Addendum 1 25061.pdf
PDF 7 MB Posted
- Solicitation number
- RFP 171 250000002458 3
- Issued by
- Delta County, Edmore Village, Michigan
About this file
This is Addendum No. 1 to a Request for Proposal (RFP) issued by the Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division for professional services at Bay Pines Center in Escanaba, Michigan. The project involves design and construction services for generator, HVAC, and fire suppression system upgrades with an associated construction budget of $3.3 million. The scope of work has been expanded to include: smoke detector review and compliance upgrades integrated into the new fire suppression system; replacement of existing furniture in all resident bedrooms with detention-grade anti-ligature furniture and polished/sealed concrete flooring; wall painting; window replacements in specified bedrooms and common areas using low-VOC materials; evaluation of up to three PA system options with the associated cost and analysis included as Phase 400 scope; review and evaluation of existing generators for potential incorporation; and ATS (automatic transfer switch) replacement as part of the generator upgrade. The proposal due date is June 26, 2025, and a pre-proposal meeting/walkthrough was held with an attendance list provided as an attachment.
The RFP specifies that professional services consultants (PSCs) shall base their proposals on the $3.3 million construction budget and assume minimal interruptions to the facility's fire system, with the option to remove and reinstall ceilings if necessary to achieve operational continuity. The facility prioritizes maintaining PA system functionality for front office announcements and requests evaluation of paging options including a reference estimate from Prudential Alarm valued at $116,753.30 for information purposes only. Technical documentation provided includes the Ahern fire inspection report dated January 8, 2025, which identified deficiencies including three non-functional spot-type smoke detectors (1D003, 1D011, and 1D085) requiring replacement due to age and intermittent troubles, along with electrical one-line diagrams, current architectural CADD files, floor plan markups indicating painting and flooring upgrade locations, and window replacement locations. The selected PSC will receive updated architectural CADD files and must review and confirm the accuracy of all provided files.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1DTMB-0414 RFP (Rev 2/22)
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
State Facilities Administration Design and Construction Division
REQUEST FOR PROPOSAL
ADDENDUM NO. 1
This form identifies an Addendum to a Request for Proposal for Professional Services, and incorporates interpretations or clarifications, modifications, and other information into the Request for Proposals.
Addenda will be numbered by the Project Director and distributed through SIGMA Vendor VSS as an attachment.
TO:
ALL PROPOSERS
DATE ISSUED
6/18/25
PROJECT NAME
Bay Pines - Generator, HVAC, Fire Suppression
FILE NUMBER
491/25061.JBB
PROJECT DIRECTOR
Jeff Barsch
PROPOSAL DUE DATE:
6/26/2025
ADDENDUM ITEMS: (attach additional sheets and drawings if required)
1) Pre-Proposal Meeting attendance of firms eligible to submit a proposal is attached.
2) PSC’s shall assume a construction Budget of 3.3 Million for this project.
3) PSC’s shall add the following scope to the project-PSC’s shall review the existing smoke detectors for operation and compliance and shall incorporate upgrades or replacements into the new fire suppression system as required. The Ahern inspection report is included and the BFS fire inspection report from Bays Pines DCWL License renewal will be provided to the selected PSC if unavailable prior to the proposal deadline.
4) PSC’s shall add the following scope to the project-All resident bedrooms will have the existing furniture replaced with new detention grade anti ligature furniture some of the furniture will be purchased by the owner and then coordinated during the project for installation. The existing floors will be finished with polished/sealed concrete in each resident’s room and the walls shall be painted.
In addition several common area floors will be revised to polished concrete as well. Windows in the bedrooms as well as some common are windows will also be replaced see attachment Bay Pines Windows for locations. Low VOC materials will be required as only one room is anticipated to be vacated/worked on at a time. Additionally floors and walls in the common spaces listed on the attached markup will also be painted and revised to sealed polished concrete. See the attachment “Bay Pines Flooring” for locations.
5) The facility would like minimal interruptions to the fire system and will consider having ceiling removed and reinstalled if that helps achieve that goal.
6) The facility would like to have the PA system functional for announcements from the front office as reviewed on the walkthrough. The facility would like up to three options to be researched for consideration as the basis of design for the PA system. Please add phase 400 scope for time spent evaluating paging options. The paging system estimate from Prudential Alarm is provided for information only.
