TITLE SHEET
SWAN VALLEY RESTORATION
1 OF 23 T0.1
INDEX OF DRAWINGS
C-T NATIONAL FOREST PALISADES RANGER DISTRICT SWAN VALLEY,IDAHO
2 OF 23 S.1 SITE PLAN
4 OF 23 A1.1 BARN PLAN, WINDOWS, AND DOORS
PROJECT LOCATION
5 OF 23 A1.2 BARN ROOF PLAN, ELEVATIONS AND DETAILS
6 OF 23 A2.1 FIRE CACHE PLAN, WINDOWS AND DOORS
7 OF 23 A2.2
8 OF 23 A3.1
9 OF 23 A3.2
FIRE CACHE ROOF PLAN AND ELEVATION
3 OF 23 S.2 FENCE DETAILS
BUNKHOUSE ROOF PLAN AND ELEVATION
BUNKHOUSE ROOF PLAN AND ELEVATION
10 OF 23 A4.1
11 OF 23 A4.2
OFFICE ROOF PLAN AND ELEVATION
OFFICE ROOF PLAN AND ELEVATION
12 OF 23 A5.1
13 OF 23 A5.2
GARAGE ROOF PLAN AND ELEVATION
GARAGE ROOF PLAN AND ELEVATION
14 OF 23 A6.1
15 OF 23 A6.2
OILHOUSE ROOF PLAN AND ELEVATION
OILHOUSE ROOF PLAN AND ELEVATION
16 OF 23 A7.1
17 OF 23 A7.2
STORAGE ROOF PLAN WINDOWS AND DOORS
STORAGE ROOF PLAN AND ELEVATION
18 OF 23 A8.1
19 OF 23 A8.2
WINDOW AND DOOR DETAILS
WOOD FLAGPOLE DETAILS
20 OF 23 A8.3
21 OF 23 A8.4
SLIDING GARAGE DOOR DETAILS, SECTION, AND SCHEDULE
BUNKHOUSE STAIR DETAILS
22 OF 23 A8.5 OFFICE RAMP DETAILS
23 OF 23 A8.6 OFFICE PORCH DETAILS
SOILS AROUND SITE ARE LIKELY CONTAMINATED BY LEAD. REMOVE 3" OF
CONTAMINATED SOIL BEYOND A 10' PERIMETER OF 7 FACILITIES AFTER
TESTING AND CONSULTATION WITH EPA AND STATE AUTHORITIES.
PROVIDE NEW TOPSOIL AND REGRADE SITE TO DRAIN AWAY AT 4% SLOPE
FOR MINIMUM 10' BEYOND PERIMETER. DO NOT UNDERMINE CONCRETE
RAMPS INTO FACILITY. REGRADE SITE TO 20' BEYOND BUILDING
PERIMETERS. PROVIDE FS SPECIFIED SEED MIX TO STABILIZE AFTER
GRADING.
WELL
EXISTING HELIBASE
LEGEND
PAVED COUNTRY ROAD
BUILDINGS
OFFICE
BUNKHOUSE
DWELLING
BUNKHOUSE
SEED HOUSE
GARAGE/STORAGE
BARN
OIL HOUSE
FIRE CACHE/ SHOP 1339
1373 NIC- MODERN
1368 NIC- MODERN
1153 NIC MODERN
1122 NIC- ALREADY COMPLETED
HISTORICAL BOUNDARY
BUILDINGS
FENCES
UNDERGROUND POWER
OVERHEAD POWER
TRANSFORMER
TELEPHONE
WATER
WATER HYDRANT
SEWER
POWER POLE
SEWER LIFT STATION
STORAGE
RECREATION WAREHOUSE
BARN TO BE RESTORED
FIRE CACHE TO BE RESTORED
GAS/ OILHOUSE TO BE RESTORED
BUNKHOUSE TO BE RESTORED
OFFICE TO BE RESTORED
GARAGE/STORAGE BLDG TO BE RESTORED
STORAGE TO BE RESTORED
PROVIDE AND INSTALL NEW WOOD FLAGPOLE.
SEE SHEET A8.2
NEW BUCK AND POLE FENCE 10' BEYOND BLDG.
SCALE: 1/4" = 1'-0"
2' 4'0 8'
BUILDING #1329
BUILDING #1329 BUILDING #1329
BUILDING #1329
BUILDING #1329 BUILDING #1329 BUILDING #1329 BUILDING #1329
BUILDING #1329BUILDING #1329
BUILDING #1329
EDGE
NEW ICE AND WATER SHIELD
EXTEND 6' FROM ROOF
EXISTING WOOD RAFTERS
NEW ROOFTOP GUARD II OR EQUAL
NEW PLYWOOD SHEATHING
NEW FINISHED WOOD SHINGLES
12"
EXPOSED RAFTER TAILS,
MATCH EXISTING.
PAINTED
EXISTING SKIP SHEATHING
REPAINT EXISTING SIDING
NEW DRIP EDGE
NEW "CEDAR BREATHER" NYLON WAFFLE
DRAINAGE MATERIAL, OR EQUAL.
REPLACE DAMAGED WOOD SIDING TO MATCH EXISTING
REMOVE SOFFIT FROM FIRE CACHE
BUILDING #1329
BUILDING #1329 BUILDING #1329
BUILDING #1329 BUILDING #1329
2 X TRIM, MINIMAL TO SHOW TAIL
ALL WINDOW COMPONENTS AND TRIM SHALL BE REHABILITATED AS SPECIFIED IN SECTION 085920 ALL BROKEN GLASS AND ALL GLAZING IN WINDOWS SHALL BE REPLACED AS SPECIFIED IN SPEC SECTION 088000.
ALL HISTORIC DOORS SHALL BE REHABILITATED AS PER SPECIFICATION 085920. REPLACE ALL DOOR
HARDWARE.
ALL HISTORIC WINDOWS ARE FIXED WITH APPLIED TRIM. FIELD VERIFY ALL SIZES BEFORE UNDERTAKING WORK.
ALL HISTORIC DOORS ARE BUILT-UP UNITS WITH DECORATIVE APPLIED TRIM AS SHOWN ABOVE
LEAD BASED PAINT SHALL BE REMOVED FROM ALL SURFACES OF SIDING, DOORS AND WINDOWS AS PER 024130 AND 024134. REPAINT SIDING, DOORS AND WINDOWS TO MATCH EXISTING COLOR SCHEME
INVESTIGATE AND BID TO REPLACE ANY DAMAGED SIDING WITH IDENTICAL COMPONENTS.
THE CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING MODERN STEEL OVERHEAD DOOR
REMOVE EXISTING STEEL SIDING AND TRIM FROM THE ENTIRE FRONT OF THE FIRE CACHE.
ABATE LEAD BASED PAINT FROM ALL EXISTING WOOD SIDING, TRIM, WINDOWS AND DOORS.
THE CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING STEEL SWINGING DOOR
INVESTIGATE SIDING CONDITION W/ HISTORIC PRESERVATION CONSULTANT. REPLACE DAMAGED TRIM
REMOVE FRAME AND TRIM. PROVIDE NEW WOOD, RAISED FIVE PANEL DOOR TO MATCH HISTORIC CONFIGURATION, SEE SPECIFICATIONS/ HARDWARE LIST. REPLACE TRIM AND FRAME COMPONENTS IN KIND
PAINT ALL SIDING AND TRIM.
PROVIDE AND INSTALL NEW WOOD SLIDING GARAGE DOORS TO DUPLICATE HISTORIC CONFIGURATION DETAILS ARE SHOWN ON SHEET A.1.6. INSTALL NEW DOUBLE 2X 10 DOUG FIR NO 1 HEADERS OVER DOORS INSTALL NEW TRIM, POSTS AS SHOWN IN DETAILS ON SHEET A.1.6 WITH WOOD TRIM, SLIDING HARDWARE
PRIME/ PAINT WOOD COMPONENTS.
SCALE: 1/4" = 1'-0"
2' 4'0 8'
BUILDING #1339
BUILDING #1339
BUILDING #1339
BUILDING #1339 BUILDING #1339
AND SIDING IN KIND TO MATCH EXISTING PROFILES AND MATERIALS ON EXTERIOR OF THE FIRE CACHE.
ITEM & MODEL NUMBER
HARDWARE SCHEDULE
QUANTITYHRDWR GRP
MANUFACTURER
THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG
DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)
WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET
HINGES= 4-1/2"X4-1/2" BALL BEARING W/ FIXED PINS #BB1279NRP1 1/2 PAIR
1 EA.
1 EA.
1 EA.
1 EA.
1 EA.
PEMKO
PEMKO
PEMKO
SCHLAGE
HAGER
HAGER
LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION
FLOOR STOP= #245F
1 EA. SEE SHEET A8.3
Person door sliding door
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS
024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE FIRE CACHE, INCLUDING RAFTER
TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. THE CONTRACTOR MAY NEED TO
REMOVE FENCING ADJACENT TO BUILDING TO PERFORM WORK. REINSTALL ALL FENCING
AFTER COMPLETION.
BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN
SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE
SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION
SPECIALIST.
REMOVE AND REINSTALL EXISTING LIGHT FIXTURES AFTER ABATEMENT AND PAINTING.
REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER
SECTION 02413 AND DISPOSE OF THE WASTE AS PER SPEC 024134.
REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER
SPECIFICATION 073110.
INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT,
AND CEDAR BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.
INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN
SECTION 073111.
THE CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING STEEL SWINGING DOOR
REPLACE ALL DAMAGED TRIM AND SIDING TO MATCH EXISTING
REMOVE FRAME AND TRIM. PROVIDE NEW WOOD RAISED FIVE PANEL DOOR TO MATCH HISTORIC
CONFIGURATION, SEE SPECIFICATIONS/ HARDWARE LIST. REPLACE TRIM AND FRAME COMPONENTS IN KIND
PROFILES AND MATERIALS ON THE OTHER ELEVATIONS OF THE FIRE CACHE. PAINT SIDING AND TRIM.
REPLACE ANY DAMAGED TRIM AND SIDING TO MATCH EXISTING
PROFILES AND MATERIALS ON THE OTHER ELEVATIONS OF THE FIRE CACHE. PAINT SIDING AND TRIM.
PROVIDE AND INSTALL NEW WOOD SLIDING GARAGE DOORS TO DUPLICATE HISTORIC CONFIGURATION DETAILS ARE SHOWN ON SHEET A.8.3. INSTALL NEW DOUBLE 2X 10 DOUG FIR NO 1 HEADERS OVER DOORS INSTALL NEW TRIM, POSTS AS SHOWN IN DETAILS ON SHEET A.1.6 WITH SLIDING DOOR HARDWARE
PRIME/ PAINT WOOD COMPONENTS
REMOVE AND DISPOSE OF SOFFIT MATERIALS COVERING EXPOSED RAFTER TAILS. REPAIR/ CONSOLIDATE
WOOD TAILS AND TRIM. ABATE LEAD BASE PAINT, REPAINT.
BUILDING #1339
BUILDING #1339 BUILDING #1339
BUILDING #1339
BUILDING #1339
REMOVE ALL METAL SIDING AND TRIM FROM THIS ELEVATION
REMOVE EXISTING LIGHT FIXTURE REPLACE WITH DARK SKY KINGSTON OUTDOOR WALL SCONCE OR GOV.
APPROVED EQUAL. USE EXISTING ELECTRICAL BOX.
ABATE EXTERIOR LEAD PAINT AND REPAINT
NEW CUSTOM FIXED WOOD WINDOWS AND TRIM
SCALE: 1/4" = 1'-0"
2' 4'0 8'
CONTRACTOR TO PROVIDE AND INSTALL CUSTOM WOOD WINDOWS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE
GLASS, SET WITH GLAZING COMPOUND. WINDOWS SHALL BE PAINTED OUTSIDE AND IN.
REMOVE EXISTING WINDOW AND PREPARE OPENING FOR NEW CUSTOM WINDOW. FRAME AT BOTTOM
OF WINDOW TO CREATE UNIFORM HEIGHT FOR WINDOW OPENINGS, SEE ELEVATION.
CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD DOORS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. DOORS SHALL BE PAINTED OUTSIDE AND IN.
WINDOW TYPES 8 AND 9 SHALL BE OPERABLE SLIDING WINDOW TO ALLOW EMERGENCY EGRESS FROM
STRUCTURE WITH INSECT SCREEN. ADDITIONAL FRAMING, DRYWALL AND SHEATHING WILL BE
REQUIRED IN TYPE 9 WINDOWS TO REDUCE THE OPENING SIZE.
INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO MATCH ORIGINAL PROFILES.
INSTALL SURROUNDING WOOD TRIM AFTER CUTTING BACK OR PATCHING
SIDING WITH IN KIND MATERIALS. CAULK AROUND ALL PERIMETER.
CONSTRUCT NEW CONCRETE STAIR AND LANDING WITH HANDRAILS AT ENTRY TO BUNKHOUSE
SEE A8.4.
WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A3.2
HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED. REMOVE
INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND PREP OPENINGS FOR
REPLACEMENT.
ITEM & MODEL NUMBER
HARDWARE SCHEDULE
QUANTITYHRDWR GRP
MANUFACTURER
THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG
DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)
WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET
HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR
1 EA.
1 EA.
1 EA.
1 EA.
1 EA.
PEMKO
PEMKO
PEMKO
SCHLAGE
HAGER
HAGER
LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION
FLOOR STOP= #245F
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT
THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.
REMOVE ALL SIDING ON SOUTH ELEVATION AND REPLACE TO MATCH SIDING ON REMAINING WALL.
BACK PRIME AND PAINT NEW SIDING.
INSPECT CMU FOUNDATION, CLEAN AND INJECT CRACKS WITH TWO PART EPOXY CRACK REPAIR
SYSTEMS SUCH AS "WISE CHOICE" OR GOVERNMENT APPROVED EQUAL. CLEAN AND CUT BACK
AS RECOMMENDED BY MANUFACTURER. CREATE DOVETAIL SHAPE BEFORE REPAIRS, NOT V
SHAPE, WHICH CAN "PUSH OUT" REPAIR.
Typ
1 EA. ACORN MANUFACTURINGLATCHSET, HINGES, CLOSER KIT AZ1B1
WINDOWS 8 AND 9 SHALL HAVE REMOVABLE WOOD SCREENS CUSTOM CONSTRUCTED TO MATCH
HISTORICAL PROFILES. HOOKS EMBEDDED IN WINDOW FRAME OF NEW WINDOWS.
BUILDING #1106 NEW NEW
NEW
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE
BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, SOFFIT, FASCIA, ETC.
BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.
REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER SECTION 02413 AND
DISPOSE OF THE WASTE AS PER SPEC 024134.
REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER SPECIFICATION 073110.
INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT, AND CEDAR
BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.
INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN SECTION 073111.
BUILDING #1106
BUILDING #1106BUILDING #1106
EXISTING CONCRETE STEP TO BE DEMOLISHED AND REPLACED. SEE DETAILS ON SHEET A8.4
SCALE: 1/4" = 1'-0"
2' 4'0 8'
INSTALL SURROUNDING WOOD TRIM AFTER CUTTING BACK OR PATCHING SIDING WITH IN KIND MATERIALS. CAULK AROUND ALL PERIMETER.
HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED. REMOVE INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT. PROVIDE AND INSTALL NEW CUSTOM WOOD WINDOWS, DOORS, HARDWARE, AND TRIM AS SHOWN ON SHEET A3.1
REMOVE ANY DECORATIVE HISTORIC TRIM AND PROTECT FOR REINSTALLATION. PROVIDE AND INSTALL NEW 1
2" OSB OR PLYWOOD SKIP SHEATHING
OVER EXISTING SKIP SHEATHING.
PROVIDE AND INSTALL 3' OF ICE AND WATER SHIELD. COVER WITH 30# ASPHALT IMPREGNATED FELT. INSTALL "CEDAR BREATHER" MESH OVER ENTIRE ROOF. PROVIDE INSTALL CEDAR #1 PERFECT CEDAR SHINGLES W/ 5" EXPOSURE, STAINED AS DESCRIBED IN SPECIFICATIONS.
INVESTIGATE AND REHAB WOOD GRILL. CONSOLIDATE/ EPOXY SALVAGEABLE WOOD COMPONENTS. INSTALL INSECT SCREEN AT REAR. REPLACE ANY
ROTTED COMPONENTS IN KIND. REPAINT AND REINSTALL REHABILITATED LOUVERED VENT.
REMOVE ALL SIDING ON SOUTH ELEVATION AND REPLACE TO MATCH SIDING ON REMAINING WALLS. BACK PRIME AND PAINT NEW SIDING.
BUILDING #1106
REPAIR WOOD AT RAKE BOARD BY CONSOLIDATING/ PATCHING EXISTING COMPONENT. PAINT AND REINSTALL.
INSPECT CMU FOUNDATION, CLEAN AND INJECT CRACKS WITH TWO PART EPOXY CRACK REPAIR SYSTEMS SUCH AS "WISE CHOICE" OR GOVERNMENT APPROVED EQUAL. CLEAN AND CUT BACK AS RECOMMENDED BY MANUFACTURER. CREATE DOVETAIL SHAPE BEFORE REPAIRS, NOT V SHAPE, WHICH CAN "PUSH OUT" REPAIR.
PROVIDE AND INSTALL NEW "TEMP VENT" FOUNDATION VENTS OR GOVERNMENT APPROVED EQUAL. AUTOMATIC VENTS CLOSE WHEN TEMPERATURE GET BELOW 38 DEGREES. INSTALL IN EXISTING CONCRETE BLOCK WALL. PROVIDE TRIM AND FOAM INSULATION TO FORM A
RODENT PROOF ASSEMBLY.
BUILDING #1106
BUILDING #1106
5 EA NEW CUSTOM SINGLE HUNG
ABATE EXTERIOR LEAD PAINT AND REPAINT
BUILDING # 1203
BUILDING # 1203
BUILDING # 1203
WOOD WINDOW AND TRIM
CONTRACTOR TO PROVIDE AND INSTALL CUSTOM WOOD WINDOWS IN PROFILES SHOWN ABOVE.
MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. PROVIDE
TRUE MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. WINDOWS SHALL BE
PAINTED OUTSIDE AND IN.
CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD DOORS IN PROFILES SHOWN ABOVE.
MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE
MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. DOORS SHALL BE PAINTED
OUTSIDE AND IN.
INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO
MATCH ORIGINAL PROFILES.
ITEM & MODEL NUMBER
HARDWARE SCHEDULE
QUANTITYHRDWR GRP
MANUFACTURER
THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG
DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)
WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET
HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR
1 EA.
1 EA.
1 EA.
1 EA.
1 EA.
PEMKO
PEMKO
PEMKO
SCHLAGE
HAGER
HAGER
LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION
FLOOR STOP= #245F
1 EA. LATCHSET, HINGES, CLOSER KIT = AZ1BI . ACORN MNFCTRNG
1 EA NEW CUSTOM SINGLE HUNG
WOOD WINDOW AND TRIM
THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG
DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)
WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET
HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP3 PAIR
1 EA.
1 EA.
1 EA.
1 EA.
2 EA.
LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION
FLOOR STOP= #245F
INSTALL NEW WOOD WINDOWS AND SURROUNDING WOOD TRIM. CAULK AROUND ALL PERIMETER.
DEMOLISH AND DISPOSE OF EXISTING CONCRETE PORCH. SHORE COLUMNS. CONSTRUCT NEW
WOOD FRAMED PORCH AT ENTRY TO OFFICE. SEE DETAILS ON A8.6.
WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A4.2
HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. (MUNTINS HAVE BEEN REMOVED) REMOVE AND DISPOSE OF INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND
PREP OPENINGS FOR REPLACEMENT.
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.
BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE
FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.
PROVIDE AND INSTALL NEW REPLICA OF HISTORIC WOOD DOOR(S) AND FRAMING. SEE DOOR
SCHEDULE FOR DETAILS AND HARDWARE SCHEDULE.
DEMOLISH AND DISPOSE OF EXISTING CONCRETE STOOP. CONSTRUCT NEW WOOD FRAMED ADA
RAMP AND HANDRAILS AS SHOWN IN DETAILS ON SHEET A8.5
PROVIDE AND INSTALL NEW REMOVABLE WOOD SCREENS AND
STORM WINDOWS TO MATCH HISTORICAL PROFILES, WOOD WITH
HOOKS AT NEW WOOD WINDOW FRAME.
PEMKO
PEMKO
PEMKO
SCHLAGE
HAGER
HAGER
REMOVABLE STORM WINDOW REMOVABLE INSECT SCREEN
REMOVABLE STORM WINDOW REMOVABLE INSECT SCREEN
BUILDING # 1203
BUILDING # 1203BUILDING # 1203
BUILDING # 1203
ABATE EXTERIOR LEAD PAINT AND REPAINT
BUILDING # 1203
REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD
BASED PAINT AS PER SECTION 02413 AND DISPOSE OF
THE WASTE AS PER SPEC 024134.
REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM
AS PER SPECIFICATION 073110.
INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD,
UNDERLAYMENT, AND CEDAR BREATHER OVER SKIP SHEATHING.
SPECIFICATION 073110.
INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH
FINISH SPECIFIED IN SECTION 073111.
ROOF NOTES
KEYED NOTES
INSTALL NEW WOOD WINDOWS AND SURROUNDING WOOD TRIM AFTER CUTTING BACK OR PATCHING
SIDING WITH IN KIND MATERIALS. CAULK AROUND ALL PERIMETER.
DEMOLISH AND DISPOSE OF EXISTING CONCRETE PORCH. SHORE COLUMNS. CONSTRUCT NEW
WOOD FRAMED PORCH AT ENTRY TO OFFICE. SEE DETAILS ON A8.6.
WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A4.2
HISTORIC WINDOW AND DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. (MUNTINS HAVE BEEN REMOVED) REMOVE AND DISPOSE OF INAPPROPRIATE DOORS, WINDOWS AND HARDWARE AND
PREP OPENINGS FOR REPLACEMENT.
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.
BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE
FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.
PROVIDE AND INSTALL NEW REPLICA OF HISTORIC WOOD DOOR(S) AND FRAMING. SEE DOOR
SCHEDULE FOR DETAILS AND HARDWARE SCHEDULE.
DEMOLISH AND DISPOSE OF EXISTING CONCRETE STOOP. CONSTRUCT NEW WOOD FRAMED ADA
RAMP AND HANDRAILS AS SHOWN IN DETAILS ON SHEET A8.5
INSPECT AND RESTORE EXISTING WOOD LOUVERED GRILL. EPOXY EXISTING COMPONENTS.
INSTALL INSECT SCREEN AT REAR AND REINSTALL.
REMOVE AND INSTALL NEW LIGHT IN EXISTING ELECTRICAL BOX. PROVIDE DARK SKY KINGSTON
OUTDOOR WALL SCONCE BY WORLD IMPORTS OR GOVERNMENT APPROVED EQUAL.
BUILDING #1327
LEAD BASED PAINT SHALL BE REMOVED FROM ALL SURFACES OF DOORS AND WINDOWS AS PER 024130
AND 024134. REPAINT DOORS/ WINDOWS TO MATCH EXISTING COLOR SCHEME
ABATE LEAD BASED PAINT
ABATE LEAD BASED PAINT REHAB DOOR CONSTRUCT WOOD DOOR REPLICA
ABATE EXTERIOR LEAD PAINT AND REPAINT
ITEM & MODEL NUMBER
HARDWARE SCHEDULE
QUANTITYHRDWR GRP
MANUFACTURER
THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG
DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)
WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET
HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR
1 EA.
1 EA.
1 EA.
1 EA.
1 EA.
PEMKO
PEMKO
PEMKO
SCHLAGE
HAGER
HAGER
LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION
FLOOR STOP= #245F
WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL
REPAIR. SEE SHEET A5.2
REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST.
ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW
INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS
INSIDE AND OUT. CONSTRUCT NEW WOOD WINDOW SCREENS AND STORM WINDOWS FOR
SLIDING WINDOWS AS SHOWN HERE.
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS
024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER
TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A
PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM
TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE
FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.
REMOVE PLYWOOD SURROUNDING DOOR. REFRAME 2 X 4 WALL, VERIFY AND FRAME
2'-8" X 6'-8" DOOR OPENING AND INSTALL NEW EXTERIOR GRADE 1
2" OSB SHEATHING.
WALL SHALL CONSTRUCTED TO ALLOW FLUSH INSTALLATION OF NEW SIDING TO MATCH
EXISTING SIDING. INSTALL FLUSH TRIM AROUND OPENING, INSTALL NEW DOOR.
CONSTRUCT WOOD DOOR REPLICA
CONTRACTOR TO REHABILITATE WOOD WINDOWS IN PROFILES SHOWN ABOVE AS PER SECTION 085920. MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. ALL BROKEN GLASS AND ALL GLAZING IN WINDOWS SHALL BE REPLACED AS SPECIFIED IN SPEC SECTION 088000 WINDOWS SHALL BE PAINTED
OUTSIDE AND IN.
CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD PERSONNEL DOORS IN PROFILES SHOWN ABOVE.
MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. DOORS SHALL BE PAINTED
OUTSIDE AND IN.
WINDOW TYPE 12 REQUIRES CONSTRUCTION OF NEW REMOVABLE WOOD SCREENS AND WOOD
STORM WINDOWS. INSTALL HOOKS ON EXISTING WINDOW FRAMES TO SUPPORT. PAINT ALL WOOD
COMPONENTS.
REHABILITATE OR INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO MATCH ORIGINAL
PROFILES.
& REHAB WINDOW
ABATE LEAD BASED PAINT
& REHAB WINDOW
HISTORIC PERSONNEL DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. REMOVE AND
DISPOSE OF INAPPROPRIATE DOORS AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT.
INSPECT AND REPAIR TRIM, OR INSTALL NEW TRIM IN KIND TO MATCH HISTORIC PROFILES. PROVIDE AND INSTALL NEW HISTORIC WOOD DOOR REPLICAS. PAINT ALL WOOD COMPONENTS INSIDE AND OUT.
PROVIDE NEW HARDWARE.
REHAB HISTORIC DOOR AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST.
ABATE LEAD BASED PAINT, INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF
EPOXY. REPAINT DOOR INSIDE AND OUT. REMOVE HARDWARE, CLEAN, AND REINSTALL.
REPLACE ANY NON-FUNCTIONAL HARDWARE IN KIND.
CONTRACTOR TO REHABILITATE LARGE WOOD SWINGING DOOR IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOOR IN KIND.CONSOLIDATE DAMAGED WOOD COMPONENTS OR REPLACE IN KIND AFTER CONSULTING W/ HISTORIC PRESERVATION SPECIALIST. DOOR SHALL BE PAINTED OUTSIDE AND IN.
2 EA
BUILDING #1327
BUILDING #1327BUILDING #1327
BUILDING #1327
REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER SECTION 02413 AND
DISPOSE OF THE WASTE AS PER SPEC 024134.
REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER SPECIFICATION 073110.
INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT, AND CEDAR
BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.
INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN SECTION 073111.
BUILDING #1106
WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A5.2
REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS INSIDE AND OUT. CONSTRUCT NEW WOOD WINDOW SCREENS AND STORM
WINDOWS FOR SLIDING WINDOWS.
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH
HISTORIC PRESERVATION SPECIALIST.
REMOVE PLYWOOD SURROUNDING DOOR. REFRAME 2 X 4 WALL, VERIFY AND FRAME 2'-8" X 6'-8" DOOR OPENING AND
INSTALL NEW EXTERIOR GRADE 1
2" OSB SHEATHING. WALL SHALL CONSTRUCTED TO ALLOW FLUSH INSTALLATION OF NEW
SIDING TO MATCH EXISTING SIDING. INSTALL FLUSH TRIM AROUND OPENING, INSTALL NEW DOOR.
HISTORIC PERSONNEL DOORS HAVE BEEN DESTROYED OR ALTERED SIGNIFICANTLY. REMOVE AND DISPOSE OF INAPPROPRIATE DOORS AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT. INSPECT AND REPAIR TRIM, OR INSTALL NEW TRIM IN KIND TO MATCH HISTORIC PROFILES. PROVIDE AND INSTALL NEW HISTORIC WOOD DOOR REPLICAS. PAINT
ALL WOOD COMPONENTS INSIDE AND OUT. PROVIDE AND INSTALL NEW HARDWARE.
REHAB HISTORIC DOOR AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT DOOR INSIDE AND OUT. REMOVE
HARDWARE, CLEAN, AND REINSTALL. REPLACE ANY NON-FUNCTIONAL HARDWARE IN KIND.
WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A6.2
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.
BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE
FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.
ABATE EXTERIOR LEAD PAINT AND REPAINT
REMOVE EXISTING CONCRETE APRON. PROVIDE AND INSTALL 4" THICK CONCRETE PAD WITH 6" OF
GRAVEL FILL UNDER SLAB.
REPAIR WOOD OVERHEAD DOOR. CONSOLIDATE WOOD PARTS, REPLACE ROTTED COMPONENTS IN
KIND AS DESCRIBED IN SECTION 085920. ABATE LEAD BASED PAINT. REPAINT INTERIOR AND EXTERIOR. REPAIR WOOD TRIM AND REPAINT. INSPECT DOOR HARDWARE. REPLACE HASP, AND DOOR
PULL, CLEAN INTERIOR TRACK.
ABATE EXTERIOR LEAD PAINT AND REPAINT
2 EACH
ABATE EXTERIOR LEAD PAINT AND REPAINT
1 EACH
ALL WINDOW COMPONENTS AND TRIM SHALL BE REHABILITATED AS SPECIFIED IN SECTION 085920 ALL BROKEN GLASS AND ALL GLAZING IN WINDOWS SHALL BE REPLACED AS SPECIFIED IN SPEC SECTION 088000.
HISTORIC DOOR SHALL BE REHABILITATED AS PER SPECIFICATION 085920. REMOVE FUNCTIONAL ALL DOOR HARDWARE AND REMOVE PAINT. REINSTALL FUNCTIONAL HARDWARE AFTER DOOR REPAIR. REPLACE HARDWARE NOTED ABOVE
ALL HISTORIC WINDOWS ARE FIXED WITH APPLIED TRIM
ALL HISTORIC DOORS ARE BUILT-UP UNITS WITH DECORATIVE APPLIED TRIM AS SHOWN ABOVE
LEAD BASED PAINT SHALL BE REMOVED FROM ALL SURFACES OF DOORS AND WINDOWS AS PER 024130 AND 024134.
REPAINT DOORS/ WINDOWS TO MATCH EXISTING COLOR SCHEME
INVESTIGATE AND BID TO REPLACE ANY DAMAGED SIDING WITH IDENTICAL COMPONENTS
ITEM & MODEL NUMBER
HARDWARE SCHEDULE
QUANTITYHRDWR GRP MANUFACTURER
1 1 EA. AMERICAN LOCKHEAVY DUTY CENTERED HOLE HASP A535
1 EA. YALEREMOVABLE CORE PADLOCK, MODEL #424
1 EA. BALDWIN 4" x 1 1/8" BRONZE SASH PULL MODEL #470
REMOVE EXISTING WOOD SHINGLES COVERED WITH LEAD BASED PAINT AS PER SECTION 02413 AND
DISPOSE OF THE WASTE AS PER SPEC 024134.
REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER SPECIFICATION 073110.
INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD, UNDERLAYMENT, AND CEDAR
BREATHER OVER SKIP SHEATHING. SPECIFICATION 073110.
INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH SPECIFIED IN SECTION 073111.
BUILDING #1330
BUILDING #1330
SCALE: 1/4" = 1'-0"
2' 4'0 8'
BUILDING #1330
BUILDING #1330 BUILDING #1330
WOOD SHINGLE ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE INFORMATION ADJACENT.REMOVE
AND REINSTALL EXISTING EXHAUST FAN AFTER ROOF INSTALLATION
REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS INSIDE AND OUT. CONSTRUCT NEW WOOD WINDOW SCREENS AND STORM
WINDOWS FOR SLIDING WINDOWS.
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE OFFICE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH
HISTORIC PRESERVATION SPECIALIST.
REHAB HISTORIC DOOR AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST. ABATE LEAD BASED PAINT, INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT DOOR INSIDE AND OUT. REMOVE
HARDWARE, CLEAN, AND REINSTALL. REPLACE HARDWARE AS NOTED ON SHEET A6.1.
HARDWARE SCHEDULE
QUANTITYHRDWR GRP
MANUFACTURER
THRESHOLD= 8 1/8", ACCESSIBLE, W/THERMAL BREAK, #254X4AFG
DOOR SHOE= W/VINYL SEAL INSERT, #217AV (SEE NOTE 2 BELOW)
WEATHERSTRIP= S88D, PRESSURE SENSITIVE SILICON GASKET
HINGES= 4-1/2"X4-1/2" BALL BEARING W/FIXED PINS #BB1279NRP1 1/2 PAIR
1 EA.
1 EA.
1 EA.
1 EA.
1 EA.
PEMKO
PEMKO
PEMKO
SCHLAGE
HAGER
HAGER
LATCHSET= #F10PLY KNOB, 620 FINISH ENTRY FUNCTION
FLOOR STOP= #245F
BUILDING #1328
SCALE: 1/4" = 1'-0"
2' 4'0 8'
ABATE EXTERIOR LEAD PAINT AND REPAINT
NOTES
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC.
BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS AND TRIM TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY. EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST. THIS FACILITY HAS BEEN
BADLY DAMAGED BY LIVESTOCK. EVALUATE AND REPLACE MISSING COMPONENTS WITH IN KIND
MATERIALS.
METAL ROOF WILL BE REPLACED IN KIND AFTER STRUCTURAL REPAIR. SEE SHEET A7.2
REHAB HISTORIC WINDOWS AFTER CONSULTATION WITH HISTORIC PRESERVATION SPECIALIST.
ABATE LEAD BASED PAINT, REPLACE ANY BROKEN GLASS AND REGLAZE ENTIRE WINDOW
INSPECT AND CONSOLIDATE WOOD COMPONENTS IN NEED OF EPOXY. REPAINT WINDOWS
INSIDE AND OUT.
HISTORIC PERSONNEL DOOR HAS BEEN DESTROYED BY LIVESTOCK. REMOVE AND DISPOSE OF DOOR AND HARDWARE AND PREP OPENINGS FOR REPLACEMENT. INSPECT AND REPAIR TRIM, OR INSTALL NEW TRIM IN KIND TO MATCH HISTORIC PROFILES. PROVIDE AND INSTALL NEW HISTORIC WOOD DOOR
REPLICA. PAINT ALL WOOD COMPONENTS INSIDE AND OUT. PROVIDE NEW HARDWARE.
NEW NEW
NEW
CONTRACTOR TO PROVIDE AND INSTALL CUSTOM WOOD WINDOWS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL WINDOWS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE
GLASS, SET WITH GLAZING COMPOUND. WINDOWS SHALL BE PAINTED OUTSIDE AND IN.
CONTRACTOR TO PROVIDE AND INSTALL NEW CUSTOM WOOD DOORS IN PROFILES SHOWN ABOVE. MATCH DETAILS AND ASSEMBLY OF ORIGINAL DOORS THROUGHOUT THE SITE IN KIND. PROVIDE TRUE MUNTINS AND SINGLE PANE GLASS, SET WITH GLAZING COMPOUND. DOORS SHALL BE PAINTED OUTSIDE AND IN.
INSTALL NEW WOOD TRIM AROUND WINDOWS AND DOORS TO MATCH ORIGINAL PROFILES.
ABATE LEAD BASED PAINT AND DISPOSE OF WASTE AS REQUIRED BY SPECIFICATIONS 024130 AND 024134 FOR THE ENTIRE EXTERIOR OF THE BUNKHOUSE, INCLUDING RAFTER TAILS, SIDING, DOORS, WINDOWS, SOFFIT, FASCIA, ETC. BUDGET TO REPLACE A PORTION OF THE EXISTING, ROTTED SIDING AS DESCRIBED IN SPECIFICATIONS TO MATCH EXISTING PROFILES AFTER INVESTIGATING AT THE SITE. REPAINT THE ENTIRE FACILITY.
EVALUATE CONDITIONS WITH HISTORIC PRESERVATION SPECIALIST.
BUILDING #1328
BUILDING #1328
BUILDING #1328BUILDING #1328
REMOVE EXISTING METAL ROOFING.
REMOVE, CLEAN, PAINT AND REINSTALL HISTORIC ROOF TRIM AS PER
SPECIFICATION 073110.
INSTALL NEW WOOD ROOF SHEATHING, ICE AND WATER SHIELD,
UNDERLAYMENT, AND CEDAR BREATHER OVER SKIP SHEATHING.
SPECIFICATION 073110.
INSTALL NEW CEDAR SHINGLES AFTER SPRAYING WITH FINISH
SPECIFIED IN SECTION 073111.
REMOVE EXISTING DOOR AND THRESHOLD. REPLACE WOOD DOOR IN KIND, PAINT AND PROVIDE NEW DOOR HARDWARE. INSPECT WOOD FRAME
AND REPLACE ANY ROTTED COMPONENTS IN KIND.
REMOVE AND REPLACE WOOD WINDOWS IN KIND. REPLACE MISSING WOOD SILLS . PAINT WINDOWS INSIDE AND OUT.
REMOVE AND DISPOSE OF EXISTING CORRUGATED ROOFING. INSTALL SHEATHING, UNDERLAYMENT AND WOOD SHINGLES. SEE DESCRIPTION ON
THIS SHEET.
REPLACE CORNER TRIM DESTROYED BY HORSES WITH IN KIND PRODUCT.
PROVIDE AND INSTALL NEW WOOD POLE FENCE AT 10' BEYOND FACILITY PERIMETER. SEE DETAILS FOR FENCE CONTRACTION AND GATE DETAILS.
TIE INTO EXISTING FENCE AS DIRECTED BY THE COR.
SCALE: 1/4" = 1'-0"
2' 4'0 8'
BUILDING #1328
WOODEN FLAGPOLE FABRICATED FROM
TAPERED TRUE LODGEPOLE PINE, TREATED AND
PAINTED WHITE.
8" BRASS BALL AT FLAGPOLE TERMINATION W/
HOLE DRILLED AT TOP AND BOTTOM. LAG
SCREW THE BALL TO THE TERMINATION.
APPROXIMATELY 41
2" DIA AT TOP OF POLE.
4" X 1" METAL BAND WITH PULLEY FOR ROPE
ATTACHMENT.
ROPE W/ SNAP HOOK TO ATTACH FLAG.
ROPE TIE AT BASE
APPROXIMATELY 10" DIA AT BASE
2 EACH APPROXIMATELY 8" DIA TREATED,
PAINTED STUBS, EXTENDED 6' BELOW GRADE.
LAG BOLT W/ 3
4" x 26" GALVANIZED LAGS, W/
NUTS/ WASHERS.
6'-6" X 3'-3" CONCRETE BASE
DOOR 07
DOOR 07
A8.3
GARAGE DOOR & COLUMN DETAILS
HARDWARE SCHEDULE/DESCRIPTION:
4-EACH.H-01
ITEM QUANTITY LOCATION DESCRIPTION:
GARAGE DOOR
HEAD.
12-EACH.H-02 BRACKET, OVERHEAD DOUBLE CENTER=ITEM #0031.00069 AS MANUFACTURED BY:
RICHARDS-WILCOX CO., AURORA. IL. OR AN APPROVED EQUAL.
2-EACH.
10' LONG.
H-04
TRACK=ITEM #0031.00115/ 0031.00117 AS MANUFACTURED BY:
RICHARDS-WILCOX CO., AURORA, IL. OR AN APPROVED EQUAL.
GARAGE DOOR
HEAD.
GARAGE DOOR
HEAD.
2-EACH.H-05 DOOR LATCH ASSEMBLY=ITEM #0152.00023 WITH PADLOCKS AS MANUFACTURED BY:
RICHARDS-WILCOX CO., AURORA, IL. OR AN APPROVED EQUAL.
GARAGE DOOR
JAMB.
2 EA-PAIR
(RIGHT/LEFT)H-06 POST CAPS= MODEL #LPC6 AS MANUFACTURED BY:
SIMPSON STRONG-TIE CO., OR AN APPROVED EQUAL.
TOP OF NEW
POST.
3-EACH.H-07 POST BASE= MODEL #ABU46, STAND OFF POST, AS MANUFACTURED BY:
SIMPSON STRONG-TIE CO., OR AN APPROVED EQUAL.
BTM. OF NEW
POSTS.
EXISTING CONCRETE
FLOOR.
NEW 2 X FILLER.
NEW 4" X 6"
POST.
NEW TRIM.
A
PP
R O
X
NEW TRIM.
NEW 1 X TRIM.
NEW METAL
COLUMN CAP.
(SEE SCHEDULE
THIS SHEET).
NEW 1 X FIR FRIEZE.
NEW TRIM.
(2)-2" X 10"
DOUG FIR NO 1HEADER.
NEW METAL
COLUMN BASE.
(SEE SCHEDULE
THIS SHEET).
H-06
H-07
H-07
MANUFACTURERS NAMES AND MODEL NUMBERS ARE GIVEN TO ESTABLISH A REQUIRED FUNCTION AND ACCEPTABLE QUALITY. PRODUCTS OF OTHER MANUFACTURERS MAY BE SUBMITTED FOR REVIEW AND APPROVAL.
H-03
GARAGE DOOR
HEAD.
TRUCK/ HANGER ASSEMBLY=ITEM #3110 AS MANUFACTURED BY:
RICHARDS-WILCOX CO., AURORA. IL. OR AN APPROVED EQUAL.
3 EACH 2 X 4 COLUMN
H-01
4 EACH "END BLINDS"
H-02
12 EACH "DOUBLE CENTER"
0031.00050 RICHARDS-WILCOX
0031.00069 RICHARDS-WILCOX
1 EACH "DOUBLE LOCK JOINT"2 EACH DOOR LATCH W/
H-03
22 LF OF RICHARDS-WILCOX 31 TRACK
H-04
RICHARDS-WILCOX 3100 TRUCK/ HANGER
ASSEMBLY 8 TOTAL, EVENLY SPACED, 2 DOORS
BOLT AS RECOMMENDED BY MANUFACTURER
1 X 8 CLEAR VERTICAL GRAIN DOUGLAS FIR
TRIM EDGE W/ QUARTERROUND
PRIME AND PAINT COMPONENTS
1 X 4 OR 6 CLEAR VERTICAL GRAIN DOUGLAS FIR
TONGUE AND GROOVE FLOORING, Vertically ORIENTED
PRIME AND PAINT COMPONENTS
A8.3
A8.3
BEYOND
1 X 8 CLEAR VERTICAL GRAIN DOUGLAS FIR
TRIM EDGE W/ QUARTERROUND
PRIME AND PAINT COMPONENTS
1 X 4 OR 6 CLEAR VERTICAL GRAIN DOUGLAS FIR
TONGUE AND GROOVE FLOORING, Vertically ORIENTED
PRIME AND PAINT COMPONENTS
1 X 12 CLEAR VERTICAL GRAIN
TRIM EDGE W/ QUARTERROUND
PRIME AND PAINT COMPONENTS
DOUGLAS FIRDUPLICATE ORIGINAL
NEW METAL
COLUMN BASE.
(SEE SCHEDULE
THIS SHEET).
POWER COATED
END BIND=ITEM #0376.00087 AS MANUFACTURED BY:
RICHARDS-WILCOX CO., AURORA. IL. OR AN APPROVED EQUAL.
4-EACH.
6' LONG.
8-EACH.
H-05
HASPS/ PADLOCK AT
OUTSIDE JAMBS
DETAIL AT COLUMN BASE/DOOR BOTTOM
SCALE: 3"= 1'-0"
SCALE: 3" = 1'-0"
2" 4"0 8"
PLAN VIEW COLUMN AND DOORS
SCALE: 3"= 1'-0"
SECTION THRU DOOR HEADER
SCALE: 3"= 1'-0"
ENGINEERED FILL
CONCRETE STAIRS WITH 11" TREADS, METAL NOSING
#4 BAR@ 12" OC, BOTH DIRECTIONS
CONCRETE FOOTING UNDER POST
12" X 12" W/ 4 EACH #4 HORIZONTAL
AND 3 EACH #4 VERTICAL UNDER RAIL POST
2 EA #4 BAR
4" THICK SLAB #4 12" OC BOTH DIRECTIONS
WOOD GUARD RAIL SEE 2/A8.4
2 X 2 REDWOOD BALUSTRADES
PAINTED SECURE END POST TO EXISTING WALL.
