A01 - 08(b) - PHC_CIP_2BR_Delta E.pdf
PDF 7 MB Posted
- Attached to
- PHC Housing Construction -Saipan Federal contract opportunity
- Solicitation number
- 70FBR922R00000004
About this file
This solicitation is for the construction of one to six housing projects located in Saipan, Commonwealth of the Northern Mariana Islands. The Federal Emergency Management Agency requires a contractor to provide all labor, materials, permits and equipment necessary to construct cast-in-place houses using government-provided designs and specifications. This will be a firm fixed price contract. The evaluation criteria and selection method will be specified in the solicitation. The requirement is set aside for small businesses currently licensed for residential construction in the CNMI. Phase one involves obtaining all designs and permits within 90 days, while phase two is the physical home construction with separate notices to proceed for each phase. A site visit will take place on July 29th and questions are due by August 2nd, with proposals due on August 8th. The government reserves the right to partially or fully not exercise the option during the period of performance.
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION ADA FEATURE
DOORBELL PUSHBUTTON
WATER CLOSET GRAB BAR
LAVATORY PLUMBING SHIELD
SHOWER GRAB BAR
SHOWER SEAT
ENTRY DOOR SWING OUT
RANGE AND REF LOCATIONS (SWITCHED)
SINK AND CABINET (KNEE SPACE)
WALL CABINET
RANGE HOOD SWITCH
CLOSET ROD AND SHELF (LOW MOUNTED HEIGHT)
VISUAL FIRE ALARM SYSTEMENTIRE
BEDROOM
BATHROOM
PEEP HOLE IN ENTRY DOOR
ENTRANCE
WORK COUNTER CABINET (KNEE SPACE)
KITCHEN
REF DWG
E-101A
A-401A
A-701A
A-401A
A-401A
A-101A
A-401A
A-401A
A-401A
E-101A
A-701A
FA-101A
A-601
A-401A
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N
O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
G-001
2BR
C O
V E
R S
H E
E T
D
R A
W
IN
G L
IS
T
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
B C
G
C J L
G C
K
C C
D
K A
B C
T
O
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
CODE INFORMATION
DRAWING LIST
NUMBER SHEET NAME REV
GENERAL
G-001 COVER SHEET & DRAWING LIST A, B, C, E
G-002 ABBREVIATIONS, LEGENDS, ARCHITECTURAL GENERAL NOTES
STRUCTURE
S-001 GENERAL STRUCTURAL NOTES, DESIGN LOADS & ABBREVIATIONS
S-002 GENERAL STRUCTURAL NOTES
S-003 TYPICAL STRUCTURAL DETAILS
S-004 TYPICAL FOUNDATION DETAILS A
S-005 TYPICAL SLAB ON GRADE AND FOOTING DETAILS
S-006 TYPICAL CONCRETE WALL DETAILS B, E
S-007 TYPICAL ELEVATED SLAB AND BEAM DETAILS E
S-101 FLOOR AND ROOF PLAN E
S-201 WALL ELEVATIONS E
S-301 BUILDING SECTIONS
S-311 WALL SECTIONS B
S-801 SPECIAL INSPECTION SPECIFICATIONS
ARCHITECTURE
A-101 2BR - FLOOR AND DIMENSION PLAN A, E
A-101A 2BR ADA - FLOOR AND DIMENSION PLAN A, E
A-102 2BR - ROOF AND REFLECTED CEILING PLAN A, E
A-201 2BR - EXTERIOR ELEVATIONS A, E
A-301 2BR - BUILDING AND WALL SECTIONS A, E
A-401 2BR - ENLARGED PLANS & INTERIOR ELEVATIONS A, B, E
A-401A 2BR ADA - ENLARGED PLANS & INTERIOR ELEVATIONS A, C, E
A-501 2BR - ROOF AND CONCRETE STOOP DETAILS D, E
A-601 2BR - DOORS, WINDOWS TYPES, SCHEDULES AND DETAILS B, E
A-602 2BR - FINISH FLOOR PLAN, FINISH SCHEDULE AND RESTROOM ACCESSORIES B, E
A-701 2BR - MILLWORK AND MISCELLANEOUS DETAILS A, E
A-701A 2BR ADA - MILLWORK AND MISCELLANEOUS DETAILS A, E
FIRE ALARM
FA-101 2BR - FIRE ALARM PLAN, FIRE PROTECTION SYMBOLS, NOTES E
FA-101A 2BR ADA - FIRE ALARM PLAN, FIRE PROTECTION SYMBOLS, NOTES E
MECHANICAL
M-001 MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS
M-002 PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS A
M-101 2BR - HVAC PLAN, NOTES, EQUIPMENT SCHEDULES, HVAC PIPING ISOMETRIC A, E
M-101A 2BR ADA - HVAC PLAN, NOTES, EQUIPMENT SCHEDULES, HVAC PIPING ISOMETRIC A, E
M-102 2BR - PLUMBING PLAN, NOTES, EQUIPMENT SCHEDULES A, E
M-102A 2BR ADA - PLUMBING PLAN, NOTES, EQUIPMENT SCHEDULES E
M-103 2BR - PLUMBING DOMESTIC WATER AND WASTE & VENT ISOMETRIC B
M-104 MECHANICAL & PLUMBING DETAILS
M-105 MECHANICAL & PLUMBING DETAILS B
ELECTRICAL
E-001 SYMBOLS LIST AND LIGHT FIXTURE SCHEDULE A
E-002 ELECTRICAL & TELECOMMUNICATION NOTES A
E-003 DETAILS
E-101 POWER PLANS A, E
E-101A POWER PLANS (ADA) A, E
E-102 LIGHTING & TELECOMMUNICATION PLAN A, E
E-601 ONE LINE DIAGRAM, PANEL SCHEDULE A
COUNT: 44
FEMA PERMANENT HOUSING
SAIPAN - 2 BEDROOM
CIP DESIGN COMPLETE
SAIPAN
1. BASE DESIGN REFLECTS REQUIREMENTS FOR NON-ADA LIVING UNITS.
2. ADA FEATURES FOR ADA LIVING UNITS ARE PROVIDED IN REPLACEMENT
SHEETS WITH SUBSEQUENT LETTER "A" AND/OR AS HIGHLIGHTED NOTES IN
A BOLDED RECTANGULAR BOX. REFER TO TABLE BELOW FOR RELATED
DRAWINGS.
BASE DESIGN AND ADA FEATURESLOCATION MAP
APPLICABLE BUILDING CODE: INTERNATIONAL BUILDING CODE (IBC) 2018
ENERGY CODE REQUIREMENT: CNMI TROPICAL ENERGY CODE (REVISED 2014)
CONSTRUCTION CLASSIFICATION: TYPE VB (MINIMUM)
OCCUPANCY CLASSIFICATION: RESIDENTIAL GROUP R-2
BUILDING AREA: 818 SQ.FT.
BUILDING STORY HEIGHT: 1
FIRE PROTECTION SYSTEM: NOT PROVIDED.
AUTOMATIC SPRINKLER SYSTEMS IS REQUIRED BY IBC 2018. HOWEVER, THE REQUIREMENT WAS WAIVED BY CNMI DEPARTMENT
OF FIRE AND EMERGENCY MEDICAL SERVICES.
ACCESSIBILITY REQUIREMENT FOR ADA UNITS: ADA FEATURES ARE IN COMPLIANCE WITH 2010 ADA STANDARD.
FLOOD RESISTANCE CONSTRUCTION: IF CONSTRUCTION SITE IS LOCATED WITHIN FLOOD HAZARD AREA, SITE CONSTRUCTION ENGINEER SHALL BE RESPONSIBLE FOR
BUILDING DESIGN TO COMPLY WITH IBC 2018.
This project was designed by the Honolulu District of the U.S. Army Corps of Engineers. The initials or signatures and registration designations of individuals appear on these project documents within the scope of their employment as required by ER 110-1-8152.
