892-043 Ft Rosecrans - Bid Doc - Plans - pt3.pdf
PDF 15 MB Posted
- Solicitation number
- 36C78622B0019
About this file
This document provides details for an Invitation for Bid for road and sewer improvement projects at Fort Rosecrans National Cemetery in San Diego, California. The solicitation number is 36C78622B0019 and is being issued by the Department of Veterans Affairs National Cemetery Administration. The IFB seeks bids for roads improvement under project number 892-045 and sewer improvement under project number 892-043. Bids are due by the specified closing date. The work includes repairs and upgrades to roads and sewers at the cemetery to improve access and operations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 892-043 Ft Rosecrans - Add No 1 - Plans - pt3.pdf | ||
| 892-043 Ft Rosecrans - Add No 1 - revised sheets.pdf | ||
| 892-043 Ft Rosecrans - Add No 1 - Specifications.pdf | ||
| SITE VISIT LIST.pdf | ||
| 892-043 Ft Rosecrans - Memo Addendum No 1 - 2022-08-29.docx | DOCX document | |
| RFI Responses.pdf | ||
| 892-043 Ft Rosecrans - Add No 1 - Plans - pt2.pdf | ||
| 892-043 Ft Rosecrans - Add No 1 - Plans - pt1.pdf | ||
| 36C78622B0019 0003.docx | DOCX document | |
| 36C78622B0019 0002.docx | DOCX document | |
| 36C78622B0019 0001.docx | DOCX document | |
| 220707 Ft Rosecrans CA 892 043 Sewer 045 Roads Specifications.pdf | ||
| IFB Lump Sum Division Spreadsheet - Ft Rosecrans 36C78622B0019.xlsx | XLSX spreadsheet | |
| 36C78622B0019_1.docx | DOCX document | |
| 892-043 Ft Rosecrans - Bid Doc - Plans - pt1.pdf | ||
| P09 - 220714 Ft Rosecrans CA Roads 892-043-045 IFB Scope of Work.docx | DOCX document | |
| Wage Determination.txt | TXT text file | |
| 892-043 Ft Rosecrans - Bid Doc - Plans - pt2.pdf | ||
| TOC for Plans.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_d et ai ls
.d w g ed it:
at hi el e sa ve d:
6/
/2
:0
AM
p lo t:7
/1 4/
2:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
CD101
CIVIL SITE DETAILS 1
AT MT 67
MATCH EXIST.
(TYP)
EXPANSION JOINT (TYP)
NO. 4 REINFORCING RODS (3)
CONTINUOUS IN CROSS GUTTER
EXPANSION JOINT.
18"
APPROX.
EXPANSION
JOINT (TYP)
VARIABLE
7"
3' MIN.
1-1/2"
MIN.
SCALE:1
VEHICULAR CONCRETE PAVEMENT DETAIL
NTS SCALE:4
CONCRETE CURB DETAIL
NTS SCALE:5
ASPHALT PATCH FOR CURB CONSTRUCTION
NTSSCALE:2
PEDESTRIAN CONCRETE DETAIL
NTS SCALE:3
ASPHALT PAVEMENT DETAIL
NTS
TACK COAT
6" MIN. COMPACTED AGGREGATE BASE
2" BITUMINOUS ASPHALT BASE COURSE
1 1/2" BITUMINOUS ASPHALT WEAR COURSE
APPROVED SUBGRADE
4" CONCRETE
6" MIN. COMPACTED AGGREGATE BASE
APPROVED SUBGRADE
4"
6"
#4 REBAR @ 24" O.C. SPACING EACH WAY
APPROVED SUBGRADE
8" CONCRETE PAVEMENT
12" AGGREGATE BASE
1 1/4" min.
1 3/4" max.1/8" to 1/4"
1/8"
SAWCUT OR TOOLED
POLYURETHANE
SEALANT
1/2" NON-EXTRUDING
PRE-MOLDED COMPRESSIBLE
MATERIAL
TOOLED JOINT
2" min.
2 1/4" max.1/8" to 1/4"
1/8"
SAWCUT OR TOOLED
PEDESTRIAN CONCRETE
VEHICULAR CONCRETE
PAVEMENT
SCALE:8
CONTROL JOINT DETAIL
NTS
SCALE:9
EXPANSION JOINT DETAIL
NTS
NOTES:
1.) PAVEMENT SHALL COMPLY WITH GEOTECHNICAL REPORT
2.) CONTROL JOINTS TO BE SPACED A MAXIMUM OF 12'.
3.) SEE PLANS FOR MORE DETAILED JOINT LAYOUT. NOTES:
1.) PAVEMENT SHALL COMPLY WITH GEOTECHNICAL REPORT
B612
AT ALL TRENCHES 2#4 REINFORCING RODS
SHALL BE PLACED IN THE LOWER PORTION OF
THE CURB 20 FEET IN LENGTH.
2#4 REINFORCING RODS AT CATCH BASINS NO
LESS THEN 10 FEET IN LENGTH.
SLOPE 3/4"
PER FT.
1/2" RAD.
6"
3" RAD.
1/2" RAD.
.5
6"
2" 2"
2"
7"
8" 12"
SCALE:11
IRRIGATION HEAD TEMPORARY AND PERMANENT LOCATION
NTS
EXISTING LATERAL
EXISTING HEAD
LOCATION
TEMPORARY IRRIGATION
HEAD LOCATION DURING CONSTRUCTION
(SALVAGED EXISTING IRRIGATION HEAD),
TEE OFF LATERAL, CAP AFTER REMOVAL
10' MAX
4' TYP
NOTE:
THE CONTRACTOR IS RESPONSIBLE FOR
TEMPORARY IRRIGATION OF ALL SOD
UNTIL IT IS FULLY ESTABLISHED PER
SPECS. THE CONTRACTOR MAY NOT
UTILIZE THE EXISTING IRRIGATION
SYSTEM TO KEEP THE NEW SOD
CONTINUALLY MOIST IN DROUGHT
CONDITIONS. THIS MAY BE
ACCOMPLISHED WITH A WATER TRUCK
EQUIPPED WITH THE APPROPRIATE
HOSES AND NOZZLES.
SCALE:7
CONCRETE VALLEY GUTTER DETAIL
NTS
3/4" /FT
SCALE:10
ASPHALT PATCHING DETAIL
NTS
ASPHALT PATCH
1 12" BITUMINOUS WEAR COURSE
2" BITUMINOUS BASE COURSE
COMPACTED AGGREGATE BASE
APPROVED SUBGRADE
3" MIN.
6" MIN.
6"
NOTES:
1. ASPHALT PATCH SHALL BE 6" WIDER ON EITHER SIDE OF TRENCH EXCAVATION.
SAWCUT AND REMOVE EXISTING ASPHALT TO PROVIDE CLEAN MATCH POINT.
2"
SCALE:13
HEAVED PAVEMENT REMOVAL
NTS
TREE ROOT
REMOVE HEAVED PAVEMENT TO
TOP OF UNDERLYING TREE ROOTREMOVE HEAVED PAVEMENT TO LINE
OF ADJACENT UNHEAVED PAVEMENT
TREE ROOT
SMALLER ROOT HEAVING LARGER ROOT HEAVING
LINE OF ADJACENT PAVEMENT
TAPER REMOVAL BACK
TO PAVEMENT GRADE
SCALE:12
PEDESTRIAN CURB RAMP DETAIL
NTS
2' MIN.
FULL DEPTH SAWCUT
REMOVE ASPHALT PAVEMENT TO ALLOW
FOR CONCRETE CURB CONSTRUCTION.
ASPHALT PATCH TO MATCH EXISTING SECTION
EXISTING AND
PROPOSED CURB
NOTE: INSTALL PRE-MOLDED EXPANSION
MATERIAL AT MATCHPOINT WITH ALL COLUMNS,
FOOTINGS, AND BUILDINGS.
NOTES:
1. ALL HEADS AT BACK OF CURB TO BE REPLACED WITH TORO T7P #9 NOZZLE, NEW
SWING JOINTS AND OLDCASTLE M305BA SPRINKLER COLLARS.
2. ADJUST SPRINKLER HEADS AFTER INSTALLATION TO NOT SPRAY ON ROADWAYS.
NOTE: TRUNCATED DOME PANELS SHALL BE DARK GREY IN COLOR. SUBMIT FOR COR APPROVAL.
SCALE:14
TRAFFIC RATED HANDHOLE
NTS
6" MIN. CONC
ALL SIDES
6"
TRAFFIC RATED HANDHOLE
REINFORCED 1/2" GALVANIZED STEEL PLATE COVER
WITH NON-SLIP TEXTURED SURFACE
INSIDE DIMENSIONS VARY
MATCH EXISTING
(18"x24" MIN.)
CLEAN CRUSHED ROCK SUMP
3" MIN.
MATCH TO WITHIN 1/8" OF
ADJACENT PAVEMENT SURFACE
NOTE: INSTALLATION SHALL MEET REQUIREMENTS OF CALTRANS STANDARD PLAN ES-8B
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_d et ai ls
.d w at hi el d:
6/
/2
:0 lo t:7
/1 4/
2:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
CD102
CIVIL SITE DETAILS 2
AT MT 68
SCALE:4
PIPE BOLLARD DETAIL
NTS
12"
6"
GRANULAR
FILL
COMPACTED
BACKFILL
"DIA." DENOTES OUTSIDE
DIAMETER OF PIPE
DIA+12" MIN.
