About this file
This is Addendum #3 to RFP #26-003 for the Law Enforcement Center Renovation, issued by Floyd County, Georgia Purchasing Department on February 26, 2026. The addendum provides clarifications and responses to bidder questions regarding the security systems expansion, door hardware specifications, structural design requirements, and HVAC considerations for the renovation project. Key clarifications include confirmation that the existing access control system is Honeywell NetAXS Model NX4L1 and the existing video surveillance system is Axis Communications with NVR Model AXIS S2208 running Program Version 6.14.11482 with cameras including AXIS models P3245-LV, P3227-LVE, Q3708-PVE, and P-3267-LVE; Floyd County prefers Axis equipment but will accept compatible systems with equal or better performance. The addendum also clarifies that detention door hardware set 8 has been revised to include prison-grade hinges (3 PH51 hinges), a Willoughby WSL-1100 Series mechanical mortise lock, and a heavy-duty floor stop rather than commercial-grade hardware, and confirms that door openings 251A, 256A, 256B, and 352 hardware specifications have been corrected with revised drawings attached. Additionally, the addendum notes that helical pier design is delegated to the successful bidder, who must submit signed and sealed drawings; bidders should assume normal soil conditions with geotechnical testing results available after bid submission; loads provided are service-level loads; and protective anti-corrosion coatings are required for the piers.
The addendum confirms that furniture is excluded from the General Contractor scope and specifies that all door hardware finishes should be 32D or 26D (Satin Stainless or Chrome), not US10B, with all hardware constructed of white metal and standard ADA-compliant Sargent "J" lever design to match existing hardware. The document includes a comprehensive door schedule detailing specifications for 89 door openings, including leaf type, frame type, materials, finishes, fire ratings, hardware sets, and security notes. HVAC requirements note that the contractor shall provide transfer openings above ceilings in new walls extending to deck to facilitate return air transfer to the main plenum. The revised door schedule and details are attached as part of this addendum, with corrections made to door heights (doors 251B and 259A corrected from 6'0" to standard 7'0" height) and hardware set assignments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ADDENDUM _4.pdf | ||
| 26_003 LAW ENFORCEMENT CENTER RENOVATIONS _ F.pdf | ||
| ADDENDUM _1.pdf | ||
| Pre_Bid Sign_in Sheet _ Floyd County LEC Reno.pdf | ||
| ADDENDUM _2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Twelve East Fourth Ave. Suite 106 ♦ ROME, GEORGIA 30161
PHONE (706) 291-5118
FLOYD COUNTY, GEORGIA
PURCHASING
TO: All Prospective Bidders: RFP #26-003 – “Law Enforcement Center Renovation”
FROM: Randy E. Self, Purchasing Director
SUBJECT: Q&A - No. 2
DATE: February 26, 2026
35. Current documents show to expand upon the existing access control and video surveillance systems. Can existing equipment/devices manufacturer information be provided to allow pricing of additional respective equipment/devices?
a. Access Control is Honeywell NetAXS, Model NX4L1
b. Video Surveillance is Axis Communications, NVR Name – AXIS S2208
36. We need clarification on the Security Systems. It states to expand the existing systems for the
Access Control and the Video Surveillance. What manufacturers do they currently have installed?
b. Video Surveillance is Axis Communications, NVR Name – AXIS S2208
37. The door schedule calls out hardware set 8 for the detention doors. Hardware set 8 lists commercial style door hardware and per the vendor would not be recommended for a detention grade door. The manufacturer's comments were the commercial hardware will not hold up on the heavier doors. Please advise.
a. Revision 1:
HEADING 8
DOORS # 254A, 254B
EACH DOOR TO HAVE:
3 PRISON HINGES PH51 (PBB)
1 LOCKSET WSL-1100 SERIES MECHANICAL MORTISE LOCK-LESS CORE
(WILLOUGHBY)
1 CYLINDER TO MATCH EXISTING MEDECO SYSTEM
1 HEAVY DUTY FLOOR STOP 542 (BURNS)
RANDY E. SELF AMANDA JENKINS SHARON PASLEY
PURCHASING DIRECTOR PURCHASING AGENT PURCHASING AGENT
ADDENDUM #3
38. Is there a geo report available for the helical piers?
a. A geotechnical engineer has been commissioned by the owner. Testing results will be available after submissions are due. Bidders are to assume normal soil conditions.
