation tools in peer-to-peer or individual self-driven practice. | ||
| 14 | R | Provide LMS integration with Canvas | ||
| 15 | R | Provide scheduling feature to allow spaces in the facility to be schedueld for use. | ||
| Camera and Video Specifications | ||||
| 16 | R | Each video must be recorded in its entirety in a single file regardless of session length. The file must not be broken into individual segments based on time. | ||
| 17 | R | The software must support groupings of multiple cameras together. | ||
| 18 | R | The software must support synchronized start and stop recordings of grouped cameras and the population of all cameras that are grouped within the same meta data. | ||
| 19 | R | The software must allow recording to be initiated via the user interface. A one click record button in the user interface shall start and stop the recording. | ||
| 20 | O | The software should allow student ID numbers or employee ID numbers to be associated and used to locate recordings. | ||
| 21 | R | Video recording must be avaliable immediately after recording. No rendering time shall be required in order to view a recording. | ||
| 22 | R | Must simultaneously manage and facilitate the use of multiple cameras and patient monitors. | ||
| 23 | R | In the event that multiple cameras are associated with single rooms, video content must play back completely synchronized. | ||
| 24 | O | The software should be able to create evaluation templates and forms which may be used to score and evaluate recordings. | ||
| 25 | R | Remote viewing capabilites for instructors to observe simulations in real-time without streaming to external platform | ||
| 26 | R | User friendly interface for: | ||
| -Controlling cameras | ||||
| -Viewing Feeds | ||||
| -Controlling Cameras | ||||
| 27 | R | In the event that multiple cameras are located within the same room, the user will be able to launch all camera views by clicking a single room ID. | ||
| 28 | R | The software must support all rooms being viewed simultaneously. | ||
| 29 | O | The software should include support for cameras up to 4K resolution. | ||
| 30 | R | The software must support digital pan tilt zoom on all live view cameras. | ||
| 31 | R | The software must support all cameras to be recording simultaneously along with all rooms being viewed simultaneously without loss of system performance. | ||
| 33 | O | The software should allow the ability to select preset positions for the cameras prior to recording. | ||
| 33 | O | The software should include a built-in video editor that allows the user to create video clips and save them as independent files. | ||
| Equipment/Hardware | ||||
| 34 | R | Fully integrate with existing Laerdal products, seamlessly capturing data from any Laerdal manikin and LLEAP software or include costs of full replacement. | ||
| 35 | R | Must provide detailed hardware solution based on equipment list in Appendix C for the following rooms: Simulation Rooms (Laerdal Manikin-Equipped) |
In all eight simulation rooms the A/V solution must be fully compatible with Laerdal manikin simulators—past, present, and future models—including, but not limited to: SimMom, SimBaby, SimMan3G Plus, and NursingAnne Simulator. The system must support seamless integration and real-time data capture from the manikin’s patient monitor, which operates using Laerdal Patient Monitor software on Windows-based All-in-One PCs.
OSCE-Style Rooms Two OSCE rooms must be supported and managed through the designated control infrastructure detailed throughout the requirements document.
36 R Must provide detailed hardware solution based on equipment list in Appendix C for the following rooms: Control Rooms Three separate control rooms located throughout the simulation lab must have full operational control over any connected spaces (i.e. both the Simulation Rooms and OSCE-Style Rooms). The A/V solution should enable remote control, monitoring (both audio and video), and communication capabilities for all connected spaces (Simulation Rooms and OSCE-Style rooms). Within the three control rooms, should be control stations allowing for simultaneous operation of each of the connected spaces. Furthermore, each control station should also allow for full operational control of any connected space throughout the simulation lab. Debriefing Rooms Four debriefing rooms are currently equipped with Windows-based micro form factor PCs and flat-screen televisions for remote viewing. The proposed solution must support real-time video and audio transmission to these rooms without the need for additional hardware. Compatibility with existing equipment is required.
