A06_NIFC_300-JWH_-_NICC_Plans.pdf
PDF 9 MB Posted
- Attached to
- NIFC 300 JWH MPR Suite Federal contract opportunity
- Solicitation number
- 140L3725R0004
About this file
These architectural and engineering plans document a renovation project for the National Interagency Fire Center (NIFC) 300-JWH NICC Suite located in Boise, Idaho. The comprehensive set of design drawings covers multiple disciplines including architectural, structural, mechanical, electrical, fire protection, and access control systems for a second-floor suite renovation.
The project involves comprehensive demolition and reconstruction of approximately 12,000 square feet of office space, including workspaces for Dispatch, Predictive Services, Break Room, and various office areas. Key design elements include new flooring, wall modifications, updated HVAC systems, electrical rewiring, lighting upgrades, access control modifications, and architectural finishes. The plans indicate the renovation will modernize the workspace while maintaining the existing building's structural integrity, with specific attention to safety standards, energy efficiency, and functional workspace design. Alternate bid options are included for certain renovation components, providing flexibility in implementation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L3725R0004_Amd_0005.pdf | ||
| Sol_140L3725R0004_Amd_0004.pdf | ||
| NIFC_300-JWH_NICC_Spec_R1_20250602_0003.pdf | ||
| NIFC_300-JWH_MPR_Drawings_R1_11x17_20250603_0003.pdf | ||
| NIFC_300-JWH_MPR_Specs_R1_20250602_0003.pdf | ||
| Sol_140L3725R0004_Amd_0003.pdf | ||
| NIFC_300-JWH_NICC_Drawings_R1_11x17_20250603_0003.pdf | ||
| Sol_140L3725R0004_Amd_0002.pdf | ||
| Sol_140L3725R0004_Amd_0001.pdf | ||
| Sol_140L3725R0004.pdf | ||
| B03_Wage_Determination_ID20250104_03-07-2025.pdf | ||
| B08_NIFC_300-JWH_-_Bid_Schedule_28FEB2025.pdf | ||
| SF1442_Example_Completion-Instructions-Reference.pdf | ||
| A06_NIFC_300-JWH_-_Supplemental_Info.pdf | ||
| A06_NIFC_300-JWH_-_MPR_Plans.pdf | ||
| A06_NIFC_300-JWH_-_NICC_Specs.pdf | ||
| A06_NIFC_300-JWH_-_MPR_Specs.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2 3 4 5 6 7 8 9 10 11 1312
F
G
H
I
J
K
L
M
R
T
U
V
W
2A
BREAK ROOM
DISPATCH
OFFICE
OFFICE
V
.I .F
8' - 10"
8' - 6"
3' - 4"
HUDDLE
V .I .F
OPEN OFFICE
11" 12' - 0" 5"
4 5
V .I .F
5' - 6" V.I.F OFFICE
V .I .F
V.I.F.
12' - 0"
B1
AE503A
TYP. C2
AE503A
TYP.
ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)
ROOM NAME AND NUMBER
WINDOW TYPE (SEE A600s)
KEYNOTE
DEMOLITION PLAN LEGEND
NAME
X
X
AREA OF WORK
LOCATION PLAN
1 2 3 4 5
D
C
B
A
S h e e t
T it le
D e s ig n e d b y
D ra w n b y
C h e c k e d b y
A p p ro v e d b y
R e v is io n s
U n it e d S ta te s D e p a rt m e n t o f th e I n te ri o r
B u re a u o f L a n d M a n a g e m e n t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
/9
/2
:3
:5
A
M C
U s e rs
\a lf o n s o ra m ir e z \D o c u m e n ts
R e v it L o c a lT e m p \L
B Y
D B
L M
T
O
N
IC
C a rc h a lf o n s o ra m ir e z .r v t
S E
C O
N D
F L O
O R
D E
M O
L
IT
IO
N
P L A
N
A R
A M
IR
E
Z
K E
D W
A R
D S
A R
A M
IR
E
Z
S R
O B
E R
T S
N
IF
C
-J
W H
N
IC
C S
U
IT
E R
E N
O V
A T
IO
N
N
IF
C C a m p u s S
D e v e lo p m e n t A v e B o is e
ID
140L0622D002
LBYDBLM23_TO16
09.03.2024
AD101A
N A
T
IO
N A
L I N
T E
R A
G E
N C
Y F
IR
E
C E
N T
E R
10 49
I S
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
A1
SECOND FLOOR DEMOLITION PLAN
# KEYNOTES
1 REMOVE CABINETS, COUNTERTOP, BACKSPLASH, AND SINK.
2 REMOVE DOOR AND FRAME TO ALLOW FOR NEW WALL INFILL.
3 DEMO WALL TO ALLOW FOR NEW DOOR IN THIS LOCATION.
4 DEMO WALL TO ALLOW FOR NEW WALL OPENING IN THIS
LOCATION.
5 DEMO PART WALL TO ALLOW FOR NEW STOREFRONT
WINDOWS IN THIS LOCATION.
6 DEMOLISH EXISTING HOLLOW METAL WINDOW UNIT, 12'-0" X
4'-0" V.I.F.
7 REMOVE ALL CARPET AND WALLBASE WITHIN ENTIRETY OF
ROOM NOTED.
8 BID ALTERNATE B: DEMOLISH EXISTING ALUMINUM WINDOW
SYSTEM 31'-4" X 4'-8" V.I.F.
9 DEMOLISH EXISTING FRAMED RAISED PLATFORM, 12" HIGH
(V.I.F.). PATCH AND REPAIR RAISED ACCESS FLOORING AS
REQUIRED, PREP TO RECIEVE NEW CARPET FLOORING.
11 BID ALTERNATE A: REMOVE ALL CARPET AND WALLBASE
WITHIN ENTIRETY OF ROOM NOTED.
12 BID ALTERNATE B: REMOVE EXISTING RAISED ACCESS
FLOORING TO ACCOMODATE NEW RAISED ACCESS RAMP. SEE
DETAILS ON SHEET AE502A FOR ADDITIONAL INFORMATION.
13 BID ALTERNATE B: REMOVE RAISED ACCESS FLOORING TO
THE FIRST FULL PANEL.
14 BID ALTERNATE B: DEMOLISH PORTION OF WALL TO
ACCOMODATE NEW RAISED ACCESS LANDING, SEE DETAIL ON
SHEET AE502A.
15 BID ALTERNATE B: DEMOLISH PORTION OF EXTERIOR
MASONRY WALL TO ACCOMODATE NEW PATIO OPENING, SEE
DETAIL ON SHEET AE502A.
16 BID ALTERNATE B: REMOVE AND REINSTALL 12"X12" SQUARE
OF INSULATION AT ALL GUARDRAIL BASE PLATE LOCATIONS.
TOTAL OF (9) SQUARES, SEE DETAIL C4/AE501A.
17 BID ALTERNATE B: REMOVE LAYER OF EXISTING EPDM
MEMBRANE AT PATIO AREA (12'X25'), EXISTING ROOF
INSULATION TO REMAIN. SEE DETAILS ON SHEET AE503A.
18 DEMO WALL TO ALLOW FOR NEW 6'-0"X8'-0" WALL OPENING IN
THIS LOCATION.
19 CUT EXISTING RAISED ACCESS FLOORING TO ACCOMODATE
NEW ELECTRICAL CONDUIT AND J-BOX, COORDINATE WITH
ELECTRICAL DRAWINGS AND NEW FURNITURE LAYOUT FOR
POWER REQUIREMENTS. VERIFY EXACT LOCATIONS IN FIELD
PRIOR TO CUTTING. REPLACE ACCESS FLOOR PANELS WITH
ABANDONED POWER/NETWORK PENETRATIONS, MATCH
EXISTING ACCESS FLOOR SYSTEM.
20 REMOVE EXISTING DOOR, DOOR FRAME TO REMAIN. PREP
DOOR FRAME TO RECEIVE NEW ACCESS CONTROL SYSTEM
AND DOOR HARDWARE. SEE SHEET A-601 FOR DOOR
HARDWARE AND ELECTRICAL DRAWINGS FOR FURTHER
REQUIREMENTS.
21 INFILL PIPE PENETRATION WITH PATCHING MORTAR AND
EPOXY BONDING AGENT (AS REQUIRED.), PREP FOR NEW
FLOOR FINISH. SEE PLUMBING DRAWINGS FOR FURTHER
REQUIREMENTS.
22 DEMOLISH EXISTING LAMINATE CLAD WINDOW SILL.
0 4' 8' 16'
N
D es cr ip tio n D at e
0%
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/0
3/
G
O V
'T R
E V
IE
W
C O
M M
E N
T S
/1
0/
WP#
RB1
P1
CP1
RB1
P1
CP1
RB1
P1
CP1
RB1
P1
CP1
RB1
P1
RT1
RB1
P1
CP1
RB1
P1
CP1
RB1
P1
CP1
RB1
P1
CP1
P5 P5
P5P5
DISPATCH
HUDDLE
PREDICTIVE
SERVICES
203B
PREDICTIVE
SERVICES
203C
BREAK ROOM
OFFICE
OFFICE
208A
OFFICE
208B
OFFICE
CG1
CG1
CG1
CG1
P1
RB1
CP1
P6
P
P
4 4
P
V.I.F
8' - 0"
V.I.