4 X 4 REDWOOD POSTS
4 X 4 PAINTED REDWOOD POSTS
SIMPSON STRONG TIE PB44- ZMAX
12" x 12" CONCRETE FOOTING
2 X 4 PAINTED REDWOOD RAIL
2 X 2 PAINTED WOOD BALUSTRADE
REINFORCE WITH 3 EA #4 HORIZONTAL
4 EA #4 VERTICAL
2 X 4 PAINTED REDWOOD RAIL
CONNECT W/ SIMPSON LSU24
2 X 6 SHAPED REDWOOD TOP RAIL,
PAINTED, SECURED TO POST W/ NAILS
2 X 4 PAINTED SHAPED REDWOOD RAIL
CONNECT W/ SIMPSON LSU24
STAIR BEYOND
LOCATE TO ALIGN W RAIL AT DECKING
CONSTRUCT RAIL RETURN W/ THIS COMPONENT
CUSTOM PAINTED STEEL BRACKET 8" X 8" X 1/4"
WELDED TO 4"X 4" X1/4" X 6" STEEL TUBE
4 EA 1/2" X 4" EXPANSION ANCHORS
LAG TO POST AT TUBING
CUSTOM PAINTED STEEL BRACKET 8" X 8" X 1/4"
WELDED TO 4"X 4" X1/4" X 6" STEEL TUBE
4 EA 1/2" X 2 5/8" REDHEAD EXPANSION ANCHORS
LAG TO POST AT TUBING
8" CONCRETE FOUNDATION WALL
REINFORCED W/ # 4 REBAR EVERY 18"
BOTH DIRECTIONS
8" CONCRETE FOUNDATION WALL REINFORCED W/ # 4 REBAR
EVERY 18" BOTH DIRECTIONS
CONCRETE ACCESSIBLE RAMP 1:12 SLOPE W/ REDWOOD
POSTS, BALUSTRADES AND DECORATIVE RAILING.
5' X 5' X 4" THICK CONCRETE PAD AT BASE OF RAMP.
5' X 5' X 4" THICK CONCRETE PAD AT
BASE OF RAMP. TIE TO EXISTING
SIDEWALK.
ENGINEERED FILL
CONCRETE ACCESSIBLE RAMP 1:12 SLOPE
W/ REDWOOD POSTS, BALUSTRADES AND
DECORATIVE RAILING.
18" X 18" #4 REBAR TO TIE WALL TO
SLAB
STEM WALL TO 30" BELOW GRADE
LINE OF FINISHED FLOOR, EXISTING
BUILDING. REMOVE SIDING AT
CONCRETE WALL AND LINE FRAMED
WALL WITH ICE AND WATER SHIELD
BEFORE POURING FOUNDATION
WALL.
4 X 4 REDWOOD POSTS, PAINTED
BUILT UP REDWOOD RAILING,
PAINTED .
PAINTED STEEL BRACKETS W/
EXPANSION ANCHORS INTO
CONCRETE.
FILL IN INTERSTITIAL SPACE W/ WEED MAT AND 4" OF
GRAVEL UPON COMPLETION.
LINE OF EXTERIOR WALL, HISTORIC OFFICE.
PAINTED STEEL BRACKETS W/ EXPANSION ANCHORS
INTO CONCRETE. FLAT AND SLOPED
CONFIGURATION, SEE DETAILS ADJACENT.
4" X 4" X 1
4" STEEL TUBE, 4" TALL, PREDRILLED FOR 2 EACH
LAG CONNECTION TO POSTS.
4" STEEL PLATE, FILLET WELDED TO TUBE, 4 EA
PREDRILLED FOR 4 EACH 3
8" "TRUBOLT" EXPANSION
ANCHORS.
8" X 25
8" WEDGE ANCHORS BY "REDHEAD" OR EQUAL.
15 EACH FLAT
CONNECTORS FOR RAMP
4 EACH SLOPED
CONNECTORS FOR RAMP
BUILT UP REDWOOD RAILING,
PAINTED .
12" RAILING RETURN
FRAMED W SHAPED
REDWOOD, PAINTED.
BUILDING # 1203
8" CONCRETE FOUNDATION
#4 REBAR 18" OC BOTH DIRECTIONS
2 X 6 REDWOOD DECKING
FOR STAIRS, RISERS AND PORCH
ROUND PROFILE AS SHOWN
TREATED WOOD 2 X'S
STRINGERS AND HORSES 4' OC
TREATED WOOD 2 X 8 FOR
LEDGER, ANCHOR W/ 1/2"
16"
EQ
EQ
EQ
12"
12"
4 X 4 X 1/4" ANGLE
WITH LAG TO HORSE
1/2" ANCHOR BOLT TO CONCRETE
CONTINUOUS CONCRETE FOOTING
99'-1 1/2"
TOP OF WALL
FILL UNDER PORCH
6'-0"
EXISTING CONCRETE FOUNDATION WALL
FINISHED FLOOR AT 100'
PAINTED 1 X 6 TRIM
EXISTING EXTERIOR WALL
AFTER CUTTING BACK FOR PORCH
REPAINT EXISTING SIDING
REPLACE SIDING AS NEEDED
2 X 10 LEDGER SECURE W/
8"
16"
X 3 3/8" EXPANSION ANCHOR
AT 32" OC
REPLACE OR CONSOLIDATE
DAMAGED COMPONENTS
EXISTING COLUMN, LOWER INTO PLACE
2 x 10 DOUG FIR NO 2
16" OC AND UNDER COLUMN
3/8" LAG BOLT 18" OC
2 ea #4 REBAR LONGITUDINALLY AND
CONTINUOUS CONCRETE FOOTING
#4 18" OC TRANSVERSELY
#4 18" OC TRANSVERSELY
2 x 10 DOUG FIR NO 2
16" OC AND UNDER COLUMN
TREATED WOOD 2 X'S
STRINGERS AND HORSES 4' OC
COLUMN ABOVE
2 X 6 REDWOOD DECKING
FOR STAIRS, RISERS AND PORCH
ROUND PROFILE AS SHOWN
TREATED WOOD 2 X 8 FOR
SILL, ANCHOR W/ 1/2"
X 6" EXPANSION ANCHOR
AT 32" OC
2 X 10 LEDGER SECURE W/
3/8" LAG BOLT 18" OC
2 EA 2 x 10 DOUG FIR NO 2
HUNG W SIMPSON HU410
HUNG W SIMPSON HU210'S
REPLACE OR CONSOLIDATE
EXISTING COLUMN, LOWER INTO PLACE
COVED TRIM
2 X REDWOOD, PAINTED
COVED TRIM
2 EA 2 x 10 DOUG FIR NO 2
HUNG W SIMPSON HU410
8" CONCRETE FOUNDATION
#4 REBAR 18" OC BOTH DIRECTIONS
1/2" ANCHOR BOLT TO CONCRETE
| T-1 |
| S.1 |
| S.2 |
| A1.1 |
| A1.2 |
| A2.1 |
| A2.2 |
| A3.1 |
| A3.2 |
| A4.1 |
| A4.2 |
| A5.1 |
| A5.2 |
| A6.1 |
| A6.2 |
| A7.1 |
| A7.2 |
| A8.1 |
| A8.2 |
| A8.3 |
| A8.4 |
| A8.5 |
| A8.6 |