J.16 Fire Alarm And Sprinkler System Device Breakdown.pdf
PDF 112 KB Posted
- Solicitation number
- AOCSSB24R0032
- Issued by
-
Architect of the Capitol
About this file
This document appears to be a list of fire alarm and sprinkler system device quantities for several federal office buildings. It provides detailed information on the types and quantities of system components such as smoke detectors, heat detectors, manual pull stations, strobes, speakers, and suppression systems installed in the Cannon, Longworth, Rayburn, Ford, and O'Neill House Office Buildings.
The related federal contract opportunity is a solicitation (AOCSSB24R0032) issued by the Architect of the Capitol (AOC) for a Blanket Purchase Agreement (BPA) for Fire Protection Systems and Equipment Testing, Inspection, Maintenance, and Development. The BPA will have a 1-year base period and 4 one-year options, for a total of 5 years. The AOC anticipates awarding 3 BPAs, with simultaneous award of the first two Call Orders. Offerors are required to price these initial Call Orders as part of their proposals. The NAICS code is 922160 - Fire Protection, and the PSC is H112 - Quality Control-Fire Control Equipment.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
System/Device Listing (initiation and notification device quantities are approximate)
.1 Cannon House Office Building – Autocall AL1500 Multiplex fire alarm system – 888,563 sqft
1. 1750 Smoke Detectors
2. 22 Heat Detectors
3. 9 Beam Detectors
4. 50 Duct Detectors
5. 123 Manual Fire Alarm Stations
6. 271 Strobes
7. 203 Speakers
8. 48 Fire Phones
9. 1 Novec Gaseous Suppression System (Garage Telecom Rm)
a. 4 Smoke Detectors
b. 3 Manual Fire Alarm Stations
c. 1 Horn
d. 6 Strobes
e. 3 Horn/Strobes
f. 1 Actuation Solenoid
10. 1 Wet Chemical Suppression System
11. 2 Fire Pumps
12. 1 Dry Pipe Sprinkler System
13. 48 Standpipe Outlets
14. Wet Pipe Sprinklers Throughout Building
.2 Longworth House Office Building – Autocall AL1500 Multiplex fire alarm system –
682,791 sqft
1. 2800 Smoke Detectors
2. 55 Heat Detectors
3. 2 Beam Detectors
4. 40 Duct Detectors
5. 70 Manual Pull Stations
6. 258 Strobes
7. 400 Speakers
8. 59 Fire Phones
9. 1 Novec Gaseous Suppression System (B204/207)
a. 46 Smoke Detectors
b. 2 Manual Fire Alarm Stations
c. 1 Horn
d. 9 Strobes
e. 7 Horn/Strobes
f. 6 Actuation Solenoids
10. 2 Wet Chemical Suppression Systems
11. 2 Fire Pumps
12. 2 Dry Sprinkler Systems
13. 60 Standpipe Outlets
14. 4 VESDA Air Sampling Smoke Detection Systems
15. Wet Pipe Sprinklers Throughout Building
16. 1 Notifier Onyx Workstation
.3 Rayburn House Office Building – Autocall AL1500 Multiplex fire alarm system –
2,394,120 sqft
1. 4200 Smoke Detectors
2. 34 Heat Detectors
3. 60 Duct Detectors
4. 158 Manual Pull Stations
5. 908 Strobes
6. 197 Speakers
7. 75 Fire Phones
8. 2 Novec Gaseous Suppression System (B314A, 2403)
a. 22 Smoke Detectors
b. 1 Manual Fire Alarm Stations
c. 2 Horns
d. 4 Strobes
e. 2 Horn/Strobes
f. 1 Actuation Solenoid
9. 4 Wet Chemical Suppression Systems
10. 2 Fire Pumps
11. 6 Dry Sprinkler Systems
12. 126 Standpipe Outlets
13. 2 VESDA Air Sampling Smoke Detection Systems
14. Wet Pipe Sprinklers Throughout Building
.4 Ford House Office Building – Autocall AL1500 Multiplex fire alarm system – 594,733 sqft
1. 1800 Smoke Detectors
2. 22 Heat Detectors
3. 20 Duct Detectors
4. 94 Manual Pull Stations
5. 191 Strobes
6. 3138 Speakers
7. 85 Fire Phones
8. 3 Novec Gaseous Suppression Systems (H2-B05, H2-211, 6th Fl. Data Center)
a. 333 Smoke Detectors
b. 9 Manual Fire Alarm Stations
c. 12 Horns
d. 18 Strobes
e. 14 Horn/Strobes
f. 9 Actuation Solenoids
8. 2 Wet Chemical Suppression Systems
9. 2 Fire Pumps
10. 1 Dry Pipe Sprinkler System
11. 80 Standpipe Outlets
12. Wet Pipe Sprinklers Throughout Building
13. 1 Notifier Onyx Workstation
.5 East and West House Office Building Garages (Underground Shops/Parking Area) –
Notifier NFS 640 addressable fire alarm systems – 577,350 sqft
1. 78 Smoke Detectors
2. 12 Heat Detectors
3. 20 Duct Detectors
4. 35 Manual Fire Alarm Stations
5. 10 Speakers
6. 282 Speaker/Strobes
7. 7 Dry Pipe Sprinkler Systems (1 in East, 6 in West)
8. 23 Standpipe Outlets
9. 1 Dry Chemical Suppression System
10. Wet Pipe Sprinklers Throughout Building
.6 O’Neill House Office Building – Simplex 4100U addressable voice fire alarm system –
548,345 sqft
1. See Fire Alarm Points list for type/number of devices for additional information
2. See Fire Alarm As-Built Drawings for additional information
3. Wet Pipe sprinklers throughout the building
4. 1 Dry Pipe System
5. 1 Fire Pump
6. Standpipe System
7. Stair Pressurization System (4 stairs)
File details come from the government source that posted it. Updated .