A2_03__BUNK_HOUSE_OVERALL_FLOOR_PLAN_Rev_9_markup.pdf

PDF 608 KB Posted

Attached to
TX- ARANSAS NWR-FURNITURE FOR ALL NEW BU
Solicitation number
140F0421Q0092
Issued by

About this file

This document provides a floor plan for a proposed bunk house at the Aransas National Wildlife Refuge in Texas. The floor plan depicts 16 bunk rooms of varying sizes, two larger living areas, a kitchen, laundry room, exercise room, and multiple bathrooms. Plumbing and electrical connections are indicated for tenant-provided appliances. Construction will meet fire code requirements including sprinklers, smoke alarms, and a fire alarm system. The building envelope must meet infiltration standards and fire resistance ratings are specified for structural elements. Related to this project is a federal contract opportunity to provide furniture for six new buildings at the Aransas National Wildlife Refuge in Texas. Furnishings are needed to outfit the proposed bunk house and other structures. The solicitation number is provided along with the contracting agency, the US Fish and Wildlife Service. Responses are due by a specified date.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FD

FD

FD

WALL LEGEND

INDICATES 4" INTERIOR METAL STUD WALL

INDICATES EXTERIOR PRE-CAST CONCRETE WALL

NOTE: REFER TO FINISH SCHEDULE FOR WALL FINISHES

INDICATES 4" INTERIOR METAL STUD WALL WITH INSULATION

BR 01

BR 04 - ADA

BR 02 - ADA

BATHROOM 02

BATHROOM 01

BR 03

EXERCISE ROOM

BR 09

BR 07 - ADA

LAUNDRY

MECH.

BR 06

307BR 08

KITCHEN

300B

DINING / LIVING AREA

300A

/8

/4

/8

A3.20

A3.20

BATHROOM 03

/8

/4

/8

BATHROOM 04

A4.03

A4.03

A4.03

A4.03

1' - 10"3' - 4" 2' - 5 1/16"

1' - 0"

2' - 6"2' - 0"

5' - 0"

2' - 0"

2' - 10" 3' - 4"

1' - 0 1/2" 3' - 4"

1' - 11 3/16"

3' - 0"

1' - 0"

1' - 0" 5' - 0 1/4"

41' - 8"

5' - 0 1/4"

1' - 0"

1' - 0"

3' - 0"

1' - 0"

3' - 4" 10' - 0" 3' - 4"

11 15/16"

1' - 0"

2' - 0"

1' - 0"

8' - 11 13/16" 11" 12' - 8 1/2"

" 3

/1

/1

D311A

D312

D310A

D314A

D307A

D306A

D303A

D302A

D310B

D315A

D313A

D300

D303B

D304

D306B

D316

D302B

D305

D307B

D311B

D301

A3.20

A3.20

13' - 6 5/16"

10' - 9 13/16"

14' - 10 7/8"

11"

A6.20

A6.21

A6.20

A6.20

/1

/1

12' - 1 1/2" 8' - 9 7/8" 11' - 10 5/8" 6' - 5" 11"

W21 W23 W21

A4 2 3

A3 5 3

A6 2 3

A3 2 3

A6 2 3

A4 2 3

A4

A4

A4 2 3

A3 2 3

A6 2 3

A6 2 3

A4 2 3

A3 2 3

A4

A4 2 3

A4 2 3

A4 2 3

A6 2 3

A4 2 3

A4 2 3

A2

A2 2 3

A2 2 3

A4 2 3

A4 2 3

A4 2 3

A4 2 3

A4 2 3

A4 2 3

A4 2 3

W21

W21

W22

W23

W21

W21

W23

W22

W22

W21

W25

W21W21W23W21

W21

W23

W23

W21

A6.20

W21

W23

W23

W21

W26

W24

D306CD303C

D307CD302C

D308

D314C

D314B

D315B

D313B

D310C

7' - 3 5/8"

31' - 11 3/8"

13' - 6 3/8"

10' - 9 3/4"

14' - 10 7/8"

C1 C2 C3

C5

C4

C6

C7

41' - 8"

5' - 0 1/4"

1' - 0" 1' - 0"

3' - 0"

1' - 0"

3' - 4" 9' - 11 3/4" 3' - 4"

1' - 0" 1' - 0"

2' - 0"

1' - 0"

9' - 0" 11"

CC

CD

CA

2' - 5" 39' - 3"

39' - 3"

2' - 5"

OPENINGS

COLUMNS

OVERALL

A6 2 3

A6 2 3

OPENINGS

COLUMNS

OVERALL

2' - 5" 39' - 3"

3' - 7 1/4" 3' - 4"

8"1' - 0"

2' - 6"

2' - 0"

15' - 4"

3' - 4"

9 1/4" 3' - 0"

1' - 0"1' - 0 1/2"

5' - 0"

41' - 8"

A1

A1

A1

A1

A3

A2

O P

E N

IN

G

S

O V

E R

A

LL

O P

EN

IN

G

S

O V

ER

A

LL

C8

/4

39' - 3"

2' - 5"

41' - 8"

105.3°

150.0°

15.0°

15.0°

I4 2 3

I4 2 3

I4 2 3

I4

I4

I4 2 3

I4 2 3

A6 2 3

A6 2 3

I4 2 3

I4 2 3

I4 2 3

A9

/4

10' - 10 1/2" 8' - 9 7/8" 5' - 1 5/8" 6' - 9" 6' - 5"

104.7°

/8

/1

/4

/4

D/W

D309

A4 5 3

A4

A4 2 3

A5

3' - 0"

I4 2 3

2' - 7"

I4 2 3

A2 2 3

A2 2 3

A2 2 3

A2 2 3

D313C

D315C

A5.03

A5.03SIM.

A

T S

TE

OF TE

X

A S

C T

E T

R E G

IS

TE

RED

ARCH

I

26467

E

N O

S

DUHJ.

C I

R

E

TH

S T.

B

LD

G

B

S

TE

A

U S

TI

N

TE

X A

S

D A

T E

C

M E

T H

O D

A R

C H

IT

E

C T

U R

E

P L L C

C O

P Y

R

IG

H T

T H

E S

E D

R A

W

IN

G S

A R

E T

H E

P R

O P

E R

T Y

O F

M E

T H

O D

A R

C H

IT

E

C T

U R

E

L L C

A N

D M

A Y

N O

T B

E R

E P

R O

D U

C E

D

M O

D

IF

IE

D

N

O R

U S

E D

I N

A N

Y W

A Y

W

IT

H O

U T

T H

E

E X

P R

E S

S E

D W

R

IT

T E

N P

E R

M

IS

S

IO

N O

F M

E T

H O

D

A R

C H

IT

E

C T

U R

E

L L C

A R

A N

S A

S N

A T

IO

N

A L

W

IL

D L

IF

E

R E

F U

G E

A U

S T

W E

L L

T

X

A .0

.0

.2

M A

B U

N K

H O

U S E O

V E R

A

LL

F

LO

O R

P

LA

N

N

FLOOR PLAN KEYNOTES

A1 BUILD RESTROOM AS INDICATED - MUST CONFORM TO ALL REQUIREMENTS

OF THE IBC AND TAS STANDARDS

A2 PROVIDE 8'-4" LONG LOWER CABINETS WTIH OVEN, STOVE AND

VENTILATION HOOD. CABINETS TO COMPLY WITH ALL TAS REQUIREMENTS.

A3 PROVIDE WATER CONNECTION FOR TENANT PROVIDED WASHER AT NOTED

LOCATION. RE:MEP DRAWINGS FOR DETAILS

A4 PROVIDE WATER CONNECTION FOR TENANT PROVIDED REFRIDGERATOR.

RE: MEP DRAWINGS FOR DETAILS. TO COMPLY WITH ALL TAS

REQUIREMENTS.

A5 PROVIDE 7'-3" X 3'-0" KITCHEN ISLAND WITH BUILT IN DOUBLE SINK, AND

DISH WASHER AT NOTED LOCATION. TO COMPLY WITH ALL TAS

REQUIREMENTS

A9 PROVIDE CONNECTION FOR OWNER PROVIDED AND OWNER INSTALLED

DISHWASHER. RE: MEP DRAWINGS

3/16" = 1'-0"

BUNK HOUSE FLOORPLAN

ENVELOPE INFILTRATION REQUIREMENTS

BUILDING SHALL MEET ALL APPROPRIATE ENVELOPE INFILTRATION REQUIREMENTS

OF THE IEC, INCLUDING BUT NOT LIMITED TO:

ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING ENVELOPE SHALL BE

CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED.

MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION

RATES CERTIFIED BY THE MANUFACTURER.

FIRE CODE COMPLIANCE

OWNER SHALL PROVIDE PORTABLE FIRE EXTINGUISHER PER NFPA 10

FIRE ALARM PLANS AND SPECIFICATIONS SHALL BE PRESNTED FOR REVIEW AND

APPROVAL PRIOR TO SYSTEM INSTALLATION / ALTERATION

FIRE ALARM SIGNAL DEVICE PLAN AND SPECIFICATIONS SHALL BE PRESENTED

FOR REVIEW AND APPROVAL PRIOR TO SYSTEM INSTALL / ALTERATION AND WILL

BE CONNECTED TO BUILDING FIRE ALARM SYSTEM

FIRE ALARM AND DETECTION REQUIREMENTS - SPRINKLERED

MANUAL FIRE ALARM - SECTION 907.2

B: NOT REQUIRED FOR SPRINKLERED BUILDINGS WITH OCCUPANT NOTIFICATION

S: NOT REQUIRED

ALARM MONITORING

PROVIDE SYSTEM FOR MONITORING SPRINKLERS - SYSTEM TO COMPLY WITH NFPA 72

AUTOMATIC FIRE DETECTION SYSTEM - SECTION 907.2

A: NOT REQUIRED

B: NOT REQUIRED

OCCUPANT NOTIFICATION

PROVIDE SYSTEM FOR NOTIFYING OCCUPANTS - SYSTEM TO COMPLY WITH NFPA 72

FIRE-RESISTANCE RATING REQUIREMENTS

BUILDING ELEMENTS, HOURS (IBC TABLE 601)

TYPE IIB CONSTRUCTION

REQUIRED

RATING

(HOURS)

PRIMARY STRUCTURAL FRAME

BEARING WALLS - EXTERIOR

BEARING WALLS - INTERIOR

NONBEARING WALLS AND PARTITIONS - INTERIOR

FLOOR CONSTRUCTION / SECONDARY MEMBERS

ROOF CONSTRUCTION / SECONDARY MEMBERS

REQUIRED

RATING

(HOURS)

ELECTRICAL NOTES

REFERENCE ELECTRICAL DRAWINGS FOR POWER AND DATA LOCATIONS

FIRE EXTINGUISHER SCHEDULE

TAG COUNT MOUNT TYPE DESCRIPTION

N

TRUE PLAN GENERAL NOTES

.1

.2

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T

.0

.2

A S

I-

.0

.2

A S

I-

.0

.2

A S

I-

Bunk House Closet Door ModificationsDraft RFI https://app.procore.com//1034659/project/rfi/show/10212283 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/140276939 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/140276939 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798718 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798718 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798718 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798718 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/136612911 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/136612911 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/136612911 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/136612911 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/136612910 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798752 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798752 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798752 https://app.procore.com/1034659/project/drawing_areas/832149/drawing_log/132798752