TITLE SHEET

SWAN VALLEY RESTORATION

1 OF 23 T0.1

INDEX OF DRAWINGS

C-T NATIONAL FOREST PALISADES RANGER DISTRICT SWAN VALLEY,IDAHO

2 OF 23 S.1 SITE PLAN

4 OF 23 A1.1 BARN PLAN, WINDOWS, AND DOORS

PROJECT LOCATION

5 OF 23 A1.2 BARN ROOF PLAN, ELEVATIONS AND DETAILS

6 OF 23 A2.1 FIRE CACHE PLAN, WINDOWS AND DOORS

7 OF 23 A2.2

8 OF 23 A3.1

9 OF 23 A3.2

FIRE CACHE ROOF PLAN AND ELEVATION

3 OF 23 S.2 FENCE DETAILS

BUNKHOUSE ROOF PLAN AND ELEVATION

BUNKHOUSE ROOF PLAN AND ELEVATION

10 OF 23 A4.1

11 OF 23 A4.2

OFFICE ROOF PLAN AND ELEVATION

OFFICE ROOF PLAN AND ELEVATION

12 OF 23 A5.1

13 OF 23 A5.2

GARAGE ROOF PLAN AND ELEVATION

GARAGE ROOF PLAN AND ELEVATION

14 OF 23 A6.1

15 OF 23 A6.2

OILHOUSE ROOF PLAN AND ELEVATION

OILHOUSE ROOF PLAN AND ELEVATION

16 OF 23 A7.1

17 OF 23 A7.2

STORAGE ROOF PLAN WINDOWS AND DOORS

STORAGE ROOF PLAN AND ELEVATION

18 OF 23 A8.1

19 OF 23 A8.2

WINDOW AND DOOR DETAILS

WOOD FLAGPOLE DETAILS

20 OF 23 A8.3

21 OF 23 A8.4

SLIDING GARAGE DOOR DETAILS, SECTION, AND SCHEDULE

BUNKHOUSE STAIR DETAILS

22 OF 23 A8.5 OFFICE RAMP DETAILS

23 OF 23 A8.6 OFFICE PORCH DETAILS

SOILS AROUND SITE ARE LIKELY CONTAMINATED BY LEAD. REMOVE 3" OF

CONTAMINATED SOIL BEYOND A 10' PERIMETER OF 7 FACILITIES AFTER

TESTING AND CONSULTATION WITH EPA AND STATE AUTHORITIES.

PROVIDE NEW TOPSOIL AND REGRADE SITE TO DRAIN AWAY AT 4% SLOPE

FOR MINIMUM 10' BEYOND PERIMETER. DO NOT UNDERMINE CONCRETE

RAMPS INTO FACILITY. REGRADE SITE TO 20' BEYOND BUILDING

PERIMETERS. PROVIDE FS SPECIFIED SEED MIX TO STABILIZE AFTER

GRADING.

WELL

EXISTING HELIBASE

LEGEND

PAVED COUNTRY ROAD

BUILDINGS

OFFICE

BUNKHOUSE

DWELLING

BUNKHOUSE

SEED HOUSE

GARAGE/STORAGE

BARN

OIL HOUSE

FIRE CACHE/ SHOP 1339

1373 NIC- MODERN

1368 NIC- MODERN

1153 NIC MODERN

1122 NIC- ALREADY COMPLETED

HISTORICAL BOUNDARY

BUILDINGS

FENCES

UNDERGROUND POWER

OVERHEAD POWER

TRANSFORMER

TELEPHONE

WATER

WATER HYDRANT

SEWER

POWER POLE

SEWER LIFT STATION

STORAGE

RECREATION WAREHOUSE

BARN TO BE RESTORED

FIRE CACHE TO BE RESTORED

GAS/ OILHOUSE TO BE RESTORED

BUNKHOUSE TO BE RESTORED

OFFICE TO BE RESTORED

GARAGE/STORAGE BLDG TO BE RESTORED

STORAGE TO BE RESTORED

PROVIDE AND INSTALL NEW WOOD FLAGPOLE.

SEE SHEET A8.2

NEW BUCK AND POLE FENCE 10' BEYOND BLDG.

SCALE: 1/4" = 1'-0"

2' 4'0 8'

BUILDING #1329

BUILDING #1329 BUILDING #1329

BUILDING #1329

BUILDING #1329 BUILDING #1329 BUILDING #1329 BUILDING #1329

BUILDING #1329BUILDING #1329

BUILDING #1329

EDGE

NEW ICE AND WATER SHIELD

EXTEND 6' FROM ROOF

EXISTING WOOD RAFTERS

NEW ROOFTOP GUARD II OR EQUAL

NEW PLYWOOD SHEATHING

NEW FINISHED WOOD SHINGLES

12"

EXPOSED RAFTER TAILS,

MATCH EXISTING.

PAINTED

EXISTING SKIP SHEATHING

REPAINT EXISTING SIDING

NEW DRIP EDGE

NEW "CEDAR BREATHER" NYLON WAFFLE

DRAINAGE MATERIAL, OR EQUAL.

REPLACE DAMAGED WOOD SIDING TO MATCH EXISTING

REMOVE SOFFIT FROM FIRE CACHE

BUILDING #1329

BUILDING #1329 BUILDING #1329

BUILDING #1329 BUILDING #1329

2 X TRIM, MINIMAL TO SHOW TAIL

ALL WINDOW COMPONENTS AND TRIM SHALL BE REHABILITATED AS SPECIFIED IN SECTION 085920 ALL BROKEN GLASS AND ALL GLAZING IN WINDOWS SHALL BE REPLACED AS SPECIFIED IN SPEC SECTION 088000.

ALL HISTORIC DOORS SHALL BE REHABILITATED AS PER SPECIFICATION 085920. REPLACE ALL DOOR

HARDWARE.

ALL HISTORIC WINDOWS ARE FIXED WITH APPLIED TRIM. FIELD VERIFY ALL SIZES BEFORE UNDERTAKING WORK.

ALL HISTORIC DOORS ARE BUILT-UP UNITS WITH DECORATIVE APPLIED TRIM AS SHOWN ABOVE

LEAD BASED PAINT SHALL BE REMOVED FROM ALL SURFACES OF SIDING, DOORS AND WINDOWS AS PER 024130 AND 024134. REPAINT SIDING, DOORS AND WINDOWS TO MATCH EXISTING COLOR SCHEME

INVESTIGATE AND BID TO REPLACE ANY DAMAGED SIDING WITH IDENTICAL COMPONENTS.

