Consolidated Questions 2_8.4.2020.xlsx
XLSX spreadsheet 57 KB Posted
- Solicitation number
- 89243120RSC000051
- Issued by
-
Department of Energy
About this file
This federal solicitation seeks proposals for the operations and maintenance of the Oak Ridge Federal-Integrated Communication Network. Services include maintenance of analog, digital, and Voice over IP telecommunications systems across 500 facilities in and around Oak Ridge, Tennessee. The anticipated performance period is five years consisting of a one-year base period and four one-year options. Products and services required include maintenance of legacy equipment such as 5ESS switches as well as Cisco and Avaya VoIP systems. The solicitation includes attachments providing equipment inventories, workload histories, and pricing templates to assist offerors.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Consolidated Questions 4_8.19.2020.xlsx | XLSX spreadsheet | |
| 89243120RSC000051_Amendment 0004.pdf | ||
| 89243120RSC000051_Amendment 0003.pdf | ||
| Consolidated Questions 3_8.10.2020.xlsx | XLSX spreadsheet | |
| 89243120RSC000051_Amendment 0002.pdf | ||
| Consolidated Vendor Questions_1.xlsx | XLSX spreadsheet | |
| 89243120RSC000051_Amendment 0001.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Vendor Questions #1_7.24.2020
| # | RFP Section/ Exhibit/Attachment | Page # | Vendor Question | Government Response | |
| 1 | Section H | DOE-H-2070 | 57 | Section DOE-H-2070 lists Project Manager as Key Position. However, RFP page 91, Section 952.215-70 Key Personnel (DEC 2000) (b) list Program Manager as the Key personnel. Please confirm that these two citations reference the same position and/or clarify the correct title. | At a minimum, the Government considers the on-site project/program manager as Key Personnel. It is up to the contractor on whether they label the on-site person in that key position. |
| 2 | Section H | DOE-H-2067 | 57 | The Government advises that it will provide onsite facilities for at least 12 contractor personnel, and ‘Additional office space may be provided by the Government as necessary for contract performance. The Contractor shall not acquire or lease any office space without the prior written approval of the Contracting Officer.’ Can the Government confirm that all ORF-ICN O&M contract staff will be furnished with office space and equipment such that the offeror’s cost proposal need not allocate funds for furnishing office space at any point throughout the contract? | The only government furnished office space in located at 9702-1. This office space is to support the service center, telecommunications managment system, and central office. |
Section 4.0 of PWS states, "The Government will provide office space, land line phones, computers and furniture for Contractor employees located at Building 9702-1, which includes the CSC, the main CO, and the TMS functions. All other resources required are the responsibility of the Contractor."
| 3 | Section H | DOE-H-2067 | 57 | Will the Government provide warehouse space for equipment/materials/sparing? | No | |
| 4 | Section L | DOE-L-2012 | 117-121 | Is the offeror free to add worksheets to the Excel pricing file to enhance or clarify the cost details for the total overall price? | Yes | |
| 5 | Section L | DOE-L-2012(g)(7) | 120 | ‘Cost/price information is required for subcontracts in the same format and level of detail as required of the offeror.’ There are some aspects of the costing requirement for which this instruction makes little sense. Typically distinction is made between major and minor subcontractors for costing purposes, where major subs (e.g., >20% or 25% share) are required to submit costing at the same level of detail as the prime, while minor subs are not. | ||
| Does the Government truly intend that any subcontractor, regardless of size/percent share, must submit a complete Cost or Price Proposal? | This applies to major or critical subcontractors. | |||||
| 6 | Section L | DOE-L-2012(g)(7) | 120 | Please clarify how the subcontractors should submit their proprietary (sealed) information if they do not want to submit to the prime offeror? | Subcontractors can submit an e-mail directly to the to the points of contact identified in the soliciation. | |
| 7 | Section J - Attch J-1- PWS | General | Are all switches covered under a current maintenance agreement? | Yes | ||
| 8 | Section J - Attch J-1- PWS | General | Are there office spaces for the contractor at each facility or centralized from one area and dispatched out? | The only government furnished office space in located at 9702-1. This office space is to support the service center, telecommunications managment system, and central office. |
Section 4.0 of PWS states, "The Government will provide office space, land line phones, computers and furniture for Contractor employees located at Building 9702-1, which includes the CSC, the main CO, and the TMS functions. All other resources required are the responsibility of the Contractor."
9 Section J - Attch J-1- PWS 2.0 Last paragraph Appendix D 4
| 55 | Reference "ASO". Please provide division of estimated workload for the ASO services, specifically services provided by Customer Service Center (CSC) Staff, and services provided by Inside Plant personnel. Do CSC Staff have privileges assigned so they can log-in to switches and PBXs, to make administrative type changes (e.g. feature changes)? | The contractor is responsible for proposing the solution. Historical data is provided in the PWS. | ||||
| 10 | Section J - Attch J-1- PWS | 2.0 | 6 | Reference "Non-Routine". Please provide estimated workload data for boring services. | The estimated workload for non-routine services could not be determined, which is why there are considered non-routine. Non-routine services fall under the cost-reimbursable CLIN. | |
| 11 | Section J - Attch J-1- PWS | 2.0 | 6 | Reference "Non-Routine". Please provide estimated workload data for tree trimming services. | The estimated workload for non-routine services could not be determined, which is why there are considered non-routine. Non-routine services fall under the cost-reimbursable CLIN. | |
| 12 | Section J - Attch J-1- PWS | 2.0 | 6 | Reference "Non-Routine". Please provide estimated workload data for road cutting services. | The estimated workload for non-routine services could not be determined, which is why there are considered non-routine. Non-routine services fall under the cost-reimbursable CLIN. | |
| 13 | Section J - Attch J-1- PWS | 2.0 | 6 | Reference "Non-Routine". Please provide estimated workload data for pole setting services. | The estimated workload for non-routine services could not be determined, which is why there are considered non-routine. Non-routine services fall under the cost-reimbursable CLIN. | |
| 14 | Section J - Attch J-1- PWS | 2nd to last paragraph. | 9 | Are all ASOs completed by CSC personnel, or are some completed by Inside Plant Switch Technicians? If by both, please provided division of estimated workload for clarification. |
Do incumbent CSC personnel have administrative privileges on the 5ESS, Aura and CS1000 switches, to make ASO updates/changes?
