Amendment 0003 Page 220-239 1665143 DWG.pdf

PDF 12 MB Posted

Attached to
B115 Life Extension Center- Lean-to Construction
Solicitation number
Not on record
Issued by

About this file

This document is Amendment 0003 to Solicitation No. N40080-18-R-0002 X025 for the B115 Life Extension Center- Lean-to Construction project. The solicitation is reserved exclusively for vendors on the Blue Small Business MACC (Multiple Award Construction Contract) managed by NAVFAC Washington.

The amendment includes the following attachments: RFI responses, a Hazmat report, a 20-year warranty letter, revised drawings, and a revised solicitation. The revised solicitation deletes CLIN 0002, updates the price schedule, and revises the wage determination. The proposal due date is Monday, July 22, 2024 by 2:00 pm local time. The project involves lean-to construction at the B115 Life Extension Center. The work is to be performed for the Department of the Navy, Naval Facilities Engineering Command.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Ammendment #3

• E-621 – updated panel schedules

• E-622 – updated panel schedules

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G S Y S

TE

M S C O M M A N D W A S H

IN

G T O N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N

D C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

E-621

F Y H A E H A N G A R L

IF

E E X T E N S

IO

N

P A N E

LB

O A R D S C H E D U

LE

S

TEH

SCM SCM

M A

R Y

LA

N

D N

A S

P A

T U

X E

N T

R

IV

E R

13149205

1. REFER TO SHEETS E-001 & E-002 FOR ELECTRICAL

GENERAL NOTES, ABBREVIATIONS & LEGEND.

GENERAL SHEET NOTES

Aircraft Plug 647.12 kVA 121.34 kVA

Inverter 618.56 kVA 309.28 kVA

RECP - GENERAL USE 0.72 kVA 0.72 kVA

Recp - General Purpose 93.60 kVA 51.80 kVA

Recp - Specific Appliance or Load 58.22 kVA 58.22 kVA

Spare 38.98 kVA 38.98 kVA

Power 170.58 kVA 170.58 kVA TOTAL EST. DESIGN CURRENT:

Other 5.08 kVA 5.08 kVA TOTAL EST. DEMAND CURRENT: 1168 A

Lighting 0.17 kVA 0.17 kVA TOTAL CONN. CURRENT: 2223 A

LTG 6.12 kVA 6.12 kVA TOTAL EST. DEMAND LOAD: 971.22 kVA

HVAC 209.09 kVA 209.09 kVA TOTAL CONN. LOAD: 1848.09 kVA

LOAD CLASSIFICATION: CONNECTED LOAD ESTIMATED DEMAND PANEL TOTALS

NOTES:

10 SPACE 1 -- --

9 SPACE 1 -- --

8 SPARE 1 20 A 0.0 kVA

7 N-HGR-SM-W (EXISTING PANEL) 3 400 A 64.0 kVA 4-500 KCMIL & 1#2G, 4"C.

6 N-HGR-SM-E (EXISTING PANEL) 3 400 A 64.0 kVA 4-500 KCMIL & 1#2G, 4"C.

5 NP41B 3 400 A 647.1 kVA

4 NP41A 3 800 A 618.6 kVA

3 T-NP21A 3 350 A 222.9 kVA

2 NM41A 3 800 A 225.4 kVA

1 NL41A 3 100 A 6.3 kVA

CKT CIRCUIT DESCRIPTION POLES

TRIP

RATING LOAD COMMENTS

SCCR RATING: 65,000 A

WIRES: 4

ENCLOSURE: NEMA 1 PHASES: 3

MOUNTING: FLOOR VOLTAGE: 480Y/277

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 1200A MCB

SWITCHBOARD: NMDP

TOTAL EST. DESIGN CURRENT:

TOTAL EST. DEMAND CURRENT: 372 A

TOTAL CONN. CURRENT: 744 A

TOTAL EST. DEMAND LOAD: 309.28 kVA

Inverter 618.56 kVA 309.28 kVA TOTAL CONN. LOAD: 618.56 kVA

LOAD CLASSIFICATION: CONNECTED LOAD ESTIMATED DEMAND PANEL TOTALS

NOTES: DEMAND CURRENT IS CALCULATED WITH A MAX OF FOUR 400HZ FREQUENCY CONVERTERS BEING

UTILIZED AT ONE TIME.