THE CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING MODERN STEEL OVERHEAD DOOR

REMOVE EXISTING STEEL SIDING AND TRIM FROM THE ENTIRE FRONT OF THE FIRE CACHE.

ABATE LEAD BASED PAINT FROM ALL EXISTING WOOD SIDING, TRIM, WINDOWS AND DOORS.

THE CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING STEEL SWINGING DOOR

INVESTIGATE SIDING CONDITION W/ HISTORIC PRESERVATION CONSULTANT. REPLACE DAMAGED TRIM

REMOVE FRAME AND TRIM. PROVIDE NEW WOOD, RAISED FIVE PANEL DOOR TO MATCH HISTORIC CONFIGURATION, SEE SPECIFICATIONS/ HARDWARE LIST. REPLACE TRIM AND FRAME COMPONENTS IN KIND

PAINT ALL SIDING AND TRIM.

PROVIDE AND INSTALL NEW WOOD SLIDING GARAGE DOORS TO DUPLICATE HISTORIC CONFIGURATION DETAILS ARE SHOWN ON SHEET A.1.6. INSTALL NEW DOUBLE 2X 10 DOUG FIR NO 1 HEADERS OVER DOORS INSTALL NEW TRIM, POSTS AS SHOWN IN DETAILS ON SHEET A.1.6 WITH WOOD TRIM, SLIDING HARDWARE

PRIME/ PAINT WOOD COMPONENTS.

SCALE: 1/4" = 1'-0"

2' 4'0 8'

BUILDING #1339

BUILDING #1339

BUILDING #1339

BUILDING #1339 BUILDING #1339

AND SIDING IN KIND TO MATCH EXISTING PROFILES AND MATERIALS ON EXTERIOR OF THE FIRE CACHE.

ITEM & MODEL NUMBER

HARDWARE SCHEDULE

QUANTITYHRDWR GRP

MANUFACTURER

THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG

DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)

WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET

HINGES= 4-1/2"X4-1/2" BALL BEARING W/ FIXED PINS #BB1279NRP1 1/2 PAIR

1 EA.

1 EA.

1 EA.

1 EA.

1 EA.

PEMKO

PEMKO

PEMKO

SCHLAGE

HAGER

HAGER

LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION

FLOOR STOP= #245F

1 EA. SEE SHEET A8.3

Person door sliding door

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS

024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE FIRE CACHE, INCLUDING RAFTER

TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. THE CONTRACTOR MAY NEED TO

REMOVE FENCING ADJACENT TO BUILDING TO PERFORM WORK. REINSTALL ALL FENCING

AFTER COMPLETION.

BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN

SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE

SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION

SPECIALIST.

REMOVE AND REINSTALL EXISTING LIGHT FIXTURES AFTER ABATEMENT AND PAINTING.

REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER

SECTION 02413 AND DISPOSE OF THE WASTE AS PER SPEC 024134.

REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER

SPECIFICATION 073110.

INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT,

AND CEDAR BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.

INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN

SECTION 073111.

THE CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING STEEL SWINGING DOOR

REPLACE ALL DAMAGED TRIM AND SIDING TO MATCH EXISTING

REMOVE FRAME AND TRIM. PROVIDE NEW WOOD RAISED FIVE PANEL DOOR TO MATCH HISTORIC

CONFIGURATION, SEE SPECIFICATIONS/ HARDWARE LIST. REPLACE TRIM AND FRAME COMPONENTS IN KIND

PROFILES AND MATERIALS ON THE OTHER ELEVATIONS OF THE FIRE CACHE. PAINT SIDING AND TRIM.

REPLACE ANY DAMAGED TRIM AND SIDING TO MATCH EXISTING

PROFILES AND MATERIALS ON THE OTHER ELEVATIONS OF THE FIRE CACHE. PAINT SIDING AND TRIM.

PROVIDE AND INSTALL NEW WOOD SLIDING GARAGE DOORS TO DUPLICATE HISTORIC CONFIGURATION DETAILS ARE SHOWN ON SHEET A.8.3. INSTALL NEW DOUBLE 2X 10 DOUG FIR NO 1 HEADERS OVER DOORS INSTALL NEW TRIM, POSTS AS SHOWN IN DETAILS ON SHEET A.1.6 WITH SLIDING DOOR HARDWARE

PRIME/ PAINT WOOD COMPONENTS

REMOVE AND DISPOSE OF SOFFIT MATERIALS COVERING EXPOSED RAFTER TAILS. REPAIR/ CONSOLIDATE

WOOD TAILS AND TRIM. ABATE LEAD BASE PAINT, REPAINT.

BUILDING #1339

BUILDING #1339 BUILDING #1339

BUILDING #1339

BUILDING #1339

REMOVE ALL METAL SIDING AND TRIM FROM THIS ELEVATION

REMOVE EXISTING LIGHT FIXTURE REPLACE WITH DARK SKY KINGSTON OUTDOOR WALL SCONCE OR GOV.

APPROVED EQUAL. USE EXISTING ELECTRICAL BOX.

ABATE EXTERIOR LEAD PAINT AND REPAINT

NEW CUSTOM FIXED WOOD WINDOWS AND TRIM

SCALE: 1/4" = 1'-0"

2' 4'0 8'

CONTRACTOR TO PROVIDE AND INSTALL CUSTOM WOOD WINDOWS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE

GLASS, SET WITH GLAZING COMPOUND. WINDOWS SHALL BE PAINTED OUTSIDE AND IN.

REMOVE EXISTING WINDOW AND PREPARE OPENING FOR NEW CUSTOM WINDOW. FRAME AT BOTTOM

OF WINDOW TO CREATE UNIFORM HEIGHT FOR WINDOW OPENINGS, SEE ELEVATION.

CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD DOORS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. DOORS SHALL BE PAINTED OUTSIDE AND IN.

WINDOW TYPES 8 AND 9 SHALL BE OPERABLE SLIDING WINDOW TO ALLOW EMERGENCY EGRESS FROM

STRUCTURE WITH INSECT SCREEN. ADDITIONAL FRAMING, DRYWALL AND SHEATHING WILL BE

REQUIRED IN TYPE 9 WINDOWS TO REDUCE THE OPENING SIZE.

INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO MATCH ORIGINAL PROFILES.

INSTALL SURROUNDING WOOD TRIM AFTER CUTTING BACK OR PATCHING

SIDING WITH IN KIND MATERIALS. CAULK AROUND ALL PERIMETER.

CONSTRUCT NEW CONCRETE STAIR AND LANDING WITH HANDRAILS AT ENTRY TO BUNKHOUSE

SEE A8.4.

WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A3.2

HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED. REMOVE

INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND PREP OPENINGS FOR

REPLACEMENT.

ITEM & MODEL NUMBER

HARDWARE SCHEDULE

QUANTITYHRDWR GRP

MANUFACTURER

THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG

DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)

WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET

HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR

1 EA.

1 EA.

1 EA.

1 EA.

1 EA.

PEMKO

PEMKO

PEMKO

SCHLAGE

HAGER

HAGER

LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION

FLOOR STOP= #245F

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT

THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.

REMOVE ALL SIDING ON SOUTH ELEVATION AND REPLACE TO MATCH SIDING ON REMAINING WALL.

BACK PRIME AND PAINT NEW SIDING.

INSPECT CMU FOUNDATION, CLEAN AND INJECT CRACKS WITH TWO PART EPOXY CRACK REPAIR

SYSTEMS SUCH AS "WISE CHOICE" OR GOVERNMENT APPROVED EQUAL. CLEAN AND CUT BACK

AS RECOMMENDED BY MANUFACTURER. CREATE DOVETAIL SHAPE BEFORE REPAIRS, NOT V

SHAPE, WHICH CAN "PUSH OUT" REPAIR.

Typ

1 EA. ACORN MANUFACTURINGLATCHSET, HINGES, CLOSER KIT AZ1B1

WINDOWS 8 AND 9 SHALL HAVE REMOVABLE WOOD SCREENS CUSTOM CONSTRUCTED TO MATCH

HISTORICAL PROFILES. HOOKS EMBEDDED IN WINDOW FRAME OF NEW WINDOWS.

BUILDING #1106 NEW NEW

NEW

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE

BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, SOFFIT, FASCIA, ETC.

BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.

REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER SECTION 02413 AND

DISPOSE OF THE WASTE AS PER SPEC 024134.

REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER SPECIFICATION 073110.

INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT, AND CEDAR

BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.

INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN SECTION 073111.

BUILDING #1106

BUILDING #1106BUILDING #1106

EXISTING CONCRETE STEP TO BE DEMOLISHED AND REPLACED. SEE DETAILS ON SHEET A8.4

SCALE: 1/4" = 1'-0"

2' 4'0 8'

INSTALL SURROUNDING WOOD TRIM AFTER CUTTING BACK OR PATCHING SIDING WITH IN KIND MATERIALS. CAULK AROUND ALL PERIMETER.

HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED. REMOVE INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT. PROVIDE AND INSTALL NEW CUSTOM WOOD WINDOWS, DOORS, HARDWARE, AND TRIM AS SHOWN ON SHEET A3.1

REMOVE ANY DECORATIVE HISTORIC TRIM AND PROTECT FOR REINSTALLATION. PROVIDE AND INSTALL NEW 1

2" OSB OR PLYWOOD SKIP SHEATHING

OVER EXISTING SKIP SHEATHING.

PROVIDE AND INSTALL 3' OF ICE AND WATER SHIELD. COVER WITH 30# ASPHALT IMPREGNATED FELT. INSTALL "CEDAR BREATHER" MESH OVER ENTIRE ROOF. PROVIDE INSTALL CEDAR #1 PERFECT CEDAR SHINGLES W/ 5" EXPOSURE, STAINED AS DESCRIBED IN SPECIFICATIONS.

INVESTIGATE AND REHAB WOOD GRILL. CONSOLIDATE/ EPOXY SALVAGEABLE WOOD COMPONENTS. INSTALL INSECT SCREEN AT REAR. REPLACE ANY

ROTTED COMPONENTS IN KIND. REPAINT AND REINSTALL REHABILITATED LOUVERED VENT.

REMOVE ALL SIDING ON SOUTH ELEVATION AND REPLACE TO MATCH SIDING ON REMAINING WALLS. BACK PRIME AND PAINT NEW SIDING.

BUILDING #1106

REPAIR WOOD AT RAKE BOARD BY CONSOLIDATING/ PATCHING EXISTING COMPONENT. PAINT AND REINSTALL.

INSPECT CMU FOUNDATION, CLEAN AND INJECT CRACKS WITH TWO PART EPOXY CRACK REPAIR SYSTEMS SUCH AS "WISE CHOICE" OR GOVERNMENT APPROVED EQUAL. CLEAN AND CUT BACK AS RECOMMENDED BY MANUFACTURER. CREATE DOVETAIL SHAPE BEFORE REPAIRS, NOT V SHAPE, WHICH CAN "PUSH OUT" REPAIR.

PROVIDE AND INSTALL NEW "TEMP VENT" FOUNDATION VENTS OR GOVERNMENT APPROVED EQUAL. AUTOMATIC VENTS CLOSE WHEN TEMPERATURE GET BELOW 38 DEGREES. INSTALL IN EXISTING CONCRETE BLOCK WALL. PROVIDE TRIM AND FOAM INSULATION TO FORM A

RODENT PROOF ASSEMBLY.

BUILDING #1106

BUILDING #1106

5 EA NEW CUSTOM SINGLE HUNG

ABATE EXTERIOR LEAD PAINT AND REPAINT

BUILDING # 1203

BUILDING # 1203

BUILDING # 1203

WOOD WINDOW AND TRIM

CONTRACTOR TO PROVIDE AND INSTALL CUSTOM WOOD WINDOWS IN PROFILES SHOWN ABOVE.

MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. PROVIDE

TRUE MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. WINDOWS SHALL BE

PAINTED OUTSIDE AND IN.

CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD DOORS IN PROFILES SHOWN ABOVE.

MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE

MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. DOORS SHALL BE PAINTED

OUTSIDE AND IN.

INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO

MATCH ORIGINAL PROFILES.

ITEM & MODEL NUMBER

HARDWARE SCHEDULE

QUANTITYHRDWR GRP

MANUFACTURER

THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG

DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)

WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET

HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR

1 EA.

1 EA.

1 EA.

1 EA.

1 EA.

PEMKO

PEMKO

PEMKO

SCHLAGE

HAGER

HAGER

LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION

FLOOR STOP= #245F

1 EA. LATCHSET, HINGES, CLOSER KIT = AZ1BI . ACORN MNFCTRNG

1 EA NEW CUSTOM SINGLE HUNG

WOOD WINDOW AND TRIM

THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG

DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)

WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET

HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP3 PAIR

1 EA.

1 EA.

1 EA.

1 EA.

2 EA.

LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION

FLOOR STOP= #245F

INSTALL NEW WOOD WINDOWS AND SURROUNDING WOOD TRIM. CAULK AROUND ALL PERIMETER.

DEMOLISH AND DISPOSE OF EXISTING CONCRETE PORCH. SHORE COLUMNS. CONSTRUCT NEW

WOOD FRAMED PORCH AT ENTRY TO OFFICE. SEE DETAILS ON A8.6.

WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A4.2

HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. (MUNTINS HAVE BEEN REMOVED) REMOVE AND DISPOSE OF INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND

PREP OPENINGS FOR REPLACEMENT.

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.

BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE

FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.

PROVIDE AND INSTALL NEW REPLICA OF HISTORIC WOOD DOOR(S) AND FRAMING. SEE DOOR

SCHEDULE FOR DETAILS AND HARDWARE SCHEDULE.

DEMOLISH AND DISPOSE OF EXISTING CONCRETE STOOP. CONSTRUCT NEW WOOD FRAMED ADA

RAMP AND HANDRAILS AS SHOWN IN DETAILS ON SHEET A8.5

PROVIDE AND INSTALL NEW REMOVABLE WOOD SCREENS AND

STORM WINDOWS TO MATCH HISTORICAL PROFILES, WOOD WITH

HOOKS AT NEW WOOD WINDOW FRAME.

PEMKO

PEMKO

PEMKO

SCHLAGE

HAGER

HAGER

REMOVABLE STORM WINDOW REMOVABLE INSECT SCREEN

REMOVABLE STORM WINDOW REMOVABLE INSECT SCREEN

BUILDING # 1203

BUILDING # 1203BUILDING # 1203

BUILDING # 1203

ABATE EXTERIOR LEAD PAINT AND REPAINT

BUILDING # 1203

REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD

BASED PAINT AS PER SECTION 02413 AND DISPOSE OF

THE WASTE AS PER SPEC 024134.

REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM

AS PER SPECIFICATION 073110.

INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD,

UNDERLAYMENT, AND CEDAR BREATHER OVER SKIP SHEATHING.

SPECIFICATION 073110.

INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH

FINISH SPECIFIED IN SECTION 073111.

ROOF NOTES

KEYED NOTES

INSTALL NEW WOOD WINDOWS AND SURROUNDING WOOD TRIM AFTER CUTTING BACK OR PATCHING

SIDING WITH IN KIND MATERIALS. CAULK AROUND ALL PERIMETER.

DEMOLISH AND DISPOSE OF EXISTING CONCRETE PORCH. SHORE COLUMNS. CONSTRUCT NEW

WOOD FRAMED PORCH AT ENTRY TO OFFICE. SEE DETAILS ON A8.6.

WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A4.2

HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. (MUNTINS HAVE BEEN REMOVED) REMOVE AND DISPOSE OF INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND

PREP OPENINGS FOR REPLACEMENT.

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.

BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE

FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.

PROVIDE AND INSTALL NEW REPLICA OF HISTORIC WOOD DOOR(S) AND FRAMING. SEE DOOR

SCHEDULE FOR DETAILS AND HARDWARE SCHEDULE.

DEMOLISH AND DISPOSE OF EXISTING CONCRETE STOOP. CONSTRUCT NEW WOOD FRAMED ADA

RAMP AND HANDRAILS AS SHOWN IN DETAILS ON SHEET A8.5

INSPECT AND RESTORE EXISTING WOOD LOUVERED GRILL. EPOXY EXISTING COMPONENTS.

INSTALL INSECT SCREEN AT REAR AND REINSTALL.

REMOVE AND INSTALL NEW LIGHT IN EXISTING ELECTRICAL BOX. PROVIDE DARK SKY KINGSTON

OUTDOOR WALL SCONCE BY WORLD IMPORTS OR GOVERNMENT APPROVED EQUAL.

BUILDING #1327

LEAD BASED PAINT SHALL BE REMOVED FROM ALL SURFACES OF DOORS AND WINDOWS AS PER 024130

AND 024134. REPAINT DOORS/ WINDOWS TO MATCH EXISTING COLOR SCHEME

ABATE LEAD BASED PAINT

ABATE LEAD BASED PAINT REHAB DOOR CONSTRUCT WOOD DOOR REPLICA

ABATE EXTERIOR LEAD PAINT AND REPAINT

ITEM & MODEL NUMBER

HARDWARE SCHEDULE

QUANTITYHRDWR GRP

MANUFACTURER

THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG

DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)

WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET

HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR

1 EA.

1 EA.

1 EA.

1 EA.

1 EA.

PEMKO

PEMKO

PEMKO

SCHLAGE

HAGER

HAGER

LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION

FLOOR STOP= #245F

WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL

REPAIR. SEE SHEET A5.2

REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST.

ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW

INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS

INSIDE AND OUT. CONSTRUCT NEW WOOD WINDOW SCREENS AND STORM WINDOWS FOR

SLIDING WINDOWS AS SHOWN HERE.

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS

024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER

TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A

PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM

TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE

FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.

REMOVE PLYWOOD SURROUNDING DOOR. REFRAME 2 X 4 WALL, VERIFY AND FRAME

2'-8" X 6'-8" DOOR OPENING AND INSTALL NEW EXTERIOR GRADE 1

2" OSB SHEATHING.

WALL SHALL CONSTRUCTED TO ALLOW FLUSH INSTALLATION OF NEW SIDING TO MATCH

EXISTING SIDING. INSTALL FLUSH TRIM AROUND OPENING, INSTALL NEW DOOR.