F4' -
V.I.F
4' - 0" V.I.F
4' - 0"
V.I.F
8' - 0"
V .I .F
V .I .F
V.I.F
18' - 0"
OPEN OFFICE
OFFICE
RB1
P1
CP1
LOCATION AND TYPE OF CORNER GUARDS#
FINISH PLAN LEGEND
ROOM NAME AND NUMBER
FLOOR FINISH 'RT1'
FLOOR FINISH 'CP1'
WALL PROTECTION LOCATION
A8## # INTERIOR ELEVATION CALLOUT AND DIRECTION OF
ELEVATION VIEW
NAME
AREA OF WORK
LOCATION PLAN
1 2 3 4 5
D
C
B
A
S h e e t
T it le
D e s ig n e d b y
D ra w n b y
C h e c k e d b y
A p p ro v e d b y
R e v is io n s
U n it e d S ta te s D e p a rt m e n t o f th e I n te ri o r
B u re a u o f L a n d M a n a g e m e n t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
/9
/2
:3
:5
A
M C
U s e rs
\a lf o n s o ra m ir e z \D o c u m e n ts
R e v it L o c a lT e m p \L
B Y
D B
L M
T
O
N
IC
C a rc h a lf o n s o ra m ir e z .r v t
S E
C O
N D
F L O
O R
F
IN
IS
H
P L A
N
A R
A M
IR
E
Z
K E
D W
A R
D S
A R
A M
IR
E
Z
S R
O B
E R
T S
N
IF
C
-J
W H
N
IC
C S
U
IT
E R
E N
O V
A T
IO
N
N
IF
C C a m p u s S
D e v e lo p m e n t A v e B o is e
ID
140L0622D002
LBYDBLM23_TO16
09.03.2024
IN101A
N A
T
IO
N A
L I N
T E
R A
G E
N C
Y F
IR
E
C E
N T
E R
22 49
I S
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
A1
SECOND FLOOR FINISH PLAN
# KEYNOTES
1 BID ALTERNATE A: PROVIDE NEW CARPET, WALL
BASE AND PAINT.
2 BID ALTERNATE B: CP1 TO RUN UP RAMP. PROVIDE
TRANSITION AT DOOR, LANDING, AND BASE OF
RAMP
3 WINDOW SILLS TO BE SS2, SEE DETAIL A1/AE502A.
4 WINDOW SILLS TO BE SS2, SEE DETAIL A4/AE502A.
0 4' 8' 16'
N
D es cr ip tio n D at e
0%
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/0
3/
G
O V
'T R
E V
IE
W
C O
M M
E N
T S
/1
0/
8/30/2024
Laura Rankin Digitally signed by Laura Rankin DN: CN=Laura Rankin, E=laurarankin@cushingterrell.com, G=Laura, SN=Rankin, C=US Reason: I agree to the terms defined by the placement of my signature on this document Contact Info: 208-577-5610 Date: 2024.08.30 14:10:38-06'00'
Digitally signed by Laura Rankin DN: CN=Laura Rankin, E=laurarankin@cushingterrell.com, G=Laura, SN=Rankin, C=US Reason: I agree to the terms defined by the placement of my signature on this document
Date: 2024.08.30 14:12:57-06'00'
Digitally signed by Laura Rankin DN: CN=Laura Rankin, E=laurarankin@cushingterrell.com, G=Laura, SN=Rankin, C=US Reason: I agree to the terms defined by the placement of my signature on this document
Date: 2024.08.30 14:13:05-06'00'
Digitally signed by Laura Rankin DN: CN=Laura Rankin, E=laurarankin@cushingterrell.com, G=Laura, SN=Rankin, C=US Reason: I agree to the terms defined by the placement of my signature on this document
Date: 2024.08.30 14:13:21-06'00'
P R O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
Date: 2024.09.03 16:02:44-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
16:03:00-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:07:30-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:07:39-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:07:46-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:07:59-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:08:03-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:08:09-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:08:13-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:08:18-06'00'
O
FE
SS
IONAL ENGINEER
NATHAN J. FRON
GN
ER
STATE OF IDA
HO
L I C E N S E D
18674
Digitally signed by Nathan Frongner, P.E.
14:08:25-06'00'
O
FE
SS
IONAL ENGINEER
MARIO AL HAD
DA
D
STATE OF IDA
HO
L I C E N S E D
2061470
R O
FE
SS
IONAL
L I C E N S
10/01/2024
O
FE
SS
IONAL ENGINEER
MARIO AL HAD
DA
D
STATE OF IDA
HO
L I C E N S E D
2061470
R O
FE
SS
IONAL
L I
O
FE
SS
IONAL ENGINEER
MARIO AL HAD
DA
D
STATE OF IDA
HO
L I C E N S E D
2061470
R O
FE
SS
IONAL
L I
O
FE
SS
IONAL ENGINEER
MARIO AL HAD
DA
D
STATE OF IDA
HO
L I C E N S E D
2061470
R O
FE
SS
IONAL
L I
O
FE
SS
IONAL ENGINEER
MARIO AL HAD
DA
D
STATE OF IDA
HO
L I C E N S E D
2061470
R O
FE
SS
IONAL
L I
O
FE
SS
IONAL ENGINEER
MARIO AL HAD
DA
D
STATE OF IDA
HO
L I C E N S E D
2061470
R O
FE
SS
IONAL
L I
| General |
| GI001A - COVER SHEET |
| GI002A - DRAWING INDEX AND GENERAL NOTES |
| GI100A - SECOND FLOOR CODE PLAN |
| Structural |
| S001A - GENERAL STRUCTURAL NOTES |
| SF101A - LOW ROOF FRAMING PLAN |
| S501A - STRUCTURAL DETAILS |
| S502A - STRUCTURAL DETAILS |
| Architectural |
| AD100A - FIRST FLOOR DEMOLITION PLAN |
| AD101A - SECOND FLOOR DEMOLITION PLAN |
| AD102A - FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN |
| AD103A - SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN |
| AE001A - ASSEMBLIES |
| AE100A - FIRST FLOOR PLAN |
| AE101A - SECOND FLOOR PLAN |
| AE102A - FIRST FLOOR REFLECTED CEILING PLAN |
| AE103A - SECOND FLOOR REFLECTED CEILING PLAN |
| AE501A - DETAILS |
| AE502A - WINDOW AND DOOR DETAILS |
| AE503A - ROOF DETAILS |
| AE601A - DOOR AND WINDOW SCHEDULES |
| IN100A - FIRST FLOOR FINISH PLAN |
| IN101A - SECOND FLOOR FINISH PLAN |
| IN201A - INTERIOR ELEVATIONS |
| IN601A - MATERIAL LIST |
| IF102A - SECOND FLOOR FURNITURE PLAN |
| Fire Protection |
| FP001A - FIRE PROTECTION, SITE PLAN, NOTES, LEGENDS, AND DETAILS |
| FD100A - FIRE PROTECTION FIRST FLOOR DEMOLITION PLAN |
| FD101A - FIRE PROTECTION SECOND FLOOR DEMOLITION PLAN |
| FP100A - FIRST FLOOR FIRE PROTECTION PLAN |
| FP101A - SECOND FLOOR FIRE PROTECTION PLAN |
| Plumbing |
| P101A - PLUMBING LEGEND DETAILS SCHEDULE |
| P102A - FIRST FLOOR PLUMBING DEMO / INSTALL |
| P103A - SECOND FLOOR PLUMBING DEMO / INSTALL |
| Mechanical |
| M001A - MECHANICAL LEGEND, NOTES AND ABBREVIATIONS |
| MD101A - SECOND FLOOR HVAC DEMOLITION PLAN |
| MD401A - SECOND FLOOR ENLARGED HVAC DEMOLITION PLANS |
| M101A - FIRST FLOOR HVAC PLAN |
| M102A - SECOND FLOOR HVAC PLAN |
| M401A - SECOND FLOOR ENLARGED HVAC PLANS |
| M501A - HVAC DETAILS |
| M502A - HVAC DETAILS |
| M503A - HVAC DETAILS |
| M601A - HVAC SCHEDULES |
| Electrical |
| E001A - ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS |
| ED101A - SECOND FLOOR DEMO PLAN |
| E101A - ELECTRICAL PLAN |
| E102A - ELECTRICAL LIGHTING PLAN |
| E501A - ELECTRICAL DETAILS |
| E601A - ELECTRICAL SCHEDULES |
File details come from the government source that posted it. Updated .