39. Please confirm connection method, length/pattern (layout/spacing, bolt vs weld) for helical piers.
a. Helical piers is a delegated design and the successful bidder for the helical piers will be responsible for the requested information
40. Please provide connection/base/cap details for the third floor HSS 5 x 5 x ¼
a. This question was answered in Addendum #2
41. Please confirm whether fabricator-stamped connections are required for C8 stiffeners, helical-pier angles, and brace seats.
a. Stamped connections for C8 stiffeners and angle brace seats are not required. The
Steel angle/bracket for the helical piers is a delegated design and the successful bidder for the helical piers must submit signed and sealed drawings for the helical pier design. This is noted on the Structural General Notes Item ( on S001)
42. Please advise/clarify the following information regarding the helical piers for this project. Is there a minimum depth requirement for the piers? Is a geotechnical/soils report available for review? Are the loads provided to be assumed as ultimate design load? Are protective / anti-corrosion coatings required for the piers?
a. A geotechnical engineer has been commissioned by the owner. Testing results will be available after submissions are due. Bidders are to assume normal soil conditions.
b. The noted loads are service level loads. As the Helical piers are embedded into ground it is expected that protective /anti-corrosion coating is required. The successful bidder for the helical piers should work with the geo-technical engineer / report to determine the depth to achieve the needed capacity that is noted on the drawings
43. What is the existing access control system (make, model, & software/license type)? What are the existing access control card readers being used? What is the existing CCTV VMS system (make, model, & software/license type)? What are the existing cameras being used (make, model)? Is there a camera manufacturer that Floyd would prefer to use?
a. Access Control is Honeywell NetAXS, Model NX4L1
b. Video Surveillance is Axis Communications, NVR Name – AXIS S2208, Program
Version – 6.14.11482
c. Camera models include AXIS: P3245-LV, P3227-LVE, Q3708-PVE, & P-3267-LVE
d. Floyd County’s preference is Axis. However, a system compatible with the existing equipment and with the same or better performance may be acceptable.
44. Is furniture excluded from the GC scope?
a. Yes
45. Openings 251A, 256A, 256B, and 352 do not have hardware sets defined. What hardware sets should be used for these openings?
a. The door schedule has been corrected to coordinate with the door hardware specs. Revised drawings are attached in this Addendum.
46. Openings 251B and 259A have height listed as 6’0”. Is this accurate or was this the combined width of the opening put in as the height?
a. This was a typo. The doors are the standard 7’-0” and has been corrected in drawings attached in this Addendum.
47. What lever design is wanted on the locks? Hardware Schedule does not call this out.
a. Standard ADA compliant lever. We want to match the existing on the suite as much as we can. Sargent "J" lever.
NOTE: The approved finish for the hardware should be 32D OR 26D (not US10B).
These are Satin Stainless or Chrome. All Hardware is to be white metal.
48. I’m looking for clarification on the security system work. It states to expand the existing systems for access control and video surveillance. What manufacturers do you currently have installed?
b. Video Surveillance is Axis Communications
HVAC Note: As required, contractor shall provide transfer openings above ceiling in new walls that go to deck in order for return air to transfer back to main plenum return. New walls may need a transfer opening for proper air return.
Thank you, Randy E. Self
Randy E. Self, Purchasing Director
Floyd County Board of Commissioners
NOT USED NOT USEDNOT USED
T FTEMPERED GLASS FIXED PANEL TK 10" TOE KICK MIN.