CONSTRUCT WOOD DOOR REPLICA

CONTRACTOR TO REHABILITATE WOOD WINDOWS IN PROFILES SHOWN ABOVE AS PER SECTION 085920. MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. ALL BROKEN GLASS AND ALL GLAZING IN WINDOWS SHALL BE REPLACED AS SPECIFIED IN SPEC SECTION 088000 WINDOWS SHALL BE PAINTED

OUTSIDE AND IN.

CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD PERSONNEL DOORS IN PROFILES SHOWN ABOVE.

MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. DOORS SHALL BE PAINTED

OUTSIDE AND IN.

WINDOW TYPE 12 REQUIRES CONSTRUCTION OF NEW REMOVABLE WOOD SCREENS AND WOOD

STORM WINDOWS. INSTALL HOOKS ON EXISTING WINDOW FRAMES TO SUPPORT. PAINT ALL WOOD

COMPONENTS.

REHABILITATE OR INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO MATCH ORIGINAL

PROFILES.

& REHAB WINDOW

ABATE LEAD BASED PAINT

& REHAB WINDOW

HISTORIC PERSONNEL DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. REMOVE AND

DISPOSE OF INAPPROPRIATE DOORS AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT.

INSPECT AND REPAIR TRIM, OR INSTALL NEW TRIM IN KIND TO MATCH HISTORIC PROFILES. PROVIDE AND INSTALL NEW HISTORIC WOOD DOOR REPLICAS. PAINT ALL WOOD COMPONENTS INSIDE AND OUT.

PROVIDE NEW HARDWARE.

REHAB HISTORIC DOOR AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST.

ABATE LEAD BASED PAINT, INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF

EPOXY. REPAINT DOOR INSIDE AND OUT. REMOVE HARDWARE, CLEAN, AND REINSTALL.

REPLACE ANY NON-FUNCTIONAL HARDWARE IN KIND.

CONTRACTOR TO REHABILITATE LARGE WOOD SWINGING DOOR IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOOR IN KIND.CONSOLIDATE DAMAGED WOOD COMPONENTS OR REPLACE IN KIND AFTER CONSULTING W/ HISTORIC PRESERVATION SPECIALIST. DOOR SHALL BE PAINTED OUTSIDE AND IN.

2 EA

BUILDING #1327

BUILDING #1327BUILDING #1327

BUILDING #1327

REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER SECTION 02413 AND

DISPOSE OF THE WASTE AS PER SPEC 024134.

REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER SPECIFICATION 073110.

INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT, AND CEDAR

BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.

INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN SECTION 073111.

BUILDING #1106

WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A5.2

REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS INSIDE AND OUT. CONSTRUCT NEW WOOD WINDOW SCREENS AND STORM

WINDOWS FOR SLIDING WINDOWS.

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH

HISTORIC PRESERVATION SPECIALIST.

REMOVE PLYWOOD SURROUNDING DOOR. REFRAME 2 X 4 WALL, VERIFY AND FRAME 2'-8" X 6'-8" DOOR OPENING AND

INSTALL NEW EXTERIOR GRADE 1

2" OSB SHEATHING. WALL SHALL CONSTRUCTED TO ALLOW FLUSH INSTALLATION OF NEW

SIDING TO MATCH EXISTING SIDING. INSTALL FLUSH TRIM AROUND OPENING, INSTALL NEW DOOR.

HISTORIC PERSONNEL DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. REMOVE AND DISPOSE OF INAPPROPRIATE DOORS AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT. INSPECT AND REPAIR TRIM, OR INSTALL NEW TRIM IN KIND TO MATCH HISTORIC PROFILES. PROVIDE AND INSTALL NEW HISTORIC WOOD DOOR REPLICAS. PAINT

ALL WOOD COMPONENTS INSIDE AND OUT. PROVIDE AND INSTALL NEW HARDWARE.

REHAB HISTORIC DOOR AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT DOOR INSIDE AND OUT. REMOVE

HARDWARE, CLEAN, AND REINSTALL. REPLACE ANY NON-FUNCTIONAL HARDWARE IN KIND.

WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A6.2

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.

BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE

FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.

ABATE EXTERIOR LEAD PAINT AND REPAINT

REMOVE EXISTING CONCRETE APRON. PROVIDE AND INSTALL 4" THICK CONCRETE PAD WITH 6" OF

GRAVEL FILL UNDER SLAB.

REPAIR WOOD OVERHEAD DOOR. CONSOLIDATE WOOD PARTS, REPLACE ROTTED COMPONENTS IN

KIND AS DESCRIBED IN SECTION 085920. ABATE LEAD BASED PAINT. REPAINT INTERIOR AND EXTERIOR. REPAIR WOOD TRIM AND REPAINT. INSPECT DOOR HARDWARE. REPLACE HASP, AND DOOR

PULL, CLEAN INTERIOR TRACK.

ABATE EXTERIOR LEAD PAINT AND REPAINT

2 EACH

ABATE EXTERIOR LEAD PAINT AND REPAINT

1 EACH

ALL WINDOW COMPONENTS AND TRIM SHALL BE REHABILITATED AS SPECIFIED IN SECTION 085920 ALL BROKEN GLASS AND ALL GLAZING IN WINDOWS SHALL BE REPLACED AS SPECIFIED IN SPEC SECTION 088000.

HISTORIC DOOR SHALL BE REHABILITATED AS PER SPECIFICATION 085920. REMOVE FUNCTIONAL ALL DOOR HARDWARE AND REMOVE PAINT. REINSTALL FUNCTIONAL HARDWARE AFTER DOOR REPAIR. REPLACE HARDWARE NOTED ABOVE

ALL HISTORIC WINDOWS ARE FIXED WITH APPLIED TRIM

ALL HISTORIC DOORS ARE BUILT-UP UNITS WITH DECORATIVE APPLIED TRIM AS SHOWN ABOVE

LEAD BASED PAINT SHALL BE REMOVED FROM ALL SURFACES OF DOORS AND WINDOWS AS PER 024130 AND 024134.

