Addendum 2-B-Eagle View Roof Measurement Report.pdf

PDF 2 MB Posted

Attached to
INS130 Replace Hail Damaged Roofs McCandless VCLC AFB
Solicitation number
IFB1 IHKA 2026000138 4
Issued by
Pueblo County, Colorado

About this file

This is a Precise Aerial Roof Measurement Report prepared by VeriClaim Inc. using Eagle View Technologies for a commercial property located at 903 Moore Drive, Florence, Colorado, in support of an insurance claim (P097052) related to hail damage sustained on June 8, 2024. The report provides comprehensive three-dimensional modeling and measurements of the roof structure, documenting a total roof area of 46,787 square feet across 34 roof facets with a predominant pitch of 2/12. The property includes 91 penetrations (such as vents and skylights) totaling 743 square feet, with significant linear measurements including 1,039 feet of ridges, 313 feet of valleys, 386 feet of rakes, 2,029 feet of eaves, and 376 feet of parapet walls. The report was completed on June 25, 2024, and includes detailed aerial imagery from multiple angles (north, south, east, and west), length and pitch diagrams, area diagrams for each roof facet, and penetrations documentation.

The report incorporates waste calculation tables based on varying waste percentages (0 to 22 percent) to assist in material estimation, with total roof area requiring approximately 467.9 to 570.8 squares of roofing material depending on the waste factor applied. Roof pitch analysis indicates that 82.9 percent of the roof has a 2/12 pitch, with additional areas of 0/12 (11.1 percent), 3/12 (5.1 percent), 4/12 (0.3 percent), and 1/12 (0.5 percent) pitches. The property is classified as commercial with no structural changes documented in the four years preceding the assessment. The report includes a disclaimer noting that while measurements are provided with reference to Eagle View's guarantee, contractors are advised to conduct preliminary site surveys to verify findings, and any measurement errors will result in a refund of report fees rather than additional compensation.

View the file

Other files

File Type Posted
IFB Hail.docx DOCX document
Addendum 1.docx DOCX document
Addendum 2.docx DOCX document
Walkthrough.pdf PDF
Addendum3.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Precise Aerial Roof Measurement Report

Prepared for you by VeriClaim Inc.

903 Moore Dr, Florence, CO 81226

Sedgwick ClaimsReady™ Report June 25, 2024

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152;

8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Measurements provided by www.eagleview.com www.eagleview.com/Guarantee.aspx

903 Moore Dr, Florence, CO 81226

In this 3D model, facets appear as semi-transparent to reveal overhangs.

Report Details Roof Details Report Contents

Report: 59810081 Claim Information ClaimInfo: DEN24177410 ClaimNumber: P097052 DateOfLoss: 2024-06-08

Total Roof Area = 46,787 sq ft Total Roof Facets = 34 Predominant Pitch = 2/12 Number of Stories >1 Total Ridges/Hips = 1,085 ft Total Valleys = 313 ft Total Rakes = 386 ft Total Eaves = 2,029 ft Total Penetrations = 91 Total Penetrations Perimeter = 728 ft Total Penetrations Area = 743 sq ft

Images Length Diagram Pitch Diagram Area Diagram Notes Diagram Penetrations Diagram Report Summary

Contact:

Address:

http://www.eagleview.com/ http://www.eagleview.com/Guarantee.aspx

903 Moore Dr, Florence, CO 81226 June 25, 2024

Report: 59810081 Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 2

Images The following aerial images show different angles of this structure for your reference.

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 3

North Side

South Side

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 4

East Side

West Side

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 5

Length Diagram Total Line Lengths:

Ridges = 1,039 ft Hips = 46 ft

Valleys = 313 ft Rakes = 386 ft Eaves = 2,029 ft

Flashing = 232 ft Step flashing = 529 ft Parapets = 376 ft

Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5 feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9).

+9

17107

131 23

191955

57 28 28 78

54 57

+8

S

N W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve d.

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 6

Pitch Diagram Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 2/12.

Note: This diagram contains labeled pitches for facet areas larger than 20 square feet. In some cases, pitch labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. If present, a value of "F" indicates a flat facet (no pitch).

F

F

S

N W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 7

Area Diagram Total Area = 46,787 sq ft, with 34 facets.

Note: This diagram shows the square feet of each roof facet (rounded to the nearest foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof facet (rounded to the nearest square foot after being totaled).

812763

S

N W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 8

Notes Diagram Roof facets are labeled from smallest to largest (A to Z) for easy reference.

H

O A

AA

AH

G

I

Z

R

W

AD

P M

F

AF

B

AG

AB

V

C

Q

AC

J

L

Y

K

E X

N

AE

D

U

S

T

S

N W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er

903 Moore Dr, Florence, CO, 81226 June 25, 2024

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S.

Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770;

8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 9

Penetrations Notes Diagram Penetrations are labeled from smallest to largest for easy reference.

Total Penetrations = 91 Total Penetrations Area = 743 sq ft Total Penetrations Perimeter = 728 ft Total Roof Area Less Penetrations = 46,044 sq ft

777984

17 65

75 85

5852 81

49 48 47

444342

353469

68 32

S

N W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 10

Report Summary Below is a measurement summary using the values presented in this report.

All Structures

Areas per Pitch Roof Pitches Area (sq ft) % of Roof

0/12 1/12 2/12 3/12 4/12

5206.7 250.4 38778.6 2408.5 142.2 11.1% 0.5% 82.9% 5.1% 0.3%

The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch.

Waste Calculation Table

Waste % 0% 10% 12% 15% 17% 20% 22% Area (sq ft) 46,787 51465.7 52401.4 53805.1 54740.8 56144.4 57080.1 Squares 467.9 514.7 524.0 538.1 547.4 561.4 570.8

This table shows the total roof area and squares (rounded up to the nearest decimal) based upon different waste percentages. The waste factor is subject to the complexity of the roof, individual roofing techniques and your experience. Please consider this when calculating appropriate waste percentages. Note that only roof area is included in these waste calculations. Additional materials needed for ridge, hip, valley, and starter lengths are not included.

Penetrations

Area (sq ft) Perimeter (ft)

1-55 56 57-59 60-67 68-75 76-80 81 82 83 84

0.2 0.3 1 2.2 4 6.3 9 37.5 30 42.2 2 2 4 6 8 10 12 25 26 26

Area (sq ft) Perimeter (ft)

85 86 87 88 89 90 91

35 32.5 58.5 58.9 63 113.3 167.2 27 31 31 32 37 86.4 108

Any measured penetration smaller than 3x3 feet may need field verification. Accuracy is not guaranteed. The total penetration area is not subtracted from the total roof area.

All Structures Totals

Total Roof Facets = 34 Total Penetrations = 91

Lengths, Areas and Pitches Ridges = 1,039 ft (16 Ridges) Hips = 46 ft (2 Hips).

Valleys = 313 ft (19 Valleys) Rakes † = 386 ft (24 Rakes) Eaves/Starter ‡ = 2,029 ft (40 Eaves) Drip Edge (Eaves + Rakes) = 2,415 ft (64 Lengths) Parapet Walls = 376 (17 Lengths).

Flashing = 232 ft (25 Lengths) Step flashing = 529 ft (50 Lengths) Total Penetrations Area = 743 sq ft Total Roof Area Less Penetrations = 46,044 sq ft Total Penetrations Perimeter = 728 ft Predominant Pitch = 2/12 Total Area (All Pitches) = 46,787 sq ft

Property Location Longitude = -105.1221636 Latitude = 38.3711057

Notes This was ordered as a commercial property. There were no changes to the structure in the past four years.

S

N W

E

E ag le

V ie w T ec hn ol og ie s, In c.

, A ll

R ig ht s

R es er ve d.

† Rakes are defined as roof edges that are sloped (not level).

‡ Eaves are defined as roof edges that are not sloped and level.

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Sedgwick Page 11

Parapet Wall Area Table Wall Height (ft) Vertical Wall Area (sq ft)

1 2 3 4 5 6 7 376 752 1128 1504 1880 2256 2632

This table provides common parapet wall heights to aid you in calculating the total vertical area of these walls. Note that these values assume a 90 degree angle at the base of the wall. Allow for extra materials to cover cant strips and tapered edges.

Online Maps Online map of property http://maps.google.com/maps?f=g&source=s_q&hl=en&geocode=&q=903+Moore+Dr,Florence,CO,81226 Directions from Sedgwick to this property http://maps.google.com/maps?f=d&source=s_d&saddr=325+Sedona+Dr,Colorado+Springs,CO,80921&daddr=903+Moore+Dr,Florenc e,CO,81226

Enclosed is your ClaimsReady report. Please click the link to supplement your report with a walls report that includes areas of facets and cut-outs, line lengths, a notes diagram, and waste table calculations. Request a walls report.

http://maps.google.com/maps?f=g&source=s_q&hl=en&geocode=&q=903+Moore+Dr,Florence,CO,81226 http://maps.google.com/maps?f=d&source=s_d&saddr=325+Sedona+Dr,Colorado+Springs,CO,80921&daddr=903+Moore+Dr,Florence,CO,81226 http://maps.google.com/maps?f=d&source=s_d&saddr=325+Sedona+Dr,Colorado+Springs,CO,80921&daddr=903+Moore+Dr,Florence,CO,81226 http://maps.google.com/maps?f=d&source=s_d&saddr=325+Sedona+Dr,Colorado+Springs,CO,80921&daddr=903+Moore+Dr,Florence,CO,81226 http://maps.google.com/maps?f=d&source=s_d&saddr=325+Sedona+Dr,Colorado+Springs,CO,80921&daddr=903+Moore+Dr,Florence,CO,81226 https://my.eagleview.com/PropertyDetails.aspx?upgradeReportId=WTVnUTZUVk01MFR3VGZ5Q1EyOUd2UT09

Claim: P097052

© 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578;

8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749. Other Patents Pending.

Important Legal Notice and Disclaimer

Notice and Disclaimer

No Warranty: The Copyrighted Materials are provided to you "as is," and you agree to use it at your own risk.

EagleView Technologies makes no guarantees, representations or warranties of any kind, express or implied, arising by law or otherwise, including but not limited to, content, quality, accuracy, completeness, effectiveness, reliability, fitness for a particular purpose, usefulness, use or results to be obtained from the Copyrighted Materials.

Contractors agree to always conduct a preliminary site survey to verify Roof Report ordered. In the event of an error in a Report, your sole remedy will be a refund of the fees paid by you to obtain this Report.

File details come from the government source that posted it. Updated .