COMPACTED
BACKFILL
12"
AGGREGATE BASE.
"DIA." DENOTES OUTSIDE
DIAMETER OF PIPEDIA+12" MIN.
IMPROVED PIPE
FOUNDATION
PIPE FOUNDATION & BEDDING IN
POOR SOILS
PIPE FOUNDATION & BEDDING IN
GOOD SOILS
DIA.
DIA.
SCALE:3
PIPE BEDDING DETAIL
NTS
BUTT JOINTS. ENDS OF ROCK/COMPOST
LOG TO BE SECURELY CLOSED TO
PREVENT LOSS OF OPEN GRADED
AGGREGATE FILL. SECURE WITH 50 PSI ZIP
TIE. (TYP.)
GEOTEXTILE SOCK BETWEEN 4-10 FEET LONG
AND 4-6 INCHES IN DIAMETER. SEAM TO BE
JOINED BY TWO ROWS OF STITCHING WITH A
PLASTIC MESH BACKING OR PROVIDE A HEAT
BONDED SEAM (OR APPROVED EQUIVALENT).
FILL LOG WITH AN OPEN GRADED AGGREGATE
CONSISTING OF SOUND DURABLE PARTICLES
OF COARSE AGGREGATE.
SCALE:5
BIO-ROLL DETAIL
NTS
MAIN LINE
IN LINE CLEANOUT END OF LINE CLEANOUT
SEWER
24"x24"
CONCRETE
COLLAR
DROP LID
TYPE
ENCASE PVC WYE IN CONCRETE
MIN. 1/3 CU. YDS.
ENCASE PVC BENDS IN CONCRETE
MIN. 1/3 CU. YDS.
ONE PIECE 4" PVE
CLEANOUT RISER
100' MAX
100' MAX
4" PVC
6"x4" RED
LONG SWEEP
90° BEND
4" PVC
6"x4" RED
LONG SWEEP
90° BEND
WYE
" M
IN
18"
TYP.
PAVEMENT SECTION OR SURFACE
TO MATCH
WARNING TAPE PLACED 6" ABOVE PIPE
CALTRANS SAND BACKFILL
PE FORCEMAIN W/ TRACER WIRE
TAPED TO TOP OF PIPE
SCALE:1
PVC CLEANOUT DETAIL
NTS SCALE:2
TYPICAL FORCEMAIN TRENCH DETAIL
NTS
SCALE:6
CATCH BASIN MANHOLE
NTS
SCALE:7
STORM SEWER MANHOLE
NTS SCALE:8
STORM PIPE TERMINATION AT CONCRETE SWALE
NTS
SECTION
PLAN
SEE C3 STORM SCHEDULE
CASTING
PRECAST INVERT MUST BE 1/2 DIAMETER OF
PIPE AND BENCHES SHOULD BE SLOPED 2"
TOWARD INVERT. MATCH 0.8THS POINT OF
MAIN LINE SEWER AND LATERIAL BRANCH.
MANHOLE STEPS SHALL BE PLACED
SO THAT OFFSET VERTICAL PORTION
OF CONE IS FACING DOWNSTREAM.
NEENAH FRAME AND COVER OR
EQUAL LETTERED "SANITARY
SEWER" OR "STORM SEWER" WITH 2
CONCEALED PICK HOLES
CONCRETE ADJUSTMENT RINGS WITH
FULL BED OF MORTAR BETWEEN EACH.
TOTAL ADJUSTMENT MIN. 4" MAX. 14"
PRECAST ECCENTRIC CONE SECTION
MANHOLE STEPS, NEENAH R1981N
OR EQUAL, 16" ON CENTER.
COPOLYER POLYPROPYLENE
PLASTIC (PSI-PF) AND ALUMINUM
STEPS APPROVED.
ALL JOINTS IN PRECAST MANHOLE
SECTIONS TO HAVE "O" RING RUBBER
GASKETS.
PRECAST MANHOLE SECTIONS
PIPE SHALL BE CUT OUT FLUSH
WITH INSIDE FACE OF WALL.
NOTE: KOR-N-SEAL MANHOLE OR EQUAL
CONSIDERED ACCEPTABLE ALTERNATE.
ALL DOG HOUSES SHALL BE GROUTED
ON BOTH INSIDE AND OUTSIDE.
MINIMUM THICKNESS OF PRECAST
BASE IS 6" FOR 14' DEEP OR LESS, AND
INCREASES 1" IN THICKNESS FOR
EVERY 4' OF DEPTH GREATER THAN 14'.
5"
4'-0"
4'-0"
VARIES
12"-16"
VARIES
"B"
"A"
SECTION A
12" HDPE PIPE
REGRADE TO PROVIDE PIPE COVER
EXISTING TOP OF CURB
BASE OF CURB
FLOWLINE
SAWCUT & REMOVE
CONCRETE
SECTION B
EX
IS
TI
N
G B
O U
N D
AR
Y
W
AL
L
16"
3' 3'
4" M
IN
SAWCUT & REMOVE
CONCRETEFLOWLINE
BASE OF CURB
TOP OF CURB
RECONSTRUCT CURB TO
PROVIDE COVER OVER PIPE
TOP OF CURB OVER PIPE
48"-#3 REBAR PLACED ON
CENTER, DIRECTLY BEHIND
CURB BOX IN CONCRETE CURB.
GROUT WITH AN
APPROVED BONDING
AGENT ADDITIVE. SHALL
BE PLACED BETWEEN
AND OUTSIDE OF THE
ADJUSTING RINGS.
3 MIL
POLYETHYLENE
WRAP AROUND
THE OUTSIDE OF
CONCRETE CURB
MIX.
CONCRETE CURB
MIX SHALL
INCORPORATE THE
ENTIRE CASTING
AND ADJUSTING
RINGS.
ONLY CONCRETE OR
METAL SHIMS SHALL
BE USED FOR
LEVELING CASTING.
2" ADJUSTING RINGS
MINIMUM - 2
MAXIMUM - 6
NEENAH 3067 OR
APPROVED EQUAL
FINISHED GRADE
PLASTIC OR ALUMINUM STEPS
TO MEET ASTM 478
POURED OR PRECAST
CONCRETE BASE (3000 P.S.I.)
TYPE II COVER SLAB
(4000 P.S.I.)
MANHOLE MUST
MEET ASTM 478
TAR OR GROUT SEAL
GROUT BENCH
& FLOW LINE
POURED OR PRECAST
CONCRETE BASE (3000 P.S.I.)
STANDARD CATCHBASIN
SUMPED CATCHBASIN
4'-0"
5"
6"5' - 4" MINIMUM
VA
R
IE
S
6" 24" X 36"
1"
3" MINIMUM
6"5'-4" MINIMUM
D
4" STEEL PIPE
CONCRETE FOOTING
FILL PIPE WITH CONCRETE A FINISH
ROUNDED TOP 1" PROUD OF PIPE
12" DIA.
SCALE:9
TRAFFIC RATED HANDHOLE DETAIL
NTS
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_d et ai ls
.d w at hi el d:
6/
/2
:0 lo t:7
/1 4/
2:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
CD103
CIVIL SITE DETAILS 3
AT MT 69
SCALE:1
FORCEMAIN CONNECTION MANHOLE DETAIL
NTS
BALL VALUE
BALL VALUE
SEE TEE
DETAIL
TEE ASSEMBLIES
SEE NOTE AND
DETAIL
FL
O
W
FLOWFLOW
TEE ASSEMBLY
FL
O
W
FLOW
12x8x18 SOLID
CONC. BLOCK
FABRICATED METAL BRACKET
FOR TEE ASSEMBLY SUPPORT
ANCHORED TO CONC. BLOCK
REFERENCE NOTES:
1 ROMAC PART #R511035003507 WITH NBR GASKETS
2 3" X 21" PIPE (ONE END THREADED)
3 3" X 3" X 3" THREADED TEE (150 PSI)
4 3" X 6" NIPPLE (BOTH ENDS THREADED)
5 3" S.S. BALL VALVE
6 3" X 4" NIPPLE (BOTH ENDS THREADED)
7 3" CAM & GROOVE MALE ADAPTOR BY 3" N.P.T. (BRASS)
8 3" CAM & GROOVE DUST CAP (BRASS)
9 3" X 10" SDR21 PVC PIPE
10 3" SCH 40 PVC SOCKET GLUE COUPLING
11 3" X (1.25" OR 1.5") SCH 40 PVC SOCKET BUSHING
91011 6 4 2 1 9 10 11
TEE
12x8x18 SOLID
CONC. BLOCK
TEE ASSEMBLY DETAIL
TEE DETAIL
NOTE:
BALL VALVE AND TEE ASSEMBLIES ARE TO BE
INSTALLED VERTICALLY, BUT ARE SHOWN
HORIZONTALLY FOR CLARITY.
NOTE:
BALL VALVE AND TEE ASSEMBLIES ARE TO BE
INSTALLED VERTICALLY, BUT ARE SHOWN
HORIZONTALLY FOR CLARITY.