7) Please add the time spent reviewing/evaluating the potential existing generators for possible incorporation as Phase 400 scope.
8) ATS replacement will need to be included as part of the generator/replacement upgrade scope. The electrical one line for the site is included.
9) The most up to date Architectural CADD Files will be provided to the selected PSC along with any additional CADD files the facility has on record. A pdf of the most current architectural layout is provided as reference. The selected PSC’s will need to review and confirm accuracy of any files http://www.buy4michigan.com/ provided.
Attachments
1) Pre-Proposal Meeting/Walkthrough Attendance List
2) Ahern Report
3) Floor Plan Mark up with desired painting/flooring upgrades in addition to the residents bedrooms.
4) Floor Plan Mark up With Desired Windows to be replaced.
5) Informational pricing for a PA system the facility received which does not entirely meet the facility needs.
6) Electrical One Line Diagram
7) Current Up To Date Floor Plan that will be available by CADD.
APPROVED BY:
PROJECT DIRECTOR DATE 6/18/2025
Fire Alarm Inspection
Annual
Inspection Information
Work Order: 1759693
Agreement: 54523
Inspection Start Date: 01/07/2025
Customer PO:
Inspection Location
Bay Pines Center
MI Family Independent Agency, 2425 North 30th Street
Escanaba, MI 49829-9203
CID: 6707 LOC ID: 001
Contact Information
James Sanville
Phone: (906) 399-6109 sanvillej@michigan.gov
Inspection Contractor
J. F. Ahern Co. / Ahern Fire Protection
855 Morris St, P.O. Box 1316
Fond du Lac, WI 54936-1316
(920) 921-9020
AhernService@jfahern.com
Inspection Technician Info
Technician: Daniel Betz
Technician License:
Inspection Type: Annual
Codes: NFPA 72-2010
Inspection End Date: 01/08/2025
Equipment Summary
Annunciators Total 1
Passed 1
Failed 0
Heat Detect - Non-Restorable Total 1
Passed 1
Failed 0
SH Manual Alarm - Release Total 1
Passed 1
Failed 0
Smoke Detection - Spot Type Total 1
Passed 0
Failed 1
Fire Alarm Control Panel Total 1
Passed 1
Failed 0
Notification Appliances Total 1
Passed 1
Failed 0
Smoke Detection - Duct Type Total 1
Passed 1
Failed 0
Deficiency Details FA008 - Smoke Detection - Spot Type System ID- Photo Question ID: 10 Task: Annual Location:
Question: Did the detector(s) pass the functional test? No
Tech Notes: 1D003, 1D011 and 1D085 did not pass functional test. Ahern to provide quote for replacement. Due to age of detectors and continuous intermittent troubles it is recommended that detectors be updated from obsolete devices.
Deficiency Authority NFPA 72 Section: Table 14.4.2.2 14g 1
Smoke detectors/smoke alarms shall be tested in place to ensure smoke entry into the sensing chamber and an alarm response. Testing with smoke or listed aerosol, acceptable to the manufacturer of the aerosol or the manufacturer of the smoke detector/smoke alarm and identified in their published instructions, shall be permitted as acceptable test methods. Other methods listed in the manufacturer's published instructions that ensure smoke entry from the protected area, through the vents, into the sensing chamber shall be permitted. Any of the following tests shall be performed to ensure that each smoke detector is within its listed and marked sensitivity range: (1)Calibrated test method (2)Manufacturer's calibrated sensitivity test instrument (3)Listed control equipment arranged for the purpose (4)Smoke detector/control unit arrangement whereby the detector causes a signal at the control unit when its sensitivity is outside its listed sensitivity range (5)Oher calibrated sensitivity test method approved by the AHJ.
TECHNICIAN COMMENTS:
None
Ahern will be contacting you shortly to discuss how we may help you create an action plan to correct deficiencies identified in this inspection.
Inspection Contractor: J. F. Ahern Co. / Ahern Fire Protection
855 Morris St, P.O. Box 1316
Fond du Lac, WI 54936-1316
This inspection report is expressly subject to the terms and conditions of sale located at J. F. Ahern Co. Terms and Conditions which are incorporated by reference as if fully set forth herein. By accepting this inspection report you are deemed to have read, understood and accepted the electronic terms and conditions of sale.
