Addendum #2 Patrick Henry Windows.pdf

PDF 189 KB Posted

Attached to
Patrick Henry CC Window Replacement
Solicitation number
83980
Issued by
Patrick County, Virginia

About this file

This is Addendum No. 002 issued by Thompson & Litton Engineers Architects for the Patrick Henry Correctional Unit Window Replacement project (Project Code: 799-10887-1214) in Virginia. The addendum modifies the original bidding documents dated November 25, 2024, extending the bid submission deadline to February 5, 2025 at 2:00 PM, with bids to be received electronically through eVA. A virtual bid opening will be held on February 6, 2025 at 2:00 PM. The deadline for questions is January 24, 2025 at 12:00 PM. The project involves window replacement with new windows featuring anodized dark bronze finish.

The addendum provides technical clarifications regarding window installation details, specifically addressing concerns about window sill demolition and CMU work. It specifies that 1/4" polycarbonate shall be installed in the windows with U-Factor per manufacturer's designation, modifying the original U-Value requirement of 0.35. The contractor must exercise extreme care when removing existing window frames to avoid damage to glazed CMU and existing block/mortar. If damage occurs, specific replacement requirements are detailed for CMU units measuring 3-5/8"x7-5/8"x15-5/8" with bullnose finish.

View the file

Other files

File Type Posted
Bid Tab —
Addendum #1 Patrick Henry Windows.pdf PDF
Addendum #2 Patrick Henry Windows.pdf PDF
Invitation for Bids.pdf PDF
Addendum #1 Patrick Henry Windows.pdf PDF
Addendum #2 Patrick Henry Windows.pdf PDF
Invitation for Bids.pdf PDF
Addendum #1 Patrick Henry Windows.pdf PDF
Addendum #2 Patrick Henry Windows.pdf PDF
Invitation for Bids.pdf PDF
Notice of Intent to Award —
Approval to Advertise.pdf PDF
Invitation for Bids.pdf PDF
Addendum #1 Patrick Henry Windows.pdf PDF
Approval to Advertise.pdf PDF
Invitation for Bids.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ENGINEERS ARCHITECTS

T&L 100 Fifth Street, Suite 400 Bristol, Tennessee 37620 tel: 423.989.9491 fax: 423.989.9010 www.T-L.com

ADDENDUM NO. 002

TO: All Plan Holders

RE: Patrick Henry Correctional Unit

-Window Replacement

Project Code: 799-10887-1214

T&L Project No. 16841

DATE: January 15, 2025

REVISED BIDS RECEIVED DATE: February 5, 2025

BIDS RECEIVED TIME: 2:00 P.M.

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated November 25, 2024, as noted below. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject Bidder to disqualification.

This Addendum consists of 2 pages.

CHANGE TO THE BIDS RECEIVED DATE:

The deadline for submitting bids has been extended to 2:00 P.M. sharp, on February 5, 2025. Sealed bids will be received electronically through eVA. It is the responsibility of the Bidder (not the agency) to ensure bids are delivered to the specified location by the date and time stated for the receipt of bids. The bids will be read aloud publicly via a virtual bid opening at 2:00 P.M., on February 6, 2025.

CLARIFICATIONS AND ANSWERS TO PRE-BID QUESTIONS:

1. Question: Drawings call out baked enamel finish. Color? AAMA 2603, AAMA 2604, or AAMA 2605?

Specifications call for Anodized finish “Dark Bronze”.

Answer: The new windows shall have an anodized dark bronze finish.

CLARIFICATIONS TO THE DRAWINGS:

1. Question: The existing window sill demolition detail: This detail does not appear to accurately depict the actual condition. Please provide a revised detail showing the window being recessed behind the glazed CMU wainscot. This glazed tile will need to be removed or cut as part of the

Addendum No. 002

Patrick Henry Correctional Unit -Window Replacement

Project Code: 799-10887-1214

T&L Project No. 16841

January 16, 2025 Page 2

T&L www.T-L.com window replacement, and we will need a detail on the necessary interior repairs required once the new window is installed.

Answer: The same window condition existed at other VDOC facilities and was successfully replaced without damage to the existing glazed CMU at the sill or the CMU at the jambs and head.

The Contractor shall be extremely careful when removing the existing window frames so as to not damage the existing glazed CMU at the sill or the CMU at the jambs and head. If the glazed CMU

Is damaged at the window sill, then the three glazed CMU under the window shall be replaced with 3-5/8”x7-5/8”x15-5/8” (or size matching the existing glazed CMU) bullnose CMU grouted in place. No revised drawing detail provided.

2. Question: The existing window sill demolition detail: This detail does not accurately depict the actual condition. Please provide a detail showing the window being recessed and the interior block/mortar covering up part of the window sill. This block/mortar will have to be removed as part of the window replacement, and we will need a detail on the necessary interior repairs required once the new window is installed. This might be the condition around the entire window perimeter. Please verify.

Answer: The same window condition existed at other VDOC facilities and was successfully replaced without damage to the existing block/ mortar at the sill or the CMU at the jambs and head. The Contractor shall be extremely careful when removing the existing window frames so as to not damage the existing block/ mortar at the window sill or the CMU at the jambs and head. If the block/ mortar Is damaged at the window sill, then the block/ mortar under the window shall be replaced with one full course of 3-5/8”x7-5/8”x15-5/8” (or size matching the existing CMU) bullnose CMU toothed-in and grouted in place for the full width of the window. No revised drawing detail provided.

CLARIFICATIONS TO THE PROJECT MANUAL:

1. Question: Drawings A601-602-603 show the new windows glazed with polycarbonate.

Spec Section 08-5113 Page 5 Paragraph 2.04 calls for a U-Value of 0.35.

Window manufacturers are saying you can’t get a U-Value that low with only 1/4-INCH polycarbonate. Will the U Value requirement be dropped or the glazing package changed?

Answer: The 1/4” polycarbonate shall be installed in the windows. The U-Factor shall be per manufacturer’s designation.

CLARIFICATIONS TO THE BIDDING REQUIREMENTS:

1. Question: Would it be possible to extend the Bid by two (2) weeks due to finding out the difficulty of window removal?

Answer: Yes, the Bid date shall be changed.

Bids will be received on February 5th, 2025 at 2:00 pm.

Bids will be open on February 6th, 2025 at 2:00 pm.

Deadline for questions will be January 24th, 2025 at 12:00 pm (noon).

Enclosures: None.