| Are the incumbent CSC personnel qualified to perform administrative updates/changes? | The contractor is responsible for proposing the solution. Historical data is provided in the PWS. | ||||
| 15 | Section J - Attch J-1- PWS | 2nd to last paragraph. | 9 | The PWS states that ASOs include "equipment purchases". Please clarify the Contractors responsibilities for equipment purchases. |
[A] For example, is the Contractor required to research vendors and their prices and inventory to determine best price and availability?
[B] Is the Contractor required to obtain COR/STR approval prior to purchase?
[C] Is the Contractor required to purchase the equipment with our own funds?
[D] Will the Contractor be reimbursed for the cost of equipment purchases, including shipping?
[E] Is the Contractor required to receive and store the equipment until the SO is worked?
[F] Will the Contractor be provided a secure equipment/supply storage area?
[G] Is the Contractor required to order, receive, and/or store any other parts, supplies, materials, etc. to perform daily TT and SO work? Please provide estimated workload data for all these services.
[A] Yes [B] Yes [C] Yes [D] Yes [E] Yes [F] No, the government will not provide parking/storage for vehicles or equipment.
[G] Yes, see historical data for workload estimates.
| 16 | Section J - Attch J-1- PWS | 3.1.A/B/C. | 10 | The PWS states that Contractor personnel are required to maintain skills and "certifications", as well as "possess certificates, licenses and permits as required by the state, county, city, and other local jurisdictions". However, many certifications (switching and voicemail equipment O&M training, CompTIA Security+, CCNA, etc.) are not required by state, county, city, and other local jurisdictions. | ||
| Please provide a list of all "certifications" required by the DOE, for performance under this contract. | It is the contractos resonsibility to stay current on all requirements of jurisdictions where work is performed. It is also the contractors resposibility to utilize best business practices to ensure compatent, trained personel based on contractor's approach to meeting contractual requirements. Any DOE required certifiations will be stated in applicable DOE Orders identied in Attachement J-5 of the solicitation. | |||||
| 17 | Section J - Attch J-1- PWS | 3.1 B | 10 | Is the incumbent currently trained and qualified in the installation, configuration, and operation of the systems at each site? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 18 | Section J - Attch J-1- PWS | 3.1 C | 10 | Does the incumbent currently possess the required certificates, licenses and permits to perform the proposed work? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 19 | Section J - Attch J-1- PWS | 3.1 C | 10 | Contractor and sub-contractor personnel performing under the contract shall possess certificates, licenses, and permits as required by the state, county, city, and other local jurisdictions.’ Will the Government describe or enumerate any such certificates, licenses, and permits that may be required by the state, city, or county? | It is the contractos resonsibility to stay current on all requirements of jurisdictions where work is performed. It is also the contractors resposibility to utilize best business practices to ensure compatent, trained personel based on contractor's approach to meeting contractual requirements. Any DOE required certifiations will be stated in applicable DOE Orders identied in Attachement J-5 of the solicitation. | |
| 20 | Section J - Attch J-1- PWS | 3.1 D | 10 | Are the CAD drawings currently up to date? | Yes, to the best of the Government's knowledge, the CAD drawings are complete and accurate. | |
| 21 | Section J - Attch J-1- PWS | 3.2.D | 10 | Is the incumbent CAD Drafter(s) qualified to create and maintain CAD engineering drawings of the telecommunications cable plant? |
Is the CAD software, all required hardware (e.g. computer, large monitor, printer, plotter, etc.) and supplies (e.g. paper, toner/ink, etc.) provided by the Government? If not, please clarify the Contractor's responsibilities.
What CAD software/version is currently in use? The Government is not in a position to disclose the qualifications on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS.
Contractor shall provide all equipment/software to support the CAD requirement.
Current CAD software is Bently Microstation V8i / TELCO.
| 22 | Section J - Attch J-1- PWS | 3.2.D | 10 | What is the status of the current CAD drawings (e.g. all required drawings are 100% complete and accurate, 80% complete and accurate, 50%, etc.)? | ||
| How many OSP CAD drawings are there of the fiber and cabling between buildings? | To the best of the Government's knowledge, the CAD drawings are complete and accurate. There are currently 500 CAD drawings total. | |||||
| 23 | Section J - Attch J-1- PWS | 3.2 | 10 | Is there a service catalog currently in place? If so, will the Government provide current available services? | No, there is not a "servcies" catalog. | |
| 24 | Section J - Attch J-1- PWS | 3.2 I,J | 10 | What format are the reports to be presented in? | Varies depending on report type | |
| 25 | Section J - Attch J-1- PWS | 3.2 L | 10 | Section states: "Ensure coordination and development of applicable agreements and permits with local, state and federal agencies." Is this a reference for items the contractor must do on behalf of the government? If that is the case, is the contractor responsible for negotiating (if applicable) on behalf of the Government? Is the contractor responsible for covering any costs associated with attaining permits on behalf of the Government? | This reference is for items that the contractor must have in place to meet contractual requirements. For example, if a permit is required to bury a cable, it is the contractors responsibility to obtain such permit. | |
| 26 | Section J - Attch J-1- PWS | 3.2.Q | 11 | Is there currently an up to date catalog? If so, is it currently web-based? | There is a current, web based catalog. | |
| 27 | Section J - Attch J-1- PWS | 3.2.Q | 11 | Is the contractor solely responsible for developing and maintaining the web based catalog or does the contractor work with the Government to develop, maintain, and update the catalog? | Maintaining the cataglog is the contractors responsibility. | |
| 28 | Section J - Attch J-1- PWS | 3.2.Q | 11 | Is the contractor responsible for negotiating discounts for CPE? | Yes | |
| 29 | Section J - Attch J-1- PWS | 3.2.Q | 11 | Is the web-based catalog of approved CPE developed, including pricing? What is the current status of the catalog (e.g. 100% complete and accurate, 80% complete and accurate, 50%, etc.)? | The current catalog does not include pricing. To the best of the government's knowledge, the catalog is complete and accurate. | |
| 30 | Section J - Attch J-1- PWS | 3.3 A | 11 | Will there be parking/storage provided for vehicles and equipment? Will there be any cost associated with parking/storage? | The government will not provide parking/storage for vehicles or equipment. This is the contractors responsbility. | |
| 31 | Section J - Attch J-1- PWS | 3.5 F | 11 | Section states: "Within 90 calendar days of award, provide an Equipment Integrated Logistics Plan to cover the issue of sparing to include methodology for providing needed spares and protection for the network to meet". The sentence appears to be cut off. Will the Government provide the remaining portion of the sentence? | The cell was not expanded. …. Meet required service delivery goals. | |
| 32 | Section J - Attch J-1- PWS | 3.5.F | 11 | The requirement text ends at the end of line 2 (..for the network to meet…). Please provide the remaining text. | The cell was not expanded. …. Meet required service delivery goals. | |
| 33 | Section J - Attch J-1- PWS | 3.5.F | 11 | It appears the statement prematurely ends ‘…providing needed spares and protection for the network to meet….’ Will the Government please review and clarify the requirement? | The cell was not expanded. …. Meet required service delivery goals. | |
| 34 | Section J - Attch J-1- PWS | 3.6.H | 11 | Is the "required timeframe" for the resolution of Incidents (Trouble Tickets) the timeframes listed in 3.11.2.B, 3.11.3.B, and 3.11.4.A? | The response timeframes are listed in 3.11.2B, 3.11.3B, 3.11.4A | |
| 35 | Section J - Attch J-1- PWS | 3.11.4.A | 13 | Are the incumbent Technicians qualified to perform all O&M services on all paging systems and Public Address (PA) systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services that meet the PWS. | |
| 36 | Section J - Attch J-1- PWS | 3.11.4.A | 13 | Are the incumbent Technicians qualified to perform all O&M services on all E-911 systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 37 | Section J - Attch J-1- PWS | 3.12.A | 13 | Are all cable records maintained at the DCO in Building 9702-1, or are separate cable records maintained for each customer at their locations (e.g. OSTI Building 1916-T1, ORISE Building 4500, etc.)? | Cable records are maintained at a central location, not at each customer location. | |
| 38 | Section J - Attch J-1- PWS | 3.12.A | 13 | What is the status of the current cable records (e.g. all required cable records are 100% complete and accurate, 80% complete and accurate, 50%, etc.)? | To the best of the Government's knowledge, the cable records are complete and accurate. | |
| 39 | Section J - Attch J-1- PWS | 13.3.13 | 13 | Is the Contractor only required to locate Government-owned cable, or is the Contractor required to locate commercial telephone cables, cable TV coax, etc.)? | Only ORF-ICN cable plant. | |
| 40 | Section J - Attch J-1- PWS | 13.3.13 | 13 | Do all direct buried and underground cables have tracer wire? | No, all do not have 'tracer wire' per say. | |
| 41 | Section J - Attch J-1- PWS | 13.3.13 | 13 | What is the required timeframe for the Contractor to complete cable locates? | Normal locate ticket is 3 business days; emergency ticket is 2 hours. | |
| 42 | Section J - Attch J-1- PWS | 13.3.13 | 13 | Please provide estimated workload data for cable locates, preferably by CLIN. | An estimated 480 physical cable locates are perfomred annually. | |
| 43 | Section J - Attch J-1- PWS | 3.13-B | 13 | How many cable locates are performed annually by the telecommunications contractor at ORF-ICN? | An estimated 480 physical cable locates are perfomred annually. | |
| 44 | Section J - Attch J-1- PWS | 3.15 B and D | 13-14 | Section 3.15 B states ‘Perform quarterly vulnerability scans of system infrastructure, or whenever system changes occur.’ |
3.15 D states ‘Perform testing at a minimum Vulnerability scans (weekly)…’.
[A] Please clarify at which interval the contractor is to perform vulnerability scans, weekly or quarterly?
| [B] Does DOE provide the necessary vulnerability scanning software? | Frequency of weekly and biweekly has been removed. The Cyber Security Testing plan will determine the required frequency. | |||||
| 45 | Section J - Attch J-1- PWS | 3.15 D | 13 | Does the contractor have to provide the penetration testing software, or will that be provided by DOE? | Contractor is responsible for defining the penetration testing and provide the tools to perform the work. | |
| 46 | Section J - Attch J-1- PWS | 3.13 B, | ||||
| Appendix D | 13 | Are cable locates captured in the Service Order Column or under another column? | Cable locates are not included in Appendix D. | |||
| 47 | Section J - Attch J-1- PWS | 3.13-B | 13 | For clarification, the contractor is responsible for performing cable locates on Government property and is responsible for coordinating cable locates with Tennessee's One Call for locates off of Government property. Is that correct? | The contractor is responsible for all ORF-ICN cable locates. The contractor must also subscribe to Tennessee's One Call. | |
| 48 | Section J - Attch J-1- PWS | 3.17-A, B | 14 | Are there clear lines of delineation between this proposed contract work and the non-contract IT work? | The intent is for clear lines of delineation between this proposed contract work and the non-contract IT work. With multiple programs/sites and varying solutions, it is imparative for the contractor to ensure system specific operatonal documents with roles and responsibilities defined is agreed to and understood. | |
| 49 | Section J - Attch J-1- PWS | 3rd Paragraph | 16 | [A] Does the Government provide the Contractor with office space, phones, computers and/or furniture at any other building, on or off the ORR? |
[B] Does the Government provide the Contractor with secure parking space for Contractor-owned vehicles, trailers, and other equipment?
