This is Addendum #1 to the Phase 3 Improvements project at F.J. McLain State Park, issued by Sanders & Czapski Associates, PLLC on behalf of the Michigan Department of Natural Resources. The addendum clarifies and revises information in the original Project Manual and Drawings, and all bidders were required to acknowledge receipt on their Bid Forms. A mandatory pre-bid meeting was held on April 26, 2022, at 3:00 PM ET via Zoom, with attendance from 18 representatives from various electrical, construction, and plumbing firms, as well as state agency personnel. The addendum addresses three primary areas: addition of Section 02 41 43 for Well Abandonment specifications; modifications to Sheet A1 regarding propane stove venting through the existing chimney with approval of Napoleon Knights Bridge GDS60-1NSB as an equal alternative to the Vermont Castings stove; and clarification of sidewalk and plaza dimensions on Sheet A2 per attached Sketch Ad1-1. The addendum also corrects an error on Sheet E2, noting that an outlet shown as existing on the east wall of the "Oaks" cabin does not exist and must be included as new work.
The Well Abandonment specifications require work to be performed by a Michigan-registered well drilling contractor in compliance with Part 127, Act 368 P.A. 1978, and local county health department requirements. Plugging materials include neat cement slurry, concrete slurry, granular bentonite/polymer slurry, or coarse-grade bentonite, with specific mixture proportions detailed in the specifications. The addendum includes well logs for two existing wells (Well ID 31000000372 and 31000000373) located adjacent to the well house that are scheduled for plugging and abandonment. Both wells are 6-inch diameter steel casing with depths of 55 feet and 54 feet respectively, equipped with Grundfos submersible pumps installed in 2014. The contractor must maintain complete written records of the plugging operation and submit a completed well plugging report to the Project Manager; payment shall be withheld until the report is approved.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SANDERS & CZAPSKI ASSOCIATES, PLLC
ARCHITECTURE / LANDSCAPE ARCHITECTURE / HISTORIC PRESERVATION
109 South Front Street / Suite 210 / Marquette, MI 49855
Phone: 906 – 273 - 1207
Phase 3 Improvements
F.J. McLain State Park
ADDENDUM #1
April 28, 2022
Project: Phase 3 Improvements – F.J. McLain State Park Department of Natural Resources
18530 M-203 Hancock, Michigan 49930
File No: 751/16043.JBB
Agency: Department of Natural Resources
Issued by: Sanders & Czapski Associates, PLLC 109 S. Front St., Suite 210 Marquette, Michigan 49855
Date: April 28, 2022
Notice to Bidders:
This Addendum serves to clarify, revise, and supersede information in the Project Manual, Drawings, and previously issued Addenda. Portions of the Addendum affecting the Contract Documents will be incorporated into the Contract by enumeration of the Addendum in the Owner/Contractor Agreement.
The Bidder shall acknowledge receipt of this Addendum in the appropriate space on the Bid Form(s)
The date, time and location for receipt of bids is unchanged by this Addendum.
Attachments to this Addendum:
This Addendum includes the following attached Documents.
o Mandatory Pre-Bid Meeting (4/26/2022) attendance log.
o Section 02 41 43 – Well Abandonment o Well logs for existing wells located adjacent to the well house that are scheduled for plugging and abandonment.
o Sketch Ad1-1, Layout Plan Birches Cabin Plaza.
The Specifications:
A. Section 02 41 43 – Well Abandonment
1. Add: Section 02 41 43 – Well Abandonment in its entirety, included as an attachment to this addendum.
The Drawings:
A. Sheet A1 – Floor Plan Birches Cabin
Add: Venting for the new propane stove is intended to be through the existing chimney including by using a manufacturer approved masonry chimney adapter direct vent kit with flexible vent pipe up through the existing chimney to a coaxial vent cap.
Add: Napoleon Knights Bridge GDS60-1NSB, Metallic Black and blower kit and safety barrier is hereby approved as an equal to the Vermont Castings stove originally specified.
B. Sheet A2 – Birches Rustic Cabin Site Plan.
Clarify: See attached sketch Ad1-1 for clarification of sidewalk and plaza dimensions.
C. Sheet E2 – Electrical Plan Mini-Cabins (Bid Alternate #2)
Add: The outlet shown as existing on the east wall of “Oaks” cabin does not exist. Include a new outlet at this location as part of the work circuited as shown.
