This document is a Bid Summary (Invitation to Bid 23-0390-ITB) for Odor Management services for multiple pump stations in Florida, specifically covering preventative maintenance and repairs for odor control units. The bid was due on May 18, 2023, at 3:00 P.M. EST and includes comprehensive component lists for nine groups covering pump stations 016, 072, 0110, 196, 159, and 183. The bid encompasses detailed equipment specifications including enclosures, electrical components, fans, transformers, sensors, relays, and specialized odor control media from various manufacturers. The contract appears to be a three-year agreement with provisions for different labor rates including standard and overtime/emergency rates.
The total bid summary includes freight charges totaling $7,000 for delivery to South Cross Bayou and W. E. Dunn Water Reclamation Facilities, with a three-year lump sum total of $21,000. The bid is structured in multiple groups covering different pump stations, with each group containing specific equipment, replacement parts, and labor rates. Notably, the bid includes specialized odor control media such as Optia Premium-H carbon, potassium permanganate impregnated activated alumina, Ecosorb 606, and PERSNICKETY stage conversion and polishing media. The comprehensive bid package suggests a detailed, systematic approach to maintaining and repairing odor control units across multiple pump station locations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Section F-Bid Summary
| BID TITLE: Odor Management | Please fill in the areas higlighted in blue. |
| BID NUMBER: 23-0390-ITB | |
| Section F-Bid Summary | |
| SUBMITTAL DUE: May 18, 2023 @ 3:00 P.M. EST |
Vendor:
Group 1 - PS 016: Model Number GH4
| ITEM # | COMPONENT | PART # | DESCRIPTION | MANUFACTURER | QTY | UOM | UNIT PRICE | EXTENDED PRICE | |
| 1 | Enclosure Nema 4X SS316 30 x 20 x 10 w/Padlock Handle SST | SCE-30EL2010SS6LPPL | Enclosure Nema 4X SS316 30 x 20 x 10 w/ Padlock Handle SST | Saginaw Control & Engineering | 1 | EA | $ - 0 | $ - 0 | |
| 2 | Disconnect Sw Non-Fusible 30A 600v Nema 4X SS316 | DH361UWK316 | Disconnect Sw Non-Fusible 30A 600v Nema 4X SS316 | Cutler Hammer | 1 | EA | $ - 0 | $ - 0 | |
| 3 | Inverter Assembly DAT210, 120v | 70250-4 | Inverter Assembly DAT210, 120v | Plasma Technics Inc. | 1 | EA | $ - 0 | $ - 0 | |
| 4 | Transformer Assembly (120v) (4 Pack) | 79910-4-40 | Transformer Assembly (120v) (4 Pack) | Plasma Technics Inc. | 1 | EA | $ - 0 | $ - 0 | |
| 5 | Light Pilot 120V Green LED Complete Assembly | APW199-D-G-120 | Light Pilot Nema 4X 120V Green LED Complete Assembly | IDEC | 3 | EA | $ - 0 | $ - 0 | |
| 6 | Light Pilot 120V Amber LED Complete Assembly | APW199-D-A-120 | Light Pilot Nema 4X 120V Amber LED Complete Assembly | IDEC | 1 | EA | $ - 0 | $ - 0 | |
| 7 | Relay 120 VAC LY4 Style (Omron) 4PDT PTF Base Required | LY4-AC120 | Relay 120 VAC LY4 Style (Omron) 4PDT PTF Base Required | Omron | 1 | EA | $ - 0 | $ - 0 | |
| 8 | Base Relay (Omron LY4 Base Required) | PTF14A-E | Base Relay (Omron LY4 Base Required) | Omron | 1 | EA | $ - 0 | $ - 0 | |
| 9 | Sub Panel for 30 X 20 Enclosure | SCE-30P20 | Sub Panel for 30 X 20 Enclosure | Saginaw Control & Engineering | 1 | EA | $ - 0 | $ - 0 | |
| 10 | Door Handle SS304 Padlockable | XP11059-12 | Door Handle SS304 Padlockable | Allegis Corporation | 5 | EA | $ - 0 | $ - 0 | |
| 11 | Contactor IEC 12 amp 120v coil 3 Pole | LC1D12G7 | Contactor IEC 12 amp 120v coil 3 Pole | Schneider Electric | 1 | EA | $ - 0 | $ - 0 | |
| 12 | Head Assy Ozone Generating 6-Plate New Generation (2015) | 002710-NG | Head Assy Ozone Generating 6-Plate New Generation (2015) | EngA | 4 | EA | $ - 0 | $ - 0 | |
| 13 | Plate Ceramic Ozone 5.00 x 7.00 x 0.047 Coortek | ADS96R | Plate Ceramic Ozone 5.00 x 7.00 x 0.047 Coortek | Coorstek | 48 | EA | $ - 0 | $ - 0 | |
| 14 | Switch Nema 12 3 Position 2NO | ASW320 | Switch Nema 4X 3-Position 2NO | IDEC | 1 | EA | $ - 0 | $ - 0 | |
| 15 | Relay 120 VAC DPDT LY2 STYLE | ||||||||
| (OMRON) PTF Base Required | LY2-AC120 | Relay 120 VAC DPDT LY2 STYLE | |||||||
| (OMRON) PTF Base Required | Omron | 7 | EA | $ - 0 | $ - 0 | ||||
| 16 | Base 8 Pin (51X120 8 PIN BASE) Omron | PTF08A-E | Base 8 Pin (51X120 8 PIN BASE) Omron | Omron | 7 | EA | $ - 0 | $ - 0 | |
| 17 | Sensor Magentic Reed(Door) Cherry#MP201901 | CH407-ND | Sensor Magnetic Reed(Door) Cherry#MP201901 | Digi-Key Corp | 3 | EA | $ - 0 | $ - 0 | |
| 18 | Sensor Proximity (Door Magnet Reed Switch) AS201901 | CH413-ND | Sensor Proximity (Door Magnet Reed Switch) AS201901 | Digi-Key Corp | 3 | EA | $ - 0 | $ - 0 | |
| 19 | Pressure Switch Low Differential 0.15 - 0.55 | 1910--0 | Pressure Switch Low Differential 0.15 - 0.55 | Dwyer Instruments Inc. | 2 | EA | $ - 0 | $ - 0 | |
| 20 | Pipe adaptor Nylon 1/4 Tube ID x 1/4 NPT | ||||||||
| Male PKG/10 | 5372K112 | Pipe Adaptor Nylon 1/4 Tube ID x 1/4 NPT Male PKG/10 | Mcmaster-Carr Supply Co | 3 | EA | $ - 0 | $ - 0 | ||
| 21 | Pipe Adaptor Nylon 1/4 Tube ID x 1/4 NPT Female PKG/10 | 5372K212 | Pipe Adaptor Nylon 1/4 Tube ID x 1/4 NPT Female PKG/10 | Mcmaster-Carr Supply Co | 3 | EA | $ - 0 | $ - 0 | |
| 22 | Time Delay Relay (Delay on Make) 0-1000 Sec 19-288V | 438UX | Time Delay Relay (Delay on Make) 0-1000 Sec 19-288V | Artisan Controls Corp | 1 | EA | $ - 0 | $ - 0 | |
| 23 | Hour Meter 120V T51E2 ENM | 207-0008 | Hour Meter 120V T51E2 ENM | ENM | 1 | EA | $ - 0 | $ - 0 | |
| 24 | Cam Roller Single Point Stainless | 8-325-268 | Cam Roller Single Point Stainless | Allegis Corporation | 5 | EA | $ - 0 | $ - 0 | |
| 25 | Pipe Adaptor Nylon 1/4 Tube ID x 1/8 NPT Male | 5372K111 | Pipe Adaptor Nylon 1/4 Tube ID x 1/8 NPT Male | Mcmaster-Carr Supply Co | 3 | EA | $ - 0 | $ - 0 | |
| 26 | Hose Tygon Ozone & UV Resistant F-4040-A 1/4 ID | 5552K25 | Hose Tygon Ozone & UV Resistant F-4040-A 1/4 ID | Mcmaster-Carr Supply Co | 10 | EA | $ - 0 | $ - 0 | |
| Group 1 Subtotal: | $ - 0 |
Group 2 - PS 016: Model Number LM3/O
| ITEM # | COMPONENT | PART # | DESCRIPTION | MANUFACTURER | QTY | UOM | UNIT PRICE | EXTENDED PRICE |
| 27 | Enclosure Nema 4X SS316 36 x 24 x 10 Panel w/Padlock Han SST | SCE-36EL2410SS6LPPL | Enclosure Nema 4X SS316 36 x 24 x 10 Panel w/Padlock Han SST | Saginaw Control & Engineering | 1 | EA | $ - 0 | $ - 0 |
| 28 | Exhaust air Fan | 165-BC-SISW ARR 3 CL II | Centrifugal Fan BC 165 SISW CL II Arr3 | TwinCity | 1 | EA | $ - 0 | $ - 0 |
| 29 | Exhaust air Fan Drive (1 - B-6.2) | 1B62 | Sheave 6.55 OD A/B Combination 1 Groove | Baldor | 1 | EA | $ - 0 | $ - 0 |
| 30 | Exhaust air Motor Drive ((B) 1 - B-9.4) | 1B94 | Sheave 9.75 OD A/B Combination 1 Groove | Baldor | 1 | EA | $ - 0 | $ - 0 |
| 31 | Supply Fan Motor - Super 'E' TEFC (1750) 7 1/2 HP 460/3/60 | EM3710T | Motor 7.5 HP 3Ph 1800 230/460V Super-E TEFC (FLA 18.8/9.4) | Baldor | 1 | EA | $ - 0 | $ - 0 |
| 32 | Disconnect Sw Non-Fusible 30A 600v Nema 4X SS316 | DH361UWK316 | DisCOMect Sw Non-Fusible 30A 600v Nema 4X SS316 | Cutler Hammer | 1 | EA | $ - 0 | $ - 0 |
| 33 | VFD VT 460V 7.5 HP 11A Yaskawa NEMA 4X Normal Duty | CIMR-VU4A0011GAA | VFD VT 460V 7.5 HP 14A Yaskawa NEMA 4X Normal Duty | Yaskawa Electric America, Inc. | 1 | EA | $ - 0 | $ - 0 |
| 34 | Panel Cooling System, NEMA 3R/4X, SS316, 2000BTUH, A/C w/Heat | IQ2000VXS | Panel Cooling System, NEMA 3R/4X, SS316, 2000BTUH, A/C w/Heat | Ice Qube, Inc. | 1 | EA | $ - 0 | $ - 0 |
| 35 | Transformer 3000 VA 480/120 | ENGA3000-36 | Transformer 3000 VA 480/120 | EngA | 1 | EA | $ - 0 | $ - 0 |
| 36 | Sub Panel for 36 X 24 Enclosure | SCE-36P24 | Sub Panel for 36 X 24 Enclosure | Saginaw Control & Engineering | 1 | EA | $ - 0 | $ - 0 |
| 37 | Light Pilot 24V Green LED Complete Assembly | APW199-D-G-24 | Light Pilot Nema 4X 24V Green LED Complete Assembly | IDEC | 1 | EA | $ - 0 | $ - 0 |
| 38 | Light Pilot 24V Amber LED Complete Assembly | APW199-D-A-24 | Light Pilot Nema 4X 24V Amber LED Complete Assembly | IDEC | 1 | EA | $ - 0 | $ - 0 |
| 39 | Signal Splitter (1) 0-10VDC / 4-20mA Input = (2) 4-20mA Out | ARM2 | Signal Splitter (1) 0-10VDC / 4-20mA Input= (2) 4-20mA Out | Automation Components Inc. | 2 | EA | $ - 0 | $ - 0 |
| 40 | CAREL Program (CRD Small) | CAREL PROGRAM-CR D-SMALL | CAREL PROGRAM-CRD-SMALL | Carel | 1 | EA | $ - 0 | $ - 0 |
| 41 | Transmitter Gas F12 Toxic w/ Heated Sensor (F12iS-1-3-1-1) | 00-1724 | Transmitter Gas F12 Toxic w/ Heated Sensor (F12iS-1-3-1-1) | Analytical Technology, Inc. | 3 | EA | $ - 0 | $ - 0 |
| 42 | Sensor Cap & Flowcell Assembly F2 | 03-0118 | Sensor Cap & Flowcell Assembly F12 | Analytical Technology, Inc. | 3 | EA | $ - 0 | $ - 0 |
| 43 | Sensor Hydrogen Sulfide 0-10ppm H10-24 H2S | 00-1020 | Sensor Hydrogen Sulfide 0-10ppm H10-24 H2S | Analytical Technology, Inc. | 2 | EA | $ - 0 | $ - 0 |
| 44 | Ozone (03) Sensor0-1/5ppm | 00-1008 | Ozone (03) Sensor 0-1/5ppm | Analytical Technology, Inc. | 1 | EA | $ - 0 | $ - 0 |
| 45 | Relay Staging Module c/w 0-10vdc Input | RIBMN24Q4C-PX | Relay Staging Module c/w 0-10vdc Input | Kele | 2 | EA | $ - 0 | $ - 0 |
| 46 | Relay 24 VAC LY3 Style (Omron) 3PDT PTF Base Required | LY3-AC24 | Relay 24 VAC LYJ Style (Omron) 3PDT PTF Base Required | Omron | 1 | EA | $ - 0 | $ - 0 |
| 47 | Base Relay (Omron LY3 Base Required) | PTF11A | Base Relay (Omron LY3 Base Required) | Omron | 1 | EA | $ - 0 | $ - 0 |
| 48 | Door Handle SS304 Padlockable | XP11059-12 | Door Handle SS304 Padlockable | Allegis Corporation | 4 | EA | $ - 0 | $ - 0 |
| 49 | EngA Standard Pleated with MERV 13 rating | 141-604-319 | Filter 4D x 24H x 12W Merv 13 | AAF | 4 | EA | $ - 0 | $ - 0 |
| 50 | Supply Fan Motor Cootactor LC1D12B7[24V] | LC1D12B7 | Contactor IEC 12 amp 24v coil 3 Pole | Schneider Electric | 1 | EA | $ - 0 | $ - 0 |
| 51 | Reactor Line 7.5 hp 460v 3%-Z | KDRA4L | Reactor Line 7.5 hp 460v 3%-Z | Schneider Electric | 2 | EA | $ - 0 | $ - 0 |
| 52 | Control Relay (24v) | R8222D1006/B | Relay 24 V 12 AMP DPDT | Honeywell | 8 | EA | $ - 0 | $ - 0 |
| 53 | Switch Nema 12 3 Position 2NO | ASW320 | Switch Nema 4X 3-Position 2NO | IDEC | 1 | EA | $ - 0 | $ - 0 |
| 54 | Time Delay Relay (Delay on Make) 0-1000 Sec 19-288V | 438UX | Time Delay Relay (Delay on Make) 0-1000 Sec 19-288V | Artisan Controls Corp | 1 | EA | $ - 0 | $ - 0 |
| 55 | Transformer 20 VA 24/24v Class 2 Isolating | 2024MWSH | Transformer 20 VA 24/24v Class 2 Isolating | Intec Wilson Mohr Inc. | 1 | EA | $ - 0 | $ - 0 |
| 56 | Transducer Low Pressure 0-6", 0-10", 0-12" WC | LP3A02 | Transducer Low Pressure 0-6", 0-10", 0-12" WC | Greystone Energy Systems Inc | 1 | EA | $ - 0 | $ - 0 |
| 57 | CAREL Program (CRD Small) | P+500BAA00ES0 | Controller PCO5+ Small FB/BMS NO OPTO, USB, Built-In PGD1 | Carel | 1 | EA | $ - 0 | $ - 0 |
| 58 | CAREL Program (CRD Small) | P+50CON0S0 | Connector Kit for PCO5+ Small | Carel | 1 | EA | $ - 0 | $ - 0 |
| 59 | Relay 24 VDC DPDT 10A 8-PIN LY2 STYLE LY2-DC24 | Z789-ND | Relay 24 VDC DPDT 10A 8-PIN LY2 STYLE LY2-DC24 | Omron | 2 | EA | $ - 0 | $ - 0 |
| 60 | Base 8 Pin (51X120 8 PIN BASE) Omron | PTF08A-E | Base 8 Pin (51X120 8 PIN BASE) Omron | Omron | 2 | EA | $ - 0 | $ - 0 |
| 61 | Standard XFMR | ENGAIR75-20 | Transformer75 VA 120/24 1 Ph Open (EXS114502) | EngA | 1 | EA | $ - 0 | $ - 0 |
| 62 | Standard XFMR | ENGA150-35 | Transformer 150 VA 480/24 | EngA | 1 | EA | $ - 0 | $ - 0 |
| 63 | Standard XFMR | ENGA1000-36 | Transformer 1000 VA 480/120 | EngA | 1 | EA | $ - 0 | $ - 0 |
| 64 | Cam Roller Single Point Stainless | 8-325-268 | Cam Roller Single Point Stainless | Allegis Corporation | 4 | EA | $ - 0 | $ - 0 |
| 65 | Exhaust air Fan Bushing (1 - B-SDS-1 3/16) | SDSX1-3/16 | Bushing Drive (SDSXl-3/16) | Baldor | 1 | EA | $ - 0 | $ - 0 |
| 66 | Exhaust air Motor Bushing ((B) 1 - B-SDS-1 3/8) | SDSX1-3/8 | Bushing Drive (SDSX1-3/8) | Baldor | 1 | EA | $ - 0 | $ - 0 |
| Group 2 Subtotal: | $ - 0 |
Group 3 - PS 016: Optia Adsorptive Media (OEM)
| ITEM # | COMPONENT | DESCRIPTION | MANUFACTURER | QTY | UOM | UNIT PRICE | EXTENDED PRICE | ||
| 67 | Optia Premium-H | Wood Based Pelletized Carbon | Optia | 2 | EA | $ - 0 | $ - 0 | ||
| 68 | Optia 8D | Potassium permanganate impregnated activated alumina | Optia | 2 | EA | $ - 0 | $ - 0 | ||
| 69 | Optia | Granular activated carbon (coconut shell) | Optia | 2 | EA | $ - 0 | $ - 0 | ||
| 70 | Optia | Pulling carbon samples from the top and bottom of the carbon vessel to determine the life of the | |||||||
| media | Optia | 4 | EA | $ - 0 | $ - 0 | ||||
| 71 | Labor and Equipment | Offloading of new adsorptive media, removal and disposal of old adsorptive media, installation of new media retention screens, installation of new adsorptive media | 15 | Hour(s) | $ - 0 | $ - 0 | |||
| Group 3 Subtotal: | $ - 0 |
Group 4 - PS 016: Labor Rates
| ITEM # | DESCRIPTION | QTY | UOM | UNIT PRICE | EXTENDED PRICE | |
| 72 | Pump Station 016: Hourly Labor Rate (Mon thru Fri 8:00 A.M. to 5:00 P.M.) | 65 | Hour(s) | $ - 0 | $ - 0 | |
| 73 | Pump Station 016: Overtime/Emergency Labor Rate (Before 8:00 A.M. or after 5:00 P.M. and Weekends & Holidays) | 15 | Hour(s) | $ - 0 | $ - 0 | |
| Group 4 Subtotal: | $ - 0 |
Subtotal for Pump Station 016: $ - 0
Group 5 - PS 072: Model Number LM1/O/MV/GH1
| ITEM # | COMPONENT | PART # | DESCRIPTION | MANUFACTURER | QTY | UOM | UNIT PRICE | EXTENDED PRICE | |
| 74 | Disconnect Sw Non-Fusible 60A | H322DS | NEMA 4X 316SS Disconnect Sw Non-Fusible 60A | Siemens | 1 | EA | $ - 0 | $ - 0 | |
| 75 | Transformer Assembly (120v) (1 Pack) | 50135 | Transformer Assembly (120v) (1 Pack) | Plasma Technics Inc. | 1 | EA | $ - 0 | $ - 0 | |
| 76 | Inverter Assembly DA T2 10, 120v | 70250-4 | Inverter Assembly DA T2 10, 120v | Plasma Technics Inc. | 1 | EA | $ - 0 | $ - 0 | |
| 77 | Head Assy Ozone Generating | 002710-NG | Head Assy Ozone Gen 6 Plate new Generation 2015 | EngA | 1 | EA | $ - 0 | $ - 0 | |
| 78 | Plate Ceramic Ozone 5.00 x 7.00 x 0.047 | ADS96R | Plate Ceramic Ozone 5.00 x 7.00 x 0.047 | Coorstek | 6 | EA | $ - 0 | $ - 0 | |
| 79 | Contactor IEC 12 amp 120v coil 3 Pole | LCJDl2G7 | Contactor IEC 12 amp 120v coil 3 Pole | Schneider Electric | 1 | EA | $ - 0 | $ - 0 | |
| 80 | Relay 120 VAC LY4 Style (Omron) 4PDT | LY4-AC120 | Relay 120 VAC LY4 Style 4PDT (Base required) | Omron | 1 | EA | $ - 0 | $ - 0 | |
| 81 | Base Relay | PTF14A-E | PTF Base for LY4 Relay | Omron | 1 | EA | $ - 0 | $ - 0 | |
| 82 | Relay 120 VAC DPDT LY2 STYLE | LY2-AC120 | Relay 120 VAC DPDT L Y2 STYLE (PTF Base Required) | Omron | 8 | EA | $ - 0 | $ - 0 | |
| 83 | Base 8 Pin (51Xl20 8 PIN BASE) | PTFO8A-E | Base 8 Pin (51X120 8 PIN BASE) | Omron | 8 | EA | $ - 0 | $ - 0 | |
| 84 | Switch Nema 12 3 Position 2NO | ASW320 | Switch Nema 12 3 Position 2NO | IDEC | 1 | EA | $ - 0 | $ - 0 | |
| 85 | Sensor Magnetic Reed (door) | CH407-ND | Sensor Magentic Reed(Door) Cherry#MP201901 | Digi-Key Corp. | 3 | EA | $ - 0 | $ - 0 | |
| 86 | Sensor Proximity Switch (door) | CH413-ND | Sensor Proximity (Door Magnet Reed ) AS201901 | Digi-Key Corp. | 3 | EA | $ - 0 | $ - 0 | |
| 87 | Pressure Switch Low Differential 0.15-0.55 | 1910-0 | Pressure Switch Low Differential 0.15-0.55 | Dwyer Instruments Inc. | 2 | EA | $ - 0 | $ - 0 | |
| 88 | Time Delay Relay | 438UX | Time Delay Relay (make delay 0-1000 Sec )19-288V | Artisan Controls Corp | 1 | EA | $ - 0 | $ - 0 | |
| 89 | Hour Meter 120V T51E2 ENM | 207-0008 | Hour Meter 120V T51E2 ENM | ENM | 1 | EA | $ - 0 | $ - 0 | |
| 90 | Exhaust air Fan | 805F JRW CL SD | Exhaust air Fan | Twin City | 1 | EA | $ - 0 | $ - 0 | |
| 91 | Exhaust Fan Motor | D48520915 | 1/2 HP TEFC 230V/3PH/60HZ. | Baldor | 1 | EA | $ - 0 | $ - 0 | |
| 92 | VFD | KBVF23D | VFD | KV Elect | 1 | EA | $ - 0 | $ - 0 | |
| 93 | EngA Standard Pleated with MERV 13 | 16 x 20 x 4 | 4" 16 x 20 MERV 13 Rated Filter | AAF | 1 | EA | $ - 0 | $ - 0 | |
| 94 | Signal Splitter | ARM2 | {I) 0-10VDC /4-20mA Input = (2) 4-20mA Out | Automation Components Inc. | 2 | EA | $ - 0 | $ - 0 | |
| 95 | CAREL Program (CRD Small) | CRD-SMALL | CAREL Program (CRD Small) | Carel | 1 | EA | $ - 0 | $ - 0 | |
| 96 | Transmitter Toxic Gas F12 | 00-1724 | Toxic Gas Transmitter w/ Heated Sensor | ||||||
| (F12iS-1-3-1-1) | Analytical Technology, Inc. | 3 | EA | $ - 0 | $ - 0 | ||||
| 97 | Sensor Cap & Flowcell Assembly F 12 | 03-0118 | Sensor Cap & Flowcell Assembly F 12 | Analytical Technology, Inc. | 3 | EA | $ - 0 | $ - 0 | |
| 98 | Sensor Hydrogen Sulfide | 00-1020 | Hydrogen Sulfide Sensor 0-10ppm H10-24 H2S | Analytical Technology, Inc. | 2 | EA | $ - 0 | $ - 0 | |
| 99 | Ozone Sensor | 00-1008 | Ozone (03) Sensor 0-1/5ppm | Analytical Technology, Inc. | 1 | EA | $ - 0 | $ - 0 | |
| Group 5 Subtotal: | $ - 0 |
Group 6 - PS 072: Labor Rates
| ITEM # | DESCRIPTION | QTY | UOM | UNIT PRICE | EXTENDED PRICE | |
| 100 | Pump Station 072: Hourly Labor Rate (Mon thru Fri 8:00 A.M. to 5:00 P.M.) | 65 | Hour(s) | $ - 0 | $ - 0 | |
| 101 | Pump Station 072: Overtime/Emergency Labor Rate (Before 8:00 A.M. or after 5:00 P.M. and Weekends & Holidays) | 15 | Hour(s) | $ - 0 | $ - 0 | |
| Group 6 Subtotal: | $ - 0 |
Subtotal for Pump Station 072: $ - 0
Group 7 - PS 0110 and 196: A1130BA01
| ITEM # | DESCRIPTION | PART # | QTY | UOM | UNIT PRICE | EXTENDED PRICE |
| 102 | PS 0110 and 196: Ecosorb 606 - First Year Costs | 606-55GAL | 2 | EA | $ - 0 | $ - 0 |
| 103 | PS 0110 and 196: Ecosorb 606 - Second Year Costs | 606-55GAL | 2 | EA | $ - 0 | $ - 0 |
| 104 | PS 0110 and 196: Ecosorb 606 - Third Year Costs | 606-55GAL | 2 | EA | $ - 0 | $ - 0 |
| Group 7 Subtotal: | $ - 0 |
Subtotal for Pump Stations 110 and 196: $ - 0
Group 8 - PS 159 and 183
| ITEM # | DESCRIPTION | QTY | UOM | UNIT PRICE | EXTENDED PRICE | |
| 105 | PS 159 and 183: PERSNICKETY® Stage 1 H2S CONVERTING MEDIA | 1 | EA | $ - 0 | $ - 0 | |
| 106 | PS 159 and 183: PERSNICKETY® Stage 2 POLISHING MEDIA | 1 | EA | $ - 0 | $ - 0 | |
| Group 8 Subtotal: | $ - 0 |
Group 9 - PS 159 and 183: Labor Rates
| ITEM # | DESCRIPTION | QTY | UOM | UNIT PRICE | EXTENDED PRICE | |
| 107 | PS 159 and 183: Hourly Labor Rate (Mon thru Fri 8:00 A.M. to 5:00 P.M.) | 65 | Hour(s) | $ - 0 | $ - 0 | |
| 108 | PS 159 and 183: Overtime/Emergency Labor Rate (Before 8:00 A.M. or after 5:00 P.M. and Weekends & Holidays) | 15 | Hour(s) | $ - 0 | $ - 0 | |
| Group 9 Subtotal: | $ - 0 |
Subtotal for Pump Stations 159 and 183: $ - 0
Group 10 - Shipping
| ITEM # | DESCRIPTION | EXTENDED PRICE | |
| 109 | Freight Charges - South Cross Bayou Water Reclamation Facility | $ 5,000.00 | |
| 110 | Freight Charges - W. E. Dunn Water Reclamation Facility | $ 2,000.00 | |
| Group 10 Subtotal: | $ 7,000.00 |
| BID SUMMARY TABLE | |
| Pump Station 016 Total | $ - 0 |
| Pump Station 072 Total | $ - 0 |
| Pump Stations 110 and 196 Total | $ - 0 |
| Pump Stations 159 and 183 Total | $ - 0 |
| Shipping Total | $ 7,000.00 |
| 3-YEAR LUMP SUM TOTAL | $ 21,000.00 |
Vendor Notes image1.jpeg