Approved by: _________________________________________________________________ Chief, Regional Engineering Center
Approved by: _________________________________________________________________ Chief, Engineering and Construction Division
DRAWING ABBREVIATIONS
A
A/C
AB
ACC
ACS
ACT
ADA
ADMIN
AFF
AGGR
AHU
ALT
ALUM
ANOD
APPROX
ARCH
ATC
AVG
AW
B
BB
BC
BD
BDRY
BFF
BHMA
BLDG
BLKG
BLT IN
BN
BOS
BOT
BP
BRKT
BSMT
BTWN
BUR
C
CAB
CD
CER
CF
CF/CI
CFE
CFLG
CFM
CFS
CG
CI
CIP
CJ
CL
CLG
CLG DIFF
CLG HT
CLO
CLR
CMU
CO
COL
COMM
CONC
CONF
CONT
COORD
CORR
CPT
CSWK
CT
CTR
CU FT
CW
D
D
DBL
DEMO
DEPT
DET
DIA
DIR
DIST
DOC
DR
DS
DWGS
E
EA
EIFS
EJ
ES
EL
ELEV
ENTR
EPS
EQ
EXP
EXT
F
FA
FAAP
FCO
FD
FDTN
FE
FEC
FED
FF
FF EL
FHP
FIN
FIN BS
FIN FLR
FIN GR
FIXT
FLEX
FLG
FLMT
FLR
FM
FOC
FR
FRMG
FRTW
FS
FSTNR
FT
FTG
G
GALV
GB
GFCI
GFGI
GLZ
GR FL
GYP BD
H
HB
HDPE
HDW
HDWD
HEPA
HM
HORIZ
HT
I
IBC
INSUL
INT
J
JAN
K
KIT
KPL
L
LAM
LAV
LBR
LBS
LF
LIB
LIN
LKR
LOC
LT
LVR
M
MACH RM
MANUF
MATL
MAX
MC
MECH
MEMB
MF
MFR
MID
MIL STD
MIN
MIRR
MISC
MLDG
MOD
MB
MTG
MTL
N
N
NA
NFPA
NIC
NO
NOM
NRC
NTS
O
OA
OC
OD
OFOI
OGL
OPH
OPNG
OPP
OPQ
OPR
ORD
ORIG
P
PA
PAT
PB
PCC
PCF
PCT
PERF
PERIM
PH
PL
PL GL
PLAM
PLAS
PLBG
PLYWD
PNL
PP PL
PR
PRKG
PSF
PSI
PTD
PTN
PWR
Q
QTY
R
RB
RBR
RCP
RD
REC
REC RM
REF
REM
REP
REPL
REQD
RESIL
REST
RF
RFG
RHR
RM
RO
S
SATC
SAPI
SCHED
SD
SF
SFTWD
SGL
SHT MTL
SIM
SJ
SLNT
SMK
SMLS
SP EL
SPEC
SQ
SQ IN
SQ YD
SST
ST
STD
STOR
STR
STRB/HRN
STRUC
SUSP
SUB FL
T
T
TEL
TEMP
TFF
THK
TK BD
TMPD GL
TOF
TOP
TOPO
TOS
TRANS
TRTD
TV
TYP
U
U.N.O
W
WP
AT
AIR CONDITIONING
ANCHOR BOLT
ACCESSIBLE
AUTOMATIC CONTROL SYSTEM
ACOUSTICAL CEILING TILE
AMERICANS WITH DISABILITIES ACT
ADMINISTRATION
ABOVE FINISHED FLOOR
AGGREGATE
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
ANODIZE
APPROXIMATE
ARCHITECT
ACOUSTICAL TILE CEILING
AVERAGE
ARCHITECTURAL WOODWORK
BASEBOARD
BOOKCASE
BOARD
BOUNDARY
BELOW FINISH FLOOR
BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BUILDING
BLOCKING
BUILT-IN
BULLNOSE
BOTTOM OF STEEL
BOTTOM
BUILDING PAPER
BRACKET
BASEMENT
BETWEEN
BUILT-UP ROOFING
CABINET
CONSTRUCTION DOCUMENTS
CERAMIC
CONTRACTOR FURNISHED
CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
CONTRACTOR FURNISHED
EQUIPMENT
COUNTERFLASHING
CUBIC FEET PER MINUTE
CUBIC FEET PER SECOND
CORNER GUARD
CAST IRON
CAST-IN-PLACE
CONTROL JOINT
CENTER LINE
CEILING
CEILING DIFFUSER
CEILING HEIGHT
CLOSET
COLOR
CONCRETE MASONRY UNIT
CLEANOUT
COLUMN
COMMUNICATION
CONCRETE
CONFERENCE
CONTINUE
COORDINATE
CORRIDOR
CARPET
CASEWORK
CERAMIC TILE
CENTER
CUBIC FEET
CASEMENT WINDOW
DEPTH
DOUBLE
DEMOLITION
DEPARTMENT
DETAIL
DIAMETER
DIRECTION
DISTANCE
DOCUMENT
DOOR
DOWNSPOUT
DRAWINGS
EACH
EXTERIOR INSULATION AND FINISH
SYSTEM
EXPANSION JOINT
EACH SIDE
ELEVATION
ELEVATOR
ENTRANCE
EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQUAL
EXPOSED
EXTERIOR, EXTINGUISHER
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FLOOR CLEANOUT
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FEDERAL
FINISH FACE
FINISH FLOOR ELEVATION
FULL HEIGHT PARTITION
FINISH
FINISH BOTH SIDES
FINISH FLOOR
FINISH GRADE
FIXTURE
FLEXIBLE
FLOORING
FLUSH MOUNT
FLOOR
FACTORY MUTUAL
FACE OF CONCRETE
FIRE RESISTANT
FRAMING
FIRE RETARDANT TREATED WOOD
FEDERAL SPECIFICATION
FASTENER
FEET
FOOTING
GALVANIZED
GRAB BAR
GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GOVERNMENT INSTALLED FURNISHED
INSTALLED BY GOVERNMENT
GLAZING
GROUND FLOOR
GYPSUM BOARD
HOSE BIBB
HIGH DENSITY POLYETHYLENE
HARDWARE
HARDWOOD
HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HOLLOW METAL
HORIZONTAL
HEIGHT
INTERNATIONAL BUILDING CODE
INSULATION
INTERIOR
JANITOR
KITCHEN
KICKPLATE
LAMINATE
LAVATORY
LUMBER
POUND
LINEAR FEET (FOOT)
LIBRARY
LINEAR
LOCKER
LOCATION
LIGHT
LOUVER
MACHINE ROOM
MANUFACTURER
MATERIAL
MAXIMUM
MOISTURE CONTENT
MECHANICAL
MEMBRANE
MILL FINISH
MANUFACTURER
MIDDLE
MILITARY STANDARD
MINIMUM, MINUTE
MIRROR
MISCELLANEOUS
MOLDING (MOULDING)
MODIFY
MOISTURE BARRIER
MOUNTING
METAL
NORTH
NOT APPLICABLE
NATIONAL FIRE PROTECTION
ASSOCIATION
NOT IN CONTRACT
NUMBER
NOMINAL
NOISE REDUCTION COEFFICIENT
NOT TO SCALE
OVERALL
ON CENTER
OUTSIDE DIAMETER
OWNER FURNISHED OWNER INSTALLED
OBSCURE GLASS
OPPOSITE HAND
OPENING
OPPOSITE
OPAQUE
OPERABLE
OVERFLOW ROOF DRAIN
ORIGINAL
PUBLIC ADDRESS
PATTERN
PULL BOX
PRECAST CONCRETE
POUNDS PER CUBIC FOOT
PERCENT
PERFORATED
PERIMETER
PHASE
PROPERTY LINE
PLATE GLASS
PLASTIC LAMINATE
PLASTER
PLUMBING
PLYWOOD
PANEL
PUSH/PULL PLATE
PAIR
PARKING
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PAPER TOWEL DISPENSER
PARTITION
POWER
QUANTITY
RESILIENT BASE
RUBBER
REFLECTED CEILING PLAN
ROOF DRAIN
RECESSED
RECREATION ROOM
REFERENCE, REFRIGERATOR
REMOVABLE
REPAIR
REPLACE
REQUIRED
RESILIENT
RESTROOM
RESILIENT FLOORING
ROOFING
RIGHT HAND REVERSE
ROOM
ROUGH OPENING
SUSPENDED ACOUSTIC TILE CEILING
SPRAY APPLIED POLYURETHANE INSULATION
SCHEDULE, SCHEDULED
SMOKE DETECTOR
SQUARE FOOT (FEET)
SOFTWOOD
SINGLE
SHEET METAL
SIMILAR
SCORED JOINT
SEALANT
SMOKE
SEAMLESS
SPOT ELEVATION
SPECIFICATION
SQUARE
SQUARE INCH
SQUARE YARD
STAINLESS STEEL
STAIRS
STANDARD
STORAGE
STRINGERS
STROBE/HORN
STRUCTURAL, STRUCTURE
SUSPENDED
SUBFLOOR
TREAD
TELEPHONE
TEMPORARY
TOP OF FINISH FLOOR
THICKNESS
TACKBOARD
TEMPERED GLASS
TOP OF FOOTING
TOP OF PARAPET
TOPOGRAPHY
TOP OF SLAB
TRANSOM
TREATED
TELEVISION
TYPICAL
UNLESS NOTED OTHERWISE
WATERPROOFING
LEGEND
ANNOTATION CALLOUTS/DRAWING SYMBOLS
ARCHITECTURAL GENERAL NOTES
DOOR NUMBER
CONC WALL, SEE STRUCTURAL SHEETS
FURRING PARTITION
DOOR
WINDOW
INSULATION
EARTH
POROUS
COMPACTED MATERIAL
101 WINDOW NUMBER
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS RELATING TO THE PROJECT BEFORE COMMENCING WITH THE REQUIRED WORK.
CONTRACTOR SHALL PROMPTLY NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES AND/OR CONDITIONS WHICH PREVENT HIM FROM FULFILLING THE
TERMS OF THE CONTRACT.
CONTRACTOR SHALL PATCH ALL SURFACES EXPOSED FROM CUTTING, AND/OR REMOVAL WORK. PATCHING SHALL MATCH THE FINISH OF THE ADJACENT SURFACES.
THE WORD "REPLACE" MEANS THAT THE CONTRACTOR SHALL REMOVE EXISTING WORK AND PROVIDE NEW WORK AS DETAILED OR NOTED ON THE DRAWINGS.
ALL WORK INDICATED SHALL BE NEW WORK UNLESS OTHERWISE INDICATED "EXISTING."
ALL ITEMS AND MATERIALS TO BE REMOVED SHALL BE DONE IN SUCH A MANNER AS TO PREVENT DAMAGE TO ITEMS AND MATERIALS TO REMAIN. ALL SUCH DAMAGES SHALL BE SATISFACTORILY REPAIRED AT NO ADDITIONAL COST TO THE GOVERNMENT.
ALL WASTE MATERIALS SHALL BE PROMPTLY REMOVED AND DISPOSED OF OUTSIDE THE LIMITS OF GOVERNMENT PROPERTY.
SEAL ALL JOINTS IN THE CONCRETE FLOOR AND ROOF SLABS, AND AROUND ALL PIPE AND CONDUIT PENETRATIONS.
VERIFY REQUIREMENTS OF EQUIPMENT WHERE RAISED CONCRETE PADS ARE INDICATED. ADJUST SIZE AS REQUIRED FOR EQUIPMENT PROVIDED. CONFIRM
LOCATIONS AND VERIFY REQUIREMENTS OF DEPRESSED SLABS.
REVISION TAG
NORTH ARROW w/
TRUE NORTH
INDICATION
ROOM TAG
ELEVATION NUMBER
SECTION
EXTERIOR ELEVATION
ENLARGEMENT,
DETAIL
WORKING POINT (WP)
SHEET NUMBER
SHEET NUMBER
INTERIOR ELEVATION
SHEET NUMBER
Room name
PLAN NORTH
A101
SIM
KEY TO
INTERIOR
ELEV
A
D B
C
A101
SIM
A-101
MATERIAL SYMBOLS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL DIMENSIONS SHOWN ON PLANS ARE TO FACE OF CONCRETE OR COLUMN CENTERLINES, UNLESS OTHERWISE NOTED.
ALL WALLS SHALL BE CENTERED ON CENTERLINES OF COLUMNS, CONCRETE MULLIONS, AND WINDOW MULLIONS UNLESS NOTED OTHERWISE.
THE 0'-0" REFERENCE ELEVATION SHALL BE THE TOP BLDG. FLOOR SLAB.
UNLESS OTHERWISE NOTED, ALL ELEVATIONS ARE MEASURED FROM THE REFERENCE ELEVATION + 0'-0".
VERIFY THE DIMENSIONS NECESSARY FOR PROPER EXECUTION OF THE WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF
THE CONTRACTING OFFICER REPRESENTATIVE.
UNLESS OTHERWISE NOTED, ALL NOTES, DETAILS AND FEATURES DRAWN AS APPLICABLE FOR ONE CONDITION, SHALL BE APPLICABLE TO SIMILAR
CONDITIONS WHETHER OR NOT IT IS SPECIFICALLY INDICATED OR NOTED.
INSTALL BLOCKING (STEEL STUD OR WOOD - TREATED WOOD NEAR WET CONDITIONS, U.N.O.) AT ALL WALL OR CEILING MOUNTED ACCESSORIES. VERIFY MOUNTING HEIGHTS WITH MANUFACTURER'S SPECIFICATIONS / RECOMMENDATIONS FOR EACH ITEM.
SEE ADDITONAL GENERAL NOTES ON EACH INDIVIDUAL SHEET
ALL GYPSUM BD IS TYPE "X" 5/8" THICK FOR WALL AND 1/2" THICK TYPE 'X" FOR CEILING UNLESS NOTED OTHERWISE.
THE CONTRACTOR SHALL VERIFY THE DIMENSIONS NECESSARY FOR PROPER EXECUTION OF THE WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
G-002
2BR
A B
B R
E V
IA
T
IO
N
S
L E
G E
N D
S
A R
C H
IT
E
C T
U R
A L
G E
N E
R A
L N
O T
E S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
B C
G
C J L
G C
K
C C
D
K A
B C
T
O
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
M
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-001
2BR
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
D
E S
IG
N
L O
A D
S
A B
B R
E V
IA
T
IO
N
S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
1. THE STRUCTURAL DESIGN AND CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING:
INTERNATIONAL BUILDING CODE (IBC) 2018
AMERICAN CONCRETE INSTITUTE (ACI) 318-14: BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE
AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) 7-16: MINIMUM DESIGN LOADS AND
ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES
DESIGN CRITERIA
2. FLOOR LIVE LOAD
A. RESIDENTIAL
3. ROOF LIVE LOAD:
4. SNOW LOADS
5. WIND DATA:
A. RISK CATEGORY:
B. BASIC DESIGN WIND SPEED, V:
C. NOMINAL WIND SPEED, Vasd:
D. EXPOSURE CATEGORY:
E. BUILDING ENCLOSURE CLASSIFICATION:
F. INTERNAL PRESSURE COEFFICIENT:
G. COMPONENTS AND CLADDING DESIGN WIND PRESSURE:
40 PSF
20 PSF
N/A
II
195 MPH
151 MPH
D
ENCLOSED
+/-0.18
VARIES, SEE A8/S-007
6. EARTHQUAKE DATA
A. MAPPED SPECTRAL ACCELERATIONS:
SHORT PERIOD, Ss:
1-SEC PERIOD, S1:
B. SPECTRAL RESPONSE COEFFICIENTS:
SHORT PERIOD, SDS:
1-SEC PERIOD, SD1:
C. SITE CLASS:
D. BASIC SEISMIC FORCE RESISTING SYSTEM:
SPECIAL REINFORCED CONCRETE SHEAR WALLS:
E. DESIGN BASE SHEAR:
F. SEISMIC RESPONSE COEFFICIENT, Cs:
G. ANALYSIS PROCEDURE:
1.78 g
0.45 g
1.66 g
0.47 g
D (ASSUMED)
R = 5 V = Cs X W 0.332
LINEAR STATIC
PROCEDURE
FOUNDATIONS
A.B.
ALT
APPROX
ARCH
BAL
BOT
BRG
CL
CIP
CJ
CLR
COL.
CONC
CONN
CONT
COORD
CSJ
CTRD
CWB
DCJ
DIA
DO
DWG
E.F.
E.W.
EA
EJ
EL
EQ
FTG
GA
GALV
GR.
GSN
HORIZ
I.A.W.
kN
KSI
LLH
LLV
LONG.
MAX
MECH'L
MFR
MIN
M.S.L.
MPa
N.S.F.M.
N.T.S.
OC
OPP
Pa
PL
PSI
PJF
REINF
SIM
SPA
STD
STL
THK
T.O.
TOC
TRANS
TYP
U.O.N.
VERT
W.W.M.
W.P.
ANCHOR BOLT
ALTERNATE
APPROXIMATELY
ARCHITECTURAL
BALANCE
BOTTOM
BEARING
CENTERLINE
CAST-IN-PLACE
CONTROL JOINT
CLEARANCE
COLUMN
CONCRETE
CONNECTION
CONTINUOUS
COORDINATE
CONSTRUCTION JOINT
CENTERED
CAPILLARY WATERBARRIER
DOWELED CONSTRUCTION JOINT
DIAMETER
DITTO (REPEAT)
DRAWING
EACH FACE
EACH WAY
EACH
EXPANSION JOINT
ELEVATION
EQUAL
FOOTING
GAGE
GALVANIZED
GRADE
GENERAL STRUCTURAL NOTE
HORIZONTAL
IN ACCORDANCE WITH
KILONEWTONS
KIPS PER SQUARE INCH
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONGITUDINAL
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
MEAN SEA LEVEL
MEGAPASCAL
NON-FROST SUSCEPTIBLE MATERIAL
NOT TO SCALE
ON CENTER
OPPOSITE
PASCAL
PLATE
POUNDS PER SQUARE INCH
PREMOLDED JOINT FILLER
REINFORCING
SIMILAR
SPACES
STANDARD
STEEL
THICK
TOP OF
TOP OF CONCRETE
TRANSVERSE
TYPICAL
UNLESS OTHERWISE NOTED
VERTICAL
WELDED WIRE MESH
WORK POINT
ABBREVIATIONS
1.REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60.
2.CLEAR CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED:
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:
B. CONCRETE FORMED AND EXPOSED TO EARTH OR WEATHER
#5 BAR AND SMALLER:
C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND
SLABS, WALL:
#11 BAR AND SMALLER:
BEAMS:
PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS:
3. REINFORCING STEEL SHALL BE SPLICED WHERE INDICATED ON PLANS. PROVIDE LAP SPLICE LENGTH PER
TYPICAL DETAILS AND SCHEDULE, UNLESS OTHERWISE NOTED.
4. MECHANICAL SPLICE CONNECTORS SHALL DEVELOP IN TENSON 125 PERCENT OF THE SPECIFIED MINIMUM
YIELD STRENGTH OF REINFORCING BARS.
5. STANDARD HOOKS ON REINFORCING BARS USED SHALL COMPLY WITH ACI SP-66.
6. MINIMUM REINFORCING BEND DIAMETERS SHALL COMPLY WITH ACI SP-66.
7. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS ARE TO BE SECURELY TIED IN PLACE BEFORE
CONCRETE IS POURED.
8. REINFORCING BAR BENDS SHALL BE MADE COLD.
9. REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE "ACI DETAILING
MANUAL - 2004" (SP-66) AS MODIFIED BY THE PROJECT DRAWINGS AND SPECIFICATIONS.
10.CONTRACTOR SHALL SUBMIT REINFORCING BAR LAYOUTS AND DETAILS FOR CONTRACTING OFFICER'S
REVIEW PRIOR TO FABRICATION. FABRICATE FROM REVIEWED DRAWINGS ONLY.
11. WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS OTHERWISE SHOWN ON THE DRAWINGS.
WELDING OF REINFORCING STEEL SHALL CONFORM TO AWS D1.4 "STRUCTURAL WELDING CODE -
REINFORCING STEEL" OF THE AMERICAN WELDING SOCIETY.
12. PROVIDE DOWELS TO MATCH REINFORCEMENT SIZE AND SPACING INDICATED FOR ALL STRUCTURAL
ELEMENTS UNLESS OTHERWISE INDICATED.
13. PROVIDE 2-#3 x 4'-0" DIAGONAL BARS IN THE MIDDLE OF THE SLAB AT EACH CORNER OF OPENINGS
LARGER THAN 12" AND AT RE-ENTRANT CORNERS.
REINFORCING STEEL
3"
2"
3/4"
1 1/2"
1.
2.
3.
4.
5.
6.
FOUNDATION DESIGN IS BASED ON THE ASSUMPTIONS BELOW. A GEOTECHNICAL INVESTIGATION IS TO BE CONDUCTED AT EACH SITE BY A LICENSED GEOTECHNICAL ENGINEER TO VALIDATE THE ASSUMED
GEOTECHNICAL DESIGN PARAMETERS.
ASSUMED GEOTECHNICAL DESIGN PARAMETERS ARE IN ACCORDANCE WITH TABLE 1806.2 OF IBC 2018:
A. ALLOWABLE BEARING PRESSURE
B. PASSIVE EARTH PRESSURE
SOIL BENEATH FOUNDATION SHALL BE SCARIFIED TO A DEPTH OF 6 INCHES, MOISTURE CONDITIONED
TO ABOVE THE OPTIMUM MOISTURE CONTENT, AND COMPACTED TO A MINIMUM OF 90% OF THE
MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557.
THE FOUNDATION SUBGRADE SHALL BE INPSECTED BY THE GEOTECHNICAL ENGINEER PRIOR TO
PLACEMENT OF REINFORCING STEEL AND CONCRETE TO VERIFY THE FOUNDATION BEARING
CONDITIONS.
SOFT AND/OR LOOSE SOILS SHALL BE OVER-EXCAVATED TO FIRM/DENSE SOILS AND BACKFILLED WITH ACCEPTABLE SELECT GRANULAR MATERIAL COMPACTED IN ACCORDANCE WITH THE SPECIFICATIONS.
PROVIDE 15 MIL VAPOR BARRIER UNDER ALL SLABS ON GRADE.
1,500 PSF
100 PSF/FT OF DEPTH
1.
2.
3.
4.
5.
6.
7.
8.
9.
GENERAL NOTES:
ALL MATERIALS AND WORKMANSHIP, DESIGN AND CONSTRUCTION SHALL CONFORM TO THE
DRAWINGS SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE 2018 EDITION.
THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE
METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE ALL
MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES
SHALL INCLUDE BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION
EQUIPMENT, WIND AND SEISMIC LOADING. ALL SHORING AND BRACING SYSTEMS SHALL BE
DESIGNED BY A LICENSED STRUCTURAL ENGINEER HIRED AND PAID FOR BY THE CONTRACTOR.
OBSERVATION VISITS TO THE SITE BY THE CONTRACTING OFFICER AND GOVERNMENT A/E SHALL
NOT INCLUDE INSPECTION OF THE ABOVE ITEMS NOR RELIEVE THE CONTRACTOR OF HIS/HER
OBLIGATIONS, DUTIES AND RESPONSIBILITIES.
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF
THE CONTRACTING OFFICER AND BE RESOLVED BEFORE PROCEEDING WITH THE WORK.
PRIOR TO FABRICATION, SHOP DRAWINGS REQUIRED BY THE SPECIFICATIONS SHALL BE REVIEWED
AND APPROVED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE CONTRACTING OFFICER.
SIZES AND LOCATIONS OF OPENINGS INDICATED ON DRAWINGS ARE FOR INFORMATION ONLY AND SHALL BE VERIFIED WITH THE APPROPRIATE DRAWING AND/OR SUPPLIER BEFORE CONSTRUCTION.
WHERE DISCREPANCIES, OMISSIONS AND/OR CONFLICTS ARISE BETWEEN DRAWINGS,
SPECIFICATIONS, BUILDING CODES, OR STANDARDS, CONTRACTOR SHALL PROVIDE WRITTEN
NOTIFICATION TO THE CONTRACTING OFFICER PRIOR TO PROCEEDING WITH ANY WORK INVOLVED.
DIMENSIONS SHALL NOT BE SCALED FROM THE PLANS, SECTIONS AND/OR DETAILS OF THE
STRUCTURAL DRAWINGS.
ARCHITECTURAL, MECHANICAL, AND ELECTRICAL COMPONENTS, SUPPORTS AND ATTACHMENTS
SHALL CONFORM WITH ASCE 7, CHAPTER 13. SEE DESIGN CRITERIA FOR SEISMIC DESIGN
CATEGORY. ISOLATORS, FASTENERS AND OTHER ELEMENTS PROVIDING STABILITY FOR
COMPONENTS SHALL BE APPROVED BY ICC OR EQUIVALENT TESTING PROCEDURES. PROVIDE
SUSPENDED EQUIPMENT WITH APPROVED LATERAL OR SWAY BRACING. SEE SPECIFICATIONS FOR
RESPONSIBILITY OF BRACING DESIGN.
SECONDARY STRUCTURAL MEMBERS NOT SHOWN IN THE CONTRACT DRAWINGS FOR THE
INSTALLATION OF NON-STRUCTURAL MATERIALS, EQUIPMENT OR COMPONENTS SHALL BE SPECIFIED IN THE SHOP DRAWINGS AND PROVIDED BY THE CONTRACTOR WITH NO ADDITIONAL COST TO THE
GOVERNMENT.
A.
B.
C.
D.
SEE ARCHITECTURAL DRAWINGS FOR SIZES AND LOCATIONS OF ALL FLOOR AND WALL
OPENINGS.
SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZES AND LOCATIONS OF ALL
OPENINGS REQUIRED FOR DUCTS, PIPES, AND PIPE SLEEVES.
OPENINGS OR POCKETS LARGER THAN 6 INCHES NOT INDICATED IN STRUCTURAL DRAWINGS
SHALL NOT BE PLACED WITHOUT WRITTEN NOTIFICATION TO THE CONTRACTING OFFICER.
CONDUITS AND PIPES TO BE EMBEDDED IN CONCRETE SHALL SATISFY THE REQUIREMENTS OF
ACI 318.
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-002
2BR
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
SPECIAL INSPECTION WORK AND MATERIAL TESTING SHALL BE ACCOMPLISHED AS PART OF
CONTRACTOR QUALITY CONTROL REQUIREMENTS. SEE DRAWING SHEET S-801 AND THE SPECIAL
INSPECTION AND MATERIAL TESTING SCHEDULES FOR REQUIRED ITEMS.
CONTRACTOR SHALL RETAIN ONE OR MORE SPECIAL INSPECTORS MEETING MINIMUM QUALIFICATIONS PER S-801 WHO SHALL PROVIDE INSPECTIONS DURING CONSTRUCTION FOR THE TYPES OF WORK
IDENTIFIED BY THE TABLES ON THIS DRAWING SHEET.
IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE AND SCHEDULE ALL
INSPECTIONS.
IT SHALL BE THE DUTY OF THE GENERAL CONTRACTOR TO HAVE THE AREA REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER THE SPECIAL INSPECTOR(S), NOR THE GOVERNMENT SHALL BE LIABLE FOR EXPENSES ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL
REQUIRED TO ALLOW INSPECTION.
THE SPECIAL INSPECTOR(S) SHALL SUBMIT A FINAL REPORT TO THE CONTRACTING OFFICER STATING
THE WORK REQUIRING SPECIAL INSPECTION WAS COMPLETED IN CONFORMANCE WITH THE
CONSTRUCTION DOCUMENTS.
REPRESENTATIVES OF THE CONTRACTING OFFICER CAN AND WILL INSPECT CONSTRUCTION AS
CONSIDERED APPROPRIATE AND WILL MONITOR OPERATIONS OF THE CONTRACTOR'S QUALITY
CONTROL STAFF. GOVERNMENT INSPECTION AND TESTING WILL NOT RELIEVE THE CONTRACTOR OF
ANY QUALITY CONTROL RESPONSIBILITIES.
SPECIAL INSPECTION
1. CONCRETE CONSTRUCTION SHALL CONFORM TO AMERICAN CONCRETE INSTITUTE ACI 318, ACI 301, ETC.
2. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE NORMAL WEIGHT HARD ROCK TYPE (150 lb/ft³) PORTLAND CEMENT AND SHALL CONFORM TO ASTM C-150 TYPE I OR II. CONCRETE MIXES SHALL BE DESIGNED BY A QUALIFIED TESTING LABORATORY AND SHALL BE SUBMITTED TO THE CONTRACTING OFFICER FOR REVIEW.
3. CONCRETE SHALL BE REGULAR WEIGHT HARD ROCK CONCRETE AND SHALL HAVE THE FOLLOWING MINIMUM
28 DAY COMPRESSIVE STRENGTHS:
A. SLAB ON GRADE:
B. WALLS, SUSPENDED SLABS & BEAMS:
C. ALL OTHER CONCRETE:
4. CONCRETE MIX DESIGN SUBMITTAL SHALL STATE LOCATION OF STRUCTURE WHERE MIX IS USED. MIX DESIGN
SHALL BE SUBMITTED TO CONTRACTING OFFICER FOR REVIEW PRIOR TO CONSTRUCTION.
5. WATER USED IN MIXING CONCRETE SHALL BE CLEAN AND FREE FROM INJURIOUS AMOUNTS OF OILS, ACIDS, ALKALIS, SALTS, ORGANIC MATERIALS OR OTHER SUBSTANCES THAT ARE DELETERIOUS TO CONCRETE OR
STEEL
REINFORCEMENT.
6. MAXIMUM AGGREGATE SIZE IN CONCRETE TOPPING AND RAMPS SHALL NOT EXCEED 3/8".
7. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN
POSITION PRIOR TO PLACING CONCRETE.
8. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY CONFLICT. CORING IN CONCRETE IS NOT PERMITTED EXCEPT AS SHOWN.
NOTIFY THE CONTRACTING OFFICER IN ADVANCE OF CONDITIONS NOT SHOWN ON THE DRAWINGS.
9. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE AN ARCHITECTURAL FINISH SHALL BE
APPROVED BY THE FINISH SUPPLIER BEFORE USE.
10. CONTRACTOR SHALL PROVIDE THE CONTRACTING OFFICER A SCHEDULE SPECIFYING CONCRETE POURS IN
UPCOMING THREE WEEKS.
11. CONCRETE ADMIXTURES CONTAINING CHLORIDE OR CHLORIDE SALTS SHALL NOT BE USED.
12. ALL ROUGHENED SURFACES IN CONCRETE SHALL BE MADE WITH A MINIMUM AMPLITUDE OF 1/4".
13. SEE ARCHITECTURAL DRAWINGS FOR CHAMFERS, EDGE RADII, DRIPS, REGLETS, FINISHES AND OTHER NON-
STRUCTURAL ITEMS NOT SHOWN OR SPECIFIED ON THE STRUCTURAL DRAWINGS.
14. NON-SHRINK GROUT SHALL BE A PREMIXED NON-METALLIC FORMULA, CAPABLE OF DEVELOPING A MINIMUM
COMPRESSIVE STRENGTH OF 3,000 PSI IN 1 DAY AND 5,000 PSI IN 28 DAYS.
15. LEAVE FORMWORK FOR BEAM SOFFITS, SLABS, AND OTHER STRUCTURAL ELEMENTS THAT SUPPORT WEIGHT OF CONCRETE IN PLACE UNTIL CONCRETE HAS ACHIEVED ITS 28 DAY DESIGN COMPRESSIVE STRENGTH.
16. CONSTRUCTION JOINT LOCATIONS MUST BE APPROVED BY THE CONTRACTING OFFICER.
17. EPOXY ADHESIVE SHALL BE SIMPSON SET-XP, HILTI HIT HIT-RE 500-SD, DEWALT PURE 100+, OR APPROVED EQUAL. ADHESIVE SHALL MEET ASTM C881 AND HAVE AN ULTIMATE TENSILE STRENGTH OF 48 KSI (#5 9"
EMBEDMENT).
CONCRETE
f'c = 4,000 PSI f'c = 4,000 PSI f'c = 4,000 PSI
1.
2.
3.
4.
5.
6.
SCHEDULE OF SPECIAL INSPECTIONS
OBSERVE THESE ITEMS RANDOMLY DURING THE COURSE OF EACH WORK DAY TO INSURE THAT
APPLICABLE REQUIREMENTS ARE BEING MET. OPERATIONS NEED NOT BE DELAYED PENDING THESE
INSPECTIONS AT CONTRACTOR’S RISK.
DOCUMENT, WITH A REPORT, THAT THE WORK HAS BEEN PERFORMED IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS. THIS IS IN ADDITION TO ANY OTHER REPORTS REQUIRED IN THE SPECIAL
INSPECTIONS GUIDE SPECIFICATION.
CONSTANT MONITORING OF IDENTIFIED TASKS BY A SPECIAL INSPECTOR OVER THE DURATION OF
PERFORMANCE OF SAID TASKS.
OBSERVE:
DOCUMENT:
CONTINUOUS:
INSPECTION DEFINITIONS:
CONCRETE CONSTRUCTION, INCLUDING COMPOSITE DECK – VERIFY THE FOLLOWING ARE IN COMPLIANCE
IBC TABLE 1705.3 (ACI 318 REFERENCES NOTED IN IBC TABLE)
TASK INSPECTION
TYPE
DESCRIPTION
1. INSPECT
REINFORCEMENT,
INCLUDING
PRESTRESSING
TENDONS, AND VERIFY
PLACEMENT.
OBSERVE VERIFY PRIOR TO PLACING CONCRETE THAT REINFORCING
IS OF SPECIFIED TYPE, GRADE AND SIZE; THAT IT IS FREE OF
OIL, DIRT AND UNACCEPTABLE RUST; THAT IT IS LOCATED
AND SPACED PROPERLY; THAT HOOKS, BENDS, TIES,
STIRRUPS AND SUPPLEMENTAL REINFORCEMENT ARE
PLACED CORRECTLY; THAT LAP LENGTHS, STAGGER AND
OFFSETS ARE PROVIDED; AND THAT ALL MECHANICAL
CONNECTIONS ARE INSTALLED PER THE MANUFACTURER’S
INSTRUCTIONS AND/OR EVALUATION REPORT.
2. OBSERVE VERIFY PRIOR TO PLACING CONCRETE THAT CAST IN PLACE
ANCHORS AND POST INSTALLED DRILLED ANCHORS HAVE
PROPER EMBEDMENT, SPACING AND EDGE DISTANCE.
CAST IN PLACE ANCHORS
AND POST INSTALLED
DRILLED ANCHORS
(DOWNWARD INCLINED)
3. CONTINUOUS
AND
DOCUMENT
- INSPECT AS REQUIRED PER APPROVED ICC-ES REPORT
- VERIFY THAT INSTALLER IS CERTIFIED FOR INSTALLATION OF
HORIZONTAL AND OVERHEAD INSTALLATION APPLICATIONS
- INSPECT PROOF LOADING AS REQUIRED BY THE CONTRACT
DOCUMENTS
POST-INSTALLED
ADHESIVE ANCHORS IN
HORIZONTAL OR
UPWARD INCLINED
ORIENTATIONS
4. OBSERVE VERIFY THAT ALL MIXES USED COMPLY WITH THE APPROVED
CONSTRUCTION DOCUMENTS
VERIFY USE OF
REQUIRED MIX DESIGN
5. CONTINUOUS AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE
SPECIMENS FOR STRENGTH TEST VERIFY THESE TESTS ARE
PERFORMED BY QUALIFIED TECHNICIANS.
PRIOR TO CONCRETE
PLACEMENT, FABRICATE
SPECIMENS FOR
STRENGTH TESTS,
PERFORM SLUMP AND
AIR CONTENT TESTS,
AND DETERMINE THE
TEMPERATURE OF THE
CONCRETE
6. CONTINUOUS VERIFY PROPER APPLICATION TECHNIQUES ARE USED
DURING CONCRETE CONVEYANCE AND DEPOSITING AVOIDS
SEGREGATION OR CONTAMINATION. VERIFY THAT
CONCRETE IS PROPERLY CONSOLIDATED.
INSPECT CONCRETE
PLACEMENT FOR
PROPER APPLICATION
TECHNIQUES
7. OBSERVE INSPECT CURING, COLD WEATHER PROTECTION, AND HOT
WEATHER PROTECTION PROCEDURES.
VERIFY MAINTENANCE
OF SPECIFIED CURING
TEMPERATURE AND
TECHNIQUE
8. OBSERVEVERIFY IN-SITU
CONCRETE STRENGTH,
PRIOR TO REMOVAL OF
SHORES AND FORMS
FROM BEAMS AND
STRUCTURAL SLABS.
9. OBSERVEINSPECT FORMWORK
FOR SHAPE, LOCATION
AND DIMENSIONS OF THE
CONCRETE MEMBER
BEING FORMED.
CONCRETE CONSTRUCTION SPECIAL INSPECTION
SOILS INSPECTION – VERIFY THE FOLLOWING ARE IN COMPLIANCE
IBC 1705.6
TASK INSPECTION
TYPE
DESCRIPTION
1. MATERIALS BELOW SHALLOW
FOUNDATIONS ARE ADEQUATE TO
ACHIEVE THE DESIGN BEARING
CAPACITY.
OBSERVE
2. EXCAVATIONS ARE EXTENDED TO
PROPER DEPTH AND HAVE
REACHED PROPER MATERIAL
OBSERVE
3. VERIFY USE OF PROPER MATERIALS,
DENSITIES AND LIFT THICKNESSES
DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL
CONTINUOUS
4. PRIOR TO PLACEMENT OF
COMPACTED FILL, INSPECT
SUBGRADE AND VERIFY THAT SITE
HAS BEEN PREPARED PROPERLY.
OBSERVE DURING FILL PLACEMENT, THE SPECIAL
INSPECTOR SHALL VERIFY THAT PROPER
MATERIALS AND PROCEDURES ARE USED IN
ACCORDANCE WITH THE PROVISIONS OF THE
APPROVED GEOTECHNICAL REPORT
SOILS SPECIAL INSPECTION
G
2 3 4 5 6 7 8 9 10
F
E
D
C
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-003
2BR
T Y
P
IC
A L S
T R
U C
T U
R A
L D
E T
A
IL
S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M d
4d or 2 1/2"
MIN.
d
HOOK
4d d
H O
O K d
D E
T A
IL
IN
G
D
IM
E N
S
IO
N
6d
D d
D E
T A
IL
IN
G
D
IM
E N
S
IO
N d
6d - FOR #3, #4 and #5 12d - FOR #6 THRU #8
REBAR BEND SCHEDULE
#3
REBAR
SIZE MIN. INSIDE
BEND DIAMETER
D [in]
180° HOOK 90° HOOK
BEAM
D
D
D = BEND DIAMETER
BEAM
D
NOTE:
D = FINISHED INSIDE BEND DIAMETER
d = BAR DIAMETER
D
DETAILING
DIMENSION
DETAILING
DIMENSION
D
STIRRUP, TIE
AND HOOP
#4
#5
#6
#7
#8
90° HOOK 135° HOOK
STIRRUP, TIE, AND HOOP GEOMETRY
STANDARD HOOK GEOMETRY
1.5
2.5
4.5
MIN. INSIDE
BEND DIAMETER
D [in]
STANDARD
HOOK
2.25
3.75
4.5
5.25 l dh
FACE OF CONC.
OR POUR JOINT
l dh
FACE OF CONC.
OR POUR JOINT
b b bb b b b b b b b b
MINIMUM SPLICE AND
DEVELOPMENT LENGTHS
CONCRETE STRENGTH = 4,000 PSI
LAP SPLICE DEVELOPMENT LENGTH
TOP
BARS
OTHER
BARS
STRAIGHT
TOP
BARS
OTHER
BARS
BAR
SIZE
#3 24 19 15 8
#4 32 25
#5 40 31
NOTES:
1. 'TOP BARS' ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE CAST BELOW THE BARS
2. 'OTHER BARS' ARE ALL VERTICAL BARS AND HORIZONTAL BARS WITH LESS THAN 12" OF FRESH CONCRETE CAST BELOW THE BARS.
3. WHEN SPLICING BARS OF DIFFERENT SIZES, USE THE SPLICE LENGTH OF THE LARGER BAR .
STANDARD
HOOK,
l dh
3" CLR.
MAIN OR
TEMPERATURE BAR
(TYP.)
STIRRUP OR TIE
EARTH/CONC.
CONCRETE CAST
AGAINST EARTH
NOTES:
1. PROTECTION COVER SHOWN IS MINIMUM PERMITTED.
2. THICKER PROTECTIVE COVER INDICATED IN SPECIFIC DETAILS SHALL GOVERN.
3. COMPLY WITH A CASE OF CONC. EXPOSED TO EARTH OR WEATHER FOR
STRL. SLAB-ON-GRADE.
4. PROTECTIVE COVER SHOWN IS FOR CAST-IN-PLACE CONCRETE ONLY.
C L R
2" CLR
MAIN OR
TEMPERATURE
BAR (TYP.)
FORMED CONC.
SURFACE
EXTERIOR
FACE
EARTH
STIRRUP OR TIE
CONCRETE EXPOSED TO
EARTH OR WEATHER
2" CLR
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
NOT TO SCALED1
TYPICAL REBAR HOOK DETAIL
NTSA1
TYPICAL REBAR SPLICE AND DEVELOPMENT LENGTH SCHEDULE
NTSA7
CONCRETE PROTECTION OF REINFORCING
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-004
2BR
T Y
P
IC
A L F
O U
N D
A T
IO
N
D E
T A
IL
S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
M
IN
BOTTOM OF
FOOTING
9"
M
IN
NOTE:
DO NOT TRENCH BELOW FOOTING
AFTER FOOTING IS POURED
FOR PIPES MORE THAN 3'-0" BELOW
BOTTOM OF FOOTING TRENCH MAY BE
BACKFILLED WITH COMPACTED
FILL/SPECIFICATIONS
WALL
SLEEVE
PIPE
SLEEVE
PIPE
3"
1' - 3"
NO EXCAVATION
ALLOWED BELOW THIS
BELOW
THIS CONCRETE
MUST BE PLACED
BEFORE FOOTING
10' - 0"
GROUND LINE
BACKFILL PER
SPECS.