[C] Does the Government provide the Contractor with any secure interior warehouse/storage space for spare equipment, materials, parts and/or supplies?
[D] Does the Government provide the Contractor with any secure exterior storage space (often referred to as a "Cable Yard")? [A]No, 9702-1 only [B] No [C] No [D] No
| 50 | Section J - Attch J-1- PWS | 4th Paragraph | 16 | Is the Contractor required to provide "Operators" as part of this contract? If so, what are the requirements (e.g. qualifications, duties, responsibilities, number of consoles/desks, work hours, etc.)? | Contractor is responsible for meeting Customer Service Center requirements as defined in Section 4.1.8 |
| 51 | Section J - Attch J-1- PWS | 4.0 | 16 | Is this the only contractor provided space? Is there office space at all locations or just Bldg. 9702-1? | 9702-1 Only |
| 52 | Section J - Attch J-1- PWS | Diagram | 17 | [A] What does "NA" stand for? What does "DLC" stand for? |
[B] Which off-site facilities have a digital or VoIP PBX, and/or Adtran Multiplexer & DLC?
[C] What equipment/systems are at the ETTP?
[D] Please confirm that the Y-12 NSC site has both Cisco and Avaya VoIP UC systems, because a Cisco system is not mentioned in Section 10. [A] NA is part of a builidng name NA 1513 E, DLC stands for Digital Loop Carrier.
[B] [C] ETTP for Y-12 NSC has Avaya, Adtran systems in place [D] Cisco VoIP system referenced in the drawing is part of the ORT, Federal Building Comples system. Y-12 NSC does not have a VoIP system currently.
| 53 | Section J - Attch J-1- PWS | 4.1 | 19 | ORR Shared Requirements. Can the PWS be updated to correct omitted numbering: 4.1.7 | PWS udated to correct numbering from section 4.1.7 - 4.1.13. See Solicitation Amendment 0002 for revised PWS. |
| 54 | Section J - Attch J-1- PWS | 4.1.1 | Please provide details about the FOTS, specifically: |
(A) the number of feet/miles of Single Mode (SM) aerial cable,
(B) the number of feet/miles of Multi Mode (MM) aerial cable,
(C) the number of feet/miles of direct buried SM cable,
(D) the number of feet/miles of direct buried MM cable,
(E) the number of feet/miles of underground SM cable in duct, and
| (F) the number of feet/miles of underground MM cable in duct. | The FOTS consist of single mode fiber only. Total amount of FOTS fiber is currenlty 412,033 feet. This is a mix of aerial and underground. This is the FOTS fiber depicted in the ORF-ICN infrastructure diagram on page 17. | ||||
| 55 | Section J - Attch J-1- PWS | 4.1.1 | 19 | Please provide details about the copper cable plant, specifically: |
(A) the number of feet/miles of aerial copper cable and the pair sizes (e.g. 900 pair),
(B) the number of feet/miles of direct buried copper cable and the pair sizes, and
| (C) the number of feet/miles of underground copper cable in duct and the pair sizes. | There is no copper cable plant that is part of the FOTS, section 4.1.1. | |||||
| 56 | Section J - Attch J-1- PWS | 4.1.1 | 19 | Is the Contractor required to enter manholes or other confined spaces in order to inspect and/or Operate and Maintain (O&M) the FOTS or copper cable plant? If so, please provide the number of manholes and/or other confined spaces; the Contractor's inspection, O&M and remove/replace responsibilities, and any local restrictions or requirements. | The contractor is responsible to enter manholes for FOTS support as defined in the PWS. The current count of manholes that support the FOTS is 32. Confined space entry procedures must be followed when enterying the confined space. Equipment/material replacement will be done on a cost reimbursement basis. | |
| 57 | Section J - Attch J-1- PWS | 4.1.1 | 19 | Is the Contractor required to access, inspect, O&M and/or remove/replace handholes in order to inspect and/or O&M the FOTS or copper cable plant? If so, please provide the number and type of handholes; and the Contractor's inspection, O&M, and remove/replace responsibilities. | The contractor is responsible for accessing handholes for FOTS support as defined in the PWS. The current count of handholes that support the FOTS is 15. Any removal or replacement that is performed by the contractor will be done on a cost reimbursement basis. | |
| 58 | Section J - Attch J-1- PWS | 4.1.1 | 19 | Is the Contractor required to access, inspect, O&M and/or remove/replace any pedestals in order to inspect and/or O&M the FOTS or copper cable plant? If so, please provide the number and type of pedestals; and the Contractor's inspection, O&M, and remove/replace responsibilities. | The contractor is resonsible for accessing pedestals for FOTS support as defined in the PWS. Any removal or replacement that is performed by the contractor will be done on a cost reimbursement basis. | |
| 59 | Section J - Attch J-1- PWS | 4.1.1.A | 19 | Are the incumbent Technicians qualified to perform all required services to O&M the FOTS and copper cable plant? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 60 | Section J - Attch J-1- PWS | 4.1.2-B | 19 | What is meant by maintain contractual arrangements? Is the contractor responsible for negotiating contracts for the Government? | Contractor is responisble to establishing/negotiating their own subcontracts/agreements with other vendors. Contractor shall provide external voice and data connectivity under the contract, which is how it is currently done. No, contractor will not negotiate contracts for the Government. The contractor will only negotiate their own subcontracts/agreements. | |
| 61 | Section J - Attch J-1- PWS | 4.1.4 | 19 | What is meant by maintain contractual relationships? | Subcontract, Agreements - See response above. | |
| 62 | Section J - Attch J-1- PWS | 4.1.5-A | 19 | Are there any contractor costs associated with maintaining agreements (fees, services costs, etc.) with the City of Oak Ridge to continue use of utility poles? | Yes | |
| 63 | Section J - Attch J-1- PWS | 4.1.5 | 19 | ‘Maintain agreement with the City of Oak Ridge, Tennessee to continue use of utility poles to support aerial routing of FOTS and copper cable plant.’ Please quantify the number of utility poles and the current amount of aerial cables (i.e., miles of cable by type and count)? | The current number of City of Oak Ridge poles in the use agreement is unknown at this time. |
The amount of aerial cable by type and count is not available. However, for a reference, in addition to the FOTS totals provided (of which 67,084 feet are in townsite), townsite currently has and additional 152,196 feet of copper and 9,091 feet of fiber. As stated with the FOTS totals, this is a combination of aereale and underground cable plant.