REPAINT DOORS/ WINDOWS TO MATCH EXISTING COLOR SCHEME

INVESTIGATE AND BID TO REPLACE ANY DAMAGED SIDING WITH IDENTICAL COMPONENTS

ITEM & MODEL NUMBER

HARDWARE SCHEDULE

QUANTITYHRDWR GRP MANUFACTURER

1 1 EA. AMERICAN LOCKHEAVY DUTY CENTERED HOLE HASP A535

1 EA. YALEREMOVABLE CORE PADLOCK, MODEL #424

1 EA. BALDWIN 4" x 1 1/8" BRONZE SASH PULL MODEL #470

REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER SECTION 02413 AND

DISPOSE OF THE WASTE AS PER SPEC 024134.

REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER SPECIFICATION 073110.

INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT, AND CEDAR

BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.

INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN SECTION 073111.

BUILDING #1330

BUILDING #1330

SCALE: 1/4" = 1'-0"

2' 4'0 8'

BUILDING #1330

BUILDING #1330 BUILDING #1330

WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE INFORMATION ADJACENT.REMOVE

AND REINSTALL EXISTING EXHAUST FAN AFTER ROOF INSTALLATION

REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS INSIDE AND OUT. CONSTRUCT NEW WOOD WINDOW SCREENS AND STORM

WINDOWS FOR SLIDING WINDOWS.

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH

HISTORIC PRESERVATION SPECIALIST.

REHAB HISTORIC DOOR AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT DOOR INSIDE AND OUT. REMOVE

HARDWARE, CLEAN, AND REINSTALL. REPLACE HARDWARE AS NOTED ON SHEET A6.1.

HARDWARE SCHEDULE

QUANTITYHRDWR GRP

MANUFACTURER

THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG

DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)

WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET

HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR

1 EA.

1 EA.

1 EA.

1 EA.

1 EA.

PEMKO

PEMKO

PEMKO

SCHLAGE

HAGER

HAGER

LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION

FLOOR STOP= #245F

BUILDING #1328

SCALE: 1/4" = 1'-0"

2' 4'0 8'

ABATE EXTERIOR LEAD PAINT AND REPAINT

NOTES

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.

BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST. THIS FACILITY HAS BEEN

BADLY DAMAGED BY LIVESTOCK. EVALUATE AND REPLACE MISSING COMPONENTS WITH IN KIND

MATERIALS.

METAL ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A7.2

REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST.

ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW

INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS

INSIDE AND OUT.

HISTORIC PERSONNEL DOOR HAS BEEN DESTROYED BY LIVESTOCK. REMOVE AND DISPOSE OF DOOR AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT. INSPECT AND REPAIR TRIM, OR INSTALL NEW TRIM IN KIND TO MATCH HISTORIC PROFILES. PROVIDE AND INSTALL NEW HISTORIC WOOD DOOR

REPLICA. PAINT ALL WOOD COMPONENTS INSIDE AND OUT. PROVIDE NEW HARDWARE.

NEW NEW

NEW

CONTRACTOR TO PROVIDE AND INSTALL CUSTOM WOOD WINDOWS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE

GLASS, SET WITH GLAZING COMPOUND. WINDOWS SHALL BE PAINTED OUTSIDE AND IN.

CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD DOORS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. DOORS SHALL BE PAINTED OUTSIDE AND IN.

INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO MATCH ORIGINAL PROFILES.

ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY.

EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.

BUILDING #1328

BUILDING #1328

BUILDING #1328BUILDING #1328

REMOVE EXISTING METAL ROOFING.

REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER

SPECIFICATION 073110.

INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD,

UNDERLAYMENT, AND CEDAR BREATHER OVER SKIP SHEATHING.

SPECIFICATION 073110.

INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH

SPECIFIED IN SECTION 073111.

REMOVE EXISTING DOOR AND THRESHOLD. REPLACE WOOD DOOR IN KIND, PAINT AND PROVIDE NEW DOOR HARDWARE. INSPECT WOOD FRAME

AND REPLACE ANY ROTTED COMPONENTS IN KIND.

REMOVE AND REPLACE WOOD WINDOWS IN KIND. REPLACE MISSING WOOD SILLS . PAINT WINDOWS INSIDE AND OUT.

REMOVE AND DISPOSE OF EXISTING CORRUGATED ROOFING. INSTALL SHEATHING, UNDERLAYMENT AND WOOD SHINGLES. SEE DESCRIPTION ON

THIS SHEET.

REPLACE CORNER TRIM DESTROYED BY HORSES WITH IN KIND PRODUCT.

PROVIDE AND INSTALL NEW WOOD POLE FENCE AT 10' BEYOND FACILITY PERIMETER. SEE DETAILS FOR FENCE CONTRACTION AND GATE DETAILS.

TIE INTO EXISTING FENCE AS DIRECTED BY THE COR.

SCALE: 1/4" = 1'-0"

2' 4'0 8'

BUILDING #1328

WOODEN FLAGPOLE FABRICATED FROM

TAPERED TRUE LODGEPOLE PINE, TREATED AND

PAINTED WHITE.

8" BRASS BALL AT FLAGPOLE TERMINATION W/

HOLE DRILLED AT TOP AND BOTTOM. LAG

SCREW THE BALL TO THE TERMINATION.

APPROXIMATELY 41

2" DIA AT TOP OF POLE.

4" X 1" METAL BAND WITH PULLEY FOR ROPE

ATTACHMENT.

ROPE W/ SNAP HOOK TO ATTACH FLAG.

ROPE TIE AT BASE

APPROXIMATELY 10" DIA AT BASE

2 EACH APPROXIMATELY 8" DIA TREATED,

PAINTED STUBS, EXTENDED 6' BELOW GRADE.

LAG BOLT W/ 3

4" x 26" GALVANIZED LAGS, W/

NUTS/ WASHERS.

6'-6" X 3'-3" CONCRETE BASE

DOOR 07

DOOR 07

A8.3

GARAGE DOOR & COLUMN DETAILS

HARDWARE SCHEDULE/DESCRIPTION:

4-EACH.H-01

ITEM QUANTITY LOCATION DESCRIPTION:

GARAGE DOOR

HEAD.

12-EACH.H-02 BRACKET, OVERHEAD DOUBLE CENTER=ITEM #0031.00069 AS MANUFACTURED BY:

RICHARDS-WILCOX CO., AURORA. IL. OR AN APPROVED EQUAL.

