Addendum 1 26054 HartwickPinesExhibits.pdf

PDF 4 MB Posted

Attached to
751/26054. HJD; Hartwick Pines SP - Visitor Center Renovation
Solicitation number
RFQ 171 260000000302 3
Issued by
Crawford County, Michigan

About this file

Addendum 1 to Construction Bid Documents for Hartwick Pines State Park Visitor Center Renovation

This is Construction Bid Addendum No. 1 issued by the Michigan Department of Technology, Management and Budget, State Facilities Administration Design & Construction Division for the DNR Hartwick Pines State Park Visitor Center Exhibit Space Renovation project located in Grayling, Michigan (Crawford County). The project (File Number 751/26054.HJD) involves renovation of exhibit space with professional oversight from Integrated Architecture and project direction by Heather DeKorte. The bid opening date is June 10, 2026. The addendum incorporates five primary items: acceptance of a Pre-Bid Meeting sign-in sheet dated May 21, 2026; clarification that 115 reception lighting fixtures are existing and to remain per drawings; detailed electrical installation requirements for new conduits and conductors in exhibit space locations, including revisions to sheet E0.1 General Electric Note 6 to permit exposed conduits "Unless Noted Otherwise" with comprehensive specifications for conduit sizing, routing, support, connections, and penetrations in compliance with NFPA 70 and National Electrical Code standards; approval of a Saniflow Corporation SpeedFlow Plus electric hand dryer substitution (Model M17ACS-UL) for the washroom; and approval of a Saniflow Corporation BabyMedi baby changing station substitution (Model CP0016HCS-ASTM with recessed kit KT0016HCS) for public-use washroom accessories. All addenda must be acknowledged by bidders in the Bid Summary and Bid Form, with failure to acknowledge potentially resulting in bid rejection.

The substitution requests were submitted by Saniflow Corporation on May 22, 2026, and were approved as noted by the architect on May 26 and May 27, 2026, respectively, contingent upon submittal in accordance with Specification Section 01 25 00 Substitution Procedures. The SpeedFlow Plus hand dryer features a 1/16-inch thick stainless steel cover in satin finish, adjustable motor speed (23,000-32,000 RPM), infrared sensor, 500-watt heating element, HEPA filter, total power consumption of 180-850 watts, drying time of 10-12 seconds, noise level of 57-65 dBA, and dimensions of 10½" x 11½" x 4". The BabyMedi changing station features bacterial-resistant polypropylene with stainless steel exterior, Biocote antimicrobial additive, 80-unit liner dispenser capacity, maximum support of 220 pounds, dimensions of 33⅞" x 3⅞" (closed) / 22½" (open) x 18⅞", and a 5-year limited warranty. The recessed kit (KT0016HCS) is constructed of AISI 304 stainless steel with satin finish, dimensions of 36¼" x 4" x 27⅛", and a net weight of 14 pounds. Both substitutions were determined to be equal or superior to specified products with equivalent warranties and maintenance service availability.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DTMB-0414 (Rev 6/25)

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND

BUDGET

State Facilities Administration Design & Construction Division

CONSTRUCTION BID ADDENDUM NO. 1

This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.

TO:

ALL BIDDERS

DATE ISSUED

5/29/2026

PROJECT NAME

DNR- Hartwick Pines State Park- Visitor Center Exhibit Space Reno.

Grayling, MI

FILE NUMBER

751/26054.HJD

PROFESSIONAL

Anna Kindt, Integrated Architecture

PROJECT DIRECTOR

Heather DeKorte

BID OPENING DATE:

6/10/2026

ADDENDUM ITEMS: (attach additional sheets and drawings if required)

- 1. See attached Pre-Bid Meeting sign in sheet.

- 2. 115 Reception lighting fixtures are existing to remain, per drawings.

- 3. Exhibit Space installation requirements for new conduits and conductors for new lighting locations:

a. Revise sheet E0.1 General Electric Note number 6 portion that states “There shall be no exposed conduits” to include “Unless Noted Otherwise”

b. Install conduits per the following direction:

• Coordination:

o Coordinate minimum sizes of conduits with actual type and quantity of conductors to be installed, including adjustments for conductor sizes increased for voltage drop.

Minimum conduit size, unless otherwise indicated:

• Branch Circuits: 3/4-inch (21 mm) trade size.

• Branch Circuit Homeruns: 3/4-inch (21 mm) trade size.

• Where conduit size is not indicated, size to comply with NFPA 70 but not less than applicable minimum size requirements specified.

o Coordinate arrangement of conduits with structural members, ductwork, piping, equipment, and other potential conflicts.

o Verify exact conduit termination locations required for boxes, enclosures, and Exhibit equipment.

• Conduit or tubing shall be installed in a manner which complies with all applicable provisions of the National Electrical Code (NFPA 70) and at least six inches from parallel runs of steam pipes, flues, or hot water pipes.

• Provide conduit, fittings, supports, and accessories required for complete raceway system.

• Provide products listed, classified, and labeled as suitable for purpose intended.

• Conduit Routing:

o Unless dimensioned, conduit routing indicated is diagrammatic.

o When conduit destination is indicated without specific routing, determine exact routing required.

o Conceal conduits unless specifically indicated to be exposed.

o Conduits in the following areas may be exposed, unless otherwise indicated:

Electrical rooms.

Mechanical equipment rooms.

Lighting branch circuits in the Exhibit space.

- Paint lighting branch circuits in Exhibit Space to match adjacent surface.

As noted on the drawings.

o Unless otherwise approved, do not route exposed conduits:

Across floors.

Across roofs.

Across top of parapet walls.

Across building exterior surfaces.

o Route conduits parallel or perpendicular to building structure and surfaces, following surface contours where practical.

o Arrange conduit to maintain adequate headroom, clearances, and access.

o Arrange conduit to provide no more than equivalent of four 90-degree bends between pull points.

o Route conduits above water and drain piping where possible.

o Maintain minimum clearance of 6 inches (150 mm) between conduits and piping for other systems.

o Maintain minimum clearance of 12 inches (300 mm) between conduits and hot surfaces. This includes, but is not limited to:

Heaters.

Hot water piping.

o Group parallel conduits in same area.

• Conduit Support:

o Secure and support conduits in accordance with NFPA 70 using suitable supports and methods approved by authorities having jurisdiction.

o Provide independent support from building structure. Do not provide support from piping, ductwork, ceiling support system, or other systems.

o Use conduit strap to support single surface-mounted conduit.

• Connections and Terminations:

o Use suitable adapters where required to transition from one type of conduit to another.

o Provide insulating bushings, insulated throats, or listed metal fittings with smooth, rounded edges at conduit terminations to protect conductors.

o Secure joints and connections to provide mechanical strength and electrical continuity.

• Penetrations:

o Do not penetrate or otherwise notch or cut structural members, including footings and grade beams, without approval of Structural Engineer.

o Make penetrations perpendicular to surfaces unless otherwise indicated.

o Provide sleeves for penetrations as indicated or as required to facilitate installation. Set sleeves flush with exposed surfaces unless otherwise indicated or required.

o Install firestopping to preserve fire resistance rating of partitions and other elements.

- 4. See attached substitution request: Saniflow Corporation, Electric Hand Dryer, Substitution Reviewed as Noted.

- 5. See attached substitution requestion: Saniflow Corporation, Baby Changing Station, Substitution Reviewed as Noted.

ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.

PROFESSIONAL: DATE: 5/29/2026

APPROVED BY:

PROJECT DIRECTOR: DATE: Click to enter date 6/2/2026

© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314

Form Version: January 2013 CSI Form 1.5C

SUBSTITUTION

REQUEST

(During the Bidding/Negotiating Stage)

Proposed Substitution:

Manufacturer: Saniflow Corp.

Trade Name:

Phone:

Model No:

Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.

The Undersigned certifies:

• Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

• Same warranty will be furnished for proposed substitution as for specified product.

• Same maintenance service and source of replacement parts, as applicable,is available.

• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

• Proposed substitution does not affect dimensions and functional clearances.

• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution.

Submitted by:

Signed by:

Firm:

Address:

Telephone:

A/E’s REVIEW AND ACTION

• Substitution approved - Make submittal in accordance with Specification Section 01 25 00 Substitution Procedures.

• Substitution approved as noted - Make submittal in accordance with Specification Section 01 25 00 Substitution Procedures.

• Substitution rejected-Use specified materials.

• Substitution Request received too late - Use specified materials. Signed by: Date:

Supporting Data Attached: • Drawings ☐Product Data • Samples ☐ Tests ☐ Reports ☐

305-424-2433

M17ACS-UL

Hellen Olivares

Speedflow Plus

Saniflow a Mediclinics Company Address :3325 NW 70th Ave ., Miami FL, 33122

Saniflow Corp

3325 NW 70th Ave, Miami, FL, 33122

305-424-2433 x. 2022

Hartwick Pines State Park - Visitor Center Renovation

3612 State Park Dr, Grayling, MI, 49738 (Crawford County)

To: Integrated Architecture

Re: Substitution/Equal

Description: Public-Use Washroom Accessories

Article/Paragraph: 2.2

Specification: Toilet, Bath, and Laundry Accessories

Section: 102800 Page: 2

Substitution Request No.

From: Saniflow Corp. / Attn: Hellen Olivares

Date: 5/22/2026

A/E Project Number: 20251010

Hellen Olivares

5/26/26

1 BuildingGreen

'APPROVED

SpeedFlow® Plus

SPEEDFLOW PLUS

(M17A, M17AF, M17AC, M17ACS,

M17AB)

Efficient, adjustable RPM, ADA compliant, and

5 year warranty

Technical Specifications Speedflow Plus 100-120V; 208V; 220-240V

20-27 CFM

250 mph/ 22,000 LFM

180-850 W H. Element OFF: 2.5 - 3.5 A

H. Element ON: 4.8 - 7 A

Dyson Airblade V 110-120 V; 208- 240 V

28 CFM

420 mph/ 36,000 LFM

1000 W Low Voltage: 11.7 A High Voltage: 7.3 A

Electrical Effective Airflow Max Air Velocity

Total Power

Consumption

Motor type

High pressure class F, with self-resettable safety cut-out and adjustable speed 23,000-32,000 rpm via potentiomenter to adjust consumption. Motor has been configured to have a smooth start to extend its life.

Dyson digital motor - V4 brushless DC motor

Heating element (W) Construction materials

0 -500 W (jumper for on/ off option) Steel, Stainless Steel, and cast iron

None Polycarbonate ABS Casing

Air temperature – (at 4” distance/ T amb. 77 ºF) 93-109 ºF 32 - 104 ºF

List Price $475.00 $949.00

Color finish 5 finishes: Stainless steel one-piece cover bright & satin finish, white epoxy, black graphite, or white porcelain in cast Iron

AB12 Sprayed Nickel molded plastic or AB12 White molded plastic

Dimensions 10 1/2”H x 11 1/2”W x 4”D 9 1/4" H x 15 1/2" W x 4" D

Operation Touch-free infrared sensor. Auto 2 second shutoff after hands are removed Touch-free proximity capacity sensor

Weight 8.4 Lbs. 6.17 Lbs.

Safety shut off Automatic disconnection after 30 seconds of continous use. Automatic disconnection after 30 seconds of continous use

Drying time Limited Warranty

Noise Level Sensor

HEPA Filter Adjustable motor Protection Level

BuildingGreen Approved Contributes to LEED certification

ADA surfaced mounted

10 -12 seconds 5 years

57-65 db(A) Adjustable 2”-8” infrared

Yes Yes

IP23

Yes Yes Yes

12 seconds 5 years

79 db(A) Proximity capacity sensor

Yes No

IP24

Yes Yes Yes

The Speedflow M17 has improved drying times, exceptional efficiency, and continued versatily. Now with a HEPA Filter included to purify air from dust particles, pollen, and other allergens.

mph

M17A-UL · M17AF-UL · M17AB-UL · M17AC-UL · M17ACS-UL

COMPONENTS AND MATERIALS

TECHNICAL SPECIFICATIONS

• 3/16” thick cast iron or 1/16” thick stainless steel one piece cover.

• High pressure class F motor, with self.resetable safety cut-out and adjustable speed between 23 ,000 and 32,000 rpm..

• HEPA filter medium cartridge.

• ADA compliant (no recessed kit needed).

• Universal Voltage (from 100 to 240 V).

• Sensors come with a vandal-resistant polycarbonate viewing window.

• Cover fixed to the base by means of 2 vandal-proof lock screws and lock with special Speedflow wrench.

• Fully adjustable (2” – 8”) IR electronic detection sensor by means of a potentiometer.

• Automatic disconnection system after 30 seconds of continuous use.

• Heating element with a self-resettable safety cut-out. It can be switched off manually with an ON/OFF micro switch located on the electronic board.

• Aluminum centrifugal double asymmetrical inlet fan wheel.

• Fire resistant plastic UL 94-V0 fan scroll.

• UL and CSA approved

• Optional odor neutralizer tablet for a cleaner and more pleasant atmosphere in the washroom.

11 1/2” 290 mm

4” 100 mm

/2 ”2 m m material: cast iron finish: white porcelain enameled mph

ADA

mph mph material: steel finish: black epoxy

M17AB-UL

material: stainless steel AISI 304 finish: bright

M17AC-UL

material: stainless steel AISI 304 finish: satin

M17ACS-UL

ADA

ADA

ADA

M17A-UL · M17AF-UL · M17AB-UL · M17AC-UL · M17ACS-UL

Estimated drying time 10-12 seconds Total Power: 180 - 850W

Voltage 100-120 V; 208V; 220-240 V Heating Element: 500 W

Frequency 50/60 Hz Protection level IP23

Power Consumption H. Element OFF: 2.5 - 3.5 A H. Element ON: 4.8 - 7 A

Effective airflow 20 - 27 CFM

Electrical insulation Class I (ground required) Air temp (at 4” distance/77ºF) 93º - 103ºF

Motor Power 350 W Dimensions 11-1/2”x 10 5/8”W x 4” rpm 23,000 - 32,000 rpm Weight All: 8,4 Lbs

Air speed: 250 mph Noise level

M17AF-UL: 15,65 Lbs

57-65 dBA

(B)

(B)

(B)

(B)

Dimensions for M06A/AB/AC/ACS sensor operated

ADA

(B) mph material: steel finish: white epoxy

M17A-UL

M17AF-UL

Legend for symbols shown on last page of catalog

Finish/material equivalent to specified

Saniflow Corp reserves the right to make changes and/or modifications to the products and their specifications without warning or notice.

For further info please contact SANIFLOW on: Toll free: 1-877-222-9125 or visit our website at www.saniflowcorp.com Tel: +1 (305) 424 2433 Fax: +1 (305) 424 2435 · sales@saniflowcorp.com

General Description Warm air high speed hand dryer recommended for very high traffic areas.

Surface mounted ADA-compliant.

Maximum robustness and vandal-proof.

Energy efficient, it only consumes 2.8 watts per drying cycle.

Building Green Approved & offering LEED Credits.

HEPA filter medium cartridge which filters solid particles in suspension, improving air quality.

Universal voltage.

Components & Materials M17A-UL: 1/16” (1.5 mm) thick one-piece steel cover; white epoxy finish •

M17AB-UL: 1/16” (1.5 mm) thick one-piece steel cover; black epoxy finish •

M17AC-UL: 1/16” (1.5 mm) thick one-piece stainless steel cover; bright finish •

M17ACS-UL: 1/16” (1.5 mm) thick one-piece stainless steel cover; satin finish •

M17AF-UL: 3/16” (4.5 mm) thick one-piece cast iron cover, white porcelain finish •

MOTOR: High pressure class F, with self-resettable safety cut-out and adjustable speed between 23,000 and 32,000 rpm. This regulation is carried out manually by means of a potentiometer located on the electronic board to adjust the power consumption of the dryer. The motor has been configured to have a smooth start to extend its life.

ELECTRONIC DETECTION SENSOR: by infrared beam with detection distance adjustable by potentiometer between 2” and 8”. It incorporates a safety system that detects any fixed target and makes hand dryer stop automatically in case a fixed object is placed in front of the sensor. In addition it has an automatic disconnection system of the unit after the 30 seconds of continuous use of the dryer.

500 W HEATING ELEMENT: with a self-resettable safety cut-out. It can be switched off manually with an ON/OFF micro switch located on the electronic board, allowing to regulate the power consumption of the hand dryer.

made of aluminum, it incorporates acoustic dampening elements (silent-blocks) •BASE PLATE: for the suppression of mechanical vibrations.

AN SCROLL: made with Polyamide 6 (PA 6) incorporating a flame retardant additive (UL 94 V0) that Fincreases the resistance to plastic ignition and once ignited reduces the rate of flame propagation.

HEPA FILTER MEDIUM CARTRIDGE: Filters solid particles in suspension, significantly improving air quality. This filter traps micro particles in the air such as pollen, dust mites, fungi, tobacco smoke, etc..

ODOR NEUTRALIZER TABLET: an optional odor neutralizer tablet for a cleaner and more pleasant atmosphere in the bathroom is available (Code RCPOM14).

WALL FIXING ELEMENTS: stainless steel screws for brick wall with their corresponding plastic plugs are provided with the hand dryer.

Technical Specifications

Voltage - 100-120V; 208V; 220-240V Total power - 180- 850 W

Frequency - 50/ 60 Hz Motor Power - 350 W

Insulation - Grounding required (Class I) Heating element: 0 or 500W

Dimensions M17A/AC/AB/ACS 10 1/2”H x 11 1/2”W x 4”D M17AF 10-5/8”H x 11-5/8”W x 4”D

Consumption H. Element OFF: 2.5 – 3.5A H. Element ON: 4.8 – 7A

Weight - M17A/AC/AB/ACS - 8.4 Lbs.

M17AF - 15,65 Lbs.

r.p.m. - 23,000-32,000 rpm

Effective airflow - 20-27 CFM Air temperature – (at 4” distance/ T amb. 77 ºF) 93-109 ºF

Max air velocity - 250 mph/ 22,000 LFM Drying time - 10 – 12 sec

Protection level - IP23 Noise level (at 79”) - 57 – 65 dBA

M17A-UL

code material steel finish white epoxy

M17ACS-UL

code material stainless steel

AISI 304

finish satin

DATA SHEET

M17A-UL / M17AB-UL / M17AC-UL / M17ACS-UL / M17AF-UL

Please mark the selected item

Hand Dryer Technology At the Leading Edge

M17AB-UL

code material steel finish black epoxy

M17AC-UL

code material stainless steel

AISI 304

finish bright

Operation Place hands under the air outflow valve. The dryer will start automatically, and go on with no interruption as long as the hands are kept in the detection range of the sensor. The appliance will stop 2 seconds after the hands are removed from the airflow.

M17AF-UL

code material cast iron finish white porcelain enamelled coating

Saniflow Corp reserves the right to make changes and/or modifications to the products and their specifications without warning or notice.

For further info please contact SANIFLOW on: Toll free: 1-877-222-9125 or visit our website at www.saniflowcorp.com Tel: +1 (305) 424 2433 Fax: +1 (305) 424 2435 · sales@saniflowcorp.com

Installation Verify all rough-in dimensions prior to installation. Hand dryers require a dedicated circuit and must be properly grounded.AGFCI (Ground fault circuit interrupter) is recommended..One side of dryer should be mounted to a stud.

Certificates & Qualifications Unit shall be UL and CSA approved, according to UL 499; CSA C22.2 Standards and Building Green Approved. UL and CSA approved according to UL 499 and CSA C22.2 Standards.

Nº dryers to be fitted

▪ In toilet areas with a normal frequency of use and only one wash-basin: 1 dryer.

▪ In toilet areas with a normal frequency of use and more than one wash-basin: 1 dryer for each

2-3 wash-basins.

▪ 1 row of 4 wash basins: 2 dryers; 1 row of 6 wash basins: 3 dryers; 1 row of 8 wash basins: 4 dryers.

▪ In toilet areas with high traffic and more than one wash-basin: 2 dryers for each 3 wash-basins.

▪ 1 row of 4 wash basins: 3 dryers; 1 row of 6 wash basins: 4 dryers; 1 row of 8 wash basins: 5 dryers.Ideal location Between the wash-basin and exit. It is not recommended to install dryer between wash-basins, next to urinals, lavatories and showers. If installing automatic dryers over marble surface or ledge, the minimum distance from the dryer to the ledge must be 15-3/4”. It is recommended that hand dryers be distributed throughout the washroom area to avoid overcrowding.

Guide Specification Surface-mounted ADA compliant hand dryer shall have a 1/16” thick steel cover with white epoxy finish (M17A-UL), or a 1/16” thick steel cover with black finish (M17AB-UL), or a 1/16” thick stainless steel cover with bright finish (M17AC-UL), or a 1/16” thick stainless steel cover with satin finish (M17ACS-UL), or a 3/16” thick cast iron with white porcelain enamelled coating (M17AF-UL).

Hand dryer shall include aluminum base plate 1/8” thick, infrared sensor adjustable (2” to 8”) via potentiometer , universal brush motor fully adjustable (23,000-32,000 RPM) via potentiometer as well and HEPA filter medium cartridge which filters solid particles in suspension, significantly improving air quality. Dryer shall operate at 57-65 dBA while delivering 20–27 CFM of air at 109 ºF (42ºC) and 250 mph as maximum air velocity (Max – 22,000 LFM) during user controlled drying cycle. Dryer shall have a total power of 180 - 850 W with a consumption of 2.5 – 7 A. Heating element made of Ni-Cr and with a self-resettable safety cut-out. It can be switched off manually “ON / OFF” micro-switch located on the electronic board, allowing to regulate the power consumption of the hand dryer. In case of motor failure the heating element is immediately switched off automatically.Unit shall be UL and CSA approved, according to UL 499, CSA C22.2 standards, and Building Green Approved.

Overall dimensions:

M17A, M17AB, M17AC, M17ACS: 10 1/2”H x 11 1/2”W x 4”D (270mm x 290 mm x 100 mm) M17AF: 10-5/8”H x 11-5/8”W x 4”D (270 mm x 295 mm x 102 mm)

MOUNTING

9 1/4” (235mm)

7 3/4” (197mm)

Ø 1/4” (7mm)

Ø 1” (25mm)

See table for recommended z mounting height x y

Serial mounting

1/

2” (1 m m

24” (610 mm)

24” (610 mm)

14” (360 mm)

11 1/2” (292mm)

4” (102mm) 9 1/4”

(235mm)

3/

4”

1/ 2”

(1 m m

(2 m m

Job:

Model number:

Variations:

Architect / Engineer:

Contractor:

Customer / Wholesaler:

City / State / Country:

Date:

Quantity:

M17A-UL / M17AB-UL /

M17AC-UL / M17ACS-UL

Recommended heights from floor

Male Female Child Disabled x To top of machine 56” / 142 cm 54” / 137 cm 46” / 117 cm 48” / 122 cm y To mounting bracket screw 55” / 140 cm 53” / 135 cm 45” / 115 cm 47” / 120 cm z To sensor top 46” / 117 cm 44” / 112 cm 36” / 92 cm 38” / 97 cm

M17AF-UL

The new generation of SPEEDflow ® hand dryers is quicker, more hygienic, more comfortable, quieter and more energy-efficient, providing a unique experience in the hand drying field.

The new SPEEDFLOW® comes as standard with a cartridge that holds an HEPA filter medium that filters suspended solid particles (pollen, dust mites, cigarette smoke, etc.), notably improving the air quality.

Furthermore, this cartridge also contains and activated carbon filtering medium that neutralizes odours and absorbs fumes and gases, helping avoid bad odours.

Air quality and noise pollution improvement thanks to its new filter and inner design

LOW CONSUMPTION COMFORT

HYGIENE SAFETY

Minimum consumption Between 0.6 and

2.8 W/h per drying

cycle and 0.4 W in stand-by. One of the lowest in the market.

Automatic activation The user does not need to touch the hand dryer, which helps prevent cross-contamination, improving hygiene and asepsis.

Adjustable motor speed Adjustable energy consumption, noise level and drying time, consequently.

HEPA filter medium Cleans the air stopping the particles of dirt, dust, bacteria, pollen, etc. Fresh and particle-free air.

Heating element with ON/OFF micro-switch Placed in the electronic circuit board, makes it possible to activate/ deactivate the heating element.

Odor neutralizer tablet For a more pleasant atmosphere in the washroom.

Fixed-target detection If a static object is detected by the sensor, the hand dryer automatically stops after 3-5 seconds as a security measure.

Automatic safety cut-out After 30“ of continuous use, the hand dryer switches off automatically.

Vandal-proof locking system The metal casing is fixed to the aluminium base plate by means of 2 vandal-proof screws.

CONSUMPTION IN WATTS HOUR

PER DRYING CYCLE

Heating element Energy saving (only 500W), to ensure maximum comfort when drying hands.

Quiet. 57 dBA Thanks to the acoustic dampening elements used and a better-balanced mechanically motor, among others.

Air curtain drying A well-designed air outlet blows air caressing and drying hands thanks to a pleasant air curtain.

The new SPEEDFLOW® is much quieter thanks to:

• The acoustic dampening elements used for fixing the nozzle to the base plate and also in the motor bracket.

• A inner nozzle design which minimizes the pressure drop and the turbulences, reducing the noise level consequently.

• The air outlet geometry minimizing unwanted acoustic effects .

• A motor with a built-in fan, better-balanced mechanically, reducing the vibrations transmitted to its supports

110 South Union St., Suite 100, Alexandria, VA 22314

SUBSTITUTION

REQUEST

(During the Bidding/Negotiating Stage)

Proposed Substitution:

Manufacturer:

Trade Name:

Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.

The Undersigned certifies:

• Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

• Same warranty will be furnished for proposed substitution as for specified product.

• Same maintenance service and source of replacement parts, as applicable,is available.

• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

• Proposed substitution does not affect dimensions and functional clearances.

• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution.

Submitted by:

Signed by:

Firm:

Address:

Telephone:

Hellen Olivares

Saniflow Corp

3325 NW 70th Ave, Miami, FL, 33122

305-424-2433 x. 2022

Saniflow Corp. Address:3325 NW 70th Ave ., Miami FL, 33122 Saniflow, a Mediclinics Company

Babymedi + Recessed Kit

Description: Public-Use Washroom Accessories

Paragraph: 2.2

Substitution Request Number:

From: Saniflow Corp. / Attn: Hellen Olivares

Date: 5/22/2026

A/E Project Number: 20251010

Project: Hartwick Pines State Park - Visitor Center Renovation

To: Integrated Architecture

Re: Substitution/ Equal

Specification Title: Toilet, Bath, and Laundry Accessories

� Substitution approved as noted - Make submittal in accordance with Specification Section 01 25 00 Substitution Procedures.

� Substitution approved - Make submittal in accordance with Specification Section 01 25 00 Substitution Procedures.

� Substitution Request received too late - Use specified materials.

� Substitution rejected - Use specified materials.

A/E’s REVIEW AND ACTION

Section: 102800 Page: 2

Hellen Olivares

Phone: 305-424-2433

Model No.: CP0016HCS-ASTM + KT0016HCS

3612 State Park Dr, Grayling, MI, 49738 (Crawford County)

5/27/26

Comparison BabyMedi® Koala Kare Item No. CP0016HCS- ASTM KB310-SSRE

Materials Bacteria-resistant Polypropylene Plastic and Stainless Steel exterior Grey injection-molded polypropylene and Stainless Steel exterior

Antimicrobial Biocote® additive, based on ion silver technology embedded into surface Microban additive into the bed surface

Dimensions 33 ⅞” W x 18 ⅞” H Depth while open: 22 ½” Closed: 3 ⅞”

41 5/16” W x 26 7/32″ H Depth while open: 17 13/32”

Closed: 2 23/32”

Weight 35.3 lb 80 lbs

Finshes Black Stainless Steel Cover Finish Black �inished stainless steel

Liner dispenser capacity 80 units 50 units

Maximum support 220lbs 200lbs

Price Comparison $750 $1,319.59

Features 2 Bag hooks Nylon safety straps

1 Bag hook, Nylon safety straps and dual liner cavity

ADA surface mounted Yes Yes

Warranty 5-year limited warranty 5-year limited warranty

Certi�ications ASTM F2285-04, EN 12221-1, EN 12221-2 ASTM F2285-04(16), ANSI Z535.4, EN 12221:2008+A1: 2013.

Item No. Recessed Kit- KT0016HCS

Materials Wall Box - AISI 304 stainless steel with satin �inish Frame - AISI 304 stainless steel with a satin �inish

Dimensions L:36 1/4” x W:4” x H:27 1/8”

Thickness Wall Box - 0.031” Frame - 0.031”

Wall Hole Dimensions L:34 41/64” x W:3 57/64” x 25 33/64”

Weight 14 Lbs.

Screws Not Included

Price $495

BabyMedi® changing stations offer a very high level of safety and cleanliness being the ideal solution for public spaces with models suitable for high traffic facilities providing high strength and durability.

Provide stain stainless steel finish at unit and in recessed box.

Saniflow Corp reserves the right to make changes and/or modifications to the products and their specifications without warning or notice.

For further info please contact SANIFLOW on: Toll free: 1-877-222-9125 or visit our website at www.saniflowcorp.com Tel: +1 (305) 424 2433 Fax: +1 (305) 424 2435 · sales@saniflowcorp.com

General Description Surface-mounted baby changing stations made of bacterial-resistant polypropylene and with stainless steel AISI 304 exterior (CP0016HCS-ASTM and CP0016HCSB-ASTM). High level of safety and cleanliness.

Models offer great strength and durability, suitable for high traffic facilities.

Trendy and stylish design.

Biocote ® antimicrobial additive into its own surface.

Includes a pair of bag hooks to keep personal belongings close and at hand.

Fully comply with the American standard ASTM F2285-04 and the European EN 12221-1 and EN 12221-2 standards.

Components & Materials CP0016H: surface-mounted baby changing station made of polypropylene in white finish.

CP0016HCS: surface-mounted baby changing station made of polypropylene and with a stainless steel AISI 304 exterior, in satin finish.

CP0016HCSB: surface-mounted baby changing station made of polypropylene and with a stainless steel AISI 304 exterior, in black finish.

BED: with approximately 295 in² contoured changing surface area is made of polypropylene in white finish Biocote ® antimicrobial additive embedded into its surface, promoting easy cleaning and reducing the growth of odor-causing and staining microbes.

LINER DISPENSER: is made of polypropylene and holds approximately 80 bed liners, minimizing operator refills and discouraging potential vandalism.

OPEN/CLOSE MECHANISM: concealed from the user´s view, it consists of a pair of reinforced hinges and a pneumatic cylinder, ensuring high durability and a smooth opening and closing of the baby changing station.

MOUNTING CHASSIS: made of steel with a cataphoresis treatment. The corresponding mounting hardware is supplied, making the unit installation to the wall easy.

▪ FRONTAL CHASSIS: (CP0016HCS / CP0016HCSB) made of one-piece AISI stainless steel, 1/32” thick, fixed to the bottom of the bed by means of 4 bolts and 4 nuts, always concealed from the user´s view, without joints or edges to ensure the user´s safety, a better cleaning and a seamless blending with other satin finish accessories in the washroom.

Technical Specifications

Dimensions L:33 7/8” x W:3 7/8” (closed) / 22 1/2” (open) x H:18 7/8”

Weight (empty) 2 lb (CP0016H) 3 lb (CP0016HCS / CP0016HCSB)

Liner dispenser capacity 80 units

31 1/2” at lowest point Recommended installation height code

CP0016H-ASTM

material polypropylene finish white code

CP0016HCS-ASTM

material polypropylene / stainless steel finish white / satin

DATA SHEET

CP0016H-ASTM / CP0016HCS-ASTM / CP0016HCSB-ASTM

Please mark the selected item

Hand Dryer Technology At the Leading Edge

Operation

Open the BabyMedi® baby changing station. Place the baby on the centre of the bed and change your baby´s diapers. Close the BabyMedi® station.

Under no circumstance should the baby be left unattended at any time on top of the baby changing station in order to avoid injury from falling or slipping.

CP0016HCSB-ASTM

code white / blackmaterial

BabyMedi® changing stations offer a very high level of safety and cleanlines

Saniflow Corp reserves the right to make changes and/or modifications to the products and their specifications without warning or notice.

For further info please contact SANIFLOW on: Toll free: 1-877-222-9125 or visit our website at www.saniflowcorp.com Tel: +1 (305) 424 2433 Fax: +1 (305) 424 2435 · sales@saniflowcorp.com

Installation According to the installation and safety instructions manual supplied with the unit.

IMPORTANT: in order to ensure BabyMedi is properly installated it is recommended that a qualified person carries out the installation of the unit. The unit must be properly installed on a wall that is able to sustain a considerable weight and can accommodate the supplied installation hardware.

Certificates & Qualifications Unit shall be ASTM aprproved, according F2285-04 standard and GS according EN 12221-1 and EN 12221-2 standards.

Ideal location Public spaces such as, shopping centers, airports, public buildings, childcare centers, etc. Models suitable for high traffic facilities with high strength and durability.

IMPORTANT: the Congress of the United has taken a further step towards gender equality by implementing law 114-235 (10/07/2016). By this law, the American Government states that restrooms, both for men and women, in public buildings all around the country, must have diaper changing facilities in place.

Guide specification Surface-mounted Surface-mounted baby changing stations made of bacterial-resistant polypropylene (CP0016H, CP0016HCS and CP0016HCSB) and with stainless steel AISI 304 exterior (CP0016HCS and CP0016HCSB).

BabyMedi® changing stations offer a very high level of safety and cleanliness being the ideal solution for public spaces such as, shopping centers, airports, public buildings, childcare centers, etc. Models are suitable for high traffic facilities where great strength and durability is needed.

Their trendy and stylish design, allow these baby changing stations to blend into any space perfectly.

Biocote® antimicrobial additive, based on ion silver technology, is embedded into the surface, promoting an easy cleaning and reducing the growth of odor causing and staining microbes.

BabyMedi® baby changing stations are supplied with child protection straps made of nylon assembled.

A pair of bag hooks (one at the right side and the other one at the left) help to keep personal belongings close and at hand.

BabyMedi® units fully compliant with the American standard ASTM F2285-04 and the European EN 12221-1 and EN 12221-2 standards that require baby changing stations be able to support a 110 lb static load test during one hour. Moreover, units tested in our own laboratories have withstood loads over 220 lb.

Overall dimensions:

L:33 7/8” x W:3 7/8” (closed)/ 22 1/2” (open) x H:18 7/8”

MOUNTING

Job:

Model number:

Variations:

Architect / Engineer:

Contractor:

Customer / Wholesaler:

City / State / Country:

Date:

Quantity:

y To mounting brackets 16 3/8” (415 mm) 16 3/8” (415mm) 12 13/32 “(315mm)

CP0016H-ASTM / CP0016HCS-ASTM /

CP0016HCSB-ASTM

polypropylene / stainless steel finish

Recommended installation height (handicapped)

27 1/2 at lowest point

Saniflow Corp reserves the right to make changes and/or modifications to the products and their specifications without warning or notice.

For further info please contact SANIFLOW on: Toll free: 1-877-222-9125 or visit our website at www.saniflowcorp.com Tel: +1 (305) 424 2433 Fax: +1 (305) 424 2435 · sales@saniflowcorp.com

General Description

▪ Kit to recess the BabyMedi horizontal baby changing station to the wall.

▪ This kit to recess the BabyMedi horizontal baby changing station allows the changing table to be completely flush with the wall once it is closed, not taking up unnecessary space and thus allowing the creation of more open spaces free of obstacles.

▪ Possibility of combining finishes between the kit for recess and the baby changing station.

▪ Maximum robustness and vandal-proof design.

▪ Excellent integration and aesthetic level

Components & Materials

• KT0016HCS: kit for recessing into the wall the BabyMedi horizontal baby changing stations CP0016HCS or CP0016HCSB by Mediclinics. Made of AISI 304 stainless steel with a satin finish.

• KT0016HCSB: kit for recessing into the wall the BabyMedi horizontal baby changing stations CP0016HCS or CP0016HCSB by Mediclinics. Made of AISI 304 stainless steel with a matte black finish.

KT0016HCS

code material AISI 304 stainess steel finish satin

Please mark the selected item

• WALL BOX: 0.031” thick, made of AISI 304 stainless steel with satin finish (KT0016HCS) or matt black finish (KT0016HCSB), with 4 Ø 0.3” side holes to fix the changing table to the hole in the wall.

•Warning: Before installation please refer to the supplied installation manual as to ensure the unit willFRAME: integrated into the same wall box, 0.031” thick, made of AISI 304 stainless steel with a satin function properly and safely, it must be installed in accordance with these instructions. finish (KT0016HCS) or a matte black finish (KT0016HCSB).

• SCREWS: for wall mounting are not included. It is recommended the use of stainless steel screws and specific for the type of wall where the installation will be made.

Technical Specifications KT0016HCSB Dimensions

L:36 1/4” x W:4” x H:27 1/8” code material AISI 304 stainess steel

Hand Dryer Technology At the Leading Edge

DATA SHEET

KT0016HCS / KT0016HCSB

Weight: 27.12 Lbs. (CP0016H) / 35.3 Lbs. (CP0016HCS and CP0016HCSB)

Recommended heights from floor

Disabled Male Female

31 1/2” (800 mm) 31 1/2” (800 mm) 27 1/2” (700 mm) x To bottom of unit

Saniflow Corp reserves the right to make changes and/or modifications to the products and their specifications without warning or notice.

For further info please contact SANIFLOW on: Toll free: 1-877-222-9125 or visit our website at www.saniflowcorp.com Tel: +1 (305) 424 2433 Fax: +1 (305) 424 2435 · sales@saniflowcorp.com

Installation According to the installation and safety instructions manual supplied with the unit.

IMPORTANT: in order to ensure recessed BabyMedi is properly installated it is recommended that a qualified person carries out the installation of the unit. The unit must be properly installed on a wall that is able to sustain a considerable weight and can accommodate the supplied installation hardware.

Ideal location Public spaces such as, shopping centers, airports, public buildings, childcare centers, etc.

Models suitable for high traffic facilities with high strength and durability.

IMPORTANT: the Congress of the United has taken a further step towards gender equality by implementing law 114-235 (10/07/2016). By this law, the American Government states that restrooms, both for men and women, in public buildings all around the country, must have diaper changing facilities in place.

Guide specification

DIMENSIONS

Job: Architect / Engineer:

Model number: Contractor: Date:

Variations: Customer / Wholesaler:

City / State / Country:

Quantity:

KT0016HCS / KT0016HCSB

finish matte black

L:34 41/64” x W:3 57/64” x

25 33/64”

0.031”

Wall hole dimensions

Wall box thickness

Frame thickness 0.031”

Net weight 14 Lbs.

Mounting

Fix the kit with the most suitable screws for the type of wall, through the holes on the side of the mounting chassis, to the wall, at the points indicated with an “S” in the following figure and always following, step by step. step, the mounting instructions you will find in the “Installation and Assembly Manual” provided with the unit..

When installing the recessed kit, keep in mind that the bottom of the changing table must be at a height of approximately 31 1/2” from the ground.

Kit to recess the BabyMedi horizontal baby changing station to the wall.This kit to recess the BabyMedi horizontal baby changing station allows the changing table to be completely flush with the wall once it is closed, not taking up unnecessary space and thus allowing the creation of more open spaces free of obstacles.

Possibility of combining finishes between the kit for recess and the baby changing station.

Maximum robustness and vandal-proof design.

Excellent integration and aesthetic level

Overall dimensions:

L:36 1/4” x W:4” x H:27 1/4””

Net weight: 14 Lbs.

260529_Hartwick DTMB0414 Construction Addendum 1 BID
26054_AG_PreBID_RED_2026-0521
260527_Hartwick PreBid Sign In
SPEEDFLOW PLUS M17 VS DYSON AIRBLADE V STAINLESS STEEL (70)
STAINLESS STEEL RECESSED BABYMEDI VS KB310-SSRE 1 (4)

File details come from the government source that posted it. Updated .