A B C D
SEE SCHEDULE
DOOR PANEL TYPES
DOOR/FRAME TYPE LEGEND
2" 2"
2"2"
DOOR
PANEL(S)
DOOR
PANEL(S)
2 3
STC:45
S E
E S
C H
E D
U L E
D O
O R
H E
IG
H
T
DOOR FRAME TYPES
DOOR COMMENTS
1. _____
F
3"
3"
SEE SCHEDULE
T
TK
GLAZING TYPE
C.2
ACCESS CONTROL
KP - ACCESS CONTROL CARD + PIN KEYPAD READER
M - MAGNETIC CONTACT
DR - REMOTE DOOR RELEASE
RX - REQUEST-TO-EXIT MOTION DETECTOR
RP - REQUEST-TO-EXIT PUSHBUTTON
ELECTRIFIED LOCKING HARDWARE
EL - ELECTRIC MORTISE LOCK WITH INTEGRAL REQUEST-TO-EXIT SWITCH
EE - ELECTRIFIED EXIT DEVICE WITH INTEGRAL REQUEST-TO-EXIT SWITCH
CX - MECHANICAL EXIT DEVICE WITH INTEGRAL REQUEST-TO-EXIT SWITCH
EA - ELECTRIFIED EXIT DEVICE WITH INTEGRATED AUDIBLE ALARM
CA - MECHANICAL EXIT DEVICE WITH INTEGRATED LOCAL ALARM
DE - DELATED EGRESS EXIT DEVICE
PT - ELECTRIC POWER TRANSFER
PS - LOCAL DOOR HARDWARE POWER SUPPLY FOR ELECTRIC LATCH RETRACTION TYPE LOCKING HARDWARE
DO - ADA DOOR OPERATOR
DA - ADA DOOR OPERATOR ACTUATOR BUTTON
SECURITY NOTES (FOR COORDINATION ONLY, REFER TO SECURITY DWGS FOR SPECS & LOCATIONS)
SEE SCHEDULE
1' - 0"
1' - 0"
SG
(+-) 1/2" THK MAR RESISTANT
PALYCARBONATE, LVL 2, 60 MIN ATTACK
RESISTANT
SG
SCHEDULED DOOR
SCHEDULED PARTITION
BLOCK AND SHIM AS REQUIRED
CONT. SEALANT BOTH SIDES
HOLLOW METAL DOOR FRAME
6"
SCHEDULED DOOR
HOLLOW METAL DOOR FRAME
CONT. SEALANT BOTH SIDES
SCHEDULED PARTITION
CMU BULLNOSE
AT JAMB
6"
VARIES
2" 2"
SCHEDULED PARTITION
HOLLOW METAL DOOR
FRAME
SCHEDULED DOOR
/2
6" BOX BEAM METAL STUD HEADER
CONT. SEALANT AROUND
PERIMETER; BOTH SIDES
NOTE:
REFER TO DRAWINGS AND
SPECIFICATIONS FOR DOOR
AND FRAME HARDWARE
VARIES
M
IN
1/2" 1/2"
VARIES
2" 2"
M
IN
M
IN
1/2"
VARIES
1/2"
SCHEDULED PARTITION
HOLLOW METAL DOOR
FRAME
SCHEDULED DOOR
/2
DOUBLE METAL STUD AT JAMB
CONT. SEALANT AROUND
PERIMETER; BOTH SIDES
JAMB ANCHOR; MIN. 3 PER JAMB
NOTE:
REFER TO DRAWINGS AND
SPECIFICATIONS FOR DOOR
AND FRAME HARDWARE
INTERSECTING WALL LINE
WHERE OCCURS
HOLLOW METAL
DOOR FRAME
SCHEDULED PARTITION
INSULATION
DOOR LEAF CLOSER
REINFORCER
STEEL STIFFENERS
MIN.
2"
HOLLOW METAL
DOOR FRAME
SCHEDULED PARTITION
INSULATION
STEEL STIFFENERS
MIN.
2"
DOOR LEAF STEEL
HINGE
REINFORCEMENT
DOOR FRAME
STEEL HINGE
REINFORCEMENT
SCALE
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #
THIS DRAWING IS AN INSTRUMENT OF
SERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NO
PART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN
ANY FORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT.
M
A R
IE
T
T A
S T
R E
E T
N
W U
N
IT
A
T L A
N T
A
G E
O R
G
IA
T
F w w w .s iz e m o re g ro u p
.c o m
S
IZ
E
M O
R E
G R
O U
P
12/12/25
As indicated
2/25/2026 4:28:35 PMAutodesk Docs://24260FLOLEC_Floyd_County_Law_Enforcement_Center/24260SLOYLEC_Floyd_County_LEC.rvt
A600
DOOR
SCHEDULE AND
DETAILS
Checker
Author
12/12/25
24260FLOLEC
F L O
Y D
C O
U N
T Y
L E
C R
E N
O V
A T
IO
N
G
O V
E R
N M
E N
T P
L A
Z A
R O
M E
G
A
100% CONSTRUCTION DOCUMENTS
DOOR SCHEDULE
DOOR # LOCATION LEAF #
DOOR FRAME FIRE
RATING
HARDWARE
DOOR COMMENTSTYPE WIDTH HEIGHT THICKNESS MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL SET TYPE PANIC CARD READER
101 VESTIBULE DBL F 6'-0" 7'-0" 2" F-1 -- A1 YES No EXIT ONLY DOOR
103 ELEVATOR EQUIPMENT SGL B 3'-0" 7'-0" 1 3/4" HM PAINT 1 WD HM 1/A600 2/A600 90 MIN 2 NO No
202 LOBBY SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 3 NO No
203 JANITOR SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 4 NO No
205 SHERIFF BULLPEN SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 5 NO No
206 SHERIFF SUPERVISOR SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 1 NO Yes SECURITY NOTES: M, EL
251A CORRIDOR SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 6 YES Yes SECURITY NOTES: M, EL, DE
251B CORRIDOR DBL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 WD HM 1/A600 2/A600 -- 7 YES Yes SECURITY NOTES: M, EL
254A HOLDING SGL D 3'-0" 7'-0" 2" HM PAINT 2 HM HM 5/A600 6/A600 -- 8 NO No
254B HOLDING SGL D 3'-0" 7'-0" 2" HM PAINT 2 HM HM 5/A600 6/A600 -- 8 NO No
256A SHERIFF OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 1 NO Yes SECURITY NOTES: M, EL
256B SHERIFF OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 WD HM 1/A600 2/A600 45 9 NO Yes SECURITY NOTES: M, EL
257 LOBBY SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 10 YES Yes SECURITY NOTES: M, EL
259A COURTROOM SEATING DBL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 45 MIN 11 YES No
259B COURTROOM SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 12 YES Yes SECURITY NOTES: M, DE
259C CORRIDOR SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 WD HM 1/A600 2/A600 45 13 YES Yes SECURITY NOTES: M, EL
262 ATTORNEY MTG SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 14 NO No
265 ATTORNEY MTG SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 WD HM 1/A600 2/A600 45 15 NO No
270 LOBBY SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 16 NO No
301 SUPPLY SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 6 YES Yes SECURITY NOTES: DE, EL, M
302 LOBBY SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 3 NO No
303 JANITOR SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 4 NO No
352 CORRIDOR SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 17 YES No
353 OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 5 NO No
354 OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 5 NO No
355 OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 5 NO No
356 OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 5 NO No
363 OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 5 NO No
365 LOBBY SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 16 NO No
367A LOBBY SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 10 YES Yes SECURITY NOTES: M, EL
367B WORKSPACE / COUNTER SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 6 NO Yes SECURITY NOTES: M, EL
368 OFFICE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 1 Yes
373A SUPPLY/STORAGE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 1 Yes SECURITY NOTES: M, EL
373B SUPPLY/STORAGE SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 1 Yes SECURITY NOTES: M, EL
374 FILE/VAULT SGL B 3'-0" 7'-0" 1 3/4" WD PAINT 1 HM HM 1/A600 2/A600 - 4 Yes SECURITY NOTES: M, EL
E101 LOBBY DBL EX 5'-10" 8'-0 1/4" 2" EX EA1 YES Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, DE
E104 LOBBY EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E1 YES Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, DE
E204 STAIR EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E2 YES Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, EL
E205 SHERIFF BULLPEN EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E3 NO Yes EXISTING TO REMAIN | SECURITY NOTES: M, EL
E232 BREAK ROOM EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E3 NO Yes EXISTING TO REMAIN | SECURITY NOTES: M, EL
E233 STAIR EX EX 4'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> 45 E4 YES Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, EL
E257 CORRIDOR EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E5 YES Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, EL
E258 COPY/PRINT/DOCUMENT ASSEMBLY EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E261 CORRIDOR EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E5 YES Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, EL
E263 ATTORNEY MTG. EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E264 EQUIPMENT STORAGE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E265 ATTORNEY MTG EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E3 NO Yes EXISTING TO REMAIN | SECURITY NOTES: M, EL
E267 CORRIDOR EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E5 YES Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, EL
E271 PROBATION EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E272 PROBATION EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E273 STORAGE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E274 PROBATION EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E275 OFFICE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E276 CLERK EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E277 DEP. CLERK EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E278 DEP. CLERK EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E279 DEP. CLERK EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E280 OFFICE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E281 PUBLIC DEF. EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E282 STORAGE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - NO No EXISTING TO REMAIN
E304 STAIRS EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E2 Yes EXISTING TO REMAIN - NEW PANIC HARDWARE TO BE
INSTALLED | SECURITY NOTES: M, EL
E306 WORKSPACE/COUNTER EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - No EXISTING TO REMAIN
E326 STAIRS EX EX 4'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> 45 E4 YES Yes EXISTING TO REMAIN | SECURITY NOTES: M, EL
E360 OFFICE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - No EXISTING TO REMAIN
E361 OFFICE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - No EXISTING TO REMAIN
E362 OFFICE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E3 No EXISTING TO REMAIN | SECURITY NOTES: M, EL
E373C SUPPLY/STORAGE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - No EXISTING TO REMAIN
E375 CORRIDOR EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E3 No EXISTING TO REMAIN | SECURITY NOTES: M, EL
E376 STORAGE EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - No EXISTING TO REMAIN
E377 SUPPLY EX EX 3'-0" 7'-0" 1 3/4" WD <By Category> EX EX <By Category> - E3 Yes EXISTING TO REMAIN | SECURITY NOTES: M, EL
3" = 1'-0"A600
3 TYP. CMU HM DOOR HEAD
3" = 1'-0"A600
4 TYP. CMU HM DOOR JAMB
3" = 1'-0"A600
1 TYP. HM DOOR HEAD
3" = 1'-0"A600
2 TYP. HM DOOR JAMB
N o
D
E S
C R
IP
T
IO
N
D A
T E
P
R E
-B
ID
A D
D E
N D
U M
/1
/2
P
R E
-B
ID
A D
D E
N D
U M
/2
/2
3" = 1'-0"A600
5 CMU HM DET. DOOR HEAD
3" = 1'-0"A600
6 CMU HM DET. DOOR JAMB
1 1
| ADDENDUM #3_WordOnly.pdf |
| 24260FLOLEC_Floyd_County_LEC - A600 DOOR SCHEDULE & DETAILS PreBid Addendum #3 |
| Sheets |
| A600 - DOOR SCHEDULE AND DETAILS |
File details come from the government source that posted it. Updated .