Lithonia 20 20C fixtrures.pdf.pdf
PDF 172 KB Posted
- Solicitation number
- AG-82HW-S-09-0019
About this file
Lithonia 20 20C Fixtures
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Abstract of Bids S-09-0019.pdf | ||
| Amendment 2.pdf | ||
| NSSL 0231.TIF | TIF image | |
| NSSL 0229.TIF | TIF image | |
| NSSL 0233.TIF | TIF image | |
| 2002 lighting plan revised areas.pdf | ||
| NSSL 0230.TIF | TIF image | |
| NSSL 0228.TIF | TIF image | |
| Ballast selection list20090819.pdf | ||
| NSSL 0227.TIF | TIF image | |
| Amendment 1 in PDF.pdf | ||
| Pre-bid walk through attendance list Ft Collins Lighting.pdf | ||
| Lighting Spreadsheet 20090818 revision 4WCP.XLSX | XLSX spreadsheet | |
| NSSL 0234.TIF | TIF image | |
| NSSL 0232.TIF | TIF image | |
| WAL-14 spec.pdf.pdf | ||
| M-2x4.pdf.pdf | ||
| IMH1.pdf.pdf | ||
| Wage Determination Ft Collins CO.pdf | ||
| Buy American excepted material or components.pdf | ||
| Lithonia 20C 20fixtures 2020090721 1 .pdf | ||
| IMH175C 2020090721 1 .pdf | ||
| Copy of Lighting Spreadsheet 20090720 revision 2GMG.pdf | ||
| AG-82HW-S-09-0019 - Replace Light Fixtures- Ft Collins - construction over 100K.DOC | DOC document | |
| WAL-14_specDL 2020090721 1 .pdf | ||
| M-2x4 2020090721 1 .pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Catalog Number
Notes Type
Fluorescent
General-Purpose Strip
C 2', 3', 4', 6' or 8' length
1 or 2 lamps
FEATURES & SPECIFICATIONS
INTENDED USE
Ideal where high brightness and good illumination levels are required such as retail, light industrial and warehouses.
ATTRIBUTES
Fixture can be assembled with snap together components and requires no tools. Available in one lamp or two lamp configuration.
CONSTRUCTION
Heavy-duty channel, die-formed from code-gauge steel.
Sturdy channel cover secured by captive quarter-turn latch for easy access to wireway.
Combination endplate/channel connector furnished with each fixture.
FINISH
Five-stage iron phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts finished with high-gloss, baked white enamel.
ELECTRICAL SYSTEM
Thermally protected, resetting, Class P, UL Listed and CSA Certified ballast is standard. Sound rating depends on lamp/ballast combination.
AWM, TFN, THHN wire throughout, rated for required temperatures.
INSTALLATION
For unit or row installations, surface or suspended mounting.
LISTING
UL listed to US and Canadian safety standards. Optional: Mexico NOM.
WARRANTY
Guaranteed for one year against mechanical defects in manufacture.
Specifications subject to change without notice.
Specifications
Length: 24" (610) 36" (914) 48" (1219) 72" (1829) 96" (2438)
Width: 4-3/8" (111) Fixture Depth: 2-1/16" (52)
All dimensions are inches (millimeters).
L
W
D
Series
C General-purpose strip
For tandem double-length unit, add prefix T. Example: TC
Number of lamps
Not included.
Voltage
MVOLT1,2
Others available.
NOTES:
1 MVOLT standard for 120-277V applications, 50-60 mhz operation. Some options require voltage specified.
2 T8 lamps only.
3 Slimline lamps only.
4 Not available in slimline.
5 Order two for 8' fixtures.
Lamp type
T8 17 17W T8 (24") 25 25W T8 (36") 32 32W T8 (48")
96T8 59W T8 slimline (96") T12 Slimline
36 30W slimline (36") 48 38W slimline (48") 72 55W slimline (72") 96 75W slimline (96")
Accessories Order as separate catalog numbers.
SQ_ Swivel-stem hanger (specify length in 2" increments).
1B Ceiling spacer (adjusts from 1-1/2" to 2-1/2" from ceiling).
CONLGC 12" screw-on channel connector.
WGCUN Wireguard, 4' white.5
HC36 Chain hangers (1 pair, 36" long).
HRC Hooker® T-bar hanger (flush to ceiling).
HRC1 Hooker® T-bar hanger (1-1/2" from ceiling).
WGCSMR Wireguard, 4' white for symmetric reflector.5
WGCASR Wireguard, 4' white for asymmetric reflector.5
CSMR 48WH Symmetric reflector, 4' white, 7" aperture.5
CASR 48WH Asymmetric reflector, 4' white, 5-3/4" wide.5
Options
GEB Electronic ballasts, <20% THD3
GEB10IS Electronic ballasts, <10% THD instant start2
GEB10RS T8 electronic ballast, < 10% THD, rapid start
BILP IS, high efficiency, .78bf (low) 1/4 One four-lamp ballast4
EL Emergency battery pack (nominal 300 lumens)
GLR Internal fast-blow fuse (add X for external) GMF Internal slow-blow fuse (add X for external) PLF_ Plug-in wiring; specify 1, 2 or 3 branch circuits and hot wires (A = Black, B = Red, C = Blue, AB or AC)
TILW Tandem in-line wiring CW Cold-weather ballast; 0°F starting temp
CSA CSA Certified (only required for 347V) NOM NOM Certified
Sheet #: C STRP-100
C
For shortest lead times, configure product using standard options (shown in bold).
Example: C 2 32 MVOLT GEB10IS
ORDERING INFORMATION
C General-Purpose Strip
PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. All data based on 25°C. Full photometric data on these and other configurations available upon request.
Sheet #: C
Lithonia Lighting Fluorescent One Lithonia Way, Conyers, GA 30012 Phone: 770-922-9000, 800-315-4963, Fax: 770-602-1531 www.lithonia.com
MOUNTING DATA
For unit or row installation, surface or suspended mounting.
Unit installation — Minimum of two hangers required.
Row installation — Two hangers per channel required. One per fixture plus one per row if CONLGC installed.
Hooker® (HRC) and HC Hangers — Minimum two per channel
(unit and row) See ACCESSORIES below for hanging devices.
DIMENSIONS
Inches (millimeters). Subject to change without notice.
48", 72" and 96" have only two 7/8" K.O.'s 6" from each end 24" and 36" have only two 7/8" K.O.'s 3-1/4" from each end
D = 11/16 (17) Dia.K.O.
E = 7/8 (22) Dia.K.O.
F = 1-1/4 (32) Dia.K.O.
H = 2 (51) Dia.K.O.
Energy (Calculated in accordance with NEMA standard LE-5)
ANNUAL LAMP LAMP BALLAST
LER.FL ENERGY COST* DESCRIPTION LUMENS FACTOR WATTS
86.2 $2.79 (2)T8 F32 2900 .88 55
* Comparative yearly lighting energy cost per 1000 lumens
©1996 Acuity Brands Lighting, Inc., Rev. 4/16/09
Coefficients of Utilization %02fp pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
R C
R
Zonal Lumen Summary Zone Lumens % Lamp % Fixture
0° - 30° 0° - 40° 0° - 60° 0° - 90°
90° - 180° 0° - 180°
1785.8 3042.4 5944.0 9027.5 2341.8 11369.4
14.2 24.1 47.2 71.6 18.6 90.2
15.7 26.8 52.3 79.4 20.6 100.0
TEST NO: LTL 18310
C 2 96
LUMENS PER LAMP: 6300
Coefficients of Utilization
%02fp pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
R C
R
Zonal Lumen Summary Zone Lumens % Lamp % Fixture
0° - 30° 0° - 40° 0° - 60° 0° - 90°
90° - 180° 0° - 180°
842.1 1435.8 2810.1 4362.5 1021.0 5383.6
14.5 24.8 48.4 75.2 17.6 92.8
15.6 26.7 52.2 81.0 19.0 100.0
TEST NO: LTL 5181
C 2 32
LUMENS PER LAMP: 2900
Energy (Calculated in accordance with NEMA standard LE-5)
ORDERING ANNUAL LAMP LAMP BALLAST
INFORMATION LER.FL ENERGY COST* DESCRIPTION LUMENS FACTOR WATTS
C 2 32 MVOLT GEB10IS 77.6 $3.09 F32T8/735 2800 .88 59
C 2 32 MVOLT BILP 93.6 $2.56 F32T8/835/HT8 3100 .78 48
* Comparative yearly lighting energy cost per 1000 lumens
| Notes2: |
| Type2: |
| Catalog Number2: |
| 1: |
| 2: |
| 3: |
| 4: |
File details come from the government source that posted it. Updated .