| 64 | Section J - Attch J-1- PWS | 4.1.5 | 19 | Are there any O&M responsibilities for additional telephone pole, antennas, or public address speakers not owned by the City of Oak Ridge, Tennessee, within the scope of this PWS? If so, will the Government provide information regarding size and extent of support required? | There are also Governemnt owned poles that currently support aerial routing of both FOTS and copper cable plant. Contractor's responsibiltiy if to provide operations and maintenance of the cable plant systems. |
| 65 | Section J - Attch J-1- PWS | 4.1.5 | 19 | Is the contractor responsible to perform inspections and maintain utility poles? | Contractor is responsible for the monitoring of poles to ensure they are in a usable state. The maintaining of the pole would be the done by the pole owner. |
| 66 | Section J - Attch J-1- PWS | 4.1.5 | 19 | [A] Is the Contractor required to inspect the City of Oak Ridge poles and/or pole routes? If so, how often are these inspections required? |
[B] If a pole requires repair or replacement, who is responsible to perform the services, the City of Oak Ridge or the Contractor?
[C] How many City of Oak Ridge poles are being used to support the aerial FOTS and copper cable plant?
| [D] Are any Government-owned poles being used to support the aerial FOTS and copper cable plant? If so, how many Government-owned poles are being used, and what is the Contractor's responsibilities for the Government-owned poles? | [A] The contractor is responsible for periodic inspections of pole routes that the ORF-ICN outside plant utilizes. Depending on the pole route, the contractor should utlize best business practices to determine how often the route shoud be viewed/inspected. [B] If a pole requires repair/replacement, it is the pole owners responsibility. [C]XX poles are currently being utilized. [D] Government owned poles are also utilized. The contractor's responsibility is to notify the government should any pole appear to need repair/replacement. | |||||
| 67 | Section J - Attch J-1- PWS | 4.1.6 | 19 | Do the incumbent Technicians have all of this solicitation's required system certifications and security/IA qualifications to perform all Central Office (CO) O&M services? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 68 | Section J - Attch J-1- PWS | 4.1.6 L | 19 | Please clarify the Contractor's specific responsibilities to O&M generators, (e.g. tests, inspections, refueling, cleaning, preventive maintenance, corrective maintenance, etc.). | The contractor is responsible for the O&M, testing, as well as addressing operational and performance issues. | |
| 69 | Section J - Attch J-1- PWS | 4.1.6 L | 19 | Please clarify the Contractor's specific responsibilities to O&M HVAC systems, (e.g. tests, inspections, cleaning, preventive maintenance, corrective maintenance, etc.) | The contractor is responsible for the O&M, testing, as well as addressing operational and performance issues. | |
| 70 | Section J - Attch J-1- PWS | 4.1.6 L | 19 | For clarification, in regards to the O&M of the battery and generator backup systems, is the contractor responsible for the routine O&M and testing of the equipment? Does the Government maintain a separate maintenance agreement to address operational or performance issues? | The contractor is responsible for the O&M, testing, as well as addressing operational and performance issues. | |
| 71 | Section J - Attch J-1- PWS | 4.1.6 L | 19 | Are the backup power and HVAC systems supported by contract staff or are they supported by third party maintenance agreements? | This equipment is currently maintained under a maintenance agreement by the prime contractor. See RFP Attachment L-5 Price Model, Exhibit K for list of current maintenance agreements. | |
| 72 | Section J - Attch J-1- PWS | 4.1.7 | 19 | Can the Government please clarify their intent for this section as it is missing. | PWS updated to correct numbering from section 4.1.7 - 4.1.13. See Solicitation Amendment 0002 for revised PWS. | |
| 73 | Section J - Attch J-1- PWS | 4.1.8.A | 19 | What are the normal duty days and hours for other Contractor staff? | The contractor is responsible for their approach which includes duty hours of other contractor staff required to meet requirements. The duty hours for the Customer Service Center is idenfified in the PWS section 4.1.7 A. | |
| 74 | Section J - Attch J-1- PWS | 4.1.8 K | 20 | Is the contractor responsible for negotiating terms for the Government to maintain the agreements with Compunetix? If not, what is meant by "maintain agreement"? | Contractor is responsible for establishing their own agreement to ensure equipment/software is sufficiently maintained. | |
| 75 | Section J - Attch J-1- PWS | 4.1.8.L | 20 | Is the contractor responsible for negotiating terms for the Government to maintain the agreements with T-Metrics? If not, what is meant by "maintain agreement"? | Contractor is responsible for establishing their own agreement to ensure equipment/software is sufficiently maintained. | |
| 76 | Section J - Attch J-1- PWS | 4.1.8.L | 20 | The requirement is to ‘Maintain an agreement with T-Metrics for PhoneGroups Console System support.’ This maintenance agreement is not listed in the Maintenance Agreement Table on tab ‘Exhibit K_SW License & Equip PM’ in Attachment L-5, Price Model. Should this pricing be included with the other maintenance agreements? | This requirement has been removed from the PWS. | |