| Implementation/Professional/Training/On-Going Support | ||
| 37 | R | Professional installation services must be provided |
| 38 | R | Comprehensive training for faculty and staff on equipment usage, troubleshooting, and maintenance must be provided in both an in-person and virtual format |
| 39 | R | The vendor must provide remote implementation support |
| 40 | R | The vendor must provide detailed implementation timelines. (Should reflect all aspects and the phases through go-live) |
| 41 | R | The vendor must provide phone, email and web support. Coverage must be available during working hours Monday through Friday, 8 to 5 Central time. Please describe user support models. |
| 42 | R | The vendor must provide after hours support upon request |
| Other/Additional Features or Functions | ||
| 43 | R | Must offer a mobile app available compatible with both iOS and Android |
| 44 | O | The application should support up to four devices as recording devices per session, ensuring seamless synchronization with cloud videos |
| 45 | R | Must store data in 100% cloud based system that can be accessed from any mobile device. |
| 46 | O | Should support ITIL. |
| 47 | R | Must support ISO 2000. |
| 48 | R | Must be 508 compliant. |
| 49 | R | Should support CMMI. |
| 50 | R | Must allow export of data to either a delimited file or CSV. |
| 51 | R | Should allow customizable session timeout capabilities. |
| 52 | R | Should have API availability to automate interface to and from other systems. |
| 53 | O | Authenticate users with SAML/SSO, Shibboleth, or Microsoft Azure Active Directory. |
| 54 | R | Must have role-based security – to allow access to services. |
| Hosted Solution Requirements | ||
| 55 | R | Must secure data in transit and at rest. If encryption of data at rest is not available, please provide alternative measures. If encryption of data is available and imposes additional cost, that cost should be reflected in the proposal. |
| 56 | R | Vendor shall have in place a system recovery plan, including policies around nightly backups and restoration and recovery of data within 24 hours of an outage or request. |
| Security, Storage and Access Control | ||
| 57 | R | Must provide centralized account management functionality (account creation, deletion, lock-outs, etc..). |
| 58 | O | Should have no restrictions on the number of users. |
| 59 | O | User permissions and access to various system functions should be role-based with users allowed in multiple roles. |
| 60 | R | User rights shall prevent other users from logging into the system and viewing a session which they have not initiated or have rights to view. |
| 61 | R | Observers, with appropriate rights, shall be able to talk to students via computer microphone or USB headset by clicking on an icon located within the video window during observation when optional talkback hardware is present. |
| 62 | R | Role-based permissions govern each user's right to add, edit, and view information within the system. There should be the capability to accomodate tiered access based on roles. |
| 63 | O | The software should allow users to search only their content that they have been given access to. |
| 64 | R | Encrypted data storage to ensure the confidentiality and integrity of recorded sessions. |
| 65 | O | Should allow the university administrator to view user data on system use, (logins, uploads, modifications, etc.). |
| 66 | O | Should provide an audit trail/logging for any action in the database, including real-time notifications. |
| 67 | O | Should provide a system capability for auditing/logging. |
| 68 | R | Must have the ability to track and display the history of information stored in the application. |
| 69 | R | Must have the ability to support current State and Federal privacy laws and general data protection (GDPR) policies. |
| 70 | R | Where applicable, shall meet ISO/IEC 40500:2012 [Web Content Accessibility Guidelines (WCAG) 2.1 AA] at a minimum. |
| 71 | R | Must have the ability to encrypt data at rest. If this capability imposes additional cost, that cost should be reflected in the proposal. |
| 72 | R | Must have the ability to segment data according to a data security model. |
| 73 | R | Must provide read-only data fields, or the prevention of overwriting certain data fields. |
| 74 | R | Must provide a method for all data imports and exports, and must use a secure file transfer such as Secure File Transfer Protocol (SFTP). |
| 75 | O | Should support integration with third-party multi-factor authentication providers. |
| 76 | O | The solution shall allow secure login leveraging SAML, Active Directory, or Shibboleth security integration and determine level of access via identified fields. |
| 77 | O | Should allow for granular role-based control of access to profile data and workflows; including full access, limited access, and view only access; based on the individual user. |
| 78 | R | Must allow the administrator to assign security roles to users. |
| 79 | O | Should not use or provide default credentials. |