2. Existing Hydronic System.pdf

PDF 170 KB Posted

Attached to
490/25061. JBB; Bay Pines - Generator, HVAC, Fire Supp
Solicitation number
RFP 171 250000002458 3
Issued by
Delta County, Edmore Village, Michigan

About this file

This is a technical schematic document for an existing hydronic system prepared by the Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration, Design and Construction Division (File No. 431/15289.RAA, Index No. 65730). The document illustrates a comprehensive water treatment and hydronic distribution system serving multiple building zones including a gymnasium, garage, and receiving area. The system includes water treatment components (BF, BFP), pressure reducing valve stations, make-up water lines, and distribution to air handling units (AHU-1, AHU-2, AHU-3) via heat exchangers and balance valves. The schematic depicts interconnected piping with various diameters ranging from 1 to 4 inches, temperature sensors, pressure gauges, and a heat pump loop control system with dedicated supply and return lines. A chemical pot feeder for propylene glycol and water treatment is integrated into the system, with a high-limit shutdown control set at 120°F. The document notes that the existing air flow system schematics are provided for reference only and that existing controls are to remain in place.

The schematic indicates that a separate fire protection system should be isolated from the hydronic system, as indicated by the callout notation. The design incorporates dedicated outdoor air supply (DOAS-1) with face and bypass dampers for temperature control across multiple zones. A building management system (BMS) controls the domestic hot water preheating function on demand. The document serves as a technical reference for facility planning and does not contain information regarding pricing, contract terms, procurement timelines, or funding sources.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P L U R I B U E

S U N U M

C I R C U M S P I C E

S I QU EREI S P E N I N SU L AM AMOENA M

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

STATE OF MICHIGAN

ROBERT C. HALL, RA, NCARB, DIRECTOR

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

F

IL

E N

O . 4

/1

.R A

A

IN

D

E X

N O

. 6

WATER

TREATMENT

BF

P

BFP

T-3

T-1 T-2

M

P-1

P-2

P-3

P-4

ET-2

PRV STATION

3/4" MAKE-UP

WATER

4"

3" R-4B

2-1/2"

1-1/2"

2-1/2"

AHU-1

GARAGE AND RECEIVING

GYMNASIUM AHU-2,3

BALANCE VALVE (TYP.)

4" HWR

3"

3"

2-1/2"

HX-1

ET-1

FC-1

4" BYPASS

N.O.

4"

4"

4"

4"

FIRE

PROTECTION

SYSTEM RISER

1" COLD

WATER

R-4

4"

3"

P-5

P-6

P

2"

2" DRAIN

FIRE PROTECTION

BYPASS

CHEMICAL POT FEEDER

FOR PROPYLENE

GLYCOL AND CHEMICAL

TREATMENT OF WATER

N.O.

HIGH LIMIT TO SHUT-

DOWN AT 120°F

4"

PS-1

UH-2

UH-3

T

T

T

DUCTED OA FROM SOFFIT

DUCTED OA FROM SOFFIT

R A

R A

TS-2 PS-2

SA

SA

FACE AND

BYPASS

DAMPERS

FACE AND

BYPASS

DAMPERS

AHU-3

HC-2

AHU-2

HC-3

PRIMARY AIR MEDIUM PRESSURE

DUCT SYSTEM

P

PP

PRESSURE

GAUGE (TYP.) HEAT PUMP

LOOP

CONTROL

M

M M

TS-1

1.2" WC

MANUAL

BALANCING

DAMPER

8"

FILTER PLENUM WITH 8" ROUND

FA INLET AND 14x12 RA OPENING

HEAT

PUMP

FILTER PLENUM WITH 8" ROUND

FA INLET AND 14x12 RA OPENING

HEAT

PUMP

MANUAL

BALANCING

DAMPER

HOSE KIT WITH

AUTOFLOW CV

B-1 B-2

3"

4" 4"

P-7 P-8

HEAT PUMP SUPPLY

OUT TO BUILDING

HEAT PUMP RETURN

OUT TO BUILDING

3" 4"

T-4

T-5

T-6

T-7

UH-1

MIXED AIR

DAMPERS

MIXED AIR

DAMPERS

NEW DISCHARGE

AIR TEMPERATURE

SENSOR

4 4

SPACE

SENSORS

NOTE: EXISTING AIR FLOW

SYSTEM SCHEMATICS SHOWN

ARE FOR REFERENCE ONLY;

EXISTING CONTROLS TO REMAIN.

P-9

SEE ENLARGED DHWG-1

PLAN FOR CONTINUATION

CONTROLLED BY BMS

ENERGIZED ON CALL FOR

DOMESTIC HOT WATER.

PREHEATED

AIR TO COIL

T-8

DOAS-1

54" X 30"54" X 30"

40" X 20"

RHC-1

BarschJ Callout Separate Fire Protection System from Hydronic System