About this file

Lithonia WAL-14

View the file

Other files

File Type Posted
Abstract of Bids S-09-0019.pdf PDF
Amendment 2.pdf PDF
NSSL 0231.TIF TIF image
NSSL 0229.TIF TIF image
NSSL 0233.TIF TIF image
2002 lighting plan revised areas.pdf PDF
NSSL 0230.TIF TIF image
NSSL 0228.TIF TIF image
Ballast selection list20090819.pdf PDF
NSSL 0227.TIF TIF image
Amendment 1 in PDF.pdf PDF
Pre-bid walk through attendance list Ft Collins Lighting.pdf PDF
Lighting Spreadsheet 20090818 revision 4WCP.XLSX XLSX spreadsheet
NSSL 0234.TIF TIF image
NSSL 0232.TIF TIF image
Lithonia 20 20C fixtrures.pdf.pdf PDF
WAL-14 spec.pdf.pdf PDF
M-2x4.pdf.pdf PDF
IMH1.pdf.pdf PDF
Wage Determination Ft Collins CO.pdf PDF
Buy American excepted material or components.pdf PDF
Lithonia 20C 20fixtures 2020090721 1 .pdf PDF
IMH175C 2020090721 1 .pdf PDF
Copy of Lighting Spreadsheet 20090720 revision 2GMG.pdf PDF
AG-82HW-S-09-0019 - Replace Light Fixtures- Ft Collins - construction over 100K.DOC DOC document
M-2x4 2020090721 1 .pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Applications Stairwells, lobbies, hallways, open offices, small offices, retail, bathrooms.

Features An ADA-compliant wall luminaire. A fully perforated fascia fives the fixture a soft glow. The fixture is open on both the top and bottom of the fascia to give a wash of light both below and above while the specular kicker reflector pushes light out and away to wash the ceiling and illuminate the space. Dimming, emergency, and integrated occupancy sensor options are available.

Construction The housing, available in 2-, 3-, 4-, 6- or 8-foot standard lengths, and finish plates are made of 20-gauge steel.

Finish The standard exterior body color is textured matte white (TMW) or optional gloss white (YGW) using polyester powder paint. Refer to ordering matrix for optional metal finishes or refer to Defining Section for optional paint colors. Optional brushed aluminum fixture body will have flat finish plates with black paint finish unless another color is specified.

Electrical T8 fixtures have instant-start electronic ballasts with less than 20% THD. T5 fixtures have programmed-start electronic ballasts with less than 10% THD. Fixtures are U.L. Damp labeled and I.B.E.W. manufactured. Maximum ballast size available: 2 3/8" width x 1 1/2" height.

Mounting Fixture is to be mounted directly to a wall or surface-mounted on ceilings.

Options EML: emergency battery (T8=600-700 lumens, T5 =600- 700 lumens); EMH: emergency battery (T8=1100-1400 lumens, T5 =1100-1400 lumens): DM: dimming (consult factory); RSE: rapid-start electronic; 10THD: ballast with <10% total harmonic distortion; B_:

specific ballast, specify manufacturer and catalog number (consult factory); FH: fixture fusing (slow blow); QC: quick-connect circuit assemblies; OCO: S-Occ™Integrated Occupancy System – all lamps on/off; OC2C: S-Occ™ - one lamp sensored, one lamp on constantly;

OCDM: S-Occ™ - dim to standby mode.

Type

Job Name

Catalog Number

P

WAL-14

SD

Prudential Lighting phone 213.746.0360 fax 213.741.8590 www.prulite.com

Wall Mount

7"

4" nominal length

02'

03'

04'

06'

08'

R__*

*row length lamp rows

1T8

2T8

1T5

2T5

1T5HO

2T5HO

circuiting

SC single circuit

DC* dual circuit (in-line)

*2T8 only voltage

MVB*

multi-volt ballast

*120-277 body style

P* perforated

SD solid

*standard options

EML*

EMH*

DM

RSE

10THD

B__

FH

QC

OCO*

OC2C*

OCDM*

*consult factory for fixture lengths < 4� mounting

SUR† surface ceiling

WM* direct to wall

VWM† vertical wall mount

*standard †kicker reflector is not supplied

WAL-14

ordering color/finish

TMW* textured matte white

YGW gloss white

Y__ premium color

CC custom color

BAL† brushed aluminum

GLV galvanized

*standard †SD only- will have black painted finish plates series

WAL-14 » Wal l Mount

Adjoining Detail installation

Mounting Locations

Prudential Lighting 1737 E. 22nd St. Los Angeles, CA 90058 phone 213.746.0360 fax 213.741.8590 www.prulite.com

