Appendix 6 - SEC Label Format.xlsx
XLSX spreadsheet 25 KB Posted
- Solicitation number
- HC102821R0040
- Issued by
-
Defense Information Systems Agency
About this file
This government file contains details for a federal contract opportunity to upgrade computer room air conditioners and raised access floors at the Defense Information Systems Agency Yokota facility in Japan. The Defense Information Systems Agency is soliciting proposals to remove and replace computer room air conditioners, condensers, and upgrade the computer room layout and mechanical systems at Building 650 to support additional computer room floor space. Offerors should provide products and services to upgrade the existing infrastructure, including replacement of identified systems and components, and testing of the completed work. The performance work statement provides requirements for the mechanical and architectural modifications to the computer room.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| encl4_qasp_YOK CRAC and Raised Floor.docx | DOCX document | |
| HC102821R00400001.pdf | ||
| Amendment A0001 - HC102821R0040 - Questions_Govt Responses.docx | DOCX document | |
| Appendix 2 - Identification Labeling and Marking.pdf | ||
| Appendix 10 - MIL-STD-188-124B 18Dec2000 (SRG).pdf | ||
| HC102821R0040.pdf | ||
| Price Worksheet.xlsx | XLSX spreadsheet | |
| Appendix 5 - 23 09 23 - BACnet Direct Digital Control DDC Systems for HVAC.pdf | ||
| Payment Plan.docx | DOCX document | |
| Appendix 7 - 09 69 13 - Rigid Grid Access Flooring.docx | DOCX document | |
| Appendix 3 - 26-01 DISA Electrical Safety Program.pdf | ||
| Appendix 8 - 23 81 23.00 20 - CRAC Units.docx | DOCX document | |
| Appendix 11 - Background Check for Access Request.xlsx | XLSX spreadsheet | |
| Appendix 1 - Concept Drawings.pdf | ||
| Appendix 4 - Integrated Automation.pdf | ||
| Appendix 9 - 26-04 - Signal Reference Grid for Grounding.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Blank SEC
| UNIFORMAT Level 1-5 | Manufacture | Model No | Serial No | Bar Code | Description | Room Designator | Grid Designator | UID # | Capacity | Capacity Units | "FED FROM"/CKT # or "Parent ID" | Date Installed | Warranty Expiration Date |
| Using Uniformat Levels 1-5 as outlined in separate Spreadsheet | text 20 char | text 40 char; If no Model , use Configuration # or CO# | text 20 char; If no Serial#, then leave blank | Text 7 Characters | description | Interior: Room Number; Exterior: Name of Location (Ex: MechYard) | Alphanumeric grid location | SEC designator/Floor#, Sys designator, and Sequence #s (Ex: DP2-C-12) | Capacity of the SEC (Number) | n/a, Gal, kW, kVA, A, BTU, Ton, GPM, CFM, RPM, PSI | date DDMMYY | date DDMMYY |
Liebert FPA20C832B M11G7U0010 U510296 Computer Room Air Handler 147 CG72 PDU_1-AB-12 200 kVA
SEC Designator List
| Access Control System Panel | ACSP |
| Actuator | ACT |
| Air Compressor | AC |
| Air Conditioning Unit | ACU |
| Air Cooled Aftercooler | ACA |
| Air Dryer | AD |
| Air Handler Unit | AHU |
| Air Separator | AS |
| Air Tank (Captive) | AT |
| Automated External Defibrillator (AED) | AED |
| Automatic Transfer Switch | ATS |
| Back-Flow Preventer | BFP |
| Basin Heater | BH |
| Battery Charger | BC |
| Battery Charger Controller | BCC |
| Battery Disconnect Switch (UPS System) | BDS |
| Battery Monitoring System (UPS System) | BMS |
| Battery String (UPS System) | BAT |
| Belly Tank | BT |
| Boiler | BLR |
| Breaker | BRKR |
| Buffer Tank | BFT |
| Building Automation System Monitor | BASM |
| Building Automation System Panel | BASP |
