ADDENDUM 6 Docs.pdf
PDF 5 MB Posted
- Attached to
- 4750 NMDA New Building
- Solicitation number
- 2025-ITB-646
- Issued by
- New Mexico
About this file
The provided documents are design and specification files for the New Mexico Department of Agriculture (NMDA) Office Building project located at 967 Agriculture Way in Las Cruces, New Mexico. The project involves a comprehensive architectural and engineering design for a new office facility, with detailed plans covering multiple aspects including floor plans, interior elevations, finishes, mechanical systems, food service equipment, electrical rough-ins, and specialized areas like a demonstration kitchen and servery. The design documents are dated October 9, 2024, with recent addenda issued on November 22, 2024, and December 5, 2024, and are prepared by Dekker Perich Sabatini Architecture.
The design specifications cover extensive details including fluid-applied flooring systems, metal wall panels, interior finishes, and equipment specifications. The project includes specialized areas such as a test kitchen, open office spaces, conference rooms, administrative offices, and support spaces. Specific material selections are detailed, including wall tiles from manufacturers like Daltile and Fireclay Tile, resilient flooring, acoustical ceilings, and custom display cases. The design emphasizes thermal performance, weather barriers, and integration of mechanical and electrical systems, with particular attention to food service and kitchen equipment requirements. The project appears to be a modern, functionally designed office building with high-quality finishes and specialized work areas for the New Mexico Department of Agriculture.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Wage Rates.pdf | ||
| BID Form rev 2.1.2024.pdf | ||
| Subcontractor Listing.pdf | ||
| ADDENDUM 3.pdf | ||
| Addendum 7.js | JS file | |
| CIVIL CALCULATIONS.pdf | ||
| Specifications and Drawings.js | JS file | |
| ADDENDUM 8.pdf | ||
| ADDENDUM 5.pdf | ||
| Addendum 1 Site Visit.pdf | ||
| NMSU Construction TC 3-19-24 UGC -- Clean Copy.pdf | ||
| Addendum 4.pdf | ||
| ADDENDUM 2.pdf | ||
| ADDENDUM 6.pdf | ||
| 1267644-event.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
03 3511 CONCRETE FINISHES (C-X)
C-1 MFG LATICRETE
PRODUCT L&M SEAL HARD
COLOR CLEAR
NOTES CONCRETE FLOOR SEALER
C-2 MFG UNITED STATIC CONTROL PRODUCTS
PRODUCT ELECTRASEAL
COLOR ANTI STATIC CONCRETE SEALER
NOTES CONCRETE FLOOR SEALER
06 4100 UPHOLSTERY FABRIC (F-X)
F-1 MFG ARCHITEX
STYLE PENDLESOME
COLOR PLAINS
SIZE 55" WIDTH
NOTES BANQUETTE BACK FABRIC
F-2 MFG STINSON
STYLE MODENA 2.0
COLOR MOD 262 CAFFE
SIZE 54" WIDTH
NOTES BANQUETTE SEAT FABRIC
06 4100 PLASTIC LAMINATE (PL-X)
PL-1 MFG WILSONART
COLOR NEOWALNUT
FINISH MATTE
EDGE BAND TO MATCH
NOTES BREAKROOM
PL-2 MFG WILSONART
COLOR FAWN WALNUT CROSSGRAIN
FINISH MATTE
EDGE BAND TO MATCH
NOTES OFFICE
PL-3 MFG WILSONART
STYLE TRACELESS
COLOR IVORY VELVET ELM
FINISH ULTRA MATTE
EDGE BAND TO MATCH
NOTES TEST KITCHEN
PL-4 MFG CHEMETAL
STYLE 600 SERIES
COLOR WEATHERED ALUMINUM
SIZE LAMINATE BACKER .055" THICK
NOTES RECEPTION DESK
PL-5 MFG FORMICA
COLOR STONE GRAFIX 503-58
FINISH MATTE
NOTES OFFICE
06 8316 FIBERGLASS REINFORCED PLASTIC PANELS (FRP-X)
FRP-1 MFG CRANE
PRODUCT KEMLITE GLASBOARD
FINISH PEBBLED EMBOSSED
SIZE 48" H
COLOR WHITE 85
NOTES JANITORS CLOSET
09 3000 TILE (T-X)
T-1 MFG DALTILE
STYLE STARE KINTSUGI
COLOR METAL GROOVE IVORY 281D
FINISH MATTE
SIZE 48" X 110"
GROUT CBP #545 BLEACHED WOOD
INSTALL HORIZONTAL STACK
NOTES LARGE FORMAT WALL TILE
T-2 MFG ATLAS CONCORD
STYLE COVE TERRA
COLOR ASH
FINISH STANDARD
SIZE 24" X 48"
GROUT CBP #183 CHATEAU
INSTALL STRAIGHT STACK
NOTES FLOOR TILE
T-3 MFG FIRECLAY TILE
STYLE THIN BRICK
COLOR ALLEGHENY V4
FINISH SATIN
SIZE 2.5" X 8"
GROUT CBP #183 CHATEAU
INSTALL HORIZONTAL STACK
NOTES ACCENT WALL TILE
T-5 MFG CONCEPT SURFACES
STYLE DIVINE
COLOR COPPER CHEVRON
FINISH MATTE
SIZE 13" X 36"
GROUT CBP #95 SABLE BROWN
INSTALL HORIZONTAL STACK,
FULL HEIGHT FROM FLOOR
TO CEILING
NOTES ACCENT WALL TILE
T-6 MFG CONCEPT SURFACES
STYLE PUEBLO
COLOR AVORIO
FINISH MATTE
SIZE 24" X 48"
GROUT CBP #172 URBAN PUTTY
INSTALL HORIZONTAL STACKED
NOTES WALL TILE
T-7 MFG CONCEPT SURFACES
STYLE PUEBLO
COLOR AVORIO
FINISH ANTI-SLIP
SIZE 24" X 48"
GROUT CBP #172 URBAN PUTTY
INSTALL HORIZONTAL STACKED
NOTES FLOOR TILE
T-8 MFG CREATIVE MATERIAL CORP.
STYLE EMBRACE
COLOR TERACOTTA
FINISH MATTE
SIZE 24" X 24"
GROUT CBP #386 OYSTER GRAY
INSTALL HORIZONTAL STACK
NOTES WALL & FLOOR TILE
T-9 MFG CREATIVE MATERIAL CORP.
STYLE EMBRACE
COLOR BLUE
FINISH MATTE
SIZE 24" X 24"
GROUT CBP #386 OYSTER GRAY
INSTALL HORIZONTAL STACK
NOTES FLOOR TILE
T-10 MFG CREATIVE MATERIAL CORP.
STYLE IVORY
COLOR GREIGE
FINISH MATTE
SIZE 24" X 24"
GROUT CBP #386 OYSTER GRAY
INSTALL HORIZONTAL STACK
NOTES FLOOR TILE
T-11 MFG ARIZONA TILE
STYLE CASTLE BRICK
COLOR WHITE
FINISH MATTE
SIZE 2 12" X 10"
GROUT #541 WALNUT
NOTES TEST KITCHEN
09 3000 TILE ACCESSORIES (TA-X)
TA-1 MFG ATLAS CONCORD
STYLE COVE TERRA
COLOR ASH
SIZE 6" X 12"
INSTALL T-2 WALL BASE
09 5100 ACOUSTICAL CEILINGS (ACT-X)
AC-1 MFG ARMSTRONG
STYLE CALLA ULTIMA
SIZE 24" X 24"X 1"
NRC/CAC 0.70/40
GRID 9/16" SQUARE TEGULAR LAY-IN
NOTES GENERAL CEILINGS
AC-2 MFG ARMSTRONG
STYLE KITCHEN ZONE VINYL
SIZE 24" X 24"X 1"
NRC/CAC 0.85/35
GRID 15/16" SQUARE LAY-IN
NOTES KITCHEN & LAB
09 6500 RESILIENT BASE (RA-X)
RA-1 MFG JOHNSONITE
STYLE 4" TRADITIONAL VINYL BASE
COLOR 31 ZEPHYR CB
NOTES GENERAL WALL BASE
RA-2 MFG JOHNSONITE
STYLE 4" TRADITIONAL VINYL BASE
COLOR 76 CINNAMON
NOTES AT DISPLAY CASE
09 6500 RESILIENT FLOORING (RF-X)
RF-1 MFG SHAW CONTRACT
STYLE INLET
COLOR SPINDLE 26140
SIZE 9" X 48"
WEAR 20 MIL
INSTALL 1/3 STAGGER UNIT FLOORING
NOTES
09 6700 FLUID APPLIED FLOORING (FF-X)
FF-1 MFG TERROXY RESINOUS FLOORING
STYLE URETHANE CONCRETE SLURRY
COLOR MEDIUM BLUE
INSTALL INTEGRAL COVE BASE
NOTES KITCHEN
FF-2 MFG TERROXY RESINOUS FLOORING
STYLE INDUSTRIAL THIN SET
COLOR MEDIUM GRAY 2.0
INSTALL INTEGRAL COVE BASE
NOTES LAB
09 6813 TILE CARPETING (TCP-X)
TCP-1 MFG INTERFACE
STYLE TCP-3 - TCP-8
COLLECTION WOVEN GRADIENCE
COLOR TCP-3 - TCP-8
SIZE 20" X 20"
INSTALL SEE AF102A & AF102B FOR LAYOUT
TCP-2 MFG PATCRAFT
STYLE 10316
COLLECTION PASEO
COLOR GARNET 00875
SIZE 24" X 24"
INSTALL STACK
NOTES WALK-OFF CARPET
TCP-3 MFG INTERFACE
STYLE WG100
COLLECTION WOVEN GRADIENCE
COLOR 108049 GRIEGE
SIZE 20" X 20"
INSTALL SEE AF102A & AF102B FOR LAYOUT
TCP-4 MFG INTERFACE
STYLE WG100
COLLECTION WOVEN GRADIENCE
COLOR 108050 VOLCANIC
SIZE 20" X 20"
INSTALL SEE AF102A & AF102B FOR LAYOUT
TCP-5 MFG INTERFACE
STYLE WG200
COLLECTION WOVEN GRADIENCE
COLOR 107668 GREIGE/CARIBBEAN
SIZE 20" X 20"
INSTALL SEE AF102A & AF102B FOR LAYOUT
TCP-6 MFG INTERFACE
STYLE WG100
COLLECTION WOVEN GRADIENCE
COLOR 108059 CARIBBEAN
SIZE 20" X 20"
INSTALL SEE AF102A & AF102B FOR LAYOUT
NOTES
TCP-7 MFG INTERFACE
STYLE WG200
COLLECTION WOVEN GRADIENCE
COLOR 108059 GREIGE/CLAY
SIZE 20" X 20"
INSTALL SEE AF102A & AF102B FOR LAYOUT
TCP-8 MFG INTERFACE
STYLE WG100 CLAY
COLLECTION WOVEN GRADIENCE
COLOR 107667 GREIGE/CLAY
SIZE 20" X 20"
INSTALL SEE AF102A & AF102B FOR LAYOUT
09 8430 SOUND ABSORBING UNITS (SA-X)
SA-1 MFG ARKTURA
COLLECTION SOUND BAR
COLOR OAK
SIZE 3"W X 10"H X LENGTH VARIES
INSTALL SEE REFLECTED CEILING PLAN
NOTES LOBBY CEILING FEATURE
SA-2 MFG FRASCH
COLLECTION BLADE BAFL
COLOR TO BE SELECTED FROM MANUFACTURERS
FULL RANGE
SIZE 2.75"W X 12"H - LENGTHS VARY
INSTALL SEE REFLECTED CEILING PLAN
NOTES OPEN OFFICES
SA-3 MFG FRASCH
COLLECTION BRIK FLOW 4X8
STYLE TO BE SELECTED FROM MANUFACTURERS
FULL RANGE
COLOR IVORY
SIZE 48" X 96"
INSTALL FURRING STRIPS PER MANUFACTURERS
INSTRUCTIONS
NOTES TACKABLE SURFACE
09 7200 WALL COVERINGS (WC-X)
WC-1 MFG SPOONFLOWER
COLLECTION TYPE II
PATTERN JUST CATTLE #11578947
COLOR NATURAL LIGHT
SIZE 2' WIDTH 27 FT. ROLL LENGTH
MATCH STRAIGHT MATCH, NON REVERSE HANG
09 9123 PAINTING (P-X)
P-1 MFG SHERWIN WILLIAMS
COLOR SW 7010 WHITE DUCK
NOTES GENERAL WALL & CEILING
P-2 MFG SHERWIN WILLIAMS
COLOR SW 6072VERSATILE GRAY
NOTES ACCENT,
HALLOW METAL DOORS AND
FRAMES
P-3 MFG SHERWIN WILLIAMS
COLOR SW9141 WATERLOO
NOTES ACCENT
P-4 MFG SHERWIN WILLIAMS
COLOR SW7705 WHEAT PENNY
NOTES ACCENT
P-5 MFG SHERWIN WILLIAMS
COLOR SW2803 ROCKWOOD TERRA COTTA
NOTES ACCENT
P-6 MFG SHERWIN WILLIAMS
COLOR SW7041 VAN DYKE BROWN
NOTES EXPOSED INTERIOR STEEL
10 1400 DECORATIVE WINDOW FILM
WF-1 MFG 3M
PRODUCT CUSTOM GRADIENT WINDOW FILM
COLOR WHITE FROSTED
NOTES GRAPHIC PROVIDED BY ARCHITECT
10 2600 CORNER GUARDS (CG-X)
CG-1 MFG CONSTRUCTION SPECIALTIES, INC.
PRODUCT STAINLESS STEEL
SIZE 2" X 2" X 48"
COLOR SELECTED FROM MANUFACTURERS
FULL RANGE
NOTES 3/4" WING
12 3600 COUNTERTOPS (QZ-X)
QZ-1 MFG WILSONART
COLOR DESERT WIND Q4031
THICKNESS 2CM
NOTES LOBBY COUNTERTOP
12 3600 COUNTERTOPS (SS-X)
SS-1 MFG HI-MACS
COLOR NOBLE CANE W011
THICKNESS 1/2"
NOTES GENERAL COUNTERTOPS
SS-2 MFG HI-MACS
COLOR PORTLAND GT945
THICKNESS 1/2"
NOTES ACCENT COUNTERTOP
SS-3 MFG DURCON EPOXY RESIN
COLOR LUNAR WHITE
THICKNESS 2CM
NOTES LAB COUNTERTOPS
FINISH LEGEND
03 3000-D
09 6500 HEAT WELD SEAM
CARPET, SEE
FINISH SCHEDULE 09 6500
09 6500
SCHLUTER TRANSITION:
SCHIENE. FINISH: SATIN
ANODIZED ALUMINUM
MANUFACTURER'S STANDARD TRIM
INTEGRAL COVE FORMER
/6
SCHEDULED RESINOUS FLOORING
09 3000
SEALANT JOINT
09 3000
03 3000-D
09 6500
SCHLUTER TRANSITION: RENO RAMP.
FINISH: SATIN ANODIZED ALUMINUM
09 3000
FRYREGLET: DRYWALL REVEAL
DRM-50-50
FINISH:HAZE
/2
FREREGLET: WALL TILE REVEAL
MWR5050
FINISH: HAZE
/2
03 3000-D
09 6500
SCHLUTER TRANSITION: RENO-RAMP
FINISH: SATIN ANODIZED ALUMINUM
09 300009 2116-A
SCHLUTER TRANSITION: JOLLY
FINISH: SATIN ANODIZED ALUMINUM
09 3000
09 3000
03 3000-D
SCHLUTER TRANSITION:
RENO TK
FINISH: SATIN ANODIZED ALUMINUM
CARPET
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/2 /2
:5
:2
A M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A G
R
IC
U L
T U
R E
W A
Y L
A S
C R
U C
E S
N
E W
M E
X
IC
O
AF621
FINISH LEGEND
AND TRANSITION
DETAILS
MH
22-0227.001
EA
ISSUED FOR
CONSTRUCTION
10/09/2024
12" = 1'-0"E1
RESILIENT TO CARPET
12" = 1'-0"E2
RESILIENT TO RESINOUS
3" = 1'-0"D1
INTEGRAL COVE BASE
3" = 1'-0"D2
TILE FLOOR TO TILE WALL
12" = 1'-0"C1
TILE TO RESILIENT
12" = 1'-0"C2
DRYWALL REVEAL
12" = 1'-0"B2
WALL TILE REVEAL
12" = 1'-0"B1
RESILIENT TO CONCRETE
12" = 1'-0"A1
TILE CORNERS
12" = 1'-0"A2
TILE TO CARPET
2 11/22/2024 Addendum 006
F E
C
F E
C
F E
C
F E
C
FEC
F E
C
F E
C
FEC
F E
C
UP
A. ALL PLAN DIMENSIONS ARE TO FACE OF STUD OR CENTER OF COLUMN UNLESS
NOTED OTHERWISE.
B. REFER TO CIVIL FOR REFERENCE FINISH FLOOR ELEVATION.
C. REFER TO AF SHEETS FOR INTERIOR FINISH INFORMATION.
D. ALL WOOD BLOCKING, SHIMS AND PLYWOOD INSTALLED WITHIN WALL
ENCLOSURES TO BE FIRE RETARDANT.
E. REFER TO SHEET AE010 FOR PARTITION TYPES.
F. REFER TO SHEET AE121 FOR REFLECTED CEILING PLANS.
G. REFER TO BUILDING ELEVATIONS FOR LOCATIONS, TYPE, AND FINISH FOR ALL
EXTERIOR WALLS.
H. PROVIDE FIRE TREATED BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS.
I. LOCATE DOOR FRAMES / DOORS 4" FROM ADJACENT WALL.
J. PROVIDE BRACING AT DOOR FRAME LOCATIONS ON STRIKE SIDE AND PROVIDE
0.0312" THICK STEEL STUD AT DOOR STRIKE LOCATIONS.
K. PROVIDE VERTICAL CONTROL JOINTS IN GYPSUM BOARD PARTITIONS EVERY 30'-0"
MAXIMUM. ALIGN WITH DOOR FRAMES WHERE POSSIBLE.
L. COORDINATE LOCATION OF DATA AND ELECTRICAL ACCESS TO MODULAR
FURNITURE WITH OWNER.
M. ALL EXTERIOR GLAZING TO HAVE ROLLER SHADE SYSTEM, REFER TO OPENING
TYPES AE621, AE121A AND AE121B
N. PROVIDE TILE BACKING SUBSTRATE AT ALL LOCATIONS TO RECEIVE WALL TILE.
O. REFER TO FOOD SERVICE SHEETS FOR KITCHEN EQUIPMENT DRAWINGS.
P. REFER TO AE222 AND AE402 FOR LAB EQUIPMENT DRAWINGS.
Q. REFER TO ELECTRICAL DRAWINGS FOR IN FLOOR DEVICE LOCATIONS AT
CONFERENCE ROOMS.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
KEY PLAN
E5
A5 D5
C5
A5
AE201
C5
AE201
D5
AE201
RECORDING
MARKETING
STORAGE
RECYCLE
PUBLIC
AFFAIRS
STORAGE
134ACONTROL
CONF
STORAGE
WELLNESS
IT
STORAGE/BUILD
T156
411.43 SF
RETAINED
FILE
STORAGE
SERVER
T154
COPY / PRINT
DRY
STORAGE
157B
MECH
M180
S / R
BACK OF
TEST
KITCHEN
TEST
KITCHEN
157A
CONFERENCE
VESTIBULE
H100
CONFERENCE
HR
104G
DEP
DIRECTOR
104A
DIRECTOR
104B
OFFICE
104COFFICE
104D
OFFICE
104E
104F
STORAGE
JANITOR
J153
SHOWER
R155
RR
R143
RR
R141
RR
R140
RR
R138
RR
R127A
RR
R127B
LAB
OFFICE
112A
CONFERENCE
112B
OFFICE
112C
OFFICE
112D
OFFICE
112E
OFFICE
112F
OFFICE
112G
VESTIBULE
H164
BREAKROOM
HALLYWAY
H106
HALLWAY
H120
LOBBY
HALLWAY
H130
HALLWAY
H150
OPEN
OFFICE
HALLWAY
H165
OPEN
OFFICE
HH
HH
HH
HH
HH
HH
HH
J
H
J
M
J
J
H
A
A
A
AAAAAAA
B
AA
BB
CC
C
DD EE FF
N
AE221
D4
D5
H164B H164A
M
B
A
E
D
C
R A
R B
R
R
H
R
R
112A
112B
112C
112D
112E
112F
112G
T156
T154
R155
J153
H100A H100B 101A
136 125
123134A
AE402
C4
15'-2" 15'-3" 15'-1"
AE221E2
10'-4" 33'-4" 19'-2" 22'-6"
12'-0" 12'-0" 24'-0" 36'-10" 12'-0" 12'-0"
1'-0" 13'-4" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 17'-0" 7'-0" 29'-10" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 4'-9" 1'-0"
03A
06A
04A
04A
04A04A04A
04A04A 04A04A04A
04B
02A
02A
02A
04B
04B
04B
04B
04B
02B
04B
03A
03A
03B 03A
06A06B 04A06A 06A
03A03A 03B
06B
04B
13A03A05A 03A03A
03A 02A02A
03A 02A02A02B
19'-7" 9'-6" 7'-10" 1'-2"
06B 03B
13A
03B
06B
06B
06B
06B
13A
06B
13A
06B
13A
13A 02B
02A
02A
02A
06B
02A
04A
AE401
A5
DASH LINE DENOTES
GYP BOARD BRIDGE ABOVE
DASH LINE DENOTES
GYP BOARD BRIDGE ABOVE
AE402
A4
9'-2" 19'-7" 8'-10"
06B
TYP.
03A
06B
03A
03B
ABOVE
03A
03A
03A
03A
08 3313-C
E5
AE301
C5
AE301
A5
AE301
A2
AE302
A3
AE323
67"
DASH LINE DENOTES
GYP SOFFIT ABOVE
AE501
C2
AE501
A1
AE501
B5
AE501
C4
AE501
E3
AE501
A3
AE501
A4
AE501
B5
AE581
C3
SS
06A 06B
139C
ELEC
M180A
GG
AE221C5
AE221
C1
A A
C C
G G
L
L
D
D
E
H H
J
K xC xC x3
4 6
F
B B
G.7
G.5
152'-5"
16'-3"
06B
ABOVE
ABOVE
ABOVE
ABOVE
ABOVE
ABOVE
06B
06B
06B
06B
06B
R E
F E
R T
O A
E
D
O O
R T
Y P
E S
N A
N A
W A
L L
/1
SS
SS
SS 1
A
F
101B
AE223A1
AE221 E3
28 0000-A
139B
D
A4
AE323
A5
AE323
M A
E163
E121
ADMIN SUITE
4" 9"
02B02B
2 5.1
RR
AE582
A3
AE582
A3
TYP.
SIM.
AE561
C1
1'-3"
AE584
D3
AE501
A4
AE501
A4
AE501
A4
AE501
A4
AE501
A4
AE501
A4
AE501
A4
AE501
A4
AE501
A4
AE501
A4
AE582
D1
10 7316-A02
05 05
1'-0" 15'-2"
5'-2" 16'-9" 6'-0" 15'-4" 5'-2"
02A
04A
/4
10 562610 5626
TT1
B
TT
104G
09 8410-A
09 8410-A
09 8410-A
09 8410-A
JJ
A
AE501
A204BM11
04A
AE561
C2
A5
AE209
C5
AE209
D5
AE209
1'-3"
5"
139A
1'-3"
55"
1'-3"
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:2
:3
P
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE101A
FLOOR PLAN -
AREA A
SL
22-0227.001
CS, KK
ISSUED FOR
CONSTRUCTION
10/09/2024
NORTH
1/8" = 1'-0"A5
ENLARGED PLAN
NORTH
A
B
Existing Existing
08 3313-C SIDE ACTIVATED COILING DOOR
09 8410-A SOUND-ABSORBING UNITS, SA-3; BID LOT 3. CENTER ON WALL AND
MOUNT AT 36" AFF, UNLESS NOTED OTHERWISE.
10 5626 HIGH DENSITY SHELVING RECESSED RAILS. COORDINATE FINAL
PLACEMENT WITH OWNER AND ARCHITECT.
10 7316-A02 PRE-MANUFACTURED ALUMINUM WALKWAY CANOPY 1, REFER TO
A3/AE461
28 0000-A FIRE ALARM ANNUNCIATOR PANEL
05 PRINTER/COPIER, NIC
07 FUTURE ARTWORK. PROVIDE BLOCKING AS REQUIRED
2 11/22/2024 Addendum 006
3 12/05/2024 Addendum 007
A. DIMENSIONS ARE TO FINISHED FACE, UNLESS NOTED OTHERWISE.
B. SEE GI010 FOR TYPICAL ACCESSORY MOUNTING HEIGHTS.
C. PROVIDE BACKING FOR ATTACHING WALL MOUNTED ITEMS.
D. CENTER CASEWORK BETWEEN WALLS WITH NO MORE THAN 2” FILLER PANELS.
E. COORDINATE WALL ACCESS PANEL LOCATIONS AS TO NOT OVERLAP CHANGES IN
FINISHES.
F. ALIGN WALL TILE JOINTS WITH JOINTS IN FLOOR. AVOID USING LESS THAN HALF
THE WIDTH OF STANDARD TILES UNLESS OTHERWISE NOTED.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
ACCENT WALL TILE, REFERENCE FINISH LEGEND
SOUND ABSORBING WALL UNITS, SA-3.
SOUND ABSORBING WALL UNITS, SA-4.
A2
AE361
A1
AE361
5'-0"
12 3600-E
06 4100-B16
09 3000-L
06 4100-B16
A2
AE361
A1
AE361
170"
48" 124" 06 4100-B16
12 3600-E
06 4100-B16
09 3000-L
09 3000-A
10 1400-D
EQ. EQ.
QUARTZ SEAM
LAMINATE SEAM
92"
A2
AE361
A1
AE361
24"
A5
AE361
09 6500-A
06 4100-B22
90 1/2"
06 4100-B01
12 3600-B01
12 3600-B02
C1
AE361
A3
AE361
D4
AE362
06 4100-B03
06 4100-B03
09 3000-B
09 6500-A
C5
AE361
36" 18"24"36"36"36"9"28"
48" 48"EQ. EQ.
06 4100-B01
6"
11 3013-H
11 3013-B
11 3013-C
MODIFY CASEWORK SHELVING
TO ACCOMMODATE RO SYSTEM
24"
09 7200-A
06 4100-L01
09 3000-B
06 4100-L02
D1
AE361
D2
AE361
D4
AE361
C4
AE361
18"24" 18" 24"
06 4100-B19
09 7200-A
06 4100-B01
C3
AE361
D3
AE361
06 4100-B01
12 3600-B01
06 4100-B01
06 4100-B01
4" 139"4"4" 70"119 1/2"
190 1/2"
12 3600-B01
11 3013-F 11 3013-A01
36"36"
12 3600-B01
06 4100-B22
09 6500-A
C1
AE361
1'-6"
TYP.
36"36"
C1
AE361
D5
AE361
06 4100-B22
09 6500-A
12 3600-B01
36"36"24"
12 3600-B01
C1
AE361
D5
AE361
34"36"
12 3600-B01
06 4100-B02
D4
AE362
C1
AE361
06 4100-B01
11 3013-A03
33"
06 4100-B04
09 3000-K
06 4100-B02
50"
06 4100-B02
09 6500-A
A4
AE361
MIN. OPENING
25"
A4
AE362
A2
AE362
A3
AE362
2 3/8" 37 3/4"
36"36"36"2" 21"
PULL
OUT
TRASH
21" 18" 18"36"
06 4100-B01
48"
12 3600-B01
C5
AE362
A5
AE362
B5
AE362
D5
AE362
166 1/2"
11 3013-E01
09 6500-A
166 1/2"
09 3000-K
12 3600-B01
10 1400-D
11 3013-E01
E Q
E Q
EQ.EQ.
A2
AE361
30"
A1
AE361
09 3000-L06 4100-B16
06 4100-M
(3) UNITS
96"
C3
AE361
32"
09 6500-B
109"
12 3600-B02
06 4100-B01
09 6500-A
12 3600-B01
3"
E5
AE362
D5
AE362
EQ.
09 8430-C
09 8430-C 09 6500-A
EQ.EQ.EQ.
C3
AE362
(3) UNITS
96" 32"
06 4100-M
06 4100-B22
12 3600-B01
09 6500-A
C2
AE361
24"
OPEN
36"
D5
AE361
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/2 /2
:0
:4
A M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE221
INTERIOR
ELEVATIONS
SL
22-0227.001
EA, KL
ISSUED FOR
CONSTRUCTION
10/09/2024
1/4" = 1'-0"A5
INTERIOR ELEVATION
1/4" = 1'-0"A4
INTERIOR ELEVATION
1/4" = 1'-0"A3
INTERIOR ELEVATION
1/4" = 1'-0"A1
INTERIOR ELEVATION
1/4" = 1'-0"C2
INTERIOR ELEVATION
1/4" = 1'-0"C3
INTERIOR ELEVATION
1/4" = 1'-0"D5
INTERIOR ELEVATION
1/4" = 1'-0"D4
INTERIOR ELEVATION
1/4" = 1'-0"D3
INTERIOR ELEVATION
1/4" = 1'-0"C5
INTERIOR ELEVATION
06 4100-B01 PLASTIC LAMINATE, PL-1
06 4100-B02 PLASTIC LAMINATE, PL-3
06 4100-B03 2" PLASTIC LAMINATE FRAME WITH GLASS INSERT, PL-1
06 4100-B04 2" PLASTIC LAMINATE FRAME WITH GLASS INSERT, PL-3
06 4100-B16 PLASTIC LAMINATE, PL-4. MITER FOLD LAMINATE OVER SUBSTRATE
PER MANUFACTURES INSTRUCTIONS
06 4100-B19 PLASTIC LAMINATE PANEL TO WRAP CORNERS TO BACK WALLS
06 4100-B22 PLASTIC LAMINATE, PL-2
06 4100-L01 UPHOLSTERED CUSHION, F-1
06 4100-L02 UPHOLSTERED CUSHION, F-2
06 4100-M DOUBLE SIDED CUSTOM DISPLAY CASE; SEE SPECIFICATIONS
09 3000-A WALL TILE, T-1; LARGE FORMAT TILE
09 3000-B WALL TILE, T-3
09 3000-K WALL TILE, T-11
09 3000-L WALL TILE BASE, TA-1
09 6500-A RESILIENT BASE; RA-1
09 6500-B RESILIENT BASE, RA-2
09 7200-A WALL COVERING, WC-1;
09 8430-C SOUND-ABSORBING UNITS, SA-3; BASE BID
10 1400-D DIMENSIONAL LETTER, SIGNAGE
11 3013-A01 REFRIGERATOR
11 3013-A03 REFRIGERATOR, UNDER-COUNTER
11 3013-B ICE MAKER
11 3013-C COFFEE BREWER
11 3013-E01 RANGE HOOD, VENTED TO EXTERIOR
11 3013-F MICROWAVE OVEN
11 3013-H DISHWASHER
12 3600-B01 SOLID SURFACE, SS-1
12 3600-B02 SOLID SURFACE, SS-2; 3" THICK EDGE W/ WATERFALL EDGE AND
TUBE STEEL FRAME.
12 3600-E QUARTZ COUNTERTOP, QZ-1
1/4" = 1'-0"B3
INTERIOR ELEVATION
1/4" = 1'-0"B2
INTERIOR ELEVATION
1/4" = 1'-0"B1
INTERIOR ELEVATION
04 APPLIANCE, NIC
05 PRINTER/COPIER, NIC
1/4" = 1'-0"A2
INTERIOR ELEVATION
1/4" = 1'-0"E2
INTERIOR ELEVATION
1/4" = 1'-0"C1
INTERIOR ELEVATION
1/4" = 1'-0"E3
INTERIOR ELEVATION
1/4" = 1'-0"B5
INTERIOR ELEVATION
DISPLAY CASE RENDERING
FOR REFERENCE ONLY
PARTITION TYPE LEGEND
PARTITION NUMBER (UNO):
METAL FRAMING
0's = FULL HEIGHT TO STRUCTURE 10's = PARTIAL HEIGHT (6" ABOVE CEILING UNO) 20's = FIRE RATED 30's = FIRE RATED (CT STUDS) 40's = ACOUSTIC RATED
WOOD FRAMING
50's = FULL/PARTIAL HEIGHT 60's = FIRE RATED 70's = ACOUSTIC RATED 80's = DEMISING 90's = CUSTOM
A = 3 5/8" (4" CT) / 2x4 B = 6" / 2x6 C = 8" / 2X8
D-Z = OTHER SIZES ASSIGNED
12A
STUD SIZE:
NOTE:
SEE PARTITION TYPES THIS SHEET FOR MORE DETAILED ASSEMBLY INFORMATION
PARTITION GENERAL NOTES
PARTITIONS NOTED WITH ACOUSTICAL INSULATION, THE FOLLOWING NOTES
APPLY:
1. GYPSUM BOARD IS 5/8", TYPE 'X' UNLESS NOTED.
2. FOR PARTITION TYPES AT HEADERS, DOORS, GLAZING, AND FOR CASED
OPENINGS, CONTINUE ADJACENT PARTITION TYPE, UNLESS NOTED OTHERWISE.
3. PENETRATIONS OF THE WALL SHALL BE SEALED AIRTIGHT AT FLOOR, SIDES,
CEILING, AND ON BOTH SIDES WITH ACOUSTICAL SEALANT. THE CAVITY IN
BETWEEN THE PENETRATION SHALL BE FILLED WITH LOOSE FIBERGLASS.
4. FIRE-RATED PUTTY PADS ARE REQUIRED ON WALL OUTLET BOXES FOR
POWER, DATAM VOICE, VIDEO, OR OTHER UTILITIES MOUNTED WITHIN 24" OF
OTHER BOXES MOUNTED ON OTHER SIDES OF STUD WALLS. SEAL FRONT OF
BOXES AIRTIGHT.
5. WHERE TWO OR MORE LAYERS OF GYPSUM ARE SPECIFIED ON ONE OR BOTH
SIDES OF A PARTITION, STAGGER THE JOINTS, SCREW GYPSUM LAYERS TO THE
STUD, AND TAPE, SAND, AND SEAL GYPSUM LAYERS SEPARATELY. FINAL LAYOUT
TO BE TAPED AND SANDED SMOOTH FOR THE ARCHITECTURAL FINISH.
6. ACOUSTICAL SEALANT BEADS SHALL BE MANUFACTURED BY USG OR TREMCO.
PROVIDE A CONTINUOUS SEALANT BEAD AT THE ENTIRE PERIMETER OF THE
ASSEMBLY, TYPICAL.
1/2"
ACOUSTICAL SEALANT
*MATCH FIRE RATING OF WALL
ACOUSTIC INSULATION
BETWEEN METAL STUDS
AT ACOUSTICAL
PARTITION
EXPANSION
(CONTROL) JOINT
GYPSUM BOARD
METAL STUDS
AS SPECIFIED
GYPSUM BOARD METAL STUDS
AS SPECIFIED
DOOR FRAME BELOW
1/2"
ACOUSTIC INSULATION
BETWEEN METAL STUDS
AT ACOUSTICAL
PARTITION
EXPANSION (CONTROL)
JOINT
GYPSUM BOARD
METAL STUDS
AS SPECIFIED
AT DOOR ALONG WALL
CONTROL JOINTS SHOWN ON DETAILS ARE TYP. DO NOT LOCATE CONTROL JOINTS AT EVERY JOINT
LOCATION SHOWN ON DETAILS. CONTROL JOINT REQ. TO BE LESS THAN 30' APART.
/4
WIDTH VARIES
STUD WALL
1" MIN.
PARALLEL TO FLUTEPERPENDICULAR TO FLUTE
/8
/8
MINERAL WOOL IN FLUTE
CAVITY
FLUTED METAL DECK WITH
CONCRETE FILL
0.145"X1" POWER ACTUATED
FASTENER @ 16" O.C.
MAXIMUM, TYPICAL
REFERENCE FASTENERS
MANUFACTURER ICBO FOR
FASTENER CAPACITY
2" X 20 GA STEEL STRAP OR
Z-BARS @ 16" O.C. MAXIMUM
CONTINUOUS
ACOUSTICAL SEALANT
#8 WAFER HEAD FRAMING
SCREWS
SLOTTED TRACK
SOUND ATTENUATION
BLANKET
ACOUSTICAL SEALANT
#8 WAFER HEAD FRAMING
SCREWS
SLOTTED TRACK
SOUND ATTENUATION
BLANKET
MINERAL WOOL IN FLUTE
CAVITY
NOTE:
1. DO NOT SCREW DRYWALL TO SLOTTED TRACK
STRUCTURE
WIDTH VARIES
STUD WALL
4" x 16 GAUGE BENT METAL
PLATE, ATTACH TO DECK WITH 2
POWDER-DRIVEN FASTENERS AT
COMPOSITE DECKS AND WITH #
10 SHEET METAL SCREWS AT
METAL DECKS ONLY
O
R G
R E
A T
E R
/2
1"
RUNNER TRACK TO MATCH
SIZE AND GAUGE OF VERTICAL
STUD FRAMING, ATTACH TO
DECK AT 24" OC AND 2" FROM
ENDS. USE POWDER-DRIVEN
FASTENERS AT COMPOSITE
DECKS AND #10 SHEET METAL
SCREWS AT METAL DECKS
ONLY
3/4" #10 SHEET
METAL SCREWS
TYPICAL OF FOUR
EACH END
CEILING WHERE OCCURS
3-5/8" x 20 GAUGE METAL
STUD UNLESS STUD OF
ANOTHER DEPTH IS NOTED
OR REQUIRED TO MATCH
ADJACENT FLOOR
SUPPORTED STUDS
ONE LAYER OF 5/8"
GYPSUM BOARD WHERE
EXPOSED UNLESS NOTED
OTHERWISE
CONTINUOUS 20GA
TRACK.
MINIMUM 3 SPANS
BETWEEN SPLICES
5/8" GYPSUM BOARD
UNLESS NOTED OTHERWISE
STEEL STUD, 3-5/8", - SEE
PARTITION TYPES FOR
GAUGE AND SPACING
L3" X 3" X 3/16" X 2'0"
WELDED TO PLATE
WITH 3/16" WELD
LOCATE AT MAXIMUM
OF 4' O.C., AT
CORNERS, AND AT
WALL ENDS
5/8" GYPSUM
BOARD
UNLESS NOTED
OTHERWISE
CONCRETE SLAB
PL 3/8" X 3" X 6" WITH
TWO(2) 1/2" X 3-1/2"
EXPANSION ANCHORS.
LOCATE AND AVOID
REINFORCEMENT,
POST TENSIONED
STRANDS, STEEL
BEAMS, ETC. BEFORE
INSTALLING
EXPANSION ANCHORS.
#10 SELF DRILLING
SCREWS AT 4" O.C.
OFFSET
PENETRATIONS ON
OPPOSITE SIDES,
ONE STUD SPACE,
TYP.
ACOUSTI
C
INSULATI
ON
ACOUSTIC SEALANT ALL
AROUND PENETRATION,
TYP.
ACOUSTIC BOX,
TYP.
NO MORE THAN ONE
SIDE CAN BE
PENETRATED IN A
GIVEN STUD SPACE
PARTITION AS
SCHEDULED
TYPICAL CONNECTION:
CUT FLANGES FROM WEB
AND BEND WEB UP FACE OF
STUD. PROVIDE TWO 3/4" #10
PAN HEAD SHEET METAL
SCREWS. LOCATE SCREWS
1/2" UP FROM WEB AND 3/4" IN
FROM EACH END OF BENT
WEB
OPENINGS UP TO 3'-6" WIDE OPENINGS 3'-6" TO 8'-0" WIDE OPENINGS 8'-0" TO 12'-0" WIDE
DOUBLE 20 GAUGE METAL
STUDS TO STRUCTURE
CONTINUOUS RUNNER TRACK
DEPTH OF TRACK TO MATCH
DEPTH OF VERTICAL STUDS
AS INDICATED BY PARTITION
TYPE ON FLOOR PLANS
TYPICAL ALL HEAD TYPES
DOUBLE 20 GAUGE METAL
STUDS TO STRUCTURE
CONTINUOUS RUNNER TRACK
ATTACHED TO NESTED STUD
EXTEND RUNNER TRACK
FLANGES 1 5/8" MIN EACH SIDE
BEYOND FACE OF JAMB.
PROVIDE 3/4" LOW PROFILE #10
PAN HEAD SHEET METAL
SCREWS EACH SIDE
DOUBLE 20 GAUGE METAL
STUDS TO STRUCTURE
EXTEND RUNNER TRACK
FLANGES 1 5/8" MIN EACH SIDE
BEYOND FACE OF JAMB.
PROVIDE 3/4" LOW PROFILE #
10 PAN HEAD SHEET METAL
SCREWS EACH SIDE
CONTINUOUS METAL STUD
NESTED INTO BOTTOM
RUNNER TRACK
CONTINUOUS RUNNER TRACK
ATTACHED TO DOUBLE STUD
TWO CONTINUOUS 4" METAL
STUDS TURNED ON EDGE
AND NESTED INTO BOTTOM
RUNNER TRACK
NON-STRUCTURAL METAL FRAMING
DOORS
RUNNER TRACK AT
UNDERSIDE OF
CONSTRUCTION
CEILING LINE
DOUBLE 20 GAUGE
METAL STUDS TO
STRUCTURE AT JAMBS
AT ALL PARTITIONS,
INCLUDING CEILING
HEIGHT PARTITIONS
20 GAUGE METAL STUD 6"
FROM JAMB TYP BOTH
SIDES
RUNNER TRACK AT
FINISHED FLOOR
RUNNER TRACK AT
UNDERSIDE OF
CONSTRUCTION
CEILING LINE
20 GAUGE HEAD TRACK
DOUBLE 20 GAUGE
METAL STUDS TO
STRUCTURE AT JAMBS
AT ALL PARTITIONS,
INCLUDING CEILING
HEIGHT PARTITIONS
20 GAUGE SILL TRACK
RUNNER TRACK AT
FINISHED FLOOR
CEILING LINE
DIAGONAL KNEE BRACE
WHERE HEIGHT OF
SUSPENDED PARTITION
EXCEEDS 2'-0" ABOVE
LOWEST ADJACENT CEILING
STEEL ANGLE SUPPORTS
4'-0" OC MAX
4'-0" OC MAX
GLAZED OPENINGS / PASS-THROUGHS SUSPENDED AND PARTIAL HEIGHT PARTITIONS
ADDITIONAL STUD AT
CONTROL JOINT LOCATIONS
(WHERE OCCURS)
NON-STRUCTURAL METAL FRAMING
SEE DETAIL A4 THIS SHEET
SEMI-RECESSED FIRE
EXTINGUISHER CABINET
(WITH FIRE
EXTINGUISHER 2A-10BC),
INSTALL AS PER
MANUFACTURER
RECOMMENDATIONS
METAL STUD,
RE: FLOOR
PLANS FOR
PARTITION
TYPE
BATT INSULATION 5/8" GYP.BD., RE
FLOOR PLANS FOR
PARTITION TYPE
M A
N U
F
A S
P E
R
NOTE: MOUNT AT 48" A.F.F.
(MAXIMUM) TO CENTER LINE
OF OPERATING LATCH
/4
1" MIN.
PARALLEL TO FLUTEPERPENDICULAR TO FLUTE
/8
/8
FLUTED METAL DECK
0.145"X1" POWER ACTUATED
FASTENER @ 16" O.C.