2-EACH.

10' LONG.

H-04

TRACK=ITEM #0031.00115/ 0031.00117 AS MANUFACTURED BY:

RICHARDS-WILCOX CO., AURORA, IL. OR AN APPROVED EQUAL.

GARAGE DOOR

HEAD.

GARAGE DOOR

HEAD.

2-EACH.H-05 DOOR LATCH ASSEMBLY=ITEM #0152.00023 WITH PADLOCKS AS MANUFACTURED BY:

RICHARDS-WILCOX CO., AURORA, IL. OR AN APPROVED EQUAL.

GARAGE DOOR

JAMB.

2 EA-PAIR

(RIGHT/LEFT)H-06 POST CAPS= MODEL #LPC6 AS MANUFACTURED BY:

SIMPSON STRONG-TIE CO., OR AN APPROVED EQUAL.

TOP OF NEW

POST.

3-EACH.H-07 POST BASE= MODEL #ABU46, STAND OFF POST, AS MANUFACTURED BY:

SIMPSON STRONG-TIE CO., OR AN APPROVED EQUAL.

BTM. OF NEW

POSTS.

EXISTING CONCRETE

FLOOR.

NEW 2 X FILLER.

NEW 4" X 6"

POST.

NEW TRIM.

A

PP

R O

X

NEW TRIM.

NEW 1 X TRIM.

NEW METAL

COLUMN CAP.

(SEE SCHEDULE

THIS SHEET).

NEW 1 X FIR FRIEZE.

NEW TRIM.

(2)-2" X 10"

DOUG FIR NO 1HEADER.

NEW METAL

COLUMN BASE.

(SEE SCHEDULE

THIS SHEET).

H-06

H-07

H-07

MANUFACTURERS NAMES AND MODEL NUMBERS ARE GIVEN TO ESTABLISH A REQUIRED FUNCTION AND ACCEPTABLE QUALITY. PRODUCTS OF OTHER MANUFACTURERS MAY BE SUBMITTED FOR REVIEW AND APPROVAL.

H-03

GARAGE DOOR

HEAD.

TRUCK/ HANGER ASSEMBLY=ITEM #3110 AS MANUFACTURED BY:

RICHARDS-WILCOX CO., AURORA. IL. OR AN APPROVED EQUAL.

3 EACH 2 X 4 COLUMN

H-01

4 EACH "END BLINDS"

H-02

12 EACH "DOUBLE CENTER"

0031.00050 RICHARDS-WILCOX

0031.00069 RICHARDS-WILCOX

1 EACH "DOUBLE LOCK JOINT"2 EACH DOOR LATCH W/

H-03

22 LF OF RICHARDS-WILCOX 31 TRACK

H-04

RICHARDS-WILCOX 3100 TRUCK/ HANGER

ASSEMBLY 8 TOTAL, EVENLY SPACED, 2 DOORS

BOLT AS RECOMMENDED BY MANUFACTURER

1 X 8 CLEAR VERTICAL GRAIN DOUGLAS FIR

TRIM EDGE W/ QUARTERROUND

PRIME AND PAINT COMPONENTS

1 X 4 OR 6 CLEAR VERTICAL GRAIN DOUGLAS FIR

TONGUE AND GROOVE FLOORING, Vertically ORIENTED

PRIME AND PAINT COMPONENTS

A8.3

A8.3

BEYOND

1 X 8 CLEAR VERTICAL GRAIN DOUGLAS FIR

TRIM EDGE W/ QUARTERROUND

PRIME AND PAINT COMPONENTS

1 X 4 OR 6 CLEAR VERTICAL GRAIN DOUGLAS FIR

TONGUE AND GROOVE FLOORING, Vertically ORIENTED

PRIME AND PAINT COMPONENTS

1 X 12 CLEAR VERTICAL GRAIN

TRIM EDGE W/ QUARTERROUND

PRIME AND PAINT COMPONENTS

DOUGLAS FIRDUPLICATE ORIGINAL

NEW METAL

COLUMN BASE.

(SEE SCHEDULE

THIS SHEET).

POWER COATED

END BIND=ITEM #0376.00087 AS MANUFACTURED BY:

RICHARDS-WILCOX CO., AURORA. IL. OR AN APPROVED EQUAL.

4-EACH.

6' LONG.

8-EACH.

H-05

HASPS/ PADLOCK AT

OUTSIDE JAMBS

DETAIL AT COLUMN BASE/DOOR BOTTOM

SCALE: 3"= 1'-0"

SCALE: 3" = 1'-0"

2" 4"0 8"

PLAN VIEW COLUMN AND DOORS

SCALE: 3"= 1'-0"

SECTION THRU DOOR HEADER

SCALE: 3"= 1'-0"

ENGINEERED FILL

CONCRETE STAIRS WITH 11" TREADS, METAL NOSING

#4 BAR@ 12" OC, BOTH DIRECTIONS

CONCRETE FOOTING UNDER POST

12" X 12" W/ 4 EACH #4 HORIZONTAL

AND 3 EACH #4 VERTICAL UNDER RAIL POST

2 EA #4 BAR

4" THICK SLAB #4 12" OC BOTH DIRECTIONS

WOOD GUARD RAIL SEE 2/A8.4

2 X 2 REDWOOD BALUSTRADES

PAINTED SECURE END POST TO EXISTING WALL.

