S
SB#XX
BURIED ELECTRIC
EXISTING GATE VALVE & HYDRANT
WATER SERVICE & CURB STOP
PROPOSED WATERMAIN, VALVE, & HYDRANT
PROPOSED WATER SERVICE & CURB STOP
EXISTING SANITARY SEWER & MANHOLE
EXISTING STORM SEWER & INLET
PROPOSED STORM SEWER & INLET
PROPOSED MANHOLE & SEWER MAIN
BURIED CABLE TELEVISION
BURIED TELEPHONE
BURIED FIBER OPTICS
EXISTING CURB & GUTTER
PROPOSED CURB & GUTTER
EXISTING SIDEWALK
PROPOSED SIDEWALK
EXISTING CULVERT PIPE
FENCE LINE
EXISTING FORCEMAIN
BURIED GAS & VALVE
EXISTING WATER MAIN
POWER POLE & GUY
SOIL BORING
LIGHT POLE
PEDESTAL
STREET SIGN
TREE - CONIFEROUS
SILT FENCE
PROPERTY LINE
IRON PIPE
MAILBOX
EROSION BALES
TREE TO BE REMOVED
TREE - DECIDUOUS
CONTROL POINT
TREE LINE
RIGHT-OF-WAY
BASELINE
FLAGPOLE
DRAINAGE ARROW
LEGEND
RAILROAD TRACKS
WM
FM
SAN
SS
E
G
TV
T
FO
SS
PROPOSED CULVERT PIPE
IRON ROD
TYPICAL SILT FENCE INSTALLATION
AT SITE PERIMETER DETAIL
NTS
PERSPECTIVE VIEW
SECTION
GENERAL NOTES:
2 INCH x 2 INCH
HARDWOOD POSTS
OR EQUIVALENT
SHALL BE BACKFILLED AND COMPACTED.
4 INCH DEEP V-TRENCH. TRENCH
4 INCH x 4 INCH TRENCH OR A
MINIMUM 8 INCHES OF FABRIC IN A
FLOW
UNDISTURBED
GROUND
FILTER FABRIC
SEE SPECS.
FLO
W
FLO
W
3’-0" C/C (FIELD CONST’D.)
8’-0" C/C (FACTORY ASSM’D.)
M A
X
M A
X
M
IN
ENDS OF FENCE SHALL BE TURNED UPSLOPE 1 TO 2 FEET IN
ELEVATION TO PREVENT FLANKING.
STAPLE FABRIC WITH 1/2 INCH (MINIMUM) STAPLES TO THE
UPSLOPE SIDE OF THE POSTS.
WHEN TWO SECTIONS OF FILTER FABRIC ADJOIN EACH OTHER
THEY SHALL BE OVERLAPPED BY SIX INCHES AND FOLDED.
1.
2.
3.
A B L
2:1 M A
X
2:1 M A
X
L = THE DISTANCE SUCH THAT POINTS
A AND B ARE OF EQUAL ELEVATION
SIDE VIEW
STONE OR ROCK DITCH CHECK
(TEMPORARY OR PERMANENT)
6:1 NOR.
6:1 NOR.
2’ DROP
36" MAX
10" MIN
FLOW
NTS
CONSTRUCTION SITE
EROSION CONTROL REQUIREMENTS
1.) SECTION NR216.46 OF WISCONSIN STATE ADMINISTRATIVE CODE IDENTIFIES REQUIREMENTS
FOR CONSTRUCTION SITE AND POST-CONSTRUCTION EROSION CONTROL. IT IS THE INTENT
OF THESE PLANS TO SATISFY THESE REQUIREMENTS. THE METHODS AND STRUCTURES USED
TO CONTROL EROSION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR
SHALL IMPLEMENT AN APPROPRIATE MEANS OF CONTROLLING EROSION DURING SITE OPERATION
AND UNTIL THE VEGETATION IS RE-ESTABILISHED. ADJUSTMENTS TO THE CONTROL SYSTEM
SHALL BE MADE AS REQUIRED.
2.) ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE WISCONSIN DNR’S
CONSERVATION PRACTICE STANDARDS. THESE STANDARDS ARE PERIODICALLY UPDATED AND
IT IS THE CONTRACTOR’S RESPONSIBILITY TO OBTAIN AND REFERENCE THE MOST RECENTLY
RELEASED STANDARD.
3.) THIS INFORMATION IS ONLY ONE PART OF THE OVERALL EROSION CONTROL REQUIREMENTS.
ADDITIONAL REQUIREMENTS MAY ALSO BE SHOWN ON THE CONTRACT DRAWINGS AND IN THE
ACCOMPANYING SPECIFICATIONS.
4.) ADDITIONAL EROSION CONTROL MEASURES, AS REQUESTED IN WRITING BY THE STATE OR
LOCAL INSPECTORS, OR THE OWNER’S ENGINEER, SHALL BE INSTALLED WITHIN 24 HOURS.
5.) THE AREA OF EROSIVE LAND EXPOSED TO THE ELEMENTS BY GRUBBING, EXCAVATION,
TRENCHING, BORROW AND FILL OPERATIONS AT ANY ONE TIME SHALL BE MINIMIZED
TO THE MAXIMUM EXTENT PRACTICABLE. FOR ANY DISTURBED AREA THAT REMAINS
INACTIVE FOR GREATER THAN 7 WORKING DAYS, OR WHERE GRADING WORK EXTENDS
BEYOND THE PERMANENT SEEDING DEADLINES, THE SITE MUST BE TREATED WITH TEMPORARY
STABILIZATION MEASURES SUCH AS SOIL TREATMENT, TEMPORARY SEEDING AND/OR MULCHING.
ALL DISTURBED AREAS SHALL BE TREATED WITH PERMANENT STABILIZATION MEASURES WITHIN
3 WORKING DAYS OF FINAL GRADING.
6.) ALL EROSION CONTROL MEASURES AND STRUCTURES SERVING THE SITE MUST BE INSPECTED
AT LEAST WEEKLY OR WITHIN 24 HOURS OF THE TIME 0.5 INCHES OF RAIN HAS OCCURRED.
ALL NECESSARY REPAIR AND MAINTENANCE WILL BE DONE AT THIS INSPECTION TIME.
7.) ALL EROSION CONTROL DEVICES AND/OR STRUCTURES SHALL BE PROPERLY INSTALLED PRIOR
TO CLEARING AND GRUBBING OPERATIONS WITHIN THEIR RESPECTIVE DRAINAGE AREAS.
THESE SHALL BE PROPERLY MAINTAINED FOR MAXIMUM EFFECTIVENESS UNTIL VEGETATION
IS RE-ESTABLISHED.
8.) ALL EROSION CONTROL DEVICES SHALL BE PROPERLY INSTALLED PRIOR TO ANY SOIL DISTURBANCE.
9.) ANY SLOPES STEEPER THAN 3H:1V SHALL BE STAKED WITH EROSION CONTROL FABRIC UNLESS
INDICATED ON THE PLAN.
10.) ALL WASTE AND UNUSED BUILDING MATERIALS (INCLUDING GARBAGE, DEBRIS, CLEANING WASTES, WASTEWATER, TOXIC MATERIALS, OR HAZARDOUS MATERIALS) SHALL BE PROPERLY DISPOSED OF
AND NOT ALLOWED TO BE CARRIED OFF-SITE BY RUNOFF OR WIND.
11.) WIND EROSION SHALL BE KEPT TO A MINIMUM DURING CONSTRUCTION. WATERING, MULCH, OR A TACKING AGENT MAY BE REQUIRED TO PROTECT NEARBY RESIDENCES AND WATER RESOURCES.
12.) CHANNELIZED RUNOFF ENTERING THE PROJECT SITE FROM ADJOINING LANDS SHALL BE
DIVERTED THROUGH NATURALLY OR ARTIFICIALLY EROSION-RESISTANT CONVEYANCES. IF
CHANNELIZED RUNOFF CANNOT BE DIVERTED, SITE BEST MANAGEMENT PRACTICES MUST ACCOUNT
FOR THE ADDITIONAL FLOW RATES AND EROSION POTENTIAL THAT SUCH RUNOFF PRESENTS.
13.) THE CONTRACTOR SHALL TAKE ALL POSSIBLE PRECAUTIONS TO PREVENT SOILS FROM BEING
TRACKED ONTO PUBLIC OR PRIVATE ROADWAYS. PAVED SURFACES ADJACENT TO CONSTRUCTION
SITE VEHICLE ACCESS SHALL BE SWEPT AND/OR SCRAPED (NOT FLUSHED) PERIODICALLY TO
REMOVE SOIL, DIRT, AND/OR DUST.
14.) EROSION CONTROLS SHALL BE INSTALLED ON THE DOWNSTREAM SIDE OF TEMPORARY STOCKPILES.
ANY SOIL STOCKPILE THAT REMAINS FOR MORE THAN 30 DAYS SHALL BE COVERED OR TREATED
WITH STABILIZATION PRACTICES SUCH AS TEMPORARY OR PERMANENT SEEDING AND MULCHING.
ALL STOCK PILES SHALL BE PLACED AT LEAST 75 FEET FROM STREAMS OR WETLANDS.
15.) ADDITIONAL EROSION CONTROL FOR UTILITY CONSTRUCTION (STORM SEWER, SANITARY SEWER, WATER MAIN, ETC.) SHALL INCLUDE THE FOLLOWING:
a. PLACE EXCAVATED TRENCH MATERIAL ON THE HIGH SIDE OF THE TRENCH.
b. BACKFILL, COMPACT, AND STABILIZE THE TRENCH IMMEDIATELY AFTER PIPE CONSTRUCTION.
c. DISCHARGE OF TRENCH WATER OR DEWATERING EFFLUENT MUST BE PROPERLY TREATED
TO REMOVE SEDIMENT IN ACCORDANCE WITH THE WDNR CONSERVATION PRACTICE
STANDARD 1061 - DEWATERING OR A SUBSEQUENT WDNR DEWATERING STANDARD PRIOR
TO DISCHARGE INTO A STORM SEWER, DITCH, DRAINAGEWAY, OR WETLAND OR LAKE.
16.) ALL DRAINAGE CULVERTS, STORM DRAIN INLETS, MANHOLES, OR ANY OTHER EXISTING STRUCTURES
THAT COULD BE DAMAGED BY SEDIMENTATION SHALL BE PROTECTED ACCORDING TO THE VARIOUS
METHODS PROVIDED IN THE PRINTED CONSERVATION PRACTICE STANDARDS.
17.) ANY SOIL EROSION THAT OCCURS AFTER FINAL GRADING AND/OR STABILIZATION MUST BE
REPAIRED AND THE STABILIZATION WORK REDONE.
18.) DURING THE FIRST SIX WEEKS AFTER INITIAL STABILIZATION OF A DISTURBED WATERING OF
ALL NEWLY SEEDED AND MULCHED AREAS SHALL BE PROVIDED WHENEVER 7 DAYS ELAPSE WITHOUT
A RAIN EVENT.
19.) WHEN THE DISTURBED AREA HAS BEEN STABILIZED BY PERMANENT VEGETATION OR OTHER MEANS, TEMPORARY BMP’S SUCH AS SILT FENCES, STRAW BALES, AND SEDIMENT TRAPS SHALL BE REMOVED
AND THESE AREAS STABILIZED.
20.) ALL TEMPORARY BEST MANAGEMENT PRACTICES SHALL BE MAINTAINED UNTIL THE SITE IS STABILIZED.
21.) ALL DISTURBED AREAS SHALL BE PERMANENTLY STABILIZED WITH SEED AND MULCH UNLESS
OTHERWISE SPECIFIED. A MINIMUM OF FOUR INCHES OF TOPSOIL SHALL BE APPLIED TO ALL
AREAS TO BE SEEDED OR SODDED.
GENERAL NOTES:
STAKES DRIVEN FLUSH
WHEN SOIL
CONDITIONS PERMIT
IF REQUIRED, TWO ROWS
MAY BE USED WITH
STAGGERED JOINTS.
EROSION BALES IN DRAINAGE WAY DETAIL
NTS
EROSION BALES ACROSS DITCH BOTTOM SECTION VIEW
SLOPEVAR.
SLOPE
VAR.
N O
M
14" NOM.
BALE
FLOW
BUILD UP
UPSLOPE
SIDE 4"
WITH TRENCH
MATERIAL
EROSION CONTROL CHANNEL
CHANGE & INTERCEPTING EMBANKMENTPLAN VIEW
PLAN VIEW
MIN.
12" MIN.
12"
EROSION
CONTROL
INTERCEPTING
EMBANKMENTCONDITIONS PERMIT
FLUSH WHEN SOIL
STAKES DRIVEN
MIN.
30"
WOOD STAKES
(2 PER BALE) NOMINAL
2"x2"x30" MINIMUM
LENGTH OR
EQUIVALENT.
TOE OF SLOPE
OR DITCHLINE
D
IR
E C
T
IO
F
F L
O W
STAKES DRIVEN
FLUSH WHEN SOIL
CONDITIONS PERMIT
EXISTING
GROUND
OR FILL
FRONT ELEVATION
DETAILS OF CONSTRUCTION, MATERIALS AND WORKMANSHIP NOT SHOWN ON THIS
DRAWING SHALL CONFORM TO THE PERTINENT REQUIREMENTS OF THE SPECIFICATIONS.
BALES SHALL BE PLACED END TO END OR OVERLAPPING AT RIGHT ANGLES TO THE
DIRECTION OF FLOW. BALES SHALL EXTEND FAR ENOUGH UP THE SLOPES TO PREVENT
ERODING AROUND ENDS.
BALES SHALL BE PLACED WITH TWINE OR TIE WIRES PARALLEL TO THE GROUND.
STAKES TO BE BATTERED IN OPPOSITE DIRECTIONS.
BALES SHALL BE EMBEDDED 4 INCHES MINIMUM.
1.
2.
3.
4.
5.
12’ MINIMUM
LIMIT OF DISTURBANCE
VEHICLE TRACKING PAD
NTS
3"-6" WASHED ROCK
12" MIN. THICKNESS
L E
G E
N D
E
R O
S
IO
N C
O N
T R
O L
D E
T A
IL
S
G-2
WATER FOUNTAIN
WATER RISER
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
T
C H
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
100 200 300
EXISTING WAREHOUSE
WELL
(NOT TO SYSTEM)
ELECTRICAL SERVICE
METER POINT
WATER SYSTEM FLUSH POINT
WATER SYSTEM FLUSH POINT
PROPOSED IRRIGATION FIELD
WATER FLUSH POINT
WATER FLUSH POINT
WATER FLUSH POINT
WATER SYSTEM FLUSH POINT
WATER SYSTEM FLUSH POINT
EXISTING WELL AND
NEW RESERVOIR
LOCATION
PROPOSED AEROBIC TREATMENT PLANT
SHEET P-1
SHEET P-2
SHEET P-3
SHEET P-4
SHEET WM-1
SHEET WM-2
G-3
EXISTING COMFORT STATION #1
SEE SHEET PM-1
EXISTING COMFORT STATION #2
SEE SHEET PM-2
EXISTING COMFORT STATION #3
SEE SHEET PM-3
EXISTING COMFORT STATION #4
SEE SHEET PM-4
WATER STORAGE/PUMP BUILDING
TO BE DEMOLISHED
EXISTING LIFT STATION #3
TO BE ABANDONED
EXISTING LIFT STATION #1
TO BE ABANDONED
STEG STATION AT TRAILER DUMP STATION
TTXXXXSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANEEWEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWWWWWWWWWWWWEWWWWWSANX
11832000
SHEET
FILE NO.
EXISTING LIFT STATION #2
TO BE ABANDONED
WATER SERVICE AND SANITARY SEWER LATERAL DETAIL
MATERIAL
EMBEDMENT
LATERAL
SEWER
SANITARY
SOLID SHELF REQUIRED
SERVICE
WATER
M
IN
18" MIN.
MIN.
6" M
IN
SCALE: NONE
GENERAL NOTES:
WATER SERVICES 3 INCHES IN DIAMETER AND LARGER SHALL BE LAID WITH A CLEAR
HORIZONTAL SEPERATION NOT LESS THAN 2 FEET FROM THE SANITARY LATERAL.
1.
3/4 INCH PVC
SCH. 40
STEEL BOLT
STAINLESS
1/4 INCH
CONDUIT,
M
IN
1’-10"
BUTTRESS FOR TEES DETAIL
(SEE NOTE 2)
EXCEEDS 6 INCHES
WHERE DEPTH BELOW PIPE
APPROXIMATE 1:1 SLOPE
MATERIAL
BEDDING
90%%d B
M A
X
A
C
D
SCALE: NONE
SECTION A-A
PLAN
AA
BRANCH
(SEE
NOTE 1)
BRANCH
B.D A
1’-3"6"
B C D
1’-0"
8"
10"
12"
16"
20"
24"
1’-6"
2’-3"
3’-2"
4’-0"
5’-3"
1’-4"
1’-8"
2’-0"
2’-6"
3’-0"
3’-4"
S E
E N
O T
E N
O
S E
E N
O T
E N
O
B.D. = BRANCH DIAMETER
BUTTRESS DIMENSIONS
NOTES:
1.
2.
3.
4.
DIMENSION ’C’ SHOULD BE LARGE ENOUGH TO MAKE ANGLE O GREATER THAN
OR EQUAL TO 45%%d.
CONCRETE SHOULD BEAR ON THIS QUADRANT OF PIPE AT A MINIMUM.
DIMENSION ’D’ SHOULD BE AS LARGE AS POSSIBLE BUT CONCRETE SHOULD NOT INTERFERE
WITH MECHANICAL JOINTS.
5. BUTTRESS TO BE PLACED AGAINST FIRM UNDISTURBED SOIL, OR DISTURBED SOIL
COMPACTED TO 95% OF MODIFIED PROCTOR DENSITY, ASTM D1557.
6.
7. ALL POURED BUTTRESSED FITTINGS SHALL BE WRAPPED IN POLYETHYLENE.
CONCRETE SHALL HAVE A MINIMUM 7-DAY COMPRESSIVE STRENGTH OF 2000 PSI.
BUTTRESS DIMENSIONS ARE BASED ON A SOIL RESISTANCE OF TWO TONS PER SQ. FT.
AND A WATER PRESSURE OF 150 PSI. INFORM THE ENGINEER IF ON-SITE SOIL DOES NOT
MEET THIS CONDITION OR PRESSURES EXCEED 150 PSI.
8. IN ADDITION TO BUTTRESSES, ALL JOINTS SURROUNDING TEES SHALL BE RESTRAINED
WITH WEDGE ACTION RESTRAINING GLANDS.
4" MIN
PIPE INSULATION DETAIL
EXTRUDED POLYSTYRENE
INSULATION (25 PSI)
4 FOOT BY 8 FOOT
2 INCH THICK,
4’-0"
LC 2’-0"
UTILITY SERVICE
UTILITY MAIN OR
SERVICE LINE
MAIN OR
UTILITY
M
IN
D
D
2’ MIN.
D + 12"
INSULATION (25 PSI)
EXTRUDED POLYSTYRENE
2 INCH THICK
SCALE: NONE
STANDARD INSTALLATION
SIDE PROTECTION INSTALLATION
GENERAL NOTES:
1. THE SIDE PROTECTION INSTALLATION SHALL BE USED WHERE FROST WILL PENETRATE
BELOW THE PIPE INVERT.
FLUSH HYDRANT SETTING
G-4
TYPICAL SECTIONS
SCALE: NONE
2" ASPHALT
R 10’ R
12"12"
EXISTING 6" GRAVITY SEWER PIPE
CUT EXISTING 6" SANITARY SEWER SQUARELY
INSTALL 2" PE FORCEMAIN AND
GROUT END OF PIPE
BEND RADIUS OF 2" PE FORCEMAIN ENTERING AND
EXISTING THE GRAVITY SEWER LINE SHALL BEND
NO MORE THAN A 10’ RADIUS
NOTE:
MANHOLE DETAIL
R
L P
S R
A D
IU
S
M
IN
THRUST BLOCK
MIN. RADIUS OF PE
FM 10’.
EX. 6" SAN.
EX. 6" SAN.
PROP. 2" PE FORCEMAIN
MH ABANDONMENT
REMOVE CASTING AND
CONE SECTION MIN.
PERFORATE MH BASE
& BACKFILL WITH SAND
SCALE: NONE
LPS INSTALLATION IN GRAVITY SEWER PIPE
8" CRUSHED AGGREGATE
BASE COURSE
PAVED ROADWAY WALKWAY
5’ WIDE
6" COMPACTED CRUSHED
GRANITE STONE
SLOPE
D E
T A
IL
CONC THRUST BLOCK
ENVELOPE STONE WITH GEOTEXTILE
FABRIC
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
2’-10"
1’-10"
UNDISTURBED SOIL, OR DISTURBED SOIL COMPACTED TO
BUTTRESS FOR PLUGS DETAIL
MATERIAL
BEDDING
D
T R
E N
C H
W
ID
T H
O
A
C
SIDES
FORM
B
6 INCHES.
BELOW PIPE EXCEEDS
SLOPE WHERE DEPTH
APPROXIMATE 1:1
SCALE: NONE
PLAN
ELEVATION
A
1’-6"6"
B
1’-2"
8"
12"
16"
20"
24"
30"
2’-0"
2’-5"
3’-4"
4’-3"
5’-2"
6’-9"
1’-4"
2’-4"
3’-4"
4’-0"
BUTTRESS DIMENSIONS
C DDIA.
S E
E N
O T
E N
O
S E
E N
O T
E N
O
BUTTRESS TO BE PLACED AGAINST FIRM
95% OF MODIFIED PROCTOR DENSITY, ASTM D1557.
NOTES:
1.
2.
3.
4.
5.
6.
DIMENSION ’C’ SHOULD BE LARGE ENOUGH TO
MAKE ANGLE O EQUAL TO OR LARGER THAN 45%%d.
WHERE BUTTRESSES ARE NOT POSSIBLE
BECAUSE OF POOR SOIL CONDITIONS OR LACK
OF ROOM, WEDGE ACTION RESTRAINING GLANDS
7.
DIMENSION ’D’ EQUALS APPROX. I.D. OF PIPE
LESS 2 INCHES. THE CONCRETE SHOULD NOT
INTERFERE WITH THE MECHANICAL JOINTS.
CONCRETE SHALL HAVE A MINIMUM 7-DAY
COMPRESSIVE STRENGTH OF 2000 PSI.
ALL POURED BUTTRESSED FITTINGS SHALL BE
WRAPPED IN POLYETHLENE.
BUTTRESS DIMENSIONS ARE BASED ON A SOIL
RESISTANCE OF TWO TONS PER SQ. FT. AND A
WATER PRESSURE OF 150 PSI. INFORM THE
ENGINEER IF ON-SITE SOIL DOES NOT MEET THIS
CONDITION OR PRESSURES EXCEED 150 PSI.
TYPICAL
BELL END
CAP ON SPIGOT END, PLUG ON
BELL END. (PLUG SHOWN)
SEE
NOTE 1
SHALL BE PERMITTED.
1’-10"
A
1’-0"
1’-2"
1’-7"
2’-4"
2’-10"
3’-3"
45%%d BENDS
PLAN - 22 1/2 %%d BEND
PLAN - 45%%d BEND
BUTTRESS DIMENSIONS
1’-10"
2’-10"
1’-10"
22 1/2 %%d BENDS
APPROX. 1:1 SLOPE WHERE DEPTH
BELOW PIPE EXCEEDS 6 INCHES
PIPE MINIMUM
CONCRETE SHALL
BE IN CONTACT
WITH THIS
QUADRANT OF
BEDDING
MATERIAL
BUTTRESS FOR BENDS DETAIL
A
C
Ø
A
Ø
A
SEE
NOTE 2
SEE
NOTE 2
B
1’-0"6"
D
1’-0"
8"
10"
12"
16"
20"
24"
1’-0"
1’-2"
1’-4"
2’-4"
1’-0"
1’-2"
1’-4"
1’-8"
2’-0"
2’-4"
PIPE
SIZE
1 1 B
1’-0"
1’-4"
1’-7"
2’-6"
3’-3"
4’-0"
90%%d
C
Ø
B
A
SCALE: NONE
PLAN - 90%%d BEND
SECTION A-A
A
A
M A
X
SEE
NOTE 2
C
D D
D
1’-10"
3’-10"
3’-10"
2’-10"
1’-10"
A
B
B
A
B D
1’-2"
1’-6"
2’-3"
3’-4"
3 3D2
1’-4"
2’-3"
2’-8"
5’-0"
6’-4"
90%%d BENDS
1 2 3
NOTES:
1.
DIMENSION C C C SHOULD BE LARGE
ENOUGH TO MAKE ANGLE Ø EQUAL TO
OR LARGER THAN 45%%d.
2.
3.
4.
5.
6.
DIMENSION A A A SHOULD BE AS LARGE
AS POSSIBLE WITHOUT INTERFERRING WITH
THE MECHANICAL JOINT.
BUTTRESS TO BE PLACED AGAINST FIRM
UNDISTURBED SOIL, OR DISTURBED SOIL
COMPACTED TO 95% OF MODIFIED
PROCTOR DENSITY, ASTM D1557.
ALL POURED BUTTRESSED FITTINGS SHALL BE
WRAPPED IN POLYETHYLENE.
CONCRETE SHALL HAVE A MINIMUM 7-DAY
COMPRESSIVE STRENGTH OF 2000 PSI.
DIMENSIONS IN TABLE ARE BASED ON A
WATER PRESSURE OF 150 P.S.I. AND AN
EARTH RESISTANCE OF 2 TONS PER SQ. FT.
INFORM THE ENGINEER IF PRESSURES EXCEED
150 PSI, OR ON-SITE SOIL DOES NOT MEET
THIS CONDITION.
7. IN ADDITION TO BUTTRESS, ALL JOINTS SURROUNDING BENDS SHALL BE
RESTRAINED WITH WEDGE ACTION RESTRAINING GLANDS.
MANHOLE WATERPROOFING DETAIL
SCALE: NONE
GENERAL NOTES:
STAINLESS STEEL
COMPRESSION BANDS
PRECAST, BLOCK, OR BRICK
MANHOLE CORBEL (CONE)
MANHOLE FRAME
& COVER
RUBBER SLEEVE
SEAL EXTENSION
AS REQUIRED
INTERNAL RUBBER SLEEVE FRAME/CHIMNEY SEAL
NON-SHRINK MORTAR
SPREAD ON EXTERIOR OF
ADJUSTMENT RINGS
BLOCK OR BRICK MANHOLES
TO BE BACKPLASTERED
AND SEALED WITH
BITUMINOUS WATERPROOF
COATING
CONCRETE ADJUSTMENT
RINGS AS REQUIRED
FINISHED GRADE
1. THE SEAL SHALL EXTEND FROM THE CASTING TO THE CORBEL (CONE). SEAL EXTENSIONS
SHALL BE USED AS REQUIRED.
2. AN INTERAL ADAPTOR SEAL RING MAY BE USED IN LIEU OF THE RUBBER SLEEVE. THE
INTERNAL ADAPTOR SEAL RING SHALL BE INSTALLED PER MANUFACTURER’S INSTRUCTIONS.
RUBBER SLEEVE
MANHOLE COVER
MANHOLE FRAME
EXTERNAL RUBBER SLEEVE FRAME/CHIMNEY SEAL
FINISHED GRADE
GENERAL NOTE:
THE SEAL SHALL EXTEND FROM THE CASTING TO THE CORBEL
(CONE). SEAL EXTENSIONS SHALL BE USED AS REQUIRED.
STAINLESS STEEL
COMPRESSION BAND
AS RECOMMENDED
BY MANUFACTURER
CONCRETE ADJUSTMENT
RINGS AS REQUIRED
FINISHED GRADE
2 LAYERS OF 4 MIL.
PLASTIC SHEET AS
SPECIFIED.
CONCRETE ADJUSTMENT
RINGS AS REQUIRED
ELASTOMERIC FRAME/CHIMNEY SEAL
THE BOND BREAKER TAPE IS TO PREVENT THE SEALER FROM BONDING TO THE EDGE OF
THE FLANGE OF THE MH FRAME AND THE UPPER 1-1/2 INCHES OF ADJUSTING RING OR
CONE. IF THE EDGE OF FLANGE IS NOT FLUSH WITH ADJUSTING RING OR CONE, APPLY
ADDITIONAL TAPE AS REQUIRED TO PREVENT SUCH BONDING.
MANHOLE FRAME & COVER
MANHOLE CONE SECTION
2 INCH OR 3 INCH BOND
BREAKER TAPE. CENTER
OVER JOINT BETWEEN
MANHOLE FRAME AND
ADJUSTING RINGS OR
CONE SECTION AS
APPLICABLE. SEE NOTE.
ELASTOMERIC
WATERPROOFING
SEALER.
SCALE: NONE
PRECAST REINFORCED CONCRETE MANHOLE DETAIL
ABOVE THE MANHOLE INVERT.
90%%d
BEND
TEE
4"
PRECAST
REINFORCED
CONCRETE
ECCENTRIC
OR FLAT TOP
(SEE "GENERAL
NOTES")
CLASS A
CONCRETE
D
#4 BARS
12" C-C TO
12’ DEPTH
6" C-C OVER
12’ TO 25’ DEPTH
2’-0"
4" MIN.
W
SPLIT PIPE
OR FORM
CONCRETE
TO FIT
PRECAST
REINFORCED
CONCRETE
RISERS
MIN. SLOPE
1 INCH/FT.
6 INCHES
MINIMUM
COMPACTED
GRANULAR
BEDDING
CONCRETE
ENCASEMENT
GENERAL NOTES:
PRECAST REINFORCED CONCRETE RISERS MAY BE PLACED WITH TONGUE UP OR DOWN.
ALL PRECAST INLET UNITS SHALL CONFORM TO THE PERTINENT REQUIREMENTS OF AASHTO
DESIGNATION M 199.
PRECAST REINFORCED BASES SHALL BE PLACED ON A BED OF MATERIAL AT LEAST
6 INCHES IN DEPTH, WHICH MEETS THE REQUIREMENTS FOR GRANULAR BACKFILL.
THIS BEDDING SHALL BE COMPACTED AND PROVIDE UNIFORM SUPPORT FOR THE ENTIRE
AREA OF THE BASE.
DETAILS OF CONSTRUCTION, MATERIALS AND WORKMANSHIP NOT SHOWN ON THIS DRAWING
SHALL CONFORM TO THE PERTINENT REQUIREMENTS OF THE STANDARD SPECIFICATIONS
AND THE APPLICABLE SPECIAL CONDITIONS.
DROP CONNECTIONS SHALL BE USED WHEN THE PIPE INVERT IS MORE THAN 2 FEET
DETAILED DRAWINGS FOR PROPOSED ALTERNATE DESIGNS FOR UNDERGROUND STRUCTURES
SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PROVIDING THAT SUCH ALTERNATE
DESIGNS MAKE PROVISION FOR EQUIVALENT CAPACITY AND STRENGTH.
1.
2.
3.
4.
5.
6.
7.
ECCENTRIC CONE TOPS SHALL BE USED ON ALL STRUCTURES 5 FEET OR GREATER
IN DEPTH, AND FLAT TOPS SHALL BE USED ONLY ON STRUCTURES LESS THAN 5 FEET
IN DEPTH, UNLESS DIRECTED BY THE ENGINEER.
TYPE W(FEET)
M
IN
SECTION A-A
PLAN
DROP ASSEMBLY DETAIL
A A
8. PRECAST STRUCTURE MANWAY CLEAR OPENING SHALL MATCH CASTING - REFER TO STANDARD SPECIFICATION
DIVISION 33 AND THE APPLICABLE SPECIAL CONDITIONS.
- OPENING SHALL BE 24" FOR R-1550 CASTINGS
- OPENING SHALL BE 27" FOR R-1642 CASTINGS
SCALE: NONE
SCALE: NONE
5’ PRECAST MANHOLE
SCALE: NONE
BREATHER ASSEMBLY
4" PVC
AIR RELEASE VALVE TOP
4" INCREASER, PVC
NOTE:
THE PIPE, BALL VALVE AND
INCREASER SHALL MATCH THE OUTLET
DIAMETER FROM THE PROPOSED AIR
RELEASE VALVE.
PVC TEE
PVC PIPE
PVC BALL VALVE
PVC PIPE
A
D
NOTE:
CONTRACTOR TO PROVIDE SUMP
IN BOTTOM OF MANHOLE.
4" DUCTILE IRON AND PAINTED
MH VENT W/ S.S. SCREEN.
SEE PLANS FOR LOCATIONS
PROVIDE AND INSTALL PEACEMAKER
VENT BY SYNCO SYSTEMS OR EQUAL
PROVIDE WATERTIGHT
SEAL (TYP.)
CONC.
BLOCKING
(TYP.)
6"x6"x8’ MARKER POST
2" BALL
VALVE
PE (IP)
THREADED
ADAPTER
MANHOLE FRAME & LID
NEENAH R-6005
OR EQUAL
NEENAH R-1550 CASTING
2" BALL
VALVE
PE (IP)
THREADED
ADAPTER
MANHOLE FRAME & LID
NEENAH R-6005
OR EQUAL
TYPE 2 MANHOLE
BREATHER ASSEMBLY
SEE DETAIL BELOW
5’ MANHOLE
1" COMBINATION AIR VALVE
BALL VALVE
M
IN
HDPE FLANGE
ADAPTER
PROVIDE WATERTIGHT
SEAL (TYP.)
TEE W/ BLIND FLANGE W/ NPT TAP
7" GROUT, SLOPE TO SUMP1’-9" MIN. NO. 2 WASHED
STONE ENVELOPED IN
GEOFABRIC, TYPE SAS
UNIFLANGE
6’ MANHOLE
BASE
PIPE SUPPORT
(2 PLACES)
2" PE FORCEMAIN
TYPICAL PLUG VALVE
SEE SPECIFICATIONS
ARCH
TYPE
BASE
THRUST
BLOCKING
SECTION - AIR VALVE MANHOLE W/ DUAL FLUSH CONNECTION
2’ 2’ 2’
GRADE TO DRAIN
MANHOLE FRAME & LID
NEENAH R 6005
OR EQUAL
MANHOLE FRAME & LID
NEENAH R 6005
OR EQUAL
SIZE TO FIT
14-3/4"
DIA.
14-3/4"
DIA.
4" VALVE BOX
TYLER #664-S
OR EQUAL
TROWEL SMOOTH
W/ 6X6-W1.4XW1.4
WIRE MESH
4" CONC.
NEENAH R-1550 CASTING AND LID
LOCKING COVER
(TYP.)
(MIP) THREADED PLUG
(TYP.)
PLAN - AIR VALVE MANHOLE W/ DUAL FLUSH CONNECTION
G-5
D E
T A
IL
N
O
D A
T E
R E
V
IS
IO
N
B Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
CC
G-6
24"
WATER FOUNTAIN DRAIN DETAIL
WATERMAIN DRAIN DETAIL
24"
DUAL FLUSH CONNECTION
TERMINAL FLUSH CONNECTION
WATER RISER SERVICE
WATER LATERAL CONNECTION
M
IN
12"12"
SCALE: NONE
EX. 6" SAN. EX. 6" SAN.
REMOVE GRAVITY SEWER
SECTIONS AS NECESSARY
TO INSTALL TEE FITTING
2" PE LPS
MIN. MIN.
2" PE LATERAL
FROM STEP STATION
THRUST BLOCK
FUSED 2"X2" TEE
GROUT END OF
PIPE (TYP.)
E
T A
IL
LPS TEE CONNECTION TO MAIN
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
4’-8"
1’-0" 9"
M
IN
2 "
M
I N
C
O V
E R
(MIP) THREADED PLUG
(IP) THREADED ADAPTOR
M
I N
INVERT ELEVATION
RIM ELEVATION
14 3/4"
DIA.
1’-9 1/16"1’-3 9/16" 1’-7 3/8"
GRANULAR
FILL
10" PVC
SEE PLAN &
PROFILE SHEETS
ROADWAY BOX
SEE SPECIFICATIONS
4 1/4"
MIN.
45%%d
FTGS.
SCALE: NONE
MATCH EXISTING
GRADE
WIRE MESH
W/ 6x6-W1.4xW1.4
TROWEL SMOOTH
MANHOLE FRAME & LID
NEENAH R-6005
OR EQUAL
4" VALVE BOX
TYLER #664-S
OR EQUAL
2" BALL VALVE SEE SPEC
LOCKING COVER, TYP.
TYPICAL
PLUG VALVE,
SEE SPECIFICATIONS
THRUST BLOCKS, TYP.
OR EQUALWIRE MESH
1’-8 5/8 "
2" BALL VALVE
MATCH LPSM.
DIMENSIONS TO
TEE
THREADED
PE (IP)
ADAPTOR
BLOCKING
CONC.
SLAB
4" CONC.
NOM.
M
I N
C
O V
E R
4-1/4"
SCALE: NONE
THRUST BLOCKS, TYP.
MIN.
TYPICAL
SEE SPECIFICATIONS
PLUG VALVE
2"
TYPE
ARCH
BASE
2"
M
IN
M
IN
1’-6 3/8 "
(10.75)
10" PVC
1’-6 3/8 "
6’-6"
FILL
GRANULAR
1’-8 5/8 "
DIA.
14-3/4"
NEENAH R-6005
MANHOLE FRAME & LID
SIZE TO
FIT
TROWEL SMOOTH
W/ 6x6-W1.4xW1.4
OR EQUAL
TYLER #664-S
4" VALVE BOX
14-3/4"
PROFILE SHEETS
SEE PLAN &
INVERT ELEVATION
GRADE
MATCH EXISTING
RIM ELEVATION
LOCKING COVER, TYP.
LPSM - SEE PLAN & PROFILE
DIA.
SHEETS FOR DIA.
(MIP) THREADED PLUG
.5
TYPE "K" COPPER CONFORMING TO AWWA C800
SERVICE PIPE(DIA AS SHOWN ON PLANS)
WATER MAIN
SMITH-BLAIR
SERVICE SADDLE OR EQUAL
CONCRETE BLOCK
N.T.S.
.0
’M
IN
3/4" G.I.
4"X4" TREATED
SUPPORT POST
1" TYPE K COPPER
SERVICE LATERAL
SWING JOINT
TRANSITION FROM
1" COPPER TO 3
" G. I.
CURB STOP & BOX
W/EXTENSION ROD,
MINNEAPOLIS PATTERN
6.0’ BURY - SIZE SAME
AS SERVICE LATERAL DIA.
NOTE: INSTALL AT EACH CAMP HOST SITE
N.T.S.
SCALE: NONE
AIR GAP
2X PIPE DIA.
SQUARE
GRAVEL
SUMP
STAINLESS
STEEL SCREEN
M
IN
1 1/4" G.I. DRAIN
PITCHED TO SUMP
VARIABLE - POSITION DRAIN
OUTLET & GRAVEL SUMP
IN UNTRAVELED WAY AS
DIRECTED BY PARK PERSONNEL
18"
WATER FOUNTAIN BASE
& SPLASH BLOCK
36" X 36" CONCRETE SLAB
1" COPPER
WATER SERVICE
SCALE: NONE
VALVE AND PIPE SIZE AND
MATERIALS SAME AS WATERMAIN
SQUARE
GRAVEL
SUMP
STAINLESS
STEEL SCREEN
M
IN
LAY DRAIN PIPE TO
PITCH TOWARDS SUMP
AIR GAP
2X PIPE DIA.
MINIMUM
M A
X
M A
X
8" SCH 40
PCV VALVE
BOX
18"
WATER FOUNTAIN
SEE PLUMBING SPECIFICATION
34" HOSE BIBB W/NON-REMOVEALBE VACUUM BREAKER
NIDEL 37HD2 OR EQUAL
GEOTEXTILE FABRIC
ALL 5 SIDES
M in
3/4" WOODFORD MANUFACTURING MODEL 40HT-LH SPIGOT
W/THREADED END & NON-REMOVEABLE
VACUUM BREAKER NIDEL 37 HD2 OR EQUAL
FASTEN TO POST SECURELY WITH
STAINLESS STEEL PIPE STRAPS
SANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANWWWWWWEEEEEEWWEEEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWWWWWWWWWWWWSANW
.6
.9
.4
.5
.9
.0
.9
.8
.1
.2
.1
.2
.3
.3
.1
.2
.4
.3
.1
.2
.5
.6
.3
.2
.1
.3
.7
.6
.2
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00
P L
A N
P
R O
F
IL
E N
O
D A
T E
R E
V
IS
IO
N
B Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
25 50 100
ELEV.
BENCHMARK TABLE
BM. NO. STATION DESCRIPTION
CAUTION
ELECTRIC
RIM = 1272.88
SANITARY MANHOLE, TYPE 1
W/CASTING, R1550
STA. 2+00, CL
I.E.= 1267.30, (NW)
I.E.= 1267.30, (SE)
0+03, 28’ L.
4+21, 32’ L.
15+43, 2’ L.
1272.74
1269.25
1273.65
RIM = 1269.12
SANITARY MANHOLE, TYPE 1
W/CASTING, R1550
STA. 4+01.03
I.E.= 1264.58, (N)
I.E.= 1264.58, (SE)
TOP OF CONC., SE CORNER
TOP OF CONC., E CORNER
TOP OF CONC., W CORNER
SANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANXSANSANSANSANEEEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSANSANSANWSANW
.2
.3
.2
.7
.2
.5
.5
.7
.0
.2
.1
.9
.6
.6
.6
.8
.6
.8
.7
.3
.9
.8
.9
.2
.6
.3
.9
.6
.6
.9
14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50
P L
A N
P
R O
F
IL
E N
O
D A
T E
R E
V
IS
IO
N
B Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
CAUTION
ELECTRIC
EXISTING GROUND OVER SANITARY SEWER
1-4" VALVE AND BOX
1-4" VALVE AND BOX
7.0’ MIN. COVER
WATERMAIN DRAIN LOCATION
DEPRESS WATER MAIN TO
DRAIN AT THIS LOCATION
TOP OF PIPE EL. 1261.5
8’ MIN. SEP.
BM# 5876
RIM = 1272.4
SANITARY MANHOLE, TYPE 2
W/CASTING, R1550
STA. 18+65
I.E.= 1267.4
AIR VALVE MANHOLE W/ DUAL FLUSH CONNECTION
STEP STATION #3
P-2
EXISITNG LIFT STATION #1
TO BE ABANDONED
236 L.F. 4" PE WATERMAIN
CAUTION
ELECTRIC
TOP OF 1400 L.F. 4" PE WATERMAIN
1-COUPLER
1-CAP
WATERMAIN DRAIN POINT
GRAVITY DRAIN
SEE DETAIL SHEET G-6
ABANDON EXISTING
MANHOLE
(TYP.)
EXISITNG LIFT STATION #1
TO BE ABANDONED
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
ABANDON EXISTING
MANHOLE
(TYP.)
STEP STATION #3
INV. EL. 1269.00
SEE SHEET PM-4 FOR DETAIL
DUAL FLUSH CONNECTION
FORCEMAIN DRAIN
SEE DETAIL SHEET G-6
SSSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANEEEEEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWSANWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
.6
.9
.9
.8
.5
.0
.3
.7
.4
.4
.1
.9
.7
.5
.2
.9
.2
.1
.9
.2
.0
.3
.6
.8
.1
.8
.7
.0
.6
.5
28+00 28+50 29+00 29+50 30+00 30+50 31+00 31+50 32+00 32+50 33+00 33+50 34+00 34+50 35+00 35+50 36+00 36+50 37+00 37+50 38+00 38+50 39+00 39+50 40+00 40+50 41+00 41+50 42+00 42+50
P L
A N
P
R O
F
IL
E N
O
D A
T E
R E
V
IS
IO
N
B Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
EXISITING GROUND OVER SANITARY SEWER
EXISITING GROUND OVER SANITARY WATERMAIN
1-4" VALVE AND BOX
BM#1760
BM#1607
BM#1449
8’ MIN. SEP.
7.0’ MIN. COVER
WATERMAIN DRAIN LOCATION
DEPRESS WATER MAIN TO
DRAIN AT THIS LOCATION
TOP OF PIPE EL. 1268
CAUTION
ELECTRIC
RIM = 1285.6
SANITARY MANHOLE, TYPE 2
W/CASTING, R1550
STA. 33+92
I.E.= 1281.6
P-3
AIR VALVE MANHOLE
W/ DUAL FLUSH CONNECTION
DISCONNECT AND PLUG
EXISTING 2" AND 6"
WATERMAINS
1-4" VALVE AND BOX
EXISTING LIFT STATION #2
TO BE ABANDONED
ABANDON
EXISTING SANITARY
MANHOLE
(TYP.)
MAINTAIN HIGH POINT
AT MANHOLE
NOTES:
1.
2.
1-FLUSH HYDRANT
1-4"X2" TEE
1-ADAPTER PE TO IP
5 L.F. 2" PE WATERMAIN
1-4"X2" TEE
1-FLUSH HYDRANT
1-ADAPTER PE TO IP
5 L.F. 2" PE WATERMAIN
PLUG BARREL DRAIN
WATERMAIN DRAIN POINT
SUCTION REQ’D.
REMOVE CAP & GROUT AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
EXISTING WATER
STORAGE TANK AND PUMP BLDG.
TO BE ABANDONED
SEE DM-1 SHEET
REMOVE CAP & GROUT AS PER SPECIFICATIONS
EXISTING LIFT STATION #2
TO BE ABANDONED
5’ WIDE X 10 L.F.
CRUSHED GRANITE
WALKWAY
15 L.F. 1" COPPER WATER SERVICE
1-WATER FOUNTAIN
1-1" CURB STOP
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
73 L.F. 1" COPPER WATER SERVICE
1-WATER RISER
1-1" CURB STOP
5 L.F. 1" COPPER WATER SERVICE
1-WATER RISER
1-1" CURB STOP
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
SSTTTTTTXXXXXXXXXXXXXXXTSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWEEEE
.6
.5
.2
.7
.5
.6
.0
.4
.1
.3
.3
.0
.1
.3
.6
.0
.1
.6
.6
42+00 42+50 43+00 43+50 44+00 44+50 45+00 45+50 46+00 46+50 47+00 47+50 48+00 48+50 49+00 49+50 50+00 50+50 51+00 51+50 52+00 52+50 53+00 53+50 54+00 54+50 55+00 55+50 56+00 56+50
P L
A N
P
R O
F
IL
E N
O
D A
T E
R E
V
IS
IO
N
B Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
SEE WWTF PLAN SITE
FOR CONTINUATION OF WATERMAIN
EXISTING GROUND OVER SANITARY SEWER
REMOVE MANHOLE
NOTES:
1.
2.
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
SANSANSANSANSANSANSANSANSANSANSANSANWWWWWWWWWWWWWWEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWW
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
SANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANEEEEEEEEEEEEEEWWWWWWEEEEEEEEEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSAN
SANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSANSANSANWWWW
O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
402010
1-WATER RISER
STEP STATION #2
50 L.F. 2" COPPER WATER SERVICE
CONNECT TO EXISTING
10 L.F. 2" PE SANITARY SEWER
HOST SITE S46
NOTE:
WHEREVER NEW UTILITY LINES CROSS EX. WATER LINES
ABANDON AS PER SPECIFICATIONS
1.
REMOVE CAP & GROUT AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
1-4" VALVE AND BOX
EX. WATER SERVICE TO REMAIN
PAVEMENT
RESTORATION
SEE DETAIL SHEET G-4
15 L.F. 4" PVC SANITARY SEWER LATERAL @2.00%
CONNECT TO EXISTING
PROVIDE BENDS AS NECESSARY TO REALIGN
PIPING
EX. C.O. & CAMP SITE LATERAL TO REMAIN
1-WATER RISER
1-1" CURBSTOP
5 L.F. 1" COPPER WATER SERVICE
1-2" PE TEE - SEE DETAIL SHEET G-6
PAVEMENT
RESTORATION
SANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANSANXEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSANSANSANSANSANSANSANWW
O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
10 20 40
STEP STATION #3
50 L.F. 2" PE SANITARY SEWER
PROP. 115 L.F. 2" COPPER WATER SERVICE
MAKE CONNECTION TO EXISTING
HOST SITE #58
NOTE:
WHEREVER NEW UTILITY LINES CROSS EX. WATER LINES
ABANDON AS PER SPECIFICATIONS
1.
REMOVE CAP & GROUT AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
REMOVE AND ABANDON AS PER SPECIFICATIONS
REMOVE AND ABANDON
AS PER SPECIFICATIONS
1-4" VALVE AND BOX
1-2" PE TEE - SEE DETAIL SHEET
15 L.F. 4" PVC SANITARY SEWER LATERAL @2.00%
CONNECT TO EXISTING
PROVIDE BENDS AS NECESSARY TO REALIGN
PIPING EX. C.O. & CAMP SITE LATERAL TO REMAIN
EXISTING WATER SERVICE
TO REMAIN
REMOVE AND ABANDON AS PER SPECIFICATIONS
PAVEMENT RESTORATION
SEE DETAIL SHEET G-4
1-WATER RISER
1-" CURBSTOP
5 L.F. 1" COPPER WATER SERVICE
1-WATER RISER
CONNECT TO EX.
WATER SERVICE
INLET BAFFLE
EXCAVATION AREA
BACKFILL WITH GRANULAR MATERIAL
4" PVC SUPPORT PIPE
4" PVC SUPPORT PIPE
M
IN
6" PVC INLET
VOLUME = 3000 GAL
VOLUME = 1800 GAL
24" ACCESS RISER
WITH CONCRETE COVER 24" ACCESS RISER
WITH CONCRETE COVER
NOTE:
TERMINATE ALL COVERS 6" ABOVE FINISHED GRADE
AND PROVIDE LOCKING DEVICE FOR COVER AND
WARNING LABEL PER COMM 84.25(8).
EXTEND 2" INSULATION (4X8 SHEETS)
4 FEET BEYOND COVER OF TANK
3" MIN COMPACTED GRANULAR BACKFILL
1-12" CONDUIT
1-12" CONDUIT
ALARM
LAG ON
ON
OFF
FLOATS
ALARM = 1261.50
LAG ON = 1261.00
ON = 1260.50
OFF = 1260.00
ITT CENTRIPRO GUIDE RAIL
MODEL A10-20 OR EQUAL
WITH QUICK DISCONNECT
4" PVC SCHEDULE 40
SUPPORT PIPE
EXTEND 3 FEET INTO
UNDISTURBED SOIL
4" PVC SCHEDULE 40 VENT
WITH APPROVED BOLT ON
VENTED CAP
1264.50
2" INSULATION, INSTALL 6" ABOVE TANK
FLOAT ASSEMBLY
NOTE:
FLOAT ASSEMBLY SHALL BE 1" SCHEDULE 40 PVC
ATTACHED TO THE SIDE WALL OF RISER WITH STAINLESS
STEEL FASTENERS. FLOAT ASSEMBLYSHALL BE REMOVABLE
FOR FLOAT ADJUSTMENT WITHOUT ENTERING TANK.
EFFLUENT FILTER
SANITEE ST818
OR EQUAL
2" CHECK VALVE
1 PER PUMP REQ’D
S T
E P
S T
A T
IO
N
N O
PM-5
STEP STATION NO. 1
N.T.S.
PM-5
PM-5
POST MOUNTED SERVICE PANEL
SEE TYPICAL THIS SHEET
PM-5 N.T.S.
STEP STATION NO. 1 SECTION
2" PVC LONG SWEEP 90%%d
2" PVC LONG SWEEP 90%%d
TRANSITION COUPLING
2" PVC TO 2" PE PIPE
2" PE PRESSURE SEWER
2" PVC TEE
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" FERNCO COUPLING
CONNECT TO MANHOLE
SEE P-1 PLAN SHEET
FOR HOOKUP ELEVATION
6" SCHEDULE 40 PVC
WIESER TANK
MODEL W3000/1800
OR EQUAL
PUMP CONTROL PANEL
WATERTIGHT STAINLESS STEEL
M
IN
M
IN
2’ X 2’ MIN. SIZE
TO WETWELL
TYPE NEMA 4X VENTED
FIBERGLASS ENVIRONMENT
ISOLATION BOX
12" X 18" MIN.
PM-5
TYPICAL POST MOUNT SERVICE PANEL
N.T.S.
120 V CONVENIENCE OUTLET
FROM TRANSFORMER
DIRECT BURY CABLE
TREATED 4X4 POST
WITH TREATED PLYWOOD
WITH A 45%%d BEVELED TOPELECTRICAL SERVICE BREAKER
PANEL UTILITY RATED W/LOCK KIT
APPROVED. INSTALL CONDUIT
FROM PANEL TO BELOW GRADE
TO RUN CABLE FROM TRANSFORMER
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
INLET BAFFLE
EXCAVATION AREA
BACKFILL WITH GRANULAR MATERIAL
4" PVC SUPPORT PIPE
4" PVC SUPPORT PIPE
M
IN
4" PVC INLET
VOLUME = 1585 GAL
24" ACCESS RISER
WITH CONCRETE COVER 24" ACCESS RISER
WITH CONCRETE COVER
NOTE:
TERMINATE ALL COVERS 6" ABOVE FINISHED GRADE
AND PROVIDE LOCKING DEVICE FOR COVER AND
WARNING LABEL PER COMM 84.25(8).
EXTEND 2" INSULATION (4X8 SHEETS)
4 FEET BEYOND COVER OF TANK
3" MIN COMPACTED GRANULAR BACKFILL
1-12" CONDUIT
1-12" CONDUIT
ALARM
LAG ON
ON
OFF
FLOATS
ALARM = 1268.00
LAG ON = 1267.70
ON = 1267.40
OFF = 1266.90
ITT CENTRIPRO GUIDE RAIL
MODEL A10-20 OR EQUAL
WITH QUICK DISCONNECT
4" PVC SCHEDULE 40
SUPPORT PIPE
EXTEND 3 FEET INTO
UNDISTURBED SOIL
4" PVC SCHEDULE 40 VENT
WITH APPROVED BOLT ON
VENTED CAP
1269.00
2" INSULATION, INSTALL 6" ABOVE TANK
FLOAT ASSEMBLY
NOTE:
FLOAT ASSEMBLY SHALL BE 1" SCHEDULE 40 PVC
ATTACHED TO THE SIDE WALL OF RISER WITH STAINLESS
STEEL FASTENERS. FLOAT ASSEMBLYSHALL BE REMOVABLE
FOR FLOAT ADJUSTMENT WITHOUT ENTERING TANK.
EFFLUENT FILTER
SANITEE ST818
OR EQUAL
2" CHECK VALVE
1 PER PUMP REQ’D
S T
E P
S T
A T
IO
N
N O
PM-6
STEP STATION NO. 2
N.T.S.
PM-6
PM-6
POST MOUNTED SERVICE PANEL
SEE TYPICAL THIS SHEET
PM-6 N.T.S.
STEP STATION NO. 2 SECTION
2" PVC LONG SWEEP 90%%d
2" PVC LONG SWEEP 90%%d
2" PE PRESSURE SEWER
2" PVC TEE
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" FERNCO COUPLING
VOLUME = 950 GAL
CONNECT TO EXISTING BUILDING LATERAL
FROM COMFORT STATION #3.
USE NO MORE THAN THREE
6"- 45%%d BENDS, NO 90%%d ALLOWED
4" SCHEDULE 40 PVC
1273.40%%P
TRANSITION COUPLING
2" PVC TO 2" PE PIPE
PUMP CONTROL PANEL
WATERTIGHT STAINLESS STEEL
M
IN
M
IN
2’ X 2’ MIN. SIZE
TO WETWELL
TYPE NEMA 4X VENTED
FIBERGLASS ENVIRONMENT
ISOLATION BOX
12" X 18" MIN.
PM-6
TYPICAL POST MOUNT SERVICE PANEL
N.T.S.
120 V CONVENIENCE OUTLET
FROM TRANSFORMER
DIRECT BURY CABLE
TREATED 4X4 POST
WITH TREATED PLYWOOD
WITH A 45%%d BEVELED TOPELECTRICAL SERVICE BREAKER
PANEL UTILITY RATED W/LOCK KIT
APPROVED. INSTALL CONDUIT
FROM PANEL TO BELOW GRADE
TO RUN CABLE FROM TRANSFORMER
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
WIESER TANK
MODEL WPL1585/950
OR EQUAL
INLET BAFFLE
EXCAVATION AREA
BACKFILL WITH GRANULAR MATERIAL
4" PVC SUPPORT PIPE
4" PVC SUPPORT PIPE
M
IN
4" PVC INLET
VOLUME = 1585 GAL
24" ACCESS RISER
WITH CONCRETE COVER 24" ACCESS RISER
WITH CONCRETE COVER
NOTE:
TERMINATE ALL COVERS 6" ABOVE FINISHED GRADE
AND PROVIDE LOCKING DEVICE FOR COVER AND
WARNING LABEL PER COMM 84.25(8).
EXTEND 2" INSULATION (4X8 SHEETS)
4 FEET BEYOND COVER OF TANK
3" MIN COMPACTED GRANULAR BACKFILL
1-12" CONDUIT
1-12" CONDUIT
ALARM
LAG ON
ON
OFF
FLOATS
ALARM = 1268.00
LAG ON = 1267.70
ON = 1267.40
OFF = 1266.90
ITT CENTRIPRO GUIDE RAIL
MODEL A10-20 OR EQUAL
WITH QUICK DISCONNECT
4" PVC SCHEDULE 40
SUPPORT PIPE
EXTEND 3 FEET INTO
UNDISTURBED SOIL
4" PVC SCHEDULE 40 VENT
WITH APPROVED BOLT ON
VENTED CAP
1269.00
2" INSULATION, INSTALL 6" ABOVE TANK
FLOAT ASSEMBLY
NOTE:
FLOAT ASSEMBLY SHALL BE 1" SCHEDULE 40 PVC
ATTACHED TO THE SIDE WALL OF RISER WITH STAINLESS
STEEL FASTENERS. FLOAT ASSEMBLYSHALL BE REMOVABLE
FOR FLOAT ADJUSTMENT WITHOUT ENTERING TANK.
EFFLUENT FILTER
SANITEE ST818
OR EQUAL
2" CHECK VALVE
1 PER PUMP REQ’D
S T
E P
S T
A T
IO
N
N O
PM-7
STEP STATION NO. 3
N.T.S.
PM-7
PM-7
POST MOUNTED SERVICE PANEL
SEE TYPICAL THIS SHEET
PM-7 N.T.S.
STEP STATION NO. 3 SECTION
2" PVC LONG SWEEP 90%%d
2" PVC LONG SWEEP 90%%d
TRANSITION COUPLING
2" PVC TO 2" PE PIPE
2" PE PRESSURE SEWER
2" PVC TEE
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" GATE VALVE W/ BOX
WITH SQUARE OPERATING
NUT EXTENSION ROD
2" FERNCO COUPLING
VOLUME = 950 GAL
CONNECT TO EXISTING BUILDING LATERAL
FROM COMFORT STATION #4.
USE NO MORE THAN THREE
6"- 45%%d BENDS, NO 90%%d ALLOWED
4" SCHEDULE 40 PVC
1273.40%%P
WIESER TANK
MODEL WPL1585/950
OR EQUAL
PUMP CONTROL PANEL
WATERTIGHT STAINLESS STEEL
M
IN
M
IN
2’ X 2’ MIN. SIZE
TO WETWELL
TYPE NEMA 4X VENTED
FIBERGLASS ENVIRONMENT
ISOLATION BOX
12" X 18" MIN.
PM-7
TYPICAL POST MOUNT SERVICE PANEL
N.T.S.
120 V CONVENIENCE OUTLET
FROM TRANSFORMER
DIRECT BURY CABLE
TREATED 4X4 POST
WITH TREATED PLYWOOD
WITH A 45%%d BEVELED TOPELECTRICAL SERVICE BREAKER
PANEL UTILITY RATED W/LOCK KIT
APPROVED. INSTALL CONDUIT
FROM PANEL TO BELOW GRADE
TO RUN CABLE FROM TRANSFORMER
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
1279.00
CONNECT TO SEWER LATERAL FROM
DUMP AND FISH CLEANING STATION
6" PVC SCHEDULE 40
3" MIN COMPACTED GRANULAR FILL UNDER TANK
24" DIA OPENING WITH CONCRETE LID
WITH WARNING LABEL & CHAINS WITH PADLOCK
TYPICAL ALL COVER OPENINGS
4" PVC SCHEDULE 40 OBSERVATION OPENING
WITH VENT CAP, SECURE TO PIPE
2" INSULATION (4X8 SHEETS) 6" ABOVE TANK
EXTEND 4’ MIN OUTSIDE TANK COVER
6" PVC SCHEDULE 40 OUTLET6" PVC SCHEDULE 40 INLET
1284.00%%P
WIESER TANK
MODEL WLP 1585/950
OR EQUAL
POLYETHYLENE BAFFLE
EFFLUENT FILTER
SANITEE ST 818
OR EQUAL
EFFLUENT FILTER
SANITEE ST 818
OR EQUAL
S T
E G
S T
A T
IO
N
PM-8
PM-8 N.T.S.
N.T.S.
PM-8
STEG STATION PLAN
PROVIDE 20 L.F. 6" PVC TO CONNECT TO NEW
GRAVITY SEWER LINE, SEE SHEET P-4
1279.75
EXCAVATE A MIN OF 4 FEET AROUND TANK
STEG STATION SECTION
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
NEW MANHOLE LOCATION IS 24’ FEET SW
OF EXISTING MANHOLE
SEE COLLECTION SYSTEM PLANS
REMOVE EXISTING FENCE
P1
RIM = 1271.50
SANITARY MANHOLE, TYPE 1
STA. 0+44.55
I.E.= 1266.00, (NE)
I.E.= 1266.10, (W)
IRRIGATION PUMP TANK
12’ WIDE DRIVEWAY
TWIN 12’ GATES
185.00’
APPROXIMATELY 59 LF 4" SAN LATERAL
10 20 40
E
CONCRETE SLAB TO BE REMOVED
INSTALL 2" FLUSHING HYDRANT
REMOVE EXISTING ANCHOR PLUGS (4)
AND CABLES FOR LAGOON AERATOR
BEFORE DEMOLITION OF LAGOON
58 LF 8" PVC
SAN SEWER
@ 0.64%
70 LF OF1" PE
WATER SERVICE
INSTALL SILT FENCE AS SHOWN BEFORE GRADING OPERATION BEGINS
174 LF 8" PVC SAN SEWER @ 0.57%
EEE
12’ GATE
SEE PLAN AND PROFILE SHEETS FOR CONTINUATION
SEE PLAN AND PROFILE SHEETS FOR CONTINUATION
CONNECT TO 4" PE
2" X 4" PE REDUCER
6’ BURY MIN.
4" PE WATERMAIN, 6’ MIN. BURY
AEROBIC TREATMENT UNIT
AEROBIC PUMP STATION
I.E.= 1267.00 (SE)
I.E.= 1267.10 (SW)
SANITARY MANHOLE, TYPE 1
RIM = 1275.50
W/CASTING R1550
STA. 0+00, 44.8’ LT.= STA. 51+04, CL
W/CASTING R1550
TOPSOIL, SEED, FERT., AND MULCH TOPSOIL, SEED, FERT., AND MULCH
ADD FILL AS NEEDED
2% MAX
12’ MIN.
1:1 CUT SLOPE
1:1 CUT SLOPE
PARKING/TURN-A-ROUND
ABANDON PULLEY SYSTEM
MATCH TO EXISTING DRIVE
WM-1
1’
CONNECT EXISTING BUILDING LATERAL
WITH NEW 4" LATERAL TO NEW SANITARY LINE
INSTALL WATER RISER
AND 4X4 POST WITH HOSE RACK
REMOVE EXISTING METERING,
CONTROLS, AND STRUCTURE
CLEAN UP EXISTING AERATOR
AND RETURN TO OWNER
EXISTING BUILDINGS TO REMAIN
SEE SHEET E-1 FOR WORK RELATED
2" PE 90%%d BEND
PROVIDE POURED
CONCRETE BLOCKING
REMOVE EXISTING PUMPS, CONTROLS,
AND STRUCTURES
LOCATION OF BORROW PIT
PROJECT SITE
BORROW PIT SITE
FOREST ROAD 1417
CAMPGROUND
CHEQUAMEGON NATIONAL FOREST
COUNTY TRUNK M
NOTE:
DISTANCE BETWEEN PROJECT
SITE AND BORROW SITE
IS APPROXIMATELY 2.5 MILES.
REMOVE EXISTNG CHLORINE
CONTACT CHAMBER
22 LF OF 1" COPPER WATER
SERVICE WITH CURB STOP
BEAVER CREEK ROAD(FR 121)
135 LF 2" PE WATERMAIN, 6" MIN. BURY
2" X 1" PE TAP FITTING
PROVIDE CONCRETE
ANCHOR BLOCKING
8"X4" WYE CONNECTION
XXXXXXXXXXXXXXXXXXXXXXXXXXXXTSANSANEEEEEEEWWWWWWW
WM-5
WM-5
2"WS2"WS2"WSXXXXXXXX
1"WS1"WSXXXXXX
11832000
SHEET
FILE NO.
EXISTING DRIVEWAY
EXISTING BUILDINGS
TO BE
DEMOLISHED SEE NOTE 1
6’ HIGH CHAIN
LINK FENCE
PROPOSED CONTOUR GRADING
AFTER POND DEMOLITION
LOCATE SERVICE LINE FROM REMOTE BREAKER
PANELS TO NEW BUILDING SERVICE PANEL
METER MANHOLE, SEE SHEET WM-3
INSTALL 1-1/2" CONDUIT
FROM CONTROL BUILDING TO MANHOLE
PROPOSED CONTOUR GRADING
AFTER POND
DEMOLITION SEE NOTE 2
NOTE 2:
CONTRACTOR TO PROVIDE FOR
TOPSOIL, SEED, FERT., AND MULCH
PER SPECIFICATIONS ON ALL DISTRUBED
AREAS AFTER CONSTRUCTION AND
POND DEMOLITION AND GRADING
PER CONTOUR ELEVATIONS SHOWN HERE.
6 INCHES OF 34" CRUSHED AGGREGATE BASE
PROVIDE COMPACTION PER SPECIFICATIONS
12’ DRIVEWAY SECTION
I.E.= 1265.00 (TANK)
I.E. = 1269.00(END)
160 LF 3" HDPE LINE
201 L F 3
" H D
PE L
IN
E
325 LF 3" HDPE LINE
325 LF 3" HDPE LINE
SILT FENCE, INSTALL BEFORE CONSTRUCTION
APPROXIMATE IRRIGATION SPRAY COVERAGE
80’ TYPICAL SPACING
CENTER TO CENTER
NORTH IRRIGATION LINE
SOUTH IRRIGATION LINE
BASE LINE
BASE LINE
GRADE AT NORTH LINE
GRADE AT SOUTH LINE
CONNECT TO PROPOSED IRRIGATION TANK
1" VENT CAP ON THIS RISER
OPEN FOR DRAINBACK IN FALL
1" VENT CAP ON THIS RISER
OPEN FOR DRAINBACK IN FALL
I.E. 1268.00 (BEND POINT)
STA. 5+10.80 FT, RT.
IR
R
IG
A
T
IO
N P
IP
IN
G P
R O
F
IL
E
WM-2
INSTALL A 3" 45%%d BEND PE
80’ CENTER TO CENTER (TYP)
REMOVE EXISTING POST AND IRRIGATION PIPE
FILL POST HOLES WITH TOPSOIL
40’ DIAMETER SPRAY AREA
CAP END OF 3" PE HEADER PIPE
IRRIGATION RISER
SEE DETAIL ON SHEET WM-5.
IRRIGATION RISER (TYP)
SEE SHEET WM-5 FOR DETAIL
XXXXXXXXXXXXXX
E O
P S ta
.1
4+00 5+00 6+00 7+00 8+00
XX
XXXXXXXXXXXXXXXXX
WM-5
WM-5
A E
R O
B
IC
T R
E A
T M
E N
T S
Y S
T E
M
WM-4
.7
.7
.0
.0
.0
.0
.0
.0
.7
.6
.5
.4
.3
.2
.1
.1
.0
.0
.2
.4
.7
.9
.9
.8
.4
.2
.3
.5
.6
.7
.3
3+40 3+60 3+80 4+00 4+20 4+40 4+60 4+80 5+00 5+20 5+40 5+60 5+80 6+00 6+20 6+40 6+60 6+80 7+00 7+20 7+40 7+60 7+80 8+00 8+20 8+40 8+60 8+80 9+00 9+20
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
12" WATER-TIGHT
BOOT (TYP.)
6’-0" PRE-CAST
CONCRETE MANHOLE
3"
1 1/2 "1 1/2 "
A OPENING
B D
IM
/2
O V
E R
A L
L
A DIM. + 12 1/2 "
OVERALL
1/
7" 6 15/16 " 7" 6 15/16 "
30 7/8 "
14"
8"
3/
0"
IN
F
L U
E N
T F
L O
W M
E T
E R
WM-3
1272.50
STAINLESS STEEL MOUNTING
BRACKETS FOR ULTRA SONIC
LEVEL TRANSDUCER
CAST FLUME INTO MANHOLE
BASE AS REQUIRED
TRAPEZOID FLUME
TRACON OR EQUAL
8" EFFLUENT SEWER
I.E. = 1264.90
1272.50
SLOPE CONCRETE
TO MATCH FLUME
WIDTH AND ANGLE (TYP.)
8" INFLUENT
SANITARY SEWER
PROVIDE STAINLESS STEEL
MOUNTING BRACKETS FOR
ULTRA SONIC LEVEL TRANSDUCER
36" X 42" ACCESS HATCH
WITH 5/8" DIA. HOLE
2" X 2" ANGLE CLIPS
FOR KEYING TO CONCRETE
NOTES:
1) SUITABLE FOR USE IN OFF
STREET LOCATION WHERE NOT
SUBJECTED TO HIGH DENSITY
TRAFFIC.
2) PROVIDE A FULL BED OF
CLASS "A" CONCRETE UNDER
FRAME AND SUPPORT ANGLES.
S.STL. & ALUM. POSITIVE
LOCKING HOLD OPEN ARM
WITH S.STL. SPRING ASSIST
1/4" THICK DIAMOND
PATTERN ALUM. COVER PLATE
T-316 STAINLESS STEEL HINGES
WITH TAMPER PROOF FASTENERS
PRIMER REQUIRED
(COVER SHOWN IN
OPEN POSITION)
SECTION1 1/2" ALUM. COUPLING
8" INFLUENT SEWER
I.E. = 1265.00
8" EFFLUENT
SANITARY SEWER
1 - 1 1/2 " PVC ELECTRICAL CONDUITS
HATCH DOOR SIZING
A DIM B DIM LOCATION
AEROBIC PUMP TANK
IRRIGATION TANK
METER MANHOLE
WM-3
WM-3
WM-3
WM-3
1 - 1 1/2 " PVC ELECTRICAL CONDIUTS
I.E. = 1264.86I.E. = 1264.95
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
HEAD GAGE
HEAD GAGE
SCALE: 1" = 1’-0" (22x34)
SCALE: 1/2" = 1’-0" (11x17)
SCALE: 1" = 1’-0" (22x34)
SCALE: 1/2" = 1’-0" (11x17)
SCALE: 1" = 1’-0" (22x34)
SCALE: 1/2" = 1’-0" (11x17)
FLUME DETAILS
ACCESS HATCH DETAIL
FLOW METER MANHOLE PLAN
FLOW METER MANHOLE SECTION
SLAM
LOCK
LIFTING HANDLE
SCALE: 1" = 1’-0" (22x34)
SCALE: 1/2" = 1’-0" (11x17)
NOTES:
1. 3/16" MINIMAL WALL THICKNESS TO CONSIST OF ISOPHTHALIC
POLYESTER RESIN WITH 30% MINIMUM GLASS CONTENT, EXLUSIVE
OF RESIN RICH SURFACES.
2. INSIDE SURFACE SHOULD BE SMOOTH WHITE GEL COAT.
3. HEAD GAGE IS MOLDED INTO SIDE OF FLUME.
36X48 DOUBLE DOOR HATCH
USE NON-SHRINK GROUT FOR PUMP BASE
FILL RIBBED AREA AS NEEDED TO PROVIDE
FOR LEVEL PAD FOR PUMPS, FLOAT POLE, AND GUIDE RAIL.
PROVIDE WATERTIGHT SEAL AROUND ALL
PIPE PENETRATIONS THROUGH TANK WALLS
4" VENT LINE
24" DIA OPENING
WITH CONCRETE LID
WITH WARNING LABEL
DIVIDER WALL
PUMP CONTROL PANEL
WATERTIGHT STANLESS STEEL
ELECTRICAL DISCONECT/BREAKER PANEL
POWER FROM CONTROL BUILDING
1 14" PVC SCHEDULE 40
FORCEMAIN TO TREATMENT TANK
2’
SECONDARY SETTLING EQUALIZATION TANK
EFFLUENT DISCHARGE TO IRRIGATION TANK
1273.50
1273.00
1264.50
.6
20.00’
TEE BOTH PUMPS TOGETHER
1273.00
1273.50
1266.50 1266.00
1268.00
TO BLOWER POWER SUPPLY BOX
2" AIR OPENING
6" OBSERVATION OPENING
24" OPENING WITH
CONCRETE COVER
CHECK VALVE
LIFT CABLE
FLOAT RAIL SYSTEM
NEEDS TO ALLOW
ADJUSTMENT OF FLOATS
WITHOUT ENTERING TANK
TO BLOWER UNIT1 12" CONDUIT
36X48 DOUBLE DOOR
HATCH OPENING
WITH 300 PSF RATING
1257.50
BLOWER POWER BOX
1 14" CURB STOP & BOX
RISER OPERATING STEM
AND BOX
1 14" CURB STOP & BOX
TIMER FLOATS
ALARM = 1264.00
PEAK ON = 1262.25
TIMER ON = 1259.75
LWL OFF = 1259.50
AEROBIC TREATMENT TANK
1INFLUENT 8" GRAVITY
SEWER SDR 26
AEROBIC TREATMENT SYSTEM
PROVIDE OPENING IN TANK TOP FOR
MEDIA MODULE TO SET IN TANK
VERIFY TANK SIZE AND OPENING
WITH MANUFACTURE BEFORE
CONSTRUCTING TANK
SYSTEM BLOWER
WITH 2" PVC LINE
1 14" PVC DISCHARGE LINE
TO TREATMENT TANK
GUIDE RAIL
WITH QUICK DISCONNECT
1 AEROBIC TREATMENT SYSTEM SECTION
A E
R O
B
IC
T R
E A
T M
E N
T S
Y S
T E
M
WM-4
N.T.S.
WM-4
WM-4
9000 GALLON DUAL
COMPARTMENT
PRECAST TANK
EFFLUENT FILTER
BAFFLE
8" SDR 26
4" OPENING
4" CONCRETE WALL
RISER BY TANK
MANUFACTURER
1 1/4" TO 4" FERNCO COUPLING
& 4" SCH 40 PVC SUPPORT PIPE
PRECAST TANK - 2500 GALLONS
CONTRACTOR TO VERIFY SIZE AND TANK
DIMENSIONS WITH AEROBIC UNIT MANUFACTURER
AND TANK MANUFACTURER PRIOR TO DELIVERY TO SITE.
WIESER CONCRETE OR EQUAL
1266.9 +/-
6" PVC OBSERVATION OPENING W/VENTED CAP
15 LF - 4" PVC SCHEDULE 40
TO IRRIGATION PUMP TANK
AEROBIC TREATMENT
UNIT MEDIA
15 LF - 4" PVC SCHEDULE 40
TO IRRIGATION PUMP TANK
@ 4.66%
6’ - 10’
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
M
IN
GUIDE RAIL AND DISCHARGE PIPING MOUNT
SHALL BE PER PUMP MANUFACTURER
2" PVC SCHEDULE 40 PIPE
PROVIDE A CONCRETE BLOCK UNDER EACH VALVE
1266.64
1273.00
1273.50
1265.30
INLET BAFFLE
24" DIA OBSERVATION OPENING
CONCRETE COVER WITH WARNING LABEL
PROVIDE A GROUT FILLET
ALL WAY AROUND OPENING
2’
2" BALL VALVE
VALVE HANDLE EXTENSION
VALVE BOX RISER CAP
4" PVC VENT
36X48 DOUBLE DOOR HATCH
WITH LOCKING BOLT
AND LOAD RATING OF 300 PSF MIN.
2" BALL VALVE
2" BALL VALVE
2" PVC SCHEDULE 40
2" TEE
2" TEE
2" DRAINBACK LINE
2" DRAINBACK LINE
PROVIDE WATERTIGHT SEAL
AT ALL PIPE PENETRATIONS
THROUGH TANK WALLS
1265.00
2" PVC TO 3" HDPE
TRANSITION COUPLING
2" PVC TO 3" HDPE
TRANSITION COUPLING
M
IN
T
O
M
IN
T O
M A
X
EXISTING GRADE BEFORE CONSTRUCTION
SAND BACKFILLED PIPE TRENCH
IN IRRIGATION FIELD ONLY
SEE PROFILE FOR
BURY DEPTH
PROVIDE A 2" PVC TO A 3" HDPE
TRANSITION COUPLING
2" 90%%d BEND
2" 90%%d BEND
FLOAT LEVELS
HIGHWATER = 1262.22
LAG ON = 1261.22
PUMP ON = 1260.72
PUMP OFF = 1260.22
4" PVC SCHEDULE 40 IN-FLOW PIPE
2" CHECK VALVE
IR
R
IG
A
T
IO
N P
U M
P T
A N
K
WM-5
1 IRRIGATION TANK SECTION
DISTRIBUTION PIPE HEADER TO IRRIGATION RISER DETAIL
N.T.S.
N.T.S.
N.T.S.
SUBMERSIBLE PUMP
WM-5
WM-5
WM-5
WM-5
WM-5
TYPICAL POST MOUNT SERVICE PANEL
PUMP CONTROL PANEL
WATERTIGHT STAINLESS STEEL
TREATED 4X4 POST
WITH TREATED PLYWOOD
WITH A 45%%d BEVELED TOP
M
IN
M
IN
2’ X 2’ MIN. SIZE
TO WETWELL
ELECTRICAL DISCONNECT/
BREAKER PANEL POWER
FROM BUILDING
120 V CONVENIENCE OUTLET
4" VENT
TYPE NEMA 4X VENTED
FIBERGLASS ENVIROMENT
ISOLATION BOX
12" X 18" MIN.
1268.64
INSTALL 1" TAPPING SADDLE
TANK
WEISER MODEL WEHD 6000-LP
OR EQUAL
4" CONCRETE WALL
RISER BY TANK
MANUFACTURER
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
SPRAY HEAD
3/4" THREADED COUPLING
POSITION ABOVE POST
1" GALVANIZED RISER PIPE
ON END LINE RISER PROVIDE A
1" THREADED TEE COUPLING & CAP
6" FROM TOP OF POST FOR FLUSHING
1" X 10" STAINLESS STEEL STRAPS
FASTEN TO POST
WITH SCREWS
3 REQ’D PER POST
INSTALL 1" THREADED S.S. BALL VALVE
TREATED 4 X 4 POST
LENGTH AS NEEDED
SEAL TOP OF TRENCH WITH
8" OF TOPSOIL
M
IN
16’-0"
WWWW6"W
2.5 10
R E
S E
R V
O
IR
D E
M O
L
IT
IO
N
P L
A N
DM-1
5’
EXISTING 6" WATER MAIN
TO BE ABANDONED
CONTRACTOR TO CUT OFF
END AND SEAL WITH
NON-SHRINK GROUT
WWWWWWWWSSSSSS
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
EXISTING 2" FILL LINE FROM WELL
TO BE ABANDONED
CONTRACTOR TO CUT OFF END AND SEAL WITH
NON-SHRINK GROUT
EXISTING 22’ DIA.TANK
REMOVE TANK AND SLAB
FOUNDATION
SEE NOTE 1
EXISTING BUILDING
TO BE REMOVED
SEE NOTE 2
NOTE 2:
CONTRACTOR TO DEMOLISH EXISTING CONTROL BUILDING
WORK CONSISTS OF:
REMOVAL PUMPS, PIPING, AND PRESSURE TANKS
REMOVAL OF ALL ELECTRICAL PANELS, WIRING, FIXTURES AND CONDUITS.
REMOVAL OF WOOD FRAME STRUCTURE, DOORS, AND SHINGLES.
REMOVAL OF CONCRETE FLOOR SLAB WITH GRADE BEAM AROUND PERIMETER
REMOVAL OF SUBGRADE INSULATION, AND SAND BASE.
CONTRACTOR TO PROVIDE CLEAN FILL FOR VOID LEFT FROM
SLAB AND BASE MATERIAL.
TOPSOIL, SEED, FERT., AND MULCH DISTURBED AREA PER SPECIFICATIONS
NOTE 1:
CONTRACTOR TO REMOVE TANK AND FOUNDATION
DEMOLITION OF TANK CONSISTS OF :
REMOVAL OF LADDERS, PIPING, FLOATS, AND CONDUITS.
REMOVAL OF 22’ DIAMETER STEEL TOP COVER
REMOVAL OF 22’ DIAMETER STEEL TANK 16’ HIGH
REMOVAL OF CONCRETE SLAB AND FOUNDATION DOWN TO
2’ BELOW EXISTING GRADE
REMOVAL OF 3’ GRAVEL SLAB BASE MATERIAL
CONTRACTOR TO PROVIDE CLEAN FILL FOR THE VOID
LEFT FROM REMOVAL OF GRAVEL SLAB BASE
TOPSOIL, SEED, FERT., AND MULCH DISTURBED AREA PER SPECIFICATIONS
5 10 20
R E
S E
R V
O
IR
A N
D W
E L
L S
IT
E
P L
A N
W-1
1-4" PE TEE WITH CONCRETE BLOCKING
EXISTING 6" W.M.
TO BE REPLACED WITH
4" PE LINE. SEE PLAN
AND PROFILE SHEETS
FOR WATER MAIN LAYOUT
EXISTING LIGHT POLE TO BE REMOVED
REINSTALL NEXT TO NEW BUILDING
AFTER CONSTRUCTION
C A
M P G
R O
U N
D R
O A
D
RESERVOIR
OVERFLOW & DRAIN LOCATION
WELL HOUSE
INSTALL 1" COPPER WATER SERVICE
TO NEW WATER RISER WITH CURB STOP
5’ 5’
1-4" VALVE AND BOX
1-4" VALVE AND BOX
10 LF - 4" PE WATER LINE
CONNECT TO 4" D.I. STUB OUT
5’ FROM WELL BUILDING
CONTRACTOR TO VERIFY ELECTRICAL
SERVICE WITH UTILITY COMPANY
PRIOR TO DEMO OR NEW CONSTRUCTION
20 LF OF CRUSHED GRANITE WALKWAY, 4’ WIDE
SSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWEEE
EEEEEE
N O
D
A T
E R
E V
IS
IO
N B
Y
11832000
T A
Y L
O R
C O
U N
T Y
W
IS
C
O N
S
IN
C H
E Q
U A
M E
G O
N -N
IC
O
L E
T N
A T
IO
N
A L
F O
R E
IP
P
E W
A C
A M
P G
R O
U N
D W
A S
T E
W A
T E
R
SHEET
FILE NO.
RIPRAP DISCHARGE APRON
NTS
3" CLEAN BREAKER RUN STONE
NON-WOVEN TYPE R GEOTEXTILE FABRIC
SPLASH PAD FROM BUILDING
15’
PRE-CAST CONCRETE BUILDINGS
SEE WELLHOUSE BUILDING PLAN
SHEET FOR DETAILS.
FF EL = 1289.00
APPROXIMATE EDGE OF WOODED AREA
GRADE ARE TO DRAIN
INSTALL RIPRAP PER
THE RIPRAP DISCHARGE
APRON DETAIL ON THIS SHEET
INSTALL 5’ WIDE
EXISTING 2" W.M.
TO BE ABANDONED
NOTE 1: