ADDENDUM _4.pdf

PDF 7 MB Posted

Attached to
26-003 LAW ENFORCEMENT RENOVATIONS - FLOYD COUNTY
Solicitation number
PE-65700-NONST-2026-000000076
Issued by
Fayette County, Georgia

About this file

Addendum #4 Summary – Floyd County Law Enforcement Center Renovation RFP #26-003

Addendum #4 is a pre-bid clarification document issued by Floyd County, Georgia Purchasing Department on March 5, 2026, for RFP #26-003 concerning the Law Enforcement Center Renovation project. The project involves comprehensive renovation of an existing three-story office building located at 5 Government Plaza, Rome, Georgia, totaling approximately 59,000 gross square feet with 18,013 square feet designated for renovation work. The scope includes updating office spaces with new gypsum walls, light fixtures, and floor finishes; creating a new courtroom to replace existing assembly space; adding public restrooms to the second and third-floor lobbies; constructing a holding cell adjacent to the Sheriff's Office; installing a new stretcher-complaint elevator in the entry lobby; updating mechanical, lighting, and electrical systems; and installing a new storefront entry door on the north side of the first floor. The building remains classified as Type IIB construction with Business and Assembly (A-3) occupancies under the 2018 International Building Code.

Addendum #4 provides critical clarifications and updates to the construction documents, including revised architectural plans, partition type schedules, finish specifications, door and signage schedules, and HVAC renovation plans for the second and third floors. Key clarifications specify that contractors are not required to use listed subcontractors; that pages 611–619 of Section 28-2000 VIDEO SURVEILLANCE from the Project Manual should be omitted; that holding cell benches must be DDS Detention Bed 7504L/R-M5 powder coated units; and that holding cells must be entirely tamper-proof and ligature-free. The addendum includes detailed acoustic transfer grille specifications, revised wall partition modifiers for height changes, updated finish schedules with specific material selections (including Patcraft luxury vinyl tile and Tarkett carpet tile options), and comprehensive HVAC renovation details requiring coordination with existing controls through Control Concepts Inc. The addendum confirms the building will remain operational during construction, with the 911 call center and essential data lines requiring continuous maintenance throughout the project duration.

View the file

Other files

File Type Posted
26_003 LAW ENFORCEMENT CENTER RENOVATIONS _ F.pdf PDF
ADDENDUM _3.pdf PDF
ADDENDUM _1.pdf PDF
Pre_Bid Sign_in Sheet _ Floyd County LEC Reno.pdf PDF
ADDENDUM _2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Twelve East Fourth Ave. Suite 106 ♦ ROME, GEORGIA 30161

PHONE (706) 291-5118

FLOYD COUNTY, GEORGIA

PURCHASING

TO: All Prospective Bidders: RFP #26-003 – “Law Enforcement Center Renovation”

FROM: Randy E. Self, Purchasing Director

SUBJECT: Clarification

DATE: March 5, 2026

RE: Addendum #2, Question #9

• The contractor is not required to use the subcontractors listed.

Please omit the last pages of section 28-2000 VIDEO SURVEILLANCE (pages 611-619, section 28 2000-10-18) from the Project Manual. See below for starting page (p.611) to be omitted.

RANDY E. SELF AMANDA JENKINS SHARON PASLEY

PURCHASING DIRECTOR PURCHASING AGENT PURCHASING AGENT

ADDENDUM #4

Twelve East Fourth Ave. Suite 106 ♦ ROME, GEORGIA 30161

PHONE (706) 291-5118

Additionally, please review the following updated information & drawings.

Thank you, Randy E. Self

Randy E. Self, Purchasing Director

Floyd County Board of Commissioners angelk Text Box

HOLDING CELL TOILET SPEC

Amanda Jenkins Highlight

Amanda Jenkins Highlight

Amanda Jenkins Highlight

Amanda Jenkins Highlight

Amanda Jenkins Highlight

Amanda Jenkins Highlight

01234 843 303 • sales@rcmproducts.co.uk • www.rcmproducts.co.uk

ACOUSTIC TRANSFER GRILLE - ATG

DESCRIPTION & FEATURES

Acoustic transfer grilles (ATG) are suitable for use in doors and partitions where ventilation and reduction in noise transfer or cross-talk from one area to another is required. The channel sections are internally lined with acoustic media.

ATG/F is complete with single mounting fl ange. ATG/BF complete with mounting fl ange plus loose telescopic rear fl ange to suit minimum 42mm to 110mm thickness door or partition.

Standard fi nish is RAL9010 or polyester powder coated to the customers colour requirement.

ATG ORDERING CODE

Series ATG

Core F - c/w Flange (one sided) BF - c/w Backing Flange (double sided)

Fixing F0 - No fi xings F1 - CSK Flange Fixing Holes

Finish

1 - (Mill Finish) 2 - RAL9006 (Silver/Grey) 3 - RAL9010 (White) 4 - RAL9005 (Black) 5 - RAL9003 (White) 6 - RAL9016 (White), 7 - Other RAL/BS Code (additional costs may apply)

8 - Chrome Finish - Powder Coated Example: ATG/BF/F1/3/Nominal Opening Size

Please refer to Performance Data for available standard sizes.

Other sizes/depths may be available upon request.

ATG PERFORMANCE DATA

Air Vol

(l/s) Size

(W x H) P.Drop

(Pa)

325 x 205

40 27 50 45

325 x 285

40 15 50 27 60 32 70 40 80 45

Air Vol (l/s)

Size (W x H)

P.Drop (Pa)

425 x 365

50 12 60 14 70 17 80 20 90 25

100 30 110 33 120 35 130 38 140 42 150 45

Air Vol (l/s)

Size (W x H)

P.Drop (Pa)

425 x 445

80 12 90 14

100 16 110 18 120 20 130 22 140 25 150 28 160 30 170 32 180 35 190 37 200 40 210 42 220 44 230 46

Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 Transmission Loss (dB) 2 3 3 5 7 11 13 18

Overall Nom A+57

Opening Size

P 1.

8.

R

A

TG

A co us ti c

Tr an sf er

G ri lle

A

TG

angelk

TRANSFER GRILL SPEC

DN

DN

DN

1 1.9 2 3 4 5 5.5 6 6.2 6.4 7 7.5 7.9 8 8.3 8.5 8.8 9

A

AV

AX

AZZ

AZ

B

BX

C

CX

D

E

AW

SHERIFF

OFFICE

HOLDING

254A

COPY/PRINT/DOCUMENT

ASSEMBLY

LOBBY

STAIR

MEN'S RR

UP

DOWN

DOWN

HOLDING

254B

COURTROOM

SEATING

259B

ALIGN

ALIGN

A210

OFFICE

PUBLIC DEF.

STORAGE

CORRIDOR

ATTORNEY

MTG.

EQUIPMENT

STORAGE

PROBATION

CORRIDOR

RECEPTION

DEP. CLERK

DEP. CLERK

DEP. CLERK

CLERK

PROBATION

PROBATION

ATTORNEY

MTG

WOMEN'S

RR

WOMEN

MEN

JANITOR

OFFICE

ATTORNEY

MTG

COMMUNICATION

ROOM

BREAK

ROOM

SUPPLY

EQUIPMENT

SUPERVISOR

CONFERENCE

DIRECTORDIRECTOR

SECRETARY

CLOSET

CLOSET

TOILET

TOILET

OFFICE

LOBBY

OFFICE

OFFICE OFFICE OFFICE

ELECT.

TELEPHONE

/DATA

235A

BREAKROOM

STOR.

SHERIFF

BULLPEN

246A

STORAGE OFFICE

CORRIDOR

ELEVATOR

STAIR

BREAK

ROOM

CORRIDOR

CONFERENCE

ROOM

OFFICE

OFFICE

OFFICE

A400

A400

254A 254B

256A

256B

251B

251A

259A

E204

E263 E264

E272

E271

E265

E257

E282 E281 E280 E279 E278 E277 E276 E275 E274

E273

STORAGE

E258

SHERIFF

SUPERVISOR

246B

A510

0S478

0M758A

0M758A

0S478

0S478S

/2

A210

1M1034NOT IN SCOPE

NOT IN SCOPE

0M758A

17'-7"2" 2"

7'-6" 0F414S A402

ALIGN

A L

IG

N

0S478S

EQ EQ

13'-2"

259C

1X414A

2X434A

5'-3"

15'-6 1/2" 0 S

F

A

F

A

F

A

1F478A

S

A

F

A

S

0S478

0C658S

0S478

0S478S

0S478S

0S478S

8'-0"

0M1914

259B E205

34H

42H

NOTE: 911 CALL CENTER TO REMAIN OPERATIONAL

FOR DURATION OF DEMOLITION & CONSTRUCTION

NOTE: MAINTAIN ESSENTIAL DATA LINES &

CONNECTIONS FOR DURATION OF DEMOLITION &

CONSTRUCTION (TO BE COORDINATED W/ OWNER)

6' - 6 1/2"

G400

0S478S

F

S

A401

11' - 3 1/2"

/2 "9' - 6"

" 3' - 5"

A570

9"

INSTALL

ACCESS

DOOR

C R

C R

CR C

R

C R

CR

C R

CR

C R

C R

A210

COURTROOM

259A

C R

C R

C R

C R

CR

11' - 3"

4' - 8"

E232

E233

E267

5' - 3 1/2"

/2

A101

CR

CR

E261

0F414S

0F414S

0F414S

0F414S

0F414S

A210

1. CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT

PARTITIONS, EXIT ENCLOSURES, AND FIRE WALLS SHALL BE

EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR

STENCILING ABOVE ANY DECORATIVE CEILING AND / OR IN CONCEALED

SPACE WITH LETTERS "A" MINIMUM OF TWO INCHES HIGH ON A

CONTRASTING BACKGROUND SPACED A MAXIMUM OF TWELVE FEET ON

CENTER WITH A MINIMUM OF ONE PER WALL OR BARRIER. THE HOURLY

FIRE RATING SHALL BE INCLUDED ON ALL RATED BARRIER OR WALLS.

SUGGESTED WORDING ( ) HOUR -- FIRE AND SMOKE BARRIER-PROTECT

ALL OPENINGS.

2. ALL VERTICAL PIPING EXPOSED IN ROOMS SHALL BE FURRED WITH

SAME MATERIAL AS ADJACENT WALLS. EXCEPTIONS ARE: MECHANICAL

ROOMS, ELECTRICAL ROOMS, TELEPHONE ROOMS.

3. METAL STUD PARTITIONS BEHIND ALL PLUMBING AND OTHER FIXTURES

SHALL BE BRACED TO STRUCTURE WHERE REQUIRED TO SUPPORT THE

EQUIPMENT PROVIDED.

4. DO NOT SCALE DRAWINGS. ALL DIMENSIONS AND CONDITIONS

INDICATED IN THESE DOCUMENTS MUST BE FIELD VERIFIED PRIOR TO

CONSTRUCTION. FOR DIMENSIONS NOT SHOWN OR IN QUESTION,

CONTRACTOR SHALL REQUEST CLARIFICATION FROM ARCHITECT

BEFORE PROCEEDING.

5. ANY DAMAGE INCURRED DURING CONSTRUCTION SHALL BE FULLY

REPLACED.

6. NEW GYPSUM BOARD CONSTRUCTION MEETING EXISTING GYPSUM

BOARD CONSTRUCTION IN THE SAME SHALL BE FLUSH WITH NO

VISIBLE JOINTS SHOWING.

7. PROVIDE COAT HOOK BEHIND DOORS IN ALL PRIVATE OFFICES, SINGLE

HOOK TYPE.

8. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY.

9. UNLESS OTHERWISE NOTED, INTERIOR PARTITION DIMENSIONS ARE

GIVEN FACE OF FINISH SURFACE TO FACE OF FINISH SURFACE.

10. ELECTRIC PANELS, ALARM BOXES, FIRE EQUIPMENT CABINETS AND

OTHER RECESSED BOXES GREATER THAN 16 SQUARE INCHES THAT

ARE LOCATED IN RATED WALLS SHALL BE BACKED BY GYPSUM

WALLBOARD LAYERS SUFFICIENT TO MAINTAIN THE DESIGNATED

RATING.

11. ALL EXISTING WORK, FURNISHINGS, EQUIPMENT OR MATERIAL TO

REMAIN THAT ARE DAMAGED BY CONTRACTOR'S OPERATION UNDER

THIS CONTRACT SHALL BE RECTIFIED OR REPAIRED AT NO

ADDITIONAL COST TO OWNER.

12. ALL PARTITIONS SHOWN AS 3 5/8" METAL STUDS U.N.O.. GENERAL

CONTRACTOR SHALL COORDINATE ACTUAL SIZE, GAUGE AND

SPACING OF METAL STUDS FOR ALL CONDITIONS.

13. CEILING ACCESS PANELS SHALL BE PROVIDED IN NON-ACCESSABLE

CEILING BELOW THE FOLLOWING MECHANICAL AND PLUMBING

DEVICES:

A. VALVES

B. FLOW MEASURING DEVICES

C. MIXING BOXES

D. POWER OPERATED DAMPERS

E. ACCESS PANELS IN DUCTWORK

F. VOLUME AND BALANCING DEVICES

G. WATER FLOW SWITCHES

H. SPRINKLER SYSTEM DRAINS AND TEST CONNECTIONS

I. PRESSURE SWITCHES

14. ALL FURNITURE BY OTHERS; NOT IN CONTRACT (N.I.C.) U.N.O.

15. ALL GYPSUM BOARD SHALL BE 5/8" THICK; PROVIDE CORNER

REINFORCEMENT AT ALL EXPOSED OUTSIDE CORNERS. EXCEPTION -

GYPSUM BOARD MAY BE ALTERNATE THICKNESS AT CONDITIONS

REQUIRING NEW CONSTRUCTION TO BE FLUSH WITH EXISTING.

16. PROVIDE SOLID WOOD BLOCKING INSIDE PARTITIONS FOR SECURING

WALL HUNG CABINETS/MILLWORK, SHELVING AND WALL HUNG

ACCESSORIES.

17. ALL DRYWALL FINISH WORK TO BE FINISH LEVEL 4, U.N.O.

18. ALL INTERIOR PARTITIONS TO BE TYPE 0S478, U.N.O.

19. ALL ANGLES ARE 90 DEGREES, U.N.O.

20. WHEN DIFFERENT PARTITION TYPES ARE LOCATED ADJACENT TO ONE

ANOTHER, THE FINISHED FACES OF THE PARTITIONS SHALL BE ALIGNED

AND FLUSH, U.N.O.

21. LOCATE EDGE OF DOOR OPENINGS 6" FROM INSIDE FACE OF ADJACENT

PARTITION, U.N.O.

22. CONTRACTOR TO PATCH ALL HOLES, SAND AND PAINT ALL WALLS

WITHIN SCOPE.

EXISTING CONSTRUCTION TO REMAIN

NEW PARTITION

NEW PARTITION (MASONRY)

A210

A402

A402

/2

10"

3' - 4"3' - 4"

5' - 1 1/2"

25' - 9"

4' - 8 1/2"

/2

/2

9' - 2" 5' - 7"8' - 7"

/2

/2

5' - 2 1/2"6

9' - 6" 1' - 4 1/2"

/2

/2

4' - 7 1/2"

6' - 11"

9' - 1 1/2"

A210

SCALE

DATE:

DRAWN BY:

CHECKED BY:

PROJECT #

THIS DRAWING IS AN INSTRUMENT OF

SERVICE AND SHALL REMAIN THE

PROPERTY OF THE ARCHITECT. NO

PART OF THIS DOCUMENT SHALL BE

REPRODUCED OR TRANSMITTED IN

ANY FORM, ELECTRONICALLY OR

MECHANICALLY, FOR ANY PURPOSE,

WITHOUT THE EXPRESS WRITTEN

PERMISSION OF THE ARCHITECT.

M A

R

IE

T T

A S

T R

E E

T

N W

U

N

IT

A

T L

A N

T A

G

E O

R G

IA

T

F w w w .s iz e m o re g ro u p

.c o m

S

IZ

E M

O R

E G

R O

U P

12/12/25

As indicated

12/15/2025 4:08:56 PMAutodesk Docs://24260FLOLEC_Floyd_County_Law_Enforcement_Center/24260SLOYLEC_Floyd_County_LEC.rvt

A101

OVERALL

PROPOSED

FLOOR PLANS –

2ND FLOOR

SMG

IDV

12/12/25

24260FLOLEC

F L

O Y

D C

O U

N T

Y L

E C

R E

N O

V A

T

IO

N

G O

V E

R N

M E

N T

P L

A Z

A R

O M

E

G A

100% CONSTRUCTION DOCUMENTS

1/8" = 1'-0"A101

1 PROPOSED FLOOR PLANS - 2ND FLOOR

N

0 40' 60' 80'20'

Graphic Scale: 1 inch = 20 feet

GENERAL NOTES

LEGEND

3/16" = 1'-0"A101

2 COURTROOM - ENLARGED PLAN

N o

D

E S

C R

IP

T

IO

N

D A

T E wproudfo Rectangle wproudfo Rectangle wproudfo Line wproudfo Line wproudfo PolyLine wproudfo Rectangle wproudfo Rectangle wproudfo Rectangle wproudfo Line wproudfo PolyLine wproudfo Line angelk

FOR REFERENCE: WALLS HIGHLIGHTED IN RED TO GO TO DECK (REFER TO DRAWING REVISIONS)

UP

1 1.9 2 3 4 5 5.5 6 6.2 6.4 7 7.5 7.9 8 8.3 8.5 8.8 9

A

AV

AX

AZZ

AZ

B

BX

C

CX

D

E

AW

MEN'S RR

STAIRS

UP

DOWN

DOWN

5"

FILE ROOM

SUPPLY

NOT IN SCOPE

NOT IN SCOPE

A211

FILE/VAULT

SUPPLY/STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

ELECTRICAL

373A

JANITOR

303A

WOMEN'S

RR

OFFICE

WORKSPACE

/ COUNTER

MEN

WOMEN

CHASE

JANITOR

WORKSPACE/COUNTER

OFFICE

OFFICE OFFICE OFFICE OFFICE

OFFICE

CONFERENCE

OFFICE

OFFICE

CONFERENCE OFFICE

A2112

A211

A211

WORKSPACE

A211

A210

E304

367A

E306

353 354 355 356

373A

E373C

373B

E360 E361 E362

CORRIDOR

A510

A21110

3' - 6" 24' - 9"

4'

6" 1'

1'

"4'

7"

0S478

0F414

0F414

F

0F414

0S478

A211

A211 11

1M758A 1M1034

1M758A

A211

A211 8

13' - 5 1/2"

2' - 3"

14' - 3"

14' - 9"

A400

S

S

/2

.0

A L

IG

N

ALIGN

2' - 4"

A500

3A500

INFILL WALL OPENINGS

9'-3"

5'-0"

2'-8 1/2"

0S478

0S478

0S478

S

0S478S

S

S

S

S

0S478S

0S478S

26' - 9"

/2

S

A500

MIN.

1' - 6"

OFFICE

STORAGE

3' - 0"

ALIGN

ALIGN

367B

E375

E376

E377

ALIGN

A500

F

A500

A500

A500

A211

0M758SW 0M758SW

(1'-6'' MIN.)

1' - 8"

34H

42H

5' - 4 1/2"

W01

W02

W03

W02

W04

0S478S

0C658S

S

S

0S478S

0C658S

NOTE: MAINTAIN ESSENTIAL DATA LINES &

CONNECTIONS FOR DURATION OF DEMOLITION &

CONSTRUCTION (TO BE COORDINATED W/ OWNER)

/2

/2

S

C R

CR

CR

C R

CR

C R

C R

C R

ELEC.

TELEPHONE

DATA

329A

BREAKROOM

OFFICESTORAGE

STORAGE

STORAGE OFFICE BREAKROOM STORAGE

WOMEN'S

LOCKERS EVIDENCE

STAIRS

4' - 6" 4' - 4 1/2"

W02

3' - 1"

/2

/2

1' - 1"

/2

C R

CR

E326

301301

FEC

1. CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT

PARTITIONS, EXIT ENCLOSURES, AND FIRE WALLS SHALL BE

EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR

STENCILING ABOVE ANY DECORATIVE CEILING AND / OR IN CONCEALED

SPACE WITH LETTERS "A" MINIMUM OF TWO INCHES HIGH ON A

CONTRASTING BACKGROUND SPACED A MAXIMUM OF TWELVE FEET ON

CENTER WITH A MINIMUM OF ONE PER WALL OR BARRIER. THE HOURLY

FIRE RATING SHALL BE INCLUDED ON ALL RATED BARRIER OR WALLS.

SUGGESTED WORDING ( ) HOUR -- FIRE AND SMOKE BARRIER-PROTECT

ALL OPENINGS.

2. ALL VERTICAL PIPING EXPOSED IN ROOMS SHALL BE FURRED WITH

SAME MATERIAL AS ADJACENT WALLS. EXCEPTIONS ARE: MECHANICAL

ROOMS, ELECTRICAL ROOMS, TELEPHONE ROOMS.

3. METAL STUD PARTITIONS BEHIND ALL PLUMBING AND OTHER FIXTURES

SHALL BE BRACED TO STRUCTURE WHERE REQUIRED TO SUPPORT THE

EQUIPMENT PROVIDED.

4. DO NOT SCALE DRAWINGS. ALL DIMENSIONS AND CONDITIONS

INDICATED IN THESE DOCUMENTS MUST BE FIELD VERIFIED PRIOR TO

CONSTRUCTION. FOR DIMENSIONS NOT SHOWN OR IN QUESTION,

6. NEW GYPSUM BOARD CONSTRUCTION MEETING EXISTING GYPSUM

BOARD CONSTRUCTION IN THE SAME SHALL BE FLUSH WITH NO

VISIBLE JOINTS SHOWING.

7. PROVIDE COAT HOOK BEHIND DOORS IN ALL PRIVATE OFFICES, SINGLE

HOOK TYPE.

8. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY.

9. UNLESS OTHERWISE NOTED, INTERIOR PARTITION DIMENSIONS ARE

GIVEN FACE OF FINISH SURFACE TO FACE OF FINISH SURFACE.

10. ELECTRIC PANELS, ALARM BOXES, FIRE EQUIPMENT CABINETS AND

OTHER RECESSED BOXES GREATER THAN 16 SQUARE INCHES THAT

ARE LOCATED IN RATED WALLS SHALL BE BACKED BY GYPSUM

WALLBOARD LAYERS SUFFICIENT TO MAINTAIN THE DESIGNATED

RATING.

11. ALL EXISTING WORK, FURNISHINGS, EQUIPMENT OR MATERIAL TO

REMAIN THAT ARE DAMAGED BY CONTRACTOR'S OPERATION UNDER

SPACING OF METAL STUDS FOR ALL CONDITIONS.

13. CEILING ACCESS PANELS SHALL BE PROVIDED IN NON-ACCESSABLE

C. MIXING BOXES

D. POWER OPERATED DAMPERS

E. ACCESS PANELS IN DUCTWORK

F. VOLUME AND BALANCING DEVICES

G. WATER FLOW SWITCHES

H. SPRINKLER SYSTEM DRAINS AND TEST CONNECTIONS

I. PRESSURE SWITCHES

14. ALL FURNITURE BY OTHERS; NOT IN CONTRACT (N.I.C.) U.N.O.

15. ALL GYPSUM BOARD SHALL BE 5/8" THICK; PROVIDE CORNER

REINFORCEMENT AT ALL EXPOSED OUTSIDE CORNERS. EXCEPTION -

GYPSUM BOARD MAY BE ALTERNATE THICKNESS AT CONDITIONS

REQUIRING NEW CONSTRUCTION TO BE FLUSH WITH EXISTING.

16. PROVIDE SOLID WOOD BLOCKING INSIDE PARTITIONS FOR SECURING

WALL HUNG CABINETS/MILLWORK, SHELVING AND WALL HUNG

ACCESSORIES.

17. ALL DRYWALL FINISH WORK TO BE FINISH LEVEL 4, U.N.O.

18. ALL INTERIOR PARTITIONS TO BE TYPE 0S478, U.N.O.

19. ALL ANGLES ARE 90 DEGREES, U.N.O.

20. WHEN DIFFERENT PARTITION TYPES ARE LOCATED ADJACENT TO ONE

ANOTHER, THE FINISHED FACES OF THE PARTITIONS SHALL BE ALIGNED

AND FLUSH, U.N.O.

21. LOCATE EDGE OF DOOR OPENINGS 6" FROM INSIDE FACE OF ADJACENT

PARTITION, U.N.O.

22. CONTRACTOR TO PATCH ALL HOLES, SAND AND PAINT ALL WALLS

WITHIN SCOPE.

EXISTING CONSTRUCTION TO REMAIN

NEW PARTITION

NEW PARTITION (MASONRY)

SCALE

DATE:

DRAWN BY:

CHECKED BY:

PROJECT #

THIS DRAWING IS AN INSTRUMENT OF

SERVICE AND SHALL REMAIN THE

PROPERTY OF THE ARCHITECT. NO

PART OF THIS DOCUMENT SHALL BE

REPRODUCED OR TRANSMITTED IN

ANY FORM, ELECTRONICALLY OR

MECHANICALLY, FOR ANY PURPOSE,

WITHOUT THE EXPRESS WRITTEN

PERMISSION OF THE ARCHITECT.

M A

R

IE

T T

A S

T R

E E

T

N W

U

N

IT

A

T L

A N

T A

G

E O

R G

IA

T

F w w w .s iz e m o re g ro u p

.c o m

S

IZ

E M

O R

E G

R O

U P

12/12/25

1/8" = 1'-0"

12/15/2025 4:08:58 PMAutodesk Docs://24260FLOLEC_Floyd_County_Law_Enforcement_Center/24260SLOYLEC_Floyd_County_LEC.rvt

A102

OVERALL

PROPOSED

FLOOR PLANS –

3RD FLOOR

SMG

IDV

12/12/25

24260FLOLEC

F L

O Y

D C

O U

N T

Y L

E C

R E

N O

V A

T

IO

N

G O

V E

R N

M E

N T

P L

A Z

A R

O M

E

G A

100% CONSTRUCTION DOCUMENTS

1/8" = 1'-0"A102

1 PROPOSED FLOOR PLANS - 3RD FLOOR

N

0 40' 60' 80'20'

Graphic Scale: 1 inch = 20 feet

GENERAL NOTES

CR

CR

LEGEND

N o

D

E S

C R

IP

T

IO

N

D A

T E wproudfo PolyLine wproudfo PolyLine angelk

FOR REFERENCE: WALLS HIGHLIGHTED IN RED TO GO TO DECK (REFER TO DRAWING REVISIONS)

Revision Narrative

SIZEMORE GROUP

5 GOVERNMENT PLAZA 342 Marietta St. NW, Unit 3 ROME, GA 30161 Atlanta, GA 30313

SHEET NUMBER SHEET NAME DESCRIPTION

G000 COVER SHEET ADDED ADD ALTERNATE: "ACOUSTICAL WALL PANELS IN COURTROOM" PREVIOUSLY LISTED ON FINISH SHEETS G400 PARTITION TYPES UPDATED WALL PARTITION MODIFIERS AND SCHEDULES FOR WALL HEIGHT CHANGES

A100 OVERALL PROPOSED FLOOR PLANS 1ST FLOOR ADDED GENERAL NOTE FOR CLARIFICATION

A101 OVERALL PROPOSED FLOOR PLANS 2ND FLOOR UPDATED WALL TAGS TO LABEL WALLS THAT ARE TO GO TO UNDERSIDE OF DECK

ADDED ELEVATION TAG FOR 267 RECEPTION DESK (ELEVATION PREVIOUSLY SHOWN ON ELEVATION SHEET)

ADDED GENERAL NOTES FOR CLARIFICATION

A102 OVERALL PROPOSED FLOOR PLANS 3RD FLOOR UPDATED WALL TAGS TO LABEL WALLS THAT ARE TO GO TO UNDERSIDE OF DECK

ADDED SERVICE WINDOW ELEVATION TAG AT OFFICE 368 FOR CLARIFICATION

ADDED GENERAL NOTES FOR CLARIFICATION

A171 FINISH PLAN - 1ST FLOOR UPDATED LVT-1 IN FINISH SCHEDULE TO PREFERRED SUBSTITUTION

UPDATED FINISH NOTES FOR CLARIFICATION

A172 FINISH PLAN - 2ND FLOOR UPDATED FINISH NOTES FOR CLARIFICATION

A173 FINISH PLAN - 3RD FLOOR UPDATED FINISH NOTES FOR CLARIFICATION

A210 INTERIOR ELEVATIONS CORRECTED RM NUMBER IN ELEVATION NAME

ADDED SERVICE WINDOW ELEVATION AT OFFICE 368 FOR CLARIFICATION

A211 INTERIOR ELEVATIONS ADDED PL REGION AND WOOD TRIM LOCATIONS IN THE TRANSACTION WINDOW ELEVATIONS

A400 ENLARGED RESTROOM PLANS UPDATED FIXTURE SCHEDULE TO INCLUDE CELL FIXTURES

REMOVED TOILET ROOM GENERAL NOTE

A600 DOOR SCHEDULE AND DETAILS ADDED COURTROOM GATE ELEVATION FOR CLARIFICATION

A900 SIGNAGE TYPES AND ELEVATIONS UPDATED SIGNAGE SCHEDULE TO INCLUDE "SIGNAGE TEXT" COLUMN

A904 SIGNAGE PLAN - 3RD FLOOR UPDATED AND CLARIFIED SIGNAGE LOCATIONS

M201 HVAC RENOVATION PLAN - SECOND FLOOR UPDATED KEYNOTES FOR CLARIFICATION

UPDATED GENERAL NOTES FOR CLARIFICATION

M301 HVAC RENOVATION PLAN - THRID FLOOR UPDATED GENERAL NOTES FOR CLARIFICATION

24260FLOLEC - FLOYD COUNTY LEC RENOVATION

NFPA 101, 2018 EDITION

4.6.10 CONSTRUCTION, REPAIR, AND IMPROVEMENT OPERATIONS

BUILDINGS, OR PORTIONS OF BUILDINGS, SHALL BE PERMITTED TO BE OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS, OR ADDITIONS ONLY WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED FOR THE PORTION OCCUPIED OR WHERE ALTERNATIVE LIFE SAFETY MEASURES ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION ARE IN

PLACE.

FIRE PROTECTION:

PLANS FOR FIRE PROTECTION SPRINKLER PIPING INCLUDING COMPLETE SEISMIC SUPPORT DETAILS SHALL BE REVIEWED AND APPROVED BY THE COA FIRE MARSHAL'S OFFICE PRIOR TO INSTALLATION FOR COMPLIANCE

WITH ASCE/ SEI 7-10 SECTIONS 13.3.1, 13.3.2, ABD NFPA 13.

GENERAL PROJECT NOTES:

A. ALL INTERIOR FINISH CLASSIFICATIONS SHALL COMPLY WITH 2018 NFPA 101: 38.3.3.1, “INTERIOR FINISH

SHALL BE IN ACCORDANCE WITH SECTION 10.2.” .

B. GENERAL: SAFETY GLAZING SHALL BE PERMANENTLY IDENTIFIED PER 2018 IBC: 2406.3.

C. ALL DEMOLITION WORK SHALL COMPLY WITH THE REQUIREMENTS OF 2019 NFPA 241, STANDARD FOR SAFEGUARDING ANY REQUIREMENTS FOR AIR FILTERING OR SYSTEMS THAT MUST REMAIN IN OPERATION

DURING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS.

D. GENERAL: ALL FIRE AND/OR SMOKE BARRIERS OR WALLS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING ABOVE A DECORATIVE CEILING AND / OR IN CONCEALED SPACES WITH LETTERS A MINIMUM OF TWO (2) INCHES HIGH ON A CONTRASTING BACKGROUND SPACED A MAXIMUM OF

TWELVE (12) FEET ON CENTER WITH A MINIMUM OF ONE PER WALL OR BARRIER IN

1. CONTRACTORS SHALL VISIT THE SITE PRIOR TO BIDDING THE PROJECT TO VERIFY EXISTING FIELD

CONDITIONS. BID SUBMISSION SHALL AFFIRM CONTRACTOR MADE ALLOWANCES FOR SAID

CONDITIONS AND RELATED PROJECT COSTS.

2. WORK IS TO BE PERFORMED IN AN EXISTING FACILITY. CONTRACTOR SHALL COORDINATE ALL WORK, INCLUDING INTERRUPTION OF UTILITIES AND BUILDING SERVICE WITH THE OWNER OR BUILDING

MANAGEMENT. PHASING OF WORK IS TO BE PERFORMED AND COORDINATED TO ACCOMMODATE

EXISTING FACILITY OPERATIONS.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR COST AND WORK ASSOCIATED WITH CUTTING AND

PATCHING OF EXISTING FACILITY AS REQUIRED TO COMPLETE THIS PROJECT. AFFECTED AREAS

SHALL BE RESTORED OR REPAIRED TO LEAVE IN "LIKE-NEW" CONDITION AND MATCHING

SURROUNDING SURFACES.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR COSTS ASSOCIATED WITH BUILDING UTILITY EQUIPMENT

SHUTDOWNS AND FIRE WATCHES.

5. SHOULD STOPPAGE OF WORK OCCUR THE CONTRACTOR SHALL LEAVE THE FACILITY IN A WEATHER TIGHT CONDITION OCCUPIED FACILITIES SYSTEMS SHALL BE LEFT IN AN OPERATIONAL STATE TO

ALLOW CONTINUED NORMAL FACILITIES OPERATIONS.

6. ALL RENOVATION WORK IS TO BE PERFORMED IN COMPLIANCE WITH IFC 2012, SECTION 3304.2 WASTE DISPOSAL. COMBUSTIBLE DEBRIS AND WASTE MATERIAL SHALL BE REMOVED FROM THE BUILDING AT

THE END OF EACH SHIFT OF WORK.

7. ALL DEMOLITION WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 241, 2013 EDITION, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS.

8. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF THE ELEVATORS THROUGHOUT

CONSTRUCTION.

9. NO MUSIC OR LOUD CONSTRUCTION DURING DAY HOURS, PROVIDE ACOUSTIC INSULATION AT

CONSTRUCTION BARRIER.

SCOPE OF WORK: RENOVATION OF AN EXISTING OFFICE BUILDING

WILL INVOLVE UPDATING OFFICE SPACES WITH NEW GYPSUM

WALLS, LIGHT FIXTURES, AND FLOOR FINISHES. A NEW

COURTROOM WILL REPLACE THE EXISITNG ASSEMBLY SPACE.

ADDITIONAL PUBLIC RESTROOMS WILL BE ADDED TO THE 2ND AND

3RD FLOOR LOBBIES. A HOLDING CELL WILL BE LOCATED

ADJACENT TO THE SHERIFF'S OFFICE. A NEW STRETCHER-

COMPLAINT ELEVATOR WILL BE ADDED TO THE EXISITNIG ENTRY

LOBBY. VARIOUS FINISH UPDATES WILL BE MADE ON THE 2ND AND

3RD FLOORS. A NEW STOREFRONT ENRTY DOOR WILL BE

INSTALLED ON THE NORTH SIDE OF THE FIRST FLOOR. MECHANICAL

UNITS, NEW LIGHTING AND ELECTRICAL UPDATES WILL ALSO BE

INCLUDED IN THE RENOVATION. THERE WILL BE NO CHANGE TO

THE BUILDING'S USE GROUP (BUSINESS).

PERMITTING AGENCY

ROME, GA

ROME-FLOYD COUNTY BUILDING INSPECTION DEPARTMENT

607 BROAD ST.

ROME, GA 30162

TEL: 706-236-4480

CONSTRUCTION TYPE (PER CHAPTER 6 - 2018 IBC)

BLDG.: TYPE IIB SPRINKLERED

OCCUPANCY TYPE

BLDG.: B, A-3

AREA

FIRST FLOOR 19,220 GSF

SECOND FLOOR 19,890 GSF

THIRD FLOOR 19,890 GSF

TOTAL 59,000 GSF

AREA OF RENOVATION

FIRST FLOOR 1,547 GSF

SECOND FLOOR 7,843 GSF

THIRD FLOOR 8,623 GSF

TOTAL 18,013 GSF

BUILDING HEIGHT

BLDG.: 47'-6 1/4"

OWNER

FLOYD COUNTY

12 EAST 4TH AVENUE

ROME, GA 30161

RYAN DAVIS

FACILITIES MANAGER

ARCHITECT

SIZEMORE GROUP, LLC

342 MARIETTA STREET, NW | UNIT 3 |

ATLANTA, GA 30313

TEL: 404-605-0690

FAX: 404-605-0890

KATHRYN SCOTT

PRINCIPAL IN CHARGE, SIZEMORE GROUP

ANGEL KAUFFMANN

PROJECT MANAGER

STRUCTURAL

PALMER ENGINEERING COMPANY

3585 HABERSHAM, BUILDING N

TUCKER, GA 30084

TEL: 770-908-9908

BRIAN NANNIS

VICE PRESIDENT

MECHANICAL, PLUMBING, AND FIRE PROTECTION

DRINKARD ENGINEERING GROUP

300 JOHN DAVENPORT DR.

ROME, GA 30162

TEL: 888-687-3589

JEFF DRINKARD

PROJECT ENGINEER

ELECTRICAL

LUNDY ENGINEERING GROUP

229 LAND ROAD

WALESKA, GA 30183

TEL: 678-634-6941

ANDREW LUNDY

PROJECT ENGINEER

LOW VOLTAGE

NEWCOMB & BOYD

303 PEACHTREE CENTER, NE | SUITE 525 |

ATLANTA, GA 30303

TEL: 404-730-8400

MILES HOLCOMBE

SECURITY CONSULTANT

GLADYS MARROQUIN

AV CONSULTANT

NICK SCHNEIDER

COMMUNICATIONS CONSULTANT

NOT TO SCALE

SCALE

DATE:

DRAWN BY:

CHECKED BY:

PROJECT #

THIS DRAWING IS AN INSTRUMENT OF

SERVICE AND SHALL REMAIN THE

PROPERTY OF THE ARCHITECT. NO

PART OF THIS DOCUMENT SHALL BE

REPRODUCED OR TRANSMITTED IN

ANY FORM, ELECTRONICALLY OR

MECHANICALLY, FOR ANY PURPOSE,

WITHOUT THE EXPRESS WRITTEN

PERMISSION OF THE ARCHITECT.

M

A R

IE

T

T A

S T

R E

E T

N

W U

N

IT

A

T L A

N T

A

G E

O R

G

IA

T

F w w w .s iz e m o re g ro u p

.c o m

S

IZ

E

M O

R E

G R

O U

P

12/12/25

As indicated

3/5/2026 11:41:26 AMAutodesk Docs://24260FLOLEC_Floyd_County_Law_Enforcement_Center/24260SLOYLEC_Floyd_County_LEC.rvt

G000

COVER SHEET

ANGEL

WYATT

12/12/25

24260FLOLEC

F L O

Y D

C O

U N

T Y

L E

C R

E N

O V

A T

IO

N

G

O V

E R

N M

E N

T P

L A

Z A

R O

M E

G

A

100% CONSTRUCTION DOCUMENTS

PROJECT DIRECTORYVICINITY MAP

BUILDING CODES & CONSTRUCTION INFORMATIONBUILDING INFORMATION

N

FLOYD COUNTY

LAW ENFORCEMENT CENTER RENOVATION

5 GOVERNMENT PLAZA

ROME, GA 30161

ADD OR DEDUCT ALTERNATES

OWNER PROVIDED ITEMS AND COMPONENTS

GENERAL NOTES

SHEET # SHEET NAME

ISSUE

DATE

CURRENT

REV.

GENERAL

G000 COVER SHEET 12/12/25 3

G002 ABBREVIATIONS AND LEGENDS 12/12/25

G100 SITE ACCESS PLAN 12/12/25

G200 CODE REVIEW 12/12/25

G300 LIFE SAFETY PLAN - LEVEL 01 12/12/25

G301 LIFE SAFETY PLAN - LEVEL 02 12/12/25

G302 LIFE SAFETY PLAN - LEVEL 03 12/12/25

G400 PARTITION TYPES 12/12/25 3

G500 ACCESS PLAN - LEVEL 01 12/12/25

G501 ACCESS PLAN - LEVEL 02 12/12/25

G900 UL Details 12/12/25

G901 UL Details 12/12/25

G902 UL Details 12/12/25

ARCHITECTURE

AD000 DEMOLITION PLAN - 1ST FLOOR 12/12/25

AD001 DEMOLITION PLAN - 2ND FLOOR 12/12/25

AD002 DEMOLITION PLAN - 3RD FLOOR 12/12/25

AD150 DEMOLITION RCP - 1ST FLOOR 12/12/25

AD151 DEMOLITION RCP - 2ND FLOOR 12/12/25

AD152 DEMOLITION RCP - 3RD FLOOR 12/12/25

A100 OVERALL PROPOSED FLOOR PLANS – 1ST FLOOR 12/12/25 3

A101 OVERALL PROPOSED FLOOR PLANS – 2ND FLOOR 12/12/25 3

A102 OVERALL PROPOSED FLOOR PLANS – 3RD FLOOR 12/12/25 3

A153 OVERALL PROPOSED RCP – 1ST FLOOR 12/12/25

A154 OVERALL PROPOSED RCP – 2ND FLOOR 12/12/25

A155 OVERALL PROPOSED RCP – 3RD FLOOR 12/12/25

A171 FINISH PLAN - 1ST FLOOR 12/12/25 3

A172 FINISH PLAN - 2ND FLOOR 12/12/25 3

A173 FINISH PLAN - 3RD FLOOR 12/12/25 3

A190 FURNITURE PLAN - 2ND FLOOR 12/12/25

A191 FURNITURE PLAN - 3RD FLOOR 12/12/25

A200 EXTERIOR ELEVATIONS 12/12/25

A210 INTERIOR ELEVATIONS 12/12/25 3

A211 INTERIOR ELEVATIONS 12/12/25 3

A400 ENLARGED RESTROOM PLANS 12/12/25 3

A401 ENLARGED HOLDING CELL PLANS 12/12/25 3

A402 ENLARGED JUDGES BENCH PLAN 12/12/25

A500 DETAIL VIEW 12/12/25

A510 VERTICAL CIRCULATION 12/12/25

A570 MILLWORK DETAILS 12/12/25

A600 DOOR SCHEDULE AND DETAILS 12/12/25 3

A601 WINDOW SCHEDULE AND DETAILS 12/12/25

A900 SIGNAGE TYPES AND ELEVATIONS 12/12/25 3

A901 SIGNAGE TYPES AND ELEVATIONS 12/12/25

A902 SIGNAGE PLAN - 1ST FLOOR 12/12/25

A903 SIGNAGE PLAN - 2ND FLOOR 12/12/25

A904 SIGNAGE PLAN - 3RD FLOOR 12/12/25 3

STRUCTURAL

S001 GENERAL NOTES AND TYPICAL DETAILS 12/12/25

S002 STATEMENT OF SPECIAL INSPECTIONS 12/12/25

S101 FOUNDATION PLAN 12/12/25

S102 SECOND FLOOR FRAMING PLAN 12/12/25

S103 THIRD FLOOR FRAMING PLAN 12/12/25

S104 ROOF FRAMING PLAN 12/12/25

S301 SECTIONS & DETAILS 12/12/25

S401 SECTIONS & DETAILS 12/12/25

MECHANICAL

M001 HVAC NOTES, LEGENDS & SCHEDULES 12/12/25

M002 HVAC NOTES, LEGENDS & SCHEDULES 12/12/25

M101 HVAC RENOVATION PLAN - FIRST FLOOR 12/12/25

M201 HVAC RENOVATION PLAN - SECOND FLOOR 12/12/25

M301 HVAC RENOVATION PLAN - THIRD FLOOR 12/12/25

M401 HVAC SPECIFICATIONS 12/12/25

M402 HVAC SPECIFICATIONS 12/12/25

ELECTRICAL

E001 ELECTRICAL NOTES, LEGEND, AND SPECIFICATIONS 12/12/25

E002 ELECTRICALDETAILS & SCHEDULES 12/12/25

E003 ELECTRICAL SCHEDULES 12/12/25

E004 ELECTRICAL SCHEDULES 12/12/25

ED101 ELECTRICAL CEILING DEMOLITION PLAN 1ST FLOOR 12/12/25

ED102 ELECTRICAL CEILING DEMOLITION PLAN 2ND FLOOR 12/12/25

ED103 ELECTRICAL CEILING DEMOLITION PLAN 3RD FLOOR 12/12/25

E101 ELECTRICAL CEILING PLAN 1ST FLOOR 12/12/25

E102 ELECTRICAL CEILING PLAN 2ND FLOOR 12/12/25

E103 ELECTRICAL CEILING PLAN 3RD FLOOR 12/12/25

ED201 ELECTRICAL FLOOR DEMOLITION PLAN 1ST FLOOR 12/12/25

ED202 ELECTRICAL FLOOR DEMOLITION PLAN 2ND FLOOR 12/12/25

ED203 ELECTRICAL FLOOR DEMOLITION PLAN 3RD FLOOR 12/12/25

E201 ELECTRICAL FLOOR PLAN 1ST FLOOR 12/12/25

E202 ELECTRICAL FLOOR PLAN 2ND FLOOR 12/12/25

E203 ELECTRICAL FLOOR PLAN 3RD FLOOR 12/12/25

PROJECT SCOPE OF WORK

ADD ALTERNATES:

1. REPLACE ALL STOREFRONT WINDOWS AT ENTRANCE TOWER AND INCLUDE 3M FILM.

2. INCLUDE 3M FILM ON EXISTING STOREFRONT WINDOWS AT ENTRANCE TOWER.

3. BAFFLE TRANSACTION WINDOWS IN LIEU OF SPEAKER TRANSACTION WINDOWS.

4. REPLACE/INSTALL NEW BLINDS

5. ACOUSTICAL WALL PANELS IN COURTROOM

DEDUCT ALTERNATES:

1. VCT IN LIEU OF LVT IN CORRIDORS AND BREAKROOMS.

2. REMOVE 2ND & 3RD FLOOR BREAKROOMS FROM SCOPE.

3. REMOVER TOWER STAIRWELL FROM SCOPE.

SHEET # SHEET NAME

ISSUE

DATE

CURRENT

REV.

AUDIO / VISUAL

AV000 AV SYSTEMS LEGEND 12/12/25

AV002 AV SYSTEMS - JUVENILE COURT 259A 12/12/25

AV003 AV SYSTEMS - DIGITAL SIGNAGE & CONFERENCE

ROOM

12/12/25

AV100 AV SYSTEMS WALL PLATE 12/12/25

AV INFRASTRUCTURE

AVI000 AV INFRASTRUCTURE LEGEND 12/12/25

AVI100 AV INFRASTRUCTURE FLOOR PLANS - 1ST FLOOR 12/12/25

AVI101 AV INFRASTRUCTURE FLOOR PLANS - 2ND FLOOR 12/12/25

AVI102 AV INFRASTRUCTURE FLOOR PLANS - 3RD FLOOR 12/12/25

AVI200 AV INFRASTRUCTURE RCP - 1ST FLOOR 12/12/25

AVI201 AV INFRASTRUCTURE RCP - 2ND FLOOR 12/12/25

AVI202 AV INFRASTRUCTURE RCP - 3RD FLOOR 12/12/25

AVI300 AV INFRASTRUCTURE ELEVATIONS 12/12/25

AVI400 AV INFRASTRUCTURE DETAILS 12/12/25

TELECOM

T001 TELECOM LEGEND 12/12/25

T100 TELECOM PROPOSED FLOOR PLANS - 1ST FLOOR 12/12/25

T101 TELECOM PROPOSED FLOOR PLANS - 2ND FLOOR 12/12/25

T102 TELECOM PROPOSED FLOOR PLANS - 3RD FLOOR 12/12/25

T400 TELECOM DETAILS 12/12/25

T401 TELECOM DETAILS 12/12/25

T601 TELECOM RISER DIAGRAMS 12/12/25

TD000 TELECOM DEMOLITION PLAN - 1ST FLOOR 12/12/25

TD001 TELECOM DEMOLITION PLAN - 2ND FLOOR 12/12/25

TD002 TELECOM DEMOLITION PLAN - 3RD FLOOR 12/12/25

SECURITY

SC001 SECURITY LEGEND AND NOTES 12/12/25

SC100 SECURITY PROPOSED FLOOR PLANS - 1ST FLOOR 12/12/25

SC101 SECURITY PROPOSED FLOOR PLANS - 2ND FLOOR 12/12/25

SC102 SECURITY PROPOSED FLOOR PLANS - 3RD FLOOR 12/12/25

SC400 SECURITY DOOR DETAILS 12/12/25

SC401 SECURITY CAMERA DETAILS 12/12/25

PLUMBING

P001 PLUMBING - NOTES, LEGENDS & SCHEDULES 12/12/25

P002 TYP. PLUMBING DETAILS 12/12/25

P101 PLUMBING PLAN - FIRST FLOOR 12/12/25

P201 PLUMBING PLAN - SECOND FLOOR 12/12/25

P301 PLUMBING PLAN - THIRD FLOOR 12/12/25

P401 PLUMBING SPECIFICATIONS 12/12/25

N o

D

E S

C R

IP

T

IO

N

D A

T E

P

R E

-B

ID

A D

D E

N D

U M

/0

/2

A. LIMITING HEIGHT, STUD GAUGE AND SPACING INFORMATION PROVIDED IN PARTITION SCHEDULES ARE ABBREVIATED AND MAY NOT ADDRESS ALL CONDITIONS OF THE PROJECT. THIS INFORMATION IS

PROVIDED FOR USE AS A GUIDE AND DOES NOT ALLEVIATE THE CONTRACTOR FROM PROVIDING

WALL ASSEMBLIES THAT MEET THE DESIGN CRITERIA FOR EACH CONDITION. CONTRACTOR SHALL

COORDINATE WITH PROJECT CONDITIONS AND PROVIDE WALL ASSEMBLIES BASED ON

MANUFACTURER'S STANDARD SPAN TABLES THAT MEET DESIGN CRITERIA INCLUDING: LOADS,

DEFLECTION LIMITS, FIRE TEST RATINGS AND SOUND TEST CLASSIFICATIONS.

B. SOUND TRANSMISSION CLASS (STC) INDICATED IS BASED ON MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE IN SOUND TEST ASSEMBLY SCHEDULED. IF CHANGES IN THE ASSEMBLY ARE

NECESSARY DUE TO CONTRACTOR'S SELECTION OF PRODUCTS/MANUFACTURER OR DUE TO

REQUIRED PARTITION HEIGHT, DEFLECTION CRITERIA OR DESIGN PRESSURE, CONTRACTOR SHALL SUBMIT FOR APPROVAL AND PROVIDE ALTERNATE PARTITION ASSEMBLIES THAT MEET SPECIFIED DESIGN CRITERIA. FIELD SOUND TRANSMISSION (FSTC) IS PERMITTED TO BE 5 POINTS LOWER THAN

SPECIFIED STC.

C. IF THE SELECTED STEEL STUD MANUFACTURER'S THICKNESS OF STEEL COMPONENT VARIES FROM THE BASIS OF DESIGN (AS DEFINED BELOW) OR HAS OTHER ATTRIBUTES THAT VARY FROM THE BASIS OF DESIGN, PROVIDE MANUFACTURER'S STANDARD THICKNESS WITH LIMITING HEIGHT SPAN TABLES

THAT MEETS OR EXCEEDS THE SPECIFIED DESIGN CRITERIA.

D. PARTITIONS SHALL EXTEND 6" PAST FINISHED CEILING, U.N.O

E. RATED PARTITIONS SHALL BE PERMANENTLY IDENTIFIED IN CONCEALED SPACES EITHER AS

REQUIRED BY CODE OR WITH 2" HIGH LETTERING IN A COLOR/VALUE CONTRASTING WITH THE

BACKGROUND AND SPACE NO MORE THAN 12 FEET ON CENTER. TEXT SHALL READ AS REQUIRED BY CODE OFFICIAL OR AS"_____ HOUR FIRE & SMOKE BARRIER - PROTECT ALL OPENINGS." (FILL IN

APPROPRIATE HOURLY RATING)

F. GYPSUM WALL BOARD IS TO BE TYPE 'X' FIRE RESISTANT BOARD UNLESS OTHERWISE NOTED.

G. DOOR OPENING FRAMING (WHETHER RATED OR NON - RATED) SHALL BE MINIMUM 20 GAGE STUDS

WITH SINGLE STUD JAMB FOR STANDARD WEIGHT DOORS AND DOUBLE STUD JAMB FOR HEAVY

WEIGHT DOORS IN ACCORDANCE WITH GYPSUM ASSOCIATION STANDARD GA-219.

H. ALL FIRE AND/OR SMOKE BARRIERS OR WALLS SHALL BE EFFECTIVELY ANDPERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING ABOVE A DECORATIVE CEILING AND/OR IN CONCEALED SPACES WITH LETTERS A MINIMUM OF 2" HIGH ON A CONTRASTING BACKGROUND SPACED A MAXIMUM OF 12'-0" ON CENTER WITH A MINIMUM OF ONE PER WALL OR BARRIER. THE HOURLY RATING SHALL BE INCLUDED ON ALL RATED BARRIERS OR WALLS. SUGGESTED WORDING ‘(__) HOUR FIRE AND SMOKE BARRIER-

PROTECT ALL OPENINGS.

a. EXCEPTION: EXISTING STENCILING ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.” AS

STATED IN THE RULES AND REGULATIONS OF THE SAFETY FIRE COMMISSIONER CHAPTER 120-3-3

RULES AND REGULATIONS FOR THE STATE MINIMUM FIRE SAFETY STANDARDS.

b. APPLY LETTERING TO BOTH SIDES OF WALLS.

I. ALL FIRE RATED PARTITIONS ARE REQUIRED TO GO TO THE BOTTOM OF STRUCTURAL DECK, U.N.O

J. IN ALL WET AREAS USE 5/8" MOLD AND MOSISTURE RESISTANT DRYWALL PANELS. SUBSTITUTE

SCHEDULED GYPSUM BOARD WITH WATER RESISTANT BACKING PANEL GYPSUM BOARD OF EQUAL

THICKNESS & EQUAL FIRE RATING IN AREAS TO RECEIVE TILE.

GENERAL NOTES:

CONSTRUCTION AND LOCATION MAXIMUM SINGLE DIMENSION MAXIMUM SINGLE AREA

PARTITION - INTERIOR

CEILING - INTERIOR

WITH PERIMETER RELIEF

WITHOUT PERIMETER RELIEF

30' - 0"

50' - 0"

30' - 0"

2,500 S.F.

900 S.F.

NOTE: ANY REQUIRED CONTROL JOINTS NOT SHOWN OR LOCATED IN THE DRAWINGS SHALL BE

FIELD COORDINATED WITH THE ARCHITECT PRIOR TO FINAL INSTALLATION

STRUCTURE ABOVE

FINISHED CEILING

CONTROL JOINTS REFERENCE CONTROL

JOINTS DETAILS FOR INFORMATION

SCHEDULED WALL BASE

SCHEDULED FINISH FLOOR

MAXIMUM SPACING - CONTROL JOINTS

GYPSUM BOARD CONTROL JOINTS

GYPSUM BOARD CONTROL JOINTS - PLACEMENT DIAGRAMS

2S438SW

HOURLY RATING

CORE STRUCTURE

OVERALL PARTITION THICKNESS

MODIFICATION CODE(S)

HOURLY RATING CODE STRUCTURE

S

S

W

M

F

X

C

0 HOUR

1 HOUR

2 HOUR

3 HOUR

4 HOUR

SMOKE

STEEL STUD

WOOD STUD

CONCRETE MASONARY UNIT

FURRING

SHAFT WALL - STEEL STUD

CHASE WALL

MODIFICATION CODES

WALL TAG

S SOUND ATTENUATION REQUIRED TO CONTINUE THE FULL HEIGHT OF THE WALL –

COMPLY WITH SCHEDULED STC RATING & TESTING ASSEMBLY REQUIREMENTS.

A EXTEND PARTITION TO UNDERSIDE OF DECK ABOVE

C EXTEND PARTITION TO UNDERSIDE OF FINISH CEILING, ADD SOUND ATTENUATION

ABOVE CEILING - REFER TO "C" MODIFIER DETAIL FOR ADDITIONAL INFORMATION

U NOT USED

P NOT USED

M NOT USED

K NOT USED

CIP CAST IN PLACE CONCRETE WALL, REFER TO TABLE IBC CH 721.1(2) FOR RATING

TYPICAL WALL TYPE BEGINS AT THE EXISTING SLAB AND EXTENDS 6" PAST FINISHED

CEILING, U.N.O. BELOW. - REFER TO "A" MODIFIER DETAIL FOR ADDITIONAL INFORMATION

B NOT USED

STRUCTURE ABOVE

SCHEDULED PARTITION

"A" MODIFIER - PARTIAL HEIGHT FINISH

SCHEDULED CEILINGS

EXTEND METAL STUDS TO

STRUCTURE ABOVE

EXTEND GYPSUM WALLBOARD

6" ABOVE FINISHED CEILING

.0

BRACING TO STRUCTURE ABOVE

EXTEND FRAMING AND GYPSUM

WALLBOARD 6" ABOVE FINISHED

CEILING

SCHEDULED CEILING

SCHEDULED PARTITION

"Y" MODIFIER - PARTIAL HEIGHT PARTITION

BRACE TO STRUCTURE

STRUCTURE ABOVE

WHERE USED WITH "S" MODIFIER,

PROVIDE 3" SOUND ATTENUATION

BLANKET, EXTENDED 4' - 0"

MINIMUM EACH SIDE OF WALL

SCHEDULED CEILING

WHERE USED WITH "S" MODIFIER,

COMPLY WITH REFERENCE STC

TESTED ASSEMBLY REQUIREMENTS

IN SCHEDULED PARTITION TYPE

SCHEDULED PARTITION

"C" MODIFIER - PARTITION TO FINISH CEILING

FIRESTOP SEALANT EACH SIDE

2" WIDE 16 GA. GALV. STEEL

STRAPS AT 24" O.C. MAX

FIRE SAFING INSULATION FILL

T.O. GYP. BD. EACH SIDE

FIRE SAFING INSULATION FILL

METAL DECK FLUTES

EXISTING FLOOR DECK

W/CONCRETE FILL

CUT STUDS SHORT AS

REQD. BY U.L DESIGN

1 LAYER TYPE X GYP. BD.

FOR 1 HR, 2LAYERS TYPE X

GYP. BD. FOR 2 HR; REFER TO

SCHEDULED PARTITION FOR

ADDITIONAL INFORMATION

BASIS OF DESIGN: U.L. NO. HW - D - 0360

FIRESTOP SEALANT BEYOND

FIRE SAFING INSULATION FILL

T.O. GYP. BD. EACH SIDE

FIRE SAFING INSULATION AT

DECK FLUTE BEYOND

STEEL FLOOR DECK

W/CONCRETE FILL

CUT STUDS SHORT AS

REQD. BY U.L DESIGN

1 LAYER TYPE X GYP. BD.

FOR 1 HR, 2 LAYERS TYPE X

GYP. BD. FOR 2 HR; REFER TO

SCHEDULED PARTITION FOR

ADDITIONAL INFORMATION

BASIS OF DESIGN: U.L. NO. HW - D - 0091

FIRESTOP SEALANT EACH SIDE

PLAN

BASE

HEAD

CONT TRACK WITH (2) PAF AT 16" O.C. MAX. WITHIN

1" OF ENDS.

SLIP-TYPE CONNECTION BETWEEN TOP TRACK

AND STUDS; ALLOW FOR 1/2" MIN. CLEARANCE

CONT. FIRESTOPPING; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

1 LAYER 5/8" GYP. BD. ON EACH SIDE; REFER TO

TYPES BELOW FOR EXACT DESCRIPTION

METAL STUD FRAMING AS SPECIFIED

CONT. FIRE STOPPING; REFER TO TYPES

BELOW FOR EXACT DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE FINISH

UNLESS INDICATED OTHERWISE

CONT. METAL STUD RUNNER WITH FASTENERS AT

2'-0" O.C. MAX. AND WITHIN 1" OF ENDS

COORDINATE SOUND ATTENUATION BLANKET

(SAB) WITH PARTITION TYPE BELOW

PLAN

BASE

HEAD

CONT. 20 GA MIN. WITH (2) PAF AT 16" O.C. MAX.

WITHIN 1" OF ENDS.

SLIP-TYPE CONNECTION BETWEEN TOP TRACK

AND STUDS; ALLOW FOR 1/2" MIN. CLEARANCE

CONT. FIRESTOPPING; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

1 LAYER 5/8" GYP. BD. ON ONE SIDE; REFER TO

TYPES BELOW FOR EXACT DESCRIPTION

METAL SHAFT STUD STUD AT 16" O.C. CONT. ROW

OF BLOCKING AT 4'-0" O.C.

CONT. SEALANT; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE FINISH

UNLESS INDICATED OTHERWISE

CONT. METAL STUD RUNNER WITH FASTENERS AT

2'-0" O.C. MAX. AND WITHIN 1" OF ENDS

COORDINATE SOUND ATTENUATION BLANKET

(SAB) WITH PARTITION TYPE BELOW

PLAN

BASE

HEAD SLIP-TYPE CONNECTION BETWEEN TOP TRACK

AND STUDS; ALLOW FOR 1/2" MIN. CLEARANCE

CONT. SEALANT OR FIRESTOPPING; REFER TO

TYPES BELOW FOR EXACT DESCRIPTION

1 LAYER 5/8" GYP. BD. ON EACH EXTERIOR SIDE;

REFER TO TYPES BELOW FOR EXACT DESCRIPTION

METAL STUD FRAMING AS SPECIFIED

CONT. SEALANT; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE FINISH

UNLESS INDICATED OTHERWISE

CONT. METAL STUD RUNNER WITH FASTENERS

WITHIN 1" OF ENDS

COORDINATE SOUND ATTENUATION BLANKET

(SAB) WITH PARTITION TYPE BELOW

PROVIDE 1" CLEAR GAP BETWEEN PLUMBING AND

ONE WALL. DO NOT BRACE BETWEEN STUDS

PLAN

BASE

HEAD

LINE OF SUBSTRATE

CONT. SEALANT OR

FIRESTOPPING; REFER

TO TYPES BELOW FOR

EXACT DESCRIPTION

1 LAYER FINISH MATERIAL

ON ONE SIDE; REFER TO

TYPES BELOW FOR EXACT

DESCRIPTION

METAL FURRING

STRIPS, REFER TO

TYPES BELOW

CONT. SEALANT;

REFER TO TYPES

BELOW FOR EXACT

DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE

FINISH UNLESS INDICATED OTHERWISE

PLAN

BASE

HEAD LINE OF SUBSTRATE

CONT. SEALANT OR FIRESTOPPING

1 LAYER 5/8" GYP. BD. ON ONE SIDE

METAL STUD FRAMING AS SPECIFIED

CONT. SEALANT; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE FINISH

UNLESS INDICATED OTHERWISE

COORDINATE SOUND ATTENUATION BLANKET

(SAB)

PLAN

BASE

HEAD

CONT. FIRESTOPPING; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

CONT. FIRE STOPPING; REFER TO TYPES

BELOW FOR EXACT DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE FINISH

UNLESS INDICATED OTHERWISE

8" NOMINAL CMU

UNDERSIDE OF DECK/STRUCTURE

1 LAYER 1" GYP. BD. ON SHAFT SIDE; REFER TO

TYPES BELOW FOR EXACT DESCRIPTION

PLAN

BASE

HEAD LINE OF SUBSTRATE

CONT. SEALANT OR FIRESTOPPING; REFER TO

TYPES BELOW FOR EXACT DESCRIPTION

2 LAYERS 5/8" GYP. BD. ON ONE SIDE

METAL STUD FRAMING AS SPECIFIED

CONT. SEALANT; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE FINISH

UNLESS INDICATED OTHERWISE

COORDINATE SOUND ATTENUATION BLANKET

(SAB) WITH PARTITION TYPE BELOW

PLAN

BASE

HEAD

Z-FURRING CHANNELSHAT-FURRING CHANNELS

PAINT CMU AS SCHEDULED REFER TO FINISH

SCHEDULE

RESILIENT SOUND ISOLATION CLIP SPACED @ 24" O.C.

DRYWALL FURRING CHANNEL @ 24" O.C.

2 LAYERS 5/8" GYP. BD. ON ONE EXTERIOR SIDE;

REFER TO TYPES BELOW FOR EXACT DESCRIPTION

1 LAYER 5/8" GYP. BD. ON ONE SIDE; REFER TO TYPES

BELOW FOR EXACT DESCRIPTION. USED WITH UL U429

PLAN

BASE

HEAD CONT. FIRESTOPPING; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

CONT. FIRE STOPPING; REFER TO TYPES

BELOW FOR EXACT DESCRIPTION

TOP OF SLAB

8" NOMINAL CMU

UNDERSIDE OF DECK/STRUCTURE

2-1/2" 20 GA METASL STUD STUDS AT 16" O.C.

11"

1" AIR SPACES BETWEEN CMU AND STUD WALL

1 LAYER 5/8" GYP. BD. ON ONE SIDE; REFER TO

TYPES BELOW FOR EXACT DESCRIPTION

NOTE: WALL TYPE TO BE COORDINATED WITH SLAB REMOVAL.

PLAN

BASE

HEAD

CONT. FIRESTOPPING; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

CONT. FIRE STOPPING; REFER TO TYPES

BELOW FOR EXACT DESCRIPTION

TOP OF FLOOR LEVEL TO RECEIVE FINISH

UNLESS INDICATED OTHERWISE

4" NOMINAL CMU

UNDERSIDE OF DECK/STRUCTURE

PAINT CMU AS SCHEDULED REFER TO FINISH

SCHEDULE

PROVIDE 1" CLEAR GAP BETWEEN PLUMBING AND

ONE WALL. DO NOT BRACE BETWEEN STUDS

NOTE: WALL TYPE TO BE COORDINATED WITH SLAB REMOVAL.

ADDITIONAL LAYER 5/8" GYP. BD. ON EACH SIDE

FOR 2 HR PARTITIONS; REFER TO TYPES BELOW

FOR EXACT DESCRIPTION

NOTE: SEE STRUCT. DWGS FOR WALL-TO-FLOOR CONNECTION.

NOTE: SEE STRUCT. DWGS FOR WALL-TO-FLOOR CONNECTION.

ADDITIONAL LAYER 5/8" GYP. BD. FOR 1 HR

PARTITIONS, SECURE WITH A LAYER OF SETTING-

TYPE JOINT COMPOUND; REFER TO TYPES

BELOW FOR EXACT DESCRIPTION

HINGE

FRAME

METAL STUD

DOOR

FIRE RESISTANT MATERIAL

DOUBLE WALL CONSTRUCTION

TYPE X GYPSUM

SCALE

DATE:

DRAWN BY:

CHECKED BY:

PROJECT #

THIS DRAWING IS AN INSTRUMENT OF

SERVICE AND SHALL REMAIN THE

PROPERTY OF THE ARCHITECT. NO

PART OF THIS DOCUMENT SHALL BE

REPRODUCED OR TRANSMITTED IN

ANY FORM, ELECTRONICALLY OR

MECHANICALLY, FOR ANY PURPOSE,

WITHOUT THE EXPRESS WRITTEN

PERMISSION OF THE ARCHITECT.

M

A R

IE

T

T A

S T

R E

E T

N

W U

N

IT

A

T L A

N T

A

G E

O R

G

IA

T

F w w w .s iz e m o re g ro u p

.c o m

S

IZ

E

M O

R E

G R

O U

P

12/12/25

As indicated

3/5/2026 11:41:29 AMAutodesk Docs://24260FLOLEC_Floyd_County_Law_Enforcement_Center/24260SLOYLEC_Floyd_County_LEC.rvt

G400

PARTITION

TYPES

Checker

Author

12/12/25

24260FLOLEC

F L O

Y D

C O

U N

T Y

L E

C R

E N

O V

A T

IO

N

G

O V

E R

N M

E N

T P

L A

Z A

R O

M E

G

A

100% CONSTRUCTION DOCUMENTS

3" = 1'-0"G400

2 HEAD WALL DETAILS AT STEEL DECK A - 1 & 2 HR

3" = 1'-0"G400

3 HEAD WALL DETAILS AT STEEL DECK B - 1 & 2 HR

WALL TYPE - CONCRETE MASONRY UNIT CHASE PARTITION

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

0M1914A 1'-7 1/4" 8"

WALL TYPE - METAL FRAMED FURRING PARTITION - (1) LAYER GYPSUM

BOARD, ONE SIDE ONLY

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

0F414 4 1/4" 3 5/8"

0F414AS 4 1/4" 3 5/8"

1F478AS 4 7/8" 3 5/8" 1-HR V497

WALL TYPE - METAL FRAMED FURRING CHANNEL PARTITION - (1) LAYER

GYPSUM BOARD, ONE SIDE ONLY

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

WALL TYPE - METAL FRAMED PARTITION - (1) LAYER GYPSUM BOARD, EACH

SIDE

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

0S478 4 7/8" 3 5/8" U419 40 USG-860808 0"

0S478AS 4 7/8" 3 5/8" U419 50 CK 654-40 3 5/8"

0S478S 4 7/8" 3 5/8" U419 50 CK 654-40 3 5/8"

1S478AS 4 7/8" 3 5/8" 1-HR U419 50 CK 654-40 3 5/8"

2S618A 6 1/8" 3 5/8" 2-HR U419

WALL TYPE - METAL FRAMED CHASE PARTITION - (1) LAYER GYPSUM

BOARD, BOTH SIDES

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

0C658AS 1'-4 1/2" 8" 60 TL-93-309 3 5/8"

WALL TYPE - METAL FRAMED SHAFT PARTITION - (1) LAYER SHAFT LINER ON

SHAFT SIDE WITH (1) LAYER GYPSUM BOARD ON THE OTHER SIDE

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

1X414A 4 1/8" 4" 1-HR U336, V473

2X434A 4 3/4" 4" 2-HR U415

WALL TYPE - CONCRETE MASONRY UNIT

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

0M758A 7 5/8" 7 5/8"

1M758A 7 5/8" 7 5/8" 2-HR U905

WALL TYPE - CONCRETE MASONRY UNIT - (1) LAYER GYPSUM BOARD, ONE

SIDE ONLY

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

1M1034 10 3/4" 2-HR U905

3" = 1'-0"G400

1 FEC RATING @ COURTROOM

WALL TYPE - CONCRETE MASONRY UNIT CHASE PARTITION

TAG

WIDTH FIRE SOUND MODIFIER

TTL CORE RATING TEST STC TEST SAB

0M1914A 1'-7 1/4" 8"

N o

D

E S

C R

IP

T

IO

N

D A

T E

P

R E

-B

ID

A D

D E

N D

U M

/0

/2

A

AV

AX

AZZ

AZ

B

BX

C

CX

D

AW

UP

DOWN

NOT IN SCOPE

NOT IN SCOPE

NOT IN SCOPE

DETENTION

VESTIBULE

STOR

VESTIBULE

FILES

VESTIBULE

MUNCIPAL

COURTROOM

MEN LEDGE

VESTWOMEN'S

LOCKERS

MENS

LOCKERS

OFFICE

TASK

FORCE

ELECTRICAL

ELECTRONICS

CORRIDOR

ELEVATOR

EQUIPMENT

ELEVATOR

TELEPHONE

DATA

JANITOR INTOXILYZER CORRIDOR SERGEANT

DARK ROOM

LABORATORY

EVIDENCE

COURT

CLERK

CORRIDOR

SERGEANT

PUBLIC

WOMEN

VESTIBULE

CORRIDOR

PUBLIC MEN

ID/

PASSPORT

RECORDS

TECH

FILES FILES/

COUNTRY

RECORDS

FILE

SERVER

LOBBY

STAIRS

ELEVATOR

EQUIPMENT

CORRIDOR

FITNESS

RECORD

FITNESS

ROOM

CORRIDORCORRIDOR

VEST

WOMEN

CORRIDOR

PROBATION

STAIR

CITY

RECORDS

A510

RELOCATED PLANTER BOX

S01

S02

1M1034

8'-8"

6' -1

1" E104

E101

1X414A

2X434A

NOTE: MAINTAIN ESSENTIAL DATA LINES &

CONNECTIONS FOR DURATION OF DEMOLITION &

CONSTRUCTION (TO BE COORDINATED W/ OWNER)

11' - 10"

DEMO CONCRETE AS NEEDED

FOR INSTALLATION OF HELICAL

PIERS. REPAIR AND INFILL TO

MATCH EXISTING SLOPE,

PATTERN AND THICKNESS

AFTER INSTALLATION. STRUCT.

DWGS.

PROVIDE FIREMAN'S

EMERGENCY KEY BOX.

(KNOXBOX 3200)

ALIGN

NOTE: DEMO AS NEEDED TO INSTALL NEW STRUCTURE

UNDERNEATH PROPOSED HOLDING CELLS ON 2ND LEVEL.

SALVAGE FIXTURES, PARTITIONS, CEILING GRID, LIGHT

FIXTURES, AND FLOORING TO BE REINSTALLED AFTER

INSTALLATION OF STRUCTURE.

HELICAL PIER LOCATIONS. SEE

STRUCT. DWGS.

C R

C R

2S618A

KEY PAD AT ELEVATOR DOOR - SEE AV DRAWINGS

1. CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT

PARTITIONS, EXIT ENCLOSURES, AND FIRE WALLS SHALL BE

EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR

STENCILING ABOVE ANY DECORATIVE CEILING AND / OR IN CONCEALED

SPACE WITH LETTERS "A" MINIMUM OF TWO INCHES HIGH ON A

CONTRASTING BACKGROUND SPACED A MAXIMUM OF TWELVE FEET ON

CENTER WITH A MINIMUM OF ONE PER WALL OR BARRIER. THE HOURLY

FIRE RATING SHALL BE INCLUDED ON ALL RATED BARRIER OR WALLS.

SUGGESTED WORDING ( ) HOUR -- FIRE AND SMOKE BARRIER-PROTECT

ALL OPENINGS.

2. ALL VERTICAL PIPING EXPOSED IN ROOMS SHALL BE FURRED WITH

SAME MATERIAL AS ADJACENT WALLS. EXCEPTIONS ARE: MECHANICAL

ROOMS, ELECTRICAL ROOMS, TELEPHONE ROOMS.

3. METAL STUD PARTITIONS BEHIND ALL PLUMBING AND OTHER FIXTURES

SHALL BE BRACED TO STRUCTURE WHERE REQUIRED TO SUPPORT THE

EQUIPMENT PROVIDED.

4. DO NOT SCALE DRAWINGS. ALL DIMENSIONS AND CONDITIONS

INDICATED IN THESE DOCUMENTS MUST BE FIELD VERIFIED PRIOR TO

CONSTRUCTION. FOR DIMENSIONS NOT SHOWN OR IN QUESTION,

6. NEW GYPSUM BOARD CONSTRUCTION MEETING EXISTING GYPSUM

BOARD CONSTRUCTION IN THE SAME SHALL BE FLUSH WITH NO

VISIBLE JOINTS SHOWING.

7. PROVIDE COAT HOOK BEHIND DOORS IN ALL PRIVATE OFFICES, SINGLE

HOOK TYPE.

8. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY.

9. UNLESS OTHERWISE NOTED, INTERIOR PARTITION DIMENSIONS ARE

GIVEN FACE OF FINISH SURFACE TO FACE OF FINISH SURFACE.

10. ELECTRIC PANELS, ALARM BOXES, FIRE EQUIPMENT CABINETS AND

OTHER RECESSED BOXES GREATER THAN 16 SQUARE INCHES THAT

ARE LOCATED IN RATED WALLS SHALL BE BACKED BY GYPSUM

WALLBOARD LAYERS SUFFICIENT TO MAINTAIN THE DESIGNATED

RATING.

11. ALL EXISTING WORK, FURNISHINGS, EQUIPMENT OR MATERIAL TO

REMAIN THAT ARE DAMAGED BY CONTRACTOR'S OPERATION UNDER

SPACING OF METAL STUDS FOR ALL CONDITIONS.

13. CEILING ACCESS PANELS SHALL BE PROVIDED IN NON-ACCESSABLE

C. MIXING BOXES

D. POWER OPERATED DAMPERS

E. ACCESS PANELS IN DUCTWORK

F. VOLUME AND BALANCING DEVICES

G. WATER FLOW SWITCHES

H. SPRINKLER SYSTEM DRAINS AND TEST CONNECTIONS

I. PRESSURE SWITCHES

14. ALL FURNITURE BY OTHERS; NOT IN CONTRACT (N.I.C.) U.N.O.

15. ALL GYPSUM BOARD SHALL BE 5/8" THICK; PROVIDE CORNER

REINFORCEMENT AT ALL EXPOSED OUTSIDE CORNERS. EXCEPTION -

GYPSUM BOARD MAY BE ALTERNATE THICKNESS AT CONDITIONS

REQUIRING NEW CONSTRUCTION TO BE FLUSH WITH EXISTING.

16. PROVIDE SOLID WOOD BLOCKING INSIDE PARTITIONS FOR SECURING

WALL HUNG CABINETS/MILLWORK, SHELVING AND WALL HUNG

ACCESSORIES.

17. ALL DRYWALL FINISH WORK TO BE FINISH LEVEL 4, U.N.O.

18. ALL INTERIOR PARTITIONS TO BE TYPE 0S478, U.N.O.

19. ALL ANGLES ARE 90 DEGREES, U.N.O.

20. WHEN DIFFERENT PARTITION TYPES ARE LOCATED ADJACENT TO ONE

ANOTHER, THE FINISHED FACES OF THE PARTITIONS SHALL BE ALIGNED

AND FLUSH, U.N.O.

21. LOCATE EDGE OF DOOR OPENINGS 6" FROM INSIDE FACE OF ADJACENT

PARTITION, U.N.O.

22. CONTRACTOR TO PATCH ALL HOLES, SAND AND PAINT ALL WALLS

WITHIN SCOPE.

23. HOLDINGS CELLS TO BE ENTIRELY TAMPER PROOF AND LIGATURE FREE.

24. HOLDING CELL BENCHES TO BE:

DDS DETENTION BED 7504L/R-M5

POWDER COATED

EXISTING CONSTRUCTION TO REMAIN

NEW PARTITION

NEW PARTITION (MASONRY)

SCALE

DATE:

DRAWN BY:

CHECKED BY:

PROJECT #

THIS DRAWING IS AN INSTRUMENT OF

SERVICE AND SHALL REMAIN THE

PROPERTY OF THE ARCHITECT. NO

PART OF THIS DOCUMENT SHALL BE

REPRODUCED OR TRANSMITTED IN

ANY FORM, ELECTRONICALLY OR

MECHANICALLY, FOR ANY PURPOSE,

WITHOUT THE EXPRESS WRITTEN

PERMISSION OF THE ARCHITECT.

M

A R

IE

T

T A

S T

R E

E T

N

W U

N

IT

A

T L A

N T

A

G E

O R

G

IA

T

F w w w .s iz e m o re g ro u p

.c o m

S

IZ

E

M O

R E

G R

O U

P

12/12/25

1/8" = 1'-0"

3/5/2026 11:41:06 AMAutodesk Docs://24260FLOLEC_Floyd_County_Law_Enforcement_Center/24260SLOYLEC_Floyd_County_LEC.rvt

A100

OVERALL

PROPOSED

FLOOR PLANS –

1ST FLOOR

SMG

IDV

12/12/25

24260FLOLEC

F L O

Y D

C O

U N

T Y

L E

C R

E N

O V

A T

IO

N

G

O V

E R

N M

E N

T P

L A

Z A

R O

M E

G

A

100% CONSTRUCTION DOCUMENTS

1/8" = 1'-0"A100

1 PROPOSED FLOOR PLANS - 1ST FLOOR

N

0 40' 60' 80'20'

Graphic Scale: 1 inch = 20 feet

GENERAL NOTES

LEGEND

N o

D

E S

C R

IP

T

IO

N

D A

T E

P

R E

-B

ID

A D

D E

N D

U M

/0

/2

DN

DN

1 1.9 2 3 4 5 5.5 6 6.2 6.4 7 7.5 7.9 8 8.3 8.5 8.8 9

A

AV

AX

AZZ

AZ

B

BX

C

CX

D

E

AW

SHERIFF

OFFICE

HOLDING

254A

COPY/PRINT/DOCUMENT

ASSEMBLY

LOBBY

STAIR

MEN'S RR

UP

DOWN

DOWN

HOLDING

254B

COURTROOM

SEATING

259B

ALIGN

ALIGN

A210

OFFICE

PUBLIC DEF.

STORAGE

CORRIDOR

ATTORNEY

MTG.

EQUIPMENT

STORAGE

PROBATION

CORRIDOR

RECEPTION

DEP. CLERK

DEP. CLERK

DEP. CLERK

CLERK

PROBATION

PROBATION

ATTORNEY

MTG

WOMEN'S

RR

WOMEN

MEN

JANITOR

OFFICE

ATTORNEY

MTG

COMMUNICATION

ROOM

BREAK

ROOM

SUPPLY

EQUIPMENT

SUPERVISOR

CONFERENCE

DIRECTORDIRECTOR

SECRETARY

CLOSET

CLOSET

TOILET

TOILET

OFFICE

LOBBY

OFFICE

OFFICE OFFICE OFFICE

ELECT.

TELEPHONE

/DATA

235A

BREAKROOM

STOR.

SHERIFF

BULLPEN

246A

STORAGE OFFICE

CORRIDOR

ELEVATOR

STAIR

BREAK

ROOM

CORRIDOR

CONFERENCE

ROOM

OFFICE

OFFICE

OFFICE

A400

A400

254A 254B

256A

256B

251B

251A

259A

E204

E263 E264

E272

E271

E265

E257

E282 E281 E280 E279 E278 E277 E276 E275 E274

E273

STORAGE

E258

SHERIFF

SUPERVISOR

246B

A510

0S478

0M758A

0M758A

0S478

0S478AS

/2

A210

1M1034NOT IN SCOPE

NOT IN SCOPE

0M758A

17'-7"2" 2"

7'-4"

0F414AS A402

ALIGN

A L

IG

N

0S478S

EQ EQ

13'-2"

259C

1X414A

2X434A

5'-3"

15'-6 1/2" 0 S

F

A

S

F

A

S

F

A

S

1F478AS

S

A

S

F

A

S

S

0S478

0C658AS

0S478

0S478S

0S478S

0S478S

8'-0"

0M1914A

259B E205

34H

42H

NOTE: 911 CALL CENTER TO REMAIN OPERATIONAL

FOR DURATION OF DEMOLITION & CONSTRUCTION

NOTE: MAINTAIN ESSENTIAL DATA LINES &

CONNECTIONS FOR DURATION OF DEMOLITION &

CONSTRUCTION (TO BE COORDINATED W/ OWNER)

6' - 6 1/2"

G400

A210

0S478S

F

S

A401

11' - 3 1/2"

/2 "9' - 6"

" 3' - 5"

A570

9"

INSTALL

ACCESS

DOOR

C R

C R

CR C

R

C R

CR

C R

CR

C R

C R

A210

COURTROOM

259A

C R

C R

C R

C R

CR

11' - 3"

4' - 8"

E232

E233

E267

5' - 3 1/2"

/2

A101

CR

CR

E261

0F414AS

0F414AS

0F414AS

0F414AS

0F414AS

A210

0F414AS

0F414AS

0S478AS

CELL BENCHES

3' - 4" 3' - 4"

1. CORRIDOR PARTITIONS, SMOKESTOP PARTITIONS, HORIZONTAL EXIT

PARTITIONS, EXIT ENCLOSURES, AND FIRE WALLS SHALL BE

EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR

STENCILING ABOVE ANY DECORATIVE CEILING AND / OR IN CONCEALED

SPACE WITH LETTERS "A" MINIMUM OF TWO INCHES HIGH ON A

CONTRASTING BACKGROUND SPACED A MAXIMUM OF TWELVE FEET ON

CENTER WITH A MINIMUM OF ONE PER WALL OR BARRIER. THE HOURLY

FIRE RATING SHALL BE INCLUDED ON ALL RATED BARRIER OR WALLS.

SUGGESTED WORDING ( ) HOUR -- FIRE AND SMOKE BARRIER-PROTECT

ALL OPENINGS.

2. ALL VERTICAL PIPING EXPOSED IN ROOMS SHALL BE FURRED WITH

SAME MATERIAL AS ADJACENT WALLS. EXCEPTIONS ARE: MECHANICAL

ROOMS, ELECTRICAL ROOMS, TELEPHONE ROOMS.

3. METAL STUD PARTITIONS BEHIND ALL PLUMBING AND OTHER FIXTURES

SHALL BE BRACED TO STRUCTURE WHERE REQUIRED TO SUPPORT THE

EQUIPMENT PROVIDED.

4. DO NOT SCALE DRAWINGS. ALL DIMENSIONS AND CONDITIONS

INDICATED IN THESE DOCUMENTS MUST BE FIELD VERIFIED PRIOR TO

CONSTRUCTION. FOR DIMENSIONS NOT SHOWN OR IN QUESTION,

6. NEW GYPSUM BOARD CONSTRUCTION MEETING EXISTING GYPSUM

BOARD CONSTRUCTION IN THE SAME SHALL BE FLUSH WITH NO

VISIBLE JOINTS SHOWING.

7. PROVIDE COAT HOOK BEHIND DOORS IN ALL PRIVATE OFFICES, SINGLE

HOOK TYPE.

8. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY.

9. UNLESS OTHERWISE NOTED, INTERIOR PARTITION DIMENSIONS ARE

GIVEN FACE OF FINISH SURFACE TO FACE OF FINISH SURFACE.

10. ELECTRIC PANELS, ALARM BOXES, FIRE EQUIPMENT CABINETS AND

OTHER RECESSED BOXES GREATER THAN 16 SQUARE INCHES THAT

ARE LOCATED IN RATED WALLS SHALL BE BACKED BY GYPSUM

WALLBOARD LAYERS SUFFICIENT TO MAINTAIN THE DESIGNATED

RATING.

11. ALL EXISTING WORK, FURNISHINGS, EQUIPMENT OR MATERIAL TO

REMAIN THAT ARE DAMAGED BY CONTRACTOR'S OPERATION UNDER

SPACING OF METAL STUDS FOR ALL CONDITIONS.

13. CEILING ACCESS PANELS SHALL BE PROVIDED IN NON-ACCESSABLE

C. MIXING BOXES

D. POWER OPERATED DAMPERS

E. ACCESS PANELS IN DUCTWORK

F. VOLUME AND BALANCING DEVICES

G. WATER FLOW SWITCHES

H. SPRINKLER SYSTEM DRAINS AND TEST CONNECTIONS

I. PRESSURE SWITCHES

14. ALL FURNITURE BY OTHERS; NOT IN CONTRACT (N.I.C.) U.N.O.

15. ALL GYPSUM BOARD SHALL BE 5/8" THICK; PROVIDE CORNER

REINFORCEMENT AT ALL EXPOSED OUTSIDE CORNERS. EXCEPTION -

GYPSUM BOARD MAY BE ALTERNATE THICKNESS AT CONDITIONS

REQUIRING NEW CONSTRUCTION TO BE FLUSH WITH EXISTING.

16. PROVIDE SOLID WOOD BLOCKING INSIDE PARTITIONS FOR SECURING

WALL HUNG CABINETS/MILLWORK, SHELVING AND WALL HUNG

ACCESSORIES.

17. ALL DRYWALL FINISH WORK TO BE FINISH LEVEL 4, U.N.O.

18. ALL INTERIOR PARTITIONS TO BE TYPE 0S478, U.N.O.

This is the start of the file's text. The full file is on GovTribe.