| 77 | Section J - Attch J-1- PWS | 4.1.8/9 | 19/20 | Do the incumbent Customer Service Center (CSC) personnel have the system and IA/security qualifications and certifications for performing all CSC services, to include updating and maintaining all required data in TMS for this solicitation? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 78 | Section J - Attch J-1- PWS | 4.1.9 B | 20 | Is the contractor responsible for negotiating terms for the Government to maintain the agreements with Professional Computing Resources? If not, what is meant by "maintain agreement"? | Contractor is responsible for establishing their own agreement with Professional Computing Resources to cover applicable system. | |
| 79 | Section J - Attch J-1- PWS | 4.1.9 | 20 | What is the current status of the data that is supposed to be maintained in TMS (e.g. 100% complete and accurate, 80% complete and accurate, 50%, etc.)? | To the best of the Government's knowledge, the TMS data is complete and accurate. | |
| 80 | Section J - Attch J-1- PWS | 4.1.10 | 20 | Please provide workload data for after-hours maintenance/repair (e.g. average number of after-hour responses per month/year). | This information is not available. | |
| 81 | Section J - Attch J-1- PWS | 4.1.10 | 20 | Does after hours call out work require approval before responding and performing work? | If an after hours call out requires work to be completed on OT to meet the contractual requirement, it does not require pre approval prior to working. However, an immediate notifcation to the appropriate COR/STR should be sent and followed up on during normal business hours. | |
| 82 | Section J - Attch J-1- PWS | 4.2 | 21 | For major upgrades and modernization projects (i.e.: replacement for 5E) will the government pay for any required training on the new equipment? | The Governement understands that training on a new system, as a result of modernization, that is not under the contract may result in a price adjustment. | |
| 83 | Section J - Attch J-1- PWS | 4.2 | 21 | If the DOE replaces legacy equipment/systems with new equipment/systems, will the Government pay for Contractor personnel to attend any necessary training and obtain any necessary certifications so they can O&M the new equipment/systems? | The Governement understands that training on a new system, as a result of modernization, that is not under the contract may result in a price adjustment. | |
| 84 | Section J - Attch J-1- PWS | 5.0 | 22 | Is the current user base still the initial 600? If not, what is the current user base? | The system has not grown past the initial 600 user base that it was sized. | |
| 85 | Section J - Attch J-1- PWS | 5.0 | 22 | The system can support up to 50,000 users. What has been and what is the expected rate of growth per year? | The system has not grown past the initial 600 user base that it was sized. It is anticipated that majority of the Federal Building Complex will eventually migrate to this system. | |
| 86 | Section J - Attch J-1- PWS | 5.0 | 22/23 | Are the incumbent Technicians BICSI certified to perform premise fiber and copper cable installations and O&M services? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 87 | Section J - Attch J-1- PWS | 5.0 | 23 | Paragraph states: "At ORT locations, the standard wiring plan for new buildings and building modification may be performed by the Contractor, Government, or other Prime Contractor at the discretion of the Government." If it is decided for the contractor to perform this, what type of workload will the requirement equate to? | See Historic data with wiring counts; Appendix D – Historical Data Averages | |
| 88 | Section J - Attch J-1- PWS | 5.0 | 23 | Paragraph states: "In such cases where there is a separate data network for VoIP that is maintained by the Contractor, the Contractor is responsible for all aspects of O&M of the network." What type of network switches are utilized? | The type of network switches could vary and even change. At the present time, Cisco switches are being utilized. | |
| 89 | Section J - Attch J-1- PWS | 5.0 | 23 | Paragraph states: "In such cases where there is a separate data network for VoIP that is maintained by the Contractor, the Contractor is responsible for all aspects of O&M of the network." Will this contract require Network Administrator/Technician positions? | The contractor is responsible for their approach to include the skill set required to meet spec requirements. | |
| 90 | Section J - Attch J-1- PWS | 5.0 | 23 | ‘In such cases where there is a separate data network for VoIP that is maintained by the Contractor, the Contractor is responsible for all aspects of O&M of the network.’ Does the DOE currently have maintenance agreements in place with the OEMs for these data networks? If so, is it the contractor’s responsibility to maintain these agreements? | The DOE does not have any agreements in place directly with vendors, this is all done through the telecom contractor. The contractor is to establish and maintain such agreements as they are needed to sure requirements of the PWS are met. required under the PWS. | |
| 91 | Section J - Attch J-1- PWS | 5.0, Last Paragraph | 24 | [A] Is the Contractor responsible for "customer training"? If so, what training is the Contractor responsible to provide? |
[B] Is the training requirement applicable to only the ORT (CLIN 5)?
[C] Is the Contractor responsible to pay for and/or provide customers with training materials?
[D] What type of training venue is required (e.g. classroom, virtual, one-on-one, etc.)?
[E] Please provide estimated workload data for customer training services. [A] Contractor training is "train the trainer" type application as well as assisting end users when new technology.
[B] Training refered to in this section is applicable to ORT only.
[C] If hard copy of training materials are required, those costs will fall under the Cost-Reimbursement CLIN.
[D] Type of training venue is train-the-trainer type.
