07900_-_joint_sealers.docx
DOCX document 17 KB Posted
- Solicitation number
- AG-83A7-S-10-0020
About this file
Attachment - Specifications
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF 30.pdf | ||
| resp pkg 20 TP warehouse roof.docx | DOCX document | |
| A-1 Model | — | |
| A-5 Model | — | |
| T-1_TITLESHT T1.pdf | ||
| 01330-submittal_procedure.rtf | RTF text file | |
| A-4 Model | — | |
| 13100_Lightning_Protection_BSD.rtf | RTF text file | |
| 01300-mobilization.rtf | RTF text file | |
| 20 TP warehouse roof.docx | DOCX document | |
| A-3 Model | — | |
| 01732_02.doc | DOC document | |
| A-6 Model | — | |
| 07130_-_underlaymentr.rtf | RTF text file | |
| A-2 Model | — | |
| Wage Det NM100001 6-4-10 NM1.docx | DOCX document | |
| 07410-metal_roofing.rtf | RTF text file |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 07900
JOINT SEALERS
PART 1 - GENERAL
SUMMARY
Provide sealants at intersection of exterior building components such as new windows and doors. Also, seal around all new work occurring in the interior of the residence such as sinks, bathroom toilet/tub and wall and floor tile.
SUBMITTALS
Submit for approval samples, product data.
Exterior caulking.
Interior sealants.
The required applications of sealants and caulking include (but are not necessarily limited to) the following:
Skylights.
Flashing.
Around perimeter of all exterior doors, windows, grilles, and other openings.
Slab expansion joints.
Isolation joints, between structure and other elements.
Joints at penetrations of walls, decks and floors by piping and other services and equipment.
Joints between items of equipment and other construction.
All locations where some movement can be expected.
Between dissimilar materials.
QUALITY ASSURANCE
Comply with governing codes and regulations. Provide products of acceptable manufacturers which have been in satisfactory use in similar service for three years. Use experienced installers. Deliver, handle, and store materials in accordance with manufacturer's instructions.
PART 2 - PRODUCTS
MATERIALS
Joints designed for expansion and movement.
Miscellaneous Exterior Joints: Two component gun-grade polyurethane; Sonneborn Sonolastic NP2 or Mameco Vulken 922, or equal.
Interior Slab Joints: One component self-leveling non-priming polyurethane; Sonneborn Sonolastic SL1 or Mameco Vulken 45, or equal.
Miscellaneous Interior Joints including Plumbing Fixtures: One-part non-sag paintable silicone sealant; Sonneborn Sonolastic OmniPlus or Pecora 863 Silicone, or equal.
Precompressed expanding sealant tape; Emseal PC-SA or approved equal.
Pavement Joint Filler: Resilient, premolded asphalt impregnated fiberboard.
Primers, bond breakers, and backer rods compatible with sealant and adjacent surfaces by Sealant manufacturer.
Compatability: Before purchase of each specified sealant, investigate its compatibility with the joint surfaces, joint fillers and other materials in the joint system. Provide only materials (manufacturer's recommended variation of the specified materials) which are known to be fully compatible with the actual installation condition, as shown by manufacturer's published data or certification.
PART 3 - EXECUTION
INSTALLATION
Examine substrate; report unsatisfactory conditions in writing. Beginning work means acceptance of substrates.
Provide sealants in colors as selected from manufacturer's standards to match adjacent building material color as approved by COR.
Install materials and systems in accordance with manufacturer's instructions and approved submittals. Install materials and systems in proper relation with adjacent construction and with uniform appearance. Coordinate with work of the sections. Clean and prime joints, and install bond breakers, backer roads and sealant as recommended by manufacturers.
Depth shall equal width up to 1/2" wide; depth shall equal 1/2 width for joints over 1/2"wide for joints; except for concrete expansion joints, which shall be the depth of the joint and not exceed 1/2" wide.
Cure and protect sealants as directed by manufacturers. Replace or restore damaged sealants. Clean adjacent surfaces to remove spillage.
PART 4 - MEASUREMENT AND PAYMENT
MEASUREMENT
The work specified herein will not be measured for payment.
PAYMENT
This work is incidental to other items in this contract and direct separate item payments will not be made.
END OF SECTION
07900 - 2 07900 - 1
File details come from the government source that posted it. Updated .