Lighting Spreadsheet 20090818 revision 4WCP.XLSX
XLSX spreadsheet 57 KB Posted
- Solicitation number
- AG-82HW-S-09-0019
About this file
Lighting Spreadsheet 20090818 revision 4WCP
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Abstract of Bids S-09-0019.pdf | ||
| Amendment 2.pdf | ||
| NSSL 0231.TIF | TIF image | |
| NSSL 0229.TIF | TIF image | |
| NSSL 0233.TIF | TIF image | |
| 2002 lighting plan revised areas.pdf | ||
| NSSL 0230.TIF | TIF image | |
| NSSL 0228.TIF | TIF image | |
| Ballast selection list20090819.pdf | ||
| NSSL 0227.TIF | TIF image | |
| Amendment 1 in PDF.pdf | ||
| Pre-bid walk through attendance list Ft Collins Lighting.pdf | ||
| NSSL 0234.TIF | TIF image | |
| NSSL 0232.TIF | TIF image | |
| Lithonia 20 20C fixtrures.pdf.pdf | ||
| WAL-14 spec.pdf.pdf | ||
| M-2x4.pdf.pdf | ||
| IMH1.pdf.pdf | ||
| Wage Determination Ft Collins CO.pdf | ||
| Buy American excepted material or components.pdf | ||
| Lithonia 20C 20fixtures 2020090721 1 .pdf | ||
| IMH175C 2020090721 1 .pdf | ||
| Copy of Lighting Spreadsheet 20090720 revision 2GMG.pdf | ||
| AG-82HW-S-09-0019 - Replace Light Fixtures- Ft Collins - construction over 100K.DOC | DOC document | |
| WAL-14_specDL 2020090721 1 .pdf | ||
| M-2x4 2020090721 1 .pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
Location Room Number Fixture Type Length Quantity Ballast/ Fixture Remove Existing Fixture Existing Ballast Subtotal to be Removed Bulbs/ Fixture Existing Bulb Subtotal to be Removed Retrofit single pin ends to "tombstone" bi-pin ends for T8 Bulbs Install 4' T8 Bulbs Install 3' T-8 Bulbs Install 4' U shaped T8 bulbs Install Lithonia C 2 32 277 GEB10RS Install Lithonia TC225-277-GEB10RS or equal Install Prudential WAL-14 P 2T8 04' TMW SC 277 SUR OC2C or equal Install Prudential WAL-14 P 2T8 04' TMW SC 277 WM OC2C or equal Install Metal Halide Pulse Start ballasts and lamps. Replace trim rings Install Rab Lighting WPC1FCH70 Install Rab Lighting WP2C100 Install Lithonia 2M 2 32 A12125 277 GEB10RS Install Program Start Ballast Upgrade w/ Harris Lighting retrofit MKSR-84-44-T8-W or equal Install Occupancy Sensor Watt Stopper WS DT-205 or equal Install Occupancy Sensor Watt Stopper WS PW-100 or equal Install Occupancy Sensors Watt Stopper WT-1100 or equal Install Occupancy Sensor Watt Stopper WS UW-100 or equal Install Occupancy Sensor Watt Stopper DT-305 or equal Install Occupancy Sensor Watt Stopper WS TS-400 or equal Install Occupancy Sensor Watt Stopper WS-200 or equal Install Occupancy Sensors Watt Stopper DW-100 or equal Install Occupancy Sensor Watt Stopper TS-200 or equal Install Occupancy Sensor Watt Stopper WPIR or equal Install Occupancy Sensor Watt Stopper W-2000H or equal Action to be taken Additional Controls & Information Comments & Legend for Actions
| Vault | ||||||||||||||||||||||||||||||||||||
| B01 | F1 | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | RXLB&UWRT8&PSB | Replace existing lamps and ballast and upgrade with retrofit T8 bulbs and Program start ballast (RXLB&UWRT8&PSB) | |||||||||||||||||||||||||
| B02 | D | (4’) | 3 | 1 | 3 | 2 | 6 | 6 | 3 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| B03 | H | (8’) | 48 | 1 | 48 | 2 | 96 | 192 | 48 | RXLB&UWHLR,T8,PSB | Replace existing lamps and ballast and upgrade with Harris Lighting 8' to 2x4' retrofit kit T8 bulbs and Program start ballast (RXLB&UWHLR,T8&PSB) | |||||||||||||||||||||||||