END OF ADDENDUM #1
MEETING ATTENDANCE RECORD
MICHIGAN DEPARTMENT OF TECHNOLOGY MANAGEMENT AND BUDGET
FACILITIES AND BUSINESS ADMINISTRATION- DESIGN AND CONSTRUCTION DIVISION
PROJECT DESCRIPTION/LOCATION :
Phase 3 Improvements – F.J. McLain State Park, 18530 M-203, Hancock, MI 49930
DATE
April 26, 2022, 3:00 pm Virtual Mandatory Pre-Bid Meeting
INDEX NUMBER
51240
FILE NUMBER
751/16043.JBB
CONTRACT NUMBER
PSC Contract No. Y 16103
Construction Contract No. TBD
TIME
3:00 PM (ET)
MEETING PLACE
Via Zoom Meetings
NAME FIRM PHONE/CELL FAX EMAIL
Marty Hammerstrom
Keweenaw Electric
906-370-8020 martyh@kplelectric.com
Jared Rosenlund
Bay Electric Inc.
906-482-8784 jared@bayelectricinc.com
Karen Helppi
Moyle Construction
(906) 482-3000 kjhelppi@moyleusa.com
W. Paul Johnson
Walbec Group
920-843-3507 pjohnson@walbecgroup.com
Derek Wuebben
Northern Heating & Plumbing, Inc.
(906) 482-7580 derek.wuebben@gonhp.com
Randy Oja
MJO Contracting
906-482-8965 roja@mjocontracting.com
Courtney Gary
MKC Group, INC
989-439-1767 courtney@mkcmi.com
Jennifer Miller
Blue Restoration LLC (989) 615-4682 bluerestorationllc@yahoo.com mailto:martyh@kplelectric.com mailto:jared@bayelectricinc.com mailto:kjhelppi@moyleusa.com mailto:pjohnson@walbecgroup.com mailto:derek.wuebben@gonhp.com mailto:roja@mjocontracting.com mailto:courtney@mkcmi.com mailto:bluerestorationllc@yahoo.com
FILE NUMBER
751/16043.JBB
CONTRACT NUMBER
PSC Contract No. Y 16103
Construction Contract No. TBD
NAME FIRM PHONE/CELL FAX EMAIL
Todd Anderson
Erico Electric Inc
(906) 483-4906 todd@ericoelectric.com
Jed Wuebben
Wuebben Construction
906-370-7872 jed@wuebbenconstruction.com
Jeremy Coponen
John Coponen Construction 906-370-4942
Coponenconcrete@gmail.com
Jeff Barsch Michigan Dept. of Technology Management & Budget
906-251-0727 BarschJ@michigan.gov
Danielle Foertsch
Michigan Dept. of Technology
Management & Budget 517-331-5369 FoertschD@michigan.gov
Louise Hunt Michigan Dept. of Natural Resources
906-482-2627 HuntL4@michigan.gov
John Codere Michigan Dept. of Natural Resources
(906) 482-0278
CODEREJ@michigan.gov
Eric Cadeau Michigan Dept. of Natural Resources
906-241-8318 CadeauE@michigan.gov mailto:todd@ericoelectric.com mailto:jed@wuebbenconstruction.com mailto:Coponenconcrete@gmail.com mailto:BarschJ@michigan.gov mailto:FoertschD@michigan.gov mailto:HuntL4@michigan.gov mailto:CODEREJ@michigan.gov mailto:CadeauE@michigan.gov
FILE NUMBER
751/16043.JBB
CONTRACT NUMBER
PSC Contract No. Y 16103
Construction Contract No. TBD
FIRM PHONE/CELL FAX EMAIL
Doug Rich Sanders & Czapski Associates
(PSC)
906-201-4961 RichD@michigan.gov
Karisa Roell Coleman Engineering Co. (PSC) 906.774.3440 kroell@coleman-engineering.com
Bill Sanders Sanders & Czapski Associates
(PSC)
906-273-1207 Bill@Sanders-Czapski.com mailto:RichD@michigan.gov mailto:kroell@coleman-engineering.com mailto:Bill@Sanders-Czapski.com
Phase 3 Improvements - F.J. McLain State Park File No. 751/16043.JBB Index No. 51240
Addendum #1 – April 28, 2022
WELL ABANDONMENT 02 41 43 - 1
SECTION 02 41 43
WELL ABANDONMENT
PART 1 - GENERAL
1.1 DESCRIPTION
A. This section includes all labor and material necessary to remove existing well equipment and sealing of the well watertight in accordance with these specifications and the requirements of the local county health department and Part 127, Act 368 P.A. 1978 and administrative rules, Michigan Water
Well Construction and Pump Installation Code.