10 SPARE 3 100 A 0.0 kVA

9 SPARE 3 100 A 0.0 kVA

8 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

7 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

6 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

5 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

4 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

3 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

2 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

1 PWR - 400 HZ FREQUENCY CONVERTER 3 150 A 77.3 kVA

CKT CIRCUIT DESCRIPTION POLES

TRIP

RATING LOAD COMMENTS

SCCR RATING: 22,000 A

WIRES: 4

ENCLOSURE: NEMA 1 PHASES: 3

MOUNTING: SURFACE VOLTAGE: 480Y/277

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 800A MCB

DISTRIBUTION PANEL: NP41A

NOTES:

EST. DEMAND CURRENT: 9 A

TOTAL LOAD: 2.70 1.80 1.83 CONNECTED CURRENT: 8 A

29 -- SPACE -- 1 -- -- 1 -- SPACE -- 30

27 -- SPACE -- 1 -- -- 1 -- SPACE -- 28

25 -- SPACE -- 1 -- -- 1 -- SPACE -- 26

23 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 24

21 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 22

19 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 20

17 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 18

15 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 16

13 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 14

11 2#12 & 1#12G, 3/4"C. LTG C114 20 A 1 0.10 0.52 1 20 A LTG C114A, C115, C116 2#12 & 1#12G, 3/4"C. 12

9 2#12 & 1#12G, 3/4"C. LTG C111, C111A, C112 20 A 1 0.23 0.57 1 20 A LTG C113 2#12 & 1#12G, 3/4"C. 10

7 2#12 & 1#12G, 3/4"C. LTG C105, C106, C106A, C107,... 20 A 1 1.11 0.19 1 20 A LTG C108, C109, C110 2#12 & 1#12G, 3/4"C. 8

5 -- -- -- -- 0.82 0.40 1 20 A LTG C104, C104A, C104B 2#12 & 1#12G, 3/4"C. 6

3 -- -- -- -- 0.79 0.22 1 20 A LTG C102, C103 2#12 & 1#12G, 3/4"C. 4

1 REFER TO E-602 NL42A 50 A 3 1.30 0.10 1 20 A LTG C201 2#12 & 1#12G, 3/4"C. 2

CKT WIRE SIZE CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION WIRE SIZE CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: NMDP VOLTAGE: 480Y/277

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 100A MCB MINIMUM BREAKER SCCR: 18,000 A

PANELBOARD SCHEDULE NL41A

NOTES:

EST. DEMAND CURRENT: 4 A

TOTAL LOAD: 1.30 0.79 0.82 CONNECTED CURRENT: 4 A

29 -- SPACE -- 1 -- -- 1 -- SPACE -- 30

27 -- SPACE -- 1 -- -- 1 -- SPACE -- 28

25 -- SPACE -- 1 -- -- 1 -- SPACE -- 26

23 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 24

21 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 22

19 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 20

17 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 18

15 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 16

13 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 14

11 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 12

9 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 10

7 2#12 & 1#12G, 3/4"C. LTG C211, C212, C213 20 A 1 0.24 0.00 1 20 A SPARE -- 8

5 2#12 & 1#12G, 3/4"C. LTG C205, C206, C206A, C206B 20 A 1 0.54 0.28 1 20 A LTG C207, C208, C214 2#12 & 1#12G, 3/4"C. 6

3 2#12 & 1#12G, 3/4"C. LTG C203, C203A - C203D 20 A 1 0.44 0.35 1 20 A LTG C204, C204A - C204D 2#12 & 1#12G, 3/4"C. 4

1 2#12 & 1#12G, 3/4"C. LTG C202.1 20 A 1 0.46 0.60 1 20 A LTG C202, C202A, C202B 2#12 & 1#12G, 3/4"C. 2

CKT WIRE SIZE CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION WIRE SIZE CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: NL41A VOLTAGE: 480Y/277

LOCATION: ELECTRICAL CLOSET C209 MAINS RATING: 50A MCB MINIMUM BREAKER SCCR: 10,000 A

PANELBOARD SCHEDULE NL42A

TOTAL EST. DESIGN CURRENT:

Recp - General Purpose 0.36 kVA 0.36 kVA TOTAL EST. DEMAND CURRENT: 271 A

Power 19.72 kVA 19.72 kVA TOTAL CONN. CURRENT: 271 A

Other 3.00 kVA 3.00 kVA TOTAL EST. DEMAND LOAD: 225.36 kVA

HVAC 202.28 kVA 202.28 kVA TOTAL CONN. LOAD: 225.36 kVA

LOAD CLASSIFICATION: CONNECTED LOAD ESTIMATED DEMAND PANEL TOTALS

NOTES:

20 SPACE 1 -- --

19 SPACE 1 -- --

18 SPACE 1 -- --

17 SPACE 1 -- --

16 SPACE 1 -- --

15 SPARE 3 100 A 0.0 kVA

14 SPARE 3 100 A 0.0 kVA

13 SPARE 3 100 A 0.0 kVA

12 SPARE 3 100 A 0.0 kVA

11 SPARE 3 100 A 0.0 kVA

10 AC-1 3 45 A 28.3 kVA

9 EWH-1 3 20 A 12.0 kVA

8 EWH-2 1 20 A 6.0 kVA

7 P-01 3 20 A 4.9 kVA

6 P-02 3 20 A 4.9 kVA

5 RTU-2C-01 3 125 A 74.5 kVA

4 RTU-1C-01 3 100 A 55.2 kVA

3 RTU-1C-02 3 25 A 12.0 kVA

2 T-NM22A 3 125 A 10.0 kVA

1 T-NM21A 3 125 A 17.7 kVA

CKT CIRCUIT DESCRIPTION POLES

TRIP

RATING LOAD COMMENTS

SCCR RATING: 22,000 A

WIRES: 4

ENCLOSURE: NEMA 1 PHASES: 3

MOUNTING: SURFACE VOLTAGE: 480Y/277

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 800A MLO

DISTRIBUTION PANEL: NM41A

NOTES:

EST. DEMAND CURRENT: 57 A

TOTAL LOAD: 8.20 3.24 6.31 CONNECTED CURRENT: 49 A

41 -- SPACE -- 1 -- -- 1 -- SPACE -- 42

39 -- SPACE -- 1 -- -- 1 -- SPACE -- 40

37 -- SPACE -- 1 -- -- 1 -- SPACE -- 38

35 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 36

33 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 34

31 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 32

29 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 30

27 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 28

25 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 26

23 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 24

21 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 22

19 REFER TO E-612 SP-1 20 A 1 1.18 0.00 1 20 A SPARE -- 20

17 REFER TO E-612 B-01 30 A 1 2.40 0.50 1 20 A POWER - HVAC CNTRL PNL - C102 2#12 & 1#12G, 3/4"C. 18

15 2#12 & 1#12G, 3/4"C. SSHP-1C-01 COND PUMP 20 A 1 0.08 0.16 1 20 A HUH-1C- 02, CUH-1C-01 REFER TO E-612 16

13 2#12 & 1#12G, 3/4"C. MODS 20 A 1 1.00 2.40 1 30 A B-02 REFER TO E-612 14

11 2#12 & 1#12G, 3/4"C. MODS 20 A 1 0.50 1.50 1 20 A VAV-1C-(01, 02, 03) REFER TO E-612 12

9 2#12 & 1#12G, 3/4"C. MODS 20 A 1 0.50 0.50 1 20 A MODS 2#12 & 1#12G, 3/4"C. 10

7 -- -- -- -- 0.91 1.00 1 20 A VAV-1C-(04, 05) REFER TO E-612 8

5 REFER TO E-612 EF-1C-(02, 03, 04) 20 A 2 0.91 0.50 1 20 A MODS REFER TO E-612 6

3 -- -- -- -- 1.00 1.00 1 20 A VAV-1C-(06, 07) REFER TO E-612 4

1 REFER TO E-612 SCCU-1C-01/SSHP-1C-01 25 A 2 1.00 0.71 1 20 A CUH-1C-02, VAV-1C-08 REFER TO E-612 2

CKT WIRE SIZE CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION WIRE SIZE CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: T-NM21A VOLTAGE: 208Y/120

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 250A MCB MINIMUM BREAKER SCCR: 10,000 A

PANELBOARD SCHEDULE NM21A

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

A

M E

N D

M E

N T

/0

8/

AMENDMENT #1 - 08 JUL 2024

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G S Y S

TE

M S C O M M A N D W A S H

IN

G T O N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N

D C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

E-622

F Y H A E H A N G A R L

IF

E E X T E N S

IO

N

P A N E

LB

O A R D S C H E D U

LE

S

TEH

SCM SCM

M A

R Y

LA

N

D N

A S

P A

T U

X E

N T

R

IV

E R

13149206

1. REFER TO SHEETS E-001 & E-002 FOR ELECTRICAL

GENERAL NOTES, ABBREVIATIONS & LEGEND.

