About this file
This document includes construction drawings for a new hunter check station building to be constructed at the Aransas National Wildlife Refuge in Texas. The drawings specify the materials and layout for the building, including metal stud walls, gypsum board and ceiling surfaces, plumbing fixtures, lighting fixtures, and roofing materials. Dimensions and specifications are provided for the office, toilet room, sinks, cooler, closets, columns, concrete work, and drainage system. Electrical notes refer to separate drawings. Ceiling and lighting schedules include additional details.
The related federal contract opportunity is seeking furniture for six new buildings being constructed at the Aransas National Wildlife Refuge. The solicitation is for the Department of the Interior Fish and Wildlife Service and includes furniture needs for the hunter check station building and other structures depicted in the construction drawings.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALL LEGEND
INDICATES METAL STUD WALL WITH GYPSUM BOARD
INDICATES EXTERIOR CONCRETE TILT WALL
INDICATES EXTERIOR CONCRETE TILT WALL WITH FURR WALL
INDICATES METAL STUD WALL WITH INSULATION AND
GYPSUM BOARD
NOTE: REFER TO FINISH SCHEDULE FOR WALL FINISHES
OFFICE
TOILET ROOM
80110' x 12'
SINKSINK
CLOSET
A3.50
A3.50
A3.50
A3.50
D800
D801
W1
/4
/8
2' - 10" 3' - 4"
1' - 8"
3' - 0" 2' - 4"
A5
A1
A6
A2
A3
A4
8" 5
"A7
A8 A8 A8
G1 G4 G7 32' - 9"
8' - 0" 8" 10' - 3" 8" 13' - 2"
GA
GB
8' - 8" 10' - 3"
8' - 0" 10' - 11" 13' - 10"
COLUMNS
OVERALL
WALLS
WALLS
8"
G3
I3
I3
I3 2 I3
A9
CONTINUOUS DOWNPOUT
34' - 3"
DSDS
DS
G1 G4 G7
GA
GB
9"
CONTINUOUS DOWNSPOUT
34' - 3"
DS
32' - 9"
G3
/2
9"
A.F.F.
GWB on Mtl. Stud
9' - 0"
GYP-#
A.F.F.
GWB on Mtl. Stud
9' - 0"
GYP-#
OPEN
OPEN
B B B
BB
B
C C
C C
C C
G1 G4 G7
GA
GB
G3
RCP LEGEND
INDICATES 6" LED RECESSED CAN FIXTURE
INDICATES EXTERIOR WALL PACK DECORATIVE FIXTURE
INDICATES EMERGENCY EXIT SIGN
C
WALL
PACK
EXIT
INDICATES GYPSUM BOARD CEILING
INDICATES 4'-0" LED HANGING STRIP FIXTURE
A
T S
TE
OF TE
X
A S
C T
E T
R E G
IS
TE
RED
ARCH
I
26467
E
N O
S
DUHJ.
C I
R
E
TH
S T.
B
LD
G
B
S
TE
A
U S
TI
N
TE
X A
S
D A
T E
C
M E
T H
O D
A R
C H
IT
E
C T
U R
E
P L L C
C O
P Y
R
IG
H T
T H
E S
E D
R A
W
IN
G S
A R
E T
H E
P R
O P
E R
T Y
O F
M E
T H
O D
A R
C H
IT
E
C T
U R
E
L L C
A N
D M
A Y
N O
T B
E R
E P
R O
D U
C E
D
M O
D
IF
IE
D
N
O R
U S
E D
I N
A N
Y W
A Y
W
IT
H O
U T
T H
E
E X
P R
E S
S E
D W
R
IT
T E
N P
E R
M
IS
S
IO
N O
F M
E T
H O
D
A R
C H
IT
E
C T
U R
E
L L C
A R
A N
S A
S N
A T
IO
N
A L
W
IL
D L
IF
E
R E
F U
G E
A U
S T
W E
L L
T
X
A .0
.0
.2
M A
H U
N
TE
R C
H E C
K S
TA
TI
O N
F
LO
O R
R
O O
F A
N D
R C
P P
LA
N
ENVELOPE INFILTRATION REQUIREMENTS
BUILDING SHALL MEET ALL APPROPRIATE ENVELOPE INFILTRATION REQUIREMENTS
OF THE IEC, INCLUDING BUT NOT LIMITED TO:
ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING ENVELOPE SHALL BE
CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED.
MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION
RATES CERTIFIED BY THE MANUFACTURER.
FLOOR PLAN KEYNOTES
A1 BUILD RESTROOM AS INDICATED - MUST CONFORM TO ALL REQUIREMENTS
OF THE IBC AND TAS STANDARDS
A2 PROVIDE 8'-6" LONG LOWER CABINETS AND 8'-6" UPPER CABINETS.
CABINETS TO COMPLY WITH ALL TAS REQUIREMENTS.
A3 PROVIDE 6'-7" LONG CLOSET SPACE WITH HANGING RACK, SHELVING, AND
ACCORDION DOOR. TO COMPLY WITH ALL TAS REQUIREMENTS.
A5 PROVIDE STAINLESS STEEL SINKS AND FAUCET.
A6 PROVIDE 10' X 12' COOLER. RE STRUCTURAL FOUNDATION DRAWINGS.
A7 PROVIDE CONCRETE PAVING SEPARATE FROM BUILDING SLAB. RE:CIVIL
DRAWINGS
A8 PROVIDE METAL COLUMN. RE: STRUCTURAL DRAWINGS
A9 PROVIDE OVERHEAD TRACK FOR BUTCHER HANGERS
ELECTRICAL NOTES
REFERENCE ELECTRICAL DRAWINGS FOR POWER AND DATA LOCATIONS
1/4" = 1'-0"
HUNTER CHECK STATION
N
TRUE PLAN
N
ROOF DRAINAGE CALCULATIONS
ROOF AREA IN2 OF DRAINAGE REQUIRED [ROOF AREA/150]
901 SF 6 in²
GENERAL ROOF AND DRAINAGE NOTES
ROOF TYPE:
STANDING SEAM METAL ROOF - RE: PEMB AND ROOF MANUFACTURERS SPECIFICATIONS
DRAINAGE SYSTEM:
PROVIDE CONTINUOUS PREFINISHED METAL BOX GUTTER WITH DOWNSPOUTS, TIE INTO
STORM SYSTEM
DOWNSPOUT SCHEDULE AND CALCULATIONS
TAG COUNT HEIGHT DEPTH WIDTH
IN2 OF DRAINAGE
PROVIDED
COMMEN
TS
DS 4 9' - 9 3/16" 0' - 4" 0' - 5" 80.00 in²
TOTALS: 4 4 80.00 in²1/4" = 1'-0"
HUNTER CHECK STATION ROOF PLAN
CEILING SCHEDULE
MARK Description HEIGHT COMMENTS Area
GYP-# GYP. BOARD 9' - 0" 189 SF
LIGHTING FIXTURE SCHEDULE
FIXTURE
FIXTURE
WIDTH
FIXTURE
LENGTH
FIXTURE
AFF COUNT DESCRIPTION
B 4' - 0" 9' - 0" 6
C 9' - 0" 6
W 4 WALL PACK - LED
1/4" = 1'-0"
HUNTER CHECK STATION RCP
N
TRUE PLAN
N
N
TRUE PLAN
N
GENERAL NOTES
1/4" = 1'-0"
RCP LEGEND
.1
.2
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
.0
.2
A S
I-https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016