A.2.11.3 468335_Rev 1 Dwgs (03-25-21).pdf
PDF 4 MB Posted
- Solicitation number
- W9128A-21-B-0005
About this file
This solicitation is for the replacement of the HVAC system at the U.S. Army Museum located at Fort Derussy in Hawaii. The project magnitude is estimated between $5-10 million. The solicitation is set aside as a competitive procurement for Women Owned Small Businesses only. An organized pre-bid site visit will be held for interested parties to register and attend, with the date and time to be determined via a future amendment. The selected contractor will demolish the existing HVAC system in its entirety and replace it with a new system. The Army Corps of Engineers Engineering District Honolulu is the issuing agency. The response deadline and award date are not specified.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H O
N O
L U
L U D
IS
T R
IC
T
F O
R T S
H A
F T
E R
H A
W A
II
. W
A -1
-D -0
.F
IR
S T T
IT
L E
S E
C O
N D T
IT
L E
K
A L
IA
R
D
H O
N O
L U
L U
O A
H U
H I
US Army Corps of Engineers ®
SHEET ID
U S A
R M
Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I
D
IS
S
U E D
A T
E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F O
R T D
E R
U S
S Y
O A
H U
H A
W A
II
R E
P L
A C
E H
V A
C S
Y S
T E
M
B A
T T
E R
Y R
A N
D O
L P
H
468335
O
C T
LICENSE EXPIRATION 04/30/2022
UNDER MY SUPERVISION
THIS WORK WAS PREPARED BY ME OR
SIGNATURE
PROFESSIONAL
NO. 12107-S
ENGINEER
LICENSED
H
AWAI,I
S.U .A
G E
O R G
E O.
GUTIERREZ
J R
RTA , DBB, 15 OCT 2020
GC001
G
G U
T
IE
R R
E Z J
R
G
G U
T
IE
R R
E Z J
R
K S
H
IM
O K
A W
A
K
U M
E M
O T
O
CONSTRUCTION PHASING NOTES
C O
N S
T R
U C
T
IO
N P
H A
S
IN
G N
O T
E S
N A
G A
M
IN
E O
K A
W A E
N G
IN
E E
R S I
N C
B
IS
H O
P S
T S
T E
H O
N O
L U
L U
H I
HAS BEEN LOCATED INTO AREAS OF THE CURRENT PHASE, AT NO EXTRA COST TO THE GOVERNMENT.
THE CONTRACTOR SHALL ACCOMMODATE MUSEUM STAFF WHEN STAFF IS CURRENTLY LOCATED OR 5.
OCCUPIED WHERE WORK WILL BE DONE BASED ON THE CURRENT PHASE.
THE CONTRACTOR SHALL COORDINATE WITH THE COR A WEEK IN ADVANCE OF ANY AREAS TO BE 4.
CURRENT PHASE IT IS IN UNTIL THAT PHASE HAS REACHED SUBSTANTIAL COMPLETION.
THE CONTRACTOR SHALL BE RESTRICTED TO WORK IN SPECIFIED AREAS AS IT PERTAINS TO THE 3.
THE ARMY MUSEUM.
ALL AREAS DURING THE PROJECT, SUBJECT TO REVIEW AND APPROVAL BY THE GOVERNMENT AND
FOR THE PHASES NOTED ABOVE, THE CONTRACTOR WILL BE ALLOWED TO SCOPE PLANNED WORK IN 2.
REFER TO MECHANICAL DRAWINGS SHEETS FOR MORE INFORMATION.1.
NOTES:
INSTALLED AIR CONDITIONING SYSTEM.
INSTALL NEW SECOND FLOOR EWA SIDE AIR CONDITIONING SYSTEM. TEST, BALANCE AND ADJUST NEWLY
PHASE 6
DEMOLISH SECOND FLOOR EWA SIDE AIR CONDITIONING SYSTEM.
PHASE 5
ADJUST NEWLY INSTALLED AIR CONDITIONING SYSTEM.
INSTALL NEW SECOND FLOOR DIAMOND HEAD SIDE AIR CONDITIONING SYSTEM. TEST, BALANCE AND
PHASE 4
DEMOLISH SECOND FLOOR DIAMOND HEAD SIDE AIR CONDITIONING SYSTEM.
PHASE 3
CONDITIONING SYSTEM).
