A06_40609261_GRTE-PMIS-312456_01-28-2022_Drawings_Final-CDs-R1.pdf
PDF 18 MB Posted
- Attached to
- GRTE GRANITE ENTRANCE STATION (VERTICAL) Federal contract opportunity
- Solicitation number
- 140P1423R0019
About this file
This solicitation is for vertical construction services for the Moose-Wilson Road Granite Entry Station in Grand Teton National Park. The solicitation seeks a contractor to complete vertical structures, mechanical systems, electrical systems, IT systems, and some additional amenities as part of Phase IB of the project. The construction must meet Accessibility Standards and is estimated to be valued between $500,000 and $1,000,000. Offerors must be registered in SAM and have current online Representations and Certifications. Proposals are due via email by the specified deadline. The procurement is set aside for small businesses with a NAICS code of 236220 and size standard of $45 million. The contract performance period is 10 days after NTP to 150 days after NTP. Pre-proposal questions must be submitted at least 7 days before the proposal deadline.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_1_Sign-in_Sheet_0001.pdf | ||
| Amendment_1_Questions_and_Answers_0001.docx | DOCX document | |
| Sol_140P1423R0019_Amd_0001.pdf | ||
| B08_40609261_Attachment_4_Past_Performance_Questionnaire.docx | DOCX document | |
| B03_40609261_Teton_County_Building_WY20230017_01272023.pdf | ||
| A06_40609261_MWR_Granite_Gate_Install_SOW.docx | DOCX document | |
| A06_40609261_MWR_Granite_Gate_Install_Plan_Sheets.docx | DOCX document | |
| Sol_140P1423R0019.pdf | ||
| B08_40609261_Attachment_1_Contract_Admin.docx | DOCX document | |
| B08_40609261_Attachment_3_General_References.pdf | ||
| B08_40609261_Attachment_5_Limitation_on_Subcontracting_Report.xlsx | XLSX spreadsheet | |
| B08_40609261_Attachment_2_Project_Experience_Form.docx | DOCX document | |
| A06_40609261_GRTE-PMIS-312456_01-28-2022_Specifications_Final-CDs-R1.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
OR
OR
Design (Title I)
Prepared in Accordance with Preliminary by Preliminary Design (Title I)
Construction Drawing Not Preceded
Approved by Superintendent on
Variance from Preliminary Design (Title I)
Project Manager
Drawing No.
Date
Date
QUALITY DESIGN CERTIFICATIONSheetMark REVISION Date Initial
STATEREGION COUNTY
LOCATION WITHIN PARK
NAME OF PARK
TITLE OF DRAWING DRAWING NO.
DEPARTMENT OF THE INTERIOR
UNITED STATES
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
PMIS
GOLDEN, CO 80401
ANDERSON HALLAS ARCHITECTS, PC
ARCHITECT
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 6:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
312456
312456
167343
1 43BASIC DATA: USGS TOPO MAP REVISED & REDRAWN 8/93. UPDATED 11/98. SGS.
INTERMOUNTAIN TETON WY
GRAND TETON NATIONAL PARK
DESIGN COMPONENTS OF MOOSE-WILSON RD
CONSTRUCTION DOCUMENTS
GRAND TETON NATIONAL PARK
GRANITE ENTRY STATION
3D VIEW SHOWN FOR VISUAL REFERENCE ONLY.
REFER TO PLANS AND DETAILS FOR ADDITIONAL
CONSTRUCTION INFORMATION.
N.T.S.
ISOMETRIC VIEW
GENERAL NOTES
1. DO NOT SCALE DRAWINGS
2. ALL WORK TO BE PERFORMED TO APPLICABLE BUILDING CODES (SEE LIST OF APPLICABLE CODES).
3. ALL DIMENSIONS ARE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED. ALL DIMENSIONS
INDICATING REQUIRED CLEARANCES ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH THE
CONTRACT DOCUMENTS, VERIFYING FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT
THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION.
CONTRACTOR SHALL NOTIFY CO IN WRITING OF ANY DISCREPANCY WITHIN THE CONTRACT
DOCUMENTS AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.
5. SHOULD THERE BE ANY QUESTIONS CONCERNING THE CONTRACT DOCUMENTS, EXISTING
CONDITIONS, AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE CO PRIOR TO PROCEEDING WITH THE WORK, OR RELATED WORK IN
QUESTION.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH THE PROJECT
SCOPE OF WORK, SCHEDULE, AND DEADLINES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ADVISING THE CO OF ALL ITEMS REQUIRING A LONG LEAD TIME UPON NOTICE TO PROCEED THAT WILL AFFECT THE SCHEDULE, AND SHALL SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES
FOR THE ITEMS IN QUESTION TO THE CO
7. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT WHERE THE CONTRACT
DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT
SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND
INSTALLED BY THE CONTRACTOR. THE CONTRACTOR SHALL FURNISH TO THE CO ALL
WARRANTIES AND GUARANTEES REQUIRED AT THE CONCLUSION OF THE PROJECT.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HOOK UPS / UTILITY CONNECTIONS, ETC. TO
TEMPORARY TRAILERS.
A4.0
A8.0
ROOM
250 SF
A9.0
A5.0
FIRST FLOOR
100'-0"
5 1 6 75
KEY NOTE WALL TYPE WINDOW
TYPE/
NUMBER
DOOR
NUMBER
ELEVATION
MARK NORTH ARROW
DETAIL
REFERENCE
BUILDING
SECTION
EXTERIOR
ELEVATION
INTERIOR
ELEVATION ROOM TAG
SYMBOLS
BLDG
NORTH
T R U E
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
OTS OPEN TO STRUCTURE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PLY PLYWOOD
PT PAINT
PTD PAINTED
QT QUARRY TILE
RAD RADIUS
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER TO or REFERENCE
REINF REINFORCED
RELOC RELOCATE(D)
REQ REQUIRED
REV REVISE, REVISED or REVISION
RM ROOM
RO ROUGH OPENING
RS ROUGH SAWN
(S) SEALANT
S SOUTH
SCHED SCHEDULE
SF SQUARE FEET
SHTG SHEATHING
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STN STAIN
STRUC STRUCTURE or STRUCTURAL
(T) TEMPERED
T&G TONGUE AND GROOVE
T.O. TOP OF
TD THRESHOLD
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VIN VINYL
VTR VENT THROUGH ROOF
W WEST
W/ WITH
W/O WITHOUT
WD WOOD
WIN WINDOW
EXT EXTERIOR
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FIN FINISH(ED)
FIXT FIXTURE
FLR FLOOR(ING)
FO FACE OF
FP FIRE PROTECTION
FRP FIBERGLASS REINFORCED
PANEL(ING)
FT FEET
FTG FOOTING
FURR FURRING
GA GAUGE OR GYPSUM
ASSOCIATION
GALV GALVANIZED
GC GENERAL CONTRACTOR
GD GRADE
GL GLASS or GLAZING
GND GROUND
GWB GYPSUM WALLBOARD
HM HOLLOW METAL
HAZMAT HAZARDOUS MATERIAL
HDR HEADER
HDW HARDWARE
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION and AIR
CONDITIONING
IBC INTERNATIONAL BUILDING
CODE
ID INSIDE DIAMETER
INFO INFORMATION
INS INSULATION or INSULATED
INT INTERIOR
JT JOINT
LAV LAVATORY
LIN LINOLEUM
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL and
PLUMBING
MFG MANUFACTURING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
<N> NEW
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO. NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
# POUND(S) or NUMBER
& AND
< ANGLE
@ AT
A/V AUDIO VISUAL
ABA ARCHITECTURAL BARRIERS
ACT
ABV ABOVE
ACM ASBESTOS CONTAINING
MATERIAL
ACT ACCOUSTICAL CEILING TILE
ADD ADDENDUM
ADJ ADJACENT or ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
APPROX APPROXIMATE(LY)
ARCH ARCHITECTURAL
ASPH ASPHALT
B.O. BOTTOM OF
BLDG BUILDING
BLKG BLOCKING
BR BACKER ROD
BTWN BETWEEN
C.O. CONTRACTING OFFICER
CAB CABINET
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTBB CEMENTITIOUS TILE BACKER
BOARD
CTR CENTER
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
DIAM DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
<E> EXISTING
E EAST
EA EACH
EG FOR EXAMPLE
ELEC ELECTRICAL
ELEV ELEVATION
EMER EMERGENCY
ENGR ENGINEER
EQ EQUAL
EQP EQUIPMENT
ETR EXISTING TO REMAIN
ABBREVIATIONS
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 6:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
G0.1
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 2 43
GENERAL
INFORMATION &
INDEX
ARCHITECTURAL
4 A1.0 FLOOR PLAN
5 A2.0 ROOF PLAN
6 A3.0 REFLECTED CEILING PLAN
7 A4.0 EXTERIOR ELEVATIONS
8 A5.0 BUILDING AND WALL SECTIONS
9 A5.1 WALL SECTIONS AND DETAILS
10 A6.0 SCHEDULES
11 A8.0 INTERIOR ELEVATIONS
12 A9.0 WINDOW DETAILS
13 A9.1 DOOR DETAILS
14 A9.2 FENCE DETAILS
15 A9.3 ROOF DETAILS
SHEET
SUB
SHEET SHEET NAME
GENERAL
1 G0.0 COVER SHEET
2 G0.1 GENERAL INFORMATION & INDEX
3 G0.2 CODE STUDY & WALL TYPES
INDEX
STRUCTURAL
16 S1.0 STRUCTURAL GENERAL NOTES
17 S2.0 WALL FRAMING PLAN
18 S2.1 ROOF FRAMING PLAN
19 S3.0 STRUCTURAL DETAILS
20 S3.1 STRUCTURAL DETAILS
MECHANICAL
21 MP0.0 MECHANICAL AND PLUMBING COVER SHEET
22 MP6.0 MECHANICAL AND PLUMBING SCHEDULES
23 M1.0 MECHANICAL DEMO PLAN
24 M1.1 MAIN BUILDING MECHANICAL NEW PLAN
25 M1.2 KIOSK MECHANICAL PLAN
26 M6.0 SEQUENCE OF OPERATIONS
PLUMBING
27 P1.0 PLUMBING PLAN
ELECTRICAL
28 E0.0 ELECTRICAL COVER SHEET
29 E0.1 ELECTRICAL GENERAL NOTES
30 E0.2 ELECTRICAL SITE PLAN
31 E1.0 ELECTRICAL POWER PLAN
32 E2.0 ELECTRICAL LIGHTING PLAN
33 E4.0 ELECTRICAL ONE-LINE DIAGRAM
34 E5.0 ELECTRICAL SCHEDULES
TECHNOLOGY
35 T0.0 TECHNOLOGY COVER SHEET
36 T0.1 TECHNOLOGY GENERAL NOTES
37 T0.2 TECHNOLOGY SITE PLAN
38 T1.0 TECHNOLOGY PLAN
39 T5.0 TECHNOLOGY SCHEDULES
40 T6.0 TECHNOLOGY DETAILS
41 T6.1 TECHNOLOGY DETAILS
42 T6.2 TECHNOLOGY DETAILS
43 T6.3 TECHNOLOGY DETAILS
LEGEND
EGRESS
PATH
DIRECTION OF
EGRESS TRAVEL
FIRE EXTINGUISHER
BRACKET
FEB
REQUIRED ACCESS OR
ACCESSIBILITY CLEARANCES
CODE ANALYSIS
2018 INTERNATIONAL BUILDING CODE WITH APPENDICES
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2020 NATIONAL ELECTRICAL CODE
2018 INTERNATIONAL FIRE CODE
INTERNATIONAL MECHANICAL CODE 2018
2018 INTERNATIONAL ENERGY CONSERVATION CODE
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
NPS SUSTAINABILITY GUIDELINES
BUILDING HEIGHT: 11' (MAX ALLOWABLE 40) PER
TABLE 504.3
NUMBER OF STORIES: 1 (MAX ALLOWABLE 2) PER TABLE
504.4
ALLOWABLE BUILDING AREA: 9,000 SF (TYPE VB, B OCCUPANCY)
PER TABLE 506.2
OCCUPANCY
B BUSINESS
CONSTRUCTION TYPE: VB, NOT SPRINKLED
BUILDING AREA
KIOSK 57 SF
OCCUPANT LOAD
BUSINESS 1 (57 SF/150)
FIRE EXTINGUISHERS REQUIRED PER SECTION 906, AND LOCATED
PER IFC TABLE 906.1
FIRE ALARM SYSTEM IS PROVIDED IN ACCORDANCE WITH 907.2.1
FIRE RATING: TYPE VB
PER TABLE 601 AND 602
IECC CODE ANALYSIS
OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE
METHOD PER TABLE C402.1.3
CLIMATE ZONE: 7
REQUIRED PROVIDED
ATTIC AND OTHER ROOFS R49 R50
WD FRAMED AND OTHER R20 + R3.8 CONTINUOUS R24 + R6 CONTINUOUS
UNHEATED SLAB ON GRADE R15 FOR 24" BELOW GRADE R15 ENTIRE SLAB AND
TO TOP OF FOOTING
BUILDING SEPARATION
TABLE 705.8 FIRE SEPARATION DISTANCE AND MAX AREA OF
EXTERIOR WALL OPENINGS: SEE EGRESS PLAN
ONLY ONE EXIT ACCESS DOOR PER BUILDING IS REQUIRED FOR THE
OCCUPANT LOAD IN ACCORDANCE WITH IBC 1015.1
NOTE: PREFABRICATED SHED IS ACCESSORY TO THE EXISTING
BUILDING (NONOCCUPIED) AND NOT PART OF THE CODE ANALYSIS.
WALL TYPES X
TYPE #
GRAPHIC
REPRESENTATION
1.0
/4
5/8" IMPACT RESISTANT GWB
5 1/2" WD FRAMING WITH 3-1/2" SPRAY
FOAM INSULATION
1" CONTINUOS RIGID INSULATION
7/8" GALV HAT CHANNEL FURRING AT 24"
OC (VERTICAL)
1X CEDAR CHANNEL LAP SIDING - STN
1/2" PLY SHEATHING
WEATHER BARRIER
EXT
INT
1.1
5/8" IMPACT RESISTANT GWB
3-1/2" WD FRAMING WITH FULL-DEPTH
ACOUSTIC BATT INSULATION
/4
COBBLE STONE VENEER, TAPERED FROM
3" AT TOP TO 6-1/2" AT GRADE
1" CONTINUOUS RIGID INSULATION
5/8" IMPACT RESISTANT GWB
5-1/2" WD FRAMING WITH 3-1/2" SPRAY FOAM
INSULATION
INT
EXT
/8
V A
R
IE
S
2.0
1-1/2" FULLY GROUTED CAVITY WITH MASONRY
TIES AT 16" OC ATTACHED THROUGH RIGID
INSULATION TO WD FRAMED WALL
1/2" PLY SHEATHING
WEATHER BARRIER
3/8" DRAINAGE MAT
KIOSK
FEE
COLLECTION
BREAK ROOM
RR
OUTBOUND
CHECK
REMIT
MECH
OFFICE
GENERAL
STORAGE
HALL
BIKE PATH
INBOUND LANE
INBOUND LANE
25% ALLOWABLE OPENINGS (UP,S)
18% ACTUAL
15% ALLOWABLE OPENINGS (UP,NS)
14.8% ACTUAL
IMAGINARY LOT LINE (SEE CODE ANALYSIS G0.1)
FEB
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 6:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
G0.2
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 3 43
CODE STUDY & WALL
TYPES
G0.2
EGRESS PLAN1
SCALE OF FEET
404 8 16
SCALE A
B L
D G
N O
R T
H
T R U E
SCALE A
<N> EXTERIOR WALL
WALL TYPE TAG,
REF: G0.1
WINDOW TYPE TAG, REF:
WINDOW SCHEDULE
DOOR TAG, REF:
DOOR SCHEDULE
LINE OF ROOF ABOVE
A4.0
A4.0
A5.0
A5.0
A5.0
A5.0
7 7
6 6
A5.0
A5.0
A5.0
A5.0
EQEQ
EQEQ
9' - 11 1/2"
/2 "7
/2
E Q
E Q
KIOSK
A
A
B
B
C
C
D
D
B.5
2.5
FEE
COLLECTION
BREAK ROOM
RR
OUTBOUND
CHECK
A4.0
A4.0
REMIT
MECH
OFFICE
GENERAL
STORAGE
HALL
106 101
116 120
/2
BIKE PATH
INBOUND LANE
INBOUND LANE
A8.0
A8.0
A8.0
A8.0
1.11.1
A9.2
A5.1
7' - 3" 5' - 6" 5' - 6" 5' - 6" 5' - 6"
5' - 6" 5' - 6" 5' - 6" 5' - 6"
1' - 3" 4' - 4 1/2" 2' - 10 1/2"
A9.2
1' - 10"
17' - 9"
A9.2
A5.1
/2
10' - 0" 4' - 0"
/8
2' - 6" 2' - 6"
108E
GENERAL NOTES
1. REFER TO SHEET G0.1 FOR WALL TYPES.
2. REFER TO SHEET A6.0 FOR WINDOW AND DOOR
ELEVATIONS.
3. DIMENSIONS ARE TO FACE OF STRUCTURE UON.
4. DOOR DIMENSIONS ARE TO CENTERLINE.
5. REFER TO STRUCTURAL, MECHANICAL, PLUMBING,
AND ELECTRICAL DRAWINGS FOR MORE
INFORMATION.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF1/
/2
1:
:5
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A1.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 4 43
FLOOR PLAN
KEYNOTES - FLOOR PLAN
101 INSTALL 10'X10' PREFABRICATED SHED ON <E> CONC
SLAB ON GRADE BY OTHERS (NIC). ANCHOR TO
FOUNDATION PER MANUFACTURER.
102 CONDENSATE DRAIN AND SPLASH BLOCK: REF. MECH.
103 WD SLAT FENCE WITH PREFINISHED MTL POSTS: REF.
A9.2.
106 OUTDOOR CONDENSING UNIT: REF. MECH.
108 18"X12" MECH CHASE: REF. MECH.
116 PROVIDE 30"X72" MOTORIZED ADJUSTABLE DESK;
BOD: EVODESK LIMITED; TOP: SQUARE RECYCLED
WOOD; BASE: CARBON BLACK
118 CONC LANDING BY OTHERS (NIC).
119 WD SLAT GATE WITH PREFINISHED MTL RAIL
CHANNELS AND HARDWARE, ATTACH TO WD POSTS:
REF. A9.2.
120 QUARTZ SILL WITH 6" SHELF EXTENSION ON HALF OF
WINDOW, REF TO 11/A8.0.
122 SITE IMPROVEMENTS BY OTHERS (NIC).
123 WALL-MOUNTED IT RACK: REF. TECH.
125 <E> ELEC PANEL: REF. ELEC.
126 <N> ELEC PANEL: REF. ELEC.
128 CONDUIT FOR KIOSK TO BE ROUTED TIGHT TO
CORNER: REF. ELEC.
132 LOCATION OF <N> BURIED PROPANE TANK: REF.
MECH.
133 LOCATION OF RELOCATED SECURITY EQUIPMENT:
REF. TECH.
139 PATCH WALL FINISH AS NEEDED AFTER WATER LINE
PROVIDED: REF. PLUMB.
140 PROVIDE BARRIER GATE OPERATOR BEYOND: REF.
1/E0.2.
142 FIRE EXTINGUISHER AND BRACKET.
143 PROVIDE <N> ROLLER SHADE AT <E> WINDOW.
144 PROVIDE <N> ROLLER SHADE AND SOLAR FILM AT <E>
WINDOW.
SCALE OF FEET
SCALE A
A1.0
FLOOR PLAN1
SCALE A
B L
D G
N O
R T
H
T R U
A4.0
A4.0
A5.0
A5.0
A5.0
A5.0
7 7
6 6
A5.0
A5.0
A5.0
A5.0
A B C D
B.5
2.5
A4.0
A4.0
16' - 8"
/2
2' - 6 1/2" 9' - 11 1/2" 4' - 2"
/2
A9.3
A9.3
LEGEND
<N> PREFINISHED
MTL STANDING SEAM
ROOFING
<E> CONC SHINGLE
ROOFING
PREFABRICATED
SHED MTL ROOFING
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 5:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A2.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 5 43
ROOF PLAN
SCALE OF FEET
SCALE A
A2.0
ROOF PLAN1
SCALE A
B L
D G
N O
R T
H
T R U E
KEYNOTES
101 INSTALL 10'X10' PREFABRICATED SHED ON <E> CONC SLAB
ON GRADE BY OTHERS (NIC). ANCHOR TO FOUNDATION PER
MANUFACTURER.
104 PREFINISHED MTL STANDING SEAM ROOFING.
1. ALL EXPOSED MECHANICAL DUCTWORK SHALL BE PAINTED, TYP.
2. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL DRAWINGS FOR MORE INFORMATION.
3. COORDINATE WITH STRUCTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL DRAWINGS FOR LOCATIONS OF CEILING FIXTURES.
<N> GWB CLNG: REF.
FINISH SCHEDULE
WALL MOUNTED
LUMINAIRE: REF. ELEC
<E> T&G
CLNG
<E> GWB
CLNG
SURFACE MOUNTED
EMERGENCY
LUMINAIRE: REF. ELEC
SUPPLY GRILLE: REF.
MECH
SURFACE MOUNTED
LUMINAIRE: REF. ELEC
<N> SECURITY
CAMERA: REF. TECH
<N> MTL SOFFIT
PANEL
WALL MOUNTED
EMERGENCY
LUMINAIRE: REF. ELEC
7 7
6 6
108' - 0"
KIOSK
A B C D
B.5
2.5
108' - 8"
108' - 8"
2' - 6 1/2" 9' - 11 1/2" 4' - 2"
16' - 8"
/2
/2
EXTENTS OF MTL
FLASHING CLEAT:
REF. A9.3
1' - 11 1/2" 5' - 2 1/2" 2' - 4 1/2"
E Q
E Q
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 5:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A3.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 6 43
REFLECTED CEILING
PLAN
SCALE OF FEET
SCALE A
SCALE AA3.0
REFLECTED CEILING PLAN1
KEYNOTES
107 WALL-MOUNTED FAN UNIT: REF. MECH.
108 18"X12" MECH CHASE: REF. MECH.
110 WALL MOUNTED COVE HEATER: REF. MECH.
111 CONDENSATE/REFRIGERANT PIPING: REF. MECH.
117 MECH DIFFUSER: REF. MECH.
124 SURFACE MOUNTED EMERGENCY LUMINAIRE: REF. ELEC.
128 CONDUIT FOR KIOSK TO BE ROUTED TIGHT TO CORNER: REF. ELEC.
129 STRUCTURAL 6"X6" WD KNEE BRACE, STN: REF. 4&5/A5.1 & STRUC.
B L
D G
N O
R T
H
T R U
A5.0
A B C DB.5
101129
114114
A5.0
7 6
A5.0
1' - 0" 7' - 7 1/2" 1' - 0"
129129
9' - 7 1/2"
A5.1
EQ EQ
A5.0
BC
4' - 2" 9' - 11 1/2" 2' - 6 1/2"
16' - 8"
GENERAL NOTES
1. REFER TO SHEET G0.1 FOR WALL TYPES.
2. REFER TO SHEET A6.0 FOR WINDOW AND DOOR
ELEVATIONS.
3. REFER TO STRUCTURAL, MECHANICAL,
PLUMBING, AND ELECTRICAL DRAWINGS FOR
MORE INFORMATION.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/3
0/
0:
:4
A
MB
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A4.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 7 43
EXTERIOR
ELEVATIONS
SCALE OF FEET
SCALE A
A4.0
SOUTH ELEVATION6
A4.0
KIOSK WEST ELEVATION1
KEYNOTES
119 WD SLAT GATE WITH PREFINISHED MTL RAIL CHANNELS AND HARDWARE, ATTACH
TO WD POSTS: REF. A9.2.
129 STRUCTURAL 6"X6" WD KNEE BRACE, STN: REF. 4&5/A5.1 & STRUC.
138 PREFINISHED MTL PLATE, TYP: REF. A9.0.
KEYNOTES
101 INSTALL 10'X10' PREFABRICATED SHED ON <E> CONC SLAB ON GRADE BY OTHERS
(NIC). ANCHOR TO FOUNDATION PER MANUFACTURER.
103 WD SLAT FENCE WITH PREFINISHED MTL POSTS: REF. A9.2.
104 PREFINISHED MTL STANDING SEAM ROOFING.
105 PRECAST STONE SILL: REF. 4/A9.0.
109 36"X16" RETURN-AIR LOUVER: REF. MECH.
114 COBBLE STONE VENEER BASE, TAPERED FROM 3" TO 6-1/2" AT BASE: REF. 3/A5.1.
115 WD CHANNEL LAP SIDING - STN.
A4.0
KIOSK EAST ELEVATION2
A4.0
KIOSK NORTH ELEVATION3
SCALE ASCALE ASCALE A
STATION FF
100' - 0"
T.O. EXISTING
FRAMING
108' - 8"
A5.03 5
T.O. STONE
103' - 3 1/2"
/2
A5.0B CB.5
/2
2' - 3 1/2"
STATION FF
100' - 0"
T.O. EXISTING
FRAMING
108' - 8"
A5.0 BC
T.O. STONE
103' - 3 1/2"
A8.0
A5.1
A8.0
2' - 6"
/8
STATION FF
100' - 0"
T.O. EXISTING
FRAMING
108' - 8"
7 6
A5.0
T.O. STONE
103' - 3 1/2"
A5.0
1 2
A9.3
A5.1
GENERAL NOTES
1. REFER TO SHEET G0.1 FOR WALL TYPES.
2. REFER TO SHEET A6.0 FOR WINDOW AND DOOR
ELEVATIONS.
3. DIMENSIONS ARE TO FACE OF STRUCTURE UON.
4. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL DRAWINGS FOR MORE INFORMATION.
CONC FOUNDATION
AND FOOTING BY
OTHERS (NIC): REF.
STRUC
CONC SLAB ON
GRADE BY OTHERS
(NIC): REF. STRUC
3-1/2" SPRAY FOAM
INSULATION
MTL CLAD WD
SLIDING SASH
WINDOW
5/8" GWB OVER 2X4
FRAMING
5/8" PLY SHEATHING
OVER 2X8
OVERFRAMING:
REF. STRUC
BASE AS
SCHEDULED: REF.
FINISH SCHEDULE
5/8" IMPACT
RESISTANT GWB
VAPOR RETARDER
BY OTHERS (NIC)
GRADE BY OTHERS
(NIC): REF. CIVIL
CONC CURB BY
OTHERS (NIC): REF.
CIVIL
A9.0
HIGH-HEAT
WATERPROOF
MEMBRANE OVER
ICE AND WATER
SHIELD - ENTIRE
ROOF
WALL MOUNTED
COVE HEATER: REF.
MECH
INSIDE MOUNT
ROLLER SHADES
WITH SOLAR SHADE
FABRIC, TYP ALL
WINDOWS
WEATHER BARRIER
2X TREATED STRUC
FASCIA: REF. STRUC
A9.3
1X CEDAR CHANNEL
SHIPLAP SIDING - STN
1X CEDAR FASCIA
BOARD - STN
7/8" GALV. HAT
CHANNEL FURRING
AT 24" OC (VERTICAL)
1" CONTINUOUS
RIGID INSULATION
5/8" GWB
PREFINISHED
MTL STANDING
SEAM ROOFING
FULL DEPTH SPRAY
FOAM INSULATION
EXPANSION JOINT
BY OTHERS (NIC)
LIQUID APPLIED
DAMPROOFING BY
OTHERS (NIC), TYP
R-15 MIN RIGID
INSULATION FROM
3" BELOW TOP OF
SLAB TO TOP OF
FOOTING BY
OTHERS (NIC)
R-15 MIN RIGID
INSULATION UNDER
ENTIRE SLAB BY
OTHERS (NIC)
1/2" PLY SHEATHING
OVER 2X6 FRAMING:
REF. STRUC
EPOXY BOLT: REF.
STRUC
MTL BASE FLASHING -
VERT LEG TO EXTEND
6" MIN UP WALL
BEHIND WEATHER
BARRIER
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 5:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A5.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 8 43
BUILDING AND WALL
SECTIONS
SCALE OF FEET
4202 6
SCALE A
A5.0
N/S SECTION AT FEE COLLECTION1
A5.0
E/W SECTION AT FEE COLLECTION2
A5.0
E/W SECTION AT KIOSK3
A5.0
N/S SECTION AT KIOSK4
KEYNOTES
104 PREFINISHED MTL STANDING SEAM ROOFING.
107 WALL-MOUNTED FAN UNIT: REF. MECH.
109 36"X16" RETURN-AIR LOUVER: REF. MECH.
110 WALL MOUNTED COVE HEATER: REF. MECH.
116 PROVIDE 30"X72" MOTORIZED ADJUSTABLE DESK; BOD:
EVODESK LIMITED; TOP: SQUARE RECYCLED WOOD; BASE:
CARBON BLACK
118 CONC LANDING BY OTHERS (NIC).
121 BASEBOARD HEATER: REF. MECH.
126 <N> ELEC PANEL: REF. ELEC.
129 STRUCTURAL 6"X6" WD KNEE BRACE, STN: REF. 4&5/A5.1 &
STRUC.
136 QUARTZ SHELF WITH HEAVY DUTY MTL BRACKETS, LOCATE
BRACKET TO ATTACH TO FRAMING OR PROVIDE BLOCKING
WITHIN WALL: REF. 12/A8.0.
A5.0
WALL SECTION AT KIOSK TRANSACTION WINDOW5
SCALE B
SCALE OF FEET
C
6X6 BEAM AND BRACE - STN,
PROVIDE SEALANT AT ALL JOINTS
AND PENETRATIONS: REF. STRUC
WEATHER BARRIER OVER 1/2"
PLY SHEATHING: REF. STRUC
1X CEDAR CHANNEL SHIPLAP
SIDING - STN
7/8" GALV. HAT CHANNEL
FURRING AT 24" OC (VERTICAL)
1" CONTINUOUS RIGID
INSULATION
5/8" PLY SHEATHING OVER 2X8
LVLS: REF. STRUC WITH FULL
DEPTH SPRAY FOAM INSULATION
HIGH-HEAT WATERPROOF
MEMBRANE OVER ICE AND WATER
SHIELD - ENTIRE ROOF
2X TREATED STRUC FASCIA: REF.
STRUC
1X CEDAR FASCIA BOARD - STN
PREFINISHED MTL STANDING SEAM
ROOFING
2X6 WD TRIM - STN. PROVIDE
SEALANT AT ALL JOINTS AND
PENETRATIONS
PRE-FINISH RAISED MTL SEAM
ROOF RAKE FLASHING
6X6 POST: REF.STRUC
3"
FACE OF STUD
3' - 8 1/2"
2X6 TREATED BLOCKING
EXTEND 2X6 WD TRIM BELOW
KNEE BRACE - STN. PROVIDE
SEALANT AT ALL JOINTS AND
PENETRATIONS
2"
MIN
1/2"
PRE-FINISHED RAISED MTL
FLASHING AND CLEAT, ANCHOR
WITH GALVANIZED FASTENERS
WITH NEOPRENE WASHER
B
COBBLE STONE VENEER,
TAPERED FROM 3" AT TOP TO
6-1/2" AT GRADE
1-1/2" FULLY GROUTED CAVITY
WITH MASONRY TIES AT 16" OC
ATTACHED THROUGH RIGID
INSULATION TO FRAMED WALL
DRAINAGE MAT
1" CONTINUOUS
RIGID INSULATION
5/8" IMPACT
RESISTANT GWB
2X6 WD FRAMING
WITH 3-1/2" SPRAY
FOAM INSULATION
1X CEDAR CHANNEL SHIPLAP
SIDING - STN, SCRIBE SIDING
TO STONES
WEATHER BARRIER
OVER 1/2" PLYWD
SHEATHING
7/8" GALV. HAT CHANNEL
FURRING AT 24" OC (VERTICAL)
BACKER ROD AND SEALANT
6 1/2"
PREFINISHED MTL FLASHING AT
MITERED SIDING CORNER, TYP
MTL DRIP EDGE WITH WEEP HOLES -
VERT LEG OF FLASHING TO EXTEND 6"
MIN UP WALL
1" FACED, CLOSED CELL RIGID
INSULATION, TAPE ALL JOINTS
COBBLE STONE VENEER, TAPERED
FROM 3" AT TOP TO 6.5" AT GRADE
WEATHER BARRIER OVER 1/2" PLYWD
SHEATHING: REF. STRUC
1 1/2" FULLY GROUTED CAVITY WITH
MASONRY TIES AT 16" OC ATTACHED
THROUGH RIGID INSULATION TO
FRAMED WALL
DRAINAGE MAT, EXTEND OVER MTL
FLASHING
GRADE BY OTHERS (NIC): REF. CIVIL
LIQUID APPLIED DAMPROOFING BY
OTHERS (NIC), TYP
REF. 4/A9.0 FOR WINDOW SILL DTL
12" X 18" MECH ACCESS DOOR:
REF. MECH
3 CM THICK QUARTZ SHELF WITH
BEAD EDGE OVER 3/4" PLYWD
1 1/2"
18"X12" MECH CHASE: REF. MECH
INSULATED RECTANGULAR MECH
DUCT: REF. MECH
INSULATED ROUND MECH DUCT:
REF. MECH
CONC SLAB ON GRADE BY OTHERS
(NIC): REF. STRUC
BASE AS SCHEDULED: REF. FINISH
SCHEDULE
5/8" IMPACT RESISTANT GWB, TYP
5/8" IMPACT RESISTANT GWB, TYP
2X WD BLOCKING AS REQUIRED
ACCESS PANEL IN DUCTWORK
WITHIN FOOTPRINT OF CHASE
ACCESS PANEL: REF. MECH
3 3/8" 1' - 6" 5 1/4"
7"
6"X6" BEAM AND BRACE, STN;
PROVIDE SEALANT AT ALL JOINTS
AND PENETRATIONS: REF. STRUC
2X6 WD TRIM, STN; PROVIDE
SEALANT AT ALL JOINTS AND
PENETRATIONS
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 5:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A5.1
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 9 43
WALL SECTIONS AND
DETAILS
SCALE A
SCALE OF FEET
1 0 1
SCALE B
A5.1
DTL AT KNEE BRACE5
A5.1
DTL AT STONE BASE CORNER1
A5.1
DTL AT BASE OF STONE VENEER3
SCALE OF INCH
606 3
SCALE A
SCALE B A5.1
DTL AT MECH CHASE2
N.T.S.
ISOMETRIC VIEW - KNEE BRACE
SCALE A
SCALE B
3D VIEW SHOWN FOR VISUAL
REFERENCE ONLY. REFER TO
PLANS AND DETAILS FOR
ADDITIONAL CONSTRUCTION INFO
WINDOW TYPES
TYPE A:
<N> SLIDING SASH
TYPE C:
<N> FIXED
TYPE D:
<N> PREFINISHED MTL
LOUVER: REF. MECH
5' - 0"
3' - 0"
TYPE B:
<N> SLIDING SASH
3' - 6"
5' - 0"
DOOR TYPES
TYPE A
HM DOOR
2" 3' - 0" 2"
3' - 4"
/2
" T
ROOM FINISH LEGEND
CT CERAMIC TILE
GWB GYPSUM WALL BOARD
PT PAINT
STN STAIN
RB RUBBER BASE
SF SHEET FLOORING
T&G WD TONGUE AND GROOVE, STAINED
1. CONTRACTOR TO PROVIDE 3/4" PLYWD PANEL SHUTTER AT WINDOW
TYPE B: REF. WINDOW DETAILS AND ELEVATIONS FOR ATTACHMENTS.
GENERAL NOTES
DOOR SCHEDULE
NUMBER FRAME TYPE
DOOR
TYPE
SIZE DETAILS
COMMENTSTHICKNESS WIDTH HEIGHT HEAD JAMB THRESHOLD
110 INSULATED HM A 1 3/4" 3' - 0" 7' - 0" 2/A9.1 1/A9.1 3/A9.1 TEMPERED GLASS AT GLAZED LIGHT
WINDOW SCHEDULE
NUMBER TYPE WIDTH HEIGHT HEAD DTL JAMB DTL SILL DTL COMMENTS
1 B 3' - 6" 4' - 0" 3/A9.0 2/A9.0 4/A9.0 PROVIDE <N> ROLLER SHADES
2 C 5' - 0" 4' - 0" 3/A9.0 2/A9.0 4/A9.0 PROVIDE <N> ROLLER SHADES
3 A 5' - 0" 4' - 6" 3/A9.0 2/A9.0 1/A9.0 PROVIDE <N> ROLLER SHADES
4 D 3' - 0" 1' - 4" PROVIDE MTL SCREEN AT INT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/3
0/
0:
:4
A
MB
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A6.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 10 43
SCHEDULES
ROOM FINISH SCHEDULE
NUMBER NAME
NEW/
EXISTING
FLOOR
FINISH
CEILING
FINISH
NORTH WALL EAST WALL SOUTH WALL WEST WALL
COMMENTSWALL FINISH BASE WALL FINISH BASE WALL FINISH BASE WALL FINISH BASE
101 OFFICE <E> <E> SF <E> T&G <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
102 OUTBOUND CHECK <E> <E> SF <E> GWB <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
103 GENERAL STORAGE <E> <E> SF <E> T&G <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
104 FEE COLLECTION <E> <E> SF <E> GWB <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
105 RR <E> <E> CT <E> <E> GWB, CT <E> <E> GWB, CT <E> <E> GWB, CT <E> <E> GWB, CT <E>
106 HALL <E> <E> SF <E> T&G <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
107 REMIT <E> <E> SF <E> T&G <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
108 BREAK ROOM <E> <E> SF <E> T&G <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
109 MECH <E> <E> SF <E> T&G <E> GWB <E> <E> GWB <E> <E> GWB <E> <E> GWB <E>
110 KIOSK <N> SF GWB-PT GWB-PT RB GWB-PT RB GWB-PT RB GWB-PT RB
SCALE OF FEET
2' - 10 3/4"
/2
2' - 3 1/2"
A5.0
8"
9"
A5.0
1' - 4"
1' - 11"
A8.0
2' - 6"2' - 2 1/2"
1' - 1"
A5.0
1' - 0" 1' - 0"
1' - 1 1/2" 4' - 10" 1' - 1 1/2"
A5.0
2' - 3"
1' - 4"
1' - 4"
1' - 8"
1' - 4" 1' - 4"
3' - 3"
9 1/2"
A5.1
LEGEND
<N> GWB - PT
<E> GWB
<E> CMU WITH
GWB FINISH
3 CM THICK
QUARTZ SHELF
WITH BEAD EDGE
MOTORIZED
ADJUSTABLE
WORK SURFACE
10 1/4"
7 1/2"
HEAVY DUTY MTL
SHELF BRACKETS
WITH VERTICAL
MOUNTING
FLANGE, LOCATE
TO ATTACH TO
FRAMING
3 CM THICK QUARTZ 6"
SHELF SILL EXTENSION
WITH BEAD EDGE ON
FIXED HALF OF CASEMENT
WINDOW, CONTINUOUS
WITH WINDOW SILL.
SUPPORT WITH HEAVY
DUTY SIDEWALL
COUNTERTOP SUPPORT
BRACKET
6"
3 CM THICK QUARTZ
WINDOW SILL, FLUSH WITH
WALL ON OPERABLE HALF
OF CASEMENT WINDOW
(CONTINUOUS WITH SHELF
EXTENSION BELOW)
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 5:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A8.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 11 43
INTERIOR
ELEVATIONS
SCALE OF FEET
4202 6
SCALE A
A8.0
MECH 109 EAST10
A8.0
MECH 109 SOUTH9
A8.0
REMIT 107 SOUTH8
A8.0
REMIT 107 WEST7
A8.0
FEE 104 WEST6
A8.0
FEE 104 NORTH5
A8.0
KIOSK 110 EAST4
A8.0
KIOSK 110 SOUTH3
A8.0
KIOSK 110 WEST2
A8.0
KIOSK 110 NORTH1
KEYNOTES
131 INSIDE MOUNT ROLLER SHADES WITH SOLAR
SHADE FABRIC.
134 QUARTZ COUNTERTOP: REF. 2/A5.1.
135 12" X 18" MECH ACCESS DOOR: REF. MECH.
136 QUARTZ SHELF WITH HEAVY DUTY MTL
BRACKETS, LOCATE BRACKET TO ATTACH TO
FRAMING OR PROVIDE BLOCKING WITHIN WALL:
REF. 12/A8.0.
141 14" DEEP HEAVY DUTY ADJUSTABLE SHELVING,
LOCATE BRACKET TO ATTACH TO FRAMING OR
PROVIDE BLOCKING WITHIN WALL.
142 FIRE EXTINGUISHER AND BRACKET.
KEYNOTES
107 WALL-MOUNTED FAN UNIT: REF. MECH.
110 WALL MOUNTED COVE HEATER: REF. MECH.
111 CONDENSATE/REFRIGERANT PIPING: REF. MECH.
116 PROVIDE 30"X72" MOTORIZED ADJUSTABLE DESK;
BOD: EVODESK LIMITED; TOP: SQUARE
RECYCLED WOOD; BASE: CARBON BLACK
120 QUARTZ SILL WITH 6" SHELF EXTENSION ON HALF
OF WINDOW, REF TO 11/A8.0.
121 BASEBOARD HEATER: REF. MECH.
123 WALL-MOUNTED IT RACK: REF. TECH.
126 <N> ELEC PANEL: REF. ELEC.
127 BASE AS SCHEDULED: REF. A6.0 FINISH
SCHEDULE.
128 CONDUIT FOR KIOSK TO BE ROUTED TIGHT TO
CORNER: REF. ELEC.
130 12" DEEP HEAVY DUTY ADJUSTABLE SHELVING,
LOCATE BRACKET TO ATTACH TO FRAMING OR
PROVIDE BLOCKING WITHIN WALL.
SCALE A SCALE A SCALE A SCALE A SCALE A SCALE A
SCALE B SCALE B SCALE B SCALE B
SCALE OF FEET
SCALE B
A8.0
DTL AT KIOSK WORKSTATION12
SCALE OF FEET
1 0 1
SCALE C
SCALE C A8.0
DTL AT TRANSACTION SILL11
SCALE C
1/2" AL REVEAL TRIM
5/8" IMPACT RESISTANT GWB
2X6 WD FRAMING WITH 3-1/2" SPRAY
FOAM INSULATION
1" CONTINUOUS RIGID INSULATION
3 CM SOLID SURFACE COUNTERTOP
WITH EASED EDGE
MTL CLAD WD SLIDING SASH WINDOW
PROVIDE 3/8" MIN BACKER ROD AND
SEALANT, TYP EA SIDE AND PROVIDE
TREATED WD SHIM
WALL JAMB BEYOND
PROVIDE 3/8" MIN BACKER ROD AND
SEALANT
SELF-ADHESIVE WEATHER MEMBRANE -
INSTALL FROM UNDER WINDOW SHIM TO
EXTEND 6" MIN DOWN (OVER SHEATHING)
1 3/4"
2X TREATED WD BUCK
EXTERIOR INTERIOR
GRID LINE
SELF-ADHESIVE WEATHER MEMBRANE -
WRAP AROUND INSIDE OF RO AND
EXTEND 6" MIN OF FACE OF SHEATHING
1X CEDAR CHANNEL SHIPLAP SIDING - STN
WEATHER BARRIER OVER PLYWD
SHEATHING EXTEND OVER BLOCKING
AND UNDER FLASHING
FLASHING TAPE
7/8" GALV. HAT CHANNEL FURRING AT 24"
OC (VERTICAL)
PROVIDE PRE-FINISHED MTL FLASHING - SET
IN BED OF SEALANT, SLOPE TO DRAIN
PROVIDE PRE-FINISHED MTL J-TYPE
FLASHING CLEAT - ANCHOR WITH SS LOW
PROFILE FASTENERS WITH NEOPRENE
WASHERS
PROVIDE 2X TREATED BLOCKING, SHIM AT
TOP TO PROVIDE SLOPE
PROVIDE 3/8" MIN BACKER ROD AND
SEALANT, TYP EA SIDE OF STOREFRONT
SYSTEM, PROVIDE TREATED WD SHIM
PROVIDE PRE-FINISHED MTL FLASHING -
SET IN BED OF SEALANT - ANCHOR WITH
SS LOW PROFILE FASTENERS WITH
NEOPRENE WASHER
1" CONTINUOUS RIGID INSULATION
WINDOW SILL BELOW
EXTERIOR
INTERIOR
SELF-ADHESIVE WEATHER MEMBRANE -
WRAP AROUND INSIDE OF RO AND EXTEND
6" MIN OF FACE OF SHEATHING
5/8" IMPACT RESISTANT GWB
2X6 WD FRAMING WITH 3-1/2" SPRAY FOAM
INSULATION
1X CEDAR CHANNEL SHIPLAP SIDING - STN
WEATHER BARRIER OVER PLYWD
SHEATHING EXTEND OVER BLOCKING
AND UNDER FLASHING
MTL CLAD WD WINDOW: REF. A6.0
WINDOW SCHEDULE FOR TYPE
GRID LINE
PROVIDE TREATED BLOCKING
FLASHING TAPE
7/8" GALV HAT CHANNEL FURRING AT 24"
OC (VERTICAL)
1/2" AL REVEAL TRIM
1X WD TRIM RETURN
SELF-ADHESIVE WEATHER MEMBRANE -
OVER WINDOW MOUNTING FLANGE TO
EXTEND 4" PAST FLANGE
NOTE: CONTRACTOR TO PROVIDE 3/4"
PLYWD PANEL SHUTTER AND MTL
PLATE ANCHORS AS INDICATED ON
ELEVATIONS AT WINDOW TYPE B.
AT WINDOW TYPE B: (2) PREFINISHED
MTL PLATES - ANCHOR WITH THREADED
ROD AND HEAVY DUTY CONC
ADHESIVE - PROVIDE NEOPRENE AND
GALVANIZED STL WASHER - PROVIDE
HOLE IN PLATES FOR WINTERIZATION
PANEL SECURING BOLT
PROVIDE 3/8" MIN BACKER ROD AND
SEALANT, AT WOOD / MTL CLAD WINDOW
SYSTEM, PROVIDE TREATED WD SHIM
1" CONTINUOUS RIGID INSULATION
WALL JAMB BEYOND
GRID LINE
EXTERIOR INTERIOR
SELF-ADHESIVE WEATHER MEMBRANE -
WRAP AROUND INSIDE OF RO AND
EXTEND 6" MIN ON FACE OF SHEATHING
BACKER ROD AND SEALANT
WEATHER BARRIER OVER PLYWD
SHEATHING EXTEND OVER BLOCKING
AND UNDER FLASHING
5/8" IMPACT RESISTANT GWB
2X6 WD FRAMING WITH 3-1/2" SPRAY
FOAM INSULATION
7/8" GALV HAT CHANNEL FURRING AT
24" OC (VERTICAL)
MTL CLAD WD WINDOW: REF. A6.0
WINDOW SCHEDULE FOR TYPE
PROVIDE PRE-FINISHED MTL
FLASHING WITH DRIP EDGE, SET IN
BED OF SEALANT, ANCHOR WITH SS
LOW PROFILE FASTENERS WITH
NEOPRENE WASHER
FLASHING TAPE
PROVIDE 2X TREATED BLOCKING, SHIM
AT TOP TO PROVIDE SLOPE
1X CEDAR CHANNEL SHIPLAP SIDING -
STN
PROVIDE 1X TREATED BLOCKING,
SHIM AT TOP TO PROVIDE SLOPE
SEALANT
SELF-ADHESIVE WEATHER MEMBRANE
OVER WINDOW MOUNTING FLANGE TO
EXTEND 4" PAST FLANGE
1X WD TRIM RETURN
1/2" AL REVEAL TRIM
/2
/2
VENT STRIP
1/2" AL REVEAL TRIM
5/8" IMPACT RESISTANT GWB
2X6 WD FRAMING WITH 3-1/2" SPRAY
FOAM INSULATION
1" FACED, CLOSED CELL RIGID
INSULATION, TAPE ALL JOINTS
COBBLE STONE VENEER, TAPERED
FROM 3" AT TOP TO 6.5" AT GRADE
3 CM SOLID SURFACE COUNTERTOP
WITH EASED EDGE
MTL CLAD WD WINDOW: REF. A6.0
WINDOW SCHEDULE FOR TYPE
PRECAST STONE SILL WITH KERF DRIP
EDGE
PROVIDE 3/8" MIN BACKER ROD AND
SEALANT, TYP EA SIDE AND PROVIDE
TREATED WD SHIM
WALL JAMB BEYOND
PROVIDE 3/8" MIN BACKER ROD AND
SEALANT
SELF-ADHESIVE WEATHER MEMBRANE -
INSTALL FROM UNDER WINDOW SHIM
TO EXTEND 6" MIN DOWN (OVER
SHEATHING)
SLOPE
PREFINISHED MTL FLASHING WITH DRIP
EDGE EXTEND UNDER SELF-ADHESIVE
MEMBRANE TO BTTM OF WINDOW
2X TREATED WD BUCK
EXTERIOR INTERIOR
GRID LINE
1 1/2" FULLY GROUTED CAVITY WITH
MASONRY TIES AT 16" OC ATTACHED
THROUGH RIGID INSULATION TO
FRAMED WALL
DRAINAGE MAT
MIN
1"
3"
6"
WEATHER BARRIER OVER PLYWD
SHEATHING
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/3
0/
0:
:4
A
MB
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A9.0
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 12 43
WINDOW DETAILS
SCALE OF INCH
606 3
SCALE A
A9.0
DTL AT TRANSACTION WINDOW SILL1
A9.0
DTL AT TYPICAL WINDOW JAMB2
A9.0
DTL AT TYPICAL WINDOW HEAD3
A9.0
DTL AT WINDOW SILL AT STONE4
HM FRAME - PT
EXTERIOR
INTERIOR
2X TREATED BUCK AROUND DR OPENING
TREATED WD SHIM
WEATHER BARRIER, EXTEND OVER
BLOCKING AND UNDER FLASHING
PROVIDE PRE-FINISHED MTL FLASHING CAP
HM INSULATED DR PANEL
PROVIDE 3/8" MIN. BACKER ROD AND
SEALANT - FILL ANY VOID WITH SEALANT
PROVIDE GALVANIZED CLEAT - ANCHOR
WITH STAINLESS STL FASTENERS WITH
NEOPRENE WASHER - CLEAT TO EXTEND
BEYOND HM FRAME
PROVIDE 2X TREATED BLOCKING
SELF-ADHESIVE WEATHER MEMBRANE -
WRAP AROUND INSIDE OF RO AND
EXTEND 6" MIN ON FACE OF SHEATHING
1" CONTINUOUS RIGID INSULATION
GRID LINE
1X CEDAR CHANNEL SHIPLAP SIDING -
STN
7/8" GALV HAT CHANNEL FURRING AT
24" OC (VERTICAL)
2X6 WD FRAMING WITH 3-1/2" SPRAY
FOAM INSULATION
5/8" IMPACT RESISTANT GWB
1/2" PLYWD SHEATHING: REF. STRUC
1" CONTINUOUS RIGID INSULATION
GRID LINE
2X6 WD FRAMING WITH 3-1/2"
SPRAY FOAM INSULATION
EXTERIORINTERIOR
1X CEDAR CHANNEL SHIPLAP SIDING - STN
7/8" GALV. HAT CHANNEL FURRING AT 24"
OC (VERTICAL)
HM INSULATED DR PANEL
PROVIDE 3/8" MIN. BACKER ROD AND
SEALANT - FILL ANY VOID WITH SEALANT
HM DOOR FRAME - PT
TREATED WD SHIM
SELF-ADHESIVE WEATHER
MEMBRANE - WRAP AROUND INSIDE
OF RO AND EXTEND 6" MIN ON FACE
OF SHEATHING
WEATHER BARRIER, EXTEND OVER
BLOCKING AND UNDER FLASHING
PROVIDE 1X TREATED BLOCKING - SHIM AT
TOP TO PROVIDE SLOPE
FLASHING TAPE
5/8" IMPACT RESISTANT GWB
PLYWD SHEATHING: REF/ STRUC
/2
VENT STRIP
PROVIDE GALVANIZED CLEAT, ANCHOR WITH
STAINLESS STL FASTENERS WITH NEOPRENE
WASHER, CLEAT TO EXTEND BEYOND HM
FRAME
PROVIDE PRE-FINISHED MTL FLASHING CAP
WITH DRIP EDGE, ANCHOR WITH SS
FASTENERS WITH NEOPRENE WASHER
PROVIDE 2X TREATED BLOCKING,
SHIM AT TOP TO PROVIDE SLOPE
HM DR FRAME BEYOND
HM INSULATED DR PANEL
AL THERMALLY-BROKEN THRESHOLD,
EXTEND ACROSS ISOLATION JOINT AT
INTERIOR SET IN SEALANT
CONC SLAB ON GRADE BY OTHERS (NIC)FLOOR FINISH AS
SCHEDULED: REF. A6.0
CONC FOUNDATION AND FOOTING: BY
OTHERS (NIC): REF. STRUC
VAPOR RETARDER AND RIGID
INSULATION BY OTHERS (NIC)
CONC SLAB ON GRADE BY
OTHERS (NIC)
EXTERIORINTERIOR
R-15 MIN RIGID INSULATION
FROM 3" BELOW TOP OF SLAB
BY OTHERS (NIC)
M A
X /2
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 5:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A9.1
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 13 43
DOOR DETAILS
A9.1
DTL AT DOOR JAMB IN EXT STUD WALL1
A9.1
DTL AT DOOR HEAD IN EXT STUD WALL2
SCALE OF INCH
606 3
SCALE A
A9.1
DTL AT DOOR THRESHOLD3
2X4 CEDAR SLATS
BOLTED TO STL
ANGLES, TYP
HSS 4X4X1/4 POST,
PROVIDE POWDER
COAT FINISH
4X4X3/8 STL ANGLE
BOLTED TO STL
TUBE, PROVIDE
POWDER COAT
FINISH
1" 1"
EQ EQ
10X10X5/8 STL
PLATE, PROVIDE
POWDER COAT
FINISH
5/8"X13" DIAM SS
EPOXY BOLTS
WITH WASHER
CLEAR
3' - 4"
A9.2
A9.2
A9.2
7 11
A9.2
7' - 3" 5' - 6"
CONC SIDEWALK BY OTHERS
(NIC)
HSS 4X4X1/4 POST
BEYOND, ANGLE TOP OF
POST TO PROVIDE SLOPE
AND CAP WITH WELDED
1/4" STL PLATE, PROVIDE
POWDER COAT FINISH
18" DIAM CONC FOOTING
TO 36" MIN DEPTH BY
OTHERS (NIC), TYP
4X4X3/8 STL ANGLE
BOLTED TO STL TUBE,
PROVIDE POWDER COAT
FINISH
10X10X5/8 STL PLATE,
PROVIDE POWDER COAT
FINISH
4X2X1/4 STL TUBE FRAME,
PROVIDE POWDER COAT
FINISH
2X4 CEDAR SLATS BOLTED TO
STL FRAME, POWDER COAT
FINISH, 1" GAP IN BETWEEN
MEMBERS, TYP
(4) BARREL HINGES PER
GATE, TYP
/2
/2
/8
LOCKING MECHANISM GATE
INTO CONC SLAB
A9.2
2X2X1/4 STL ANGLE WELDED
TO BOTTOM STL TUBE,
PROVIDE POWDER COAT
FINISH
MECH DUCT BY OTHERS (NIC)
1/4" STL PLATE WELDED TO
TUBE STL FRAME - BOTH
SIDES, FOR MOUNTING
OPERABLE GATE LATCHING
HARDWARE (OPERABLE PARTS
AT 34" MIN - 48" MAX AFF): REF.
SPECIFICATIONS
2X2X1/4 STL ANGLE GATE
STOP ATTACHED TO TUBE
STL, PROVIDE POWDER
COAT FINISH
A9.2
A9.2
CLEAR
6' - 0"
A9.2
A9.2
A9.2
2X4 CEDAR SLATS
BOLTED TO STL
ANGLES, TYP
HSS 4X4X1/4 POST,
PROVIDE POWDER
COAT FINISH
4X4X3/8 STL ANGLE
BOLTED TO STL
TUBE, PROVIDE
POWDER COAT
FINISH10X10X5/8 STL
PLATE, PROVIDE
POWDER COAT
FINISH
4X2X1/4 STL TUBE
FRAME, PROVIDE
POWDER COAT
FINISH
(4) BARREL HINGES
PER GATE, TYP
HOLD
2"
HSS 4X4X1/4 POST,
PROVIDE POWDER
COAT FINISH
4X4X3/8 STL ANGLE
BOLTED TO STL
TUBE, PROVIDE
POWDER COAT
FINISH
10X10X5/8 STL
PLATE, PROVIDE
POWDER COAT
FINISH
4X2X1/4 STL TUBE
FRAME, PROVIDE
POWDER COAT
FINISH
2X2X1/4 STL ANGLE
GATE STOP
ATTACHED TO
TUBE STL,
PROVIDE POWDER
COAT FINISH
1"
5/8"X13" DIAM SS
EPOXY BOLTS
WITH WASHER
CONC SIDEWALK BY
OTHERS (NIC)
2X4 CEDAR SLATS BOLTED TO STL
ANGLES, 1" GAP IN BETWEEN
MEMBERS, TYP
HSS 4X4X1/4 POST BEYOND,
ANGLE TOP OF POST TO PROVIDE
SLOPE AND CAP WITH WELDED
1/4" STL PLATE, PROVIDE POWDER
COAT FINISH
18" DIAM CONC FOOTING TO
36" MIN DEPTH BY OTHERS
(NIC), TYP
4X4X3/8 STL ANGLE BOLTED TO
STL TUBE, PROVIDE POWDER
COAT FINISH
10X10X5/8 STL PLATE, PROVIDE
POWDER COAT FINISH
(4) BARREL HINGES PER GATE,
TYP
MECH DUCT BY OTHERS
(NIC)
4X2X1/4 STL TUBE FRAME,
PROVIDE POWDER COAT FINISH
OPERABLE GATE LATCHING
HARDWARE (OPERABLE
PARTS AT 34" MIN - 48" MAX
AFF)
2X2X1/4 STL ANGLE WELDED
TO BOTTOM STL TUBE,
PROVIDE POWDER COAT
FINISH
2X2X1/4 STL ANGLE GATE
STOP ATTACHED TO TUBE
STL, PROVIDE POWDER
COAT FINISH
2' - 10 1/2" 4' - 4 1/2" 1' - 3"
CONC FOOTING TO 36" MIN DEPTH
BY OTHERS (NIC), TYP
/2
/2
/8
A9.2
/2
/2
4X2X1/4 STL TUBE FRAME, PROVIDE POWDER
COAT FINISH
2X4 CEDAR SLATS BOLTED TO STL FRAME,
POWDER COAT FINISH, 1" GAP IN BETWEEN
MEMBERS, TYP
HSS 4X4X1/4 POST BEYOND, ANGLE TOP OF
POST TO PROVIDE SLOPE AND CAP WITH
WELDED 1/4" STL PLATE, PROVIDE POWDER
COAT FINISH
2X2X1/4 STL ANGLE WELDED TO BOTTOM STL
TUBE, PROVIDE POWDER COAT FINISH
4X2X1/4 STL TUBE FRAME, PROVIDE POWDER
COAT FINISH
1/4" STL PLATE WELDED TO TUBE STL FRAME -
BOTH SIDES
OPERABLE GATE LATCHING HARDWARE
(OPERABLE PARTS AT 34" MIN - 48" MAX AFF):
REF. SPECIFICATIONS
/8
10X10X5/8 STL PLATE BEYOND
3/4" GROUT PAD BEYOND
A9.2
4X2X1/4 STL TUBE
FRAME, PROVIDE
POWDER COAT
FINISH
2X2X1/4 STL ANGLE
GATE STOP
ATTACHED TO
TUBE STL,
PROVIDE POWDER
COAT FINISH
2X4 CEDAR SLATS
BOLTED TO STL
ANGLES, TYP
4"
1"
HSS 4X4X1/4
POST, PROVIDE
POWDER COAT
FINISH
10X10X5/8 STL PLATE,
PROVIDE POWDER
COAT FINISH
3/4" GROUT PAD
5/8"X13" DIAM SS
EPOXY BOLTS
WITH WASHER 18" DIAM CONC
FOOTING TO 36" MIN
DEPTH BY OTHERS
(NIC), TYP
HSS 4X4X1/4
POST, PROVIDE
POWDER COAT
FINISH
10X10X5/8 STL
PLATE, PROVIDE
POWDER COAT
FINISH
3/4" GROUT PAD
5/8"X13" DIAM SS
EPOXY BOLTS
WITH WASHER
18" DIAM CONC
FOOTING TO 36" MIN
DEPTH BY OTHERS
(NIC), TYP
CONC SLAB BY
OTHERS, TYP
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 5:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A9.2
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 14 43
FENCE DETAILS
SCALE OF FEET
SCALE A
A9.2
DTL AT TYP FENCE POST3
A9.2
GATE PLAN - SOUTH9
A9.2
NORTH GATE AND FENCE ELEVATION10
SCALE OF FEET
1 0 1
SCALE B
SCALE B
SCALE B
SCALE A
A9.2
GATE PLAN - NORTH8
A9.2
DTL AT TYP GATE HINGE4
A9.2
DTL AT SOUTH GATE LATCH5
A9.2
SOUTH GATE AND FENCE ELEVATION7
A9.2
SECTION THROUGH TYP GATE1
SCALE B
SCALE B
SCALE A
SCALE A SCALE A
A9.2
DTL AT NORTH GATE LATCH6
SCALE B
A9.2
FENCE POST BASE DTL AT ISOLATED FOOTING2
SCALE B
A9.2
FENCE POST BASE DTL AT SLAB FOOTING11
SCALE B
PRE-FINISH RAISED MTL SEAM
ROOF RAKE FLASHING
PRE-FINISHED MTL RAKE Z
CLOSURE
5/8" TREATED PLYWD
SHEATHING
PRE-FINISHED RAISED MTL
FLASHING AND CLEAT, ANCHOR
WITH GALVANIZED FASTENERS
WITH NEOPRENE WASHER
PRE-FINISHED J-CHANNEL CLIP,
ANCHOR WITH GALVANIZED
FASTENERS WITH NEOPRENE
WASHER
2X TREATED STRUC FASCIA:
REF. STRUC
1X CEDAR FASCIA BOARD -
STN
ROOF MEMBRANE SPLICE
TAPE PREFINISHED MTL STANDING
SEAM ROOFING
HIGH-HEAT WATERPROOF
MEMBRANE, FROM BEHIND MTL
CLEAT
INSTALL LAYER ICE AND WATER
SHIELD ENTIRE ROOF; WRAP
UNDER CLEAT AND BEHIND
FASCIA BOARD AND OVER
BOTTOM FLASHING
5/8" PLYWD SHEATHING OVER 2X
OVERFRAMING: REF. STRUC
7/8" GALV. HAT CHANNEL
FURRING AT 24" OC (VERTICAL)
1X CEDAR CHANNEL LAP
SIDING - STN
R E
V E
A L
5/8" PLYWD SHEATHING OVER
2X8 LVL FRAMING WITH FULL
DEPTH SPRAY FOAM
INSULATION: REF. STRUC
FACE OF STUD
6 1/2"
/2
/2
1" CONTINUOUS RIGID
INSUALTION
WEATHER BARRIER, CONTINUE
OVER PLYWOOD SHEATHING
AND UNDER OVERFRAMING
FULL-DEPTH SPRAY FOAM
INSULATION
PRE-FINISHED MTL Z CLOSURE
CUT TO FIT, SET IN BUTYL TAPE
SEALANT AND FILL ANY VOIDS
WITH SEALANT
5/8" PLYWD OVER 2X WD
FRAMING: REF. STRUC
PREFINISHED MTL RIDGE
CAP
PREFINISHED MTL
STANDING SEAM ROOFING
HIGH-HEAT WATERPROOF
MEMBRANE
INSTALL LAYER ICE AND
WATER SHIELD ENTIRE ROOF
(2) 2X LVL RIDGE FRAMING: REF.
STRUC
MIN
2"
FASTENERS 16" OC WITH
BUTYL TAPE SEALANT
CAULK BETWEEN WEBS
7/8" GALV. HAT CHANNEL
FURRING AT 24" OC (VERTICAL)
1X CEDAR CHANNEL LAP SIDING -
STN
HIGH-HEAT WATERPROOF
MEMBRANE, FROM BEHIND
MTL CLEAT
PRE-FINISHED MTL SEAM ROOF
EVE CLOSURE FLASHING
PREFINISHED MTL STANDING
SEAM ROOFING
INSTALL LAYER ICE AND
WATER SHIELD ENTIRE ROOF;
WRAP UNDER CLEAT AND
BEHIND FASCIA BOARD AND
OVER BOTTOM FLASHING
ROOF MEMBRANE SPLICE TAPE
(1) LAYER SELF-ADHESIVE ROOF
MEMBRANE (OVER MTL
FLASHING) EXTEND ON TO
ROOF 12" MIN FROM EDGE OF
FLASHING
PRE-FINISHED J-CHANNEL CLIP,
ANCHOR WITH GALVANIZED
FASTENERS WITH NEOPRENE
WASHER
2X TREATED STRUC FASCIA:
REF. STRUC
1X CEDAR FASCIA BOARD - STN
1/2" TREATED PLYWD
SHEATHING
PRE-FINISHED RAISED MTL
FLASHING AND CLEAT, ANCHOR
WITH GALVANIZED FASTENERS
WITH NEOPRENE WASHER
5/8" PLYWD SHEATHING
OVER 2X LVL FRAMING: REF.
STRUC
FULL DEPTH SPRAY FOAM
INSULATION
FACE OF STUD
6 1/2"
/2
/2
MIN
6"
FULL-DEPTH SPRAY FOAM
INSULATION
5/8" PLYWD OVER 2X WD
FRAMING: REF. STRUC
CAULK BETWEEN WEBS
FILL PANEL HEM WITH BUTYL
SEALANT
FASTENER S 16" OC WITH
BUTYL TAPE SEALANT
HIGH-HEAT WATERPROOF
MEMBRANE
INSTALL LAYER ICE AND WATER
SHIELD ENTIRE ROOF
PREFINISHED MTL STANDING
SEAM ROOFING
PREFINISHED MTL VALLEY
FLASHING
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:3 6:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
-1
G
R T
E v
_B
IM
0.
rv t
A9.3
LB/BS
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
LB
BS/EH/BS
11/30/2021 15 43
ROOF DETAILS
SCALE OF FEET
1 0 1
SCALE A
A9.3
DTL AT TYP RAKE3
A9.3
DTL AT ROOF RIDGE2
A9.3
DTL AT TYP EAVE4
A9.3
DTL AT ROOF VALLEY1
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
S1.0
JR
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
JR
ASG
11/30/2021 16 43
STRUCTURAL
W1
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
W1
S3.0
B C
S2.0
JR
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
JR
ASG
17 43
WALL FRAMING PLAN
S3.0
11/30/2021
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
B C
S3.0
S3.0
S3.1
S3.0
S2.1
JR
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
JR
ASG
18 43
ROOF FRAMING PLAN
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
S3.0
JR
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
JR
ASG
19 43
STRUCTURAL
DETAILS
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
S3.1
JR
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
JR
ASG
20 43
STRUCTURAL
DETAILS
CHECK VALVE
2WAY ATC VALVE
3WAY ATC VALVE
BALANCING VALVE
BUTTERFLY VALVE
MECHANICAL LEGEND
PRESSURE REDUCING VALVE
EXISTING ITEMS TO
CONNECTION TO EXISTING
BE DEMOLISHED
EXISTING ITEMS
SAFTEY RELIEF VALVE
BACK FLOW PREVENTER
NEW WORK
PRESSURE SENSOR
THERMOSTAT
METER
P&T TAP
FLOW ARROW
IN LINE PUMP
THERMOMETER
AUTOMATIC AIR VENT
GAUGE
MANUAL AIR VENT
STRAINER
DRAIN VALVE
FLEXIBLE CONNECTION
UNION
CAP
PIPING SERVICES
PIPING SYSTEM COMPONENTS
TEE UP
TEE DOWN
RS/RL
CD
ELBOW DOWN
ELBOW UP
DRAWING NOTATION
CONDENSATE DRAIN
REFRIGERANT SUCTION/LIQUID GATE VALVE
PLUG VALVE
BALL VALVE
VALVES
ECCENTRIC REDUCER
HVAC SYSTEM COMPONENTS
MOTORIZED DAMPER
RECT. RETURN DUCT
RECT. SUPPLY DUCT
SUPPLY DIFFUSER/
DN
RETURN GRILLE
DUCT SLOPE
M
18x12 RECT.
12" ROUND
MANUAL DAMPER
(D) DEMO
(N) NEW
(E) EXISTING
THREE WAY CONTROL VALVE
M
T
P
(E) EXISTING
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
RS
RL
GRADE
SIGHT GLASS
FILTER DRYER
COND. DRAINTRAP
CONDENSING
UNIT
AC-1
NOTES:
-ROUTE REFRIGERANT PIPING PER MANUFACTURER REQUIREMENTS
-PROVIDE PVC SLEEVE FOR ALL REFRIGERANT PIPING BELOW GRADE
AND UP TO +/- 2" ABOVE GRADE.
CONCRETE PAD
W A
L L
STRUCTURE
AUXILIARY DRAIN PAN WITH UL 508
APPROVED WATER LEVEL DETECTION
DEVICE TO SHUTDOWN UNIT PRIOR TO
OVERFLOW
WALL-MOUNTED INDOOR AIR
CONDITIONING UNIT
SOLENOID VALVE (TYP.) WIRED TO AND
CONTROLLED BY UNIT CONTROLLER
SUPPLY LINE
SUMP OVERFLOW
N.C.
N.O.
N.O.
PROVIDE WITH THREADED END FOR YARD
HYDRANT TYPICAL GARDEN HOSE CONNECTION
GRADE
CONCRETE PAD
SUMP DRAIN PIPE TO BE PROVIDED SO THAT
DISCHARGE IS BEYOND CONCRETE PAD
SCALE: NOT TO SCALE
SPLIT SYSTEM DETAIL1
M1.0 SCALE: NOT TO SCALE
EVAPORATIVE COOLER AUTO DRAIN AND FILL DETAIL2
M1.0
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:4 7:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
G R
T E
M
P M od el
.r vt
MP0.0
BG
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
BG
TJR
11/30/2021 21 43
MECHANICAL AND
PLUMBING COVER
SHEET
GENERAL MECHANICAL NOTES
A. ALL WORK SHALL BE IN ACCORDANCE WITH SMACNA STANDARDS AND SPECIFICATIONS, AND AUTHORITY
HAVING JURISDICTION.
B. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND NOT INTENDED TO SHOW ALL TRANSITIONS, OFFSETS, ETC. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND PROVIDE ALL NECESSARY FITTINGS TO COMPLETE THE INTENT OF THE DRAWINGS. ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE CONTRACTING OFFICER (C.O). FOR RESOLUTION. CONTRACTOR MAY LOCATE MECHANICAL EQUIPMENT DIFFERENTLY THAN SHOWN ON DRAWINGS DUE TO CONFLICTS, AS LONG AS
FUNCTION AND/OR APPEARANCE ARE NOT AFFECTED.
C. MECHANICAL WORK SHOWN IS INDICATED DIAGRAMMATICALLY ON THE DRAWINGS. COORDINATE SPACE REQUIREMENTS, SUPPORTS, AND INSTALLATION OF MECHANICAL WORK PRIOR TO INSTALLATION. FOLLOW ROUTING SHOWN FOR PIPES AND DUCTS AS CLOSELY AS PRACTICABLE; PLACE RUNS PARALLEL WITH LINES OF BUILDING. UTILIZE SPACES EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER INSTALLATIONS, FOR
MAINTENANCE, AND FOR REPAIRS.
D. COMPLY WITH MANUFACTURER'S INSTRUCTIONS INCLUDING EACH STEP IN SEQUENCE. SHOULD MANUFACTURERS' INSTRUCTIONS CONFLICT WITH THE DRAWINGS REQUEST CLARIFICATION FROM THE C.O.
BEFORE PROCEEDING.
E. DUCT SIZES ARE INSIDE DIMENSION.
F. CONTRACTOR SHALL REVIEW THESE DOCUMENTS CAREFULLY. CONTRACTOR SHALL CONTACT C.O., FOR RESOLUTION OF ANY DISCREPANCIES, OMISSIONS, OR CLARIFICATIONS, BEFORE BID DATE. IN THE EVENT THAT AN INTERPRETATION OF BID DOCUMENTS IS NECESSARY AFTER THE BID DATE, THE DECISION OF THE C.O. SHALL
BE FINAL AND BINDING.
G. PRODUCT DELIVERY, STORAGE, AND HANDLING: PROVIDE EQUIPMENT AND PERSONNEL TO HANDLE PRODUCTS BY METHODS TO PREVENT DAMAGE. PROMPTLY INSPECT SHIPMENTS TO ENSURE THAT PRODUCTS ARE UNDAMAGED. STORE AND PROTECT PRODUCTS IN ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS.
H. IN THE CASE OF A CONFLICT, UNLESS OTHERWISE NOTED, KEYNOTES ON MECHANICAL PLANS SHALL
SUPERCEDE ANY GENERAL NOTES ON THE PLANS.
I. CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES AND NOTIFY THE C.O. IF ANY CONFLICTS
OCCUR.
J. THERMOSTAT LOCATIONS AND HEIGHTS TO BE COORDINATED AND VERIFIED BY THE C.O. CONTRACTOR TO CALIBRATE ALL THERMOSTATS SHOWN ON THIS PLAN. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL EXISTING THERMOSTATS REMAIN INTACT DURING DEMOLITION. HEATING THERMOSTATS MUST REMAIN OPERATIONAL AT ALL TIMES. IF REQUIRED FOR BETTER PROTECTION, THERMOSTATS MAY BE TEMPORARILY MOUNTED IN THE CEILING PLENUM DURING DEMOLITION.
K. ALL TAKEOFFS, RUNOUTS, AND FLEX DUCTWORK TO DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER
INLET UNLESS OTHERWISE NOTED.
GRILLES, REGISTERS, AND DIFFUSERS SCHEDULE
TAG
A
B
NOTES:
1.
2.
MANUFACTURER
PRICE
PRICE
PROVIDE WITH GYPSUM BOARD MOUNTING FRAME.
OPPSABLE BLADE DAMPER IN FACE OF GRILLE.
MODEL
AMCD
PFRF
SERVICE
SUPPLY
RETURN
MATERIAL
ALUMINUM
ALUMINUM
FACE SIZE
14x14
24x12
REMARKS
1,2
ELECTRIC HEAT SCHEDULE
GENERAL
TAG
ERH-1
EBB-1
NOTES:
1.
2.
3.
4.
MANUFACTURER
QMARK
QMARK
PROVIDE WITH WALL-MOUNTED LINE VOLTAGE THERMOSTAT.
PROVIDE WITH INTEGRAL ELECTRICAL DISCONNECT
PROVIDE WITH MANUFACTURER'S MOUNTING BRACKET AND HARDWARE
PROVIDE WITH NECESSARY EQUIPMENT TO ALLOW FLOOR MOUNTED INSTALLATION.
MODEL
RCC
QMKC
LOCATION
OVERHEAD
BASEBOARD
ARRANGEMENT
WALL-MOUNTED
FLOOR-MOUNTED
ELECTRICAL
VOLTAGE
[V]
PHASE
FREQ
[HZ]
60.0
60.0
POWER
[KW]
0.90
1.25
PHYSICAL
LENGTH
[IN]
WIDTH
[IN]
2-7/8
HEIGHT
[IN]
4-3/16
6-3/4
WEIGHT
[LBS]
15.5
REMARKS
1,2,3
1,2,4
SPLIT SYSTEM COOLING SCHEDULE
GENERAL
TAG
AC-1
CU-1
NOTES:
1.
2.
3.
4.
5.
6.
MANUFACTURER
MITSUBISHI
MITSUBISHI
PROVIDE WITH LOCAL THERMOSTAT FOR EQUIPMENT CONTROL.
PROVIDE WITH HAIL GUARDS.
PROVIDE WITH 120V MICROBLUE DIAMOND CONDENSATE PUMP WITH SENSOR AND RESERVOIR.
PROVIDE REFRIGERANT PIPING IN PVC SLEEVE WHEN ROUTED UNDERGROUND.
INSTALL ON 6" GRADE-MOUNTED CONCRETE PAD PROVIDED BY OTHERS.
PROVIDE AS SINGLE POINT POWER CONNECTION. INDOOR UNIT TO BE POWERED THROUGH OUTDOOR UNIT CONNECTION.
MODEL
PKA-A12HA7
PUY-A12NKA7
LOCATION
FEE COLLECTION
OUTDOOR
SUPPLY FAN (@ 7,000 FT)
TOTAL AIRFLOW
[CFM]
ESP
[IN WC]
N/A
N/A
DX COOLING (@ 7,000 FT)
REFRIG
R410A
R410A
SENSIBLE
MBH
9,240
9,240
ELECTRICAL
VOLTAGE
[V]
208/230
208/230
PHASE
FREQUENCY
[HZ]
60.0
60.0
MCA
[A]
1.0
11.0
MOCP
[A]
28.0
SEER
20.8
20.8
PHYSICAL
LENGTH
[IN]
35-3/8
31-7/8
WIDTH
[IN]
9-13/16
11-3/16
HEIGHT
[IN]
11-5/8
24-13/16
WEIGHT
[LBS]
NOTES
1,3,6
2,4,5,6
LOUVER SCHEDULE
GENERAL
TAG
L-1
NOTES:
1.
2.
3.
4.
MANUFACTURER
GREENHECK
PROVIDE WITH STAINLESS STEEL BIRDSCREEN.
PROVIDE WITH 2 COATS OF KYNAR PAINT AND MATCH COLOR TO EXTERIOR WALL.
PROVIDE WITH BAROMETRIC RELIEF DAMPER, MATCH LOUVER SIZE.
PROVIDE WITH EXTENDED SILL, FLANGED FRAME, AND WELDED CONSTRUCTION.
MODEL
ESD-403
LOCATION
KIOSK
SERVICE
RELIEF
PERFORMANCE
AIRFLOW
[CFM]
FREE AREA
[SF]
1.7
FACE VELOCITY
[FT/MIN]
PRESSURE DROP
[IN. W.C.]
0.08
PHYSICAL
HEIGHT
[IN]
WIDTH
[IN]
DEPTH
[IN]
NOTES
1,2,3,4
EVAPORATIVE COOLER SCHEDULE
GENERAL
TAG
EC-1
EC-2
NOTES:
1.
2.
3.
4.
5.
MFG
GREENHECK
GREENHECK
PROVIDE WITH 2" MERV 13 FILTER.
PROVIDE WITH FACTORY MOUNTED CONTROLS.
PROVIDE FACOTRY AUTHORIZED REP. START-UP.
UNIT IS COOLING ONLY.
PROVIDE WITH UNIT MOUNTED VFD.
MODEL
MSX-109-H12
DGX-P114-H12-MF
SERVICE
MAIN BUILDING
KIOSK
SUPPLY FAN (@ 7,000 FT)
TOTAL
[CFM]
OA
[CFM]
ESP
[IN. W.C.]
1.00
2.00
6.
7.
8.
9.
SPEED
[RPM]
PROVIDE WITH BOTTOM DISCHARGE.
PROVIDE WITH RECIRCULATING PUMP, AUTO DRAIN, AND FLUSH SEQUENCE.
PROVIDE WITH FIELD PROVIDED UNIT MOUNTED ELECTRICAL DISCONNECT.
PROVIDE WITH GRADE-MOUNTED CURB ON 6" CONCRETE PAD.
POWER
[BHP]
0.82
0.97
SIZE
[HP]
1-1/2
EVAPORATIVE COOLING (@ 7,000 FT)
EAT DB
[°F]
83.0
83.0
EAT WB
[°F]
54.3
54.3
LAT DB
[°F]
56.5
56.0
LAT WB
[°F]
54.3
54.3
GAS HEATING (@ 7,000 FT)
EAT DB
[°F]
-15.5
LAT DB
[°F]
70.0
10.
11.
12.
13.
INPUT
[MBH]
87.1
PROVIDE AS DIRECT GAS-FIRED HEATING.
PROVIDE WITH NECESSARY ACCESSORIES FOR PROPANE FUEL SOURCE.
PROVIDE WITH LINE VOLTAGE THERMOSTAT IN KIOSK FOR UNIT CONTROL
CONTROLLED BY EXISTING FURNACE THERMOSTAT.
OUTPUT
[MBH]
80.1
ELECTRICAL
VOLTAGE
[V]
PHASE
FREQ
[HZ]
60.0
60.0
MCA
[A]
13.7
11.2
MOCP
[A]
20.0
15.0
PHYSICAL
LENGTH
[IN]
82.76
104.89
WIDTH
[IN]
33.09
33.24
HEIGHT
[IN]
38.96
39.02
WEIGHT
[LBS]
NOTES
1,2,3,4,6,7,8,9,13
1,2,3,5,6,7,8,9,10,11,12
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:4 7:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
G R
T E
M
P M od el
.r vt
MP6.0
BG
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
BG
TJR
11/30/2021 22 43
MECHANICAL AND
PLUMBING
SCHEDULES
A B C D
B.5
2.5
FEE
COLLECTION
GENERAL
STORAGE
OFFICE
REMIT
MECH
BREAK ROOM
RR
OUTBOUND
CHECK
CORRIDOR
"x
(D) EVAPORATIVE
COOLER
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF11
/2
9/
:4 7:
P
M B
IM
-1
G
R T
E E nt ry
S ta tio n/
G R
T E
M
P M od el
.r vt
M1.0
BG
GRANITE ENTRANCE STATION
GRAND TETON NATIONAL PARK
167343
312456
BG
TJR
11/30/2021 23 43
MECHANICAL DEMO
PLAN
M1.0
MECHANICAL DEMO PLAN1
KEY NOTES:
EXISTING TO REMAIN UNCHANGED.
DEMOLITION AND REMOVAL OF EXISTING +/- 75' OF UNDERGROUND DUCTWORK FROM THIS
POINT BACK TO EXISTING EVAPORATIVE COOLER TO BE DONE BY OTHERS. DUCT STUB TO
REMAIN FOR NEW DUCT CONNECTION. OPEN END OF DUCT STUB TO BE CAPPED. SEE
SHEET M1.1 FOR NEW DUCTWORK CONNECTION.
DEMOLITION AND REMOVAL OF EXISTING EVAPORATIVE COOLER TO BE DONE BY OTHERS.
500-GALLON BURIED PROPANE TANK TO BE PROVIDED AND INSTALLED BY OTHERS.
SCALE OF FEET
8404 12
SCALE A
SCALE A
GENERAL NOTES:
1. CONTRACTOR TO MEASURE AND RECORD EXISTING SUPPLY AIRFLOWS AT EACH DIFFUSER.
DIFFUSERS TO BE BALANCED TO MATCH EXISTING AIRFLOWS.
2. THIS SHEET IS FOR REFERENCE ONLY. ALL DEMOLITION WORK IS TO BE DONE BY OTHERS.
B.5
2.5
"ø
"ø
FEE
COLLECTION
GENERAL
STORAGE
OFFICE
OUTBOUND
CHECK
RR
CORRIDOR
REMIT
MECH
BREAK ROOM
"x
20"ø
20"ø
16"ø
(N) AC-1
(N) CU-1
(N) EC-1
(N) EC-2
(E) BURIED
PROPANE TANK
RS/RL
3/4"…