| 146 | D | (4’) | 3 | 1 | 3 | 2 | 6 | 6 | 3 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| 147 | F1 | (4’) | 3 | 1 | 3 | 2 | 6 | 6 | 3 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| 148 | H | (8’) | 48 | 1 | 48 | 2 | 96 | 192 | 48 | RXLB&UWHLR,T8,PSB | ||||||||||||||||||||||||||
| 235 | D | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| AA | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | RXLB&UWRT8&PSB | |||||||||||||||||||||||||||
| 236 | F1 | (4’) | 3 | 1 | 3 | 2 | 6 | 6 | 3 | RXLB&UWRT8&ISB | Cold (0° F) Rated Ballasts to be used, relocate west light obscured by ductwork to area over west compressor | |||||||||||||||||||||||||
| 302 | F1 | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| 303 | EE | (8’) | 2 | 2 | 4 | 4 | 8 | 16 | 8 | 2 | RXLB&UWHLR,T8,ISB | Cold (0° F) Rated Ballasts to be used | ||||||||||||||||||||||||
| 304 | D | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| 305 | F | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| Stair 3 | F | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | RXF&RPWPLT8 4' SUR | Relocation of light on 3rd floor landing may be needed to allow for door operation, Verify in field | Remove existing fixture and replace with Prudential Lighting WAL-14 P 2T8 04' TMW SC 277 SUR OC2C or similar (RXF&RPWPLT8 4' SUR) | ||||||||||||||||||||||||
| I1 | (6’) | 4 | 2 | 4 | 4 | 16 | 8 | 4 | RXF&RPWPLT8 4' WM | Remove existing fixture and replace with Prudential Lighting WAL-14 P 2T8 04' TMW SC 277 WM OC2C or similar (RXF&RPWPLT8 4' WM) | ||||||||||||||||||||||||||
| Stair 4 | F | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | RXF&RPWPLT8 4' SUR | ||||||||||||||||||||||||||
| I1 | (6’) | 4 | 2 | 4 | 4 | 16 | 8 | 4 | RXF&RPWPLT8 4' WM | |||||||||||||||||||||||||||
| Elevator | 4' | 6 | 1 | 6 | 1 | 6 | 6 | 6 | 1 | RXLB&UWRT8&PSB | IOS WS DT-205 | Install Occupancy Sensor-Watt Stopper DT-205 (IOS- WS DT-205) | ||||||||||||||||||||||||
| Subtotal | 145 | 16 | 131 | 304 | 16 | 480 | 0 | 0 | 0 | 0 | 8 | 8 | 0 | 0 | 0 | 0 | 31 | 98 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Lamps 480 @ 4';16 New fixtures; 98 retrofit from 2 bulb 8' to use 4-4' bulbs |
| North Wing | |||||||||||||||||||||||||||||||||
| 1st Floor | |||||||||||||||||||||||||||||||||
| 101 | F | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS- WS PW-100 | Replace existing lamps and ballast and upgrade with retrofit T8 bulbs and Program start ballast (RXLB&UWRT8&PSB) Install Occupancy Sensor, Watt Saver PW-100 (IOS- WS PW-100) | ||||||||||||||||||||
| 102 | Z | (4’) | 2 | 1 | 2 | 3 | 6 | 6 | 2 | 2 | RXLB&UWRT8&PSB | IOS-WS WT-1100 | Install Occupancy Sensor-Watt Stopper WT-1100 (IOS- WS WT-1100) | ||||||||||||||||||||
| P | (6’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | REMXF&RPWL&T8 | Remove existing fixture and replace with Lithonia TC225-277-GEB10RS fixture with Program Start ballast, T-8 bulbs (REMXF&RPWL&T8) | |||||||||||||||||||||||
| 103 | Z | (4’) | 2 | 1 | 2 | 3 | 6 | 6 | 2 | 2 | RXLB&UWRT8&PSB | IOS-WS WT-1100 | |||||||||||||||||||||
| P | (6’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | REMXF&RPWL&T8 | ||||||||||||||||||||||||
| 104 | F | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS UW-100 | Install Occupancy Sensor- Watt Stopper UW-100 (IOS-WS UW-100) | ||||||||||||||||||||
| 107 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | Install Occupancy Sensor-Watt Stopper DT-305 (IOS-WS-DT-305) | ||||||||||||||||||||
| 108 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 109 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 110 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 111 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 112 | A | (4’) | 4 | 2 | 8 | 3 | 12 | 12 | 8 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 113 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 114 | A | (4’) | 6 | 2 | 12 | 3 | 18 | 18 | 12 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 115 | A | (4’) | 2 | 2 | 4 | 3 | 6 | 6 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 116 | A | (4’) | 6 | 2 | 12 | 3 | 18 | 18 | 12 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 118 | A | (4’) | 3 | 2 | 6 | 3 | 9 | 9 | 6 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 119 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 121 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 122 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 123 | A | (4’) | 6 | 2 | 12 | 3 | 18 | 18 | 12 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 124 | AA | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 126 | AA | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 127 | E | (4’) | 6 | 1 | 6 | 2 | 12 | 12 | 6 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 128 | D | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS-WS UW-100 | |||||||||||||||||||||
| 129 | A | (4’) | 5 | 2 | 10 | 3 | 15 | 15 | 10 | 1 | RXLB&UWRT8&PSB | IOS-WS DT305 | |||||||||||||||||||||
| 130 | A | (4’) | 17 | 2 | 34 | 3 | 51 | 51 | 34 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | Install Occupancy Sensor- Qty 2, wired in parallel, Watt Stopper DT-305 (IOS- Qty 2, w in p, WS DT-305) | ||||||||||||||||||||
| (2’) | 2 | 2 | 4 | 2 | 4 | 4 | 4 | RXLB&UWRT8&PSB | 2' fixtures utilize "U" shaped 4' bulbs | ||||||||||||||||||||||||
| 131 | D | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | RXLB&UWRT8&PSB | |||||||||||||||||||||||
| 132 | A | (4’) | 20 | 2 | 40 | 3 | 60 | 60 | 40 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||
| (2’) | 2 | 2 | 4 | 2 | 4 | 4 | 4 | RXLB&UWRT8&PSB | 2' fixtures utilize "U" shaped 4' bulbs | ||||||||||||||||||||||||
| 133 | A | (4’) | 20 | 2 | 40 | 3 | 60 | 60 | 40 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||
| (2’) | 2 | 2 | 4 | 2 | 4 | 4 | 4 | RXLB&UWRT8&PSB | 2' fixtures utilize "U" shaped 4' bulbs | ||||||||||||||||||||||||
| 134 | A | (4’) | 20 | 2 | 40 | 3 | 60 | 60 | 40 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||
| (2’) | 2 | 2 | 4 | 2 | 4 | 4 | 4 | RXLB&UWRT8&PSB | 2' fixtures utilize "U" shaped 4' bulbs | ||||||||||||||||||||||||
| 135 | A | (4’) | 20 | 2 | 40 | 3 | 60 | 60 | 40 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||
| (2’) | 2 | 2 | 4 | 2 | 4 | 4 | 4 | RXLB&UWRT8&PSB | 2' fixtures utilize "U" shaped 4' bulbs | ||||||||||||||||||||||||
| 137 | A | (4’) | 20 | 2 | 40 | 3 | 60 | 60 | 40 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||
| (2’) | 2 | 2 | 4 | 2 | 4 | 4 | 4 | RXLB&UWRT8&PSB | 2' fixtures utilize "U" shaped 4' bulbs | ||||||||||||||||||||||||
| 138 | AA | (4') | 6 | 1 | 6 | 2 | 12 | 12 | 6 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 139 | AA | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 140 | AA | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 141 | AA | (4') | 3 | 1 | 3 | 2 | 3 | 1 | RXB&UWT8 PSB | IOS-WS W-2000H | |||||||||||||||||||||||
| 144 | AA | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS- WS PW-100 | |||||||||||||||||||||
| 145 | AA | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||
| 145A | AA | (4') | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS- WS PW-100 | |||||||||||||||||||||
| 149 | H | (8’) | 2 | 1 | 2 | 2 | 4 | 8 | 2 | 1 | RXLB&UWHLR,T8,PSB | IOS, WS TS-400 | Replace existing lamps and ballast and upgrade with Harris Lighting retrofit MKSR-84-44-T8-W T8 bulbs and program start ballast. Note: one strip light is on circuit H1B-13, the other is on emergency lighting circuit and is currently not switched. Add additional Switch to control. | ||||||||||||||||||||
| 150 | F | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS, WS TS-400 | Install Occupancy Sensor Watt Saver TS-400 (IOS, WS TS-400) | ||||||||||||||||||||
| 151 | H | (8’) | 3 | 1 | 3 | 2 | 6 | 12 | 3 | 1 | RXLB&UWHLR,T8,PSB | IOS, WS TS-400 | Note: Demo existing S3 located on sheet E17@K-11.6, convert switch at K.-10.6 to S1 | ||||||||||||||||||||
| Subtotal | 247 | 2 | 406 | 641 | 0 | 623 | 8 | 24 | 0 | 2 | 0 | 0 | 401 | 5 | 0 | 3 | 4 | 2 | 35 | 3 | 0 | 0 | 0 | 0 | 1 | Lamps 8 @ 3'; 623 @ 4'; 24 @ 4' U shaped / 2 New Lithonia fixtures / 5 Harris retrofits / 46 occupancy sensors in 40 rooms |
| South Wing | |||||||||||||||||||||||||||||||||||
| 1st Floor | 155 | (4’) | 18 | 2 | 36 | 54 | 0 | 36 | 2 | RXB&UWT8 PSB | IOS- Qty 2, w in p, WS DT-305 | Remove existing ballast and upgrade to program start ballast (RXB&UWT8 PSB) | |||||||||||||||||||||||
| Room | 157 | H | (8’) | 2 | 1 | 2 | 2 | 4 | 8 | 2 | 1 | RXLB&UWHLR,T8,PSB | IOS, WS DT-305 | Replace existing lamps and ballast and upgrade with retrofit T8 bulbs and Program start ballast | |||||||||||||||||||||
| 158 | (4’) | 9 | 2 | 18 | 3 | 0 | 18 | 1 | RXB&UWT8 PSB | IOS-WS DT-305 | |||||||||||||||||||||||||
| 159 | (4’) | 14 | 2 | 28 | 3 | 0 | 28 | 2 | RXB&UWT8 PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||||
| 162 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS, WS DT-205 | |||||||||||||||||||||||
| 163 | GG | (4') | No changes needed | ||||||||||||||||||||||||||||||||
| HH | (4') | No changes needed | |||||||||||||||||||||||||||||||||
| 163A | Z | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS-WS UW-100 | |||||||||||||||||||||||
| 163B | Z | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS, WS UW-100 | |||||||||||||||||||||||
| 164 | F1 | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS, WS WS-200 | Install Occupancy Sensor- Watt Stopper WS-200 (IOS, WS WS-200) | ||||||||||||||||||||||
| 165 | F1 | (4’) | 3 | 1 | 3 | 2 | 6 | 6 | 3 | 1 | RXLB&UWRT8&PSB | IOS, WS TS-200 | Install Occupancy Sensor- Watt Stopper TS-200 (IOS, WS TS-200) | ||||||||||||||||||||||
| 166 | D | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS, WS TS-200 | |||||||||||||||||||||||
| 167 | F1 | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||
| H | (8’) | 4 | 1 | 4 | 2 | 8 | 16 | 4 | RXLB&UWHLR,T8,PSB | ||||||||||||||||||||||||||
| 168 | 8 | 1 | 8 | 2 | 0 | 0 | 8 | 1 | RXB&UWT8 PSB | IOS, WS WPIR | |||||||||||||||||||||||||
| 169 | 2 | 1 | 2 | 2 | 0 | 0 | 2 | 2 | RXB&UWT8 PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||||
| 170 | Z | (4’) | 2 | 1 | 2 | 3 | 6 | 6 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS WT-1100 | |||||||||||||||||||||||
| G | (8’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | RXLB&UWHLR,T8,PSB | ||||||||||||||||||||||||||
| 172 | Z | (4’) | 2 | 1 | 2 | 3 | 6 | 6 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS WT-1100 | |||||||||||||||||||||||
| G | (8’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | RXLB&UWHLR,T8,PSB | ||||||||||||||||||||||||||
| 173 | A | (4’) | 4 | 2 | 8 | 3 | 12 | 12 | 8 | 1 | RXLB&UWRT8&PSB | IOS, WS DT-205 | |||||||||||||||||||||||
| 174 | A | (4’) | 2 | 2 | 4 | 3 | 6 | 6 | 4 | 1 | RXLB&UWRT8&PSB | IOS, WS DT-205 | Reconnect switch (H1A-5) to north fixture, center single bulb. South fixture, center bulb to remain on emergency lighting circuit | ||||||||||||||||||||||
| Suspend | (4') | 1 | 1 | 1 | 2 | 0 | 0 | 1 | RXB&UWT8 PSB | re-feed existing pendant light from emergency circuit to control from switch for north fixture, center single bulb | |||||||||||||||||||||||||
| 175 | BB | Metal Halide, down throw | 12 | 12 | 12 | RXLB&UPulSBL, RTR, RFL | Replace Existing Metal Halide lamps and Ballasts and Upgrade to Electronic Pulse start ballasts and ceramic metal halide bulbs. Replace existing trim rings and resecure. Re feed lights to create two separate switched light banks. Re-use Switch for "Q". (RXLB&UPulSBL, RTR, RFL) | ||||||||||||||||||||||||||||
| Q | Metal Halide,up throw | 4 | 4 | DL&ABwW&C | Demo lights and abandon box with wire and cover with steel plate for future modification as needed (DL&ABwW&C) Box is hidden in sconce | ||||||||||||||||||||||||||||||
| P | (6') | 3 | 1 | 3 | 2 | 6 | 8 | 4 | RMXF&ILC232-T8 | Remove existing fixtures and replace with Lithonia C 2 32 277 GEB10RS (RMXF&ILC232-T8) | |||||||||||||||||||||||||
| F | (4') | 4 | 1 | 4 | 2 | 8 | 8 | 4 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| 176 | A | (4’) | 4 | 2 | 8 | 3 | 12 | 12 | 8 | 1 | RXLB&UWRT8&PSB | IOS, WS DT-305 | |||||||||||||||||||||||
| 177 | A | (4’) | 6 | 2 | 12 | 3 | 18 | 18 | 12 | 1 | RXLB&UWRT8&PSB | IOS, WS DT-305 | |||||||||||||||||||||||
| 178 | A | (4’) | 4 | 2 | 8 | 3 | 12 | 12 | 8 | 1 | RXLB&UWRT8&PSB | IOS, WS DT-305 | |||||||||||||||||||||||
| 179 | A | (4’) | 4 | 2 | 8 | 3 | 12 | 12 | 8 | 1 | RXLB&UWRT8&PSB | IOS, WS DT-305 | |||||||||||||||||||||||
| Subtotal | 124 | 7 | 182 | 140 | 158 | 0 | 0 | 4 | 0 | 0 | 0 | 12 | 0 | 0 | 162 | 8 | 3 | 0 | 2 | 2 | 14 | 0 | 1 | 0 | 2 | 1 | 0 | Lamps: 158 @ 4' / Abandon 4 fixtures / 4 new fixtures / 8 Harris retrofit / Upgrade 12 metal halide ballasts/ 25 Occupancy Sensors in 21 rooms |
| North Wing | |||||||||||||||||||||||||||||||||||
| 2nd Floor | |||||||||||||||||||||||||||||||||||
| 202 | E | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 203 | A | (4’) | 6 | 2 | 12 | 3 | 18 | 18 | 12 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 204 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 205 | B | (4’) | 4 | 1 | 4 | 2 | 8 | 8 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 207 | E | (4’) | 6 | 2 | 12 | 3 | 18 | 18 | 12 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 208 | A | (4’) | 4 | 2 | 8 | 3 | 12 | 12 | 8 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 209 | A | (4’) | 4 | 2 | 8 | 3 | 12 | 12 | 8 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 210 | E | (4’) | 16 | 2 | 32 | 3 | 48 | 48 | 32 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 211 | E | (4’) | 3 | 2 | 6 | 3 | 9 | 9 | 6 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 212 | E | (4’) | 2 | 2 | 4 | 3 | 6 | 6 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 213 | E | (4’) | 2 | 2 | 4 | 3 | 6 | 6 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 214 | A | (4’) | 3 | 2 | 6 | 3 | 9 | 9 | 6 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 215 | A | (4’) | 16 | 2 | 32 | 3 | 48 | 48 | 32 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 216 | D | (4’) | 3 | 1 | 3 | 2 | 6 | 6 | 3 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 217 | D | (4’) | 6 | 1 | 6 | 2 | 12 | 12 | 6 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 218 | H | (8’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | RXLB&UWHLR,T8,PSB | |||||||||||||||||||||||||
| (6') | 26 | 1 | 26 | 1 | 26 | 52 | 26 | Remove existing fixtures and replace with 26 -twin tube T-8 with instant start ballast | Install 2 switches inside room to control banks individually. | ||||||||||||||||||||||||||
| 219 | H | (8’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | RXLB&UWHLR,T8,PSB | |||||||||||||||||||||||||
| (6') | 26 | 1 | 26 | 1 | 26 | 52 | 26 | Remove existing fixtures and replace with 26 -twin tube T-8 with instant start ballast | Install 2 switches inside room to control banks individually. | ||||||||||||||||||||||||||
| 220 | H | (8’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | RXLB&UWHLR,T8,PSB | |||||||||||||||||||||||||
| (6') | 26 | 1 | 26 | 1 | 26 | 52 | 26 | Remove existing fixtures and replace with 26 -twin tube 4' T-8 with instant start ballast | Install 2 switches inside room to control banks individually. | ||||||||||||||||||||||||||
| 221 | B | (4') | 6 | 1 | 6 | 2 | 12 | 12 | 6 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-305 | |||||||||||||||||||||||
| 222 | (4') | 18 | 2 | 36 | 2 | 36 | 36 | 36 | 18 | RXLB&UWRT8&PSB | IOS- WS DW-100 | Install Occupancy Sensor, Watt Stopper DW-100 (IOS ws DW-100) | |||||||||||||||||||||||
| 228 | A | (4') | 1 | 2 | 2 | 3 | 3 | 3 | 2 | 1 | RXLB&UWRT8&PSB | IOS- WS PW-100 | |||||||||||||||||||||||
| 229 | A | (4') | 18 | 2 | 36 | 3 | 54 | 54 | 36 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||
| 231 | A | (4') | 20 | 2 | 40 | 3 | 60 | 60 | 40 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||
| 232 | A | (4') | 22 | 2 | 44 | 3 | 66 | 66 | 44 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||
| 233 | A | (4') | 21 | 2 | 42 | 3 | 63 | 63 | 42 | 2 | RXLB&UWRT8&PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||
| 239 | H | (8') | 6 | 1 | 6 | 2 | 12 | 24 | 6 | RXLB&UWHLR,T8,PSB | Install 2 switches inside room to control banks individually. | ||||||||||||||||||||||||
| 240 | H | (8') | 2 | 1 | 2 | 2 | 4 | 8 | 2 | RXLB&UWHLR,T8,PSB | |||||||||||||||||||||||||
| Subtotal | 276 | 78 | 360 | 72 | 618 | 0 | 718 | 0 | 0 | 78 | 0 | 0 | 0 | 0 | 0 | 0 | 349 | 11 | 0 | 1 | 0 | 0 | 24 | 0 | 0 | 18 | 0 | 0 | Lamps 718 @ 4' / 11 Harris Retrofit / 78 New fixtures / 26 Occupancy Sensors in 22 rooms |
| South Wing | |||||||||||||||||||||||||||||||||||
| 2nd Floor | 242 | (4’) | 9 | 2 | 18 | 3 | 0 | 18 | 1 | RXB&UWT8 PSB | IOS-WS DT-305 | ||||||||||||||||||||||||
| 242A | (4’) | 3 | 2 | 6 | 3 | 0 | 6 | 1 | RXB&UWT8 PSB | IOS-WS DT-305 | |||||||||||||||||||||||||
| 243 | (4’) | 21 | 2 | 42 | 3 | 0 | 42 | 2 | RXB&UWT8 PSB | IOS- Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||||
| (4’) | 1 | 1 | 1 | 2 | 0 | 1 | |||||||||||||||||||||||||||||
| 244 | (4’) | 11 | 2 | 22 | 3 | 0 | 22 | 2 | RXB&UWT8 PSB | IOS-Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||||
| 246 | H | (8’) | 12 | 1 | 12 | 2 | 24 | 48 | 12 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-205 | |||||||||||||||||||||||
| 247 | (4’) | 9 | 2 | 18 | 3 | 0 | 18 | 2 | RXB&UWT8 PSB | IOS-Qty 2, w in p, WS DT-305 | |||||||||||||||||||||||||
| 248 | AA | (4’) | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | RXLB&UWRT8&PSB | IOS-WS WT-1100 | |||||||||||||||||||||||
| P | (6’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | REMXF&RPWL&T8 | ||||||||||||||||||||||||||
| 248A | AA | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-205 | ||||||||||||||||||||||||
| B | 1 | 2 | 1 | 3 | 3 | 2 | 1 | RXF&RP L2M2&T8 | Remove existing fixture and replace with Lithonia 2M 2 32 A12125 277 GEB10RS (RXF&RP L2M2&T8) | ||||||||||||||||||||||||||
| 249 | AA | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS WT-1100 | |||||||||||||||||||||||
| P | (6’) | 1 | 1 | 1 | 2 | 2 | 4 | 1 | REMXF&RPWL&T8 | ||||||||||||||||||||||||||
| 249A | AA | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 1 | RXLB&UWRT8&PSB | IOS-WS DT-205 | ||||||||||||||||||||||||
| 250 | A | (4’) | 2 | 2 | 4 | 3 | 6 | 6 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT305 | |||||||||||||||||||||||
| 251 | A | (4’) | 8 | 2 | 16 | 3 | 24 | 24 | 16 | 1 | RXLB&UWRT8&PSB | IOS-WS DT305 | |||||||||||||||||||||||
| 252 | A | (4’) | 2 | 2 | 4 | 3 | 6 | 6 | 4 | 1 | RXLB&UWRT8&PSB | IOS-WS DT305 | |||||||||||||||||||||||
| 253 | B | (4’) | 3 | 1 | 3 | 2 | 6 | 6 | 3 | RXLB&UWRT8&PSB | |||||||||||||||||||||||||
| B1 | (4’) | 3 | 2 | 6 | 2 | 6 | 6 | 6 | RXLB&UWRT8&PSB | ||||||||||||||||||||||||||
| Subtotal | 94 | 3 | 159 | 93 | 0 | 112 | 8 | 0 | 0 | 2 | 0 | 0 | 0 | 0 | 1 | 147 | 12 | 3 | 0 | 2 | 0 | 11 | 0 | 0 | 0 | 0 | 0 | Lamps 112 @ 4'; 8 @ 3' /12 Harris retrofit / 16 Occ Sensors in 13 rooms / |
| North Wing | ||||||||||||||
| 3rd Floor | 301 | H | (8’) | 24 | 1 | 24 | 2 | 48 | 96 | 24 | 2 | RXLB&UWHLR,T8,PSB | IOS- WS TS-400, Qty 2 | Note: Demo existing S3 located on sheet E21@M-5, convert switches at H.2-9 to S1 |
| North Wing Stairwells | ||||||||||||||||||||||||||||||||
| Stair | 1 | I1 | (6’) | 7 | 2 | 7 | 4 | 28 | 14 | 7 | RXF&RPWPLT8 4' WM | |||||||||||||||||||||
| 2 | I1 | (6’) | 3 | 2 | 3 | 4 | 12 | 6 | 3 | RXF&RPWPLT8 4' WM | ||||||||||||||||||||||
| F | (4’) | 2 | 1 | 2 | 2 | 4 | 4 | 2 | RXF&RPWPLT8 4' SUR | |||||||||||||||||||||||
| Elevator | Main Lobby | (4') | 6 | 1 | 6 | 1 | 6 | 6 | 6 | 1 | RXLB&UWRT8&PSB | IOS WS DT-205 | ||||||||||||||||||||
| Subtotal | 18 | 12 | 0 | 44 | 0 | 30 | 0 | 0 | 0 | 0 | 2 | 10 | 0 | 0 | 0 | 6 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Lamps 30 @ 4' / 12 Prudential WAL-14 |
| South Wing Stairwell | |||||||||||
| Stair | 5 | I1 | (6’) | 4 | 2 | 8 | 4 | 16 | 8 | 4 | RXF&RPWPLT8 4' WM |
| Exterior Lighting | Handrails | (4') | 8 | 1 | 8 | 1 | 8 | 8 | Remove existing lamps and ballasts. Replace with T-8 bulbs with new ballasts rated for low temperature start | Verify fixture qty and size | ||||||||||||||||||||||||||
| Door 95 (room 175) | 1 | 1 | RXF&RPWRABWP1FC70 | Convert to 277V fixture to be supplied by emergency lighting circuits, demo existing plugmold in lobby, repair wall & paint as necessary | Remove existing exterior light and motion sensor, replace with RAB Lighting WP1FCH70QT/ PCS Fully shielded, Full Cutoff wallpack with Daylight sensor (RXF&RPWRABWP1FC70) | |||||||||||||||||||||||||||||||
| Loading Dock | 2 | 2 | RXF&RPWRABWP2C100C | Verify voltage | Remove existing exterior light and motion sensor, replace with RAB Lighting WP2CH100QT , Cutoff wallpack (RXF&RPWRABWP2C100) | |||||||||||||||||||||||||||||||
| Subtotal | 8 | 3 | 8 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | 0 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||
| Note: Replacement Program start ballasts shall be Sylvania Quicktronic PROStart PSX or equivalent. | ||||||||||||||||||||||||||||||||||||
| Replacement bulbs shall be Octron XPS-841 bulbs or equivalent. Bulbs used in Room 218,219, 220 shall be Octron XPS-835 or other approved. |
Vault 145 16 131 304 16 480 0 0 0 0 8 8 0 0 31 98 1 0 0 0 0 0 0 0 0 0 0
North Wing 1st Floor 247 2 406 641 0 623 8 24 0 2 0 0 0 0 0 401 5 0 3 10 2 35 3 0 0 0 0 1
South Wing 1st Floor 124 7 182 140 158 0 0 4 0 0 0 12 0 0 162 8 3 0 2 2 14 0 1 0 2 1 0
North Wing 2nd Floor 276 78 360 618 0 718 0 0 78 0 0 0 0 0 0 0 349 11 0 1 0 0 24 0 0 18 0 0 0
South Wing 2nd Floor 94 3 159 93 0 112 8 0 0 2 0 0 0 0 0 1 147 12 3 0 2 0 11 0 0 0 0 0 0
North Wing 3rd Floor 24 24 48 0 96 0 0 0 0 0 0 0 0 0 0 0 24 0 0 0 0 0 2 0 0 0 0 0
| North Wing Stairwells | 18 | 12 | 6 | 44 | 0 | 30 | 0 | 0 | 0 | 0 | 2 | 10 | 0 | 0 | 0 | 0 | 6 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
| South Wing Stairwell | 4 | 4 | 16 | 0 | 8 | 0 | 0 | 0 | 0 | 0 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
| Exterior Lighting | 8 | 3 | 8 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | 0 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Base Bid Totals, which are approximate 940 125 1276 1912 16 2225 16 24 82 4 10 22 12 1 2 1 1104 158 8 4 14 4 84 5 1 18 2 1 1 1396
| Add/Alt 1 | ||||||||||||||
| Hallways | ||||||||||||||
| 1st Floor | North | B | 4' | 35 | 1 | 35 | 2 | 0 | 35 | 12 | RXB&UWT8 PSB; IOS WS W-2000H WIP | Install Occupancy Sensor Watt Stopper W-2000H wired in parallel (IOS WS W-2000H WIP) | ||
| B1 | 4' | 17 | 2 | 17 | 2 | 0 | 17 | RXB&UWT8 PSB; IOS WS W-2000H WIP | ||||||
| South | B | 4' | 8 | 1 | 13 | 2 | 0 | 13 | 4 | RXB&UWT8 PSB; IOS WS W-2000H WIP | ||||
| B1 | 4' | 5 | 1 | 5 | 2 | 0 | 10 | RXB&UWT8 PSB; IOS WS W-2000H WIP | ||||||
| 2nd Floor | North | B | 4' | 36 | 1 | 48 | 2 | 0 | 48 | 12 | RXB&UWT8 PSB; IOS WS W-2000H WIP | Add Additional ballast for single bulb emergency light operation | Wire second ballast to switched circuit leg | |
| B1 | 4' | 12 | 2 | 12 | 2 | 0 | 12 | RXB&UWT8 PSB; IOS WS W-2000H WIP | ||||||
| South | B | 4' | 6 | 1 | 6 | 2 | 0 | 6 | 5 | RXB&UWT8 PSB; IOS WS W-2000H WIP | ||||
| B1 | 4' | 3 | 2 | 3 | 2 | 0 | 3 | RXB&UWT8 PSB; IOS WS W-2000H WIP | ||||||
| Add Alt. 1 Totals | 122 | 0 | 139 | 0 | 144 | 33 |