Addendum #2 Revised Electrical drawings- Part 1.pdf
PDF 14 MB Posted
- Attached to
- RFP NORTH CAMPUS BID PKG #2
- Solicitation number
- RFP JCI 260000001841 6
- Issued by
- Kalamazoo County, Michigan
About this file
This Addendum #2 document provides revised electrical drawings and specifications for the Torrant Center Additions & Renovations project in Michigan, detailing comprehensive demolition and new construction requirements for Division 26 (electrical) contractor work. The document establishes critical procedural requirements including that all contractors must visit the project site to determine exact demolition scope before bidding, all wall and floor penetrations must be sealed to maintain original fire ratings, and conduits must be field-routed along existing piping and structural steel. The specifications outline extensive demolition work including removal of obsolete exposed conduit, wire, and unused equipment, with surface patching required to match adjacent areas, while existing concealed work that does not interfere with new work may remain in place with proper capping and patching. The addendum includes detailed electrical symbols, abbreviations, and legends; a comprehensive lighting fixture schedule specifying LED equipment from manufacturers including Lithonia, Finelite, and McGraw-Edison with lumen outputs ranging from 1,000 to 7,260 lumens and various configurations (recessed, surface-mounted, wall-pack, and emergency units); and site plans and floor plans across multiple areas (designated A through M) showing demolition and new power, lighting, and mechanical requirements with specific circuit designations, equipment specifications, and installation details.
The document mandates that Division 26 contractors field-verify all equipment voltages and loads prior to service installation and report any discrepancies between drawings and existing conditions to the engineer for clarification. Alternate lighting fixture manufacturers are permitted only if they demonstrate similar performance, physical appearance, and construction, with pre-approval required during the bidding period through submission of cut sheets to the engineer at least one week prior to bid submission, though alternate fixtures for Type "D" wall packs are not allowed. Critical specifications include provisions for GFI-protected devices in designated spaces, recessed floor boxes constructed to Wiremold specifications with vapor barriers, pass-through conduit systems sized at 1-inch, 2-inch, and 4-inch EMT with pull strings, and coordination requirements with owner-provided equipment and furniture suppliers. The contractor is responsible for all patching of existing walls to match adjacent surfaces, asbestos handling under separate owner contract, and coordination of fire alarm delegated design to be provided by Midwest, with equipment specifications including variable frequency drives, transient voltage surge suppression, nurse call systems, CCTV security systems, and occupancy sensor controls integrated throughout the facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. ALL WALL AND FLOOR PENETRATIONS ARE TO BE SEALED TO MAINTAIN ORIGINAL
RATING.
2. ALL CONDUITS TO BE FIELD ROUTED ALONG EXISTING PIPING AND STRUCTURAL
STEEL.
3. THE DIVISION 26 CONTRACTORS SHALL VISIT THE PROJECT AND DETERMINE THE
EXACT EXTENT OF THE DEMOLITION WORK REQUIRED BEFORE BIDDING THE PROJECT.
4. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE AND UNUSED EQUIPMENT
WHERE WORK IS BEING DONE EXCEPT ITEMS NOTED OTHERWISE.
5. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF OLD WORK,
SURFACES SHALL BE PATCHED TO MATCH ADJACENT.
6. EXISTING WORK WHICH IS PRESENTLY CONCEALED AND WHICH WILL REMAIN
CONCEALED AND DOES NOT INTERFERE WITH ANY NEW WORK OF ANY TRADE NEED
NOT BE REMOVED. HOWEVER, ALL CONDUIT SHALL BE CAPPED BELOW FINISH
SURFACE AND THEN PATCHED TO MATCH, OR AS NOTED.
7. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE MODIFIED OR ENLARGED
TO SUIT THE NEW SYSTEMS AS REQUIRED. PROVIDE ALL REQUIRED CUTTING AND
PATCHING.
8. IF ASBESTOS IS PRESENT, IT WILL BE REMOVED OR RENDERED HARMLESS UNDER
SEPARATE CONTRACT BY THE OWNER.
9. THE DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING
WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL SURFACE MOUNTED
EQUIPMENT.
10. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT VOLTAGES AND LOADS PRIOR TO
INSTALLING SERVICE TO EQUIPMENT.
11. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENT AND CASUAL FIELD
OBSERVATION. REPORT ANY DISCREPANCIES TO ENGINEER FOR CLARIFICATION.
12. DELEGATED FIRE ALARM DESIGN TO BE PROVIDED BY MIDWEST.
GENERAL ELECTRICAL NOTES
FCPS
V
M C
VI
AV
B
C
DC
M
B
KP
SSCP
CR
SS
AS
TS
G
NCC
M P
E
A L B1 B2
S
SRS
X
X
X
CB
EMERGENCY PUSH STATION
CODE BLUE STATION
TVSS
VFD
TRANSIENT VOLTAGE SURGE SUPPRESSION
VARIABLE FREQUENCY DRIVE
GLASS BREAK
DS
DUPLEX RECEPTACLE
TEACHER STATION
ADMINISTRATION STATION
STUDENT STATION
CARD READER
CARBON MONOXIDE DETECTOR
H
DOCK LIGHT FIXTURE
CONTROL MODULE
S
TELEPHONE / DATA OUTLET
DUTY STATION
STAFF STATION
STAFF REGISTER STATION
DOME LIGHT
DUAL BED STATION
SINGLE BED STATION
BED / LIGHT INTERFACE
PENDENT INTERFACE
EMERGENCY PULL STATION
MASTER STATION
NURSE CALL CONTROLLER
NURSE CALL
ADDENDUM NOTE
PLAN NOTE
DEMOLITION NOTE
THREE PHASE MOTOR
BELL
AUDIO / VIDEO INPUT
VIDEO INPUT
WALL MOUNTED SPEAKER / CLOCK COMBO
WALL MOUNTED SPEAKERS
DUAL FACE CLOCK
CCTV CONTROL PANELCCTV
SECURITY SYSTEM CONTROL PANEL
KEY PAD
BEAM DETECTOR
MOTION DETECTOR
DOOR CONTACT
CAMERA
MONITOR MODULE
FIRE CONTROL POWER SUPPLY
VISUAL ONLY UNIT
ELECTRICAL SYMBOLS LEGEND
DH
V
S
C
M
I
J
SINGLE RECEPTACLE (120 VOLT)
EMERGENCY RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
SINGLE FACE CLOCK
FLUSH FLOOR BOX
SURFACE FLOOR BOX
SPECIAL EQUIPMENT RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET
POWER POLE
JUNCTION BOX
WALL JUNCTION BOX
PULL (JUNCTION) BOX
UNDERFLOOR JUNCTION BOX
OUTLETS
LIGHT FIXTURE
STRIP FIXTURE
IN-GRADE LIGHT FIXTURE
SPOTLIGHT (number of heads shown) EXIT SIGN (face & direction as shown)
WALL MOUNT LIGHT FIXTURE
CEILING LIGHT FIXTURE
TRACK & FIXTURE
STREET TYPE POLE FIXTURE
POLE MOUNTED LIGHT FIXTURE
EXTERIOR WALL MOUNT LIGHT FIXTURE
WALLPACK LIGHT FIXTURE
SPECIAL PURPOSE LIGHT FIXTURE
HIGH BAY LIGHT FIXTURE
EMERGENCY EGRESS LIGHT FIXTURE
(number of heads shown)
EMERGENCY LIGHT FIXTURE
FIXTURES
SWITCHES
SINGLE-POLE SWITCH
DIMMER SWITCH
TIME SWITCH
KEY SWITCH
MANUAL MOTOR SWITCH
THERMAL OVERLOAD SWITCH
SWITCH WITH PILOT LIGHT
FOUR-WAY SWITCH
THREE-WAY SWITCH
CIRCUITRY and RACEWAYS
UNDERFLOOR DUCT
BUS DUCT
PLUGMOLD AS SPECIFIED
WIREMOLD AS SPECIFIED
FLEXIBLE PIGTAILS/CONNECTIONS
"CONDUIT RUN CONTINUES" INDICATION
END OF CONDUIT RUN, CAP AND STAKE
END OF CONDUIT RUN
HOME RUN (with circuit numbers)
CONDUIT STUB DOWN
CONDUIT STUB UP
CONDUIT INSTALLED
CONDUIT INSTALLED
MECHANICAL
ELECTRIC WATER HEATER
ELECTRIC UNIT HEATER
PIPE TRACE HEATER
RESISTANCE HEATER, KW SHOWN
SINGLE PHASE MOTOR
SOUND and SIGNAL
INTERCOM OUTLET
MICROPHONE OUTLET
TELEVISION OUTLET
CHIME
BUZZER
VOLUME CONTROL
SPEAKER
SERVICE and EQUIPMENT
THERMOSTAT
CAPACITOR
ENCLOSED CIRCUIT BREAKER
TRANSFER SWITCH
WIREWAY
GROUND CONNECTION PER N.E.C.
TELEPHONE TERMINAL BOARD
GENERATOR, KW SHOWN
CURRENT TRANSFORMERS
UTILITY METER, AS REQUIRED
WEATHERHEAD
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
COMB. STARTER
MAGNETIC STARTER
FUSED DISCONNECT SWITCH
TRANSFORMER
CONTROL
xxVA connection by x/C) IRRIGATION CONTROLLER (120 volt
LIGHTING CONTACTOR
CONTROL TRANSFORMER
buttons indicated) PUSHBUTTON STATION (number of TIME CLOCK (24 hour U.O.N.)
PHOTOCELL (voltage as required)
HUMIDISTAT
FIRE ALARM
TAMPER SWITCH (furnished by FP/C) FLOW SWITCH (furnished by FP/C)
FIREFIGHTER COMMUNICATION JACK
MAGNETIC DOOR HOLDER
REMOTE INDICATING LIGHT, CLG. MTD.
REMOTE INDICATING LIGHT, WALL MTD.
END OF LINE DEVICE
ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
PULL STATION
SPEAKER & LIGHT
SPEAKER
HORN
DUCT SMOKE DETECTOR
HEAT DETECTOR
SMOKE DETECTOR
HORN & LIGHT
DESIGNATIONS
(by E.C.)
(by others)
TT
FACP
ANN
EOL
G
WW
PC
CT
TS
T
H
TC
IC
F
FC
F
T
1,3
OR
PM
WM
BD
UFD
B
F S
J
J
D
WH
PP
J
SWITCH STYLE OCCUPANCY SENSOROC
DIGITAL TIME SWITCH
POWER PACK
DUAL TECHNOLOGY SENSOR - 360° - 500 SQ FT
DUAL TECHNOLOGY SENSOR - 360° - 1000 SQ FT
ULTRASONIC SENSOR - 360° - 2 CIRCUIT
OCCUPANCY SENSOR / PHOTOCELL
WALL MOUNT DUAL TECHNOLOGY SENSOR
OS5
OS4
T
OS2
OS3
OS1
PP
DUCT SMOKE DETECTORF/S
CEILING MOUNTED WIFI
DIGITAL EQUIPMENT METER, AS REQUIRED
POLE
PUMP
PANEL
P
PNL
PVC
PRV-
P-
PB
POLY VINYL CLORIDE
POWER ROOF VENTILATOR
PULL BOX
GENERAL CONTRACTOR
GROUND
HUMIDIFIERH-
GND
GFI
GC
GROUND FAULT INTERRUPTER
ABBREVIATIONS LEGEND
POWER
SWITCH
RECEPT
SF-
SWBD
TCC
SPEC
SW
RGC
RTU-
PWR
VOLTS
WATTS
UF
V
W
UL
VL
UNO
UH-
TS
TYP
TR
ROOF TOP UNIT
RECEPTACLE
SWITCHBOARD
UNDER FLOOR
SPECIFICATIONS
RIGID GALVANIZED STEEL CONDUIT
UNLESS NOTED OTHERWISE
UNDERWRITERS' LABORATORIES, INC.
TAMPER PROOF RECEPTACLE
TAMPER PROOF SWITCH
TEMPERATURE CONTROL CONTRACTOR
VERIFY LOCATION WITH OWNER
TYPICAL
UNIT HEATER
SUPPLY FAN
WITH
WITHOUT
W/
XFMR
W/O
WP
TRANSFORMER
WEATHER PROOF
HOUR
LIGHT
JUNCTION BOX
LIGHT CONTROL
ISOLATED GROUND
HORSEPOWER
MINIMUM
MOUNT
MAKE-UP AIR UNIT
MOTOR CONTROL CENTER
MAIN LUG ONLY
MOUNTED
MOUNTING
MAXIMUM
LIGHTING
LT FLEX
MTD
MUAU-
MTG
MLO
MIN
MT
MC
MAX
MCC
LTG
IG
LC
LT
IMC
JB
HR
HVAC
HOA
HP
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHTNL
NTS
NO
NIC
NC
HAND-OFF-AUTO SELECTOR SWITCH
HEATING/VENTILATING/AIR CONDITIONING
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
MECHANICAL CONTRACTOR
HID HIGH INTENSITY DISCHARGE
A
AC
AFF
ACU-
AHJ
AHU-
AS
B-
BC
AIC
ATS
BLDG
CHLR-
CND (C)
CKT BKR
CKT
CUH-
CU-
DISC
DFU-
EF-
EC
DWH-
EBB-
DWG
CT-
EXIST./EX.
EWC
FLEX
FLA
FLR
FSES
FLUOR
EMT
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AMPS
ABOVE COUNTER
AIR HANDLING UNIT
AUTOMATIC TRANSFER SWITCH
AMPS INTERRUPTING CAPACITY
AUTHORITY HAVING JURISDICTION
ABOVE SHELF
BOILER
BUILDING
BELOW COUNTER
CHILLER
DOMESTIC WATER HEATER
CABINET UNIT HEATER
CIRCUIT
CIRCUIT BREAKER
CONDUIT
CONDENSING UNIT
COOLING TOWER
DUCT FURNACE
DRAWING
DISCONNECT
FOOD SERVICE EQUIP. SUPPLIER
ELECTRIC WATER COOLER
ELECTRICAL CONTRACTOR
ELECTRIC BASEBOARD
ELECTRICAL METALLIC TUBING
EXISTING
EXHAUST FAN
FLOOR
FLUORESCENT
FLEXIBLE CONDUIT
FULL LOAD AMPS
EM EMERGENCY
F/S FIRE/SMOKE
FU- FURNACE
2X4 LED FLAT PANEL.
FIXTURE
MOUNTING
HEIGHT
LIGHT ENGINEDESCRIPTION AND COMMENTSTYPE MANUFACTURER CATALOG NO.
LIGHTING FIXTURE SCHEDULE
C8
LITHONIA CPX-2X4-3000LM-80CRI-SWL-MIN10-ZT-MVOLT
CPX-2X4-3000LM-80CRI-SWL-MIN10-ZT-MVOLT-E10WLITHONIA
3G-DL45RF-10-H95-35K-60D-UNV-DIM-WT-WI-NC3G LIGHTING
3G-DL45RF-10-H95-35K-60D-UNV-DIM-WT-WI-NC-EMB3G LIGHTING
3G LIGHTING
3G LIGHTING
HP-3-R-D-6'-S-835-DSO-120-SC-FC-10%FINELITE
HP-3-R-D-8'-S-835-DSO-120-SC-FC-10%
C8EM
C6
B2EM
B2
B1EM
B1
AEM
A
2X4 LED FLAT PANEL EQUIPPED WITH INTEGRAL 10W BATTERY BACKUP.
4" LED ROUND FIXED DOWNLIGHT.
4" LED ROUND FIXED DOWNLIGHT EQUIPPED WITH 7W INTEGRAL BATTERY BACKUP.
6' LED RECESSED LINEAR WITH 3" APERTURE.
8' LED RECESSED LINEAR WITH 3" APERTURE.
8' LED RECESSED LINEAR WITH 3" APERTURE WITH 10W INTEGRAL BATTERY BACKUP.HP-3-R-D-8'-S-835-DSO-120-SC-FC-10%-LGD10W
RECESSED
3000 LUMENS
24.6W, 3500K
LED
3000 LUMENS
24.6W, 3500K
LED
RECESSED
1000 LUMENS
9.0W, 3500K
LED
DIMMING INFO
0-10V
TO 10%
C8B 8' LED RECESSED LINEAR WITH 3" APERTURE.HP-3-R-D-8'-B-835-DSO-120-SC-FC-10%
C12 12' LED RECESSED LINEAR WITH 3" APERTURE.HP-3-R-D-12'-B-835-DSO-120-SC-FC-10%
D LED WALL PACK WITH TYPE IV WIDE OPTICS AND BRONZE FINISH.MCGRAW-EDISON GWC-SA1-A-740-U-T4W-BZ-BPC
4900 LUMENS
34.0W, 4000K
LED
8' ABOVE GRADE
XA SINGLE FACE EXIT SIGN WITH BRUSHED ALUMINUM FACE AND RED LETTERS.LITHONIA LQC-1-R-EL N LED-
0-10V
TO 10%
0-10V
4" LED ROUND FIXED DOWNLIGHT.
4" LED ROUND FIXED DOWNLIGHT EQUIPPED WITH 7W INTEGRAL BATTERY BACKUP.
3G-DL45RF-15-H95-35K-60D-UNV-DIM-WT-WI-NC-EMB
3G-DL45RF-15-H95-35K-60D-UNV-DIM-WT-WI-NC-EMB
FINELITE
FINELITE
FINELITE
FINELITE
0-10V
TO 10%
0-10V
TO 10%
0-10V
TO 10%
0-10V
TO 10%
0-10V
TO 10%
0-10V
TO 10%
0-10V
TO 10%
0-10V
TO 10%
0-10V
TO 10%
RECESSED
RECESSED
RECESSED
RECESSED
RECESSED
RECESSED
RECESSED
RECESSED
RECESSED
1000 LUMENS
9.0W, 3500K
LED
1500 LUMENS
13.7W, 3500K
LED
1500 LUMENS
13.7W, 3500K
LED
3630 LUMENS
40.2W, 3500K
LED
4840 LUMENS
53.6W, 3500K
LED
4840 LUMENS
53.6W, 3500K
LED
6056 LUMENS
58.4W, 3500K
LED
7260 LUMENS
80.4W, 3500K
LED
XB LITHONIA AFF-OEL-DBLBXD-UVOLT-LTP-SDRT-WT-CW ARCHITECTURAL EMERGENCY LIGHT WITH COLD WEATHER RESISTANCE. -- LED
M
DIMMABLE SWITCH STYLE OCCUPANCY SENSOROCD
HP-3-R-D-6'-S-835-DSO-120-SC-FC-10%-LGD10WFINELITEC6EM 6' LED RECESSED LINEAR WITH 3" APERTURE WITH 10W INTEGRAL BATTERY BACKUP. 0-10V
TO 10% RECESSED
3630 LUMENS
40.2W, 3500K
LED
C12EM 12' LED RECESSED LINEAR WITH 3" APERTURE WITH 10W INTEGRAL BATTERY BACKUP.HP-3-R-D-12'-B-835-DSO-120-SC-FC-10%-LGD10WFINELITE 0-10V
TO 10% RECESSED
7260 LUMENS
80.4W, 3500K
LED
DEM LED WALL PACK WITH TYPE IV WIDE OPTICS AND BRONZE FINISH.MCGRAW-EDISON 8' ABOVE GRADE0-10VGWC-SA1-A-740-U-T4W-BZ-CBP-BPC
4900 LUMENS
34.0W, 4000K
LED
CLX-L48-4000LM-SEF-WDL-MVOLT-GZ1-40K-80CRI-WHLITHONIAE 4' LED STRIP FIXTURE.
4000 LUMENS
38W, 3500K
LED
SUSPENDED0-10V1. ALTERNATE LIGHTING MANUFACTURERS EQUIPMENT SHALL BE SIMILAR IN
PERFORMANCE, PHYSICAL APPEARANCE, AND CONSTRUCTION SHALL BE
CONSIDERED AS EQUAL TO FIXTURES SPECIFIED.
2. ALTERNATE FIXTURES PROPOSED BY BIDDING CONTRACTOR MUST BE
PRE-APPROVED DURING BIDDING. CONTRACTOR OR LIGHTING REPRESENTATIVE
SHALL EMAIL ALL FIXTURE CUT SHEETS TO ENGINEER AT LEAST 1 WEEK PRIOR TO
SUBMITTING BIDS. ENGINEER SHALL REVIEW THE PROPOSED FIXTURES AND ISSUE AN
ACCEPTANCE OR DENIAL. SHOP DRAWINGS SUBMITTED AFTER AWARD FOR FIXTURES
WHICH WERE NOT PRE-APPROVED ARE SUBJECT TO BEING REJECTED. ENGINEER
SHALL HAVE FINAL AUTHORITY ON APPROVAL OF THE PROPOSED ALTERNATIVE
FIXTURES. ALTERNATE SUBMISSION SHALL DEMONSTRATE A SAVINGS TO THE OWNER
OR INCREASE IN QUALITY TO BE REVIEWED.
3. ALTERNATE FIXTURES FOR TYPE "D" ARE NOT ALLOWED.
FIXTURE SCHEDULE NOTES
1X4 LED FLAT PANEL WITH SURFACE MOUNT KIT.LITHONIA CPX-1X4-2000LM-80CRI-SWL-MIN10-ZT-MVOLT; 1X4SMKSHF SURFACE
2000 LUMENS
17.2W, 3500K
LED
0-10V
TO 10%
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E1
E L E C
T R
IC
A L S
Y M
B O
L S
N
O T E S
A B
B R
E V
A N
D S
C H
E D
U L E S
AC
AC
AC
AC
AC
AC
AC
STOP
VAN
STOP
VAN
S T
O P
V A
N
1 1 1
EXISTING PNL "C"
EXISTING PNL "C2"
EXISTING PNL "D"
EXISTING PNL "D2"
EXISTING LIGHT FIXTURE TO REMAIN.
EXISTING LIGHT FIXTURE, POLE, AND BASE TO REMAIN.
DISCONNECT & REMOVE EXISTING LIGHT FIXTURE AND POLE. ASSOCIATED
POLE BASE, CONDUIT, AND WIRE TO REMAIN.
DISCONNECT & REMOVE EXISTING LIGHT FIXTURE, POLE, AND BASE.
REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO NEW HANDHOLE.
CONDUIT AND WIRE SHALL BE EXTENDED TO NEAREST ADJACENT POLE IN
NEW LAYOUT.
DISCONNECT & REMOVE EXISTING LIGHT FIXTURE, POLE, AND BASE.
REMOVE ASSOCIATED WIRE BACK TO SOURCE. REMOVE ASSOCIATED
CONDUIT TO 18" BELOW GRADE, AND ABANDON IN PLACE.
DEMOLITION NOTES
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
N ELECTRICAL SITE PLAN - DEMOLITION
SCALE: 1" = 50'-0"
1050 20 40 80 125
E2
E L E C
T R
IC
A L
S
IT
E P
L A N
D E M
O L
IT
IO
N
ELECTRICAL KEY NOTES
CONTRACTOR SHALL REUSE EXISTING POLE BASE FOR NEW POLE.
CONTRACTOR SHALL VERIFY EXISTING BOLT PATTERN, PRIOR TO ORDERING
POLES. CONTRACTOR SHALL REUSE EXISTING CONDUIT AND WIRE FOR NEW
FIXTURE.
CONTRACTOR SHALL PROVIDE AND INSTALL NEW POLE BASE AT NEW
LOCATION. CONTRACTOR SHALL PROVIDE AND INSTALL NEW CONDUIT AND
WIRE FOR NEW FIXTURE. EXTEND EXISTING CIRCUIT FROM NEAREST
ADJACENT FIXTURE.
CONTRACTOR SHALL PROVIDE AND INSTALL NEW EAGLE MOUNTAIN
NIGHTMASTER FLAGPOLE, WITH INTEGRATED LIGHT AT TOP. COORDINATE
WIRING REQUIREMENTS WITH MANUFACTURER RECOMMENDATIONS. LIGHT
SHALL BE CONTROLLED BY NEW PHOTOCELL, WITH LOCAL OVERRIDE
SWITCH LOCATED IN BUILDING. COORDINATE SWITCH LOCATION AND POLE
HEIGHT WITH OWNER.
CONTRACTOR SHALL PROVIDE AND INSTALL NEW 13"x24"x12" OPEN BOTTOM
HANDHOLE QUAZITE #PC1324BA12 WITH DIVIDER. CONTRACTOR SHALL
PROVIDE AND INSTALL REQUIRED BOX EXTENSIONS TO ACHIEVE PROPER
CONDUIT DEPTH. PROVIDE "ELECTRIC" COVER #PC1324CA0017. REFER TO
DETAIL FOR MORE INFORMATION.
COMMUNICATIONS HANDHOLE, AS SPECIFIED IN DETAIL.
ELECTRICAL HANDHOLE, AS SPECIFIED IN DETAIL.
CONTRACTOR SHALL PROVIDE AND INSTALL (1) 1-1/2" CONDUIT FOR
EXTERIOR SIGN POWER. CONTRACTOR SHALL PROVIDE AND INSTALL NEW
13"X24"X12" OPEN BOTTOM HANDHOLE QUAZITE #PC1324BA12 WITH DIVIDER.
CONTRACTOR SHALL PROVIDE AND INSTALL REQUIRED BOX EXTENSIONS
TO ACHIEVE PROPER CONDUIT DEPTH. PROVIDE "ELECTRIC" COVER
#PC1324CA0017. REFER TO DETAIL FOR MORE INFORMATION.
ALL NEW POWER AND DATA PATHWAYS SHALL BE ROUTED THROUGH THIS
ADDITION, FOR CONNECTION TO ASSOCIATED PANEL AND DATA
TERMINATION LOCATIONS.
1. ALL FIXTURES, NEW AND EXISTING, SHALL BE CONTROLLED BY NEW TIMECLOCK.
FIXTURES SHALL HAVE INTEGRAL PHOTOCELL, TO BE UTILIZED FOR CONTROLS, WITH
TIMECLOCK FOR SCHEDULED ON/OFF.
2. THE EXISTING FIELD CONDITIONS AND WIRING IS NOT KNOWN, CONTRACTOR SHALL
FIELD VERIFY AS NEEDED.
GENERAL ELECTRICAL NOTES
UNDERGROUND RACEWAY LEGEND
UNDERGROUND ELECTRICAL RACEWAY: CONDUIT SHALL BE ROUTED BACK
TO PANEL.
UNDERGROUND COMMUNICATIONS RACEWAY: CONDUIT SHALL BE ROUTED
BACK TO I.T. RACK.
AC
AC
AC
AC
AC
11 9
B U
S E
S O
N
LY
14141414
2151515
BUSES
ONLY
STOP
VAN
STOP
VAN
S T
O P
V A
N
HH
T5W
T5W
T5W T5W
T5W T5W
T5W T5W
T5W T5W 2 2
T2
T2
T2
T5W
T5W
T2
T5W
EX
EX
T4W
EX
EX
2T4FT
T4FT
T4FT
T4FT
T4FT
T4FT
T2-HSS
T2-HSS
T2-HSS
T2-HSS
T2-HSS
T2
T4W
T4W
SL2 2
SL2
SL2
SL2 2
SL22
SL2
SL2
SL2
SL2
SL2
SL2
6 (TYP.)
(TYP.)
7HH
7HH
J
(2) #6
(1) #10 GND
1" CND
(3) #10
(1) #10 GND
1" CND
(3) #4
(1) #10 GND
1" CND
(3) #6
(1) #10 GND
1" CND
(3) #8
(1) #10 GND
1" CND
(3) #8
(1) #10 GND
1" CND
(3) #6
(1) #10 GND
1" CND
R-13
R-38,40 R-42,44
R-39,41
R-43,44
R-47,49
EXISTING PNL "C"
EXISTING PNL "C2"
EXISTING PNL "D"
EXISTING PNL "D2"
EX EX EX
EX
(2) #4
(1) #10 GND
1" CND
D2-2
C2-3
D2-4
D2-5,6
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
N ELECTRICAL SITE PLAN - NEW
SCALE: 1" = 50'-0"
1050 20 40 80 125
E3
E L E C
T R
IC
A L
S
IT
E P
L A N
N
W
DISCONNECT & REMOVE EXISTING SURFACE TELEPHONE CABLE, MASTS,
AND SLEEVES. COORDINATE TELEPHONE REMOVAL WITH OWNER.
DEMOLITION NOTES1
A E6
A E7
B E8
B E9
C E10
D E11
E E12
F E13
G E14
H E15
I E16
J E17K
E18
L E19
M E20
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
N COMPOSITE ELECTRICAL FLOOR PLAN - DEMOLITION
E5
C O
M P O
S
IT
E E L E C
T R
IC
A L F
L O
O R
P L A N
D
E M
O L
IT
IO
N
SCALE: 1/32" = 1'-0"
0 51 10 25 80
EX Q
EX R
F
F
F
GFI
GFI
GFI
J
J
J
J
J
J J
J
WP
J
J
S S
F C
C
C
C
WEATHERHEAD
(ON ROOF)
J
J
J
72"
AFF
J
J
C
C
C
C
C
C
EWC
3 3
3 3 3
C J J
J
S
BC
GFI
AC
GFI
C
J
C
FJ
J
S
J
EXIST. PNL
"P"
CU
CU
EXISTING DEVICE TO REMAIN.
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL DEVICES IN THIS
SPACE, UNLESS NOTED OTHERWISE. REMOVE CONDUIT AND WIRE BACK TO
SOURCE.
DISCONNECT AND REMOVE EXISTING PANEL. REFER TO SHEET E-900 FOR
RELOCATED BRANCH CIRCUITS. EXTEND CONDUIT AND WIRE AS NEEDED TO
NEW PANEL SPECIFIED.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
CAP AND REMOVE ABANDONED ELECTRICAL CONDUIT AND WIRE IN THIS
LOCATION.
DISCONNECT AND REMOVE EXISTING DEVICE FOR CEILING MODIFICATIONS.
REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "A"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E7
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A A
N KEY PLAN
NOT TO SCALE
3 3
11111 11
1 1
TC
55555
EXISTING LIGHT FIXTURE TO REMAIN.
EXISTING DEVICE TO REMAIN.
DISCONNECT AND REMOVE ALL EXISTING LIGHT FIXTURES IN THIS SPACE,
UNLESS NOTED OTHERWISE. REMOVE CONDUIT AND WIRE BACK TO
SOURCE.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES AND DEVICES FOR
CEILING MODIFICATIONS. REMOVE CONDUIT AND WIRE BACK TO NEAREST
JUNCTION BOX.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - LIGHTING DEMOLITION - AREA "B"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E8
P A R
T
IA
L F
L O
O R
P L A N
L
IG
H
T
IN
G D
E M
O L
IT
IO
N
A
R E A B
EXISTING DEVICE TO REMAIN.
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL DEVICES IN THIS
SPACE, UNLESS NOTED OTHERWISE. REMOVE CONDUIT AND WIRE BACK TO
SOURCE.
DISCONNECT AND REMOVE EXISTING PANEL. REFER TO SHEET E-900 FOR
RELOCATED BRANCH CIRCUITS. EXTEND CONDUIT AND WIRE AS NEEDED TO
NEW PANEL SPECIFIED.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
CAP AND REMOVE ABANDONED ELECTRICAL CONDUIT AND WIRE IN THIS
LOCATION.
DISCONNECT AND REMOVE EXISTING DEVICE FOR CEILING MODIFICATIONS.
REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
EX Q
EX R
GFI
GFI
GFI
J
J
J
J
J J
J
J
C
(ON ROOF)
J
72"
AFF
J
J
C
C C
C
C
EWC
3 3
3 C J J
J
S
BC
GFI
AC
GFI
J J
S
J
CU
CU CU
CUH
EXIST. PNL
"P"
EXIST. PNL
"DP3"
5UV
UV
UV
S
S
S
8 8
7 7
EF
EF
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "B"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E9
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A B
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
CU
CU
CU
UV
UV
UV
CU
CU
UV
UV
EXIST. PNL
"N"
EXIST. PNL
"A"
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "C"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E10
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A C
CU
UV
CONV
1 1
CONV
CONV
CONV
EXIST. PNL
"M"
EXIST. PNL
"L"
EXIST. PNL
"X"
EXIST. PNL
"K"
EXIST. PNL
"J"
EXIST. PNL
"MDP"
9 9
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "D"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E11
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A D
CONV
CONV
PTAC
PTAC
PTAC
PTAC
CONV
PTAC
PTAC
CONV
EF
CONV
CONV
CONV
CONV
1 1
CONV
4 5
EXIST. PNL
"L"
EXIST. PNL
"X"EXIST. PNL
"MDP"
EXIST. PNL
"G"
EXIST. PNL
"H"
EXIST. PNL
"DP2"
EXIST. PNL
"F"
9 9
9 9
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "E"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E12
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A E
CONVCONVCONVCONV
F F
CU CU CU CU
1 1 1 1
22 F F 22
22 2 2
EXIST. PNL
"B"
EXIST.
PNL
"DP1A"
EXIST. PNL
"B1"
EXIST. PNL
"B2"
EXIST. PNL
"DP1"
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "F"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E13
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A F
CU
CU
CONV
F F
F F
CONV
CONV
CONV
CU
EXIST. PNL
"C1"
EXIST. PNL
"C2"
EXIST. PNL
"C"
CU
CU
CU
CU
CONV
F
CONV
CONV
CONV
F
F
F
EXIST. PNL
"D"
EXIST. PNL
"D1"
EXIST. PNL
"D2"
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "G"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E14
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A G
AHU
AHU
BLR
CUH
EF
CONV CONV CONV CONV CONV CONV
CONVCONV
1 1 1 1 1 1
CONV
EXIST. PNL
"F"
EXIST. PNL
"E"
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N
PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "H" (ALTERNATE)
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E15
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A H
UV
UV
CU
CU
CU
CU
EXIST. PNL
"W"
EXIST. PNL
"V"
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "I"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E16
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A I"
UV
UV
CU
CU
CU
EXIST. PNL
"V"
EXIST. PNL
"RP-AA"
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "J"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E17
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A J
UV
CU
CU
EXIST. PNL
"V"
EXIST. PNL
"T"
EXIST.
POOL "PNL
#1"
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "K"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E18
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A K
RTU
RTU
RTU
RTU
RTU
RTU
2 2
CU
CU
CU
EXIST. PNL
"A1"
EXIST. PNL
"A2"
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "L"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E19
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A L
CU
EXIST. PNL
"Q"
EXIST. PNL
"S"
EXIST. PNL
"T"
EXIST.
POOL "PNL
#1"
EXIST. PNL
"R"
B-1
B-2
B-1
B-26
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
EXISTING LIGHTING CONTROL DEVICE TO REMAIN.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE CONDUIT
AND WIRE BACK TO SOURCE.
REMOVE LIGHTING CONTROL DEVICE. REMOVE CONDUIT AND WIRE. PATCH
AND PAINT WALL TO MATCH EXISTING.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. REMOVE CONDUIT AND
WIRE BACK TO SOURCE.
DISCONNECT AND RELOCATE EXISTING EQUIPMENT. REMOVE ASSOCIATED
CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE EXISTING EQUIPMENT. ASSOCIATED CONDUIT
AND WIRE TO REMAIN FOR CONNECTION TO NEW EQUIPMENT.
DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE FOR CEILING
MODIFICATIONS. REINSTALL IN CEILING WHEN COMPLETE.
DEMOLITION NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - POWER DEMOLITION - AREA "M"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E20
P A R
T
IA
L F
L O
O R
P L A N
P
O W
E R
D E M
O L
IT
IO
N
A
R E A M
A E22
B E23
E E24
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
N COMPOSITE ELECTRICAL FLOOR PLAN - LIGHTING
E21
C O
M P O
S
IT
E E L E C
T R
IC
A L F
L O
O R
P L A N
L
IG
H
T
IN
G
D D
D
OS4
OS4
OS4
OS4 OS4
OS4 OS4
OS4
OC
D
OC
OC
OC OC
OC
OS4
OC
AEM
AEM
AEM
AEM
AEM
A
A
A
A
A A
AAA
A A A A
A A
AEM A
A A
A A
A
A
A A
AA
AEM AEM
AEM
XA
XA
XA
XA XA
XA
B2 B2
B2EM
B1 B1 B1
B1 B1 B1
B1
B1
B1
B1 B1
B1 B1
B1
B1EM
B1
B1EM
B1
B1 B1EM
C8B
C8B
C8B
C8B
C8B
C8B
C8B
C6 C6 C6
C12
C8
C8
C8
D
D
D
(E) (E) (E) (E) (E) (E)
(E)(E)(E)(E)
(E)
DEM
XA
OS4
OS4 OS4
OS4
XA
XB
XA
AEM
AEMAEM
AA
AAA
AA
D D
D
XA
AEM
XA
B1
Q-2
Q-2
Q-4
Q-4
Q-4
Q-4
Q-4
Q-4
Q-4 Q-4
Q-4
Q-4
Q-4
Q-4 Q-4
Q-4
Q-4
Q-4 Q-4
Q-4
Q-4
Q-4
Q-4
N-13
NEW
PNL "P"
EXIST.
PNL "DP3"
B1
OS4
OS4
OCD
OCD
OCD
OCD
OCD
OCD
OCD
OCD
OS4
D D
N-13
N-13
AA AEM
AA AEM
AA A
AA A
B2B2EMB2B2EM
EX
EX
A
A
A
A
A
A A
A AAEM
AEM
AEM
AEM
A A A A
A A A
A
A A A
DDDD
F F
FF
F
F F
F
F FF
F
F
D D
D
DDDDD
OS4
OS4
OC
OS4
OS4
OS4
OS4
OS4
OS4
OS4
OC OC OC
OC
ELECTRICAL KEY NOTES
FOR TEMPORARY ENCLOSURE DURING CONSTRUCTION, CONTRACTOR
SHALL INSTALL (3) B2 FIXTURES IN THIS AREA, WITH (1) FIXTURE HAVING
BATTERY BACKUP.
FIXTURES SHALL BE INSTALLED FOR TEMPORARY ENCLOSURE DURING
CONSTRUCTION.
FIXTURES SHALL BE CONTROLLED THROUGH INTEGRAL PHOTOCELL, AND
NEW BUILDING TIMECLOCK.
REINSTALLED LIGHT FIXTURE.
REUSE EXISTING LIGHTING CIRCUIT FOR NEW FIXTURES.
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - NEW LIGHTING - AREA "B"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E23
P A R
T
IA
L F
L O
O R
N KEY PLAN
NOT TO SCALE
P L A N
N
E W
L
IG
H T
IN
G A
R E A B
OS4
OS4
DEM
D
DEM
XA
XA
A
EM
A
EM
A
EM
A
EM
A
A
A
A
A
A
A
A
A
XA
TO ADJACENT
FIXTURES
ELECTRICAL KEY NOTES
CONTRACTOR SHALL REUSE EXISTING CIRCUIT, REMAINING FROM
DEMOLITION.
FIXTURES SHALL BE CONTROLLED THROUGH INTEGRAL PHOTOCELL, AND
NEW BUILDING TIMECLOCK.
REINSTALLED LIGHT FIXTURE.
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - NEW LIGHTING - AREA "E"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E24
P A R
T
IA
L F
L O
O R
N KEY PLAN
NOT TO SCALE
P L A N
N
E W
L
IG
H T
IN
G A
R E A
A E26
B E27
C E28
D E29
E E30
F E31
G E32
H E33
I E34
J E35K
E36
L E37
M E38
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
N COMPOSITE ELECTRICAL FLOOR PLAN - POWER
E25
C O
M P O
S
IT
E E L E C
T R
IC
A L F
L O
O R
P L A N
P
O W
E R
JJ
J
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
WASHER
WP
GFI
WP WP
(E)
FACP
TV
72"
AFF
DOOR OPERATOR
(TYP.)
J
J
J
TV
72"
AFF
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
44"
AFF
44"
AFF
42"
AFF
42"
AFF
42"
AFF
44"
AFF
44"
AFF
44"
AFF
44"
AFF
36"
AFF
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
EWC
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
44"
AFF
5 5
4 4
EWC
DRYER
DRYER
DRYER
WASHER
WASHER
Q-45
Q-51
Q-47
Q-53
WASHER
Q-49
Q-41
DRYER
Q-39
44"
AFF
NEW
PNL "Q"
NEW
PNL "R"
NEW
PNL "P"
Q-23
Q-54
Q-21
Q-19
Q-17
Q-15
Q-13
Q-11
Q-7 Q-9
Q-5
Q-3
Q-1
Q-22
Q-8 Q-10
Q-18
Q-52
Q-28 Q-30 Q-32 Q-34 Q-36 Q-20
Q-29 Q-31
Q-33 Q-35
Q-37
Q-28 Q-48
Q-50
Q-25
Q-27
Q-26
Q-46 Q-42
Q-40
Q-44
Q-12
Q-16 Q-14
R-19
R-21
R-23 R-25
R-27
R-29
R-31
R-34 R-34R-32
R-32
R-32
R-22
R-24
R-26
R-28
R-30
CR 7
CR
Q-38
44"
AFF
GFI
44"
AFF
GFI
TV
72"
AFF
12 12
WP
GFI
WP
GFI
Q-43 Q-24
ELECTRICAL KEY NOTES
ALL DEVICES IN THIS SPACE SHALL BE GFI PROTECTED.
CONTRACTOR SHALL PROVIDE AND INSTALL RECESSED GRADE MOUNTED
FLOOR BOX. FLOOR BOX TO BE WIREMOLD #895 WITH 895DCC COVER PLATE.
POUR CONCRETE MUD MAT AROUND BOX, ALL SIDES WITH 15 MIL VAPOR
BARRIER. INSTALL (3) 1-1/4" CONDUIT AND WIRE TO EACH FLOOR BOX. TOTAL
BENDS NOT TO EXCEED 270°.
CONTRACTOR SHALL PROVIDE AND INSTALL PASS AND SEYMOUR
RECESSED T.V. BOX. PROVIDE POWER AND 2" CONDUIT TO BOX FROM LAY-IN
CEILING. PROVIDE BLOCKING IN WALL. PROVIDE 2" CONDUIT FROM FLOOR
BOX TO T.V. BOX. VERIFY HEIGHT WITH INTERIOR ELEVATIONS AND OWNER
PRIOR TO INSTALLATION.
CONTRACTOR TO PROVIDE 1" EMT CONDUIT WITH PULL STRING IN
ACCESSIBLE CEILING SPACE.
CONTRACTOR TO PROVIDE 2" EMT CONDUIT WITH PULL STRING IN
ACCESSIBLE CEILING SPACE.
CONTRACTOR TO PROVIDE 4" EMT CONDUIT WITH PULL STRING IN
ACCESSIBLE CEILING SPACE.
CONTRACTOR SHALL PROVIDE AND INSTALL 4-11/16" DEEP SQUARE BOX
WITH 1" CONDUIT WITH SINGLE GANG PLASTER RING FOR CARD READER
STUBBED TO NEAREST CIRCULATION CEILING OR CABLE TRAY. VERIFY
FINAL LOCATION WITH OWNER PRIOR TO ROUGH-IN.
ALL DATA SHALL TERMINATE TO THIS ROOM. CONTRACTOR SHALL PROVIDE
AND INSTALL 4' PAINTED PLYWOOD BACKER BOARD ON REAR WALL.
CONTRACTOR SHALL PROVIDE AND INSTALL LEGRAND DEQUORUM SERIES
DQFP15UST FLIP UP UNIT FOR POWER MODULE ON COUNTERTOP.
CONTRACTOR SHALL PROVIDE AND INSTALL POWER FOR OWNER PROVIDED
SIGNAGE. VERIFY LOCATION WITH OWNER, PRIOR TO ROUGH-IN.
CONTRACTOR SHALL PROVIDE AND INSTALL DEVICES IN MILLWORK, WITH
GROMMET TO DESK TOP.
VERIFY FINAL LOCATION AND REQUIREMENTS WITH FURNITURE SUPPLIER.
RECEPTACLES IN THIS ROOM SHALL BE CONTROLLED BY ROOM
OCCUPANCY SENSORS.
CONTRACTOR SHALL EXTEND CONDUIT AND WIRE TO NEW LOCATION.
EXTEND ASSOCIATED BRANCH CIRCUITS TO NEW PANEL.
CONTRACTOR SHALL REUSE EXISTING CONDUIT AND WIRE FOR NEW
EQUIPMENT.
CONTRACTOR SHALL REUSE EXISTING CONDUIT AND WIRE FOR NEW
EQUIPMENT. CONTRACTOR SHALL REMOVE PHASE WIRE FROM PANEL
CONNECTION, FOR USE ON 2-POLE UNIT.
REINSTALLED DEVICE.
REINSTALLED EQUIPMENT. CONTRACTOR SHALL TIE INTO LOCAL
OCCUPANCY SENSOR.
NEW EXHAUST FAN. CONTRACTOR SHALL TIE INTO LOCAL OCCUPANCY
SENSOR.
1. CONTRACTOR SHALL PROVIDE AND INSTALL 4-11/16" DEEP SQUARE BOX WITH 1" CND
AND SINGLE GANG PLASTER RING, STUBBED TO NEAREST CIRCULATION CEILING OR
CABLE TRAY FOR ALL DATA DEVICES.
GENERAL ELECTRICAL NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - NEW POWER - AREA "A"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E26
P A R
T
IA
L F
L O
O R
P L A N
N
E W
P O
W E R
A
R E A A
RTU-2
208V-3Ø, 33.0A
RTU-3
208V-3Ø, 35.0A
RTU-4
208V-1Ø, 17.0A
CH-1
120V-1Ø, 17.5MCA
RTU-5
208V-3Ø, 35.0A
EF-3
120V-1Ø, 1/15HP
EF-2
120V-1Ø, 1/10HP
EF-1
120V-1Ø, 1/15HP
P-1,3,5
P-2,4,6
P-8,10,12
P-7,9
R-33
R-33
R-33
R-35
NEW PNL
"Q"
CU-1B
208V-1Ø, 15.1MCA
UV-1
120V-1Ø, 6.3MCA
CH-2
120V-1Ø, 17.5MCA
R-37
P-8
P-37,39
WP
NEW PNL
"R"
WP
WP
WP
WP
WP
WP
WPWP
GFI
P-41
WP
GFI
WP
GFI
R-51
R-51
J
R-53
J
S-15
J
S-15
WH-1
120V-1Ø, 3.0A
P-33
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - NEW MECHANICAL - AREA "A"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E27
P A R
T
IA
L F
L O
O R
P L A N
N
E W
M E C
H A N
IC
A L A
R E A A
CR
CR
CR
CR
CR
CR
CR
WASHER
WP
(E)
TV
72"
AFF
J
TV
72"
AFF
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI 44"
AFF
44"
AFF
44"
AFF
44"
AFF
36"
AFF
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
EWC
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
GFI
44"
AFF
44"
AFF
5 5
4 4
EWC
J
J
DRYER
DRYER
DRYER
WASHER
WASHER
Q-45
Q-51
Q-47
Q-53
WASHER
Q-49
Q-41
DRYER
Q-39
CR
44"
AFF
NEW
PNL "P"
EXIST.
PNL "DP3"
Q-23
Q-54
Q-21
Q-19
Q-17
Q-15
Q-13
Q-11
Q-7 Q-9
Q-5
Q-3
Q-1
Q-22
Q-8 Q-10
Q-18
Q-52
Q-28 Q-30 Q-32 Q-34 Q-36
Q-29 Q-31
Q-33 Q-35
Q-37
Q-28 Q-48
Q-50
Q-25
Q-27
Q-26
Q-46 Q-42
Q-40
Q-44
Q-12
Q-16 Q-14
R-34
EXISTING PNL "N"
DOOR OPERATOR
(TYP.)10
CR 7
Q-38
CR
P-10
P-12
P-14
P-14
P-16
P-18 P-20
P-22 P-24
P-15 P-17
P-26 P-28
P-21 P-25
44"
AFF
GFI
44"
AFF
GFI
TV
72"
AFF
WP
GFI
Q-43
RTU-1
208V-1Ø, 17.0A
FC-1
208V-1Ø, 1.0A
N-39,41
FED FROM HP-1
CU-3B
208V-1Ø, 17.5MCA
CU-2B
208V-1Ø, 15.1MCA
CU-1B
208V-1Ø, 15.1MCA
UV-2
120V-1Ø, 6.3MCA
UV-1
120V-1Ø, 6.3MCA
UV-3
120V-1Ø, 6.3MCA
HP-1
208V-1Ø, 12.0A
N-12
WP
N-38,40
P-6 P-8
P-34,36 P-37,39
WP WP
P-30,32
WP
WP
WP
GFI
WP
GFI
WP
GFI
P-41
N-35
N-35
WP
GFI
N-42
S
S
S
EF
EF-4
120V-1Ø, 1/15HP
WP
WP
ELECTRICAL KEY NOTES
ALL DEVICES IN THIS SPACE SHALL BE GFI PROTECTED.
CONTRACTOR SHALL PROVIDE AND INSTALL RECESSED GRADE MOUNTED
FLOOR BOX. FLOOR BOX TO BE WIREMOLD #895 WITH 895DCC COVER PLATE.
POUR CONCRETE MUD MAT AROUND BOX, ALL SIDES WITH 15 MIL VAPOR
BARRIER. INSTALL (3) 1-1/4" CONDUIT AND WIRE TO EACH FLOOR BOX. TOTAL
BENDS NOT TO EXCEED 270°.
CONTRACTOR SHALL PROVIDE AND INSTALL PASS AND SEYMOUR
RECESSED T.V. BOX. PROVIDE POWER AND 2" CONDUIT TO BOX FROM LAY-IN
CEILING. PROVIDE BLOCKING IN WALL. PROVIDE 2" CONDUIT FROM FLOOR
BOX TO T.V. BOX. VERIFY HEIGHT WITH INTERIOR ELEVATIONS AND OWNER
PRIOR TO INSTALLATION.
CONTRACTOR TO PROVIDE 1" EMT CONDUIT WITH PULL STRING IN
ACCESSIBLE CEILING SPACE.
CONTRACTOR TO PROVIDE 2" EMT CONDUIT WITH PULL STRING IN
ACCESSIBLE CEILING SPACE.
CONTRACTOR TO PROVIDE 4" EMT CONDUIT WITH PULL STRING IN
ACCESSIBLE CEILING SPACE.
CONTRACTOR SHALL PROVIDE AND INSTALL 4-11/16" DEEP SQUARE BOX
WITH 1" CONDUIT WITH SINGLE GANG PLASTER RING FOR CARD READER
STUBBED TO NEAREST CIRCULATION CEILING OR CABLE TRAY. VERIFY
FINAL LOCATION WITH OWNER PRIOR TO ROUGH-IN.
ALL DATA SHALL TERMINATE TO THIS ROOM. CONTRACTOR SHALL PROVIDE
AND INSTALL 4' PAINTED PLYWOOD BACKER BOARD ON REAR WALL.
CONTRACTOR SHALL PROVIDE AND INSTALL LEGRAND DEQUORUM SERIES
DQFP15UST FLIP UP UNIT FOR POWER MODULE ON COUNTERTOP.
CONTRACTOR SHALL PROVIDE AND INSTALL POWER FOR OWNER PROVIDED
SIGNAGE. VERIFY LOCATION WITH OWNER, PRIOR TO ROUGH-IN.
CONTRACTOR SHALL PROVIDE AND INSTALL DEVICES IN MILLWORK, WITH
GROMMET TO DESK TOP.
VERIFY FINAL LOCATION AND REQUIREMENTS WITH FURNITURE SUPPLIER.
RECEPTACLES IN THIS ROOM SHALL BE CONTROLLED BY ROOM
OCCUPANCY SENSORS.
CONTRACTOR SHALL EXTEND CONDUIT AND WIRE TO NEW LOCATION.
EXTEND ASSOCIATED BRANCH CIRCUITS TO NEW PANEL.
CONTRACTOR SHALL REUSE EXISTING CONDUIT AND WIRE FOR NEW
EQUIPMENT.
CONTRACTOR SHALL REUSE EXISTING CONDUIT AND WIRE FOR NEW
EQUIPMENT. CONTRACTOR SHALL REMOVE PHASE WIRE FROM PANEL
CONNECTION, FOR USE ON 2-POLE UNIT.
REINSTALLED DEVICE.
REINSTALLED EQUIPMENT. CONTRACTOR SHALL TIE INTO LOCAL
OCCUPANCY SENSOR.
NEW EXHAUST FAN. CONTRACTOR SHALL TIE INTO LOCAL OCCUPANCY
SENSOR.
1. CONTRACTOR SHALL PROVIDE AND INSTALL 4-11/16" DEEP SQUARE BOX WITH 1" CND
AND SINGLE GANG PLASTER RING, STUBBED TO NEAREST CIRCULATION CEILING OR
CABLE TRAY FOR ALL DATA DEVICES.
GENERAL ELECTRICAL NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - NEW POWER - AREA "B"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E28
P A R
T
IA
L F
L O
O R
N KEY PLAN
NOT TO SCALE
P L A N
N
E W
P O
W E R
A
R E A B
FC-1
208V-1Ø, 1.0A
N-39,41
FED FROM HP-1
CU-5B
208V-1Ø, 15.1MCA
CU-4B
208V-1Ø, 17.5MCA
CU-3B
208V-1Ø, 17.5MCA
UV-3
120V-1Ø, 6.3MCA
UV-4
120V-1Ø, 6.3MCA
UV-5
120V-1Ø, 6.3MCA
UV-6
120V-1Ø, 6.3MCA
UV-7
120V-1Ø, 6.3MCA
CU-7B
208V-1Ø, 15.1MCA
CU-6B
208V-1Ø, 15.1MCA
HP-1
208V-1Ø, 12.0A
N-12
N-14
N-16
WP
WP
WP
N-31,33
WP
N-32,34
WP
A-8
A-16
A-38,40
A-32,34
EXIST. PNL
"DP3"
EXIST. PNL
"N"
EXIST. PNL
"A"
WP
WP
GFI
N-35
WP
GFI
WP
GFI
WP
GFI
N-42
N-42
WP
GFI
N-36
WP
GFI
A-42
A-36
ELECTRICAL KEY NOTES
RELOCATED EQUIPMENT. CONTRACTOR SHALL EXTEND ASSOCIATED
BRANCH CIRCUIT CONDUIT AND WIRE TO NEW LOCATION.
CONTRACTOR SHALL PROVIDE AND INSTALL POWER FOR OWNER PROVIDED
SIGNAGE. VERIFY LOCATION WITH OWNER, PRIOR TO ROUGH-IN.
CONTRACTOR SHALL REUSE EXISTING CONDUIT AND WIRE FOR NEW
EQUIPMENT.
CONTRACTOR SHALL REUSE EXISTING CONDUIT AND WIRE FOR NEW
EQUIPMENT. CONTRACTOR SHALL REMOVE PHASE WIRE FROM PANEL
CONNECTION, FOR USE ON 2-POLE UNIT.
CONTRACTOR SHALL PROVIDE AND INSTALL NEW CONDUIT AND WIRE FOR
NEW EQUIPMENT.
EXHAUST FAN SHALL BE CONTROLLED BY NEW TIMECLOCK. CONFIRM TIME
SCHEDULING WITH OWNER.
REMOVE EXISTING PNEUMATIC INTERLOCK WITHIN STARTER, AND CONNECT
TO NEW CONTROL PANEL FOR CONTROLS.
CONTRACTOR SHALL PROVIDE CIRCUIT TO TRANSFORMER, FOR CONTROL
VALVE POWER.
1. CONTRACTOR SHALL PROVIDE AND INSTALL 4-11/16" DEEP SQUARE BOX WITH 1" CND
AND SINGLE GANG PLASTER RING, STUBBED TO NEAREST CIRCULATION CEILING OR
CABLE TRAY FOR ALL DATA DEVICES.
GENERAL ELECTRICAL NOTES
SCALE: 1/8" = 1'-0"
0 1 5 10 20
N PARTIAL FLOOR PLAN - NEW POWER - AREA "C"
J C
IS
D
T O
R R
A N
T C
E N
T E R
A D
D
IT
IO
N
S
R E N
O V A T
IO
N S
M A
T R
I X
E29
P A R
T
IA
L F
L O
O R
N KEY PLAN
NOT TO SCALE
P L A N
N
E W
P O
W E R
A
R E A C
File details come from the government source that posted it. Updated .