This document includes floor plans for proposed maintenance and boat barn buildings for the Aransas National Wildlife Refuge in Texas. The plans specify layouts for areas including equipment storage, wood and parts rooms, offices, restrooms, and boat storage. Construction requirements are also outlined, such as envelope infiltration standards and fire code compliance measures. The related federal contract opportunity is to provide furniture for six new buildings on the refuge, including lower and upper cabinets, lockers, washers and dryers, and concrete bollards.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALL LEGEND
INDICATES METAL STUD WALL WITH GYPSUM BOARD
INDICATES EXTERIOR CONCRETE TILT WALL
INDICATES EXTERIOR CONCRETE TILT WALL WITH FURR WALL
INDICATES METAL STUD WALL WITH INSULATION AND
GYPSUM BOARD
NOTE: REFER TO FINISH SCHEDULE FOR WALL FINISHES
MAINTENANCE SHOP
EQUIPMENT STORAGE
BREAK AREA
WOOD SHOP
59' - 10 7/8"
MECH / ELEC
JAN.
OFFICE
MEN'S RR
WOMEN'S RR
STORAGE
TOOL ROOM
PARTS ROOM
DATA
LOCKERS
LAUNDRY
WASH BAY
DE
DD
DC
DB
DA
A3.30
A3.30
A3.30
A3.30
/2
/2
LOCKER ROOM
D514
D515A D504
D500D
D508
D515C
D515B
D515D
D515E
D503
D500G
D500H
D500B
D500E
D500F
D500A
D511
D513
D505
D506
D507
D512
D500C
D502
D501
D510
14' - 2 3/4" 4' - 9 3/4"
5' - 4 7/8"
5' - 4 3/8" 6' - 10" 21' - 11 1/4"
/8
/8
/4
/8
19' - 0 1/2" 5' - 4 7/8" 12' - 2 3/8" 8' - 7 1/8" 5' - 5" 7' - 11 1/8"
/8
/8
/4
/2
/8
/8
/8
/8
A6
1' - 7"
A2
A1
A1
A6.30
A3
A6
A6.30
A6
A6
A3
A3
A6
A6
A6
A3
STORAGE
/8
A3
D509
ADA
1' - 4 3/8"
A4
A6.30
A7.06
A1
A1
/8
A7
A7
A7
A7
A7
D1 D2 D6D5D3 D4
8" 18' - 11 1/2" 17' - 0" 22' - 8 1/2"
8"
60' - 0"
A3
A7
A7
A7
A7
A7
A7
A7
A7
A7
A7
A7
A7
D515F
A8
A8
A8
A8
A8
A8 A8
A8
BOAT BARN
CANOPY OVERHEAD
CANOPY OVERHEAD
LEAN-TO PARKING
LEAN-TO PARKING
/8
/8
EQUIPMENT STORAGE
EF
EA
A3.31
A3.31
A3.31
A3.31
EC
ED
/8
E3
EE
EB
29' - 6"
54' - 11" 3' - 5" 1' - 8"
D600DD600C
D600E
D601 9
/8
60' - 0"
' - 0
' - 5
/2
' - 9
' - 2
30' - 0
12' - 0"
/8 "38' - 9
1/4"
' - 0
A7
A7 A7
A7
A7A7
E2E1 E4 E5
6" 29' - 6"
6"
A7 A7
A7
A7 A7A7A7
A
T S
TE
OF TE
X
A S
C T
E T
R E G
IS
TE
RED
ARCH
I
26467
E
N O
S
DUHJ.
C I
R
E
TH
S T.
B
LD
G
B
S
TE
A
U S
TI
N
TE
X A
S
D A
T E
C
M E
T H
O D
A R
C H
IT
E
C T
U R
E
P L L C
C O
P Y
R
IG
H T
T H
E S
E D
R A
W
IN
G S
A R
E T
H E
P R
O P
E R
T Y
O F
M E
T H
O D
A R
C H
IT
E
C T
U R
E
L L C
A N
D M
A Y
N O
T B
E R
E P
R O
D U
C E
D
M O
D
IF
IE
D
N
O R
U S
E D
I N
A N
Y W
A Y
W
IT
H O
U T
T H
E
E X
P R
E S
S E
D W
R
IT
T E
N P
E R
M
IS
S
IO
N O
F M
E T
H O
D
A R
C H
IT
E
C T
U R
E
L L C
A R
A N
S A
S W
IL
D
L
IF
E R
E F
U G
E A
U S
T W
E L
L
T X
A .0
/0
/2
M A
M A
IN
TE
N A
N C
E B
U
IL
D
IN
G A
N D
B O
A T
B A
R N
F
LO
O R
P
LA
N S
N
ENVELOPE INFILTRATION REQUIREMENTS
BUILDING SHALL MEET ALL APPROPRIATE ENVELOPE INFILTRATION REQUIREMENTS
OF THE IEC, INCLUDING BUT NOT LIMITED TO:
ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING ENVELOPE SHALL BE
CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED.
MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION
RATES CERTIFIED BY THE MANUFACTURER.
FIRE CODE COMPLIANCE
OWNER SHALL PROVIDE PORTABLE FIRE EXTINGUISHER PER NFPA 10
AUTOMATIC FIRE SPINKLER PLANS AND SPECIFICATIONS SHALL BE PRESENTED
FOR REVIEW AND APPROVAL PRIOR TO SYSTEM INSTALLATION / ALTERATION
FIRE ALARM PLANS AND SPECIFICATIONS SHALL BE PRESNTED FOR REVIEW AND
APPROVAL PRIOR TO SYSTEM INSTALLATION / ALTERATION
FIRE ALARM SIGNAL DEVICE PLAN AND SPECIFICATIONS SHALL BE PRESENTED
FOR REVIEW AND APPROVAL PRIOR TO SYSTEM INSTALL / ALTERATION AND WILL
BE CONNECTED TO BUILDING FIRE ALARM SYSTEM
FIRE ALARM AND DETECTION REQUIREMENTS - SPRINKLERED
MANUAL FIRE ALARM - SECTION 907.2
B: NOT REQUIRED FOR SPRINKLERED BUILDINGS WITH OCCUPANT NOTIFICATION
S: NOT REQUIRED
ALARM MONITORING
PROVIDE SYSTEM FOR MONITORING SPRINKLERS - SYSTEM TO COMPLY WITH NFPA 72
AUTOMATIC FIRE DETECTION SYSTEM - SECTION 907.2
A: NOT REQUIRED
B: NOT REQUIRED
OCCUPANT NOTIFICATION
PROVIDE SYSTEM FOR NOTIFYING OCCUPANTS - SYSTEM TO COMPLY WITH NFPA 72
FIRE-RESISTANCE RATING REQUIREMENTS
BUILDING ELEMENTS, HOURS (IBC TABLE 601)
TYPE IIB CONSTRUCTION
REQUIRED
RATING
(HOURS)
PRIMARY STRUCTURAL FRAME
BEARING WALLS - EXTERIOR
BEARING WALLS - INTERIOR
NONBEARING WALLS AND PARTITIONS - INTERIOR
FLOOR CONSTRUCTION / SECONDARY MEMBERS
ROOF CONSTRUCTION / SECONDARY MEMBERS
REQUIRED
RATING
(HOURS)
FLOOR PLAN KEYNOTES
A1 BUILD RESTROOM AS INDICATED - MUST CONFORM TO ALL REQUIREMENTS
OF THE IBC AND TAS STANDARDS
A2 PROVIDE 14'-0" LONG LOWER CABINETS WTIH DOUBLE SINK, AND 14'-0"
UPPER CABINETS. CABINETS TO COMPLY WITH ALL TAS REQUIREMENTS.
A3 PROVIDE FLOOR SINK AS SHOWN. WALLS AROUND SINK TO BE FRP
MATERIAL 4'-0" HIGH.
A4 PROVIDE LOCKERS AT NOTED LOCATION. TO COMPLY WITH ALL TAS
REQUIREMENTS.
A6 PROVIDE WASHER AND DRYER AT NOTED LOCATION.
A7 PROVIDE CONCRETE FILLED BOLLARD AT NOTED LOCATION.
A8 TRENCH DRAINS AT NOTED LOCATION. RE: MEP AND STRUCTURAL
DRAWINGS
FIRE EXTINGUISHER SCHEDULE
TAG COUNT MOUNT TYPE DESCRIPTION
1/8" = 1'-0"
MAINTENANCE BUILDING FLOOR PLAN
ELECTRICAL NOTES
REFERENCE ELECTRICAL DRAWINGS FOR POWER AND DATA LOCATIONS
1/8" = 1'-0"
BOAT HOUSE FLOOR PLAN
N
TRUE NORTH
N N
TRUE NORTH
GENERAL NOTES
.1
.2
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
.0
.2
A S
I
RFI 66
RFI 65
https://app.procore.com//1034659/project/rfi/show/9596895 https://app.procore.com//1034659/project/rfi/show/9596734 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798750 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798750 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798750 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798750 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798749 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798749 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798749 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798749 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518044 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518044 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/129518044
File details come from the government source that posted it. Updated .