This document is the property of the inspecting entity. Copyright J. F. Ahern Co./Ahern Fire Protection.
REPRODUCTION IN ANY FORM VIOLATES COPYRIGHT.
Building Owner or Authorized Representative Technician
Signature: Signature:
Name: James Sanville Name: Daniel Betz
License #:
Customer Signature Date: 01/08/2025 Inspection End
Date: 01/08/2025
CLARIFICATIONS:
Any comments or findings in this inspection report are not in any way to be considered a fire protection engineering review.
https://www.jfahern.com/general-terms-and-conditions-sale
Equipment Details Annunciators FA002 - SH Fire Alarm System
Qty: 1 Eq ID: FA003
Annunciator Type Location In Building
Manufacturer ID Model ID
Network Interface
PODS
Firelite
Question Result
Did the Annunciator operate properly and identify events correctly? Yes
If applicable, did the Annunciator still operate under a fault condition? Yes
Did annunciator pass visual inspection? Yes
Bldg/Owner Questions FA FA001 - Bldg/Owner Questions FA
Qty: 1 Eq ID: FA001
Approving agency (municipality)?
Approving agency phone number?
Delta County 970-874-2015
Question Result
Monitoring Company Name? Not monitored
Monitoring company telephone number (XXX.XXX.XXXX)? 000.000.0000
Monitoring account reference number? 0
Monitoring Phone Line #1 (XXX.XXX.XXXX)? 000.000.0000
Monitoring Phone Line #2 (XXX.XXX.XXXX)? 000.000.0000
Has the system remained in service without modification since the last inspection? Yes
Was the system free of actuation of devices, alarms, or fires since the last inspection? Yes
Were all systems left in operational condition, actuating devices reset and in place, and pictures taken? Yes
Date of last system service? 2025-01-07
Sensitivity test performed? If performed/applicable, see addendum document. Yes
Fire Alarm Control Panel FA002 - SH Fire Alarm System
Qty: 1 Eq ID: FA005
# of Annunciators Customer System ID
Dedicated Eng Based Gen Emerg Ctrl Function Types
Gen Fuel Storage Loc Interfaced Equip Types
Location In Building Manufacturer ID
Model ID Panel Circuit Style
Software Revision Number
4.0000
No None None Annunciator Server rm by cafeteria Firelite
MS-9200UDLS
Class A
Question Result
Were all building occupants and facilities receiving alarm, supervisory, or trouble signals notified prior to testing? Yes
Did the panel functions comply with the desired sequence of operations? Yes
Did interface equipment pass visual inspection? Yes
Are batteries free of corrosion and leakage and all connections tight? Yes
Battery type? Sealed Lead Acid
Record battery #1 voltage. 13.65 Volt
Record battery #1 load test results. 18
Record battery #2 voltage. 13.57 Volt
Record battery #2 load test results 18
Did batteries pass charger test, discharge test, and load voltage test? Yes
Did system operate properly on standby power? Yes
Were all building occupants and facilities receiving alarm, supervisory, or trouble signals notified at the conclusion of testing? Yes
Date and time system restored to normal operation (mm/dd/yyyy hh:mi am/pm). 01/07/2025
Are all lamps and LED's operational? Yes
Were all alarm, supervisory, and trouble signals received? Yes
Were all alarm, supervisory, and trouble signals restored? Yes
Are all fuses intact and rated properly? Yes
Does the open circuit and ground fault monitoring function properly and pass visual check? Yes
Do all interfaced equipment circuits operate properly? Yes
Did disconnect switch function, create trouble at panel, and pass visual inspection? Yes
Did all emergency control functions operate properly? Yes
Location of primary power supply? Left of FACP
Location of primary power disconnect (breaker #)? 8
Calculated amp hours of secondary power supply? 18 Amp-Hours
Secondary power supply calculated duration? 24
Record input voltage. 120 Volt
Overcurrent protection type? Breaker
Record breaker amp size. 15
Record charger voltage. 27.23 Volt
Date of last software or configuration revision? N/A
Alarm verification feature status? N/A
Record battery date. 2022-10-25
Heat Detect - Non-Restorable FA002 - SH Fire Alarm System
Qty: 5 Eq ID: FA006
Location In Building Manufacturer ID
Model ID Protected Area
Temperature Rating
Chemtronics kitchen 135.0000
Question Result
Did all devices pass visual inspection? Yes
Have any detectors been in service more than 15 years? No
Has the circuit integrity been verified at the EOL? Yes
Notification Appliances FA002 - SH Fire Alarm System
Qty: 15 Eq ID: FA004
Location In Building Manufacturer ID
Number of Circuits Type of Device
System Sensor
Horn-Strobe
Question Result
Did all devices pass visual inspection? Yes
Did all devices operate properly when tested? Yes
Do device candela ratings, layout, and location match the approved drawings if available? Drawings not available
If occupancy or conditions have changed, were sound pressure levels tested to confirm they conform with occupancy types and ambient sounds? N/A
SH Manual Alarm - Release FA002 - SH Fire Alarm System
Qty: 15 Eq ID: FA007
Location In Building Manufacturer ID
Firelite
Question Result
Did all devices pass visual inspection? Yes
Did the manual fire alarm/releasing stations pass operational test? Yes
Smoke Detection - Duct Type FA002 - SH Fire Alarm System
Qty: 16 Eq ID: FA011
Location In Building Manufacturer ID
Model ID Type
System Sensor
DH100ACDC
Photo
Question Result
Did the Detector(s) pass functional test? Yes
Proper Pressure Differential and Airflow Present if Tested? N/A
Date of last sensitivity test? 2025-01-07
Smoke Detection - Spot Type FA008 - Smoke Detection - Spot Type
Qty: 63 Eq ID: FA008
Detector Type Location In Building
Manufacturer ID
Photo
System Sensor
Question Result
Did the detector(s) pass the functional test? No DEF
Date of last sensitivity test? 2025-01-07
Smoke detector passed visual inspection? Yes user7 Rectangle
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
BarschJ Text Box Flooring Upgrade Locations user7 Rectangle
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval sanvillej Oval sanvillej Oval sanvillej Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval
Bay Pines Facility Oval sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line sanvillej Line
BarschJ Text Box Windows to Be Replaced All Residents Rooms to be Painted. All Furniture replaced in bedrooms as coordinated with owner.
ESTIMATE
Services qty unit price amount
Update Audio System 1.0 $47,500.00 $47,500.00 Prudential team to update outdated Audio system. There will be two master stations, controlling different areas of the facility. The stations will have 2 way audio capability, only to initiated by security. Patients can not interact on their own. The system is live audio only, no video and no recording. Exact partitions to be confirmed with site, the current plan is for station 1 to control D Pod and Swing pod Prudential will refer to as "side 1" and the other area to be A Pod, B Pod and swing Pod, prudential will refer to as "side 2"
All existing infrastructure to be replaced. All devices to be replaced and discarded. Prudential will use existing wire paths and conduits. On Site facilities director will show Prudential where these paths are located.
There will be a total of 33 in unit audio stations, and 2 master stations for audio controls. The exact split between Side 1 and Side 2 will be confirmed by site facilities manager.
The in unit audio stations will be powered by POE off of network switches. Bay pines to provide electrical at head end for switches and power at security unit for master stations.
Services subtotal: $47,500.00
Materials qty unit price amount
IX Master Station 7" Black 2.0 $1,938.00 $3,876.00 7" Touchscreen IP Video Master Station, SIP Compatible, Privacy Handset, Includes Desk Stand, Black
Audio Station (in unit) 33.0 $1,665.82 $54,972.06 Station to have no buttons and no LEDS lights. 2-Gang Flush Mounted IP Door Station, No Buttons, No LEDs
Prudential Alarm, Inc.
Bay Pines Center 2425 N 30th St Escanaba, MI 49829 hollowaym@michigan.gov
CONTACT US
17515 W. Nine Mile Rd., Suite 1100 Southfield, MI 48075
(800) 252-0368 gwier@prudentialalarms.com
ESTIMATE #71438
ESTIMATE DATE Oct 21, 2024 EXPIRATION DATE Dec 20, 2024
TOTAL $116,753.30
Prudential Alarm, Inc. 3602206980 http://www.prudentialalarms.com 1 of 2 http://www.prudentialalarms.com
8 port POE switch 7.0 $357.58 $2,503.06
CAT5e Plenum Cable 33.0 $236.22 $7,795.26 Genesis 50885506 CAT5e Plenum Cable, 24/4 Solid BC, Unshielded, UTP, CMP, FT6, REELEX Pull Box, Blue double gang backbox 33.0 $3.24 $106.92
Materials subtotal: $69,253.30
Subtotal $116,753.30
Total $116,753.30
Prudential Alarm, Inc. 3602206980 http://www.prudentialalarms.com 2 of 2 http://www.prudentialalarms.com
A -4
C O
R R
M E
C H
A N
IC
A
L
G A
R A
G E
R E
C
IE
V E
/S T
O R
A G
E
M A
IN
T
O
F F
F
O O
D S
T O
R
S T
O R
A G
E
C O
R R
C O
R R
R E
F R
IG
F
R E
E Z
E
RC
O
R R
T L
T
D
IN
IN
G
K
IT
C H
E N
L A
U N
D R
Y
E N
T R
Y V
E S
T
L O
B B
Y
T L
T
C O
R R
C O
N T
R O
L C O
R R
ID
O
R IS
O
L A
T
IO
N
IS
O
L A
T
IO
N S
T O
R A
G E
S A
L L
Y P
O R
T
IN
T
A K
E H
O L
D
IN
T E
R
IE
WC
O
R R
ID
O
R
T L
T /S
H W
R
S T
O R
/L O
C K
E R
C O
N F
V
IS
IT
O R
F
IL
E S
C O
N F
E R
E N
C E
C O
R R
T L
T
D
IR
E C
T O
R
R .O
.S .S
B U
S M
G R
C L
E R
IC
A
L
C O
R R
A T
T
IN
T
E R
V
IE
W T
L T
F
S T
A F
F
M
S T
A F
F
S H
IF
T
A S
S E
L Y
C O
R R
C O
R R
F A
M
IL
Y T
R E
A T
O B
S E
R V
F
A M
IL
Y
T R
E A
T M
E N
T V
E S
T
J A
N
J A
N M
E C
H
M E
D
IC
A L
D E
N T
A L
M E
D T
L T
L A
B O
F F
IC
E
C O
R R
S T
O R
A G
E
M
L O
C K
E R
F
L O
C K
E R
T L
T
C O
R R
G Y
M N
A S
IU
M
C O
R R
E X
E R
C
IS
E
C O
R R
C O
R R
O F
F
IC
E
S T
O R
T
L T
S T
O R
A G
E
V E
S T
A V
S T
O R
A G
E
V O
C A
T
IO
N A
L
C L
A S
S R
O O
M
C L
A S
S R
O O
M
C O
R R
T L
T
T L
T
C L
A S
S R
O O
M
A R
T S
C
R A
F T
S
C O
R R
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
G R
O U
P M
E E
T
B P
O D
G R
O U
P M
E E
T
A P
O D
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
B D
R M
G R
O U
P M
E E
T
D P
O D
A L
L G
IR
L
'S R
E C
P O
D L
A U
N D
R Y
L A
U N
D R
Y
L A
U N
D R
Y
O F
F
IC
E
V E
S T
T L
T /S
H W
R
O F
F
IC
E
V E
S T
T L
T /S
H W
R
O F
F
IC
E
O F
F
IC
E S
T O
R A
G E
V
IS
IT
O
R
S N
A C
K L
A U
N D
R Y
V E
S T
O
F F
IC
E
T L
T /S
H W
R
O F
F
IC
E
V E
S T
A L
L G
IR
L
'S R
E C
P O
D
C O
R R
T L
T /S
H W
R
J A
N
T L
T /S
H W
R
V E
S T
C O
R R
A -4
G R
O U
P M
E E
T S
W
IN
G P
O D
M A
T C
H L
IN
E
M A
T C
H L
IN
E
1.
D O
N O
T S
C A
LE
D
R A
W
IN
G S
. I F
D
IM
E N
S
IO
N S
C A
N N
O T
B E
D E
T E
R M
IN
E
D O
R D
O C
U M
E N
T S
A R
E I
N
C
N F
LI
C
T , T
H E
C O
N T
R A
C T
O R
S H
A
LL
O B
T A
IN
C
LA
R
IF
IC
A T
IO
N
F R
O M
T H
E A
R C
H
IT
E C
T P
R
IO
R T
N T
IN
U
A T
IO
N
O F
W O
R K
2.
R E
F E
R T
O A
-0
F O
R M
A T
E R
IA
L
/ R E
F E
R E
N C
E S
Y M
B O
LS
A
N D
A B
B R
E V
IA
T
IO
N
S 3.
F
E R
T O
A -6
S
E R
IE
S
F O
R D
O O
R I
N F
O R
M A
T
IO
N A
N D
D E
T A
IL
S
, I N
C
LU
D
IN
G S
P E
C
IF
IC
N
O T
Q
U
IR
E D
F O
R E
A C
H D
O O
R L
IS
T
E D
4.
F
E R
T O
A -6
S
E R
IE
S
F O
R R
O O
M F
IN
IS
H S
C H
E D
U
LE
5.
LL
M A
S O
N R
Y D
IM
E
N S
IO
N
S A
R E
N O
M
IN
A L, U N
O
G E
N E
R A
L N
O T
E S
P
L A
N S
STATE OF MICHIGAN
DESIGN AND CONSTRUCTION DIVISION
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND
BUDGET STATE FACILITIES ADMINISTRATION
N
A R
C H
IT
E
C
G
IN
E E
P
LA
N
N E
R S
O H
M -A
D V
IS
O
R S
.C O
M
R
COPYRIGHT 2023 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM
ISSUED FOR: PROJECT NUMBERPMDISCIPLINE LEAD
ADAM P. LACH, RA, DIRECTOR
6/17/2025 10:33:29 AM Autodesk Docs://7136-23-0070 Bay Pines Door Replacement/7136230070_A_BPC_DR_2023_CEN.rvt
A -1
FIRST FLOOR PLAN
2425 N 30th St, Escanaba, MI 49829
MDHHS
BAY PINES CENTER | DOOR REPLACEMENT
BIDDING
7136-23-0070LMM
2023/12/01
491/23072.JBB
DTMB File No.
JB
1/
1' -0
F
IR
S T
F
LO
O R
P
LA
N
3BULLETIN #32024/12/04
4BULLETIN #42025/02/26
PT
T
PT PT
PT
PT
PT
P T
P T
P T
P T
P T
P T
PT
P T
PT
PT PT PT PT PT
PT
PT
PT PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PTPT
PT
PT
PTPT
PT
PT
P T
PT
P T
P T P
T
PT
PT
PT
PT
PT
P T
P T
P T
P T
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
P T
P T
P T
PT
PT
1.
D
N O
T S
C A
LE
D
R A
W
IN
G S
. I F
D
IM
E N
S
IO
N S
C A
N N
O T
B E
D E
T E
R M
IN
E
D O
R D
O C
U M
E N
T S
A R
E I
N F
LI
C
T , T
H E
C O
N T
R A
C T
O R
S H
A
LL
O B
T A
IN
C
LA
R
IF
IC
A T
IO
N
F R
O M
T H
E A
R C
H
IT
E C
T P
R
IO
R
N T
IN
U
A T
IO
N
O F
W O
R K
2.
F E
R T
O A
-0
F O
R M
A T
E R
IA
L
/ R E
F E
R E
N C
E S
Y M
B O
LS
A
N D
A B
B R
E V
IA
T
IO
N
3.
F
E R
T O
A -6
S
E R
IE
S
F O
R D
O O
R I
N F
O R
M A
T
IO
N A
N D
D E
T A
IL
S
, I N
C
LU
D
IN
G S
P E
C
IF
IC
N
O T
Q
U
IR
E D
F O
R E
A C
H D
O O
R L
IS
T
E D
4.
F
E R
T O
A -6
S
E R
IE
S
F O
R R
O O
M F
IN
IS
H S
C H
E D
U
LE
5.