84" PRECAST CONCRETE MANHOLE
.5
.5
SLAB TOP AND COVER DETAIL
42" DIA. FRAME AND COVER
W/ 24" DIA. OFFSET INNER COVER
FORCEMAIN ALIGNMENT
FORCEMAIN ALIGNMENT
PRECAST CONCRETE TOP SLAB
6" CONCRETE BASE
SLOPE FLOOR TO SINGLE LOW POINT FOR CLEANING
TEE ASSEMBLY
FLOW
REFERENCE NOTES:
1 ROMAC PART #R511035003507 WITH NBR GASKETS
2 3" X 10" PIPE (ONE END THREADED)
3 3" X 3" X 3" THREADED TEE (150 PSI)
4 3" X 3" SCH 40 PVC WYE
5 3" S.S. BALL VALVE
6 3" X 4" NIPPLE (BOTH ENDS THREADED)
7 3" CAM & GROOVE MALE ADAPTOR BY 3" N.P.T. (BRASS)
8 3" CAM & GROOVE DUST CAP (BRASS)
9 3" X 10" SDR21 PVC PIPE
10 3" SCH 40 PVC SOCKET GLUE COUPLING
11 3" X (1.25" OR 1.5") SCH 40 PVC SOCKET BUSHING
12 3" SCH 40 PVC UNION - F.P.T.
13 3" SCH 40 PVC 45° BEND
SCALE:2
FORCEMAIN CLEANOUT MANHOLE
NTS
48" PRECAST CONCRETE MANHOLE
2 1 9 10 11
9 12
PARTS LIST
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_d et ai ls
.d w at hi el d:
6/
/2
:0 lo t:7
/1 4/
2:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
CD104
CIVIL SITE DETAILS 4
AT MT 70
SCALE:1
STREET SECTION A-A (RAISE ROAD DEMO)
NTS
VARIES
REMOVE EXISTING CONCRETE CURB REMOVE EXISTING
CONCRETE CURB
SCALE:3
STREET SECTION C-C (MILL & OVERLAY DEMO)
NTS
SCALE:2
STREET SECTION B-B (FULL DEPTH REPLACEMENT DEMO)
NTS
EXISTING AGGREGATE BASE TO
REMAIN
MILL 0.5" @ ℄
VARIES VARIES
VARIES
REMOVE EXISTING CONCRETE CURB
REMOVE EXISTING
CONCRETE CURB
EXISTING AGGREGATE BASE TO
REMAIN
VARIES VARIES
MILL 1" @ GUTTER
SCALE:4
STREET SECTION D-D (MILL & OVERLAY DEMO - EXISTING LEFT CURB TO REMAIN)
NTS
VARIES
REMOVE EXISTING CONCRETE CURB
REMOVE EXISTING
CONCRETE CURBVARIES VARIES
REMOVE ALL EXISTING BITUMINOUS
PAVEMENT AND AGGREGATE BASE
MILL 0.5" @ ℄
VARIES
EXISTING CONCRETE
CURB TO REMAIN
REMOVE EXISTING
CONCRETE CURB
EXISTING AGGREGATE BASE TO
REMAIN
VARIES VARIES
MILL 1" @ GUTTER
ALL PAVEMENT TO REMAIN EXCEPTING SELECT REMOVAL
OF HEAVED PAVEMENT PER DETAIL 13 ON SHEET CD101
NOTES:
1. EXISTING PAVEMENT TO REMAIN IN PLACE. LIMITED AREAS OF BROKEN
PAVEMENT TO BE REMOVED WHERE ROOTS HAVE CAUSED HEAVING.
REMOVE BROKEN PAVEMENT BY HAND ASSISTED BY SELECTIVE USE OF
PNEUMATIC HAMMER TOOL.
2. REMOVE CONCRETE CURB & GUTTER FROM BOTH SIDES OF THE ROADWAY.
3. CONTRACTOR SHALL TAKE CARE TO PROTECT & MINIMIZE DISTURBANCE
TO EXISTING TREE ROOTS.
4. FILL VOID FROM CURB REMOVAL WITH AGGREGATE BASE UP TO LEVEL OF
EXISTING PAVEMENT AND COMPACT TO SPECIFICATION.
MILL 1" @ GUTTER
MILL 1" @ GUTTER
NOTES:
1. REMOVE ALL EXISTING PAVEMENT, CONCRETE CURB & GUTTER, AND
AGGREGATE BASE MATERIAL.
2. SUBCUT SUBGRADE TO PLAN GRADES TO PREPARE FOR NEW AGGREGATE
BASE MATERIAL.
NOTES:
1. REMOVE EXISTING CONCRETE CURB & GUTTER FROM BOTH SIDES OF THE
ROADWAY. RECONSTRUCT CURB & GUTTER PER 3/CD105 PRIOR TO
MILLING EXISTING PAVEMENT.
2. MILL EXISTING BITUMINOUS PAVEMENT. MILLING SHALL TAPER IN DEPTH
FROM A FULL 1" @ CURB TO APPROXIMATELY 12 " @ CENTERLINE.
3. NO CURB IS PRESENT ON EASTERN DRIVE RIGHT OF CENTERLINE FROM
STA 13+29 TO 14+04 AND 15+45 TO END OF ALIGNMENT.
NOTES:
1. REMOVE EXISTING CONCRETE CURB & GUTTER FROM ROADWAY SIDE
OPPOSITE OF THE SIDEWALK & COLUMBARIA WALL. SIDEWALK & CURB IN
FRONT OF COLUMBARIA WALL SHALL REMAIN. CONTRACTOR TO ROTECT
AS NECESSARY.
2. MILL EXISTING BITUMINOUS PAVEMENT. MILLING SHALL TAPER IN DEPTH
FROM A FULL 1" @ CURB TO APPROXIMATELY 12 " @ CENTERLINE.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_d et ai ls
.d w at hi el d:
6/
/2
:0 lo t:7
/1 4/
2:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
CD105
CIVIL SITE DETAILS 5
AT MT 71
SCALE:1
STREET SECTION E-E (RAISE ROAD INSTALL)
NTS
SCALE:3
STREET SECTION G-G (MILL & OVERLAY INSTALL)
NTS
SCALE:2
STREET SECTION F-F (FULL DEPTH REPLACEMENT INSTALL)
NTS
NEW VERTICAL CONCRETE CURB
NEW CURB AGGREGATE BASE TO
EXTEND 1' BEHIND CURB
3" BASE COURSE
CLASS 2 AGG.3"ASPHALT PAVEMENT
PER 4/CD101
NEW CURB AGGREGATE
BASE TO EXTEND
1' BEHIND CURB
3" 3"
SCALE:4
STREET SECTION H-H (MILL & OVERLAY INSTALL - EXISTING LEFT CURB TO REMAIN)
NTS
VARIES
2% 2%
NEW VERTICAL CONCRETE CURB
PER 6/CD101
NEW VERTICAL CONCRETE CURB
NEW CURB AGGREGATE BASE TO
EXTEND 1' BEHIND CURB
2" BASE COURSE
ASPHALT PAVEMENT
1.5" WEAR COURSE ASPHALT
PAVEMENT PER 4/CD101
NEW CURB AGGREGATE
BASE TO EXTEND
1' BEHIND CURB
6" 6"
VARIES
2% 2%
NEW VERTICAL CONCRETE CURB
PER 6/CD101
6"
6" COMPACTED AGGREGATE BASE
NEW VERTICAL CONCRETE CURB
1" ASPHALT OVERLAY
VARIES
VARIES VARIES
NEW VERTICAL CONCRETE CURB
PER 6/CD101
NEW VERTICAL CONCRETE CURB
PER 6/CD101
1" ASPHALT OVERLAY
1"
VARIES
VARIES VARIES
EXISTING CONCRETE
CURB TO REMAIN
CONSTRUCT 3" BITUMINOUS
PAVEMENT SECTION OVER 3"
AGGREGATE BASE OVER EXISTING
PAVEMENT
MIRAFI MPG-G4 GEOTEXTILE
FABRIC OR APPROVED EQUAL
(SEE PLANS FOR LOCATIONS)
ALL PAVEMENT TO REMAIN PER DETAIL 1/CD104
1"
AS
NEEDED AS
NEEDED
NOTES:
1. CONSTRUCT NEW AGGREGATE BASE SECTION FOR CONCRETE CURB.
INSTALL NEW CONCRETE CURB & GUTTER INDICATED.
2. INSTALL MIRAFI PGM-G4 GEOTEXTILE FABRIC IN AREAS OF ROOT DAMAGE,
INDICATED ON THE PLANS. ADHERE TO EXISTING PAVEMENT SURFACE
WITH BITUMINOUS TACK COAT APPLIED @ 0.15 GAL/SY.
3. CONSTRUCT NEW AGGREGATE BASE SECTION OVER EXISTING PAVEMENT
& GEOTEXTILE FABRIC.
4. CONSTRUCT 2" BITUMINOUS PAVEMENT BASE COURSE.
5. CONSTRUCT 1" BITUMINOUS PAVEMENT WEAR COURSE AT SAME TIME AS
OVERLAY TO PROVIDE UNIFORM SURFACE.
NOTES:
1. CONSTRUCT AGGREGATE BASE SECTION OVER PREPARED & APPROVED
SUBGRADE.