GENERAL SHEET NOTES

NOTES:

EST. DEMAND CURRENT: 32 A

TOTAL LOAD: 3.34 5.02 1.63 CONNECTED CURRENT: 28 A

41 -- SPACE -- 1 -- -- 1 -- SPACE -- 42

39 -- SPACE -- 1 -- -- 1 -- SPACE -- 40

37 -- SPACE -- 1 -- -- 1 -- SPACE -- 38

35 -- SPACE -- 1 -- -- 1 -- SPACE -- 36

33 -- SPACE -- 1 -- -- 1 -- SPACE -- 34

31 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 32

29 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 30

27 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 28

25 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 26

23 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 24

21 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 22

19 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 20

17 REFER TO E-612 RP-2 20 A 1 0.12 0.05 1 20 A BF-01 REFER TO E-612 18

15 -- -- -- -- 0.96 0.12 1 20 A RP-1 REFER TO E-612 16

13 REFER TO E-612 EF-2C-02 20 A 2 0.96 0.18 1 20 A Recp - CONVIENCE 2#12 & 1#12G, 3/4"C. 14

11 REFER TO E-612 AD-1 20 A 1 0.21 0.18 1 20 A Recp - CONVIENCE 2#12 & 1#12G, 3/4"C. 12

9 REFER TO E-612 VAV-2C-(03, 05) 20 A 1 1.00 1.50 1 20 A VAV-2C-(01, 02, 04) REFER TO E-612 10

7 REFER TO E-612 VAV-2C-(06, 07) 20 A 1 1.00 0.07 -- -- -- -- 8

5 REFER TO E-612 VAV-2C-(08, 09), EF-2C-02 20 A 1 1.00 0.07 2 20 A EF-1C-01 REFER TO E-612 6

3 REFER TO E-612 VAV-2C-(10, 11), HUH-2C-01 20 A 1 1.03 0.42 -- -- -- -- 4

1 2#12 & 1#12G, 3/4"C. MOD 20 A 1 0.72 0.42 2 20 A EF-2C-01 REFER TO E-612 2

CKT WIRE SIZE CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION WIRE SIZE CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: T-NM22A VOLTAGE: 208Y/120

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 250A MCB MINIMUM BREAKER SCCR: 10,000 A

PANELBOARD SCHEDULE NM22A

RECP - GENERAL USE 0.72 kVA 0.72 kVA

Recp - General Purpose 93.24 kVA 51.62 kVA

Recp - Specific Appliance or Load 58.22 kVA 58.22 kVA TOTAL EST. DESIGN CURRENT:

Spare 38.98 kVA 38.98 kVA TOTAL EST. DEMAND CURRENT: 503 A

Power 22.94 kVA 22.94 kVA TOTAL CONN. CURRENT: 619 A

Other 2.02 kVA 2.02 kVA TOTAL EST. DEMAND LOAD: 181.32 kVA

HVAC 6.81 kVA 6.81 kVA TOTAL CONN. LOAD: 222.94 kVA

LOAD CLASSIFICATION: CONNECTED LOAD ESTIMATED DEMAND PANEL TOTALS

NOTES:

14 SPACE 1 -- --

13 SPARE 3 100 A 0.0 kVA

12 SPARE 3 100 A 0.0 kVA

11 SPARE 3 100 A 0.0 kVA

10 EXISTING PANEL 18 (SUB FEEDS TO 16 & 17) 3 175 A 14.1 kVA 4#3/0 & 1#4G, 2"C.

9 EXISTING PANEL 9 (SUB FEEDS TO 7 & 8) 3 175 A 11.4 kVA 4#2/0 & 1#6G, 2"C.

8 EXISTING PANEL 15 (SUB FEEDS TO 13 & 14) 3 175 A 6.6 kVA 4#2/0 & 1#6G, 2"C.

7 EXISTING PANEL 12 (SUB FEEDS TO 10 & 11) 3 175 A 6.9 kVA 4#3/0 & 1#4G, 2"C.

6 GFGI 28V INVERTER 3 60 A 0.0 kVA

5 NC22A 3 100 A 33.5 kVA

4 NP22B 3 200 A 28.6 kVA

3 NP22A 3 200 A 37.6 kVA

2 NP21C 3 200 A 40.0 kVA

1 NP21B 3 125 A 44.3 kVA

CKT CIRCUIT DESCRIPTION POLES

TRIP

RATING LOAD COMMENTS

SCCR RATING: 14,000 A

WIRES: 4

ENCLOSURE: NEMA 1 PHASES: 3

MOUNTING: SURFACE VOLTAGE: 208Y/120

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 800A MCB

DISTRIBUTION PANEL: NP21A

NOTES: * PROVIDE HANDLE TIE FOR SYSTEMS FURNITURE

EST. DEMAND CURRENT: 141 A

TOTAL LOAD: 15.62 13.58 15.05 CONNECTED CURRENT: 123 A

53 -- SPACE -- 1 -- -- 1 -- SPACE -- 54

51 -- SPACE -- 1 -- -- 1 -- SPACE -- 52

49 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 50

47 2#12 & 1#12G, 3/4"C. NAC PANEL - C103 20 A 1 0.50 0.18 1 20 A Recp - CAMERA MONITOR C109 2#12 & 1#12G, 3/4"C. 48

45 2#12 & 1#12G, 3/4"C. DACT PANEL - C103 20 A 1 0.50 0.18 1 20 A Recp - DVR C109 2#12 & 1#12G, 3/4"C. 46

43 2#12 & 1#12G, 3/4"C. SYS FURN RM C104 20 A 1 0.54 0.54 1 20 A SYS FURN RM C107 2#12 & 1#12G, 3/4"C. 44

41 2#12 & 1#12G, 3/4"C. SYS FURN RM C104 20 A 1 0.54 0.54 1 20 A SYS FURN RM C107 2#12 & 1#12G, 3/4"C. 42

39 2#12 & 1#12G, 3/4"C. SYS FURN RM C104 20 A 1 0.54 0.54 1 20 A SYS FURN RM C107 2#12 & 1#12G, 3/4"C. 40

37 2#12 & 1#12G, 3/4"C. SYS FURN RM C104 20 A 1 0.54 0.54 1 20 A SYS FURN RM C107 2#12 & 1#12G, 3/4"C. 38

35 2#12 & 1#12G, 3/4"C. RECP - C106, C107 20 A 1 1.08 1.20 1 20 A RECP - PRINTER - C105 2#12 & 1#12G, 3/4"C. 36

33 2#12 & 1#12G, 3/4"C. RECP - C106 20 A 1 0.90 1.08 1 20 A RECP - C105 2#12 & 1#12G, 3/4"C. 34

31 2#12 & 1#12G, 3/4"C. RECP - C104 20 A 1 1.08 1.08 1 20 A RECP - C105, C106 2#12 & 1#12G, 3/4"C. 32

29 2#12 & 1#12G, 3/4"C. RECP - C106 20 A 1 0.90 0.90 1 20 A RECP - C105 2#12 & 1#12G, 3/4"C. 30

27 2#12 & 1#12G, 3/4"C. RECP - C105 20 A 1 0.90 0.90 1 20 A RECP - C105 2#12 & 1#12G, 3/4"C. 28

25 2#12 & 1#12G, 3/4"C. RECP - C102 20 A 1 0.90 1.08 1 20 A RECP - C106 2#12 & 1#12G, 3/4"C. 26

23 2#12 & 1#12G, 3/4"C. RECP - C107 20 A 1 0.90 0.90 1 20 A RECP - C106 2#12 & 1#12G, 3/4"C. 24

21 2#12 & 1#12G, 3/4"C. RECP - C106A 20 A 1 0.90 0.90 1 20 A RECP - C106 2#12 & 1#12G, 3/4"C. 22

19 2#12 & 1#12G, 3/4"C. RECP - C106 20 A 1 0.90 0.90 1 20 A RECP - C105 2#12 & 1#12G, 3/4"C. 20

17 -- -- -- -- 2.88 0.72 1 20 A RECP - FLOOR - C104 2#12 & 1#12G, 3/4"C. 18

15 -- -- -- -- 2.88 0.72 1 20 A RECP - C107A 2#12 & 1#12G, 3/4"C. 16

13 3#12 & 1#12G, 3/4"C. RECP - DRYER C104B 20 A 3 2.88 0.90 1 20 A RECP - C106A 2#12 & 1#12G, 3/4"C. 14

11 2#12 & 1#12G, 3/4"C. RECP - MICROWAVE - C104 20 A 1 1.10 1.20 1 20 A RECP - COFFEE MACHINE - C104 2#12 & 1#12G, 3/4"C. 12

9 2#12 & 1#12G, 3/4"C. RECP - C105 20 A 1 0.54 0.72 1 20 A RECP - C107 2#12 & 1#12G, 3/4"C. 10

7 2#12 & 1#12G, 3/4"C. RECP - C104 20 A 1 1.92 0.72 1 20 A RECP - C103 2#12 & 1#12G, 3/4"C. 8

5 2#12 & 1#12G, 3/4"C. FMCU - C103 20 A 1 0.50 1.01 1 20 A RECP - CEILING TV - C106 2#12 & 1#12G, 3/4"C. 6

3 2#12 & 1#12G, 3/4"C. RECP - WASHER - C104B 20 A 1 0.84 0.54 1 20 A RECP - C104, C104A , C104B 2#12 & 1#12G, 3/4"C. 4

1 2#12 & 1#12G, 3/4"C. RECP - REFRIGERATOR - C104 20 A 1 0.09 1.01 1 20 A RECP - CEILING TV - C105 2#12 & 1#12G, 3/4"C. 2

CKT WIRE SIZE CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION WIRE SIZE CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: NP21A VOLTAGE: 208Y/120

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 400A MCB MINIMUM BREAKER SCCR: 10,000 A

PANELBOARD SCHEDULE NP21B

NOTES: * PROVIDE HANDLE TIE FOR SYSTEMS FURNITURE

EST. DEMAND CURRENT: 128 A

TOTAL LOAD: 14.21 14.06 11.78 CONNECTED CURRENT: 111 A

53 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 54

51 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 52

49 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 50

47 2#12 & 1#12G, 3/4"C. RECP - PRINTER C110 20 A 1 1.20 0.00 1 20 A SPARE -- 48

45 2#12 & 1#12G, 3/4"C. RECP - C110 20 A 1 1.08 0.00 1 20 A SPARE -- 46

43 2#12 & 1#12G, 3/4"C. RECP - C110 20 A 1 0.90 0.18 1 20 A RECP - ACCESS CONTROL... 2#12 & 1#12G, 3/4"C. 44

41 2#12 & 1#12G, 3/4"C. RECP - REFRIGERATOR - C107 20 A 1 0.09 1.08 1 20 A RECP - C109 2#12 & 1#12G, 3/4"C. 42

39 2#12 & 1#12G, 3/4"C. RECP - PRINTER - C107 20 A 1 1.20 1.10 1 20 A RECP - MICROWAVE - C107 2#12 & 1#12G, 3/4"C. 40

37 2#12 & 1#12G, 3/4"C. SYS FURN RM C106 20 A 1 1.26 1.20 1 20 A RECP - COFFEE MACHINE - C107 2#12 & 1#12G, 3/4"C. 38

35 2#12 & 1#12G, 3/4"C. SYS FURN RM C106 20 A 1 1.26 0.54 1 20 A SYS FURN RM C105 2#12 & 1#12G, 3/4"C. 36

33 2#12 & 1#12G, 3/4"C. SYS FURN RM C106 20 A 1 1.26 0.54 1 20 A SYS FURN RM C105 2#12 & 1#12G, 3/4"C. 34

31 2#12 & 1#12G, 3/4"C. SYS FURN RM C106 20 A 1 1.26 0.54 1 20 A SYS FURN RM C105 2#12 & 1#12G, 3/4"C. 32

29 2#12 & 1#12G, 3/4"C. SYS FURN RM C113 20 A 1 0.72 0.54 1 20 A SYS FURN RM C105 2#12 & 1#12G, 3/4"C. 30

27 2#12 & 1#12G, 3/4"C. SYS FURN RM C113 20 A 1 0.72 0.72 1 20 A SYS FURN RM C113 2#12 & 1#12G, 3/4"C. 28

25 2#12 & 1#12G, 3/4"C. SYS FURN RM C113 20 A 1 0.72 0.72 1 20 A SYS FURN RM C113 2#12 & 1#12G, 3/4"C. 26

23 2#12 & 1#12G, 3/4"C. SYS FURN RM C113 20 A 1 0.72 0.72 1 20 A SYS FURN RM C113 2#12 & 1#12G, 3/4"C. 24

21 2#12 & 1#12G, 3/4"C. RECP - PRINTER - C116 20 A 1 1.20 0.72 1 20 A SYS FURN RM C113 2#12 & 1#12G, 3/4"C. 22

19 2#12 & 1#12G, 3/4"C. RECP - REFRIGERATOR - C116 20 A 1 0.09 1.20 1 20 A RECP - COFFEE MACHINE - C116 2#12 & 1#12G, 3/4"C. 20

17 2#12 & 1#12G, 3/4"C. RECP - C116 20 A 1 0.90 1.10 1 20 A RECP - MICROWAVE - C116 2#12 & 1#12G, 3/4"C. 18

15 2#12 & 1#12G, 3/4"C. RECP - C116 20 A 1 1.08 0.72 1 20 A RECP - C116 2#12 & 1#12G, 3/4"C. 16

13 2#12 & 1#12G, 3/4"C. RECP - MICROWAVE - C113 20 A 1 1.10 1.26 1 20 A RECP - C114, C114A, C115 2#12 & 1#12G, 3/4"C. 14

11 2#12 & 1#12G, 3/4"C. RECP - REFRIGERATOR - C113 20 A 1 0.09 1.20 1 20 A RECP - COFFEE MACHINE - C113 2#12 & 1#12G, 3/4"C. 12

9 2#12 & 1#12G, 3/4"C. RECP - C113 20 A 1 0.90 0.72 1 20 A RECP - C113 2#12 & 1#12G, 3/4"C. 10

7 2#12 & 1#12G, 3/4"C. RECP - C113 20 A 1 0.72 0.90 1 20 A RECP - C113 2#12 & 1#12G, 3/4"C. 8

5 2#12 & 1#12G, 3/4"C. RECP - C113 20 A 1 0.72 0.90 1 20 A RECP - C113 2#12 & 1#12G, 3/4"C. 6

3 2#12 & 1#12G, 3/4"C. RECP - PRINTER - C113 20 A 1 1.20 0.90 1 20 A RECP - C113 2#12 & 1#12G, 3/4"C. 4

1 2#12 & 1#12G, 3/4"C. RECP - C111 20 A 1 0.90 1.26 1 20 A RECP - RM C113 2#12 & 1#12G, 3/4"C. 2

CKT WIRE SIZE CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION WIRE SIZE CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: NP21A VOLTAGE: 208Y/120

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 200A MCB MINIMUM BREAKER SCCR: 14,000 A

PANELBOARD SCHEDULE NP21C

NOTES: DEMAND CURRENT IS CALCULATED WITH A MAX OF THREE CONVERTER PLUGS BEING UTILIZED AT ONE TIME.