MAXIMUM, TYPICAL
REFERENCE FASTENERS
MANUFACTURER ICBO FOR
FASTENER CAPACITY
2" X 20 GA STEEL STRAP OR
Z-BARS @ 16" O.C. MAXIMUM
CONTINUOUS
#8 WAFER HEAD FRAMING
SCREWS
SLOTTED TRACK
SOUND ATTENUATION
BLANKET
#8 WAFER HEAD FRAMING
SCREWS
SLOTTED TRACK
SOUND ATTENUATION
BLANKET
NOTE:
1. DO NOT SCREW DRYWALL TO SLOTTED TRACK
WITDH VARIES
STUD WALL
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:0
:1
A
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE010
PARTITION
TYPES, AND
TYPICAL DETAILS
SL
22-0227.001
CS, KK
ISSUED FOR
CONSTRUCTION
10/09/2024
PARTITION TYPE SCHEDULE
TYPE
MARK
TYPE IMAGE
WALL ASSEMBLY
02A
FULL HEIGHT
● 5/8" GYPSUM BOARD
■ 3 5/8" METAL STUDS
● 5/8" GYPSUM BOARD
TOTAL WIDTH:4 7/8"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
02B
FULL HEIGHT
● 5/8" GYPSUM BOARD
■ 6" METAL STUDS
● 5/8" GYPSUM BOARD
TOTAL WIDTH:7 1/4"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
02C
FULL HEIGHT
● 5/8" GYPSUM BOARD
■ 6" METAL STUDS, 6" METAL STUDS
● 5/8" GYPSUM BOARD
TOTAL WIDTH:1'-1 1/4"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
03A
FULL HEIGHT
▫ STC 50
● 5/8" QUIET ROCK
■ 3 5/8" METAL STUDS
● 5/8" QUIET ROCK
● 5/8" QUIET ROCK
TOTAL WIDTH:5 1/2"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
03B
FULL HEIGHT
▫ STC 50
● 5/8" QUIET ROCK
■ 6" METAL STUDS
● 5/8" QUIET ROCK
● 5/8" QUIET ROCK
TOTAL WIDTH:7 7/8"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
03C
FULL HEIGHT
▫ STC 50
● 5/8" QUIET ROCK
■ 8" METAL STUDS
● 5/8" QUIET ROCK
● 5/8" QUIET ROCK
TOTAL WIDTH:9 7/8"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
04A
FULL HEIGHT
● 5/8" GYPSUM BOARD
■ 3 5/8" METAL STUDS
TOTAL WIDTH:4 1/4"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
04B
FULL HEIGHT
● 5/8" GYPSUM BOARD
■ 6" METAL STUDS
TOTAL WIDTH:6 5/8"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
05A
FULL HEIGHT
● 5/8" QUIET ROCK
■ 3 5/8" METAL STUDS
TOTAL WIDTH:4 7/8"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
06A
FULL HEIGHT
▫ STC 45
● 5/8" GYPSUM BOARD
■ 3 5/8" METAL STUDS
● 5/8" GYPSUM BOARD
● 5/8" GYPSUM BOARD
TOTAL WIDTH:5 1/2"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
06B
FULL HEIGHT
▫ STC 45
● 5/8" GYPSUM BOARD
■ 6" METAL STUDS
● 5/8" GYPSUM BOARD
● 5/8" GYPSUM BOARD
TOTAL WIDTH:7 7/8"
COMMENTS:EXTEND TO UNDERSIDE OF DECK ABOVE
13A
PARTIAL HEIGHT
● 5/8" GYPSUM BOARD
■ 3 5/8" METAL STUDS
TOTAL WIDTH:4 1/4"
COMMENTS:FURROUT PARTITION. TOP OF WALL 6" ABOVE HIGHEST
ADJACENT CEILING. STAGGERED DIAGONAL BRACING AT MAX 4 FT
OC, FROM TOP OF PARTITION TO STRUCTURE ABOVE IF REQUIRED
6" = 1'-0"E1 TYPICAL CONTROL JOINTS
3" = 1'-0"D1 ACOUSTIC HEAD OF WALL (HORIZONTAL)
1 1/2" = 1'-0"C3 SUSPENDED / PARTIAL HEIGHT PARTITION
3" = 1'-0"D4 ACOUSTICAL PARTITION - STAGGERED BOXES
1 1/2" = 1'-0"B1 TYPICAL FRAMING DETAILS- HEAD AND JAMB
1/4" = 1'-0"A1 TYPICAL FRAMING DETAILS
3" = 1'-0"B4 FIRE EXTINGUISHER CABINET
3" = 1'-0"C1 HEAD OF WALL (HORIZONTAL)
VARIES
LEVEL 1
SEE PLAN
VARIES
LEVEL 1
A. XX.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
T.O. STOREFRONT
111'-4"
1 2
4 1/2"
07 2500-A
WATER-RESISTIVE
BARRIER
07 4213.23-A
METAL COMPOSITE
MATERIAL PANEL -
DRY JOINT SYSTEM
05 4000-A
METAL STUD
08 3223
SLIDING AND
FOLDING GLAZED
WALLS AND DOORS
08 4313-C
ALUMINUM BRAKE
METAL TRIM
05 4000-A
METAL STUD
07 5400-E
COVER BOARD
26 0000-A
LIGHT FIXTURE
T.O. CW 6
111'-4"
09 2116-A
GYPSUM BOARD TO DECK
07 9200-A
SEALANT
07 3113-D01
PREMANUFACTURED
ALUMINUM FLASHING
TO MATCH METAL
PANEL
07 3113-D01
PREMANUFACTURED
ALUMINUM FLASHING
TO MATCH METAL
PANEL
2" OPENING CONCEALED
CONDUIT PATH
1'-3" 2
F
1 2
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
07 9200-B
BACKER ROD AND
SEALANT
08 3223
SLIDING AND
FOLDING GLAZED
WALLS AND DOORS
07 4213.23-A
METAL COMPOSITE
MATERIAL PANEL -
DRY JOINT SYSTEM
08 4413-A
GLAZED ALUMINUM
CURTAIN WALL
SYSTEM, CLEAR
ANODIZED07 5400-E
COVER BOARD
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
05 4000-A
METAL STUD
05 4000-B
METAL TRACK
1'-3"
32 0000-A
03 3000-G
03 0516-A
07 9200-C
08 4313-A
03 3000-D
07 9200-A
GRID
1 1/2"
06 1000-A
07 9200-B
08 4313-F
07 9200-B
08 4413-A
09 2116-G
GRID
/2
07 9200-C
M11
07 2119-C
07 9200-B
08 4413-A
07 9200-C
M11
07 2119-C
GRID
/2
/2
09 2116-C
SLAB EDGE
07 9200-B
08 4413-A
07 9200-C
M11
07 2119-C
/2
GRID
09 2116-C
08 4313-A
07 9200-B
07 9200-C
M11
GRID
07 2400-G
12 2400-D
1 1/2"2 5/8"
07 9200-B
08 4313-A
07 9200-C
07 2119-C
09 2116-G
M11
/2
/2
GRID
07 2400-G
07 2400-F
06 1000-B01
06 1000-A01
S11
M11
07 2400-G
07 9200-A
EMBED THE
SHEATHING
FABRIC IN WRB
COATING
EMBED THE
SHEATHING
FABRIC IN WRB
COATING
1'-8"
M11
S11
M11
SEE PLAN
07 9200-B
12 2400-D
AE521
E5
32 0000-A
03 3000-G
03 0516-A
07 9200-A
M11
GRID
1'-0" 07 2500-A
07 9200-B
07 2500-D
3" = 1'-0"D3
CURTAIN WALL AT OVERHANG
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:2
:5
P
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE582
WINDOW DETAILS
SL
22-0227.001
CS, KK
ISSUED FOR
CONSTRUCTION
10/09/2024
03 0516-A UNDER-SLAB VAPOR RETARDER
03 3000-D CONCRETE SLAB
03 3000-G EXPANSION/ISOLATION JOINT
05 4000-A METAL STUD
05 4000-B METAL TRACK
06 1000-A WOOD SHIM
06 1000-A01 WOOD SHIM, FIRE RETARDANT TREATED
06 1000-B01 WOOD NAILER, FIRE RETARDANT TREATED
07 2119-C WINDOW AND DOOR FILLER FOAM
07 2400-F WATER-RESISTIVE BARRIER
07 2400-G EIFS BACKWRAPPED
07 2500-A WATER-RESISTIVE BARRIER
07 2500-D BUTYL TAPE
07 3113-D01 PREMANUFACTURED ALUMINUM FLASHING TO MATCH METAL PANEL
07 4213.23-A METAL COMPOSITE MATERIAL PANEL - DRY JOINT SYSTEM
07 5400-E COVER BOARD
07 9200-A SEALANT
07 9200-B BACKER ROD AND SEALANT
07 9200-C CAULK
08 3223 SLIDING AND FOLDING GLAZED WALLS AND DOORS
08 4313-A ALUMINUM-FRAMED STOREFRONT SYSTEM, CLEAR ANODIZED
08 4313-C ALUMINUM BRAKE METAL TRIM
08 4313-F HIGH PERFORMANCE SILL FLASHING WITH GASKET
08 4413-A GLAZED ALUMINUM CURTAIN WALL SYSTEM, CLEAR ANODIZED
09 2116-A GYPSUM BOARD
09 2116-C METAL STUD, SEE PARTITION TYPES
09 2116-G CORNER BEAD
12 2400-D MANUAL SHADE / 3% OPENING SLIM LINE SURFACE MOUNTED BRACKET
WITH FASCIA SHADE CLOTH .015" THICK. COLOR: WHITE
26 0000-A LIGHT FIXTURE
32 0000-A CONCRETE SIDEWALK
3" = 1'-0"A3
NANA WALL JAMB AND CURTAIN WALL AT METAL PANEL
3" = 1'-0"C4
NANA WALL SILL AND TRACK
3" = 1'-0"A2
BASE AT FINISH GRADE
3" = 1'-0"B1
CURTAIN WALL JAMB
3" = 1'-0"C1
CURTAIN WALL JAMB
3" = 1'-0"D1
CURTAIN WALL JAMB
3" = 1'-0"D2
STOREFRONT HEAD
3" = 1'-0"C2
STOREFRONT JAMB
3" = 1'-0"E2
EIFS @ SOFFIT
1 1/2" = 1'-0"E1
CEILING DETAIL
3" = 1'-0"A1
BASE AT FINISH GRADE EIFS
VARIES
LEVEL 1
SEE PLAN
SEE PLAN
SEE PLANSEE PLAN
SEE PLAN
SEE PLAN
SEE PLAN
VARIES
LEVEL 1
32 0000-A
03 3000-G
03 0516-A
07 9200-B
03 3000-D
07 9200-A
08 4413-A
GRID
1'-3"
07 9200-C
06 1000-A01
GRID
GRID
08 4413-I
08 4413-H
08 4413-G
1'-3"
"08 4413-A
A. XX.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
07 9200-B
08 4313-A
07 9200-C
07 2119-C
M41
09 2116-G
/2
GRID
T
Y P
06 1000-A01
06 1000-B01
M41
M41
07 4213-A02
ALIGN JAMB TRIM
WITH SILL TRIM
BELOW
07 9200-B
08 4313-A
07 9200-C
07 2119-C
M41
/2
GRID
T
Y P
06 1000-A01
06 1000-B01
07 2100-B01
M41
07 9200-B
05 4000-D
07 9200-C
07 2119-A
08 4313-A
GRID
1'-0" TYP. 1/2"
07 6200-I
2 5/8"
12 2400-D
M41
08 4313-A
07 9200-C
07 9200-B
07 4213-A06
07 4213-A05
1'-0" TYP. 1/2"
GRID
06 1000-B01
06 1000-A01
07 2100-B01
M41
08 4313-A
07 9200-C
07 9200-B
07 4213-A06
07 4213-A05
GRID
1'-0"
1 1/2"
1'-0"
06 1000-D02
/2
06 1000-B01
S41
07 9200-B
05 4000-D
07 9200-C
07 2119-A
08 4313-A
GRID
07 9200-A
07 6200-I
12 2400-E
1 1/2"
S41
M41
07 6200-I
07 2119-C
E103
07 9200-B
08 4413-A
07 9200-C
/2
T
Y P
M41
GRID
06 1000-A01
06 1000-B0107 2100-B01
M41
07 9200-B
05 4000-D
07 9200-C
07 2119-A
08 4413-A
1'-0" TYP. 1/2"
GRID
12 2400-B
07 6200-I
M41
07 9200-B
05 4000-D
07 9200-C
07 2119-A
08 4313-A
GRID
1'-0" TYP. 1/2"
12 2400-E 07 6200-I
07 9200-B
08 4313-A
07 9200-C
07 2119-C
M41
09 2116-G
/2
/2
/2
G R
ID
07 6200-I
ALIGN JAMB TRIM
WITH SILL TRIM
BELOW
07 9200-A
07 2500-A
SLAB EDGE
BELOW
1/2"
S41
05 4000-D
07 2119-A
GRID
1'-0" 1/2"
07 9200-A
07 6200-I
07 9200-B
6"
M41
07 9200-B
07 9200-C
08 4313-A
GRID
1'-0" 1'-0" TYP. 1/2"
12 2400-B
05 1200-E
07 6200-I
S41
05 4000-D
07 2119-A
GRID
1'-0" 1/2"
07 9200-A
07 6200-I
07 9200-B
06 1000-B01
3 1/2" 6"
09 5100-A
12 2400-C
32 0000-A
03 3000-G
03 0516-A
07 9200-A
M41
GRID
1'-0"
M A
X
07 6200-I
07 2500-A
07 2500-D
08 4313-A
07 9200-C
07 9200-B
07 4213-A05
07 4213-A06
M41
1'-0" 1/2"
GRID
06 1000-B01
06 1000-A01
07 2100-B01
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:2
:5
P
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE581
WINDOW DETAILS