TRANSFORMER PRIOR TO OPERATION OF NEW CHILLER AND NEW DOAS (DEDICATED OUTDOOR AIR
BALANCE AND ADJUST GROUND FLOOR AIR CONDITIONING SYSTEM. INSTALL AND ENERGIZE NEW
INSTALL GROUND FLOOR NEW MECHANICAL SYSTEMS. CAP STUB-OUTS TO THE SECOND FLOOR. TEST, PHASE 2
POSSIBLE.
THE NEW INSTALLATION. THE EXISTING PACKAGE UNIT SHALL REMAIN IN OPERATION AS LONG AS
THE LOBBY AND GIFT SHOP SHALL REMAIN OPEN DURING THE FIRST FLOOR DEMOLITION AND START OF
PHASE 1A
POSSIBLE PRIOR TO ON SITE CONSTRUCTION.
NOT START PRIOR TO RECEIVING NEW EQUIPMENT. ENTIRE MUSEUM WILL STAY OPEN AS LONG AS
DEMOLISH EXISTING FIRST FLOOR CHILLED WATER MECHANICAL SYSTEMS. ON SITE DEMOLITION SHALL
PHASE 1
/2
/2
A D
D E
D N
O T
E S
N O
L U
L U D
IS
T R
IC
T
F O
R T S
H A
F T
E R
H A
W A
II
. W
A -1
-D -0
.F
IR
S T T
IT
L E
S E
C O
N D T
IT
L E
K
A L
IA
R
D
H O
N O
L U
L U
O A
H U
H I
US Army Corps of Engineers ®
SHEET ID
U S A
R M
Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I
D
IS
S
U E D
A T
E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F O
R T D
E R
U S
S Y
O A
H U
H A
W A
II
R E
P L
A C
E H
V A
C S
Y S
T E
M
B A
T T
E R
Y R
A N
D O
L P
H
468335
O
C T
RTA , DBB, 15 OCT 2020
FORT DERUSSY BEACH
ENCLOSURE
EXISTING MECH
DO NOT DAMAGE
EXISTING TREE, TYP
EXISTING LANDSCAPING AREA
U.S. ARMY MUSEUM OF HAWAII (EXISTING)
WALKWAY
EXISTING CONC
TO KALIA ROAD
DRIVEWAY
EXISTING
WALKWAY
EXISTING CONC
GRASSED AREA
EXISTING
ENCLOSURE
NEW TRANSFORMER
ELEC DWGS
MUSEUM BUILDING, SEE
TRANSFORMER FOR
EXISTING PAD MOUNTED
DO NOT DAMAGE
EXISTING LIGHT POLE,
REPRESENTATIVE
POH COR AND GARRISON DPW
SHALL BE REVIEWED AND APPROVED BY THE
APPROVAL. ITS EXACT SIZE AND LOCATION
PROPOSED COSA SHALL BE SUBMITTED FOR
MOBILIZATION, THE CONTRACTOR'S
AND STORAGE AREA (COSA). PRIOR TO
SUGGESTED CONTRACTOR'S OPERATIONS
PROTECTION REQUIREMENTS
ENVIRONMENTAL
COMPLY WITH APPLICABLE
PATTERN, AND SHALL
EXISTING DI AND DRAINAGE
COSA SHALL ACCOMMODATE
EXISTING DROP INLET (DI),
GI002
G
G U
T
IE
R R
E Z J
R
G
G U
T
IE
R R
E Z J
R
K S
H
IM
O K
A W
A
K
U M
E M
O T
O
S
IT
E P
L A
N
B3
NNOT TO SCALE
SITE PLAN
N A
G A
M
IN
E O
K A
W A E
N G
IN
E E
R S I
N C
B
IS
H O
P S
T S
T E
H O
N O
L U
L U
H I
/1
/2
A
D D
E D E
X
IS
T
IN
G D
R O
P I
N L E
T N
O T
S
N O
L U
L U D
IS
T R
IC
T
F O
R T S
H A
F T
E R
H A
W A
II
. W
A -1
-D -0
.F
IR
S T T
IT
L E
S E
C O
N D T
IT
L E
K
A L
IA
R
D
H O
N O
L U
L U
O A
H U
H I
US Army Corps of Engineers ®
SHEET ID
U S A
R M
Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I
D
IS
S
U E D
A T
E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F O
R T D
E R
U S
S Y
O A
H U
H A
W A
II
R E
P L
A C
E H
V A
C S
Y S
T E
M
B A
T T
E R
Y R
A N
D O
L P
H
468335
O
C T
LICENSE EXPIRATION 04/30/2022
UNDER MY SUPERVISION
THIS WORK WAS PREPARED BY ME OR
SIGNATURE
PROFESSIONAL
NO. 12107-S
ENGINEER
LICENSED
H
AWAI,I
S.U .A
G E
O R G
E O.
GUTIERREZ
J R
RTA , DBB, 15 OCT 2020
(E) STUD WALL
COAST ARTILLERY
STORM
GATHERING
GALLERY
RANDOLPH
BATTERY
ONLY)
(STAFF
ROOM
COLLECTION
B7
S-504
F1
S-503
F4
C4
S-502
D9
S-505
A1
SIMSEE
IN (E) CONC HDR ABOVE,
PENETRATION (16" W x 14" H)
(N) MECH DUCT
DWGS
DUCT, SEE MECH
FOR (N) MECH
(E) HOLE ABOVE
TUNNEL
(E)
WALL
(E) CONC
8" THK)
INFILL (EST
(E) CONC
CONC WALL
FACE OF (E)
COL, TYP
(E) CONC
WALL
(E) 12" CONC
PILASTER COLS, TYP
(E) 9"x18" CONC
(E) 8" THK CMU WALL
(ASSUME 8" THK)
(E) CMU INFILL (E) TUNNEL
(E) TUNNEL
(E) SOG
CONC COL, TYP
(E) 15"x20"
WALL
(E) 8" CONC
CMU WALL
(E) 8" THK
(E) STUD WALL
WALL
(E) CONC
SEE MECH DWGS
FOR (N) MECH DUCT,
(E) HOLE ABOVE
(E) CONC WALL, SEE
PENETRATIONS ABOVE IN
(N) MECH PIPE
CONC WALL, SEE
ABOVE (16" W x 16" H) IN (E)
(N) MECH DUCT PENETRATION
CONC WALL, SEE
ABOVE (16" W x 10" H) IN (E)
(N) MECH DUCT PENETRATION
SEE
PENETRATION ABOVE,
(N) ELEC CONDUIT
SEE
IN (E) CONC HEADER,
PENETRATION ABOVE
(N) ELEC CONDUIT
SIMWITH CONC, SEE
PORTION OF (E) PENETRATION
DWGS. INFILL UNUSED
(N) MECH DUCT, SEE MECH
(E) PENETRATION ABOVE FOR
CONC WALL, SEE
PENETRATIONS ABOVE IN (E)
(N) MECH PIPE
GUN DECK
TO 2ND FLR
(E) STAIR UP
CONC WALL
(E) 36" THK
RETAINING WALL
(E) CONC
TUNNEL
(E) ACCESS
42" H) ABOVE, SEE
W x 18" H AND 42" W x
PENETRATIONS (14"
TWO (N) MECH DUCT
DAMAGE, TYP
(E) CONC COL, DO NOT
CEILING, SEE
CONC FLR AND
CONNECTION TO (E)
DWGS, FOR
WALL PER ARCH
MTL STUD PARTITION
(N) NON-LOAD BRG
DWGS AND DETAIL
= 2000 LBS MAX), SEE MECH
FOR (N) AHU (OPERATIVE WT
(N) W8x STL BM SUPPORT
COL, DO NOT DAMAGE
(E) CONC WALL AND
MECH DWGS
DUCT, SEE
FOR (N) MECH
(E) HOLE ABOVE
HAWAII ON DEFENSE
EARLY AVIATION
AIR DEFENSES
GIFT SHOP
STORAGE
HAMS OFFICE
EARLY HAWAIIAN WARFARE
ENTRANCE
LOBBY
JAN/ STORAGE
THE GREAT WAR
MOBILE FORCESSHELL ROOM
SPANISH - AMERICAN WARSUGAR AND SOLDIERS
ROOM
MEN'S
ROOM
WOMEN'S
ROOM
HAWAIIAN
(E) TUNNEL
ROOM
MECHANICAL
ROOM
CONFERENCE
SMALL
S-101
NSCALE: 1/8" = 1'-0"
S E
E A
/S -1
M A
T C
H L
IN
E
GRAPHICS SCALE
4'
1/8" = 1'-0"
1'0 2' 6'8' 16' 24'
FOUNDATION AND FIRST FLOOR PLAN A
KEYPLAN
F O
U N
D A
T
IO
N A
N D F
IR
S T F
L O
O R P
L A
N A
G
G U
T
IE
R R
E Z J
R
G
G U
T
IE
R R
E Z J
R
K S
H
IM
O K
A W
A
K
U M
E M
O T
O
N A
G A
M
IN
E O
K A
W A E
N G
IN
E E
R S I
N C
B
IS
H O
P S
T S
T E
H O
N O
L U
L U
H I
CONSTRUCTION. IMMEDIATELY NOTIFY CONTRACTING OFFICER OF ANY CONFLICTS.