EST. DEMAND CURRENT: 146 A

TOTAL LOAD: 215.71 215.71 215.71 CONNECTED CURRENT: 778 A

53 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 54

51 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 52

49 -- SPARE 20 A 1 0.00 0.00 1 20 A SPARE -- 50

47 -- -- -- -- 10.06 10.06 -- -- -- -- 48

45 -- -- -- -- 10.06 10.06 -- -- -- -- 46

43 3#4 & 1#10G, 1-1/4"C. EXISTING CONVERTER 60 A 3 10.06 10.06 3 60 A EXISTING CONVERTER 3#4 & 1#10G, 1-1/4"C. 44

41 -- -- -- -- 10.06 10.06 -- -- -- -- 42

39 -- -- -- -- 10.06 10.06 -- -- -- -- 40

37 3#4 & 1#10G, 1-1/4"C. EXISTING CONVERTER 60 A 3 10.06 10.06 3 60 A EXISTING CONVERTER 3#4 & 1#10G, 1-1/4"C. 38

35 -- -- -- -- 10.06 10.06 -- -- -- -- 36

33 -- -- -- -- 10.06 10.06 -- -- -- -- 34

31 3#4 & 1#10G, 1-1/4"C. EXISTING CONVERTER 60 A 3 10.06 10.06 3 60 A EXISTING CONVERTER 3#4 & 1#10G, 1-1/4"C. 32

29 -- -- -- -- 10.06 10.06 -- -- -- -- 30

27 -- -- -- -- 10.06 10.06 -- -- -- -- 28

25 3#4 & 1#10G, 1-1/4"C. EXISTING CONVERTER 60 A 3 10.06 10.06 3 60 A EXISTING CONVERTER 3#4 & 1#10G, 1-1/4"C. 26

23 -- -- -- -- 16.90 16.90 -- -- -- -- 24

21 -- -- -- -- 16.90 16.90 -- -- -- -- 22

19 3#1 & 1#8G, 2"C. EXISTING CONVERTER 100 A 3 16.90 16.90 3 100 A EXISTING CONVERTER 3#1 & 1#8G, 2"C. 20

17 -- -- -- -- 16.90 16.90 -- -- -- -- 18

15 -- -- -- -- 16.90 16.90 -- -- -- -- 16

13 3#1 & 1#8G, 2"C. EXISTING CONVERTER 100 A 3 16.90 16.90 3 100 A EXISTING CONVERTER 3#1 & 1#8G, 2"C. 14

11 -- -- -- -- 16.90 16.90 -- -- -- -- 12

9 -- -- -- -- 16.90 16.90 -- -- -- -- 10

7 3#1 & 1#8G, 2"C. EXISTING CONVERTER 100 A 3 16.90 16.90 3 100 A EXISTING CONVERTER 3#1 & 1#8G, 2"C. 8

5 -- -- -- -- 16.90 16.90 -- -- -- -- 6

3 -- -- -- -- 16.90 16.90 -- -- -- -- 4

1 3#1 & 1#8G, 2"C. EXISTING CONVERTER 100 A 3 16.90 16.90 3 100 A EXISTING CONVERTER 3#1 & 1#8G, 2"C. 2

CKT WIRE SIZE CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION WIRE SIZE CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: NMDP VOLTAGE: 480Y/277

LOCATION: ELECTRICAL ROOM C111 MAINS RATING: 400A MCB MINIMUM BREAKER SCCR: 22,000

PANELBOARD SCHEDULE NP41B

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

A

M E

N D

M E

N T

/0

8/

AMENDMENT #1 - 08 JUL 2024

G-001 - COVER SHEET
G-002 - DRAWING INDEX
GS001 - MAINTENANCE CONTROL FLOOR PLANS AND SPECIFICATIONS
GS002 - MAINTENANCE CONTROL FURNITURE PLAN & DETAILS
CD101 - EXISTING CONDITIONS AND DEMOLITION PLAN
A-001 - ARCHITECTURAL GENERAL NOTES, MATERIAL AND ANNOTATION
AD121 - DEMOLITION PLANS -SECOND FLOOR -AREAS A AND B
A-211 - INTERIOR ELEVATIONS -HANGAR WALLS AREAS A & B
AD403 - ENLARGED ELEVATOR DEMOLITION PLANS AND SECTIONS
A-121 - SECOND FLOOR PLAN -AREAS A AND B
A-211 - INTERIOR ELEVATIONS -HANGAR WALLS AREAS A & B
A-403 - ENLARGED PLANS AND SECTIONS -ELEVATOR
A-501 - DETAILS
A-521 - WINDOW DETAILS
A-601 - PARTITION TYPES
A-611 - DOOR TYPES AND SCHEDULE
A-621 - WINDOW TYPES
E-621 - PANELBOARD SCHEDULES
E-622 - PANELBOARD SCHEDULES
2024-07-10T12:09:16-0400
GUTH.CRAIG.SUTTER.1019479966
2024-07-10T12:09:41-0400
GUTH.CRAIG.SUTTER.1019479966

File details come from the government source that posted it. Updated .