2. CONSTRUCT CONCRETE CURB & GUTTER.
3. CONSTRUCT 2" BITUMINOUS PAVEMENT BASE COURSE.
4. CONSTRUCT 1.5" BITUMINOUS PAVEMENT WEAR COURSE AT SAME TIME AS
OVERLAY TO PROVIDE UNIFORM SURFACE.
NOTES:
1. CONSTRUCT CONCRETE CURB & GUTTER PRIOR TO BITUMINOUS
PAVEMENT MILLING. DUE TO TAPERED MILLING, PROPOSED CENTERLINE
SHOULD BE APPROX. 0.5" HIGHER THAN EXISTING.
2. MILL PAVEMENT PER 3/CD104.
3. CONSTRUCT BITUMINOUS PAVEMENT OVERLAY AT SAME TIME AS
BITUMINOUS WEAR COURSE CONSTRUCTION TO PROVIDE UNIFORM
SURFACE THROUGHOUT ROAD LENGTH.
4. OMIT NEW CURB ON EASTERN DRIVE RIGHT OF CENTERLINE FROM STA
13+29 TO 14+04 AND 15+45 TO END OF ALIGNMENT.
NOTES:
1. CONSTRUCT CONCRETE CURB & GUTTER PRIOR TO BITUMINOUS
PAVEMENT MILLING, PROPOSED CENTERLINE SHOULD BE APPROX. 0.5"
HIGHER THAN EXISTING.
2. MILL PAVEMENT PER 4/CD104.
3. CONSTRUCT BITUMINOUS PAVEMENT OVERLAY AT SAME TIME AS
BITUMINOUS WEAR COURSE CONSTRUCTION TO PROVIDE UNIFORM
SURFACE THROUGHOUT ROAD LENGTH.
ADD/REPLACE AGGREGATE BASE FOR NEW CURB
INSTALL AS NECESSARY/DIRECTED BY COR
ADD/REPLACE AGGREGATE BASE FOR NEW CURB
INSTALL AS NECESSARY/DIRECTED BY COR
ADD/REPLACE AGGREGATE BASE FOR NEW CURB
INSTALL AS NECESSARY/DIRECTED BY COR
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_d et ai ls
.d w at hi el d:
6/
/2
:0 lo t:7
/1 4/
2:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
CD106
CIVIL SITE DETAILS 6
AT MT 72
SCALE:1
SILT FENCE DETAIL
NTS SCALE:2
EROSION CONTROL BLANKET DETAIL
NTS
SCALE:4
RAISE & REALIGN FLAT MARKER DETAIL
NTS
EXISTING MARKERS
EXISTING GRADE
PROPOSED GRADE
PROPOSED CURB
RELOCATED MARKERS
SEE DETAILS 4-6/CD106 FOR DETAILS
OF FLAT MARKER SUPPORT
SCALE:3
RAISE & REALIGN UPRIGHT MARKER DETAIL
NTS
PROPOSED GRADE
PROPOSED CURB
RELOCATED MARKERS
SEE DETAIL 3/CD106 FOR DETAIL
OF UPRIGHT MARKER SUPPORT
SCALE:5
RAISE & REALIGN FLAT MARKER DETAIL
NTS
SCALE:6
RAISE & REALIGN FLAT MARKER DETAIL
NTS
SCALE:7
RAISE GRADE ROAD SECTION - TYPICAL FLAT MARKER ADJUSTMENT (RAISE & REALIGN)
NTS
SCALE:8
MEMORIAL ISLAND GRADING - TYPICAL UPRIGHT MARKER ADJUSTMENT (RAISE & REALIGN)
NTS
AutoCAD SHX Text
NATIVE SOIL
AutoCAD SHX Text
COMPACTED CRUSHED AGGREGATE BACKFILL
AutoCAD SHX Text
UPRIGHT HEADSTONE
AutoCAD SHX Text
BASE AGGREGATE PER SYNTHETIC TURF SPEC
AutoCAD SHX Text
COMPACTED CRUSHED AGGREGATE BASE
AutoCAD SHX Text
NATIVE SOIL
AutoCAD SHX Text
HEADSTONE
AutoCAD SHX Text
SYNTHETIC TURF
AutoCAD SHX Text
TOP VIEW (SECTION)
AutoCAD SHX Text
FRONT VIEW (SECTION)
AutoCAD SHX Text
SIDE VIEW (SECTION)
AutoCAD SHX Text
COMPACTED CRUSHED AGGREGATE BACKFILL
AutoCAD SHX Text
UPRIGHT HEADSTONE ANCHOR
AutoCAD SHX Text
PLASTIC MARKER SUPPORT GRID, CONTINUOUS
AutoCAD SHX Text
SUBGRADE- SCARIFY, AMEND & RE-COMPACT- THROUGHOUT
AutoCAD SHX Text
AMENDED TOPSOIL
AutoCAD SHX Text
FLAT MARKER SET ON COMPACTED 1/4" MINUS LEVELLING SAND, TYP.
AutoCAD SHX Text
FINISH GRADE 1" BELOW MARKER
AutoCAD SHX Text
COMPACTED 3/4" MINUS AGGREGATE BASE
AutoCAD SHX Text NOTES: AMENDED TOPSOIL IS A HOMOGENOUS BLEND AMENDED TOPSOIL IS A HOMOGENOUS BLEND OF NATIVE TOPSOIL AND IMPORTED TOPSOIL. FLAT MARKER THICKNESS VARIES. VERIFY THICKNESS IN FIELD AND ADJUST MARKER SUPPORT SYSTEM AS REQUIRED.
AutoCAD SHX Text
COMPACTED 3/4" MINUS COMPACTED CRUSHED AGGREGATE BASE
AutoCAD SHX Text
FLAT MARKER SET ON 1/4" MINUS COMPACTED LEVELLING AGGREGATE
AutoCAD SHX Text PLASTIC MARKER SUPPORT GEOGRID, CONTINUOUS- FILL CELLS W/ AMENDED TOPSOIL AFTER SETTING MARKERS
AutoCAD SHX Text
CD106
AutoCAD SHX Text
AutoCAD SHX Text
CD106
AutoCAD SHX Text
AutoCAD SHX Text
AMENDED TOPSOIL THROUGHOUT
AutoCAD SHX Text
COMPACTED 3/4" MINUS AGGREGATE BASE
AutoCAD SHX Text
FLAT MARKER- 1" ABOVE FINISH GRADE, TYP.
AutoCAD SHX Text
COMPACTED 1/4" MINUS LEVELLING SAND
AutoCAD SHX Text
PLASTIC MARKER SUPPORT GRID
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
SUBGRADE- SCARIFY, AMEND & RE-COMPACT- THROUGHOUT
AutoCAD SHX Text
4" MIN. AMENDED TOPSOIL OVER AGGREGATE BACKFILL
AutoCAD SHX Text NOTES: AMENDED TOPSOIL IS A HOMOGENOUS BLEND AMENDED TOPSOIL IS A HOMOGENOUS BLEND OF NATIVE TOPSOIL AND IMPORTED TOPSOIL. FLAT MARKER THICKNESS VARIES. VERIFY THICKNESS IN FIELD AND ADJUST MARKER SUPPORT SYSTEM AS REQUIRED.
AutoCAD SHX Text
STATE OF CALIFORNIA
AutoCAD SHX Text
DEPARTMENT OF TRANSPORTATION
AutoCAD SHX Text
SILT FENCE FABRIC
AutoCAD SHX Text 1"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
STAPLE
AutoCAD SHX Text
PANEL B
AutoCAD SHX Text
WOOD POSTS
AutoCAD SHX Text
PANEL A
AutoCAD SHX Text
SILT FENCE FABRIC
AutoCAD SHX Text
WOOD POST
AutoCAD SHX Text
STAPLE
AutoCAD SHX Text
WOOD POST
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
TOE OF SLOPE
AutoCAD SHX Text
SEE TRENCH DETAIL
AutoCAD SHX Text
SILT FENCE FABRIC
AutoCAD SHX Text
WOOD POST
AutoCAD SHX Text
BACKFILL
AutoCAD SHX Text 1/16" Dia
AutoCAD SHX Text
3'-0" SETBACK (SEE NOTE 2)
AutoCAD SHX Text
(SEE NOTE 3)
AutoCAD SHX Text
(SEE NOTE 6)
AutoCAD SHX Text
SILT FENCE FABRIC (SEE NOTE 5)
AutoCAD SHX Text The down stream end of the temporary silt fence shall have the last 8' angled up slope. Setback dimensions may vary to fit field conditions. Posts to overlap and fence fabric to fold around each post one full turn. Secure fabric with 4 staples for each post. Posts shall be driven tightly together to prevent potential flow-through of sediment at the joint. The tops of the posts shall be secured to each other with wire. For each end post, fence fabric shall be folded around two posts one full turn and secured with 4 staples. Minimum of 4 staples shall be installed per post. Dimensions shown are typical. Maintenance openings shall be constructed in a manner to ensure that sediment is retained by the temporary silt fence. Joint sections shall not be placed at sump locations.
AutoCAD SHX Text
1. 2. 3. 4. 5. 6. 7. 8.