CMU WALLS WITH MECHANICAL AND ELECTRICAL CONTRACTORS PRIOR TO
CONTRACTOR SHALL VERIFY SIZE OF NEW OPENINGS IN EXISTING CONCRETE AND 4.
PIPES AND CONDUITS.
SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS OF ALL EQUIPMENT, 3.
DEPRESSIONS, PARTITION WALLS, OPENINGS, CURBS, ETC.
SEE ARCHITECTURAL DRAWINGS FOR ALL ELEVATIONS, DIMENSIONS, SLOPES, 2.
S-506 FOR TYPICAL DETAILS.
SEE SHEETS S-001 AND S-002 FOR GENERAL NOTES AND SHEETS S-501 THROUGH 1.
NOTES:
/1
/2
A
D D
E D N
O T
T Y
P
IC
A L D
E T
A
IL
S
D4
MECHANICAL UNIT SUPPORT DETAIL
D1
MECHANICAL UNIT SWAY BRACING DETAIL
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
B3 NOT TO SCALE
A1 NOT TO SCALE
DETAIL
A3 NOT TO SCALE
SHALLOW BEAM TO BEAM
G
G U
T
IE
R R
E Z J
R
G
G U
T
IE
R R
E Z J
R
K S
H
IM
O K
A W
A
K
U M
E M
O T
O
NOT TO SCALE NOT TO SCALE
TO 24" WIDE
PLAN - OPENINGS UP
N A
G A
M
IN
E O
K A
W A E
N G
IN
E E
R S I
N C
B
IS
H O
P S
T S
T E
H O
N O
L U
L U
H I
B1
NOT TO SCALE
MAX TYPICAL
DECK OPENING UP TO 11"
PLAN - SMALL REINFORCING
B7
MECHANICAL UNIT SUPPORT DETAIL
SCALE AS NOTED
F7
PLAN
SCALE: 1/2" = 1'-0" F9
BASE PLATE PLAN
SCALE: 3" = 1'-0"
C7 C9 SCALE: 3" = 1'-0"
SECTION
SCALE: 3" = 1'-0"
SECTION
GRAPHICS SCALE
2"
3" = 1'-0"
0 1" 1'4" 8"
1'
1/2" = 1'-0"
6"0 2' 6'4'
/2
/2
R
E V
IS
E D D
E T
A
IL
B
DIRECTION), SEE
BENT PL (2 EA PER
PROVIDE SWAY BRACING
SECURE TO L3x3
3/8" DIA ROD, TYP.
COUPLER NUT OR TURNBUCKLE
RUBBER ISOLATOR, PER MECH
ISOLATOR, PER MECH
GALV STEEL SPRING
MANUF REQ'MTS, SEE NOTE
LOCATE SUPPORTS PER
RUBBER GROMMET, PER MECH
≤ 250 LBS
TOTAL WT
MECH UNIT
MECH
METAL SCREWS, PER
NEOPRENE PADS AND
SECURE UNIT W/
INFO NOT SHOWN
SEE FOR
AFTER INSTALLATION, TYP
WRECK BOLT THREADS
BENT PL 1/2x2
CONDITION AT EXISTING STEEL BEAM
BENT PL 1/2x2
OF (E) STL BM
BOT FLANGE
45 DEG
D4
S-504
D1
Q
L6x6x5/16x0'-3"
ROD
(1) 5/8" DIA HS BOLT
BOLT
(1) 5/8" DIA HS
PER PLAN
(E) STL BM
BOLTS AT 3"
(2) 5/8" DIA HS
BOLTS AT 3"
(2) 5/8" DIA HS
PLAN FOR LOCATION
SEE ROOF FRAMING
L3x3x1/4 SUPPORT BM, ORIENTATION
DWGS FOR SIZE AND PLAN
OR CHANNEL SEE MECH
GALV STEEL ANGLE IRON
FIELD VERIFY DIMENSION, TYP
ROOF DECK
BOT OF (E) MTL
SERVICE SPACES
MAINTENANCE /
ACCESS DOOR AND
INTERFERE W/ UNIT
PORTS MUST NOT
UNIT SUP
NOTE
FLOOR PER MECH DWGS
CLEARANCE TO FINISH
MIN VERTICAL
H O
N O
L U
L U D
IS
T R
IC
T
F O
R T S
H A
F T
E R
H A
W A
II
. W
A -1
-D -0
.F
IR
S T T
IT
L E
S E
C O
N D T
IT
L E
K
A L
IA
R
D
H O
N O
L U
L U
O A
H U
H I
US Army Corps of Engineers ®
SHEET ID
U S A
R M
Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I
D
IS
S
U E D
A T
E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F O
R T D
E R
U S
S Y
O A
H U
H A
W A
II
R E
P L
A C
E H
V A
C S
Y S
T E
M
B A
T T
E R
Y R
A N
D O
L P
H
468335
O
C T
LICENSE EXPIRATION 04/30/2022
UNDER MY SUPERVISION
THIS WORK WAS PREPARED BY ME OR
SIGNATURE
PROFESSIONAL
NO. 12107-S
ENGINEER
LICENSED
H
AWAI,I
S.U .A
G E
O R G
E O.
GUTIERREZ
J R
RTA , DBB, 15 OCT 2020
C6x8.2 UON
ADD (N)
A3
L3x3x1/4
ADD (N)
A1
S-504
SIM
UNDERSIDE OF (E) DECK
STRENGTHENING PL TO
ADD (N) 12 GA
PARALLEL TO FLUTE
AND 6" OC MAX AT PL
SCREWS AT EA DECK RIDGE
3/16" DIA x 2" LONG CONC
(E) CONC TOPPING
(E) METAL DECK W/
(N) OPEN'G
(E) CONC TOPPING
(E) METAL DECK W/
(2'-0" MAX WIDTH)
DIMENSION PER PLAN
TYP, EA END
(E) Wx BM PER PLAN
(N) OPEN'G
3/4 "
OR 11" DIA
UP TO 11" SQ
3/4 "
MIN
6"
MIN
6"
P E
R P
L A
N
D
IM
E N
S
IO
N
W x
H D
G
W x
H D
G
L3x3x1/4 (HDG)
L3x3x1/4 (HDG)
STD (HDG), TYP
BELOW 3" PIPE
STUB POST
UNIT ABOVE
LINE OF MECH
C7
S-504
TYP
C9
S-504
TYP
(VERIFY)
4'-0"
(V E
R
IF
Y
MANUF, TYP
HOLES PER EQPT
MOUNTING BOLT
W6x
TYP
EXP BOLTS,
1/4
1/4
VERTICAL
PLAN, PLUMB
STUB POST PER
PER MECH DWGS
(LEVEL) ELEVATION
TOP OF STEEL
W6x
MANUF, TYP
HOLES PER EQPT
MOUNTING BOLT
(F
IE
L D V
E R
IF
Y
V A
R
IE
S
(F
IE
L D V
E R
IF
Y
V A
R
IE
S
CL STUB POST
STIFF PL
3/8"
Lx
CL STUB POST
Lx
PL 3/8" x 4"
BOLTS AT 3"
(2) 5/8" DIA HS
/4
3"
(E) SLOPE)
(FIELD VERIFY
ON GRADE
CONC SLAB
TOP OF (E)
REQUIRED, TYP
OF POST AS
BEVEL EDGE
T Y
P
(1
M A
X
F
IE
L D V
E R
IF
Y
PL (HDG)
1/2" THK STL
PER PLAN
STUB POST
(GALV)
BOLT, TYP
1/2" DIA EXP
TYP
1 1/2 "
EXISTING
2"
(N) C6x PER PLAN
PL 3/8"x4 1/2"x7"
1/4
3"
(E) Wx BM
1/2"
OPENING
NEW
TOPPING
(E) CONC
(E) MTL DECK
PER PLAN
(N) Lx
EA DECK VALLEY
CONC SCREWS AT
3/16" DIA x 2" LG
ON (E) MTL DECK
(E) CONC TOPPING
SCREWS
CL
2"
CONTROL BOLTS
TENSION
HIGH-STRENGTH
(2) 5/8" DIA
STEEL NOTE 13, TYPICAL
SHEET S-002, STRUCTURAL
INSTALLED SLOWLY. SEE
FIELD WELDS SHALL BE
NOTE:
MOBILE
FORCES
SHELL
ROOM
COAST ARTILLERY
AIR
DEFENSES
REMOVE
EXST
RE
EX
REMOVE
EXST 24x24
(TYP OF 2)
REMOVE
EXST 24x12
(TYP OF 2)
REMOVE
EXST
48/14
REMOVE
EXST
28/14
REMOVE
EXST
18/14
FCU
EARLY AVIATIONTHE GREAT WAR
FCU
FCU
SPANISH-AMERICAN WAR
JAN/
STORAGE
FCU
SUGAR AND SOLDIERS
FCU
EARLY HAWAIIAN WARFARE
HAWAIIAN
ROOM
GIFT SHOP
BATTERY
RANDOLPH
GALLERY
SMALL
CONF
ROOM
HAMS
OFFICE
STORAGE
ENTRANCE
LOBBY
REMOVE
EXST
28/14
WOMEN'S
RESTROOM
MEN'S
RESTROOM
FCUFCU
FCU
REMOVE
EXST
18/14
REMOVE
EXST
REMOVE
EXST
REMOVE
EXST
REMOVE
EXST
REMOVE
EXST
REMOVE
EXST
REMOVE
EXST
REMOVE
EXST
REMOVE
EXST
28/14
REMOVE
EXST 24x12
(TYP OF 3)
REMOVE
EXST 24/14
REMOVE
EXST 24x12
(TYP OF 3)
REMOVE
EXST 24/14
REMOVE
EXST CHW
PIPING
REMOVE
EXST CHW
PIPING
REMOVE
EXST CHW
PIPING
REMOVE
EXST CD
PAC
REMOVE
EXST DUCTWORK
AND AIR DEVICES
POC
EXST OUTSIDE
AIR HOOD TO
REMAIN
COLLECTION
ROOM
(STAFF ONLY)
REMOVE
HAUL &
DISPOSE
EXST
REMOVE
EXST
CONCRETE
PAD
PLAN
NORTH
DEMOLITION MECHANICAL PLAN
SCALE: 1/8"=1'-0"
PARTIAL FIRST FLOOR
NOTE:
DEMOLISH EXISTING A/C SYSTEM IN IT'S ENTIRETY.
M-101
D E
M O
L
IT
IO
N
M E
C H
A N
IC
A
L P
L A
N
P A
R T
IA
L F
IR
S
T F
L O
O R
W
A
-1
-D -0
A N
S I D
C S
N
T E
C
D H
N
H O
N O
L U
L U
D
IS
T R
IC
T
F O
R T
S H
A F
T E
R H
A W
A
II
. W
A
-1
-D -0
.F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
K A
L
IA
R D
H O
N O
L U
L U
O
A H
U H
I
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F O
R T
D E
R U
S S
Y
O A
H U
H
A W
A
II
R E
P L
A C
E H
V A
C S
Y S
T E
M
B A
T T
E R
Y R
A N
D O
L P
H
468335
O C
T
RTA , DBB, 15 OCT 2020
LICENSE EXPIRATION 04/30/2022
THIS WORK WAS PREPARED BY ME OR
UNDER MY SUPERVISION
SIGNATURE
1/8" = 1'-0"
0 16'8'4'
PLAN
NORTH
KEY PLAN
SCALE: NONE
M A
T C
H L
IN
E
A D
D E
D P
A D
D E
M O
L
IT
IO
N
/2
/2
G
\1
R p l H
V A
C S y s
U S
A rm y M u se u m
F t
D e R u ss y\ D ra w in g s\ R u n n in g S e t\
M _1
P A
R T
IA
L
S T F
LR
M
E C
H A
N
IC
A L
D E M
O
LI
T
IO
N P
LA
N
.d w g
/2 /2
:5 :1
A
M h e le n
B lu e b e a m
P D
F
P ri n te r
H ig h R e s.
p c3
:1
| S-504.pdf |
| 468335_GC001XXX |
| 468335_S-504XXX |
| M_101 PARTIAL 1ST FLR MECHANICAL DEMOLITION PLAN.pdf |
| M_101 PARTIAL 1ST FLR MECHANICAL DEMOLITION PLAN |
| Layout |
File details come from the government source that posted it. Updated .