[E] Training workload is included in service order numbers in Appendix D.
| 92 | Section J - Attch J-1- PWS | 5.1.1 | 25 | Is the bidder required to price a hardware upgrade in our proposal? | Per Section 5.1.4, yes hardware is to be included in the FFP. |
| 93 | Section J - Attch J-1- PWS | 5.1.2.A | 25 | Are the incumbent Technicians certified to perform all O&M services on Cisco VoIP equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. |
| 94 | Section J - Attch J-1- PWS | 5.1.4 | 25 | PWS 5.1.4 says: ‘Ensure ORT infrastructure is eligible for vendor support (e.g., must be within two major versions of vendor’s current version).’ Providing a firm fixed price to meet this requirement is impossible for the following reasons: |
- The frequency of vendor releases is unknown—it could be one new major version release per year or it could be no new releases at all over the life of the O&M contract.
- Some version upgrades are software only, while others could require wholesale additions or replacements of the hardware/servers.
- Other PWS sections have divergent requirements:
| o | PWS 5.1.4 is the only section that specifies that ‘Hardware upgrade[s] to support software upgrades are to be included.’ | |||||
| o | PWS sections 6.1.3 and 9.1.3 state: ‘Ensure [site] infrastructure is eligible for vendor support (e.g., within two major versions of vendor’s current version). Upgrades must be coordinated with COR.’ | |||||
| o | PWS 8.1.8 and 10.1.10 requires software to be within one major version of the current version and includes coordination with the STR. | |||||
| o | PWS 7.1.10 includes quarterly patching and specifies coordination with COR for major software upgrades only. | |||||
| o | PWS 7.1.8, 8.1.1, and 8.1.3 include ‘Support, operate, and maintain current [site] infrastructure including future system enhancements or upgrades.’ | |||||
| o | PWS sections 8.1.4, 10.1.6, and 10.1.10 include versions of ‘Ensure upgrades are performed in a timely manner to ensure no lapse in the ability to support new phone models as older phone models are EOL by Avaya.’ | |||||
| Given the diversity of system upgrade requirements, and because the costs of meeting the one- or two-major version requirements are wildly unpredictable, can these costs be included as an ODC in the Cost Reimbursable (Exhibit D), and not as a Firm-fixed price? | This costs shall be included under the fixed price for each site based on that site specific requirements. | |||||
| 95 | Section J - Attch J-1- PWS | 5.1.5 | 25 | Are the incumbent Technicians certified or otherwise formally trained to perform all O&M services on Cisco voicemail (VM) equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 96 | Section J - Attch J-1- PWS | 5.1.5 | 25 | Are the incumbent Technicians certified or otherwise formally trained to perform all O&M services on Octel VM equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 97 | Section J - Attch J-1- PWS | 5.1.5.B | 25 | The PWS requires a plan to to "...migrate all ORT VM accounts from OCTEL system to Cisco unified messaging…". |
When is the plan due?
Who should it be submitted to?
| Recommend including the ORT Voicemail Migration Plan with due date and distribution data in Attachment J-2, Reporting Requirements. | Plan should be submitted to CO and ORT COR six months after award. Attachment J-2 Reporting Requirements, Revision 01 has been updated to reflect this. | |||||
| 98 | Section J - Attch J-1- PWS | 5.1.5.B | 25 | The PWS refers to an OCTEL voicemail system and a Cisco unified messaging system. | ||
| Please provide details of these systems (e.g. ORT location, current configurations, capabilities, estimated timeframe for migration, etc.). | The OCTEL voicemail is an antiquated, infrastructure system that is still in operation until all users have migrated to the Cisco Unified Messaging or other viable voicemail sytem. The Cisco unified messaging system currently supports ORT Cisco VoIP users. | |||||
| 99 | Section J - Attch J-1- PWS | 5.1.4; 6.1.3;7.1.10; and 9.1.3 | 25; 28; 30; 41 | Ensure ORT (and OREM, ORISE, and OST) infrastructure is eligible for vendor support (e.g., must be within two major versions of vendors current version)." | ||
| Is all infrastructure related software current and within two major versions of vendor's current software? | PWS is correct. | |||||
| 100 | Section J - Attch J-1- PWS | 5.1.8 | 26 | The PWS references an Emergency Operations Center (EOC) at the Oak Ridge Townsite (ORT). Please identify the building where this EOC is located. | The referenced EOC is located in the Federal Building. | |
| 101 | Section J - Attch J-1- PWS | 5.1.8 | 26 | Please specify the requirements for 24/7 priority telecommunications support, as it applies to the ORT EOC. | Response to and support of the Emergency Operations Center telecom is required and is to be treated as an emergency corrective maintenance item. | |
| 102 | Section J - Attch J-1- PWS | 6.0 | 27 | Who is responsible for the Quality Assurance of the work provided by others that would become the responsibility of the contractor to provide O&M? | The Government assumes responsibility on the QA of work done outside the contract; however, the contractor is responsible for any QA done by them or their subcontractors under the contract | |
| 103 | Section J - Attch J-1- PWS | 6.1.4 | 28 | Section states: Work with STR to develop and implement plan to migrate all ORCC VM accounts from OCTEL". Should this be "…VM accounts from OCTEL to Cisco Unified Messaging (or other system) and coordinate implementation with the COR" (similar to other sections)? | Should read, "work with STR to develop and implement plan to migrate all ORCC Voicemails to Cisco Unified Messaging or another viable voicemail system" PWS has been updated. | |
| 104 | Section J - Attch J-1- PWS | 6.1.6 | 28 | The PWS references an EOC at the Oak Ridge Office of Environmental Management (OREM). Please identify the building where this EOC is located. | 6.1.6 has been removed from the PWS. See revised PWS. | |
| 105 | Section J - Attch J-1- PWS | 6.1.6 | 28 | Please specify the requirements for 24/7 priority telecommunications support, as it applies to the OREM EOC. | 6.1.6 has been removed from the PWS. See revised PWS. | |
| 106 | Section J - Attch J-1- PWS | 2nd Paragraph | 29 | Are the incumbent Technicians certified or otherwise formally trained to perform all O&M services on Avaya/ Nortel CS1000 equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 107 | Section J - Attch J-1- PWS | 2nd Paragraph | 29 | Are the incumbent Technicians certified or otherwise formally trained to perform all O&M services on Avaya Aura messaging equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 108 | Section J - Attch J-1- PWS | 7.1 | 30 | ORISE Specific Requirements. Can the PWS be updated to correct omitted numbering: 7.1.3 through 7.1.7? | PWS Updated to correct numbering from section 7. See Solicitation Amendment 0002 for revised PWS. | |
| 109 | Section J - Attch J-1- PWS | 4th and 7th Paragraphs | 32 | Are the incumbent Technicians certified to perform all O&M services on Avaya Aura VoIP equipment/systems, and associated equipment/systems (e.g. Comm Manager, Session Manager, Session Border Controller, G450 gateways, SAL, SLAMON and the Call Management System)? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 110 | Section J - Attch J-1- PWS | 4th Paragraph | 32 | Are the incumbent Technicians formally trained to perform all O&M services on Nortel Norstar PBX and Merlin key equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 111 | Section J - Attch J-1- PWS | Voicemail | 34 | Are the incumbent Technicians formally trained to perform all O&M services on Norstar CallPilot equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 112 | Section J - Attch J-1- PWS | 8.1.8 | 38 | Section states: Ensure ORNL infrastructure is eligible for vendor support (e.g., must be within one major versions of vendors current version)." Is all infrastructure related software current and within one major version of vendor's current software? | Yes | |
| 113 | Section J - Attch J-1- PWS | 8.1.9 | 38 | Are the incumbent Technicians certified to perform all O&M services on Avaya Esna voicemail equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 114 | Section J - Attch J-1- PWS | 8.1.8, 10.1.10 | 38, 45 | Per the PWS, ORNL and Y-12 NSC infrastructure must be ‘eligible for vendor support (e.g., within one major versions of vendor's current version)’. All other sites’ comparable requirements state ‘within two major versions.’ Please confirm that these different vendor support requirements are correct as published. | Yes, the PWS is correct. | |
| 115 | Section J - Attch J-1- PWS | 3rd Paragraph | 40 | The PWS states "Building 9701-2". Should this actually be "Building 9702-1"? | Yes, should state 9702-1. PWS has been updated to reflect the correct building number. | |
| 116 | Section J - Attch J-1- PWS | 9.0 | 40 | What is the distance between the STC facility locations located at 9714 Flannigan Loop Road and 1190 West Bear Creek Road? | Approximately 4.3 miles if driving. | |
| 117 | Section J - Attch J-1- PWS | 5th Paragraph | 42 | Are the incumbent Technicians qualified to perform installation, configuration, and all O&M services on Lucent 5ESS Switches and 5ESS Remotes? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 118 | Section J - Attch J-1- PWS | 10.1.3.D | 44 | What PBX equipment/systems are at K1650? | Avaya Aura/ Ad-Tran/ | |
| 119 | Section J - Attch J-1- PWS | 10.1.5.B | 44 | Are the incumbent Technicians certified or otherwise formally trained to perform all O&M services on Nortel and Avaya Aura Contact Center equipment/systems? | The Government is not in a position disclose the qualificatons on the incumbent contractor's personnel. Incumbent contractor is required to provide services and qualified personnel that meet the PWS. | |
| 120 | Section J - Attch J-1- PWS | 10.1.13 | 45 | Please provide make and model for all PA systems, as well as any ancillary PA equipment, that the Contractor must maintain. | Attachment J-3 to the PWS identifies equipment the contractor is required maintain under the contract. | |
| 121 | Section J - Attch J-1- PWS | 10.1.16 | 45 | The PWS references an EOC and a Y-12 NSC Operations Center. Please identify the building(s) where the EOC and Y-12 Operations Center are located. | K-1650 is the EOC and 9706-2 is the Y-12 Operations Center | |
| 122 | Section J - Attch J-1- PWS | 10.1.16 | 45 | Please specify the requirements for "elevated priority" telecommunications support, as it applies to the EOC and Y-12 Operations Center. | As stated, response to and support of the Y-12 NSC Operation Center and EOC telecommunications equipment is required and is to be handled as an emergency corrective maintenance item. | |
| 123 | Section J - Attch J-1- PWS | 10.1.18 | 46 | Please confirm that these requirements are only applicable to Y-12 NSC (CLIN 10). | Yes | |
| 124 | Section J - Attch J-1- PWS | 1st Paragraph | 47 | What is meant by "issuing the specified credit"? Please clarify the requirement. | Sentence has been revised to the following: |
This includes delivering the service, maintaining the service at specified Acceptable Quality Limit (AQL), measuring the Key Performance Indictor (KPI), and reporting on compliance.
| 125 | Section J - Attch J-1- PWS | 11.1 A | 47 | The provisioning interval for orders shall be measured in days from the SO submission date to the completion date." Are these days only working days M- F or are weekends included? | These are business days, not calendar days | |
| 126 | Section J - Attch J-1- PWS | SLA Table, Footnote | 47 | Does the Government calculate the AQL for each KPI annually, or monthly? | Monthly | |
| 127 | Section J - Attch J-1- PWS | Appendix D | Page 55 | Can the Government specify what areas/buildings/facilities are part of CLIN 1? | ||
| What is the workload history data for CLIN 1? | The PWS Appendix 5 has been updated with the correct CLINs. | |||||
| 128 | Section J - Attch J-1- PWS | Appendix D | Page 55 | Can the Government specify what areas/buildings/facilities are part of CLIN 3? | ||
| What is the workload history data for CLIN 3? | The PWS Appendix 5 has been updated with the correct CLINs. |