BOTTOM OF TRENCH
EXCAVATION SHALL
NOT EXTEND BELOW
THIS LANE
TRENCH EXCAVATION
MIN.
1' - 6"
FOOTING
NOTE:
THE CONTRACTOR SHALL BE
RESPONSIBLE FOR SHORING, SHEATHING OR
OTHERWISE MAINTAINING THE SIDES OF THE
EXCAVATION FROM CAVE-INS UNTIL ALL
BACKFILL IS COMPLETED PER
SPECIFICATIONS.
M
IN
M A
X
THIS CONCRETE
MUST BE PLACED
BEFORE FOOTING
EXCAVATION PARALLEL TO FOOTING
C L R
T
Y P
M
IN
T
T
1' - 6"
LAP 24", TYP
C L R
ADD (3) #4X4'-0"
ADD BARS TO
MATCH
FOOTING REINF.
6" DIA MAX
PLAN
WALL FOOTING
PLAN
WALL FOOTING
LONGITUDINAL
REINFORCING
PER PLAN
WALL FOOTING
STANDARD HOOK
AT END OF FTG.
PLAN
WALL FOOTING
CONDITION AT CORNER CONDITION AT INTERSECTION CONDITION AT END
WALL FOOTING
CONCRETE WALL
PER PLAN
W
W /2
U .O
.N
PLAN
TYPICAL CONDITION AT END OF WALL
STANDARD HOOK IN LONGITUDINAL
WALL FOOTING REINFORCING
BARS AT FAR FACE OF
INTERSECTING FOOTING, TYP.
ELEVATION
EXTEND COL. FTG.
REINF. 40 BAR DIA.
(MIN.) INTO WALL FTG.
WALL FTG. REINF.
WALL FTG. BOT.
REINF. EXTENSION
COL. FTG.
REINF.
WALL FOOTING COLUMN FOOTING
COL. FTG.
REINF.
WALL FTG. REINF.
EXTEND WALL FTG.
REINF. 40 BAR DIA. (MIN.)
INTO COL. FTG.
SLAB ON GRADE
CONCRETE
WALL
SCARIFY 6", MOISTURE CONDITION
TO ABOVE THE OPTIMUM
MOISTURE, AND COMPACT TO
MINIMUM 90% OF MAX DRY
DENSITY.
E M
B E
D M
IN
SOFT AND/OR LOOSE SOILS SHALL BE OVER-
EXCAVATED TO FIRM/DENSE SOILS AND BACKFILLED
WITH ACCEPTABLE SELECT GRANULAR MATERIAL
COMPACTED IN ACCORDACE WITH THE
SPECIFICATIONS.
15 MIL. REINFORCED
POLYETHYLENE VAPOR
BARRIER, TYP.
4" CAPILLARY WATER
BARRIER, ASTM C33, NO. 67
6" SELECT GRANULAR MATERIAL.
M
A X
S E
E A
R C
H D
W G
FINISH GRADE
NOTE:
STRUCTURE IS DESIGNED FOR A FLAT SITE.
SITE SHALL BE GRADED TO MAINTAIN SLOPE
SETBACKS PER IBC 1808.7.
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1/2" = 1'-0"E1
TYPICAL PIPE THRU FOUNDATION AND TRENCH DETAILS
1" = 1'-0"A1
TYPICAL WALL FOOTING DETAIL
1 : 20C1
CONDITION AT COLUMN FOOTING
3/4" = 1'-0"A8
TYPICAL SOIL PREP
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-005
2BR
T Y
P
IC
A L S
L A
B O
N G
R A
D E
A N
D F
O O
T
IN
G D
E T
A
IL
S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
DEPRESSED SLAB AT EXTERIORSAWCUT JOINT (S.J.)CONSTRUCTION JOINT (C.J.)AT WALL
#4 CONT.
BARS
1/2" SQ. JT. SEALANT
OVER 1/2"t PRE-
MOLDED JT. FILLER
CONC. GRADE
SLAB AND REINF.
FACE OF WALL
1 1/2" DEEP CONT.
KEYWAY AT MID-
DEPTH
2- #4 CONT. EACH
SIDE OF CONSTRUCTION
JOINT
1 1/2" DEEP CONT.
KEYWAY AT MID-
DEPTH
CONC. GRADE
SLAB AND REINF.
2- #4 CONT.
CONC. GRADE
SLAB AND REINF.
FINISH GRADE
1/8" RADIUS
TOOLED EDGE
JOINT SEALANT
JOINT SEALANT2- #4 CONT. EACH
SIDE OF CONSTRUCTION
JOINT
1/8"
SAWCUT t/
8"
TYP.
4"
M
IN
TYP.
4"
JOINT SEALANT
t
NOTE: SEE A8/S-004 FOR SOIL PREP
SLAB ON GRADE
#4 @ 12"
(3) #5 CONT
WALL
REINFORCING
WALL
REINFORCING
DOWEL, MATCH VERT
REINF SIZE AND SPACING,
ALT HOOK
L A
P S
P L
IC
E
#4 @ 16"
2'-0"
2' - 0"
(2) #4 CONT
SLAB ON GRADE,
WHERE OCCURS
C L R
T Y
P
1' - 4"
L A
P S
P L
IC
E
C
L R
T Y
P
(2) #4 CONT
WALL
REINFORCING
WALL
REINFORCING
DOWEL, MATCH VERT
REINF SIZE AND SPACING,
ALT HOOK
6" CONC
WALL, SEE
S-006
SLAB ON GRADE
#4 @ 12" 12" 12"
CONC. GRADE
SLAB AND REINF.
#3 CONT
#3 @ 18" O.C.SEE ARCH,
4" MAX
S E
E A
R C
H
M A
X
CONC. GRADE
SLAB AND REINF.
#3 CONT @ EDGES, E.W.
AND @ 18" O.C. MAX E.W.
#3 @ 18" O.C. AROUND
PAD PERIMETER
S E
E A
R C
H
M A
X
#3 CONT @ EDGES, E.W.
AND @ 18" O.C. MAX E.W.
SEE ARCH
CURB, WIDTH ≤ 4" CURB, WIDTH > 12"
ROUGHEN
SURFACE IF CURB
IS NOT CAST
MONOITHIC WITH
SLAB POUR
ROUGHEN
SURFACE IF CURB
IS NOT CAST
MONOITHIC WITH
SLAB POUR
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
NOT TO SCALEA1
TYPICAL SLAB ON GRADE DETAILS
NTSD1
WF-1 SECTION
NTSD3
TS-1 SECTION
NOT TO SCALED6
TYPICAL SLAB ON GRADE CURB DETAILS
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-006
2BR
T Y
P
IC
A L C
O N
C R
E T
E W
A L L D
E T
A
IL
S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
CONCRETE WALL MINIMUM REINFORCING
WALL THICKNESS,
INCHES
BAR SIZE AND SPACING
HORIZ VERT
REMARKS
#4 @ 12"#4 @ 12"6"
#5 @ 12"#5 @ 12"8"
PRE-CAST CONCRETE SILL,
SEE ARCH DWGS
NOTE:
IF TYPICAL WALL VERT
REINF OCCURS AT A
HOLE, EXTEND VERT
BAR INTO HOLE IN-LIEU
OF ADDED #4 BAR
E M
B E
D
SILL BAR: 2-#5
MIN. CONT.
8" CONC WALL
2" DIA HOLES CAST IN PRE-CAST
WINDOW SILLS AT 4" FROM SILL
ENDS AND AT 4'-0" O.C. MAX.
MINIMUM 3 HOLES PER SILL.
FILL HOLES WITH NON-SHRINK,
NON-METALLIC GROUT
ADDED #4, MATCH SILL
HOLE SPACING
"T
D
MAX D=T
3D OR 4" MIN
SLEEVE, TYP.
SLAB
CONDUIT IN CENTER THIRD OF SLAB OR
WALL WHERE WALL REINF HAS 1 MAT IN
CENTER LOCATE CONDUIT IN SAME LAYER
WITH WALL VERT REINF OF VERT CONDUIT
D
3D OR 4" MIN
MAX D = T/3 OR 2"
WHICHEVER IS SMALLER
NOTE:
WHERE CLEAR DISTANCE BETWEEN SLEEVES IS IMPOSSIBLE OR MAX D IS
EXCEEDED, THIS AREA SHALL BE TREATED AS AN OPENING PER TYPICAL
DETAIL FOR OPENINGS ON WALL. CONTRACTOR SHALL LOCATE (E)
SLAB/WALL REINFORCING BY NON-DESTRUCTIVE MEANS TO AVOID
DAMAGE PRIOR TO DRILLING AND CORING FOR (N) PIPES AND CONDUITS
PROVIDE DOWELS TO MATCH
HORIZ REINF SIZE AND SPACING
M
IN
L A
P S
P L
IC
E
2'-0" MIN
LAP SPLICE
ALTERNATE
DIRECTION OF HOOK
2'-0" MIN
LAP SPLICE
(2) #5 OR MATCH WALL VERT,
WHICHEVER IS GREATER
2'-0" MIN
LAP SPLICE
#5 OR MATCH VERT REINF,
WHICHEVER IS GREATER
PROVIDE DOWELS TO
MATCH HORIZ REINF
SIZE AND SPACING
PLAN CORNER PLAN INTERSECTION PLAN END/JAMB
#3 TIES AND CROSS -
TIES @ 6" OC (WHEN
PIER WIDTH EXCEEDS
2'-0" USE NORMAL
HORIZ. REINFORCING)
#5 x 5'-0"
DIAGONAL EA
CORNER
SILL REINF.
PER
DETAILS
#5 x 5'-0"
DIAGONAL EA
CORNER
REINF. EA. SIDE
OF OPENING
(SEE NOTE 1)
HEADER
REINFORCING
SEE NOTE 2
VERTS
AT JAMBS (FULL
HEIGHT U.O.N.)
#4 EA. FACE OF PIER AT 8" O.C. - EXTEND
VERTS FULL HEIGHT WHEN PIER IS
ADJACENT TO DOOR OPENINGS
(OMIT AT PIERS 1'-0" OR LESS IN WIDTH)
MATCH FOOTING
OR WALL DOWELS
BELOW PER DETAILS
(SEE NOTE 3)
"A"
HEADER
REINFORCING
SEE NOTE 2
(SEE NOTE 4)
MECH'L WALL OPENING DOOR OPENING WINDOW OPENING
PIER SECTION
OPENOPENOPENOPEN
TOP OF SLAB
RECTANGULAR OPENINGS WITH L or H > 12"x12"
CIRCULAR WITH D>12"
#5 x (D+48") DIAGONAL
(4) SIDES
PIER WIDTH
L
(SEE NOTE 3)
2'-0" TYP.
T Y
P
H
H
D
WIDTH OF
OPENING
WIDTH OF
OPENING
"A"
"A"
"A"
NOTES:
1. VERTICAL AND HORIZONTAL BARS INTERRUPTED BY
OPENINGS SHALL BE REPLACED BY ADDITIONAL
REINFORCING EQUAL TO THAT INTERRUPTED. PLACE
HALF OF ADDITIONAL REINFORCING ON EACH SIDE OF
THE OPENING, (2) #5 MIN EACH SIDE (3" CC)
2. HEADER REINFORCING:
OPENING 5'-0" OR LESS - (2) #5 BARS, 4'-3" LONGER THAN OPENING
OPENING 5'-1" TO 7'-0" - (2) #6 BARS, 5'-0" LONGER THAN OPENING
OPENING 7'-1" TO 9'-0" - (2) #7 BARS, 5'-9" LONGER THAN OPENING
3. WHERE EXTENSION IS NOT POSSIBLE, EXTEND AS FAR
AS POSSIBLE AND HOOK, TYP.
4. DOWELS NOT REQUIRED TO FOOTING OR WALL BELOW
WHEN H1 < 8'-0"
(4) #5
SECTION "A"-"A"
SINGLE LAYER
LINTEL AND TOP OF WALL
TOP OF WALL
STD. HOOK
TYP WALL
REINF.
HEADER REINF
180° HOOK,
ALT HOOKS
3" 1 1/2"
3"
E Q
E Q
E Q
HORIZ
12" LONG KEY AT 24"
CLEAN SURFACE
PRIOR TO PLACING
CONCRETE
HORIZ WALL
REINF TYP
VERT WALL REINF
TYP UNLESS
OTHERWISE
NOTED
FIRST PLACEMENT
NOTES:
LOCATION AND DETAIL OF JOINT SHALL BE REVIEWED BY ARCHITECT
WHEN NOT LOCATED AT INTERSECTIONS OF WALLS PRIOR TO
CONSTRUCTING FORMS OR PLACING CONCRETE.
ROUGHENED SURFACE.
CLEARN PRIOR TO
PLACING 2ND POUR
CONTINUE
REINF ACROSS
JOINT
S
T P
O U
R N
D P
O U
R
HORIZONTAL
CONSTRUCTION JOINT
SECTION
NOTE:
JOINT LOCATION SHALL BE SUBMITTED TO
THE CONTRACTING OFFICER FOR REVIEW.
VERTICAL
CONSTRUCTION JOINT
PLAN
TYP WALL
REINF.
ALTERNATE SPLICES
4'-0" MIN. SPACING FOR
TYP. LAP (24" MIN.)
HORIZ. REINF.
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
1 1/2" = 1'-0"A8
WINDOW SILL DETAIL
NTSC8
TYPICAL CONDUIT IN OR THRU WALL
3/4" = 1'-0"F1
TYP CONCRETE WALL REINFORCING
NTSA1
TYPICAL CONCRETE WALL OPENING REINFORCING
NTSF7
CONCRETE WALL CONSTRUCTION JOINTS
NTSD6
TYPICAL WALL REINFORCING
E
E
C L R
E
X T
E R
IO
R
T Y
P
/4
C
L R
T Y
P
END SUPPORT INTERIOR SUPPORT
SLAB REINFORCING
TYPICAL TEMPERATURE REINFORCING SLAB ELEVATION
FACE OF WALL
DIRECTION
OF
SPAN
FACE OF WALL
MAIN SLAB
REINF.
BOTTOM CONT. BARS
FACE OF
SUPPORT
TOP BAR LAP AS REQUIRED.
ALTERNATE SPLICES.
TEMPERATURE REINF:
#4 @ 18" O.C., STAGGERED,TYP.
BOTTOM OUTERMOST BAR:
#4 @ 14" O.C.
TOP OUTERMOST BAR:
#4 @ 14" O.C.
FACE OF
SUPPORT
BOT. BAR LAP AS REQUIRED.
(LAP AT SUPPORT, TYP.)
BARS IN SAME
PLANE EVENLY
SPACED
TEMPERATURE REINF. (SPLICE BOT.
BARS AT SUPPORTS AND TOP BARS AT
MIDSPAN AS REDQ'D).
LAP 32 BAR DIA.
DIRECTION OF SPAN
END SUPPORT
/2
2" CLR
#4 DOWELS
@ 16" O.C.
BOND BEAM CONT
HORIZ REINF:
(2) #4 CONT
HORIZ WALL
REINF: (2) #4 CONT
2"
CONC BEAM TOP BARS
CONC BEAM BOT BARS
CONCRETE WALL
6"
CONC BEAM TOP BARS
CONC BEAM BOT BARS
M A
X
/2
MAX
5 1/2"
#4, EF
8" TYP
#4x4'-0", EF, CENTERED OVER OPENING
/2
ADDED STIRRUP
1 1/2" CLR, TYP
2' - 0"
2"
CONC WALL
PENETRATION FOR
ELECT CONDUITS.
SEE ELECT DWG.
EQ EQ
CONC BEAM TOP BARS
CONC BEAM BOT BARS
#4x6'-0", EF, CENTERED
OVER CONDUITS
/2
ADDED STIRRUP
3/4" CLR TYP
ELECT CONDUITS,
SEE ELECT DWG.
4' - 2" MIN FROM SUPPORT
1' - 1" MAX
30' - 9"
TYP
5' - 8"
TYP
5' - 8"
TYP
5' - 8"
T Y
P
TYP
1' - 11"
1'12
T Y
P
3 3
3 3
1'
1' OH
2 OH
3 OH -288
-288
-211
-160
-92
ZONE
P (-)
PSF
P (+)
PSF
-256
-261
-198
-158
-92
-183
-198
-166
-152
-92
100ft²≤A<500ft²20ft²≤A<100ft²A<20ft²
-109
-135
-135
-101
-62
-211 -169 -151 -109
HATCH
A≥500ft²
1 OH
-160
-150
-125
-101
P (-)
PSF
P (+)
PSF
P (-)
PSF
P (+)
PSF
P (-)
PSF
P (+)
PSF
-160 -158 -152 -101
WINDOWS: +/- 110 PSF
DOORS: +/- 105 PSF
ROOF C&C WIND PRESSURES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-007
2BR
T Y
P
IC
A L E
L E
V A
T E
D S
L A
B A
N D
B E
A M
D E
T A
IL
S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
J A
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
NOT TO SCALEA1
TYPICAL SUSPENDED SLAB DETAILS
1 1/2" = 1'-0"F1
CONCRETE BEAM DETAIL
NTSA8
COMPONENTS AND CLADDING WIND PRESSURES
E U
P D
A T
E D
D R
A W
IN
G
S F
O R
N E
W P
H A
S E
C O
N S
T R
U C
T
IO
N
J
A N
E1
S-301
A1
S-301
A6
S-301
WF-1
WF-1
WF-1
W F
-1
T S
-1
W F
-1
4" CONC. SLAB-ON-GRADE
WITH 6X6 W2.9XW2.9 AT MID-DEPTH
8" CONCRETE
WALL
6" CONCRETE WALL
S-201 D1
S-201 A6
S-201 A1
S-201 D6
S-201 F6
DEPRESSED SLAB,
SEE ARCH
C1
S-301
6" CONCRETE
WALL
CONC.
CURB
TS-1
T S
-1
TS-1
T S
-1
8" CONCRETE
WALL
(BELOW)
S.J.
S .J
S.J.
S.J.
EQ EQ EQ EQ
S .J
S .J
E1
S-301
A1
S-301
A6
S-301
OUTERMOST:
#4 @ 14" O.C. T&B
TEMPERATURE REINF.
#4 @ 18" O.C. T&B
6" THK CONCRETE
SLAB
C1
S-301
E9
S-311
CONC BEAM
1. TYPICAL FOOTING DETAILS, SEE S-004 AND S-005
2. TYPICAL CONCRETE SLAB ON GRADE DETAILS, SEE S-005.
3. TYPICAL CONCRETE WALL DETAILS, SEE S-006
4. TYPICAL CONCRETE SLAB DETAILS, SEE S-007
PROVIDE DOWELS TO MATCH
HORIZ REINF SIZE AND SPACING
ALTERNATE
DIRECTION OF HOOK
2'-0" MIN
LAP SPLICE
#5 OR MATCH VERT REINF,
WHICHEVER IS GREATER
PLAN INTERSECTION
" 3
6" WALL, #5 @ 12" HORIZONTAL8" WALL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-101
2BR
F L O
O R
A N
D R
O O
F P
L A
N
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
1/4" = 1'-0"A1
FOUNDATION PLAN
1/4" = 1'-0"A6
ROOF PLAN
02' 4' 8'1'3'4'
SCALE: 1/4"=1'-0"
3/4" = 1'-0"F1
TYP CONCRETE WALL REINFORCING 8" TO 6"
GROUND FLOOR
0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
CONCRETE
WALL
GROUND FLOOR
0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
CONCRETE
WALL
GROUND FLOOR
0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
CONCRETE
WALL
GROUND FLOOR
0"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
CONCRETE
WALL
S-311
A1
O.H.
GROUND FLOOR
0"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
CONCRETE BEAM
CONCRETE
WALL
S-007
F1
1. TYPICAL FOOTING DETAILS, SEE S-004 AND S-005
2. TYPICAL CONCRETE SLAB ON GRADE DETAILS, SEE S-005.
3. TYPICAL CONCRETE WALL DETAILS, SEE S-006
4. TYPICAL CONCRETE SLAB DETAILS, SEE S-007
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-201
2BR
W A
L L E
L E
V A
T
IO
N S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
1/4" = 1'-0"D1
WALL ELEVATION
1/4" = 1'-0"A6
WALL ELEVATION
1/4" = 1'-0"A1
WALL ELEVATION
1/4" = 1'-0"D6
WALL ELEVATION
1/4" = 1'-0"F6
WALL ELEVATION
02' 4' 8'1'3'4'
SCALE: 1/4"=1'-0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
S-311
A5
S-311
A9
WF-1 WF-1
S-311
A7
WF-1 TS-1
6" CONCRETE
PARTITION
GROUND FLOOR
0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
WF-1
6" CONC SLAB
S-311
A1
WF-1
WF-1
S-311
A3
S-311
E9
GROUND FLOOR
0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
WF-1 WF-1
TS-1
6" CONCRETE PARTITION
S-311
F1 S-311
E4
TS-1
GROUND FLOOR
0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
WF-1WF-1
6" CONCRETE PARTITION
1. TYPICAL FOOTING DETAILS, SEE S-004 AND S-005
2. TYPICAL CONCRETE SLAB ON GRADE DETAILS, SEE S-005.
3. TYPICAL CONCRETE WALL DETAILS, SEE S-006
4. TYPICAL CONCRETE SLAB DETAILS, SEE S-007
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-301
2BR
B U
IL
D
IN
G
S E
C T
IO
N
S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
1/4" = 1'-0"E1
BUILDING SECTION
1/4" = 1'-0"A1
BUILDING SECTION
1/4" = 1'-0"A6
BUILDING SECTION
1/4" = 1'-0"C1
BUILDING SECTION
02' 4' 8'1'3'4'
SCALE: 1/4"=1'-0"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
8"
(2) #9
#3 STIRRUP. 2" FROM
FACE OF SUPPORT,
REMAINDER @ 6" O.C.
(2) #5
M
IN
1. TYPICAL FOOTING DETAILS, SEE S-004 AND S-005
2. TYPICAL CONCRETE SLAB ON GRADE DETAILS, SEE S-005.
3. TYPICAL CONCRETE WALL DETAILS, SEE S-006
4. TYPICAL CONCRETE SLAB DETAILS, SEE S-007
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-311
2BR
W A
L L S
E C
T
IO
N S
F E
M A
P E
R M
A N
E N
T H
O U
S
IN
G
C
IP
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
I -5
R E
G
IO
N A
L E
N G
IN
E
E R
IN
G
C E
N T
E R
H O
N O
L U
L U
D
IS
T R
IC
T
H O
N O
L U
L U
H
I
R N
R N
C Y
A
U G
CIP DESIGN COMPLETE
S A
IP
A
N
B
E D
R O
O M
1 1/2" = 1'-0"E9
BEAM SECTION
06"
SCALE: 1 1/2"=1'-0"
3" 1' 1½'
0 1' 2'½'1'
SCALE: 1"=1'-0"
GROUND FLOOR
0"
TOP OF CONC
BEAM @ HIGH
SIDE OF ROOF
9' - 10"
TOP OF CONC
BEAM @ LOW SIDE
OF ROOF
8' - 8"
WF-1
8" CONCRETE WALL
4" S.O.G. CONCRETE STOOP.
SEE ARCH DWG.
#5 CONT (2) #3 CONT
6" CONCRETE SLAB
AND REINFORCEMENT
V A
R
IE
S
M
IN
S-006
A8
#4 @ 16" O.C.
WF-1
8" CONCRETE WALL
4" S.O.G.
CONCRETE WALL
(3) #3 CONT
#5 CONT
6" CONCRETE SLAB
AND REINFORCEMENT
WF-1
8" CONCRETE
WALL
4" S.O.G.
WF-1
8" CONCRETE WALL
4" S.O.G.
#5 CONT
6" CONCRETE SLAB
AND REINFORCEMENT
GROUND FLOOR
0"
WF-1
8" CONCRETE
WALL
4" S.O.G.
4" S.O.G.
#4 @ 16"
ADDED #4
#3x3'-6", EACH SIDE
#3 CONT, PER PLAN
#5 CONT, PER PLAN GUTTER D.S.
PLAN
1" = 1'-0"A9
WALL SECTION
1" = 1'-0"A5
WALL SECTION
1" = 1'-0"A1
SECTION AT WATER TANK
1" = 1'-0"A7
WALL SECTION
1" = 1'-0"A3
WALL SECTION
3/4" = 1'-0"D3
GUTTER D.S.
L A
P S
P L
IC
E
CONCRETE ROOF
SLAB, SEE PLAN
DOWEL, MATCH WALL VERT
CONCRETE ROOF
SLAB, SEE PLAN
(2) #3 CONT
STD HOOKS, ROTATE
AS NECESSARY, TYP
WALL
REINFORCING
WALL
REINFORCING
6" CONC WALL,
SEE S-006
ROOF SLAB
G A
P , 1
M
A X
L4X4X3/8, L=6", WITH
(2) 1/2" DIA EXPANSION
ANCHORS, 3" EMBED MIN.
E6
S-311
L4X4X3/8, L=6" @ 4'-0", WITH
(2) 1/2" DIA EXPANSION
ANCHORS, 3" EMBED MIN.
1"4"1"
STAGGER ANGLES
2' - 0" 2' - 0"
NOTE: OPTION TO PROVIDE
3/8" THK BENT PLATE WITH
4" LONG LEGS INLIEU OF
L4X4X3/8.
1" = 1'-0"F1
EDGE OF ROOF DETAIL
1 1/2" = 1'-0"E4
6" PARTITION WALL TOP
1 1/2" = 1'-0"E6
6" PARTITION WALL TOP
06"
SCALE: 1 1/2"=1'-0"
3"
0½'1'
SCALE: 1"=1'-0"
PART 1 GENERAL
1.1 GENERAL REQUIREMENTS
PERFORM SPECIAL INSPECTIONS IN ACCORDANCE WITH THE STATEMENT OF SPECIAL INSPECTIONS, SCHEDULE OF SPECIAL INSPECTIONS AND CHAPTER 17 OF ICC IBC. THE STATEMENT OF SPECIAL INSPECTIONS AND SCHEDULE OF SPECIAL INSPECTIONS ARE INCLUDED AS AN ATTACHMENT TO THIS SPECIFICATION. SPECIAL INSPECTIONS ARE TO BE PERFORMED BY AN INDEPENDENT THIRD PARTY AND ARE INTENDED TO ENSURE THAT THE WORK OF THE PRIME CONTRACTOR IS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND APPLICABLE BUILDING CODES. SPECIAL INSPECTIONS DO
NOT TAKE THE PLACE OF THE THREE PHASES OF CONTROL INSPECTIONS PERFORMED BY THE
CONTRACTOR'S QC MANAGER OR ANY TESTING AND INSPECTIONS REQUIRED BY OTHER SECTIONS OF
THE SPECIFICATIONS
1.2 DEFINITIONS
1.2.1 CONTINUOUS SPECIAL INSPECTIONS
CONTINUOUS SPECIAL INSPECTIONS IS THE CONSTANT MONITORING OF SPECIFIC TASKS BY A
SPECIAL INSPECTOR. THESE INSPECTIONS MUST BE CARRIED OUT CONTINUOUSLY OVER THE
DURATION OF THE PARTICULAR TASKS.
1.2.2 PERIODIC SPECIAL INSPECTIONS
PERIODIC SPECIAL INSPECTIONS IS SPECIAL INSPECTIONS BY THE SPECIAL INSPECTOR WHO IS
INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING
PERFORMED.
1.2.3 PERFORM
PERFORM THESE TASKS FOR EACH WELD, FASTENER OR BOLTED CONNECTION, AND NOTED
VERIFICATION.
1.2.4 OBSERVE
OBSERVE THESE ITEMS RANDOMLY DURING THE COURSE OF EACH WORK DAY TO INSURE THAT
APPLICABLE REQUIREMENTS ARE BEING MET. OPERATIONS NEED NOT BE DELAYED PENDING THESE
INSPECTIONS AT CONTRACTOR’S RISK.
1.2.5 SPECIAL INSPECTOR (SI)
A QUALIFIED PERSON RETAINED BY THE CONTRACTOR AND APPROVED BY THE CONTRACTING
OFFICER AS HAVING THE COMPETENCE NECESSARY TO INSPECT A PARTICULAR TYPE OF
CONSTRUCTION REQUIRING SPECIAL INSPECTIONS. THE SI MUST BE AN INDEPENDENT THIRD
PARTY HIRED DIRECTLY BY THE PRIME CONTRACTOR.
1.2.6 ASSOCIATE SPECIAL INSPECTOR (ASI)
A QUALIFIED PERSON WHO ASSISTS THE SI IN PERFORMING SPECIAL INSPECTIONS BUT MUST
PERFORM INSPECTION UNDER THE DIRECT SUPERVISION OF THE SI AND CANNOT PERFORM
INSPECTIONS WITHOUT THE SI ON SITE.
1.2.7 THIRD PARTY
A THIRD PARTY INSPECTOR MUST NOT BE COMPANY EMPLOYEE OF THE CONTRACTOR OR ANY SUB-
CONTRACTOR PERFORMING THE WORK TO BE INSPECTED.
1.2.8 CONTRACTING OFFICER
THE GOVERNMENT OFFICIAL HAVING OVERALL AUTHORITY FOR ADMINISTRATIVE CONTRACTING
ACTIONS. CERTAIN CONTRACTING ACTIONS MAY BE DELEGATED TO THE CONTRACTING OFFICER'S
REPRESENTATIVE (COR).
1.2.9 CONTRACTOR'S QUALITY CONTROL (QC) MANAGER
AN INDIVIDUAL RETAINED BY THE PRIME CONTRACTOR HAVING THE…
This is the start of the file's text. The full file is on GovTribe.