| Capacitor | CAP |
| Central Vacuum System | CVS |
| Chemical Feed Sys Controller | CFSC |
| Chemical Feed Sys Pump | CFSP |
| Chemical Shock Feeder | CSF |
| Chilled Water Pump | CHWP |
| Chilled Water Return Pump | CHWRP |
| Chilled Water Supply Pump | CHWSP |
| Chilled Water Valve | CHWV |
| Chiller (generic, including DX) | CH |
| Chiller Compressor Starter | CHCS |
| Clean Agent Booster Panel | CABP |
| Clean Agent Control Panel | CACP |
| Clean Agent Exhaust Fan | CAEF |
| Clean Agent Intake Air Fan | CAIAF |
| Clean Agent Nitrogen Generator | CANG |
| Clean Agent Nitrogen Test | CANT |
| Clean Agent Tank | CAT |
| Cold Aisle Containment Pod | CACPD |
| Computer Room Air Conditioner | CRAC |
| Computer Room Air Handler | CRAH |
| Condenser (Cooling Tower) Water Pump | CWP |
| Condenser Return Pump | CRP |
| Condenser Return Tank | CRT |
| Condenser Return Unit | CRU |
| Condenser Water Filter | CWF |
| Condenser Water Valve | CWV |
| Contactor | CTC |
| Control Panel | CP |
| Control Panel (Critical) | UCP |
| Control Panel (Essential) | ECP |
| Controller | CTLR |
| Cooling Tower | CT |
| Cooling Tower Basin Heater | CTBH |
| Cooling Tower Pump | CTP |
| Day Tank | DT |
| Differential Pressure Transmitter | DPXMIT |
| Disconnect | DISC |
| Disconnect (Critical) | UDISC |
| Disconnect (Essential) | EDISC |
| Distribution Panel | DP |
| Distribution Panel (Critical) | UDP |
| Distribution Panel (Essential) | EDP |
| Domestic Hot Water Return Pump | DHWRP |
| Domestic Hot Water Supply Pump | DHWSP |
| Electric Meter | ELMTR |
| Electric Pallet Jack | ELJ |
| Electromagnetic Interference Filter | EMIF |
| Elevator | ELEV |
| Emergency Generator | EGEN |
| Emergency Light | EML |
| Emergency Power Off System | EPOS |
| Emergency Shower | ESHR |
| Enclosures | ENCL |
| Engine Fire Pump | ENG |
| Equipment Lift | EQLT |
| Exhaust Fan | EF |
| Exit Signs | ES |
| Expansion Tank | ET |
| Eyewash | EWASH |
| Fan Coil Unit | FCU |
| Filter | FIL |
| Fire Alarm Booster Panel | FABP |
| Fire Alarm Control Panel | FACP |
| Fire Alarm Smoke Detector | FASD |
| Fire Extinguisher | FX |
| Fire Pump | FP |
| First Aid Kit | FAK |
| Forklift | FRK |
| Fuel Monitoring System | FMS |
| Fuel Polisher | FPOL |
| Fuel Tank | FT |
| Fuel Transfer Pump | FTP |
| Furnace | F |
| Gas Meter | GMTR |
| Gate, Electric | GATE |
| Ground Bar/Rods | GNDBR |
| Grounding System | GNDSYS |
| Hard Drive Shredder | SHRDHD |
| Heat Box | HB |
| Heat Exchanger (all types) | HX |
| Heat Pump | HP |
| Heat Trace | HT |
| Heat Trace Control System | HTCS |
| Heating Coil | HC |
| Hot Tie | HTIE |
| Hot Water Pump | HWP |
| Humidifier | HUM |
| Humidifier Control Unit | HUMCU |
| Hydrogen Detection System | HDS |
| Hydrogen Detection System Controller | HDSC |
| Hydrogen Detection System Detector | HDSD |
| Ice Dispenser | ID |
| Ice Maker | IM |
| In-Row Cooler | IRC |
| Intrusion Detection System Panel | IDSP |
| Junction Box | JBOX |
| Leak Detection System Detector | LDSD |
| Leak Detection System Monitor | LDSM |
| Lighting Panel (Critical) | ULP |
| Lighting Panelboard | LP |
| Lighting Panelboard (Essential) | ELP |
| Lightning Protection System | LPS |
| Load Bank | LB |
| Loading Dock Lift | LIFT |
| Louver | LVR |
| Manual Transfer Switch | MTS |
| Masking Noise Generator | MNG |
| Meter | MTR |
| Motor Control Center | MCC |
| Motor Control Center (Critical) | UMCC |
| Motor Control Center (Essential) | EMCC |
| Motor Starter | MTRSTR |
| Outside Air Intake | OAI |
| Overhead Door | OHDR |