1.0' 2.0' 3.0' 4.0' 5.0' 6.0' 7.0' 8.0' 9.0'

1.0' 2.0' 3.0' 4.0' 5.0' 6.0' 7.0' 8.0' 9.0'

8.0'

7.0'

6.0'

5.0'

4.0'

3.0'

2.0'

1.0'

2.0'

41.2 50.1 48.9 39.9 25.6 25.6 39.9 48.9 50.1 41.2

25.3 28.3 28.5 27.3 25.6 25.6 27.3 28.5 28.3 25.3

9.0'

10.0'

Reflectances used: 80/50/20 Average Illuminance/Horizontal Grid (30" A.F.F.)

Ceiling Uniformity/Horizontal Grid (Ceiling Surface) small office application 10' x 12' x 9' small office layout

1.0' 2.0' 3.0' 4.0' 5.0' 6.0' 7.0'

1.0' 2.0' 3.0' 4.0' 5.0' 6.0' 7.0'

8.0'

7.0'

6.0'

5.0'

4.0'

3.0'

2.0'

1.0'

2.0'

41.0 49.9 49.9 37.5 20.4 13.9 11.1 9.9

17.7 20.1 21.2 20.6 19.2 17.4 15.6 13.8

9.0'

8.0'

Reflectances used: 80/50/20 Average Illuminance/Horizontal Grid (0" A.F.F.)

Ceiling Uniformity/Horizontal Grid (Ceiling Surface) corridor application 8' x 20' x 9' corridor layout

24", 36" or 48"

5" 5"

5"5" 36" or 48" 26" or 38"

18" or 24"

72" or 96"

In an effort to continually provide the highest quality products, Prudential reserves the right to change design specifications and/or materials, without notice.

Zonal Lumen Summary

Luminance Summary (cd/m2)

Coefficients of Utilization (%) Zone % Lamp % Luminaire

Angle 0° 45° 90°

Floor effective floor cavity reflectance = Ceiling 80 70 50 Wall 70 50 30 10 70 50 30 10 50 30 10

RCR

Vertical Ho r i z on t a l Ang l e Output Angle 0° 22.5° 45° 67.5° 90° Lumens

Candlepower Summary photometric data

150°

120°

90°

60°

30°

Report # D=39.0% I=6i.0% Lamp Lumens: Input Watts: 60

LSIi5373

WAL-14-P-2T8-04-TMW

0 543 543 543 543 543 5 537 531 506 502 488 24 15 515 468 400 367 342 58 25 473 381 275 249 249 73 35 414 278 215 239 253 83 45 338 176 193 251 283 90 55 251 125 186 279 334 99 65 158 83 200 332 396 111 75 71 61 223 371 441 120 85 7 61 234 393 461 125 90 0 62 232 391 458 95 21 65 232 389 455 126 105 144 102 227 371 435 131 115 305 230 243 337 394 144 125 466 380 319 366 387 168 135 624 537 444 446 438 189 145 763 700 584 576 538 194 155 874 813 731 699 670 173 165 952 918 859 840 821 123 175 991 986 965 960 955 46 180 990 990 990 990 990

0-90 25.59 39.00 90-180 40.02 61.00

65.6%

45 6623 1652 1831 55 6063 1474 1926 65 5180 1471 2071 75 3801 1541 2153 85 1112 1562 2181

.20

0 69 69 69 69 62 62 62 62 51 51 51 1 62 58 55 53 56 53 50 48 43 41 39 2 56 50 46 42 50 46 42 39 37 34 32 3 51 44 39 35 46 40 36 32 33 29 27 4 46 39 34 30 42 35 31 27 29 25 23 5 42 34 29 25 38 31 27 23 26 22 19 6 39 31 25 21 35 28 23 20 23 19 17 7 36 28 22 19 32 25 21 17 21 17 14 8 33 25 20 16 30 23 18 15 19 15 13 9 31 23 17 14 28 21 16 13 17 13 11 10 28 20 16 13 26 19 14 12 15 12 10

Efficiency =

2-8' Rows on 10' Centers – WAL-14-P-2T8-TMW

Overall Suspension Average Illuminance Ceiling Uniformity Watts/ ceiling to center of lamp maintained CLLF = .70D between fixtures Square Foot

C30� A.F.F.D

24" 23.0 FC 2.0 : 1 2.0

20' Single Fixture – WAL-14-P-2T8-TMW

Overall Suspension Average Illuminance Max : Min Watts/ ceiling to center of lamp maintained CLLF = .70D C0� A.F.F.D Square Foot

C0� A.F.F.D

24" 15.9 FC 2.2 : 1 1.8

Prudential reserves the right to change design specifications or materials without notice.

Prudential Lighting phone 213.746.0360 fax 213.741.8590 www.prulite.com planning informationcontrols options

Applications: Stairwells, corridors, storage rooms

System Components:

High quality wall-mounted luminaires - Snap, Wal-12, Wal-14, or P-1220

Fixture-integrated ultrasonic occupancy sensor and power pack by WattStopper/Legrand;

Program rapid start, 0-10V dimming, or bi-level ballasts for T5 specifications.

Specifications:

Fixtures fitted with S-Occ™ ship from our factory pre-calibrated with a 15-minute delay. You may specify a delay of up to 30 minutes, in 5-minute increments.

Fixtures specified to dim to standby mode (OCDM) will dim to the minimum level the ballast allows.

Specifying:

Choose your mode of operation:

OCO all lamps on/off using program rapid start ballast OC2C one lamp sensored, one lamp on (2 lamp only) OCDM dims to standby mode.

Sample part number:

WAL14-P-2T8-04’-TMW-SC-120-WM-OCDM

Describes a perforated wall-mounted 4-foot Wal14 with textured matte white finish, with Occupancy sensor that dims to 10% standby mode. T5 specifications use a bi-level ballast that dims to 50% standby mode.

The range of the ultrasonic sensor is about 20 feet from the face of the wall, and 12 feet on either side of the center. Obstacles such as furniture or partitions, wall, ceiling and floor treatments can cause the coverage area to be less or more. A 20% overlap in coverage is recommended.

» WAL-14Wal l Mount

S-OCC™ Small Space and Stair

Prudential reserves the right to change design specifications or materials without notice.

Prudential Lighting 1737 E. 22nd St. Los Angeles, CA 90058 phone 213.746.0360 fax 213.741.8590 www.prulite.com

WAL-14 » Wal l Mount» installation

Testing the Sensor:

1) Before testing or making adjustments, install furni-ture, turn lighting circuits on, and set HVAC systems to the overridden/ on position. VAV systems should be set to their highest airflow.

2) Activate the “Test Mode” using the test mode button.

3) Move out of the controlled area – the lights will turn off in about 5 seconds from the last flash of the LED.

If the LED continues to flash the sensor is detecting some kind of movement. Change the sensitivity adjustment to a lower setting (a few degrees counterclockwise) and repeat this step until the LED does not flash and the lights turn off.

4) Walk into the controlled area. If the lights don’t turn on, increase the sensitivity (a few degrees clockwise) and try again. Repeat this procedure until the LED does not flash and the lights turn off. If the lights turn off while the room is occupied, it may be necessary to increase the sensitivity.

5) Allow the test period to expire (5 minutes) or push the test button again. The sensor will now be in its operating mode.

Lamp Burn-In Mode:

Press and hold the Test Mode button for 5 seconds to start the Lamp Burn-In mode. This function initiates a 72-hour lamp burn-in period. The lamps will stay on continuously for 72 hours regardless of occupancy status. The LED flashes rapidly and continuously for the full period. After 72 hours, the sensor returns to normal function. To turn off the burn-in mode, momentarily push the test mode button again.

LED

Ultrasonic Transducer

Test Mode Button

Sensitivity Setting Occupancy Mode Switch

Wal-14 Type:
Wal-14 Job name:
Wal-14 body style:
Wal-14 Lamp rows:
Wal-14 Nominal length:
Wal-14 Color/finish:
Wal-14 Circuiting:
Wal-14 voltage:
Wal-14 mounting:
Wal-14 options:
Wal-14 Catalog Number: