A2_06__HUNTER_CHECK_STATION_FLOOR__ROOF_AND_RCP_PLAN_Rev_7_markup.pdf

PDF 495 KB Posted

Attached to
TX- ARANSAS NWR-FURNITURE FOR ALL NEW BU
Solicitation number
140F0421Q0092
Issued by

About this file

This document includes construction drawings for a new hunter check station building to be constructed at the Aransas National Wildlife Refuge in Texas. The drawings specify the materials and layout for the building, including metal stud walls, gypsum board and ceiling surfaces, plumbing fixtures, lighting fixtures, and roofing materials. Dimensions and specifications are provided for the office, toilet room, sinks, cooler, closets, columns, concrete work, and drainage system. Electrical notes refer to separate drawings. Ceiling and lighting schedules include additional details.

The related federal contract opportunity is seeking furniture for six new buildings being constructed at the Aransas National Wildlife Refuge. The solicitation is for the Department of the Interior Fish and Wildlife Service and includes furniture needs for the hunter check station building and other structures depicted in the construction drawings.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALL LEGEND

INDICATES METAL STUD WALL WITH GYPSUM BOARD

INDICATES EXTERIOR CONCRETE TILT WALL

INDICATES EXTERIOR CONCRETE TILT WALL WITH FURR WALL

INDICATES METAL STUD WALL WITH INSULATION AND

GYPSUM BOARD

NOTE: REFER TO FINISH SCHEDULE FOR WALL FINISHES

OFFICE

TOILET ROOM

80110' x 12'

SINKSINK

CLOSET

A3.50

A3.50

A3.50

A3.50

D800

D801

W1

/4

/8

2' - 10" 3' - 4"

1' - 8"

3' - 0" 2' - 4"

A5

A1

A6

A2

A3

A4

8" 5

"A7

A8 A8 A8

G1 G4 G7 32' - 9"

8' - 0" 8" 10' - 3" 8" 13' - 2"

GA

GB

8' - 8" 10' - 3"

8' - 0" 10' - 11" 13' - 10"

COLUMNS

OVERALL

WALLS

WALLS

8"

G3

I3

I3

I3 2 I3

A9

CONTINUOUS DOWNPOUT

34' - 3"

DSDS

DS

G1 G4 G7

GA

GB

9"

CONTINUOUS DOWNSPOUT

34' - 3"

DS

32' - 9"

G3

/2

9"

A.F.F.

GWB on Mtl. Stud

9' - 0"

GYP-#

A.F.F.

GWB on Mtl. Stud

9' - 0"

GYP-#

OPEN

OPEN

B B B

BB

B

C C

C C

C C

G1 G4 G7

GA

GB

G3

RCP LEGEND

INDICATES 6" LED RECESSED CAN FIXTURE

INDICATES EXTERIOR WALL PACK DECORATIVE FIXTURE

INDICATES EMERGENCY EXIT SIGN

C

WALL

PACK

EXIT

INDICATES GYPSUM BOARD CEILING

INDICATES 4'-0" LED HANGING STRIP FIXTURE

A

T S

TE

OF TE

X

A S

C T

E T

R E G

IS

TE

RED

ARCH

I

26467

E

N O

S

DUHJ.

C I

R

E

TH

S T.

B

LD

G

B

S

TE

A

U S

TI

N

TE

X A

S

D A

T E

C

M E

T H

O D

A R

C H

IT

E

C T

U R

E

P L L C

C O

P Y

R

IG

H T

T H

E S

E D

R A

W

IN

G S

A R

E T

H E

P R

O P

E R

T Y

O F

M E

T H

O D

A R

C H

IT

E

C T

U R

E

L L C

A N

D M

A Y

N O

T B

E R

E P

R O

D U

C E

D

M O

D

IF

IE

D

N

O R

U S

E D

I N

A N

Y W

A Y

W

IT

H O

U T

T H

E

E X

P R

E S

S E

D W

R

IT

T E

N P

E R

M

IS

S

IO

N O

F M

E T

H O

D

A R

C H

IT

E

C T

U R

E

L L C

A R

A N

S A

S N

A T

IO

N

A L

W

IL

D L

IF

E

R E

F U

G E

A U

S T

W E

L L

T

X

A .0

.0

.2

M A

H U

N

TE

R C

H E C

K S

TA

TI

O N

F

LO

O R

R

O O

F A

N D

R C

P P

LA

N

ENVELOPE INFILTRATION REQUIREMENTS

BUILDING SHALL MEET ALL APPROPRIATE ENVELOPE INFILTRATION REQUIREMENTS

OF THE IEC, INCLUDING BUT NOT LIMITED TO:

ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING ENVELOPE SHALL BE

CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED.

MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION

RATES CERTIFIED BY THE MANUFACTURER.

FLOOR PLAN KEYNOTES

A1 BUILD RESTROOM AS INDICATED - MUST CONFORM TO ALL REQUIREMENTS

OF THE IBC AND TAS STANDARDS

A2 PROVIDE 8'-6" LONG LOWER CABINETS AND 8'-6" UPPER CABINETS.

CABINETS TO COMPLY WITH ALL TAS REQUIREMENTS.

A3 PROVIDE 6'-7" LONG CLOSET SPACE WITH HANGING RACK, SHELVING, AND

ACCORDION DOOR. TO COMPLY WITH ALL TAS REQUIREMENTS.

A5 PROVIDE STAINLESS STEEL SINKS AND FAUCET.

A6 PROVIDE 10' X 12' COOLER. RE STRUCTURAL FOUNDATION DRAWINGS.

A7 PROVIDE CONCRETE PAVING SEPARATE FROM BUILDING SLAB. RE:CIVIL

DRAWINGS

A8 PROVIDE METAL COLUMN. RE: STRUCTURAL DRAWINGS

A9 PROVIDE OVERHEAD TRACK FOR BUTCHER HANGERS

ELECTRICAL NOTES

REFERENCE ELECTRICAL DRAWINGS FOR POWER AND DATA LOCATIONS

1/4" = 1'-0"

HUNTER CHECK STATION

N

TRUE PLAN

N

ROOF DRAINAGE CALCULATIONS

ROOF AREA IN2 OF DRAINAGE REQUIRED [ROOF AREA/150]

901 SF 6 in²

GENERAL ROOF AND DRAINAGE NOTES

ROOF TYPE:

STANDING SEAM METAL ROOF - RE: PEMB AND ROOF MANUFACTURERS SPECIFICATIONS

DRAINAGE SYSTEM:

PROVIDE CONTINUOUS PREFINISHED METAL BOX GUTTER WITH DOWNSPOUTS, TIE INTO

STORM SYSTEM

DOWNSPOUT SCHEDULE AND CALCULATIONS

TAG COUNT HEIGHT DEPTH WIDTH

IN2 OF DRAINAGE

PROVIDED

COMMEN

TS

DS 4 9' - 9 3/16" 0' - 4" 0' - 5" 80.00 in²

TOTALS: 4 4 80.00 in²1/4" = 1'-0"

HUNTER CHECK STATION ROOF PLAN

CEILING SCHEDULE

MARK Description HEIGHT COMMENTS Area

GYP-# GYP. BOARD 9' - 0" 189 SF

LIGHTING FIXTURE SCHEDULE

FIXTURE

FIXTURE

WIDTH

FIXTURE

LENGTH

FIXTURE

AFF COUNT DESCRIPTION

B 4' - 0" 9' - 0" 6

C 9' - 0" 6

W 4 WALL PACK - LED

1/4" = 1'-0"

HUNTER CHECK STATION RCP

N

TRUE PLAN

N

N

TRUE PLAN

N

GENERAL NOTES

1/4" = 1'-0"

RCP LEGEND

.1

.2

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

.0

.2

A S

I-https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518016

File details come from the government source that posted it. Updated .