Addendum #3 2026-057M23 Cameras Building analysis.pdf
PDF 24 KB Posted
- Solicitation number
- RFP IHHA 2027000024 5
- Issued by
- Pueblo County, Colorado
About this file
This is Addendum #3 to Contract 2026-057M23, a camera infrastructure installation project for Colorado state and local agencies including Colorado Mental Health Institute at Pueblo (CMHHIP) and Spring Creek Youth Services in Colorado Springs. The project involves comprehensive interior and exterior camera system analysis across multiple buildings, with specific focus on IP camera installation and supporting infrastructure. The scope encompasses 29 buildings or building areas with varying risk classifications (Low, Intermediate, and High Risk/Security) and occupancy types including healthcare patient-occupied spaces, business areas, and vacant facilities. Building construction dates range from 1939 to 2009, with most utilizing masonry or metal stud/drywall construction. The project identifies current camera locations, server rooms, emergency nursing stations, and tunnel access points, noting that certain areas such as Spring Creek Youth Services and Building 117 North Kitchen have been descoped or will be incorporated into separate projects.
The analysis indicates that most buildings have dedicated UPS (uninterruptible power supply) systems and emergency generator access, with electricity and dedicated infrastructure already available at identified server room locations. Multiple buildings, particularly the 2009 construction buildings (Building 140, Areas A through L), are classified as High Risk/Security healthcare patient-occupied spaces requiring comprehensive camera coverage connected to master server rooms. Building 129 (Buildings A & B) completed in 2006 and Building 137 are designated as Medium and Low Risk facilities respectively. The infrastructure requirements include both interior and exterior camera placement with existing emergency nursing station cabinets and server room infrastructure serving as primary connection points throughout the campus facilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Cams - PreSubmittal Mtg Sign In sheet.pdf | ||
| Certificate.pdf | ||
| Appx B - SC-9.1 DBGMP GC 2022 09 clean.docx | DOCX document | |
| Addendum #3 pics.pdf | ||
| CDHSCP_Solicitation_Request_Documents_-_7-29-2026_-_66330298_-__-_0.00 (7).docx | DOCX document | |
| Information for bidders.pdf | ||
| Addendum 2 .docx | DOCX document | |
| Addendum #3 Question and Answers.pdf | ||
| DIRECTIONS To CMHIP bldg 49 w Detour.pdf | ||
| Appendix F.pdf | ||
| 2024-057M23 CMHHIP Camera Project-RFP clean (1).docx | DOCX document | |
| DFM Contractor Security Clearance Form 10_16_2025.xlsx | XLSX spreadsheet | |
| Addendum #3 Camera Proj Appx cable length with notes (1).pdf | ||
| Addendum 1 Mandatory Walkthrough Information.docx | DOCX document | |
| Appx B - SC-9.0 DB GMP A_2025 clean.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Interior Exterior
Descoped Spring Creek Youth Services, Colorado Springs - Completed in previous project
49 Maint Staff 1930 Masonry Mtl Stud / DW No none Server Cubby Monitoring only Low Risk / Security Business Business Occupied
106 1st Floor 1949 Masonry Mtl Stud / DW Yes Yes, Em Nrs St / Tunnel Interior & Exterior Intermediate Risk / Security Healthcare Patient Occupied
106 2nd Floor 1950 Masonry Mtl Stud / DW No Yes, Em Nrs St / Tunnel Interior Intermediate Risk / Security Healthcare Patient Occupied
106 3rd Floor 1951 Masonry Mtl Stud / DW No Yes, Em Nrs St / Tunnel Interior Business / Admin Business Business Occupied
115 1st Floor 1939 Masonry Masonry Yes Yes, Em Nrs Stn cab't / 1st flr Interior & Exterior Low Risk / Security Healthcare Vacant
115 2nd Floor 1939 Masonry Masonry No Yes, Em Nrs Stn cab't / 1st flr Interior Low Risk / Security Healthcare Vacant
115 Tunnel unk Concrete N/A -- Yes, Em Nrs Stn cab't / 1st flr None Low Risk / Security Tunnel Vacant
116 1st Floor 1939 Masonry Masonry Yes Yes, Em Nrs Stn cab't / 1st flr Interior & Exterior Medium Risk / Security Healthcare Patient Occupied
116 2nd Floor 1939 Masonry Masonry No Yes, Em Nrs Stn cab't / 1st flr Interior Intermediate Risk / Security Healthcare Patient Occupied
116 Tunnel unk Concrete N/A -- Yes, Em Nrs Stn cab't / 1st flr None Low Risk / Security Tunnel Vacant
Descoped 117 North Kitchen 1939 Masonry Masonry Yes Yes Server Room Interior To be incorporated into New Kitchen project
120 1st Floor 1951 Masonry Masonry Yes Yes, Em none Interior Low Risk / Security Healthcare Business Occupied
121 1st Floor 1952 Masonry Masonry Yes Yes, Em Nrs Stn cab't / 1st flr Interior Low Risk / Security Healthcare Patient Occupied
121 2nd Floor 1952 Masonry Masonry No Yes, Em Nrs Stn cab't / 1st flr Interior Low Risk / Security Healthcare Patient Occupied
121 3rd Floor 1952 Masonry Masonry No Yes, Em Nrs Stn cab't / 1st flr Interior Low Risk / Security Business Business Occupied
121 4th Floor 1952 Masonry Masonry No Yes, Em none Interior Low Risk / Security Business Business Occupied
121 5th Floor 1952 Masonry Masonry No Yes, Em none Interior Low Risk / Security Business Business Occupied
121 6th Floor 1952 Masonry Masonry No Yes, Em none Interior Low Risk / Security Residential Board Vacant
125 1st & 2nd Floors 1964 Masonry Mtl Stud / DW Yes Yes, Em Server Room Bsmt Interior & Exterior Low Risk / Security Business Business Occupied
129 Bldgs A & B 2006 Masonry Mtl Stud / DW No Yes, Em Srvr Rm / Elect Rm Interior & Exterior Medium Risk / Security Healthcare Patient Occupied
130 Rec Center 1965 Masonry Mtl Stud / DW Yes Yes, Em Srvr Rm / Mech Rm Interior & Exterior Low Risk / Security Gym / Library Business Occupied
137 1982 Masonry Mtl Stud / DW No Yes, Em Nurse Station Interior & Exterior Low Risk / Security Healthcare Patient Occupied
140 Area A 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Srvr Rm & Control High Risk / Security Healthcare Patient Occupied
140 Areas B1 / B2 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas C1 / C2 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas D1 / D2 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas E1 / E2 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas F1 / F2 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas G (Corridor) 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Area H 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas J1 / J2 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas K (Corridor) 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
140 Areas L1 / L2 2009 Masonry Mtl Stud / DW Yes Yes, Em Mstr Server Rm Interior High Risk / Security Healthcare Patient Occupied
ProgramElectricity CamerasBldg Construction
Tunnel
Access Generator
Dedicated
UPS
Current Camera
Server Location
Location
Bldg # Location Year Built Shell Interior Walls
New Camera locations Security Level Occupancy Type Current Use
Est. Current # of Cameras
File details come from the government source that posted it. Updated .