AutoCAD SHX Text
TEMPORARY WATER POLLUTION
AutoCAD SHX Text
CONTROL DETAILS
AutoCAD SHX Text
(TEMPORARY SILT FENCE)
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
SECTION A-A
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
TEMPORARY SILT FENCE
AutoCAD SHX Text
POST AT JOINTS
AutoCAD SHX Text
STAPLE DETAIL
AutoCAD SHX Text
TRENCH DETAIL
AutoCAD SHX Text
END POST DETAIL
AutoCAD SHX Text
SECTION
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 5'-0" Min 6'-0" Max
AutoCAD SHX Text
OPTIONAL MAINTENANCE OPENING (SEE DETAIL)
AutoCAD SHX Text
SILT FENCE FABRIC
AutoCAD SHX Text
SEE END POST DETAIL
AutoCAD SHX Text
SILT FENCE FABRIC
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
TOE OF SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
WOOD POST
AutoCAD SHX Text
FENCE ANGLED UP SLOPE (SEE NOTE 1)
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
TEMPORARY SILT FENCE
AutoCAD SHX Text
TAMPED BACKFILL SLOPE DIRECTION DIRECTION OF FLOW
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
SILT FENCE FABRIC
AutoCAD SHX Text 2'-0"±
AutoCAD SHX Text 8'
AutoCAD SHX Text 8'
AutoCAD SHX Text
WOOD POST
AutoCAD SHX Text
TOE OF SLOPE
AutoCAD SHX Text
END POSTS
AutoCAD SHX Text
SILT FENCE FABRIC
AutoCAD SHX Text
WOOD POST
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 45° Typ
AutoCAD SHX Text
OPTIONAL MAINTENANCE OPENING DETAIL
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
PANEL B
AutoCAD SHX Text
PANEL A
AutoCAD SHX Text STAPLE SPACING 8" Max
AutoCAD SHX Text
PERSPECTIVE
AutoCAD SHX Text
SILT FENCE PANELS AT JOINTS
AutoCAD SHX Text
2018 STANDARD PLAN T51
AutoCAD SHX Text 1-29-18
AutoCAD SHX Text T51
AutoCAD SHX Text
AutoCAD SHX Text
THE STATE OF CALIFORNIA OR ITS OFFICERS
AutoCAD SHX Text
OR AGENTS SHALL NOT BE RESPONSIBLE FOR
AutoCAD SHX Text
COPIES OF THIS PLAN SHEET.
AutoCAD SHX Text
THE ACCURACY OR COMPLETENESS OF SCANNED
AutoCAD SHX Text 1.
AutoCAD SHX Text Temporary fiber roll shown for reference purposes only.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
DETAIL C
AutoCAD SHX Text
KEY TRENCH AT TOP OF SLOPE
AutoCAD SHX Text 2'-0" Min
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
HINGE POINT TEMPORARY BLANKET FABRIC BACKFILL AND TAMP STEEL STAPLE
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
DETAIL D
AutoCAD SHX Text
KEY TRENCH AT TOE OF SLOPE
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
TEMPORARY
AutoCAD SHX Text
BLANKET FABRIC
AutoCAD SHX Text
TOE OF SLOPE
AutoCAD SHX Text
BACKFILL AND TAMP
AutoCAD SHX Text
STEEL STAPLE
AutoCAD SHX Text
DETAIL B
AutoCAD SHX Text
LONGITUDINAL BLANKET JOINT
AutoCAD SHX Text
TEMPORARY BLANKET FABRIC COVERED EDGE OVERLAPPING EDGE STEEL STAPLE
AutoCAD SHX Text 1'-0" Typ
AutoCAD SHX Text 1'-0" Typ
AutoCAD SHX Text
PREVAILING WIND
AutoCAD SHX Text
DETAIL A
AutoCAD SHX Text
STAPLE PATTERN
AutoCAD SHX Text
TEMPORARY BLANKET FABRIC
AutoCAD SHX Text 4'-0" Typ
AutoCAD SHX Text 2'-0" Typ
AutoCAD SHX Text 4'-0" Typ
AutoCAD SHX Text 2'-0" Typ
AutoCAD SHX Text
TAMPED BACKFILL SLOPE DIRECTION DIRECTION OF FLOW
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
STEEL STAPLE
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
DETAIL F
AutoCAD SHX Text
KEY TRENCH AT LOWER CONFORM
AutoCAD SHX Text TEMPORARY BLANKET FABRIC BACKFILL AND TAMP STEEL STAPLE TEMPORARY FIBER ROLL (SEE NOTE 1) UNDISTURBED SLOPE
AutoCAD SHX Text 6"
AutoCAD SHX Text
DETAIL E
AutoCAD SHX Text
KEY TRENCH AT UPPER CONFORM
AutoCAD SHX Text
SECTION
AutoCAD SHX Text UNDISTURBED SLOPE TEMPORARY FIBER ROLL (SEE NOTE 1) STEEL STAPLE BACKFILL AND TAMP TEMPORARY BLANKET FABRIC
AutoCAD SHX Text 6"
AutoCAD SHX Text
TEMPORARY BLANKET FABRIC
AutoCAD SHX Text
LOWER ENTRENCHMENT (KEY TRENCH AT TOE OF SLOPE SHOWN)
AutoCAD SHX Text
TEMPORARY BLANKET FABRIC
AutoCAD SHX Text
UPPER ENTRENCHMENT (KEY TRENCH AT TOP OF SLOPE SHOWN)
AutoCAD SHX Text
UNDISTURBED SLOPE
AutoCAD SHX Text
UNDISTURBED SLOPE
AutoCAD SHX Text
EMBANKMENT OR CUT SLOPE
AutoCAD SHX Text
STAPLE DETAIL
AutoCAD SHX Text
TEMPORARY EROSION CONTROL BLANKET ON SLOPE WITH VARIOUS KEY ENTRENCHMENTS
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
ISOMETRIC
AutoCAD SHX Text
TEMPORARY EROSION CONTROL BLANKET ON SLOPE
AutoCAD SHX Text 8"
AutoCAD SHX Text 2"
AutoCAD SHX Text
LONGITUDINAL BLANKET JOINT (SEE DETAIL B)
AutoCAD SHX Text
KEY TRENCH AT TOE OF SLOPE (SEE DETAIL D)
AutoCAD SHX Text
KEY TRENCH AT LOWER CONFORM (SEE DETAIL F)
AutoCAD SHX Text
KEY TRENCH AT UPPER CONFORM (SEE DETAIL E)
AutoCAD SHX Text
KEY TRENCH AT TOP OF SLOPE (SEE DETAIL C)
AutoCAD SHX Text
STAPLE PATTERN (SEE DETAIL A)
AutoCAD SHX Text
HINGE POINT
AutoCAD SHX Text
STEEL STAPLE
AutoCAD SHX Text
PREVAILING WIND
AutoCAD SHX Text
16 GAUGE STEEL WIRE
AutoCAD SHX Text
TEMPORARY WATER POLLUTION
AutoCAD SHX Text
CONTROL DETAILS
AutoCAD SHX Text
(TEMPORARY EROSION CONTROL BLANKET)
AutoCAD SHX Text
STATE OF CALIFORNIA
AutoCAD SHX Text
DEPARTMENT OF TRANSPORTATION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
2018 STANDARD PLAN T54
AutoCAD SHX Text 1-29-18
AutoCAD SHX Text T54
AutoCAD SHX Text
AutoCAD SHX Text
THE STATE OF CALIFORNIA OR ITS OFFICERS
AutoCAD SHX Text
OR AGENTS SHALL NOT BE RESPONSIBLE FOR
AutoCAD SHX Text
COPIES OF THIS PLAN SHEET.
AutoCAD SHX Text
THE ACCURACY OR COMPLETENESS OF SCANNED
NO
PARKING
NO
PARKING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_l
_l an d.
dw at hi el d:
6/
/2
2:
P
M lo t:7
/1 4/
:0
PM
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
LP101
LANDSCAPE PLAN
AT MT 73
VICINITY MAP
PLANTING SCHEDULE
TREES
Qty. Key Common & Botanical Names Cont, Mat. Size Ht./Spread Remarks
4 MEX New Zealand Christmas Tree 36" Box 35' / 35' Single, straight leader
Metrosideros excelsa No 'v' crotches
GROUNDCOVERS
Qty. Key Common & Botanical Names Cont. Remarks
40 AEC Emerald Carpet Manzanita 1 Gal. 12" / 42" Arctostaphylos x 'Emerald Carpet
Mat. Size Ht./Spread
MEX
AEC
MEX
AEC
MEX
AEC
MEX
AEC
N
0 20' 40'
1 SITE PLAN ENLARGEMENT
SCALE: 1" = 20'
N
0 20' 40'
N
0 20' 40'
3 SITE PLAN ENLARGEMENT
SCALE: 1" = 20'2 SITE PLAN ENLARGEMENT
SCALE: 1" = 20'
KEY NOTES
PROTECT EXISTING LANDSCAPED ROCK MULCH AND PLANT MATERIAL.
REPLACE DAMAGED PLANT MATERIAL IN KIND. REPLACE ROCK MULCH
THAT BECOMES CONTAMINATED WITH DEBRIS AND DIRT IN KIND, MATCH
EXISTING.
NEW FLOWER WATER STATION
INSTALL ROOT BARRIER PER DETAIL 7/LP501 ENTIRE PERIMETER OF
CURB WITHIN ISLAND PLANTING AREA.
LEGEND
EXISTING LANDSCAPED BEDS TO REMAIN
NEW SOD
NEW STAMPED COLORED CONCRETE
BEACH COBBLE - LARGE, 3 INCH MIN. DEPTH OVER
LANDSCAPE FABRIC, MATCH EXISTING
NEW TREES AND GROUND COVERS
RELOCATED GUARDRAIL
METAL LANDSCAPE EDGING
NEW FLOWER WATERING STATION
MATCH LINE 1/C101
M
AT
C H
L
IN
E 1/
C
MATCH LINE 2/C101
M
AT
C H
L
IN
E 2/
C
QTY
KEY
ID TAG
QUANTITY
KEY
SUCCULENTS
Qty. Key Common & Botanical Names Cont, Mat. Size Ht./Spread Remarks
114 DED San Diego Chalk Fingers 1 Gal. 8" / 12" Space 15" O.C.
Dudleya edulis
Plant Min. 12" from wall
DED
110 AFS Thread-leaf Agave 1 Gal. 12" / 12" Space 15" O.C.
Agave 'filifera ssp. schidigera
Plant Min. 12" Ft. from wall
Plant Min. 12" from wall
55 SCO Mexican Stonecrop 1 Gal. 4" / 12" Space 15" O.C.
Sedum confusum
72 DCO Cooper's Hardy Ice Plant 1 Gal. 6" / 24" Delosperma cooperi
Plant Min. 12" from wall
14 ASU Sunburst Aeonium 1 Gal. 18" / 24" Space 24" O.C.
Aeonium 'Sunburst'
Plant Min. 12" from wall
7 AVE Aloe Vera 1 Gal. 24" / 24" Space 24" O.C.
Aloe vera
ASU
EEL
DCO
AFS
CTE
DED
DCO
SCO
ASU
AFS
DCO
DED
AVE
EEL
DCO
AFS
AAS
SCO
DCO
DED
CTE
AFS
DCO
DED
Plant Min. 12" from wall
7 AAS Schwarzkopf Stonecrop 1 Gal. 36" / 24" Space 24" O.C.
Aeonium arboreum 'Schwarzkopf'
SHRUBS
Qty. Key Common & Botanical Names Cont, Mat. Size Ht./Spread Remarks
14 CTE Miniture Pine Tree 5 Gal. 36" / 24" Space 24" O.C.
Crassula tetragona Plant Min. 12" Ft. from wall
Plant Min. 12" from wall
74 EEL Mexican Snowball 1 Gal. 14" / 12" Space 15" O.C.
Echeveria elegans
Plant Min. 18" from wall
Space 42" O.C.
Space 24" O.C.
INSTALL BEACH COBBLE
AROUND LIFT STATION COVER
REPLACE ARTIFICIAL TURF AT
DIRECTOR'S LODGE PER 8/LP501
GENERAL NOTES
1. ALL DISTURBED AREAS NOT SCHEDULED TO RECEIVE PAVEMENT
OR LANDSCAPING SHALL BE RESTORED. AREAS WITHIN
CEMETERY BOUNDARIES SHALL RECEIVE SOD. AREAS ALONG
CABRILLO MEMORIAL DRIVE SHALL RECEIVE HYDROSEED
APPLICATION OF CALTRANS SEED SPECIFICATION 1.
NOTE: ALL PLANTING BEDS TO RECEIVE BARK MULCH SURFACING.
SEE DETAIL 9/LP501 FOR TYPICAL
ISLAND PLANTING LAYOUT
2"
CENTER TREE IN HOLE, UPRIGHT
SINGLE STRAIGHT LEADER TREE TIE SECURED TO STAKE. SECURE TO
TREE WITH ANTI-CHAFFING MATERIAL. ALLOW
FOR MOVEMENT OF TREE.
WRAP TREE WITH TREE WRAPPING
MATERIAL AS SPECIFIED TO 1ST
BRANCH
5' MIN. CLEAR AT EDGE OF TRUNK
(EDGE OF GROUNDCOVERS AT FULL
MATURITY, WALK EDGE, ALL CURBS
OR TURF AREA)
(3) 10FT LONG TREE STAKES DRIVEN
A MIN. 2' BELOW GRADE
3" DEPTH SHREDDED BARK
MULCH
4" HEIGHT TAMPED WATER BASIN
AT EDGE OF PLANTING PITFINISHED GRADE
PLANTING SOIL
MOUND MIN. 6"
UNDISTURBED OR
COMPACTED SOIL
AFTER EXPOSING TREE ROOT FLAIR,
PLANT SO ROOT FLAIR IS AT 2" ABOVE
ADJACENT FINISH GRADE
NOTES:
- KEEP MULCH APPX. 3" OFF PLANT TRUNK OR STEM
- SEE PLANT SCHEDULE FOR O.C. SPACING, IF APPLICABLE
3X ROOTBALL
DIAMETER
WEST
PREVAILING
WINDS
TREE TIE
SECURED TO
STAKE. SECURE
TO TREE WITH
ANTI-CHAFFING
MATERIAL. ALLOW
FOR MOVEMENT
OF TREE.
(3) TREE
STAKES DRIVEN
A MIN. 2' BELOW
GRADE
PLAN VIEW OF TREE STAKING
NOT TO SCALE
3X R O
O
TBALL
SHREDDED BARK
MULCH
LAWN
FERTILIZER PLANT TAB
FERTILIZER PLANT TAB
- KEEP MULCH APPX. 3" OFF PLANT
TRUNK OR STEM
- SEE PLANT SCHEDULE FOR O.C.
SPACING, IF APPLICABLE
O.C.SPACING
0.
C
SP
AC
IN
G
EDGE OF GROUNDCOVER
AREA/WALK EDGE
1/2 O.C. SPACING
TRIANGULAR SPACE,
AT SPECIFIED O.C.
DISTANCE - EQUIDISTANT
PLANT CENTER
SHREDDED BARK MULCH
ROOTBALL
PLANTING SOIL
NATIVE SOIL
NOTE: RESTORATION SLOPE SHALL NOT BE MORE
THAN 4:1. IF APPLICABLE, ADJUST RESTORATION
DISTANCE TO PROVIDE SLOPE LESS THAN 4:1.
EDGE OF DISTURBANCE
2' MIN.
NEW SOD
6" DEPTH TOPSOIL
EXISTING TURF
6" PREPARED
SUBGRADE
FINISHED GRADE
2"
CAST STONE MASONRY POST; 7-1/2" SQ. X 6'-4"
W/ 1" CHAMFER @ ALL EXPOSED CORNERS &
3/8" RECESSED AREA (4 1/4" X 6-3/4" X 3/8" DP) (2
SIDES PARALLEL TO STEET OR SIDEWALK);
CAST W/ (3) #3 REBAR EQUALLY SPACED, FINISH
AS SPECIFIED
71 4"
SECURE W/ (2) 3/16" X 2" S.S. TAMPER-PROOF
SCREWS & EXPANSION SHIELDS
3' -0
1'-6"
2' -0
BRASS ESCUTCHEON PLATE
CL
TO CENTER
OF RECEPTACLE 1/8" THICK ALUMINUM SIGN PANEL
12" X 22" FIBRELYTE COMPOSITE CONCRETE
VALVE BOX WITH COMPOSITE LID
1'-6"
2' -4
31 8" Flower Vases
TRASH AND VASE
RECEPTACLES
PVC PIPE RISER
8" WASHED ROUND GRAVEL
8" WASHED ROUND GRAVEL
SMOOTH FINISH, SELF
CLOSING BRASS SPIGOT
1' -3
CONCRETE PAVING
SEE 6/CS-501
8" WASHED ROUND GRAVEL
FILTER FABRIC
2" X 1" PVC REDUCER
1" CL 200 PVC PIPE
(LENGTH AS REQUIRED)
3/4" TYPE K COPPER PIPING
HDPE MAINLINE
PIPE & HDPE
ELECTROFUSION
WELD SERVICE TEE
SCH 40 PVC 1-INCH
MALE ADAPTER
BRICK (CONTINUOUS AROUND
BOTTOM OF VALVE BOX
FILTER FABRIC
3" MIN DEPTH OF 34 "
WASHED GRAVEL
4" x 1" COPPER
MALE ADAPTOR
PVC SCH 80 UNION
PVC SCH 80 CLOSE NIPPLE
1" ADJUSTABLE PRESSURE REGULATOR
PVC SCH. 80 NIPPLE
1" THREADED CURB STOP VALVE
SCH 40 PVC REDUCING MALE ADAPTER (1 of 2)
LAWN/ ROCK MULCH
PLANTING BED
BOUNDARY BETWEEN LAWN AND PLANTING AREA OR
ROCK MULCH AND WOOD MULCH, AS SHOWN ON PLAN
STEEL LANDSCAPE EDGING 3/16"
THICK BY 4" DP.
LANDSCAPE EDGING STAKE 16" TO
18" LONG
3" DP. MULCH
LANDSCAPE FABRIC IF SPECIFIED
SPECIFIED PLANTING SOIL
SUBGRADE
6" DEEP SHOVEL
CUT
TREATED 2x4 HEADER ANCHORED TO BACK OF CURB, HELD 1/2" BELOW TOP OF CURB OR CONCRETE WALK.
ANCHORS SHALL BE 1/2"x4" WEDGE ANCHOR SPACED 4FT ON-CENTER.
NEW OR EXISTING CURB
3" SCH 40 PVC OUTLET THROUGH CURB FACE (INVERT AT FLOWLINE)
3" SCH 40 PERFORATED PIPE
SYNTHETIC TURF
3/4" MINUS CRUSHED AGGREGATE BASE
NOTES:
1. SYNTHETIC TURF TO BE SYNTIPEDE X43 MANUFACTURED BY SYNLAWN.
2. INSTALL TREATED 2x4 LUMBER HEADER AT ALL MATCH POINTS WITH CURB OR CONCRETE WALKS FOR SECURING TURF EDGES. TOP OF
HEADER SHALL BE HELD 1/2 INCH BELOW ADJACENT SURFACES.
3. PREPARED SUBGRADE SHALL BE SLOPED TOWARDS LOWPOINT IN CURB FOR DRAINAGE AND PROVIDE FOR A MINIMUM OF 3" OF
CRUSHED AGGREGATE BASE MATERIAL (3.5 INCHES BELOW ADJACENT SURFACES). COMPACT SUBGRADE TO 90% STANDARD PROCTOR.
3. INSTALL DRAIN OUTLET AT LOW POINT. EXTEND PERFORATED PIPE ALONG BACK OF CURB ON EACH SIDE OF OUTLET POINT A MINIMUM
OF 15FT. TERMINATE PERFORATED PIPE WITH SOLID CAP. INSTALL VENT CAP WITH STEEL SCREEN ON OUTLET PIPE. END OF OUTLET
PIPE SHALL BE FLUSH WITH CURB FACE.
4. INSTALL CRUSHED AGGREGATE BASE. GRADE SURFACE TO PROVIDE GENERALLY STRAIGHT GRADE FROM EDGE TO EDGE OF TURF
AREA AND COMPACT TO 90% STANDARD PROCTOR.
5. INSTALL SYNTHETIC TURF ACCORDING TO MANUFACTURER'S INSTRUCTIONS, EXCEPT THAT EDGES OF TURF SHALL BE SECURED TO TREATED LUMBER HEADER WITH 1" LONG STAPLES SPACED 18" ON CENTER. STAPLES SHALL BE INSTALLED SUCH THAT TUFT OF TURF MATERIAL IS NOT AFFECTED. INFILL SYNTHETIC TURF ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
2" FALL PAD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_l
_l an d.
dw at hi el d:
6/
/2
2:
lo t:7
/1 4/
:0
PM
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
LP501
LANDSCAPE
DETAILS
AT MT 74
VICINITY MAP
1 EXISTING WOODEN GUARDRAIL
SCALE: NTS
6 BACK OF CURB RESTORATION
SCALE: NTS4 CURB ISLAND GROUNDCOVER PLANTING
SCALE: NTS3 DECIDUOUS TREE PLANTING
SCALE: NTS
NOTE: EXISTING WOODEN GUARDRAIL SYSTEM TO BE DISASSEMBLED SUCH THAT
IT MAY BE REINSTALLED IN NEW LOCATION. CONTRACTOR TO SUPPLY NECESSARY
LABOR, EQUIPMENT, AND HARDWARE FOR REMOVAL AND REINSTALLATION.
WOODEN POSTS SHALL BE DISPOSED OF AND REPLACED IN KIND.
2 FLOWER WATERING STATION
SCALE: NTS
5 METAL EDGING
SCALE: NTS
7 ROOT BARRIER
SCALE: NTS
NOTES:
1. ROOT BARRIER SHALL BE 0.075" THICK INJECTION MOLDED PANEL MADE OF RECYCLED
POLYPROPYLENE WITH ADDED UV INHIBITOR.
2. PANELS SHALL BE REINFORCED WITH THICKENED TOP EDGE AND INTERMEDIATE VERTICAL
RIBS SPACED EVENLY ON FACE OF PANEL. VERTICAL RIBS ALSO ACT TO DIRECT ROOT
GROWTH VERTICALLY RATHER THAN HORIZONTALLY.
3. PANEL ENDS SHALL HAVE INTEGRAL LOCKING SYSTEM TO FASTEN SEQUENTIAL PANEL
LENGTHS TOGETHER.
NEW OR EXISTING CURB
TOP OF ROCK OR BARK MULCH
INSTALL PANEL SUCH THAT AGGREGATE BASE
EXTENDED BEHIND CURB IS NOT DISTURBED
RIGID PLASTIC
ROOT BARRIER
1A STAMPED CONCRETE PATTERN
SCALE: NTS
CHISELED SLATE TEXTURE
8 SYTHETIC TURF INSTALLATION DETAIL
SCALE: NTS
BARRIER SHALL BE INSTALLED 0.5" PROUD OF SOIL SURFACE
SOIL SURFACE
42"
27"
9 ISLAND PLANTING DETAIL
SCALE: NTS
AEC
MEX
CRUSHED
AGGREGATE
BACKFILL
ROOT BARRIER
Trash
PARKING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_s ig na ge
.d w at hi el d:
6/ 2/
1:
A lo t:7
/1 4/
:1
PM
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT
VICINITY MAP
LS100
SIGNAGE PLAN
AT MT 75
N
0 100' 200'
1 SIGNAGE PLAN - NORTH
SCALE: 1" = 100'
N
0 100' 200'
2 SIGNAGE PLAN - SOUTH
SCALE: 1" = 100'
M
AT
C H
L
IN
E
- S
EE
A
BO
VE
M
AT
C H
L
IN
E
- S
EE
B
EL
O
W
STREET SIGN
PANEL "I"
SEE 3/LS101
EASTERN DRIVE
EAST PORTAL
SECOND DRIVE EAST
WESTERN DRIVE
THIRD DRIVE SOUTH
FOURTH DRIVE SOUTHWEST
FOURTH DRIVE SOUTHEAST
SOUTHEAST LOOP
WEST PORTAL
WESTERN DRIVE
SECOND DRIVE EAST
CABRILLO MEMORIAL DRIVE
NORTHEAST LOOP
STREET SIGN
PANELS "B" & "D"
SEE 3/LS101
STREET SIGN
PANELS "D" & "E"
SEE 3/LS101
STREET SIGN
PANEL "B"
SEE 3/LS101
CABRILLO MEMORIAL DRIVE
STREET SIGN
PANEL C
SEE 3/LS101
STREET SIGN
PANELS "A" & "C"
SEE 3/LS101
STREET SIGN
PANEL "E"
SEE 3/LS101
STREET SIGN
PANEL F
SEE 3/LS101
STREET SIGN
PANELS "A" & "F"
SEE 3/LS101
STREET SIGN
PANEL G
SEE 3/LS101
STREET SIGN
PANELS "G" & "H"
SEE 3/LS101
STREET SIGN
PANELS "A" & "G"
SEE 3/LS101
STREET SIGN
PANEL G
SEE 3/LS101
TEMPORARY CONSTRUCTION SIGNAGE
SEE 3/LS101
AutoCAD SHX Text
ARV
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ARV
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NOTE:
ANY SEAM IN METAL TO BE FLAT SEAM - SEAMS TO BE HORIZONTAL
AND OCCUR BETWEEN LINES OF LETTERING.
ALL LETTERING TO BE PAINTED BLACK
WITH EXCEPTION OF PROJECT TITLE
WHICH IS TO BE BLUE
5"
9" M
AX
1' -0
" M
AX
2" 5"
5"
2"
4' -0
M
IN
3' -0
6"
6' -0
8'-0"
CENTER TO BE WHITE
SURROUNDING
BORDER TO BLUE
BACKGROUND TO BE
PAINTED WHITE
BORDER MEMBER PAINTED BLACK PAINT BORDER
MEMBER BLACK
ENAMEL
OPTIMA BOLD
STYLE 5" HIGH
LETTERING
2"X4" FRAME AND
BRACES IN SAME
PLANE
METAL FACE
WHITE ENAMEL
2"X4" FRAME
AND BRACE IN
BACK
METAL FACE
STRETCH METAL FACE
TIGHT, TURN OVER FRAME
AND SECURE WITH FLAT
HEAD DEFORMED NAILS.
LETTERING TO BE OPTIMA
BOLD STYLE 1 1/2" HIGH TO
BE CENTERED HORIZONTAL
4"X4" POSTS
PAINTED WHITE
ELEVATION SECTION
ON CENTERLINE
TEMPORARY CONSTRUCTION
SIGNS TO BE FIELD LOCATED.
VERIFY LOCATION WITH SOR/COR.
SP24.1
2" 4"
3' -0
VA
R
IE
S 3'
-0
4'-0"
2"
3/
4"
2"
BLUE
BLUE OUTLINE WITH
WHITE INTERIOR
JOINT
BRACING
4"X4" POST
FIN. GRADE
BRACING SEE
CONSTRUCTION
SIGN DETAIL THIS
SHEET
RED
RED
WHITE
BLUE
ELEVATION
WOOD STRIPS
TEMPORARY
CONSTRUCTION SIGNS TO
BE FIELD LOCATED. VERIFY
LOCATION WITH SOR/COR.