LL
M A
S O
N R
Y D
IM
E
N S
IO
N
S A
R E
N O
M
IN
A L, U N
O
G E
N E
R A
L N
O T
E S
P
L A
N S
B D
R M
A
B D
R M
A
B D
R M
A
B D
R M
A
B D
R M
A
B D
R M
A
B D
R M
A
B D
R M
A
B D
R M
B
B D
R M
B
B D
R M
B
B D
R M
B
B D
R M
B
B D
R M
B
B D
R M
B
B D
R M
B
G R
O U
P M
E E
T
B P
O D
B
G R
O U
P M
E E
T
A P
O D
B
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
S
B D
R M
D
B D
R M
D
B D
R M
D
B D
R M
D
B D
R M
D
B D
R M
D
G R
O U
P M
E E
T
D P
O D
B
A L
L G
IR
L
'S R
E C
P O
D
B
L
A U
N D
R Y
B
L A
U N
D R
Y
B
G R
O U
P M
E E
T S
W
IN
G P
O D
B
L A
U N
D R
Y
B
O F
F
IC
E
B
V E
S T
B
T L
T /S
H W
R
B
O F
F
IC
E
B
V E
S T
B
T
L T
/S H
W R
B
O F
F
IC
E
B
O F
F
IC
E
B
S
T O
R A
G E
B
V
IS
IT
O
R
B
S N
A C
K
B
L A
U N
D R
Y
B
V E
S T
B
O F
F
IC
E
B
T L
T /S
H W
R
B
O F
F
IC
E
B
V E
S T
B
A L
L G
IR
L
'S R
E C
P O
D
B
C
O R
R
B
T L
T /S
H W
R
B
J A
N
B
T L
T /S
H W
R
B
V E
S T
B
C O
R R
B
E N
T R
Y V
E S
T
B
L O
B B
Y
B
C O
R R
B
C O
N T
R O
L
B
C O
R R
ID
O
R
B
IS
O
L A
T
IO
N
B
IS
O
L A
T
IO
N
B
S T
O R
A G
E
B
S A
L L
Y P
O R
T
B
IN
T
A K
E H
O L
D
B
IN
T
E R
IE
W
B
C O
R R
ID
O
R
B
T
L T
/S H
W R
B
S T
O R
/L O
C K
E R
B
C O
N F
V
IS
IT
O R
B
F
IL
E S
B
C O
N F
E R
E N
C E
B
C O
R R
B
T L
T
B
9a
D
IR
E C
T O
R
B
R .O
.S .S
B
B U
S M
G R
B
C L
E R
IC
A
L
B
C O
R R
B
A T
T
IN
T
E R
V
IE
W
A
T
L T
A
F
S T
A F
F
A
M E
D T
L T
A
L A
B
A
O F
F
IC
E
A
C O
R R
A
S T
O R
A G
E
A
M
L O
C K
E R
A
F
L O
C K
E R
A
T L
T
A
C O
R R
A
G Y
M N
A S
IU
M
A
C
O R
R
B
E X
E R
C
IS
E
B
C O
R R
B
C O
R R
B
O F
F
IC
E
B
S T
O R
B
T L
T
B
S T
O R
A G
E
B
V E
S T
B
A V
S T
O R
A G
E
B
V O
C A
T
IO
N A
L
A
C L
A S
S R
O O
M
A
C O
R R
A
A1
A2
A3
A4
A5
A
A
A
B
B
B3
B4
B5
B8
B7
B6
B55 6.
B55 6.
B
1.
B571.2
B
B
B
A
LI
G N
W
IT
H
M
U J
O
IN
T A
LI
G
N W
U
J O
IN
T
A
LI
G N
W
U J
O
IN
T
S4
S3
S2
S1
S5
S9
S10
S8
S7
S6
D1
D2
S11
D3
D4
D
D
B51 2.
B51
2.