4 X 4 REDWOOD POSTS

4 X 4 PAINTED REDWOOD POSTS

SIMPSON STRONG TIE PB44- ZMAX

12" x 12" CONCRETE FOOTING

2 X 4 PAINTED REDWOOD RAIL

2 X 2 PAINTED WOOD BALUSTRADE

REINFORCE WITH 3 EA #4 HORIZONTAL

4 EA #4 VERTICAL

2 X 4 PAINTED REDWOOD RAIL

CONNECT W/ SIMPSON LSU24

2 X 6 SHAPED REDWOOD TOP RAIL,

PAINTED, SECURED TO POST W/ NAILS

2 X 4 PAINTED SHAPED REDWOOD RAIL

CONNECT W/ SIMPSON LSU24

STAIR BEYOND

LOCATE TO ALIGN W RAIL AT DECKING

CONSTRUCT RAIL RETURN W/ THIS COMPONENT

CUSTOM PAINTED STEEL BRACKET 8" X 8" X 1/4"

WELDED TO 4"X 4" X1/4" X 6" STEEL TUBE

4 EA 1/2" X 4" EXPANSION ANCHORS

LAG TO POST AT TUBING

CUSTOM PAINTED STEEL BRACKET 8" X 8" X 1/4"

WELDED TO 4"X 4" X1/4" X 6" STEEL TUBE

4 EA 1/2" X 2 5/8" REDHEAD EXPANSION ANCHORS

LAG TO POST AT TUBING

8" CONCRETE FOUNDATION WALL

REINFORCED W/ # 4 REBAR EVERY 18"

BOTH DIRECTIONS

8" CONCRETE FOUNDATION WALL REINFORCED W/ # 4 REBAR

EVERY 18" BOTH DIRECTIONS

CONCRETE ACCESSIBLE RAMP 1:12 SLOPE W/ REDWOOD

POSTS, BALUSTRADES AND DECORATIVE RAILING.

5' X 5' X 4" THICK CONCRETE PAD AT BASE OF RAMP.

5' X 5' X 4" THICK CONCRETE PAD AT

BASE OF RAMP. TIE TO EXISTING

SIDEWALK.

ENGINEERED FILL

CONCRETE ACCESSIBLE RAMP 1:12 SLOPE

W/ REDWOOD POSTS, BALUSTRADES AND

DECORATIVE RAILING.

18" X 18" #4 REBAR TO TIE WALL TO

SLAB

STEM WALL TO 30" BELOW GRADE

LINE OF FINISHED FLOOR, EXISTING

BUILDING. REMOVE SIDING AT

CONCRETE WALL AND LINE FRAMED

WALL WITH ICE AND WATER SHIELD

BEFORE POURING FOUNDATION

WALL.

4 X 4 REDWOOD POSTS, PAINTED

BUILT UP REDWOOD RAILING,

PAINTED .

PAINTED STEEL BRACKETS W/

EXPANSION ANCHORS INTO

CONCRETE.

FILL IN INTERSTITIAL SPACE W/ WEED MAT AND 4" OF

GRAVEL UPON COMPLETION.

LINE OF EXTERIOR WALL, HISTORIC OFFICE.

PAINTED STEEL BRACKETS W/ EXPANSION ANCHORS

INTO CONCRETE. FLAT AND SLOPED

CONFIGURATION, SEE DETAILS ADJACENT.

4" X 4" X 1

4" STEEL TUBE, 4" TALL, PREDRILLED FOR 2 EACH

LAG CONNECTION TO POSTS.

4" STEEL PLATE, FILLET WELDED TO TUBE, 4 EA

PREDRILLED FOR 4 EACH 3

8" "TRUBOLT" EXPANSION

ANCHORS.

8" X 25

8" WEDGE ANCHORS BY "REDHEAD" OR EQUAL.

15 EACH FLAT

CONNECTORS FOR RAMP

4 EACH SLOPED

CONNECTORS FOR RAMP

BUILT UP REDWOOD RAILING,

PAINTED .

12" RAILING RETURN

FRAMED W SHAPED

REDWOOD, PAINTED.

BUILDING # 1203

8" CONCRETE FOUNDATION

#4 REBAR 18" OC BOTH DIRECTIONS

2 X 6 REDWOOD DECKING

FOR STAIRS, RISERS AND PORCH

ROUND PROFILE AS SHOWN

TREATED WOOD 2 X'S

STRINGERS AND HORSES 4' OC

TREATED WOOD 2 X 8 FOR

LEDGER, ANCHOR W/ 1/2"

16"

EQ

EQ

EQ

12"

12"

4 X 4 X 1/4" ANGLE

WITH LAG TO HORSE

1/2" ANCHOR BOLT TO CONCRETE

CONTINUOUS CONCRETE FOOTING

99'-1 1/2"

TOP OF WALL

FILL UNDER PORCH

6'-0"

EXISTING CONCRETE FOUNDATION WALL

FINISHED FLOOR AT 100'

PAINTED 1 X 6 TRIM

EXISTING EXTERIOR WALL

AFTER CUTTING BACK FOR PORCH

REPAINT EXISTING SIDING

REPLACE SIDING AS NEEDED

2 X 10 LEDGER SECURE W/

8"

16"

X 3 3/8" EXPANSION ANCHOR

AT 32" OC

REPLACE OR CONSOLIDATE

DAMAGED COMPONENTS

EXISTING COLUMN, LOWER INTO PLACE

2 x 10 DOUG FIR NO 2

16" OC AND UNDER COLUMN

3/8" LAG BOLT 18" OC

2 ea #4 REBAR LONGITUDINALLY AND

CONTINUOUS CONCRETE FOOTING

#4 18" OC TRANSVERSELY

#4 18" OC TRANSVERSELY

2 x 10 DOUG FIR NO 2

16" OC AND UNDER COLUMN

TREATED WOOD 2 X'S

STRINGERS AND HORSES 4' OC

COLUMN ABOVE

2 X 6 REDWOOD DECKING

FOR STAIRS, RISERS AND PORCH

ROUND PROFILE AS SHOWN

TREATED WOOD 2 X 8 FOR

SILL, ANCHOR W/ 1/2"

X 6" EXPANSION ANCHOR

AT 32" OC

2 X 10 LEDGER SECURE W/

3/8" LAG BOLT 18" OC

2 EA 2 x 10 DOUG FIR NO 2

HUNG W SIMPSON HU410

HUNG W SIMPSON HU210'S

REPLACE OR CONSOLIDATE

EXISTING COLUMN, LOWER INTO PLACE

COVED TRIM

2 X REDWOOD, PAINTED

COVED TRIM

2 EA 2 x 10 DOUG FIR NO 2

HUNG W SIMPSON HU410

8" CONCRETE FOUNDATION

#4 REBAR 18" OC BOTH DIRECTIONS

1/2" ANCHOR BOLT TO CONCRETE

T-1
S.1
S.2
A1.1
A1.2
A2.1
A2.2
A3.1
A3.2
A4.1
A4.2
A5.1
A5.2
A6.1
A6.2
A7.1
A7.2
A8.1
A8.2
A8.3
A8.4
A8.5
A8.6