| Power Distribution Unit | PDU |
| Pressure Reduction Valve | PRV |
| Pump (Generic) | P |
| Raceway | RW |
| Rectifier | RECT |
| Refrigerant Detection System Detector | RDSD |
| Refrigerant Detection System Monitor | RDSM |
| Refrigerator | REFER |
| Relief Valve Pressure | RVP |
| Remote Distribution Cabinet | RDC |
| Remote Monitoring System Panel | RMSP |
| Return Fan | RF |
| Reverse Osmosis System | ROS |
| Roof Top Unit | RTU |
| Security System Detector | SSD |
| Security System Panel | SSP |
| Signal Reference Grid | SRG |
| Simulator | SIM |
| Spill Kit | SPK |
| Spill Kit Containment Shed | SPCS |
| Standby Booster Pump | SBP |
| Static Bypass Module (UPS system) | SBM |
| Static Transfer Switch | STS |
| Static Transfer Switch (Critical) | USTS |
| Strainer | STRNR |
| Substation | SUB |
| Sump/Ejector Pump | SUMP |
| Supply Fan | SF |
| Surge Protective Device | SPD |
| Switchboard | SWBD |
| Switchboard (Critical) | USWBD |
| Switchboard (Essential) | ESWBD |
| Switchgear | SWGR |
| Switchgear (Critical) | USWGR |
| Switchgear (Essential) | ESWGR |
| Temporary Generator | TGEN |
| Temporary UPS | TUPS |
| Transformer | XFMR |
| Transformer (Critical) | UXFMR |
| Transformer (Essential) | EXFMR |
| Ultra Sonic | ULTSNC |
| Ultra Sonic Flow Sensor Inlet | USFSI |
| Ultra Sonic Flow Sensor Outlet | USFSO |
| Uninterruptible Power Supply | UPS |
| Uninterruptible Static Transfer Switch | USTS |
| Unit Heater | UH |
| Utility | UTIL |
| Valve (generic) | VLV |
| Variable Air Volume | VAV |
| Variable Frequency Drive | VFD |
| Variable Refrigerant Volume | VRV |
| VESDA | VESDA |
| Water Distribution Unit | WDU |
| Water (Softener) Treatment System | WTS |
| Water Fountain | WF |
| Water Heater | WH |
| Water Meter | WMTR |
| Water Tank (generic) | WT |
| White Noise AMP | WNA |
| White Noise Equalizer | WNE |
| White Noise Generator | WNG |
SEC Sys Designator List
| System Designators | Abbreviation | Normal Feed | Field Color & | Text Color | |
| A Bus | A | A | White | Black | |
| B Bus | B | B | Blue | White | |
| Boiler | BO | BO | Orange | Black | |
| Building | BL | BL | Tan | White | |
| Building Automated System | BAS | BAS | Green | Black | x |
| C Bus | C | C | Black | White | |
| Chilled Water | CH | CH | Blue | White | x |
| Chilled Water Return | CHR | CHR | Light Blue | White | x |
| Compressed Air | CA | CA | Dark Red | White | |
| Condenser Water | CW | CW | Green | White | x |
| Condenser Water Return | CWR | CWR | Light Green | White | x |
| D Bus | D | D | Gray | Black | |
| Direct Current | DC | DC | Dark Blue | White | |
| Domestic Water | DW | DW | Light Blue | Black | |
| Dual Bus (A & B) | AB | A | Brown | White | |
| Dual Bus (B & A) | BA | B | Brown | White | x |
| Dual Bus (C & D) | CD | C | Brown | White | |
| Dual Bus (D & C) | DC | D | Brown | White | x |
| Emergency Generator | EG | EG | Black | White | |
| Emergency Lighting | EL | EL | Color Not Determined | x | |
| Fire Protection | FP | FP | Red | White | |
| Fuel Oil | FO | FO | Yellow | Black | |
| Ground | GD | GD | Dark Green | Black | x |
| Natural Gas | NG | NG | Dark Gray | White | |
| Not Installed | X | X | Light Purple | Dark Grey | x |
| PGS1 (B Bus) | E | E | Gold | White | x |
| PGS2 (A Bus) | F | F | Silver | Black | x |
| Removed | REM | REM | Light Purple | Dark Grey | x |
| Security | Purple | White | x | ||
| Steam Distribution | ST | ST | Pink | Black | |
| Ultra Sonic | ULTSNC | ULTSNC | Color Not Determined |
File details come from the government source that posted it. Updated .