B
B
D E
N T
A L
A
J A
N
A
M E
C H
A
A R
T S
C
R A
F T
S
A
C O
R R
A
M
S T
A F
F
A
S H
IF
T
A S
S E
L Y
A
J A
N
A
C O
R R
A
T L
T
A
C L
A S
S R
O O
M
A
T L
T
A
L A
U N
D R
Y
A
K
IT
C H
E N
A
D
IN
IN
G
A
C L
A S
S R
O O
M
A
C O
R R
A
V E
S T
A
F A
M
IL
Y T
R E
A T
M E
N T
A
O B
S E
R V
A
C O
R R
A
F A
M
IL
Y T
R E
A T
A
C O
R R
A
T L
T
B
B51 4b
B51 4a
B51 8a
B506a B506b
B505
B52
B53
B54 2a
B53 9b
B53 9a
B55 4b
B55 4a
B53 6b
B533
B206b
B206c
B
6a B
6d
B57
B55
B11 0a
B10 1a
A207
B122a
A13
A217d
A217c 01
A
7e
A
A212
A
B
7a
B573b B573a
B
5b
B551
M A
T C
H L
IN
E
M A
T C
H L
IN
E
B550
B
5a
03 03
S E
E C
O N
T
IN
U A
T
IO
N O
F F
IR
S
T F
L O
O R
P L
L A
R G
E D
N
O R
T H
A
T L
E F
T O
N T
H
IS
P A
G E
M A
T C
H L
IN
E
F
IN
IS
H
P L
A N
L E
G E
N D
F
IN
IS
H
E X
T E
N T
S
C L
A S
S R
O O
M
A
C O
R R
A
K
IT
C H
E N
A
F R
E E
Z E
R
A
R E
F R
IG
A
T L
T
A
F O
O D
S T
O R
A
R E
C
IE
V E
/S T
O R
A G
E
A
C O
R R
A
M A
IN
T
O
F F
A
C O
R R
A
M E
C H
A N
IC
A
L
A
S T
O R
A G
E
A
2a G
A R
A G
E
A
A30 3c
M A
T C
H L
IN
E
M A
T C
H L
IN
E
S E
E C
O N
T
IN
U A
T
IO
N O
F F
IR
S
T F
L O
O R
P L
L A
R G
E D
S
O U
T H
A
T R
IG
H
T O
N T
H
IS
P A
G E
STATE OF MICHIGAN
DESIGN AND CONSTRUCTION DIVISION
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND
BUDGET STATE FACILITIES ADMINISTRATION
N A
R C
H
IT
E C
G
IN
E
E
LA
N N
E R
S
O H
M -A
D V
IS
O
R S
.C O
M
R
COPYRIGHT 2023 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM
ISSUED FOR: PROJECT NUMBERPMDISCIPLINE LEAD
ADAM P. LACH, RA, DIRECTOR
6/17/2025 10:34:37 AM Autodesk Docs://7136-23-0070 Bay Pines Door Replacement/7136230070_A_BPC_DR_2023_CEN.rvt
A -4
ENLARGED PLANS
2425 N 30th St, Escanaba, MI 49829
MDHHS
BAY PINES CENTER | DOOR REPLACEMENT
BIDDING
7136-23-0070LMM
2023/12/01
491/23072.JBB
DTMB File No.
JB
1"
0'
-0
F
IR
S
T F
LO
O
R P
LA
N
E
N
LA
R G
E D
S
O U
T H
2BULLETIN #22024/10/31
3BULLETIN #32024/12/04
4BULLETIN #42025/02/26
1"
0'
-0
F
IR
S
T F
LO
O
R P
LA
N
E
N
LA
R G
E D
N
O R
T H
S H
E E
T K
E Y
N O
T E
S
P L A
N
IN
S
T A
LL
D
O O
R A
N D
H A
R D
W A
R E
IN
F
IL
L E
X
IS
T
IN
G D
O O
R O
P E
N
IN
G
IN
F R
A M
E W
IT
H
N E
W F
IX
E
D S
O
LI
D P
A N
E L
IN
S T
A
LL
D O
O R
F
R A
M E
A N
D H
A R
D W
A R
E
IN
S T
A
LL
F
IX
E D
P A
N E
L
IN
T O
E X
IS
T
IN
G
F R
A M
E
| 7136230070_A-411.pdf |
| Sheets |
| A-411 - ENLARGED PLANS |
| 7136230070_A-101.pdf |
| Sheets |
| A-101 - FIRST FLOOR PLAN |
File details come from the government source that posted it. Updated .