B. The Work includes excavating, removing of well system components such as pumps, drop pipe and centralizers, packer jets, check valves, screens and fittings; plugging the well casing, cutting and capping casing; backfilling; and site restoration.
1.2 SUBMITTALS
A. Product Data: Submit product data on material used to plug well.
B. Well Abandonment Form: Upon completion of The Work, submit a copy of the well abandonment form completed for the local county health department. If not required by the local county health department, submit the following information:
1. Plugging method used.
2. Quantities of plugging material used.
3. Description of unusual conditions encountered during plugging, such as excessive volume of grout materials, leakage of exterior casing, etc.
4. Statement that casing was pulled or left in place.
1.3 QUALITY ASSURANCE
A. Well plugging shall be performed by a well drilling contractor registered in the State of Michigan, who shall comply with all applicable rules, regulations and guidelines published by the State of
Michigan, Department of Environmental Quality and local county health departments for well abandonment.
PART 2 - PRODUCTS
2.1 MATERIALS
A. Plugging Materials: Plugging material shall conform to one of the following types:
1. Neat cement slurry – a mixture of one bag (94 pounds) of Type 1 Portland cement to not more than six gallons of clean water. Two to four pounds of CaCl per bag can be added as an accelerator.
2. Concrete slurry – a mixture of one bag (94 pounds) of Type1 Portland cement to an equal amount of dry sand to not more than six gallons of clean water.
Phase 3 Improvements - F.J. McLain State Park File No. 751/16043.JBB Index No. 51240
WELL ABANDONMENT 02 41 43 - 2
3. Granular bentonite/polymer slurry – a mixture of course-ground (8-20 mesh) granular sodium bentonite and slurry composed of a non-toxic, non-fermenting liquid polymer and clean water.
The grout shall be prepared with the following proportions: 1 quart EZ-Mud per 100 gallons of water, or 0.2 pounds of Quick Gel per pound of water, to which Benseal is added at 1.5 pounds per gallon of slurry; or 3.5 pounds of Volclay UHS and 2.1 pounds of Volclay per gallon of water.
4. Coarse grade, bentonite – crushed high swelling sodium bentonite: the minimum particle size shall be ¼ inch in diameter.
B. Other plugging material shall be as approved by the Michigan Department of Environmental Quality prior to use.
PART 3 - EXECUTION
3.1 GENERAL
A. Unless otherwise specified, abandonment of the existing well shall take place after construction of the replacement water supply system to minimize Owner disruption.
B. Prior to plugging the well, make appropriate measurements to verify the well depth.
C. Maintain a complete and accurately written record of the plugging operation. The information to be recorded shall include the type of plugging material used, volume of material used, and method of placing the plugging material into the well. Such written record shall be available for inspection on site at the request of the PSC. Submit the completed well plugging report to the PSC. Payment to the Contractor shall be withheld by the Owner until the plugging report has been submitted and approved by the PSC.
D. Obtain water necessary for preparing the slurries and convey it in a clean, sanitary container.
E. Remove all materials from the well which may hinder its proper abandonment. This shall include pumping equipment, drop pipe, and packer jets. Removal of bremer check valves is not required.
F. Remove casing and screen.
G. Follow guidelines of Act 399, P.A. 1976 for abandoning flowing wells, wells containing gasses and wells in rock formations.
3.2 PLUGGING PROCEDURES
A. Slurry Mixture and Pumping: To avoid segregation or dilution of the sealing materials, place neat cement slurry, concrete slurry, or granular bentonite/polymer slurry into the well by pumping down a
1 inch I.D. minimum tremie pipe which has been placed with the discharge end at the bottom of the well. Use steel tremie for abrasive slurries. Determine the amount of slurry required to plug the well and apply slurry in one continuous operation until well is filled. Slowly raise the tremie pipe while the slurry is applied, keeping the end of the tremie pipe submerged in the slurry are all times.
Equipment used for pumping cement or bentonite slurries shall be of the diaphragm, piston or helical type. The volume of the slurry mixing tank shall be greater than the volume of the slurry required to plug the well in enable single-batch mixing of the slurry.
Phase 3 Improvements - F.J. McLain State Park File No. 751/16043.JBB Index No. 51240
WELL ABANDONMENT 02 41 43 - 3
B. Cement Slurries: Prepare neat cement or concrete slurries by adding cement or sand-and-cement to the calculated required volume of clean water. Recirculate the mixture through the pumping equipment until it is adequately mixed and free of lumps, then immediately pump into the well before initial set of the cement occurs.
C. Bentonite/Polymer Slurry: Mix granular bentonite/polymer slurry by adding the liquid polymer to clean water and circulate the mixture through the pump and back into the mixing tank. After adding enough polymer for proper proportion, stop the circulation pump. Spread granular bentonite evenly over the surface of the mixing tank while a paddle-type mixer, shovel, or hoe is used to mix the bentonite. Continue mixing until the slurry is free of lumps. Immediately pump the slurry through the tremie pipe into the well before the bentonite granules are extended.
D. Coarse Grade of Pelletized Bentonite: Slowly pour coarse grand of pelletized bentonite into the top of the well to avoid bridging of material in the casing of borehole. Place pellets of coarse bentonite into the well either by the handful or by scoop with a volume no larger than one cup, or by pouring at an even rate not to exceed five (5) minutes per fifty (50) pounds of material. Fine bentonite particles which accumulate in the bottom of the shipping container shall not be used. Place a work pipe or weighted drop string in the well and measure the height of the accumulated plugging material after each fifty (50) pounds of bentonite is placed in the well. If the measurement indicates that bridging of the plugging material has occurred, run a work pipe, drillrods, or other weighted device into the casing to break the bridge, and continue plugging operation until the bentonite appears at the surface.
Finally, place water into the casing to promote the expansion of the bentonite above the static water level.
3.3 CASING REMOVAL
A. Remove casing by applying a lifting force to the casing with the drilling rig, jacks, jarring head, or trip casing spear or a combination of the above methods. In overburden, remove the plugging material by applying a similar lifting force to the casing. In overburden, place the plugging material into the well after the screen is removed and prior to the removal of the casing so that the plugging material is in contact with the formation as the casing is being pulled. After 48 hours, return to the plugged hole and refill depression caused by settling grout material.
3.4 RESTORATION AND CLEANUP
A. Site Restoration: Restore the site to a condition that reasonably approaches the original condition of the property prior to the start of The Work. After pits are backfilled, grade the disturbed area to pre-existing ground contours. Provide topsoil, seed and mulch as necessary, to restore damaged areas to their original condition. See Section 32 92 00, Turf and Grasses.
B. Site Cleanup: Upon completion of The Work, remove from the premises all materials, debris, tools and machinery, plugging material, grease, or other materials which have accumulated on structures around the premises.
END OF SECTION 02 41 43
Water Well And Pump Record Completion is required under authority of Part 127 Act 368 PA 1978.
Failure to comply is a misdemeanor.Import ID:
Tax No: Permit No: County: Houghton Township: Hancock
Well ID: 31000000372 Elevation: 604 ft.
Latitude: 47.2393
Longitude: -88.60129
Method of Collection: GPS Std Positioning Svc SA Off
Source ID/Well No:
WSSN:
2005931
Section:
Well Status:
Active
Town/Range:
56N 34W
Distance and Direction from Road Intersection:
WELL 2 - EAST
Well Owner: MCLAIN STATE PARK Well Address:
HANCOCK, MI 49913
Owner Address:
HANCOCK, MI 49913
(Continued on page 2) This well was drilled under my supervision and this report is true to the best of my knowledge and belief.
Signature of Registered Contractor Date
Drilling Method: Cable Tool Well Depth: 55.00 ft. Well Use: Type II public Well Type: Unknown Date Completed: 8/11/1965
Pump Installed: Yes Pump Installation Only: Yes Pump Installation Date: 4/24/2014 HP: 1.50 Manufacturer: Grundfos Pump Type: Submersible Model Number: GR025515-9 Pump Capacity: 25 GPM Drop Pipe Length: 36.00 ft.
Drilling Record ID:Drop Pipe Diameter: 2.00 in.
Pump Voltage: 230
Draw Down Seal Used: No Pressure Tank Installed: Yes Pressure Tank Type: Diaphragm/bladder Manufacturer: Wellflo Model Number: WX-350 3 tanks Pressure Relief Valve Installed: Yes
Tank Capacity: 119.0 Gallons
Casing Joint: Unknown
Diameter: 6.00 in. to 45.00 ft. depth
Borehole:
Casing Type: Steel - black Height:
Casing Fitting: None
SAND MED. [5] [12] [5] SAND MED. [5] [12] [10] SAND MEDIUM TO
COARSE. [10] [12] [20] SAND FINE TO MEDIUM. [5] [11] [25] SAND FINE. [5]
[11] [30] SAND SILTY. [5] [16] [35] SAND SILTY. [5] [16] [40] SAND SILTY. [5]
[16] [45] GRAVEL FINE TO COARSE. [5] [21] [50] SAND SILTY. [5] [16]
Geology Remarks: (Continued On Page 2)
Formation Description Thickness Depth to Bottom
Sand Medium 5.00 5.00 Sand Medium 5.00 10.00 Sand Medium To Coarse 10.00 20.00 Sand Fine To Medium 5.00 25.00 Sand Fine 5.00 30.00 Sand Silty 5.00 35.00 Sand Silty 5.00 40.00 Sand Silty 5.00 45.00 Gravel Fine To Coarse 5.00 50.00 Sand Silty 5.00 55.00
Static Water Level: 11.00 ft. Below Grade Well Yield Test:
Pumping level 33.00 ft. after 8.00 hrs. at 60 GPM
Yield Test Method: Unknown
Well Grouted: Yes Grouting Material Unknown
Bags Additives Depth
0.00 0.00 ft. to 0.10 ft.None
Grouting Method: Unknown
Wellhead Completion: Pitless adapter, 12 inches above grade
Screen Installed: Yes
Slot 20.00
Set Between
45.00 ft. and 55.00 ft.10.00 ft.
Length
Filter Packed: No Blank: 0.00 ft. AboveScreen Diameter: 6.00 in.
Screen Material Type: Unknown Screen Installation Type: Unknown
Fittings: Neoprene packer
Drilling Machine Operator Name: A.E. SLAUGHTER Employment: Unknown Pump Installer: CURT LARSON 07-2521Type
Other
Nearest Source of Possible Contamination:
Distance 75 ft.
Direction North
Abandoned Well Plugged: No
Reason Not Plugged: Unknown
EQP-2017 (4/2010) LHD 2/20/2001 8:39 PMPage 1 of 2
Other Remarks: Contamination Source 1:Type Unknown General Remarks:
Tax No: Permit No: County: Houghton Township: Hancock
Well ID: 31000000372 Elevation: 604 ft.
Latitude: 47.2393
Longitude: -88.60129
Method of Collection: GPS Std Positioning Svc SA Off
Source ID/Well No:
WSSN:
2005931
Section:
Well Status:
Active
Town/Range:
56N 34W
Distance and Direction from Road Intersection:
WELL 2 - EAST
Well Owner: MCLAIN STATE PARK Well Address:
HANCOCK, MI 49913
Owner Address:
HANCOCK, MI 49913
LHD 2/20/2001 8:39 PM
[55]
GEOLOGY REMARKS:
Water Well Contractor's Certification This well was drilled under my supervision and this report is true to the best of my knowledge and belief.
Signature of Registered Contractor Date
Contractor Type: Unknown
Business Address:
Reg No:
Business Name:
Formation Description Thickness Depth to Bottom
(Continued from Page 1)
Water Well And Pump Record Completion is required under authority of Part 127 Act 368 PA 1978.
Failure to comply is a misdemeanor.
Import ID:
EQP-2017 (4/2010) Page 2 of 2
Water Well And Pump Record Completion is required under authority of Part 127 Act 368 PA 1978.
Failure to comply is a misdemeanor.Import ID:
Tax No: Permit No: County: Houghton Township: Hancock
Well ID: 31000000373 Elevation: 604 ft.
Latitude: 47.2394
Longitude: -88.60178
Method of Collection: GPS Std Positioning Svc SA Off
Source ID/Well No:
WSSN:
2005931
Section:
Well Status:
Active
Town/Range:
56N 34W
Distance and Direction from Road Intersection:
WELL 3 - EAST
Well Owner: MCLAIN STATE PARK Well Address:
HANCOCK, MI 49930
Owner Address:
HANCOCK, MI 49930
Contractor Type: Unknown
Business Address:
Reg No: 31-1722 Business Name:
Water Well Contractor's Certification This well was drilled under my supervision and this report is true to the best of my knowledge and belief.
Signature of Registered Contractor Date
Drilling Method: Cable Tool Well Depth: 54.00 ft. Well Use: Type II public Well Type: New Date Completed: 10/4/1990
Pump Installed: Yes Pump Installation Only: Yes Pump Installation Date: 4/24/2014 HP: 3.00 Manufacturer: Grundfos Pump Type: Submersible Model Number: GRU40S30-9 Pump Capacity: 40 GPM Drop Pipe Length: 34.00 ft.
Drilling Record ID:Drop Pipe Diameter: 2.00 in.
Pump Voltage: 230
Draw Down Seal Used: No Pressure Tank Installed: Yes Pressure Tank Type: Diaphragm/bladder Manufacturer: Well-X-Trol Model Number: WX-305 3 tanks Pressure Relief Valve Installed: Yes
Tank Capacity: 119.0 Gallons
Casing Joint: Welded
Diameter: 6.00 in. to 42.50 ft. depth
Borehole:
Casing Type: Steel - black Height: 1.50 ft. above grade
Casing Fitting: Drive shoe
SAND. [5] [34] [5] SAND. [5] [10] [10] SAND AND PEBBLES. [5] [10] [15]
SAND AND GRAVEL. [2] [19] [17] SAND GRAVEL CLAY. [6] [19] [23] SAND
AND GRAVEL. [31] [19] [54] FINE SAND. [2] [11] [56]
Geology Remarks:
Formation Description Thickness Depth to Bottom
Sand 5.00 5.00 Sand 5.00 10.00 Sand & Gravel 5.00 15.00 Sand & Gravel 2.00 17.00 Sand Gravel Clay 6.00 23.00 Sand & Gravel 31.00 54.00 Sand Fine 2.00 56.00
Static Water Level: 11.00 ft. Below Grade Well Yield Test:
Pumping level 35.00 ft. after 4.00 hrs. at 33 GPM
Yield Test Method: Unknown
Well Grouted: Yes Grouting Material Bentonite slurry
Bags Additives Depth
0.00 0.00 ft. to 0.10 ft.None
Grouting Method: Unknown
Wellhead Completion: Pitless adapter, 12 inches above grade
Screen Installed: Yes
Slot 12.00
Set Between
42.50 ft. and 54.00 ft.13.00 ft.
Length
Filter Packed: No Blank: 0.00 ft. AboveScreen Diameter: 6.00 in.
Screen Material Type: Unknown Screen Installation Type: Unknown
Fittings: Neoprene packer
Drilling Machine Operator Name: GEORGE KERANEN Employment: Unknown Pump Installer: CURT LARSON 07-2521Type
Septic tank
Nearest Source of Possible Contamination:
Distance 110 ft.
Direction South
EQP-2017 (4/2010) LHD 2/20/2001 8:39 PMPage 1 of 1
Other Remarks:
General Remarks:
ar ch it ec tu re l an ds ca p e a rc hi te ct ur e h is to ri c p re se rv at io n
S ou th F ro nt
S tr ee t /
S ui te
M ar qu et te
M ic hi ga n
P ho ne
. 2
. 1
S A
N D
E R
S
C Z
A P
S K
I A
S S
O C
IA
T
E S dd en du m
S ke tc h
A d1
-1 pr il
, 2
F ile
N o.
.J B
B
D ep ar tm en t of
N at ur al
R es ou rc es
P ha se
Im pr ov em en ts
F
J
M cL ai n S ta te
P ar k
H an co ck
M ic hi ga n
FROM SHEET A2 OF THE DRAWINGS
File details come from the government source that posted it. Updated .