SL
22-0227.001
CS, KK
ISSUED FOR
CONSTRUCTION
10/09/2024
3" = 1'-0"A3 BASE AT FINISH GRADE
3" = 1'-0"C3
CURTAIN WALL CORNER
03 0516-A UNDER-SLAB VAPOR RETARDER
03 3000-D CONCRETE SLAB
03 3000-G EXPANSION/ISOLATION JOINT
05 1200-E STEEL BRACED FRAMING
05 4000-D METAL STUD BUILT-UP LINTEL
06 1000-A01 WOOD SHIM, FIRE RETARDANT TREATED
06 1000-B01 WOOD NAILER, FIRE RETARDANT TREATED
06 1000-D02 CONTINUOUS BLOCKING
07 2100-B01 BLANKET INSULATION - R19 (IN-01)
07 2119-A FOAMED-IN-PLACE INSULATION (IN-05)
07 2119-C WINDOW AND DOOR FILLER FOAM
07 2500-A WATER-RESISTIVE BARRIER
07 2500-D BUTYL TAPE
07 4213-A02 PREFINISHED METAL OUTSIDE CORNER TRIM
07 4213-A05 PREFINISHED METAL WALL PANEL SUPPORT Z
07 4213-A06 PREFINISHED METAL WALL PANEL WINDOW SILL TRIM
07 6200-I PREFINISHED METAL TRIM ASSEMBLY, COLOR TO MATCH METAL
PANEL
07 9200-A SEALANT
07 9200-B BACKER ROD AND SEALANT
07 9200-C CAULK
08 4313-A ALUMINUM-FRAMED STOREFRONT SYSTEM, CLEAR ANODIZED
08 4413-A GLAZED ALUMINUM CURTAIN WALL SYSTEM, CLEAR ANODIZED
08 4413-G ALUMINUM GLAZING FRAME
08 4413-H BACKER ROD AND STRUCTURAL SILICONE WEATHER SEAL SEALANT
08 4413-I STRUCTURAL SILICONE ADHESIVE AND GASKET
09 2116-G CORNER BEAD
09 5100-A ACOUSTICAL CEILING SYSTEM, AC-1
12 2400-B MOTORIZED SHADE / 3% OPENING STANDARD SURFACE MOUNTED
BRACKET WITH FASCIA SHADE CLOTH .3" THICK. COLOR: WHITE
12 2400-C MOTORIZED SHADE DUAL ROLLER / BLACKOUT AND SHADE / 3%
OPENING. COLOR: WHITE
12 2400-D MANUAL SHADE / 3% OPENING SLIM LINE SURFACE MOUNTED
BRACKET WITH FASCIA SHADE CLOTH .015" THICK. COLOR: WHITE
12 2400-E MOTORIZED SHADE DUAL ROLLER / BLACKOUT AND SHADE / 3%
OPENING. COLOR: MATCH METAL PANEL
32 0000-A CONCRETE SIDEWALK
3" = 1'-0"C2
STOREFRONT JAMB
3" = 1'-0"E2
STOREFRONT JAMB
3" = 1'-0"C1
STOREFRONT JAMB
3" = 1'-0"D1
STOREFRONT HEAD
3" = 1'-0"B1
STOREFRONT SILL
3" = 1'-0"A4
STOREFRONT SILL
3" = 1'-0"B4
STOREFRONT HEAD
3" = 1'-0"B5
METAL PANEL SOFFIT
3" = 1'-0"B3
CURTAIN WALL JAMB
3" = 1'-0"D4
CURTAIN WALL HEAD
3" = 1'-0"D2
STOREFRONT HEAD
3" = 1'-0"E3
STOREFRONT JAMB
3" = 1'-0"D3
CURTAIN WALL HEAD
3" = 1'-0"C4
STOREFRONT HEAD
3" = 1'-0"E4
CURTAIN WALL HEAD
3" = 1'-0"A2
BASE AT FINISH GRADE
3" = 1'-0"B2
STOREFRONT SILL
A. SEE AE090 FOR EXTERIOR WALL, SOFFIT AND ROOF ASSEMBLIES.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
M41
RF41
1'-0"
07 6200-E
PRE-MANUFACTURED
METAL DOWNSPOUT,
COLOR TO MATCH
METAL WALL PANEL
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
07 4113-H
FLASHING
07 4213-A04
PREFINISHED METAL
J TRIM
RF11
M41
07 4213-A03
PREFINISHED METAL
DRIP FLASHING
07 9200-B
BACKER ROD AND
SEALANT
07 5400-L
6" HIGH 20 GAUGE
GALVANIZED STRAP
07 5419-A
(PVC) MEMBRANE
ROOF SYSTEM
07 5400-D
METAL TERMINATION
BAR
1'-0"
06 1000-C02
PLYWOOD, FIRE
RETARDANT TREATED
3/4"
07 4113-I
RIDGE TRIM
R41 R41
1'-0"
M11
07 7100-A
MANUFACTURED COPING
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
06 1000-C02
PLYWOOD, FIRE
RETARDANT TREATED 3/4"
07 5419-A
(PVC) MEMBRANE ROOF
SYSTEM
LAP ROOF
MEMBRANE
OVER WRB
EMBED
SHEATHING
FABRIC IN WRB
COATING
RF11
M11 07 5419-A
(PVC) MEMBRANE ROOF
SYSTEM
06 1000-C02
PLYWOOD, FIRE
RETARDANT TREATED 3/4"
1'-0"
E
RF11
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
07 9200-B
BACKER ROD AND
SEALANT
08 4413-A
GLAZED ALUMINUM
CURTAIN WALL
SYSTEM, CLEAR
ANODIZED
05 5000-I
CONTINUOUS
VENTED Z-BAR AT
TOP AND BOTTOM.
PROVIDE BUG
SCREEN COVER
OVER VENT SLOTS.
PAINT EXTERIOR SIDE
TO MATCH METAL
COMPOSITE PANEL.
08 4413-F
ALUMINUM
COMPOSITE PANEL
05 1200-L
STEEL ANGLE L5 X 5 X
5/16 LLH
07 7100-A
MANUFACTURED
COPING
05 5000-I
CONTINUOUS
VENTED Z-BAR AT
TOP AND BOTTOM.
PROVIDE BUG
SCREEN COVER
OVER VENT SLOTS.
PAINT EXTERIOR SIDE
TO MATCH METAL
COMPOSITE PANEL.
1'-3" 2
D
RF41
M41
1'-0"
07 4213-A04
PREFINISHED METAL
J TRIM
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
06 1000-B01
WOOD NAILER, FIRE
RETARDANT TREATED
07 4113-G
RAKE / GABLE
FLASHING
M42
RF11
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:2
:3
P
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE541
ROOF DETAILS
SL
22-0227.001
CS, KK
ISSUED FOR
CONSTRUCTION
10/09/2024
05 1200-L STEEL ANGLE L5 X 5 X 5/16 LLH
05 5000-I CONTINUOUS VENTED Z-BAR AT TOP AND BOTTOM. PROVIDE BUG
SCREEN COVER OVER VENT SLOTS. PAINT EXTERIOR SIDE TO MATCH
METAL COMPOSITE PANEL.
06 1000-B01 WOOD NAILER, FIRE RETARDANT TREATED
06 1000-C02 PLYWOOD, FIRE RETARDANT TREATED 3/4"
07 4113-G RAKE / GABLE FLASHING
07 4113-H FLASHING
07 4113-I RIDGE TRIM
07 4213-A03 PREFINISHED METAL DRIP FLASHING
07 4213-A04 PREFINISHED METAL J TRIM
07 5400-D METAL TERMINATION BAR
07 5400-L 6" HIGH 20 GAUGE GALVANIZED STRAP
07 5419-A (PVC) MEMBRANE ROOF SYSTEM
07 6200-E PRE-MANUFACTURED METAL DOWNSPOUT, COLOR TO MATCH METAL
WALL PANEL
07 7100-A MANUFACTURED COPING
07 9200-B BACKER ROD AND SEALANT
08 4413-A GLAZED ALUMINUM CURTAIN WALL SYSTEM, CLEAR ANODIZED
08 4413-F ALUMINUM COMPOSITE PANEL
3" = 1'-0"C2 METAL PANEL WALL AT GUTTER
3" = 1'-0"A2 METAL PANEL WALL AT ROOF
3" = 1'-0"C1
METAL PANEL AT RIDGE
3" = 1'-0"D5
PARAPET DETAIL AT EIFS
3" = 1'-0"C5 ROOF WALL DETAIL AT EIFS
3" = 1'-0"A5 CURTAIN WALL PARAPET
3" = 1'-0"A1
METAL PANEL AT END WALL
1 1/2" = 1'-0"D1
SCREEN WALL ROOF DETAIL
2 11/22/2024 Addendum 006
ScottL PolyLine
ScottL Line
ScottL Arc
ScottL Text Box 1/8
ScottL Text Box
ScottL PolyLine
ScottL Polygon
ScottL Arrow
ScottL Text Box
EACH STUD, WEB SIDE
ScottL PolyLine
FECFEC
E
C
FEC
A. XX.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
M41
M41
07 4213-A02
PREFINISHED METAL
OUTSIDE CORNER TRIM
GRID
GRID
05 1200-B
STEEL COLUMN
1'-0"
P04A
DISPLAY CASE
09 6500-A
/2
AE582
D1
E
08 4413-A
GLAZED ALUMINUM
CURTAIN WALL SYSTEM,
CLEAR ANODIZED
M11
P04B
M11
05 1200-B
STEEL COLUMN
08 4413-A
GLAZED ALUMINUM
CURTAIN WALL SYSTEM,
CLEAR ANODIZED
08 4313-A
ALUMINUM-FRAMED
STOREFRONT SYSTEM,
CLEAR ANODIZED
07 9200-A
SEALANT
07 9200-A
SEALANT
1'-3"
06 1000-A01
WOOD SHIM, FIRE
RETARDANT TREATED
08 4413-J
PREMANUFACTURED
DOUBLE MULLION TRIM
PIECE
03A03B
09 6500-A
RESILIENT BASE; RA-1
09 6500-A
RESILIENT BASE; RA-1
09 3000
AE582
C1
A
B
3" 1'-0"
M11
M11
05 1200-B
STEEL COLUMN
AE582
C2
A
B
08 4313-A
ALUMINUM-FRAMED
STOREFRONT SYSTEM,
CLEAR ANODIZED
1'-0"
M11M11
04A
/2
/2
05 1200-B
STEEL COLUMN
P04B
M4109 6500-A
RESILIENT BASE; RA-1
07 2119-C
WINDOW AND DOOR
FILLER FOAM
09 6500-A
RESILIENT BASE; RA-1
10x6
6"
1'-0"
22° x1 xD
P06B
P13A
M41
08 4413-A
GLAZED ALUMINUM
CURTAIN WALL SYSTEM,
CLEAR ANODIZED
AE581
B3
1'-0"
1"
05 1200-B
STEEL COLUMN
P06B xA x3
M
P13A
P06A
8 1/2"
07 2119-C
WINDOW AND DOOR
FILLER FOAM
05 1200-B
STEEL COLUMN
08 4413-A
GLAZED ALUMINUM
CURTAIN WALL
SYSTEM, CLEAR
ANODIZED
08 4313-B
ALUMINUM-FRAMED
STOREFRONT
SYSTEM, MEDIUM
BRONZE
08 4413-K
PREMANUFACTURED
.60 ALUMINUM TRIM
PIECE TO MATCH
METAL PANEL
x3
P02BM11
09 6500-A
RESILIENT BASE; RA-1
09 6500-A
RESILIENT BASE; RA-1
1'-3" 2
P02E
09 6500-A
RESILIENT BASE; RA-1
09 6500-A
RESILIENT BASE; RA-1
09 6500-A
RESILIENT BASE; RA-1
09 3000
D
E
06 4100-B1606 4100-B16
06 4100-B16
09 6500-A
DISPLAY CASE
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:2
:4
P
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E
O F
F
IC
E B
U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE501
FLOOR PLAN
DETAILS
SL
22-0227.001
CS, KK
ISSUED FOR
CONSTRUCTION
10/09/2024
1 1/2" = 1'-0"A5 METAL WALL PANEL OUTSIDE CORNER
05 1200-B STEEL COLUMN
06 1000-A01 WOOD SHIM, FIRE RETARDANT TREATED
06 4100-B16 PLASTIC LAMINATE, PL-4. MITER FOLD LAMINATE OVER SUBSTRATE
PER MANUFACTURES INSTRUCTIONS
07 2119-C WINDOW AND DOOR FILLER FOAM
07 4213-A02 PREFINISHED METAL OUTSIDE CORNER TRIM
07 9200-A SEALANT
08 4313-A ALUMINUM-FRAMED STOREFRONT SYSTEM, CLEAR ANODIZED
08 4313-B ALUMINUM-FRAMED STOREFRONT SYSTEM, MEDIUM BRONZE
08 4413-A GLAZED ALUMINUM CURTAIN WALL SYSTEM, CLEAR ANODIZED
08 4413-J PREMANUFACTURED DOUBLE MULLION TRIM PIECE
08 4413-K PREMANUFACTURED .60 ALUMINUM TRIM PIECE TO MATCH METAL
PANEL
09 3000 TILING
09 6500-A RESILIENT BASE; RA-1
1 1/2" = 1'-0"C2
FLOOR PLAN DETAIL
1 1/2" = 1'-0"A1
PLAN DETAIL AT EIFS
1 1/2" = 1'-0"B5
PLAN DETAIL AT CW
1 1/2" = 1'-0"C4
PLAN DETAIL AT TILE
1 1/2" = 1'-0"A3
PLAN DETAIL AT EIFS
1 1/2" = 1'-0"A4
PLAN DETAIL AT EIFS
1 1/2" = 1'-0"E5
FLOOR PLAN DETAIL
1 1/2" = 1'-0"D5
FLOOR PLAN DETAIL
1 1/2" = 1'-0"C5
FLOOR PLAN DETAIL
1 1/2" = 1'-0"D4
FLOOR PLAN DETAIL
1 1/2" = 1'-0"D3
FLOOR PLAN DETAIL
1 1/2" = 1'-0"E3
FLOOR PLAN DETAIL
1 1/2" = 1'-0"E4
PLAN DETAIL AT TILE
1 1/2" = 1'-0"A2
FLOOR PLAN DETAIL
E
C
F E
C
FEC
F E
C
UP
A. ALL PLAN DIMENSIONS ARE TO FACE OF STUD OR CENTER OF COLUMN UNLESS
NOTED OTHERWISE.
B. REFER TO CIVIL FOR REFERENCE FINISH FLOOR ELEVATION.
C. REFER TO AF SHEETS FOR INTERIOR FINISH INFORMATION.
D. ALL WOOD BLOCKING, SHIMS AND PLYWOOD INSTALLED WITHIN WALL
ENCLOSURES TO BE FIRE RETARDANT.
E. REFER TO SHEET AE010 FOR PARTITION TYPES.
F. REFER TO SHEET AE121 FOR REFLECTED CEILING PLANS.
G. REFER TO BUILDING ELEVATIONS FOR LOCATIONS, TYPE, AND FINISH FOR ALL
EXTERIOR WALLS.
H. PROVIDE FIRE TREATED BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS.
I. LOCATE DOOR FRAMES / DOORS 4" FROM ADJACENT WALL.
J. PROVIDE BRACING AT DOOR FRAME LOCATIONS ON STRIKE SIDE AND PROVIDE
0.0312" THICK STEEL STUD AT DOOR STRIKE LOCATIONS.
K. PROVIDE VERTICAL CONTROL JOINTS IN GYPSUM BOARD PARTITIONS EVERY 30'-0"
MAXIMUM. ALIGN WITH DOOR FRAMES WHERE POSSIBLE.
L. COORDINATE LOCATION OF DATA AND ELECTRICAL ACCESS TO MODULAR
FURNITURE WITH OWNER.
M. ALL EXTERIOR GLAZING TO HAVE ROLLER SHADE SYSTEM, REFER TO OPENING
TYPES AE621, AE121A AND AE121B
N. PROVIDE TILE BACKING SUBSTRATE AT ALL LOCATIONS TO RECEIVE WALL TILE.
O. REFER TO FOOD SERVICE SHEETS FOR KITCHEN EQUIPMENT DRAWINGS.
P. REFER TO AE222 AND AE402 FOR LAB EQUIPMENT DRAWINGS.
Q. REFER TO ELECTRICAL DRAWINGS FOR IN FLOOR DEVICE LOCATIONS AT
CONFERENCE ROOMS.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
KEY PLAN
E5
A5 D5
C5
B5
AE201
E5
AE201
C4
AE462
FIRE RISER
M190
S / R
OFFICE
112G
VESTIBULE
H164
CONFERENCE
OFFICE168A
OFFICE168B
OFFICE168C
CONFERENCE168D
COPY / PRINT162
OFFICE168E
OFFICE168F
OFFICE168G
OFFICE168H
OFFICE168I
OFFICE168J
OFFICE168K
OFFICE168L
VESTIBULEH160
BREAKROOM
1'-0" 5'-2"
3'-6" 5'-8"
3'-6" 5'-6"
3'-6" 5'-7"
3'-6" 5'-5"
3'-6" 5'-6"
3'-6" 5'-5"
HALLWAY
H165
OPENOFFICE168
MM
NN
G
H
J
J
J
J
H
K
H
J
H
L
KK
LL
HH
E QQ PP
F
F
F
F
F
F
F
AE221
D3
HH
HH
HH
HH
HH
HH
HH
HH
HH
A
B
C
E
F
G
H
I
J
168K
168L
H164B H164A
M
H160A
H160B
M
112G
1'-0"
6'-8"
7'-9"
3'-0"
4'-3"
2'-9"
4'-3"
3'-0"
26'-8"
3'-0"
4'-3"
3'-0"
7'-9"
6'-7"
7'-9"
3'-0"
7'-9"
3'-0"
7'-9"
3'-0"
4'-3"
4'-7"
1'-0"
04B
04B
04B
03B
03B03B
04A
04A
04A
06B
04A
06B
13A
06B
06B
06B
06B
06B
06B
03B
03C
06B
06B
06B
06B
AE401
A5
06B
02B
02C
D5
AE301
B5
AE301
A5
AE301
B4
AE301
A2
AE302
AE501
E5
AE501
D5
3'-0"
AE501
C5
AE501
C5
AE501
D4
AE501
D3
AE501
E3
AE501
E4
AE501
B5
13A
13A
13A
13A
13A
13A
B2
AE202
A3
AE202
D5
AE201
D
HH
AE221
C1
3 5
5 7 8
L L
K xA xE xE xC xC x6 x1 x1 x2 x2 x3 x5
M M xB x4 xD xD.4
30'-0"
15'-0"
15'-0"
32'-0"
32'-0"
124'-0"
14'-9" 8'-0"
22'-9"
37'-2"
16'-3"
ABOVE
06B
ABOVE
ABOVE
ABOVE
ABOVE
ABOVEABOVE
ABOVE
ABOVE
ABOVE
ABOVE
06B
06B
06B
06B
06B
06B
06B
03B
06B
06B
AE223
B1
10 4400-C
FDC
M A
E163
10'-0"
10'-0"
10'-0"
8'-1"
9'-5"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
9'-3"
2 5.1
AE584
D3
10 7316-A03
09 8410-A
JJ
B5
AE209
E5
AE209
1'-3"
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:2
:3
P
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE101B
FLOOR PLAN -
AREA B
SL
22-0227.001
CS, KK
ISSUED FOR
CONSTRUCTION
10/09/2024
NORTH
1/8" = 1'-0"A5
FLOOR PLAN AREA B
NORTH
A
B
Existing Existing
09 8410-A SOUND-ABSORBING UNITS, SA-3; BID LOT 3. CENTER ON WALL AND
MOUNT AT 36" AFF, UNLESS NOTED OTHERWISE.
10 4400-C RAPID ENTRY BOX
10 7316-A03 PRE-MANUFACTURED ALUMINUM WALKWAY CANOPY 2, REFER TO
D3/AE462
A. DIMENSIONS ARE TO FINISHED FACE, UNLESS NOTED OTHERWISE.
B. SEE GI010 FOR TYPICAL ACCESSORY MOUNTING HEIGHTS.
C. PROVIDE BACKING FOR ATTACHING WALL MOUNTED ITEMS.
D. CENTER CASEWORK BETWEEN WALLS WITH NO MORE THAN 2” FILLER PANELS.
E. COORDINATE WALL ACCESS PANEL LOCATIONS AS TO NOT OVERLAP CHANGES IN
FINISHES.
F. ALIGN WALL TILE JOINTS WITH JOINTS IN FLOOR. AVOID USING LESS THAN HALF
THE WIDTH OF STANDARD TILES UNLESS OTHERWISE NOTED.
GENERAL SHEET NOTES
SHEET KEYNOTES
REFERENCE KEYNOTES
LEGEND
ACCENT WALL TILE, REFERENCE FINISH LEGEND
SOUND ABSORBING WALL UNITS, SA-3.
SOUND ABSORBING WALL UNITS, SA-4.
A2
AE361
A1
AE361
5'-0"
12 3600-E
06 4100-B16
09 3000-L
06 4100-B16
A2
AE361
A1
AE361
170"
48" 124" 06 4100-B16
12 3600-E
06 4100-B16
09 3000-L
09 3000-A
10 1400-D
EQ. EQ.
QUARTZ SEAM
LAMINATE SEAM
92"
A2
AE361
A1
AE361
24"
A5
AE361
09 6500-A
06 4100-B22
90 1/2"
06 4100-B01
12 3600-B01
12 3600-B02
C1
AE361
A3
AE361
D4
AE362
06 4100-B03
06 4100-B03
09 3000-B
09 6500-A
C5
AE361
36" 18"24"36"36"36"9"28"
48" 48"EQ. EQ.
06 4100-B01
6"
11 3013-H
11 3013-B
11 3013-C
MODIFY CASEWORK SHELVING
TO ACCOMMODATE RO SYSTEM
24"
09 7200-A
06 4100-L01
09 3000-B
06 4100-L02
D1
AE361
D2
AE361
D4
AE361
C4
AE361
18"24" 18" 24"
06 4100-B19
09 7200-A
06 4100-B01
C3
AE361
D3
AE361
06 4100-B01
12 3600-B01
06 4100-B01
06 4100-B01
4" 139"4"4" 70"119 1/2"
190 1/2"
12 3600-B01
11 3013-F 11 3013-A01
36"36"
12 3600-B01
06 4100-B22
09 6500-A
C1
AE361
1'-6"
TYP.
36"36"
C1
AE361
D5
AE361
06 4100-B22
09 6500-A
12 3600-B01
36"36"24"
12 3600-B01
C1
AE361
D5
AE361
34"36"
12 3600-B01
06 4100-B02
D4
AE362
C1
AE361
06 4100-B01
11 3013-A03
33"
06 4100-B04
09 3000-K
06 4100-B02
50"
06 4100-B02
09 6500-A
A4
AE361
MIN. OPENING
25"
A4
AE362
A2
AE362
A3
AE362
2 3/8" 37 3/4"
36"36"36"2" 21"
PULL
OUT
TRASH
21" 18" 18"36"
06 4100-B01
48"
12 3600-B01
C5
AE362
A5
AE362
B5
AE362
D5
AE362
166 1/2"
11 3013-E01
09 6500-A
166 1/2"
09 3000-K
12 3600-B01
10 1400-D
11 3013-E01
E Q
E Q
EQ.EQ.
A2
AE361
30"
A1
AE361
09 3000-L06 4100-B16
06 4100-M
(3) UNITS
96"
C3
AE361
32"
09 6500-B
109"
12 3600-B02
06 4100-B01
09 6500-A
12 3600-B01
3"
E5
AE362
D5
AE362
EQ.
09 8430-C
09 8430-C 09 6500-A
EQ.EQ.EQ.
C3
AE362
(3) UNITS
96" 32"
06 4100-M
06 4100-B22
12 3600-B01
09 6500-A
C2
AE361
24"
OPEN
36"
D5
AE361
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
08/08/2024
/4 /2
:0
:3
A
M
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
AE221
INTERIOR
ELEVATIONS
SL
22-0227.001
EA, KL
ISSUED FOR
CONSTRUCTION
10/09/2024
1/4" = 1'-0"A5
INTERIOR ELEVATION
1/4" = 1'-0"A4
INTERIOR ELEVATION
1/4" = 1'-0"A3
INTERIOR ELEVATION
1/4" = 1'-0"A1
INTERIOR ELEVATION
1/4" = 1'-0"C2
INTERIOR ELEVATION
1/4" = 1'-0"C3
INTERIOR ELEVATION
1/4" = 1'-0"D5
INTERIOR ELEVATION
1/4" = 1'-0"D4
INTERIOR ELEVATION
1/4" = 1'-0"D3
INTERIOR ELEVATION
1/4" = 1'-0"C5
INTERIOR ELEVATION
06 4100-B01 PLASTIC LAMINATE, PL-1
06 4100-B02 PLASTIC LAMINATE, PL-3
06 4100-B03 2" PLASTIC LAMINATE FRAME WITH GLASS INSERT, PL-1
06 4100-B04 2" PLASTIC LAMINATE FRAME WITH GLASS INSERT, PL-3
06 4100-B16 PLASTIC LAMINATE, PL-4. MITER FOLD LAMINATE OVER SUBSTRATE
PER MANUFACTURES INSTRUCTIONS
06 4100-B19 PLASTIC LAMINATE PANEL TO WRAP CORNERS TO BACK WALLS
06 4100-B22 PLASTIC LAMINATE, PL-2
06 4100-L01 UPHOLSTERED CUSHION, F-1
06 4100-L02 UPHOLSTERED CUSHION, F-2
06 4100-M DOUBLE SIDED CUSTOM DISPLAY CASE; SEE SPECIFICATIONS
09 3000-A WALL TILE, T-1; LARGE FORMAT TILE
09 3000-B WALL TILE, T-3
09 3000-K WALL TILE, T-11
09 3000-L WALL TILE BASE, TA-1
09 6500-A RESILIENT BASE; RA-1
09 6500-B RESILIENT BASE, RA-2
09 7200-A WALL COVERING, WC-1;
09 8430-C SOUND-ABSORBING UNITS, SA-3; BASE BID
10 1400-D DIMENSIONAL LETTER, SIGNAGE
11 3013-A01 REFRIGERATOR
11 3013-A03 REFRIGERATOR, UNDER-COUNTER
11 3013-B ICE MAKER
11 3013-C COFFEE BREWER
11 3013-E01 RANGE HOOD, VENTED TO EXTERIOR
11 3013-F MICROWAVE OVEN
11 3013-H DISHWASHER
12 3600-B01 SOLID SURFACE, SS-1
12 3600-B02 SOLID SURFACE, SS-2; 3" THICK EDGE W/ WATERFALL EDGE AND
TUBE STEEL FRAME.
12 3600-E QUARTZ COUNTERTOP, QZ-1
1/4" = 1'-0"B3
INTERIOR ELEVATION
1/4" = 1'-0"B2
INTERIOR ELEVATION
1/4" = 1'-0"B1
INTERIOR ELEVATION
04 APPLIANCE, NIC
05 PRINTER/COPIER, NIC
1/4" = 1'-0"A2
INTERIOR ELEVATION
1/4" = 1'-0"E2
INTERIOR ELEVATION
1/4" = 1'-0"C1
INTERIOR ELEVATION
1/4" = 1'-0"E3
INTERIOR ELEVATION
1/4" = 1'-0"B5
INTERIOR ELEVATION
DISPLAY CASE RENDERING
FOR REFERENCE ONLY
5.121 5
UP
FEC
5'-8" 5'-7" 11'-6"
3'-10"
'-0
1/FS501
7836 16
1/FS501
5436 84
1/FS501
7836 24
1/FS501
8'-6" HOLD
WALK-IN BOXES
G.C. TO MAINTAIN
HOLD TO DIM'S FOR
'-4
'-1
'-4
'-1
13'-4"
S/S FLASHING FROM
COVE BASE TO HOOD
S/S FLASHING FROM
COVE BASE TO HOOD
AND CEILING
'-6
1'-5"
G.7
K
J
H
L
DEMONSTRATION KITCHEN & SERVERY AREA PLAN
SCALE: 1/4" = 1'-0"
SK
SA
/2
/2
:1
:3
P M
CALIFORNIA ARIZONA NEW ENGLAND
TEL: (602) 443-0344
www.landmarkphx.com info@landmarkphx.com
22-0227.001
ISSUED FOR
CONSTRUCTION
10/09/2024
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
2 ADDENDUM 006 11/19/2024
FOODSERVICE
EQUIPMENT
SPECIAL
CONDITIONS PLAN
FS501
WALL BACKING FOR EQUIPMENT ABOVE 36"
(BY GENERAL CONTRACTOR)
SYMBOLS
S/S WALL FLASHING
(BY K.E.C.)
OVERALL WIDTH
OF BACKING (A)
ABOVE
FLOOR (C)
OVERALL HT.
OF BACKING (B)
HEIGHT
WALL BACKING LENGTHS ARE MINIMUM. ALWAYS EXTEND
TO NEXT STUD OVER IN EACH DIRECTION.
EQUIPMENT WALL BACKING DETAIL
* NOTE:
SEE BUILDING CONDITIONS PLAN.
16 GA. GALVANIZED
INSTALLED BY G.C.
STL. SUPPLIED &
ELEVATION
WALL BACKING
SEE NOTE
12 60
PLAN VIEW
(B
(A)
(C
PLAN INDICATES SIZE
G.7
K
J
H
L
5.121 5
UP
FEC
REFRIGERATION
LINES TO REMOTE
SYSTEM. VERIFY
LINE RUNS W/ SITE
CONDITIONS.
REMOTE SYSTEM
(VERIFY LOCATION) FIRE SUPPRESSION
& ELECTRICAL
CONTROL SYSTEM
SEE EXHAUST HOOD
DRAWINGS FOR
ADDITIONAL DETAILS
6'-6"
'-6
'-0
13'-0"
ME
ME
REMOTE FIRE
PULL STATION
P
REMOTE FIRE
PULL STATION
P
4'-4"
REMOTE SYSTEM
(VERIFY LOCATION)
REFRIGERATION
LINES TO REMOTE
SYSTEM. VERIFY
LINE RUNS W/ SITE
CONDITIONS.
DEMONSTRATION KITCHEN & SERVERY AREA PLAN
SCALE: 1/4" = 1'-0"
SK
SA
/2
/2
:1
:3
P M
CALIFORNIA ARIZONA NEW ENGLAND
TEL: (602) 443-0344
www.landmarkphx.com info@landmarkphx.com
22-0227.001
ISSUED FOR
CONSTRUCTION
10/09/2024
N M
S U
N M
D E
P T
O F
A G
R
IC
U L T
U R
E O
F F
IC
E
B U
IL
D
IN
G
A
G R
IC
U
L T
U R
E W
A Y
L A
S C
R U
C E
S N
E W
M E
X
IC
O
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
DATE
2 ADDENDUM 006 11/19/2024
FOODSERVICE
EQUIPMENT
MECHANICAL PLAN
FS401
SUPPLY
MECHANICAL ROUGH-IN SCHEDULE
ITEM QUA
HOOD SIZE
TAG
WL H
EXHAUST
C.F.M.
TOTAL HOOD
INCHES W.C.
AIR FLOW REQUIREMENTS
C.F.M.
EXHAUST
SIZE SIZE
SUPPLY WEIGHT
(LBS.)
HOOD
ME44 -0.797"44 1 60"144" 30" 117916"DIA2400 (EA)
EXHAUST HOOD REQUIREMENTS AND DUCT COLLAR
K.E.C. IS TO PROVIDE CLOSURE TRIM PANELS FROM
PROVIDE DISCONNECT ON ROOF FOR EXHAUST AND
DUCTWORK, EXHAUST AND MUA FANS TO BE PROVIDED
CONNECTED TO MICROSWITCHES IN THE FIRE SYSTEM.
HAVE SHUNT TRIP BREAKERS AT ELECTRICAL PANEL
ELECTRICAL EQUIPMENT UNDER EXHAUST HOOD MUST
AND INSTALLED BY THE GC'S MECHANICAL CONTRACTOR.
INCLUDED IN THE GC CONTRACT.
ALL FINAL DUCT WELDING AND CONNECTIONS TO BE
TOP OF HOOD TO CEILING & S/S WALL PANELS
SIZES SHALL BE COORDINATED WITH FINAL SHOP
DRAWINGS PRIOR TO FABRICATION.
5.
6.
1.
3.
2.
4.
M.U.A. FANS.
7. REFER TO ENGINEERING HOOD DATA SHEETS FOR COMPLETE CFM REQ'S
8. REFRIGERATION LINES ARE FOR SCHEMATIC PURPOSE ONLY.
9. K.E.C. & G.C. TO VERIFY EXACT LOCATION OF REFRIGERATION UNITS ON
THE ROOF WITH ARCHITECT PRIOR TO INSTALLATION.
MECHANICAL SYSTEM NOTES
FIRE PROTECTION
SYSTEM
TO MICRO SWITCH TO
"J" BOX & CONDUIT
"J" BOX & CONDUIT
TO MAIN ELECTRICAL
PANEL BY E.C. (ALL
SHUNT TRIP BREAKERS
SHUNT TRIP BREAKER
BY E.C.)
COMPANY TO TRIM
& SEAL AS REQ'D
PLANS PRIOR TO INSTALLATION
INSTALLING CONTRACTOR TO SUBMIT
A .F
.F
(V E
R
IF
Y
NOTE:
(V E
R
IF
Y
A .F
.F
INSTALLED BY FIRE
WALL OR FLUSH MOUNT
FIRE PROTECTION COMPANY
MANUAL PULL STATION BY
PROTECTION COMPANY
CONDUIT PROVIDED &
FIRE PROTECTION
CEILING
NOT TO SCALE
TYPICAL FIRE PROTECTION SYSTEM
NOT TO SCALE
1/2" TABS.
RECESSED REMOTE FIRE PULL DETAIL
4/0 BOXE WITH 1/2" TABS POSITIONED AS SHOWN
WITH TABS IN UPPER RIGHT AND LOWER LEFT OF BOX.
TO BE 12" ABOVE FINISHED DROP CEILING LINE WITHOUT
BOXES TO BE 60" ABOVE FINISHED FLOOR. 1/2" E.M.T.
CONDUIT AND 4/0 BOX WITH 1/2" TABS BY ELECTRICAL
REMOTE BOXES ARE MOUNTED SIDE-BY-SIDE THE DISTANCE
BETWEEN CENTERS SHALL NOT BE LESS THAN 7".
FOR EACH REMOTE PULL STATION. WHEN TWO (2)
BENDS OR OFFSETS. ONE (1) 4/0 BOX TO BE PROVIDED
CONTRACTOR.
FINISHED CEILING LINE.
1/2" TABS.
A .F
.F
ROOF LINE
CONTINUOUS
CANT STRIP
APPROX 12" OC
2"x6" WOOD (TYP.)
20 GA.
This is the start of the file's text. The full file is on GovTribe.