The document is a Work Data Sheet specifying detailed requirements for a barbed wire fence repair project for the Davis Fire area. The fence specifications include a 4-wire configuration with 12-gauge barbed top and intermediate wires, and a 12-gauge smooth bottom wire, with precise wire spacing measurements ranging from 6" to 16" from ground level.
Specific technical details include line post spacing of 16 feet 6 inches, use of twisted steel stays centered between line posts, steel line posts (t-posts) that are 5 feet 6 inches long, and a post ground installation depth of 1 foot 6 inches. The project is associated with Solicitation Number 140L3925Q0047 and is being conducted by the Department of the Interior Bureau of Land Management's Nevada Region, focusing on fence repair in the Davis Fire area.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A06_Maps.pdf | ||
| A04_SOW.docx | DOCX document | |
| Sol_140L3925Q0047.pdf | ||
| B03_DBA_Wage_Determination.pdf | ||
| A06_Drawings.pdf | ||
| Bid_Schedule.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEQ CHAPTER \h \r 1WORK DATA SHEET
For
DAVIS FIRE FENCE REPAIR
BARBED WIRE FENCE
| Fence type: |
| Barbed Wire. |
Type of top wire:
12 ½ gauge barbed.
| Type of intermediate wires: |
| 12 ½ gauge barbed. |
| Type of bottom wire: |
| 12 ½ gauge barbless (smooth). |
Wire locations/dimensions in inches (typical spacing):
4-Wire Fence
| D: |
| 12" |
| C: |
| 8" |
| B: |
| 6" |
| A: |
| 16" |
(Wire “A” is measured from the ground up. Successive wires are measured from previous wire.)
| Line post spacing (L): |
| 16 feet 6 inches |
| Type of stays: |
| twisted steel. |
Stay spacing (l):
one stay centered between each line post
| Length of steel line posts (t-post)*: |
| 5 feet 6 inches. |
| Depth of steel line posts in ground (t-post): |
| 1 foot 6 inches. |