SP24.04
PLACEMENT:
1. SIGHT TRIANGLE AT INTERSECTIONS
AND DRIVEWAYS FOR SAFETY
REASONS, SIGNS SHALL NOT BE
PLACED IN THE SIGHT TRIANGLE
(SHADED AREA) WHERE THEY CAN
OBSCURE A DRIVER'S VISION.
2. ENSURE THE LOCATION OF A SIGN
DOES NOT BLOCK A DRIVER’S VISION
OF PEDESTRIANS. NO SIGNS IN THE
SIGHT TRIANGLE APPLIES TO
ROADWAY INTERSECTIONS AS WELL
AS DRIVEWAYS.
3. TRAFFIC REGULATORY SIGNS SUCH
AS STOP, YIELD, STREET, AND
PEDESTRIAN CROSSING ARE AN
EXCEPTION TO THIS RULE.
4. WHEN INSTALLING SIGNS ADJUST
LOCATIONS FOR UTILITIES,
IRRIGATION LINES AND STREET
TREES.
SIGNS SHALL NOT BE INSTALLED IN THIS
AREA EXCEPT TRAFFIC REGULATORY
AND STREET SIGNS
DIRECTIONAL SIGN
BACK OF
CURB (B.O.C.)
BACK OF
CURB (B.O.C.)
BACK OF
CURB (B.O.C.)
SECTION MARKER
TRAFFIC REGULATORY SIGN
STREET SIGN
10'-0"
2' -0
2'
-0
2'-0"
ROADWAY
0"
2"
1/8" ALUMINUM SIGN
PANEL; ALL (4) SIDES
SECURE W/ 3/16" Ø X 2" SS
TAMPER-PROOF SCREWS
AND EXPANSION SHIELDS
CAST STONE MASONRY
POST; RECESS =
ALL SIDES
3" 3'
-0
R
EC
ES
S
AR
EA
9"
4' -0
SECURE W/ 3/16" Ø X 2" SS
TAMPER-PROOF SCREWS
AND EXPANSION SHIELDS
1/4"Ø HOLES TO
RECEIVE SCREWS,
TYP.
1/8" THICK
ALUMINUM SIGN
PANEL; BLACK
BACKGROUND W/
WHITE TEXT, TYP.
2 1/2" HT. LETTERING;
OPTIMA BOLD TYPE
FACE
4"
2' -1
11 2"
1 2"
R1 78 "
3"
FINISHED
GRADE
CONCRETE MOW
COLLAR
POST SETTING PANEL "A" PANEL "B" PANEL "C" PANEL "D" PANEL "E" PANEL "F" PANEL "G" PANEL "H" PANEL "I" PANEL "J"
SIGNAGE DETAILS 1
SCALE:1
TEMPORARY CONSTRUCTION SIGNAGE: SP24.01 & SP24.04
1"- 1'
SCALE:2
SIGNAGE PLACEMENT
1"- 5'
NATIONAL CEMETERY SIGNAGE KEY:
NC - 04 . 02 - B - M1 (A)
PROJECT SIGN PLACARD #
POST STYLE / FAMILY
SIGN CONFIGURATION /
VIEW / LAYOUT
SIGN SIZE (SPECIFIC TO TYPE)
SIGN TYPE
NATIONAL CEMETERY
SIGN DESIGNATION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 n ca fo rt ro se cr an s
- c em et er y ro ad s\
_0 ci vi l\_ c ad fi le s\ _0 sh ee ts
\1
_c
_l s_ de ta ils .d w at hi el d:
6/
/2
2:
lo t:7 /1
4/
:1
PM
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16157
FORT ROSECRANS NATIONAL CEMETERY
ROADS AND SANITARY SEWER
IMPROVEMENTS
892-043/045
06-30-2022
1700 CABRILLO MEMORIAL DRIVE, SAN DIEGO, CA 92106
Date: Dwg. of 100
BID DOCUMENTS
COST ESTIMATING:GEOTECHNICAL :
TERRACON
1421 EDINGER AVE. SUITE C
TUSTIN, CA 92780
949-864-2082
RYAN HANKES
OCMI
6110 EXECUTIVE BLVD, SUITE 200
ROCKVILLE, MD 20852
202-299-0530
TOM STRANDBERG
IRRIGATION :
EC DESIGN GROUP
400 5TH STREET
WEST DES MOINES, IA 50265
515-215-6365
LISA ESSY
MECH/ELEC/PLUMB :
IMEG
623 26TH AVENUE
ROCK ISLAND, IL 61201
309-283-1595
GREG RYCKAERT DSJD
LS101
DSJD 76
SCALE:3
STREET SIGNAGE: NC-06.01-C2
2"=1'-0"
NOTE: PROVIDE PROOF SHEET OF STREET SIGN PANELS FOR COR APPROVAL PRIOR TO FABRICATING.
AutoCAD SHX Text of Veterans Affairs
AutoCAD SHX Text U.S. Department
AutoCAD SHX Text
FORT ROSECRANS NATIONAL CEMETERY ROADS AND SANITARY SEWER IMPROVEMENTS
AutoCAD SHX Text
THIS SPACE FOR CONTRACTOR'S NAME ONE OR TWO LINES AS REQUIRED
AutoCAD SHX Text
DESIGNED AND SUPERVISED BY: DEPARTMENT OF VETERANS AFFAIRS WASHINGTON D.C.
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text
WITHOUT A LOST TIME ACCIDENT
AutoCAD SHX Text 0 0 0
AutoCAD SHX Text
DAYS
AutoCAD SHX Text
HAS WORKED
AutoCAD SHX Text
THIS PROJECT
AutoCAD SHX Text
ON SAFETY
AutoCAD SHX Text in
AutoCAD SHX Text
ZERO
AutoCAD SHX Text Department of Veterans Affairs
AutoCAD SHX Text
THE LIFE YOU SAVE MAY BE YOUR OWN
AutoCAD SHX Text Western Drive
AutoCAD SHX Text Eastern Drive
AutoCAD SHX Text West Portal
AutoCAD SHX Text East Portal
AutoCAD SHX Text Second Drive East
AutoCAD SHX Text Third Drive South
AutoCAD SHX Text Fourth Drive South
AutoCAD SHX Text Southeast Loop
AutoCAD SHX Text Eastern Link Drive
Northeast Loop
2"
3/ 8"
R
EC
ES
S, T
YP
(3
) S
ID
ES
71 2"
1/8" ALUMINUM SIGN PANEL
WELDED TO FRAME; CONTINUOUS
WELDS GROUND SMOOTH
3/16"Ø X 3" SS BOLT & EXPANSION
SHIELD
CAST STONE MASONRY POST;
LIGHT SANDBLAST FINISH
SS WASHER, TYP.
1" SQ. TUBULAR ALUMINUM FRAME (1/8"
WALL THICKNESS), CORNERS MITERED,
WELDED AND GROUND SMOOTH
NEOPRENE WASHER, TYP.
CONTINUOUS WELD, GROUND
SMOOTH
FIELD DRILLED HOLE
EXPANSION SHIELD
8"
SS WASHER, TYP.
1" SQ. TUBULAR ALUMINUM FRAME (1/8"
WALL THICKNESS), CORNERS MITERED,
WELDED AND GROUND SMOOTH
NEOPRENE
WASHER, TYP.
CONTINUOUS WELD, GROUND
SMOOTH
3/16"Ø X 3" SS BOLT AND
EXPANSION SHIELD
CONTINUOUS WELD,
GROUND SMOOTH
FIELD DRILLED HOLE
EXPANSION SHIELD
1/8" ALUMINUM SIGN PANEL
WELDED TO FRAME; CONTINUOUS
WELDS GROUND SMOOTH
CAST STONE MASONRY
POST, TYP.
TEMPORARY CONSTRUCTION
SIGN PANEL MOUNTING
3' -6
" M
IN
6"
4"
VARIES
CONCRETE MOW COLLAR
(1" ABOVE FINISHED GRADE IN
TURF AREA, FLUSH WITH MULCH)
CAST STONE
MASONRY POST
FINISHED GRADE
COMPACTED
AGGREGATE
SUBGRADE
4" TOPSOIL
4"
8" 1
8" 8"
8"
1"
1"
2"
3/ 8"
R
EC
ES
S, T
YP
AL
L
SI
D
ES
71 2"
2"
1" C
H
AM
FE
R
, T
YP
(A
LL
E
D G
ES
71 2"
1"
8"
2"
2"
TOP ELEVATION
SECTION PLAN VIEW
CAST STONE MASONRY POST
WITH 1" CHAMFER ON ALL SIDES
& TOP; LIGHT SANDBLAST FINISH
NOTE:
SEE INDIVIDUAL SIGN TYPE
DETAILS FOR 38" RECESS HEIGHT
AND LOCATION ON OVERALL POST
(3) #3 EQUALLY
SPACED REBAR
CAST STONE
MASONRY POST;
LIGHT SANDBLAST
FINISH
CAST STONE
MASONRY POST;
LIGHT SANDBLAST
FINISH
8" RECESS (BELOW);
ALL SIDES
PLAN
ELEVATION
8…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .